MIB Viewer

Jetnet5010G

585 objects
The MIB module for Korenix Industrial Web-Managed Ethernet Rail Switch
OIDNameAccessStatusDescription
1.3.6.1.4Nodeprivate
1.3.6.1.4.1Nodeenterprises
1.3.6.1.4.1.24062Nodekorenix
1.3.6.1.4.1.24062.1IdentitycontactThe MIB module for Korenix Industrial Web-Managed Ethernet Rail Switch
1.3.6.1.4.1.24062.2Nodeproducts
1.3.6.1.4.1.24062.2.2NodemanagedFESwitch
1.3.6.1.4.1.24062.2.2.1Nodejetnet5010G
1.3.6.1.4.1.24062.2.2.1.1NodesystemInfo
1.3.6.1.4.1.24062.2.2.1.1.1ScalarsystemNameread-onlycurrentAn administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name.
1.3.6.1.4.1.24062.2.2.1.1.2ScalarsystemLocationread-onlycurrentThe physical location of this node (e.g., telephone closet, 3rd floor').
1.3.6.1.4.1.24062.2.2.1.1.3ScalarsystemContactread-onlycurrentThe textual identification of the contact person for this managed node, together with information on how to contact this person.
1.3.6.1.4.1.24062.2.2.1.1.4ScalarsystemDescrread-onlycurrentA textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-syste…
1.3.6.1.4.1.24062.2.2.1.1.5ScalarsystemFwVerread-onlycurrentFirmware version of the device.
1.3.6.1.4.1.24062.2.2.1.1.6ScalarsystemMacAddressread-onlycurrentThe MAC address of this device. An Media Access Control address (MAC address) is a unique identifier attached to most network adapters (NICs). It is a number t…
1.3.6.1.4.1.24062.2.2.1.2NodebasicSetting
1.3.6.1.4.1.24062.2.2.1.2.1NodeswitchSetting
1.3.6.1.4.1.24062.2.2.1.2.1.1ScalarswitchSettingSystemNameread-writecurrentAn administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name.
1.3.6.1.4.1.24062.2.2.1.2.1.2ScalarswitchSettingSystemLocationread-writecurrentThe physical location of this node (e.g., telephone closet, 3rd floor').
1.3.6.1.4.1.24062.2.2.1.2.1.3ScalarswitchSettingSystemContactread-writecurrentThe textual identification of the contact person for this managed node, together with information on how to contact this person.
1.3.6.1.4.1.24062.2.2.1.2.2NodeadminPassword
1.3.6.1.4.1.24062.2.2.1.2.2.1ScalaradminPasswordUserNameread-writecurrentThe name(ID) of security manager.
1.3.6.1.4.1.24062.2.2.1.2.2.2ScalaradminPasswordPasswordwrite-onlycurrentThe password of security manager. This object can't be read. it's write-only.
1.3.6.1.4.1.24062.2.2.1.2.3NodeipConfiguration
1.3.6.1.4.1.24062.2.2.1.2.3.1TableipConfigurationTablenot-accessiblecurrentTable of descriptive information and configuration about the IP of the device.
1.3.6.1.4.1.24062.2.2.1.2.3.1.1RowipConfigurationEntrynot-accessiblecurrentInformation configuring static IP or DHCP configuration of the device.
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.1ColumnipConfigurationIndexnot-accessiblecurrentThis object identifies IP configuration entries.
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.2ColumnipConfigurationDHCPStatusread-writecurrentParameter configuring DHCP client functionality of the device. When enabled, device will be a DHCP client and request for the IP configuration from DHCP server…
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.3ColumnipConfigurationAddressread-writecurrentThe IP address of switch. An IP address (Internet Protocol address) is a unique address that devices use in order to identify and communicate with each other o…
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.4ColumnipConfigurationSubMaskread-writecurrentThe subnet mask is a 32-bit number in the same format and representation as IP addresses. The subnet mask determines which bits in the IP address are interpret…
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.5ColumnipConfigurationGatewayread-writecurrentThe default gateway IP address identifies the gateway (for example, a router) that receives and forwards those packets whose addresses are unknown to the local…
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.6ColumnipConfigurationDNS1read-writecurrentParameter configuring the first DNS server of the device. The domain name system (DNS) stores and associates many types of information with domain names. Most …
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.7ColumnipConfigurationDNS2read-writecurrentParameter configuring the second DNS server of the device.
1.3.6.1.4.1.24062.2.2.1.2.3.1.1.8ColumnipConfigurationStatusread-createcurrentThe status of the IP configuration entry. Only one configuration entry is supported on the device. Set active(1) to activate the parameters of the entry on the…
1.3.6.1.4.1.24062.2.2.1.2.4NodetimeSetting
1.3.6.1.4.1.24062.2.2.1.2.4.1ScalarsystemTimeread-onlycurrentcurrent system time in format yyyy.mm.dd-hh:mm:ss
1.3.6.1.4.1.24062.2.2.1.2.4.2ScalarutcTimeZoneread-writecurrentUTC Timezone list. (GMT-12:00) Eniwetok, Kwajalein (GMT-11:00) Midway Island, Samoa (GMT-10:00) Hawaii (GMT-09:00) Alaska (GMT-08:00) Pacific Time (US & Canada…
1.3.6.1.4.1.24062.2.2.1.2.4.3NodedayLightSavingTime
1.3.6.1.4.1.24062.2.2.1.2.4.3.1ScalardaylightSavingTimeStartread-writecurrentThe start-time of daylight saveing period, in format mm.n.d/hh:mm m is month, valid range 1-12 (1=January, 2=February, ..., 12=December). n is week of the mont…
1.3.6.1.4.1.24062.2.2.1.2.4.3.2ScalardaylightSavingTimeEndread-writecurrentThe end-time of daylight saveing period, in format mm.n.d/hh:mm m is month, valid range 1-12 (1=January, 2=February, ..., 12=December). n is week of the month …
1.3.6.1.4.1.24062.2.2.1.2.4.3.3ScalardaylightSavingOffsetread-writecurrentDaylight Saving Offset(Usually is 60 mins). When Enable and current time at Daylight Saving Period, the current time of the switch will be offseted by Daylight…
1.3.6.1.4.1.24062.2.2.1.2.4.3.4ScalardaylightSavingTimeStatusread-writecurrent(1)Enable Daylight Saving Time. (2)Disable Daylight Saving Time. Daylight Saving Time: Use this OID to Enable/Disable Daylight Saving Time.
1.3.6.1.4.1.24062.2.2.1.2.4.4NodeclockSource
1.3.6.1.4.1.24062.2.2.1.2.4.4.1ScalarclockSourceSelectionread-writecurrent.
1.3.6.1.4.1.24062.2.2.1.2.4.4.2NodeclockSourceManual
1.3.6.1.4.1.24062.2.2.1.2.4.4.2.1ScalarclockSourceManualSettingread-writecurrentset system time, in format yyyy.mm.dd-hh:mm:ss
1.3.6.1.4.1.24062.2.2.1.2.4.4.3NodeclockSourceNtp
1.3.6.1.4.1.24062.2.2.1.2.4.4.3.1TablentpTablenot-accessiblecurrentTable of descriptive information and configuration about NTP servers. NTP (Network Time Protocol) synchronizes timekeeping among a set of distributed time serv…
1.3.6.1.4.1.24062.2.2.1.2.4.4.3.1.1RowntpEntrynot-accessiblecurrentInformation configuring IP addresses of NTP servers.
1.3.6.1.4.1.24062.2.2.1.2.4.4.3.1.1.1ColumnntpIndexnot-accessiblecurrentThis object identifies the entry.
1.3.6.1.4.1.24062.2.2.1.2.4.4.3.1.1.2ColumnntpServerIPread-writecurrentThe IP address of an NTP Server. Set 0.0.0.0 or 255.255.255.255 to remove this config.
1.3.6.1.4.1.24062.2.2.1.2.5NodedhcpServer
1.3.6.1.4.1.24062.2.2.1.2.5.1ScalardhcpServerEnableread-writecurrentEnable or disable dhcp server function.
1.3.6.1.4.1.24062.2.2.1.2.5.2TabledhcpServerPoolTablenot-accessiblecurrentTable of descriptive information and configuration about DHCP server of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1RowdhcpServerPoolEntrynot-accessiblecurrentAn entry containing DHCP server information of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1.1ColumndhcpServerPoolIndexnot-accessiblecurrentThe index of the Address Pool.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1.2ColumndhcpServerPoolNameread-onlycurrentThe address pool name.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1.3ColumndhcpServerPoolNetworkread-writecurrentThe Subnet of the IP Address Pool.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1.4ColumndhcpServerPoolSubMaskread-writecurrentThe subnet mask of the IP Address Pool.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1.5ColumndhcpServerPoolGatewayread-writecurrentThe gateway address of the IP Address Pool.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1.6ColumndhcpServerPoolLeaseTimeread-writecurrentThe lease time(in second) of the Address Pool.
1.3.6.1.4.1.24062.2.2.1.2.5.2.1.7ColumndhcpServerPoolStatusread-createcurrentThe status of the Address Pool.
1.3.6.1.4.1.24062.2.2.1.2.5.3TabledhcpExcludedTablenot-accessiblecurrentTable of descriptive information and configuration about DHCP server of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.3.1RowdhcpExcludedEntrynot-accessiblecurrentAn entry containing DHCP server information of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.3.1.1ColumndhcpExcludedIndexnot-accessiblecurrentThe index of the Excluded Table.
1.3.6.1.4.1.24062.2.2.1.2.5.3.1.2ColumndhcpExcludedIpread-writecurrentThe IP address .
1.3.6.1.4.1.24062.2.2.1.2.5.3.1.3ColumndhcpExcludedStatusread-createcurrentThe status of a address pool.
1.3.6.1.4.1.24062.2.2.1.2.5.4TabledhcpManualBindingTablenot-accessiblecurrentTable of descriptive information and configuration about DHCP server of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.4.1RowdhcpManualBindingEntrynot-accessiblecurrentAn entry containing DHCP server information of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.4.1.1ColumndhcpManualBindingIndexnot-accessiblecurrentThe index of the Static Binding Table.
1.3.6.1.4.1.24062.2.2.1.2.5.4.1.2ColumndhcpManualBindingIpread-writecurrentThe IP address.
1.3.6.1.4.1.24062.2.2.1.2.5.4.1.3ColumndhcpManualBindingMacread-writecurrentThe MAC address.
1.3.6.1.4.1.24062.2.2.1.2.5.4.1.4ColumndhcpManualBindingStatusread-createcurrentThe status of the binding.
1.3.6.1.4.1.24062.2.2.1.2.5.5TabledhcpStaticPortTablenot-accessiblecurrentTable of descriptive information and configuration about DHCP server of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.5.1RowdhcpStaticPortEntrynot-accessiblecurrentAn entry containing DHCP server information of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.5.1.1ColumndhcpStaticPortIndexnot-accessiblecurrentThe index of the StaticPort Table.
1.3.6.1.4.1.24062.2.2.1.2.5.5.1.2ColumndhcpStaticPortNumberread-writecurrentThe port number .
1.3.6.1.4.1.24062.2.2.1.2.5.5.1.3ColumndhcpStaticPortIpread-writecurrentThe IP address .
1.3.6.1.4.1.24062.2.2.1.2.5.5.1.4ColumndhcpStaticPortStatusread-createcurrentThe status of a static port entry.
1.3.6.1.4.1.24062.2.2.1.2.5.6TabledhcpOption82Tablenot-accessiblecurrentDHCP server option82 table.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1RowdhcpOption82Entrynot-accessiblecurrentDHCP server option82 entry.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1.1ColumndhcpOption82Indexnot-accessiblecurrentThe index of the table.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1.2ColumndhcpOption82CircuitIdTyperead-writecurrentThe Circuit-ID type of this option.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1.3ColumndhcpOption82CircuitIdValueread-writecurrentThe Circuit-ID value of this option.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1.4ColumndhcpOption82RemoteIdTyperead-writecurrentThe Remote-ID type of this option.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1.5ColumndhcpOption82RemoteIdValueread-writecurrentThe Remote-ID value of this option.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1.6ColumndhcpOption82Ipread-writecurrentThe IP Address bind to this option.
1.3.6.1.4.1.24062.2.2.1.2.5.6.1.7ColumndhcpOption82Statusread-createcurrenthe status of a static port entry.
1.3.6.1.4.1.24062.2.2.1.2.5.7TabledhcpServerLeasedTablenot-accessiblecurrentTable of descriptive information and configuration about DHCP server of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.7.1RowdhcpServerLeasedEntrynot-accessiblecurrentAn entry containing DHCP server information of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.7.1.1ColumndhcpServerLeasedIndexnot-accessiblecurrentThe index of the Leased Table.
1.3.6.1.4.1.24062.2.2.1.2.5.7.1.2ColumndhcpServerLeasedIpread-onlycurrentThe client IP address.
1.3.6.1.4.1.24062.2.2.1.2.5.7.1.3ColumndhcpServerLeasedMacread-onlycurrentThe client MAC address.
1.3.6.1.4.1.24062.2.2.1.2.5.7.1.4ColumndhcpServerLeasedTyperead-onlycurrent.
1.3.6.1.4.1.24062.2.2.1.2.5.7.1.5ColumndhcpServerLeasedTimeread-onlycurrentThe lease time of the client.
1.3.6.1.4.1.24062.2.2.1.2.5.8ScalardhcpRelayAgentEnableread-writecurrentEnable or disable dhcp relay agent function.
1.3.6.1.4.1.24062.2.2.1.2.5.9ScalardhcpRelayAgentPolicyread-writecurrentKeep(1): Keeps the original option 82 field and forwards to server drop(2): Drops the option 82 field and do not add any option 82 field replace(3): Replaces t…
1.3.6.1.4.1.24062.2.2.1.2.5.10TabledhcpRelayAgentCircuitIdTablenot-accessiblecurrentDescription.
1.3.6.1.4.1.24062.2.2.1.2.5.10.1RowdhcpRelayAgentCircuitIdEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.24062.2.2.1.2.5.10.1.1ColumndhcpRelayAgentCircuitIdPortNumread-onlycurrentDescription.
1.3.6.1.4.1.24062.2.2.1.2.5.10.1.2ColumndhcpRelayAgentCircuitIdTyperead-writecurrentCircuit-ID type of the Option82 added by Relay Agent.
1.3.6.1.4.1.24062.2.2.1.2.5.10.1.3ColumndhcpRelayAgentCircuitIdValueread-writecurrentCircuit-ID value of the Option82 added by Relay Agent, the format can be String or Hexadecimal value.
1.3.6.1.4.1.24062.2.2.1.2.5.10.1.4ColumndhcpRelayAgentCircuitIdDisplayread-onlycurrentDisplay the Circuit-ID value by Hexadecimal format
1.3.6.1.4.1.24062.2.2.1.2.5.11ScalardhcpRelayAgentRemoteIdTyperead-writecurrentRemote-ID type of the Option82 added by Relay Agent.
1.3.6.1.4.1.24062.2.2.1.2.5.12ScalardhcpRelayAgentRemoteIdValueread-writecurrentRemote-ID value of the Option82 added by Relay Agent, the format can be String or Hexadecimal value.
1.3.6.1.4.1.24062.2.2.1.2.5.13ScalardhcpRelayAgentRemoteIdDisplayread-writecurrentRemote-ID value of the Option82 added by Relay Agent.
1.3.6.1.4.1.24062.2.2.1.2.5.14TabledhcpHelperAddressTablenot-accessiblecurrentTable of descriptive information and configuration about DHCP relay helper address of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.14.1RowdhcpHelperAddressEntrynot-accessiblecurrentAn entry containing DHCP relay information of the switch.
1.3.6.1.4.1.24062.2.2.1.2.5.14.1.1ColumndhcpHelperAddressread-writecurrentThe IP address .
1.3.6.1.4.1.24062.2.2.1.2.6NodebackupAndRestore
1.3.6.1.4.1.24062.2.2.1.2.6.1ScalarbackupServerIPread-writecurrentThe IP address of a TFTP server to which a startup configuration can be uploaded.
1.3.6.1.4.1.24062.2.2.1.2.6.2ScalarbackupAgentBoardFwFileNameread-writecurrentThe filename to backup to.
1.3.6.1.4.1.24062.2.2.1.2.6.3ScalarbackupStatusread-writecurrentSetting this object to active(1) trigger the TFTP upload action. Setting this object to notActive(2) has no effect. The system always returns the value notActi…
1.3.6.1.4.1.24062.2.2.1.2.6.4ScalarrestoreServerIPread-writecurrentThe IP address of a TFTP server from which the startup configuration can be downloaded.
1.3.6.1.4.1.24062.2.2.1.2.6.5ScalarrestoreAgentBoardFwFileNameread-writecurrentThe file name to restore from.
1.3.6.1.4.1.24062.2.2.1.2.6.6ScalarrestoreStatusread-writecurrentSetting this object to active(1) trigger the TFTP download action. Setting this object to notActive(2) has no effect. The system always returns the value notAc…
1.3.6.1.4.1.24062.2.2.1.2.7NodetftpUpgrade
1.3.6.1.4.1.24062.2.2.1.2.7.1ScalartftpDownloadServerIPread-writecurrentThe IP address of a TFTP server where a firmware image can be downloaded.
1.3.6.1.4.1.24062.2.2.1.2.7.2ScalartftpDownloadAgentBoardFwFileNameread-writecurrentThe file name of the firmware to be downloaded.
1.3.6.1.4.1.24062.2.2.1.2.7.3ScalartftpDownloadStatusread-writecurrentSetting this object to active(1) trigger the TFTP download action. Setting this object to notActive(2) has no effect. The system always returns the value notAc…
1.3.6.1.4.1.24062.2.2.1.2.8NodefactoryDefault
1.3.6.1.4.1.24062.2.2.1.2.8.1ScalarfactoryDefaultActiveread-writecurrentSet to active(1) to reload factory default configuration. Reloading factory default will overwrite your current configuration file with factocy default configu…
1.3.6.1.4.1.24062.2.2.1.2.9NodesystemReboot
1.3.6.1.4.1.24062.2.2.1.2.9.1ScalarsystemRebootActiveread-writecurrentSet active(1) to restart the device. Set to notActive(2) has no effect. The device always returns the value notActive(2) when this object is read.
1.3.6.1.4.1.24062.2.2.1.3NodeportConfiguration
1.3.6.1.4.1.24062.2.2.1.3.1NodeportControl
1.3.6.1.4.1.24062.2.2.1.3.1.1TableportCtrlTablenot-accessiblecurrentTable of information and configuration for each ports.
1.3.6.1.4.1.24062.2.2.1.3.1.1.1RowportCtrlEntrynot-accessiblecurrentAn entry containing information and configuration for a port.
1.3.6.1.4.1.24062.2.2.1.3.1.1.1.1ColumnportCtrlIndexnot-accessiblecurrentIndex of the port control entry.
1.3.6.1.4.1.24062.2.2.1.3.1.1.1.2ColumnportCtrlPortNameread-onlycurrentThe name of port.
1.3.6.1.4.1.24062.2.2.1.3.1.1.1.3ColumnportCtrlPortStatusread-writecurrentTo enable or disable of this port.
1.3.6.1.4.1.24062.2.2.1.3.1.1.1.4ColumnportCtrlSpeedAndDuplexread-writecurrentSpeed and duplex configuraion. Different speed and duplex modes are available. There are speeds: 1000 megabits per second (Gigabit Ethernet), 100 megabits per …
1.3.6.1.4.1.24062.2.2.1.3.1.1.1.5ColumnportCtrlFlowControlread-writecurrentFlow control configuration. Flow control is used to throttle the throughput rate of an end station to avoid dropping packets during network congestion. If flow…
1.3.6.1.4.1.24062.2.2.1.3.1.1.1.6ColumnportCtrlPortDescriptionread-writecurrentThe description of port.
1.3.6.1.4.1.24062.2.2.1.3.2NodeportStatus
1.3.6.1.4.1.24062.2.2.1.3.2.1TableportStatusTablenot-accessiblecurrentTable of descriptive and statistics information about each ports.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1RowportStatusEntrynot-accessiblecurrentAn entry containing statistics information of a port.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.1ColumnportStatusIndexread-onlycurrentIndex of port statistic table.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.2ColumnportStatusTyperead-onlycurrentIndicates the type of the port.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.3ColumnportStatusLinkread-onlycurrentIndicate the link state of the port.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.4ColumnportStatusStateread-onlycurrentIndicate the state of the port.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.5ColumnportStatusSpeedDuplexread-onlycurrentIndicate the speed and duplex mode of the port.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.6ColumnportStatusFlowCtrlread-onlycurrentIndicate the flow control status of the port.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.7ColumnsfpVenderread-onlycurrentThe vender name of the Small Form Pluggable (SFP) optical transceiver module.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.8ColumnsfpWavelengthread-onlycurrentThe wave length in nanometers (nm) of the Small Form Pluggable (SFP) optical transceiver module.
1.3.6.1.4.1.24062.2.2.1.3.2.1.1.9ColumnsfpDistanceread-onlycurrentThe maximum transimission distance in meters of the Small Form Pluggable (SFP) optical transceiver module.
1.3.6.1.4.1.24062.2.2.1.3.2.2TableportSfpTablenot-accessiblecurrentTable of descriptive information about SFP
1.3.6.1.4.1.24062.2.2.1.3.2.2.1RowportSfpEntrynot-accessiblecurrentAn entry containing SFP information of a port.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.1ColumnportSfpIndexread-onlycurrentIndex of port SFP table.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.2ColumnportSfpEjectread-writecurrentEject SFP
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.3ColumnportSfpScanread-writecurrentScan SFP
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.4ColumnportSfpDdmStatusread-writecurrent(1)Enable SFP digital diagnostic and monitoring. (2)Disable SFP digital diagnostic and monitoring.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.5ColumnportSfpDdmTempatureCurrentread-onlycurrentThe current SFP Tempature of port.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.6ColumnportSfpDdmTempatureRangeread-onlycurrentThe range of SFP Tempature of port.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.7ColumnportSfpDdmTxPowerCurrentread-onlycurrentThe current SFP Transmitted Power of port.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.8ColumnportSfpDdmTxPowerRangeread-onlycurrentThe range of SFP Transmitted Power of port.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.9ColumnportSfpDdmRxPowerCurrentread-onlycurrentThe current SFP Receiveed Power of port.
1.3.6.1.4.1.24062.2.2.1.3.2.2.1.10ColumnportSfpDdmRxPowerRangeread-onlycurrentThe range of SFP Receiveed Power of port.
1.3.6.1.4.1.24062.2.2.1.3.2.3ScalarportSfpEjectAllread-writecurrentEject all SFP
1.3.6.1.4.1.24062.2.2.1.3.2.4ScalarportSfpScanAllread-writecurrentScan all SFP
1.3.6.1.4.1.24062.2.2.1.3.3NoderateLimiting
1.3.6.1.4.1.24062.2.2.1.3.3.1TablerateLimitingTablenot-accessiblecurrentTable of descriptive information and configuration about port rate limiting. You can set up bandwidth rate and packet limitation type for each ports. Rate limi…
1.3.6.1.4.1.24062.2.2.1.3.3.1.1RowrateLimitingEntrynot-accessiblecurrentAn entry containing information and configuration about port rate limiting.
1.3.6.1.4.1.24062.2.2.1.3.3.1.1.1ColumnrateLimitingPortNumread-onlycurrentThe port number.
1.3.6.1.4.1.24062.2.2.1.3.3.1.1.2ColumnrateLimitingIngressLimitTyperead-writecurrentThe type of ingress packets to be filtered.
1.3.6.1.4.1.24062.2.2.1.3.3.1.1.3ColumnrateLimitingIngressRateread-writecurrentIngress rate in Mbps, the rate range is from 1 Mbps to 100 Mbps and zero means no limit.
1.3.6.1.4.1.24062.2.2.1.3.3.1.1.4ColumnrateLimitingEgressRateread-writecurrentEgress rate in Mbps, the rate range is from 1 Mbps to 100 Mbps and zero means no limit. Egress rate limiting has effect on all types of packets, including unic…
1.3.6.1.4.1.24062.2.2.1.3.4NodeportTrunk
1.3.6.1.4.1.24062.2.2.1.3.4.1NodeaggregatorSetting
1.3.6.1.4.1.24062.2.2.1.3.4.1.1TableportTrunkAggregatorSettingTablenot-accessiblecurrentTable of descriptive information and configuration about of each trunk group in this system. Link aggregation, or IEEE 802.3ad, is a method of combining physic…
1.3.6.1.4.1.24062.2.2.1.3.4.1.1.1RowportTrunkAggregatorSettingEntrynot-accessiblecurrentInformation controlling aggregator configuration.
1.3.6.1.4.1.24062.2.2.1.3.4.1.1.1.1ColumnportTrunkPortIndexread-onlycurrentThe port number.
1.3.6.1.4.1.24062.2.2.1.3.4.1.1.1.2ColumnportTrunkAggregatorGroupIdread-writecurrentTrunk group Id. Upto 8 ports can be aggregated into a group and 5 groups can be configured in the device.
1.3.6.1.4.1.24062.2.2.1.3.4.1.1.1.3ColumnportTrunkAggregatorTyperead-writecurrentThe Aggregator type. You can assign the aggregator staticly by setting to static(1), or setting to lacp(2) to enable the LACP protocol. The Link Aggregation Co…
1.3.6.1.4.1.24062.2.2.1.3.4.1.2ScalarportTrunkAggregatorSettingApplyread-writecurrentset active(1) to apply the configuration
1.3.6.1.4.1.24062.2.2.1.3.4.2NodeaggregatorStatus
1.3.6.1.4.1.24062.2.2.1.3.4.2.1TableportTrunkAggregatorStatusTablenot-accessiblecurrentTable of descriptive information about trunk groups in the device.
1.3.6.1.4.1.24062.2.2.1.3.4.2.1.1RowportTrunkAggregatorStatusEntrynot-accessiblecurrentAn entry containing information about current configuration of trunk groups.
1.3.6.1.4.1.24062.2.2.1.3.4.2.1.1.1ColumnportTrunkAggregatorGroupIndexread-onlycurrentThe trunk group identifier.
1.3.6.1.4.1.24062.2.2.1.3.4.2.1.1.2ColumnportTrunkAggregatorGroupTyperead-onlycurrentThe Aggregator type. (1) The trunk group is LACP disabled and configured staticly by administrator. (2) The trunk group is LACP enabled.
1.3.6.1.4.1.24062.2.2.1.3.4.2.1.1.3ColumnportTrunkAggregatorGroupMemberread-onlycurrentThe ports are aggregated with other ports.
1.3.6.1.4.1.24062.2.2.1.3.4.2.1.1.4ColumnportTrunkAggregatorIndividualread-onlycurrentA port is LACP enabled but not aggregated with other ports.
1.3.6.1.4.1.24062.2.2.1.3.4.2.1.1.5ColumnportTrunkAggregatorLinkDownread-onlycurrentThe ports which are linked down.
1.3.6.1.4.1.24062.2.2.1.4NodenetworkRedundancy
1.3.6.1.4.1.24062.2.2.1.4.4NodemultipleSuperRing
1.3.6.1.4.1.24062.2.2.1.4.4.1TablemultipleSuperRingConfigTablenot-accessiblecurrentTable of configuration about redundany protocol in the device.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1RowmultipleSuperRingConfigEntrynot-accessiblecurrentAn entry containing information about current configuration of rings.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.1ColumnsuperRingConfigIdnot-accessiblecurrentRing Id.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.2ColumnsuperRingNameread-writecurrentSuper Ring name.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.3ColumnsuperRingConfigVersionread-writecurrentSuper Ring funtion version selection. Super Ring: Backward compatible with legacy super ring mechanism. Note: This model supports v1 non-Redundancy Management …
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.4ColumnsuperRingDevicePriorityread-writecurrentSuper Ring device priority setting.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.5ColumnsuperRingRingPort1read-writecurrentRingPort1 should not equal to RingRort2.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.6ColumnsuperRingRingPort2read-writecurrentRingPort2 should not equal to RingRort1.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.7ColumnsuperRingRingPort1PathCostread-writecurrent
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.8ColumnsuperRingRingPort2PathCostread-writecurrent
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.9ColumnsuperRingRapidDualHomingStatusread-writecurrentRapid Dual Homing funtion status. Rapid Dual Homing is a redundancy protocol, which is compatible with RSTP. (1) Rapid Dual Homing function is enabled. (2) Rap…
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.10ColumnsuperRingStatusread-createcurrentStatus of this ring.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.11ColumnsuperChainStatusread-writecurrentStatus of this chain.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.12ColumnsuperChainEdgePortread-writecurrentEdgePort of the chain.
1.3.6.1.4.1.24062.2.2.1.4.4.1.1.13ColumnsuperRingRapidDualHomingExtensionIdread-writecurrentRapid Dual Homing Extension ID. The Extension ID and Ring ID cannot be the same, when dual home to the same foreing network. The Extension ID range from 0 to 7…
1.3.6.1.4.1.24062.2.2.1.4.4.2TablemultipleSuperRingStatusTablenot-accessiblecurrentTable of status information about redundany protocol in the device.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1RowmultipleSuperRingStatusEntrynot-accessiblecurrentAn entry containing information about current status of rings.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.1ColumnsuperRingStatusIdread-onlycurrentRing Id.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.2ColumnsuperRingVersionread-onlycurrentSuper Ring funtion version selection. Super Ring: Backward compatible with legacy super ring mechanism. Note: This model supports v1 non-Redundancy Management …
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.3ColumnsuperRingDeviceRoleread-onlycurrentSuper Ring role status. (1) disabled. (2) Redundancy manager. (3) Non redundancy manager.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.4ColumnsuperRingRingPortList1read-onlycurrentPort list for ring port1.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.5ColumnsuperRingRingPortList2read-onlycurrentPort list for ring port2.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.6ColumnsuperRingRingStatusread-onlycurrentSuper Ring ring status. (1) Disabled - The ring on this device is disabled. (1) Normal - Ring is complete. (2) Abnormal - Ring is not complete.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.7ColumnsuperRingRmMacread-onlycurrentRM mac address.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.8ColumnsuperRingBlockedPortread-onlycurrentThe blocked ports in ring Normal state.
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.9ColumnsuperRingRoleTransitionCountread-onlycurrent
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.10ColumnsuperRingRingStateTransitionCountread-onlycurrent
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.11ColumnsuperChainRoleread-onlycurrent
1.3.6.1.4.1.24062.2.2.1.4.4.2.1.12ColumnsuperChainEdgePortListread-onlycurrentEdge Port list for SuperChain.
1.3.6.1.4.1.24062.2.2.1.4.5Nodestp
1.3.6.1.4.1.24062.2.2.1.4.5.1ScalarstpModeStatusread-writecurrentEnable Spanning Tree protocol, Rapid Spanning Tree protocol, or disable . Rapid Spanning Tree Algorithm and Protocol (RSTP) provides a loop free topology for a…
1.3.6.1.4.1.24062.2.2.1.4.5.2ScalarstpBridgeAddressread-onlycurrentBridge Address.
1.3.6.1.4.1.24062.2.2.1.4.5.3ScalarstpBridgePriorityread-writecurrentA value used to identify the root bridge. The bridge with the lowest value has the highest priority and is selected as the root. Enter a number 0 through 61440…
1.3.6.1.4.1.24062.2.2.1.4.5.4ScalarstpMaxAgeread-writecurrentThe number of seconds a bridge waits without receiving Spanning-Tree Protocol configuration messages before attempting a reconfiguration. Enter a number 6 thro…
1.3.6.1.4.1.24062.2.2.1.4.5.5ScalarstpHelloTimeread-writecurrentThe number of seconds between the transmission of Spanning-Tree Protocol configuration messages. Enter a number 1 through 10 Note: 2*(Forward Delay Time-1) sho…
1.3.6.1.4.1.24062.2.2.1.4.5.6ScalarstpForwardDelayTimeread-writecurrentThe number of seconds a port waits before changing from its Spanning-Tree Protocol learning and listening states to the forwarding state. Enter a number 4 thro…
1.3.6.1.4.1.24062.2.2.1.4.5.7TablestpPerPortCfgTablenot-accessiblecurrentTable of descriptive information and configuration about STP on each port.
1.3.6.1.4.1.24062.2.2.1.4.5.7.1RowstpPerPortCfgEntrynot-accessiblecurrentInformation configuring STP on a port.
1.3.6.1.4.1.24062.2.2.1.4.5.7.1.1ColumnstpPerPortCfgPortNumnot-accessiblecurrentThe port number.
1.3.6.1.4.1.24062.2.2.1.4.5.7.1.2ColumnstpPerPortCfgStpStateread-writecurrentEnable/Disable STP/RSTP/MSTP at this port. Disable STP state when connecting a device in order to avoid STP waiting periods.
1.3.6.1.4.1.24062.2.2.1.4.5.7.1.3ColumnstpPerPortCfgPathCostread-writecurrentThe cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number from 1 through 200000000. (0 will auto set path co…
1.3.6.1.4.1.24062.2.2.1.4.5.7.1.4ColumnstpPerPortCfgPriorityread-writecurrentDecide which port should be blocked by priority in LAN. Enter a number from 0 through 240 in steps of 16.
1.3.6.1.4.1.24062.2.2.1.4.5.7.1.5ColumnstpPerPortCfgLinkTyperead-writecurrentSome of the rapid state transactions that are possible within RSTP are dependent upon whether the Port concerned can only be connected to exactly one other Bri…
1.3.6.1.4.1.24062.2.2.1.4.5.7.1.6ColumnstpPerPortCfgEdgePortread-writecurrentPresent in implementations that support the identification of edge ports. All ports directly connected to end stations cannot create bridging loops in the netw…
1.3.6.1.4.1.24062.2.2.1.4.6NodestpBridgeInformation
1.3.6.1.4.1.24062.2.2.1.4.6.1TablestpRootInformationTablenot-accessiblecurrentTable of descriptive information about root bridge of rapid spanning tree in this system.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1RowstpRootInformationEntrynot-accessiblecurrentAn entry in the table, containing information about root bridge information of the STP.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.1ColumnstpRootInformationIndexnot-accessiblecurrentIndex of root bridge information table.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.2ColumnstpRootInformationRootAddressread-onlycurrentRoot Address.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.3ColumnstpRootInformationRootPriorityread-onlycurrentRoot Priority.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.4ColumnstpRootInformationRootPortread-onlycurrentRoot Port.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.5ColumnstpRootInformationRootPathCostread-onlycurrentRoot Path Cost.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.6ColumnstpRootInformationMaxAgeread-onlycurrentMax Age.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.7ColumnstpRootInformationHelloTimeread-onlycurrentHello Time.
1.3.6.1.4.1.24062.2.2.1.4.6.1.1.8ColumnstpRootInformationForwardDelayread-onlycurrentForward Delay Time.
1.3.6.1.4.1.24062.2.2.1.4.6.2TablestpPerPortInfoTablenot-accessiblecurrentTable of descriptive information and configuration about rapid spanning tree (Per port).
1.3.6.1.4.1.24062.2.2.1.4.6.2.1RowstpPerPortInfoEntrynot-accessiblecurrentAn entry in the table, containing inforamtion about STP (Per port).
1.3.6.1.4.1.24062.2.2.1.4.6.2.1.1ColumnstpPerPortInfoPortNumnot-accessiblecurrentPort number.
1.3.6.1.4.1.24062.2.2.1.4.6.2.1.2ColumnstpPerPortInfoRoleread-onlycurrentDescriptive information about RSTP switch port roles: root(1) A forwarding port that has been elected for the spanning-tree topology. alternate(2) An alternate…
1.3.6.1.4.1.24062.2.2.1.4.6.2.1.3ColumnstpPerPortInfoStateread-onlycurrent
1.3.6.1.4.1.24062.2.2.1.4.6.2.1.4ColumnstpPerPortInfoPathCostread-onlycurrentThe cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000.
1.3.6.1.4.1.24062.2.2.1.4.6.2.1.5ColumnstpPerPortInfoPriorityread-onlycurrentDecide which port should be blocked by priority in LAN. Enter a number 0 through 240 in steps of 16.
1.3.6.1.4.1.24062.2.2.1.4.6.2.1.6ColumnstpPerPortInfoLinkTyperead-onlycurrentSome of the rapid state transactions that are possible within RSTP are dependent upon whether the Port concerned can only be connected to exactly one other Bri…
1.3.6.1.4.1.24062.2.2.1.4.6.2.1.7ColumnstpPerPortInfoEdgePortread-onlycurrentPresent in implementations that support the identification of edge ports. All ports directly connected to end stations cannot create bridging loops in the netw…
1.3.6.1.4.1.24062.2.2.1.4.7Nodemstp
1.3.6.1.4.1.24062.2.2.1.4.7.1ScalarmstpRegionNameread-writecurrentMSTP region name.
1.3.6.1.4.1.24062.2.2.1.4.7.2ScalarmstpRegionRevisionread-writecurrentMSTP region revision.
1.3.6.1.4.1.24062.2.2.1.4.7.3TablemstpPerInstCfgTablenot-accessiblecurrentTable of descriptive information and configuration about STP on each port.
1.3.6.1.4.1.24062.2.2.1.4.7.3.1RowmstpPerInstCfgEntrynot-accessiblecurrentInformation configuring MSTP on a instance.
1.3.6.1.4.1.24062.2.2.1.4.7.3.1.1ColumnmstpPerInstCfgInstanceIDnot-accessiblecurrentThe instance ID.
1.3.6.1.4.1.24062.2.2.1.4.7.3.1.2ColumnmstpPerInstCfgVlanGroupread-writecurrentVLAN group of instance.
1.3.6.1.4.1.24062.2.2.1.4.7.3.1.3ColumnmstpPerInstCfgInstancePriorityread-writecurrentA value used to identify the instance root. The instance with the lowest value has the highest priority and is selected as the root. Enter a number 0 through 6…
1.3.6.1.4.1.24062.2.2.1.4.7.3.1.4ColumnmstpPerInstCfgStatusread-createcurrentStatus of this Instance.
1.3.6.1.4.1.24062.2.2.1.4.7.4TablemstpPerPortCfgTablenot-accessiblecurrentTable of descriptive information and configuration about MSTP on each port.
1.3.6.1.4.1.24062.2.2.1.4.7.4.1RowmstpPerPortCfgEntrynot-accessiblecurrentInformation configuring MSTP on a port.
1.3.6.1.4.1.24062.2.2.1.4.7.4.1.1ColumnmstpPerPortCfgIndexnot-accessiblecurrentThe index of MstpPerPortCfgEntry.
1.3.6.1.4.1.24062.2.2.1.4.7.4.1.2ColumnmstpPerPortCfgInstanceIDread-onlycurrentThe instance ID.
1.3.6.1.4.1.24062.2.2.1.4.7.4.1.3ColumnmstpPerPortCfgPortNumread-onlycurrentThe port number.
1.3.6.1.4.1.24062.2.2.1.4.7.4.1.4ColumnmstpPerPortCfgPathCostread-writecurrentThe cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number from 1 through 200000000. (0 will auto set path co…
1.3.6.1.4.1.24062.2.2.1.4.7.4.1.5ColumnmstpPerPortCfgPriorityread-writecurrentDecide which port should be blocked by priority in LAN. Enter a number from 0 through 240 in steps of 16.
1.3.6.1.4.1.24062.2.2.1.4.7.4.1.6ColumnmstpPerPortCfgLinkTyperead-writecurrentSome of the rapid state transactions that are possible within RSTP are dependent upon whether the Port concerned can only be connected to exactly one other Bri…
1.3.6.1.4.1.24062.2.2.1.4.7.4.1.7ColumnmstpPerPortCfgEdgePortread-writecurrentPresent in implementations that support the identification of edge ports. All ports directly connected to end stations cannot create bridging loops in the netw…
1.3.6.1.4.1.24062.2.2.1.4.8NodemstpBridgeInformation
1.3.6.1.4.1.24062.2.2.1.4.8.1TablemstpRootInformationTablenot-accessiblecurrentTable of descriptive information about root bridge of rapid spanning tree in this system.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1RowmstpRootInformationEntrynot-accessiblecurrentAn entry in the table, containing information about root bridge information of the MSTP.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.1ColumnmstpRootInformationInstanceIDread-onlycurrentThe instance ID.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.2ColumnmstpRootInformationRootAddressread-onlycurrentRoot Address.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.3ColumnmstpRootInformationRootPriorityread-onlycurrentRoot Priority.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.4ColumnmstpRootInformationRootPortread-onlycurrentRoot Port.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.5ColumnmstpRootInformationRootPathCostread-onlycurrentRoot Path Cost.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.6ColumnmstpRootInformationMaxAgeread-onlycurrentMax Age.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.7ColumnmstpRootInformationHelloTimeread-onlycurrentHello Time.
1.3.6.1.4.1.24062.2.2.1.4.8.1.1.8ColumnmstpRootInformationForwardDelayread-onlycurrentForward Delay Time.
1.3.6.1.4.1.24062.2.2.1.4.8.2TablemstpPerPortInfoTablenot-accessiblecurrentTable of descriptive information and configuration about rapid spanning tree (Per port).
1.3.6.1.4.1.24062.2.2.1.4.8.2.1RowmstpPerPortInfoEntrynot-accessiblecurrentAn entry in the table, containing information about MSTP (Per port).
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.1ColumnmstpPerPortInfoIndexnot-accessiblecurrentThe index of MstpPerPortInfoEntry.
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.2ColumnmstpPerPortInfoInstanceIDread-onlycurrentThe instance ID.
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.3ColumnmstpPerPortInfoPortNumread-onlycurrentPort number.
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.4ColumnmstpPerPortInfoRoleread-onlycurrentDescriptive information about MSTP switch port roles: disabled(1) MSTP is disabled on this port. root(2) A forwarding port that has been elected for the spanni…
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.5ColumnmstpPerPortInfoStateread-onlycurrent
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.6ColumnmstpPerPortInfoPathCostread-onlycurrentThe cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000.
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.7ColumnmstpPerPortInfoPriorityread-onlycurrentDecide which port should be blocked by priority in LAN. Enter a number 0 through 240 in steps of 16.
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.8ColumnmstpPerPortInfoLinkTyperead-onlycurrentSome of the rapid state transactions that are possible within MSTP are dependent upon whether the Port concerned can only be connected to exactly one other Bri…
1.3.6.1.4.1.24062.2.2.1.4.8.2.1.9ColumnmstpPerPortInfoEdgePortread-onlycurrentPresent in implementations that support the identification of edge ports. All ports directly connected to end stations cannot create bridging loops in the netw…
1.3.6.1.4.1.24062.2.2.1.5Nodevlan
1.3.6.1.4.1.24062.2.2.1.5.1ScalarvlanManagementVlanread-writecurrentThe VLAN from which managemnet traffic can access the device. By default, VLAN 1 is management VLAN.
1.3.6.1.4.1.24062.2.2.1.5.2Nodeieee8021qVlan
1.3.6.1.4.1.24062.2.2.1.5.2.1Tabledot1qPortVlanTablenot-accessiblecurrentA table containing per port control and status information for IEEE802.1Q VLAN configuration in the device.
1.3.6.1.4.1.24062.2.2.1.5.2.1.1Rowdot1qPortVlanEntrynot-accessiblecurrentInformation controlling IEEE802.1Q VLAN configuration for a port on the device.
1.3.6.1.4.1.24062.2.2.1.5.2.1.1.1Columndot1qPortIndexread-onlycurrentThe port identifier.
1.3.6.1.4.1.24062.2.2.1.5.2.1.1.2Columndot1qPvidread-writecurrentThe default Port VID, the VLAN ID assigned to an untagged frame or a Priority-Tagged frame received on the port.
1.3.6.1.4.1.24062.2.2.1.5.2.1.1.3Columndot1qPortAcceptableFrameTypesread-writecurrentWhen admitOnlyVlanTagged(2) the device will discard untagged frames or Priority-Tagged only frames received on this port. When admitAll(1), untagged frames or …
1.3.6.1.4.1.24062.2.2.1.5.2.1.1.4Columndot1qPortIngressFilteringread-writecurrentWhen true(1) the device will discard incoming frames whose VLAN classification do not include this port in its Member set. When false(2), the port will accept …
1.3.6.1.4.1.24062.2.2.1.5.2.2Tabledot1qVlanStaticTablenot-accessiblecurrentA table containing configuration information for each VLAN configured into the device by management. All entries are permanent and will be restored after the d…
1.3.6.1.4.1.24062.2.2.1.5.2.2.1Rowdot1qVlanStaticEntrynot-accessiblecurrentStatic information of a VLAN configured into the device by management.
1.3.6.1.4.1.24062.2.2.1.5.2.2.1.1Columndot1qVlanIndexread-onlycurrentThe VLAN Identifier (VID) refering to this VLAN. The valid range is from 1 to 4094.
1.3.6.1.4.1.24062.2.2.1.5.2.2.1.2Columndot1qVlanStaticNameread-writecurrentAn administratively assigned string, which is used to identify the VLAN.
1.3.6.1.4.1.24062.2.2.1.5.2.2.1.3Columndot1qVlanStaticEgressPortsread-onlycurrentThe set of ports which are permanently configured to transmitting traffic for this VLAN as either tagged or untagged frames. Each octet within this value speci…
1.3.6.1.4.1.24062.2.2.1.5.2.2.1.4Columndot1qVlanStaticUntaggedPortsread-createcurrentThe set of ports which are permanently configured to transmitting traffic for this VLAN as untagged frames. Each octet within this value specifies a set of eig…
1.3.6.1.4.1.24062.2.2.1.5.2.2.1.5Columndot1qVlanStaticTaggedPortsread-createcurrentThe set of ports which are permanently configured to transmitting traffic for this VLAN as tagged frames. Each octet within this value specifies a set of eight…
1.3.6.1.4.1.24062.2.2.1.5.2.2.1.6Columndot1qVlanStaticRowStatusread-createcurrentThis object is used to manage to creation and deletion of a VLAN, and is used to indicate the status of this entry. To Creating and activate a VLAN, first sele…
1.3.6.1.4.1.24062.2.2.1.5.2.3Nodedot1qGvrp
1.3.6.1.4.1.24062.2.2.1.5.2.3.1Scalardot1qGvrpStatusread-writecurrentEnable GVRP Protocol.
1.3.6.1.4.1.24062.2.2.1.5.2.3.2Tabledot1qPortGvrpTablenot-accessiblecurrentA table containing per port control and status information for GVRP configuration in the device.
1.3.6.1.4.1.24062.2.2.1.5.2.3.2.1Rowdot1qPortGvrpEntrynot-accessiblecurrentInformation controlling GVRP configuration for a port on the device.
1.3.6.1.4.1.24062.2.2.1.5.2.3.2.1.1Columndot1qPortGvrpIndexnot-accessiblecurrentThe port identifier.
1.3.6.1.4.1.24062.2.2.1.5.2.3.2.1.2Columndot1qPortGvrpStatusread-writecurrentThe state of GVRP operation on this port. The value enabled(1) indicates that GVRP is enabled on this port, as long as dot1qGvrpStatus is also enabled for this…
1.3.6.1.4.1.24062.2.2.1.5.2.3.2.1.3Columndot1qPortGarpJoinTimerread-writecurrentThe GARP Join timer, in centiseconds.
1.3.6.1.4.1.24062.2.2.1.5.2.3.2.1.4Columndot1qPortGarpLeaveTimerread-writecurrentThe GARP Leave time, in centiseconds.
1.3.6.1.4.1.24062.2.2.1.5.2.3.2.1.5Columndot1qPortGarpLeaveAllTimerread-writecurrentThe GARP LeaveAll time, in centiseconds.
1.3.6.1.4.1.24062.2.2.1.5.2.4Tabledot1qVlanCurrentTablenot-accessiblecurrentA table containing information about currently configured VLANs, either by (local or network) management, or dynamically created as a result of GVRP requests r…
1.3.6.1.4.1.24062.2.2.1.5.2.4.1Rowdot1qVlanCurrentEntrynot-accessiblecurrentInformation for a VLAN configured into the device by (local or network) management, or dynamically created as a result of GVRP requests received.
1.3.6.1.4.1.24062.2.2.1.5.2.4.1.1Columndot1qVlanCurrentIndexread-onlycurrentThe VLAN Identifier (VID) refering to this VLAN.
1.3.6.1.4.1.24062.2.2.1.5.2.4.1.2Columndot1qVlanCurrentEgressPortsread-onlycurrentThe set of ports which are transmitting traffic for this VLAN as either tagged or untagged frames.
1.3.6.1.4.1.24062.2.2.1.5.2.4.1.3Columndot1qVlanCurrentUntaggedPortsread-onlycurrentThe set of ports which are transmitting traffic for this VLAN as untagged frames.
1.3.6.1.4.1.24062.2.2.1.5.2.4.1.4Columndot1qVlanStatusread-onlycurrentThis object indicates the status of this entry. other(1) - this entry is currently in use but the conditions under which it will remain so differ from the foll…
1.3.6.1.4.1.24062.2.2.1.5.2.5Nodedot1qTunnel
1.3.6.1.4.1.24062.2.2.1.5.2.5.1Scalardot1qTunnelEtherTyperead-writecurrentethertype/TPID
1.3.6.1.4.1.24062.2.2.1.5.2.5.2Tabledot1qTunnelPortTablenot-accessiblecurrentA table containing per tunnel access or uplink port information in the device.
1.3.6.1.4.1.24062.2.2.1.5.2.5.2.1Rowdot1qTunnelPortEntrynot-accessiblecurrentInformation controlling tunnel configuration for a port on the device.
1.3.6.1.4.1.24062.2.2.1.5.2.5.2.1.1Columndot1qTunnelPortIndexnot-accessiblecurrentThe port identifier.
1.3.6.1.4.1.24062.2.2.1.5.2.5.2.1.2Columndot1qTunnelPortModeread-writecurrentTunnel mode controls
1.3.6.1.4.1.24062.2.2.1.5.3NodeprivateVlan
1.3.6.1.4.1.24062.2.2.1.5.3.1TableprivateVlanIdTablenot-accessiblecurrentA table containing per Private VLAN ID information in the device.
1.3.6.1.4.1.24062.2.2.1.5.3.1.1RowprivateVlanIdEntrynot-accessiblecurrentInformation controlling Private VLAN ID configuration on the device.
1.3.6.1.4.1.24062.2.2.1.5.3.1.1.1ColumnprivateVlanIdnot-accessiblecurrentThe Private VLAN ID.
1.3.6.1.4.1.24062.2.2.1.5.3.1.1.2ColumnprivateVlanIdTyperead-writecurrentPrivate VLAN ID type controls
1.3.6.1.4.1.24062.2.2.1.5.3.2TableprivateVlanPortTablenot-accessiblecurrentA table containing per Private VLAN Port information in the device.
1.3.6.1.4.1.24062.2.2.1.5.3.2.1RowprivateVlanPortEntrynot-accessiblecurrentInformation controlling Private VLAN Port configuration on the device.
1.3.6.1.4.1.24062.2.2.1.5.3.2.1.1ColumnprivateVlanPortIndexnot-accessiblecurrentThe Private Port Index.
1.3.6.1.4.1.24062.2.2.1.5.3.2.1.2ColumnprivateVlanPortModeread-writecurrentPrivate VLAN Port mode controls
1.3.6.1.4.1.24062.2.2.1.5.3.3TableprivateVlanHostAssociationTablenot-accessiblecurrentA table containing per Private VLAN host port association information in the device.
1.3.6.1.4.1.24062.2.2.1.5.3.3.1RowprivateVlanHostAssociationEntrynot-accessiblecurrentInformation controlling Private VLAN host port association configuration on the device.
1.3.6.1.4.1.24062.2.2.1.5.3.3.1.1ColumnprivateVlanHostAssociationPortIndexnot-accessiblecurrentThe Private Host Port Index.
1.3.6.1.4.1.24062.2.2.1.5.3.3.1.2ColumnprivateVlanHostAssociationPrimaryVidread-writecurrentPrivate VLAN host Port association primary VLAN ID. If enter 0 then clear setting.
1.3.6.1.4.1.24062.2.2.1.5.3.3.1.3ColumnprivateVlanHostAssociationSecondaryVidread-writecurrentPrivate VLAN host Port association secondary VLAN ID(isolated/community). If enter 0 then clear setting.
1.3.6.1.4.1.24062.2.2.1.5.3.4TableprivateVlanMappingTablenot-accessiblecurrentA table containing per Private VLAN promiscuous port mapping information in the device.
1.3.6.1.4.1.24062.2.2.1.5.3.4.1RowprivateVlanMappingEntrynot-accessiblecurrentInformation controlling Private VLAN promiscuous port mapping configuration on the device.
1.3.6.1.4.1.24062.2.2.1.5.3.4.1.1ColumnprivateVlanMappingPromiscuousPortIndexnot-accessiblecurrentThe Private Promiscuous Port Index.
1.3.6.1.4.1.24062.2.2.1.5.3.4.1.2ColumnprivateVlanMappingPrimaryVidread-writecurrentPrivate VLAN promiscuous Port mapping primary VLAN ID. If enter 0 then clear setting.
1.3.6.1.4.1.24062.2.2.1.5.3.4.1.3ColumnprivateVlanMappingSecondaryVidListread-writecurrentPrivate VLAN promiscuous Port mapping secondary VLAN ID list. If enter zero-length string then clear setting.
1.3.6.1.4.1.24062.2.2.1.6NodetrafficPrioritization
1.3.6.1.4.1.24062.2.2.1.6.1ScalarqosPolicyread-writecurrent(1)8,4,2,1 weight round robin scheme: the switch will follow 8:4:2:1 rate to process priority queue from Hi to lowest queue. This approach prevents the lower p…
1.3.6.1.4.1.24062.2.2.1.6.2TableqosPortDefaultCosTablenot-accessiblecurrentTable of descriptive information and configuration about port default cos value.
1.3.6.1.4.1.24062.2.2.1.6.2.1RowqosPortDefaultCosEntrynot-accessiblecurrentAn entry in the table, containing inforamtion about port default cos value.
1.3.6.1.4.1.24062.2.2.1.6.2.1.1ColumnqosPortNumread-onlycurrentPort number.
1.3.6.1.4.1.24062.2.2.1.6.2.1.2ColumnqosPortTrustread-writecurrentTwo kinds of priority information are token into consideration when a packet is processed. One is COS, the IEEE 802.3ac tag containing IEEE 802.1p priority inf…
1.3.6.1.4.1.24062.2.2.1.6.2.1.3ColumnqosPortDefaultCosread-writecurrentThe port priority will follow the default port priority
1.3.6.1.4.1.24062.2.2.1.6.3TableqosCOSTablenot-accessiblecurrentTable of descriptive information and configuration about COS QOS.
1.3.6.1.4.1.24062.2.2.1.6.3.1RowqosCOSEntrynot-accessiblecurrentAn entry in the table, containing inforamtion about COS QOS.
1.3.6.1.4.1.24062.2.2.1.6.3.1.1ColumnqosCOSPriorityread-onlycurrentCOS priority.
1.3.6.1.4.1.24062.2.2.1.6.3.1.2ColumnqosCOSread-writecurrentThe port priority will follow the COS priority that you have assigned (0)low, (1)middle, (2)high, or (3)highest.
1.3.6.1.4.1.24062.2.2.1.6.4TableqosDscpTablenot-accessiblecurrentTable of descriptive information and configuration about DSCP QOS.
1.3.6.1.4.1.24062.2.2.1.6.4.1RowqosDscpEntrynot-accessiblecurrentAn entry in the table, containing inforamtion about DSCP QOS.
1.3.6.1.4.1.24062.2.2.1.6.4.1.1ColumnqosDscpPriorityread-onlycurrentDscp priority.
1.3.6.1.4.1.24062.2.2.1.6.4.1.2ColumnqosDscpread-writecurrentThe port priority will follow the Dscp priority that you have assigned (0)low (1)middle, (2)high, (3)highest.
1.3.6.1.4.1.24062.2.2.1.7NodemulticastFiltering
1.3.6.1.4.1.24062.2.2.1.7.1NodeigmpQuery
1.3.6.1.4.1.24062.2.2.1.7.1.1ScalarigmpQueryVersionread-writecurrent(1)IGMP Query version 1. (2)IGMP Query version 2.
1.3.6.1.4.1.24062.2.2.1.7.1.2ScalarigmpQueryStatusread-writecurrent(1)enable IGMP Query on management vlan. (2)disable IGMP Query.
1.3.6.1.4.1.24062.2.2.1.7.1.3ScalarigmpQueryIntervalread-writecurrentThe interval between General Queries sent by this Querier in seconds.
1.3.6.1.4.1.24062.2.2.1.7.1.4ScalarigmpQueryMaxResponseTimeread-writecurrentMax Respocse Time is meaningful only in Membership Query messages, and specifies the maximum allowed time before sending a responding report in seconds.
1.3.6.1.4.1.24062.2.2.1.7.2NodeigmpSnooping
1.3.6.1.4.1.24062.2.2.1.7.2.1ScalarigmpSnoopingStatusread-writecurrentParameter to enable or disable IGMP snooping on the device. When enabled, the device will examine IGMP packets and set up filters for multicast traffic. The In…
1.3.6.1.4.1.24062.2.2.1.7.2.2TableigmpSnoopingTablenot-accessiblecurrentTable of descriptive information about on which vlan is IGMP snooping enabled.
1.3.6.1.4.1.24062.2.2.1.7.2.2.1RowigmpSnoopingEntrynot-accessiblecurrentInforamtion enabling or disabling IGMP snooping on a vlan.
1.3.6.1.4.1.24062.2.2.1.7.2.2.1.1ColumnigmpSnoopingEntryVIDread-onlycurrentThe vlan id.
1.3.6.1.4.1.24062.2.2.1.7.2.2.1.2ColumnigmpSnoopingEntryStatusread-writecurrentThe state of igmp snooping functionality on a vlan. Set to enabled(1) indicates that igmp snooping is enabled on the vlan. When igmpSnoopingStatus is also turn…
1.3.6.1.4.1.24062.2.2.1.7.2.3TableigmpSnoopingGroupTablenot-accessiblecurrentTable of descriptive information about IGMP snooped multicast groups.
1.3.6.1.4.1.24062.2.2.1.7.2.3.1RowigmpSnoopingGroupEntrynot-accessiblecurrentInformation containing a multicast group and its member ports.
1.3.6.1.4.1.24062.2.2.1.7.2.3.1.1ColumnigmpSnoopingGroupEntryVIDread-onlycurrentThe VLAN ID of an IGMP entry.
1.3.6.1.4.1.24062.2.2.1.7.2.3.1.2ColumnigmpSnoopingGroupEntryIPAddrread-onlycurrentThe multicast group IP address.
1.3.6.1.4.1.24062.2.2.1.7.2.3.1.3ColumnigmpSnoopingGroupEntryMembersread-onlycurrentThe member ports of the group.
1.3.6.1.4.1.24062.2.2.1.7.3NodeunknownMulticast
1.3.6.1.4.1.24062.2.2.1.7.3.1ScalarunknownMulticastStatusread-writecurrentSelect IGMP Unknown Multicast policy. (1) Send to Query Ports: The device sends the packets with an unknown MAC/IP Multicast address to query ports (2) Discard…
1.3.6.1.4.1.24062.2.2.1.8Nodesnmp
1.3.6.1.4.1.24062.2.2.1.8.1TablesnmpCommunityStringTablenot-accessiblecurrentTable of information configuring community strings of SNMP agent. An SNMP community string is a text string that acts as a password. It is used to authenticate…
1.3.6.1.4.1.24062.2.2.1.8.1.1RowsnmpCommunityStringEntrynot-accessiblecurrentInforamtion configuring an community string.
1.3.6.1.4.1.24062.2.2.1.8.1.1.1ColumnsnmpCommunityStringIndexnot-accessiblecurrentIndex of community string.
1.3.6.1.4.1.24062.2.2.1.8.1.1.2ColumnsnmpCommunityStringNameread-writecurrentA community string with maximum 32 characters.
1.3.6.1.4.1.24062.2.2.1.8.1.1.3ColumnsnmpCommunityStringPrivilegeread-writecurrentThe access privilege of the community string.
1.3.6.1.4.1.24062.2.2.1.8.1.1.4ColumnsnmpCommunityStringStatusread-createcurrentThe status of this entry. Set to (5)createAndWait to create a new entry. A new entry or an active entry can be edited. Once an entry is modified, its status be…
1.3.6.1.4.1.24062.2.2.1.8.2TablesnmpV3UserTablenot-accessiblecurrentTable of descriptive and information about trap servers. A trap server is the recipient of an SNMP trap. The device does not send a trap unless it knows to whi…
1.3.6.1.4.1.24062.2.2.1.8.2.1RowsnmpV3UserEntrynot-accessiblecurrentAn entry in the table, containing inforamtion about a trap server of SNMP agent.
1.3.6.1.4.1.24062.2.2.1.8.2.1.1ColumnsnmpV3UserIndexnot-accessiblecurrentIndex of snmp v3 user.
1.3.6.1.4.1.24062.2.2.1.8.2.1.2ColumnsnmpV3UserNameread-writecurrent
1.3.6.1.4.1.24062.2.2.1.8.2.1.3ColumnsnmpV3UserSecurityLevelread-writecurrentSpecifiy the authentication and privacy level - noauth(1) no authentication and no privacy. - auth(2) enables MD5 or SHA packet authentication. - priv(3) enabl…
1.3.6.1.4.1.24062.2.2.1.8.2.1.4ColumnsnmpV3UserAuthProtocolread-writecurrentMD5(Message Digest 5) or SHA (Secure Hash Algorithm)
1.3.6.1.4.1.24062.2.2.1.8.2.1.5ColumnsnmpV3UserAuthPasswordread-writecurrent
1.3.6.1.4.1.24062.2.2.1.8.2.1.6ColumnsnmpV3UserDesPasswordread-writecurrent
1.3.6.1.4.1.24062.2.2.1.8.2.1.7ColumnsnmpV3UserStatusread-createcurrent
1.3.6.1.4.1.24062.2.2.1.8.3ScalarsnmpTrapServerEnableread-writecurrentTo enable, disable snmp trap functionality. SNMPv1 traps are defined in RFC 1157, and SNMPv2c trap is defined as NOTIFICATION. SNMP traps enable this device to…
1.3.6.1.4.1.24062.2.2.1.8.4TablesnmpTrapServerTablenot-accessiblecurrentTable of descriptive and information about trap servers. A trap server is the recipient of an SNMP trap. The device does not send a trap unless it knows to whi…
1.3.6.1.4.1.24062.2.2.1.8.4.1RowsnmpTrapServerEntrynot-accessiblecurrentAn entry in the table, containing inforamtion about a trap server of SNMP agent.
1.3.6.1.4.1.24062.2.2.1.8.4.1.1ColumnsnmpTrapServerIndexnot-accessiblecurrentIndex of trap server.
1.3.6.1.4.1.24062.2.2.1.8.4.1.2ColumnsnmpTrapServerIPAddrread-writecurrentTrap Server IP Address.
1.3.6.1.4.1.24062.2.2.1.8.4.1.3ColumnsnmpTrapServerTrapCommread-writecurrentThe community string of trap server. The password-like string will be sent with the notification operation.
1.3.6.1.4.1.24062.2.2.1.8.4.1.4ColumnsnmpTrapServerTrapVerread-writecurrentThe trap version.
1.3.6.1.4.1.24062.2.2.1.8.4.1.5ColumnsnmpTrapServerStatusread-createcurrentThe status of this entry. Set to (5)createAndWait to create a new entry. A new entry or an active entry can be edited. Once an entry is modified, its status be…
1.3.6.1.4.1.24062.2.2.1.10Nodewarning
1.3.6.1.4.1.24062.2.2.1.10.1NodefaultRelay
1.3.6.1.4.1.24062.2.2.1.10.1.1TablefaultRelayTablenot-accessiblecurrentTable of configuration about fault relay. A fault relay is able to control an output circuit which is triggered by management defined fault events. There are t…
1.3.6.1.4.1.24062.2.2.1.10.1.1.1RowfaultRelayEntrynot-accessiblecurrentA entry controlling a fault relay configuration.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.1ColumnfaultRelayIdread-onlycurrentIndex of fault relay.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.2ColumndiConfigread-writecurrentThe fault relay will be triggered if digital input is low or high.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.3ColumndryOutputConfigread-writecurrentThe dry output mechanism of fault relay will be enabled or disable.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.4ColumndryOutputOnPeriodread-writecurrentThe fault relay will be closed after a period (in seconds). Together with dryOutputOffPeriod, the fault relay can be configured to continue on and off.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.5ColumndryOutputOffPeriodread-writecurrentThe fault relay will be opened after a period (in seconds). Together with dryOutputOnPeriod, the fault relay can be configured to continue on and off.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.6ColumnpowerFailureConfigread-writecurrentThe fault relay will be triggered if the configured power fails. Any means either power 1 or power2 fails
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.7ColumnlinkFailureConfigread-writecurrentThe fault relay will be trigger if any of the configured links fails.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.8ColumnpingConfigread-writecurrentThe ping failure mechanism of fault relay will be enabled or disable.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.9ColumnpingIPread-writecurrentThe fault relay will be trigger if fail to ping the assigned IP address.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.10ColumnpingResetConfigread-writecurrentThe ping reset mechanism of fault relay will be enabled or disable.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.11ColumnpingResetIPread-writecurrentThe fault relay will be trigger if fail to ping the assigned IP address.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.12ColumnpingResetTimeread-writecurrentReset the ping process after pingResetTime, and then wait pingHoldTime to ping again.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.13ColumnpingResetHoldTimeread-writecurrentReset the ping process after pingResetTime, and then wait pingHoldTime to ping again.
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.14ColumnringFailureConfigread-writecurrentThe fault relay will be triggered if the configured ring fails.
1.3.6.1.4.1.24062.2.2.1.10.2NodeeventAndEmailWarning
1.3.6.1.4.1.24062.2.2.1.10.2.1NodeeventSelection
1.3.6.1.4.1.24062.2.2.1.10.2.1.1TablesystemEventTablenot-accessiblecurrentTable of descriptive information and controls the reactions to system events. Three types of reactions will be triggered: (1)logging in the switch or send logs…
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1RowsystemEventEntryread-onlycurrentAn entry containing type of system events.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.1ColumneventSystemEventIndexnot-accessiblecurrentIndex of events.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.2ColumneventDeviceColdStartEventread-writecurrentSelect which warning machanism to take place when the device cold starts.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.3ColumneventDeviceWarmStartEventread-writecurrentSelect which warning machanism to take place when the device warm starts.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.4ColumneventAuthenticationFailureEventread-writecurrentSelect which warning machanism to take place when authentication failure.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.5ColumneventRingEventread-writecurrentSelect which warning machanism to take place when ring event occured.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.6ColumneventPower1FailureEventread-writecurrentSelect which warning machanism to take place when power1 failure.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.7ColumneventPower2FailureEventread-writecurrentSelect which warning machanism to take place when power2 failure.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.8ColumneventFaultRelay1Eventread-writecurrentSelect which warning machanism to take place when a fault relay 1 is triggered.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.9ColumneventFaultRelay2Eventread-writecurrentSelect which warning machanism to take place when a fault relay 2 is triggered.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.10ColumneventTimeSynchronizeEventread-writecurrentSelect which warning machanism to take place when time synchronizatonn failed.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.11ColumneventSFPEventread-writecurrentSelect which warning machanism to take place when SFP event occured.
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.12ColumneventDI1ChangeEventread-writecurrentSelect which warning machanism to take place when DI1 changed .
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.13ColumneventDI2ChangeEventread-writecurrentSelect which warning machanism to take place when DI2 changed .
1.3.6.1.4.1.24062.2.2.1.10.2.1.1.1.14ColumneventLoopDetectionEventread-writecurrentSelect which warning machanism to take place when loop detection event occured.
1.3.6.1.4.1.24062.2.2.1.10.2.1.2TableportEventTablenot-accessiblecurrentTable of descriptive information and controls the reactions to port link up, link down, or both link up and down. Three types of reactions will be triggered: (…
1.3.6.1.4.1.24062.2.2.1.10.2.1.2.1RowportEventEntrynot-accessiblecurrentAn entry controlling the type of port events.
1.3.6.1.4.1.24062.2.2.1.10.2.1.2.1.1ColumneventPortNumberread-onlycurrentPort number.
1.3.6.1.4.1.24062.2.2.1.10.2.1.2.1.2ColumneventPortEventread-writecurrentSelect the port event to react to.
1.3.6.1.4.1.24062.2.2.1.10.2.2NodesysLogConfiguration
1.3.6.1.4.1.24062.2.2.1.10.2.2.1ScalarsysLogLocalStatusread-writecurrentParameter to configure if the log should to be kept in the device or not.
1.3.6.1.4.1.24062.2.2.1.10.2.2.2ScalarsysLogRemoteStatusread-writecurrentParameter to configure the log should be sent to a syslog server specified in sysLogServerAddr or not. When disabled or sysLogServerAddr is 0, the device will …
1.3.6.1.4.1.24062.2.2.1.10.2.2.3ScalarsysLogServerAddrread-writecurrentThe IP address of syslog server.
1.3.6.1.4.1.24062.2.2.1.10.2.3NodesmtpConfiguration
1.3.6.1.4.1.24062.2.2.1.10.2.3.1ScalareventEmailAlertStatusread-writecurrentParameter to enable the email alert feature, When enabled, the switch will send an email to the address presented in emailAlertRcptTable.
1.3.6.1.4.1.24062.2.2.1.10.2.3.2ScalareventEmailAlertServerread-writecurrentThe IP address of SMTP server. It can't be modified when eventEmailAlertStatus is disabled.
1.3.6.1.4.1.24062.2.2.1.10.2.3.3ScalareventEmailAlertAccountread-writecurrentThe email account for SMTP server. It can't be modified when eventEmailAlertAuthentication is disabled.
1.3.6.1.4.1.24062.2.2.1.10.2.3.4ScalareventEmailAlertAuthenticationread-writecurrentSet to (1)enabled if it needs authentication to connect to the SMTP server. It can't be modified when eventEmailAlertStatus is disabled.
1.3.6.1.4.1.24062.2.2.1.10.2.3.5ScalareventEmailAlertUserread-writecurrentThe email account for SMTP server. It can't be modified when eventEmailAlertAuthentication is disabled.
1.3.6.1.4.1.24062.2.2.1.10.2.3.6ScalareventEmailAlertPasswordwrite-onlycurrentThe password of email account. It can't be modified when eventEmailAlertAuthentication is disabled.
1.3.6.1.4.1.24062.2.2.1.10.2.3.7TableemailAlertRcptTablenot-accessiblecurrentTable configuring recipient email addresses.
1.3.6.1.4.1.24062.2.2.1.10.2.3.7.1RowemailAlertRcptEntrynot-accessiblecurrentAn entry containing recipient email address.
1.3.6.1.4.1.24062.2.2.1.10.2.3.7.1.1ColumneventEmailAlertRcptIndexnot-accessiblecurrentIndex of recipient Email address.
1.3.6.1.4.1.24062.2.2.1.10.2.3.7.1.2ColumneventEmailAlertRcptEmailAddrread-writecurrentA recipient email address.
1.3.6.1.4.1.24062.2.2.1.11NodemonitorandDiag
1.3.6.1.4.1.24062.2.2.1.11.1NodemacAddressTable
1.3.6.1.4.1.24062.2.2.1.11.1.1TablemacAddrTablenot-accessiblecurrentA table containing information about unicast or multicast MAC addresses that currently learned, configured by management or IGMP snooping.
1.3.6.1.4.1.24062.2.2.1.11.1.1.1RowmacAddrEntrynot-accessiblecurrentAn entry containing inforamtion about a MAC address entry.
1.3.6.1.4.1.24062.2.2.1.11.1.1.1.1ColumnmacAddressAddrread-writecurrentMAC address of the entry.
1.3.6.1.4.1.24062.2.2.1.11.1.1.1.2ColumnmacAddressTyperead-writecurrentThe type of this entry. dynamicUnicast(1) - unicast address that learned from source address of ingress frames. staticUnicast(2) - unicast address that configu…
1.3.6.1.4.1.24062.2.2.1.11.1.1.1.3ColumnmacAddressPortListread-writecurrentThe port list, which must be valid when creating a new entry.
1.3.6.1.4.1.24062.2.2.1.11.1.1.1.4ColumnmacAddressVlanIdread-writecurrentThe VLAN where the mac address learned from or configured to.
1.3.6.1.4.1.24062.2.2.1.11.1.1.1.5ColumnmacAddressStatusread-createcurrentThis object is used to manage to creation and deletion of a static entry, and is used to indicate the status of an entry. To Creating a static entry, select a …
1.3.6.1.4.1.24062.2.2.1.11.1.2ScalarmacAddrTableClearread-writecurrentSet to clear for cleaning all the dynamic MAC entries in the MAC address table.
1.3.6.1.4.1.24062.2.2.1.11.1.3ScalarmacAddrTableAgingTimeread-writecurrentThis value determines the interval that an automatic learned MAC address entry remains valid in the forwarding database, since its last access as a source addr…
1.3.6.1.4.1.24062.2.2.1.11.2NodeportStatistic
1.3.6.1.4.1.24062.2.2.1.11.2.1TableswitchPortStatTablenot-accessiblecurrentTable of descriptive and statistics information about each switch ports.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1RowswitchPortStatEntrynot-accessiblecurrentAn entry in the table containing descriptive information and statistics of a port.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.1ColumnswPortStatIndexnot-accessiblecurrentIndex of port statistic table.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.2ColumnswPortStatTyperead-onlycurrentIndicates the port type.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.3ColumnswPortStatLinkread-onlycurrentIndicates the link state.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.4ColumnswPortStatStateread-onlycurrentIndicates the port state.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.5ColumnswPortStatRXGoodPktread-onlycurrentThe count of good frames received, which is the total number of recieved unicast, broadcast, multicast and pause frames.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.6ColumnswPortStatRXBadPktread-onlycurrentThe count of bad frames received, which is the total number of undersize, fragment, oversize, jabber, RXErr and FCSErr frames.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.7ColumnswPortStatRXAbortPktread-onlycurrentThe count of abort frames when receive, which is the total number of discarded and filtered frames.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.8ColumnswPortStatTXGoodPktread-onlycurrentThe count of good frames transmitted, which is the total number of transmitted unicast, broadcast, multicast and pause frames.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.9ColumnswPortStatTXBadPktread-onlycurrentThe count of FCSErr frames when transmit.
1.3.6.1.4.1.24062.2.2.1.11.2.1.1.10ColumnswPortStatPacketCollisionread-onlycurrentThe count of collision.
1.3.6.1.4.1.24062.2.2.1.11.2.2ScalarswitchPortStatClearwrite-onlycurrentSet to clear(1) to clear all information in the statistics table.
1.3.6.1.4.1.24062.2.2.1.11.3Nodeportmirroring
1.3.6.1.4.1.24062.2.2.1.11.3.1ScalarportMirrorStatusread-writecurrentTo enable or disable port mirroring. Port mirroring is used to send a copy of inbound or outbound network packets seen on one port to another switch port. Admi…
1.3.6.1.4.1.24062.2.2.1.11.3.2ScalarportMirrorDestinationPortTXread-writecurrentThe TX destination port (sniffer port). Destination port can be used to see all monitor port traffic. You can connect sniffer port to a LAN analysier or netxra…
1.3.6.1.4.1.24062.2.2.1.11.3.3ScalarportMirrorDestinationPortRXread-writecurrentThe RX destination port (sniffer port). Destination port can be used to see all monitor port traffic. You can connect sniffer port to a LAN analysier or netxra…
1.3.6.1.4.1.24062.2.2.1.11.3.4TableportMirrorSourceTablenot-accessiblecurrentTable of descriptive information and configuration of port mirroring in this system. Use this table to select monitor port for this switch.
1.3.6.1.4.1.24062.2.2.1.11.3.4.1RowportMirrorSourceEntrynot-accessiblecurrentInformation configuring port mirroring on each port.
1.3.6.1.4.1.24062.2.2.1.11.3.4.1.1ColumnportMirrorPortNumread-onlycurrentThe Port number.
1.3.6.1.4.1.24062.2.2.1.11.3.4.1.2ColumnportMirrorSourcePortread-writecurrentThe mode of source port (monitor port). (1) TX only. (2) RX only. (3) RX and TX. (4) Source port is disabled. The ports you want to monitor. All source port tr…
1.3.6.1.4.1.24062.2.2.1.11.4NodeeventLog
1.3.6.1.4.1.24062.2.2.1.11.4.1ScalareventLogClearread-writecurrentclear all event log.
1.3.6.1.4.1.24062.2.2.1.11.4.2TableeventLogTablenot-accessiblecurrentTable of descriptive information about logs.
1.3.6.1.4.1.24062.2.2.1.11.4.2.1RoweventLogEntrynot-accessiblecurrentAn entry in the table containing a log.
1.3.6.1.4.1.24062.2.2.1.11.4.2.1.1ColumneventLogIndexread-onlycurrentIndex of log.
1.3.6.1.4.1.24062.2.2.1.11.4.2.1.2ColumneventLogDescriptionread-onlycurrentThe description of a log.
1.3.6.1.4.1.24062.2.2.1.11.5NodetopologyDiscovery
1.3.6.1.4.1.24062.2.2.1.11.5.1ScalarlldpRunread-writecurrentLLDP Enable/Disable
1.3.6.1.4.1.24062.2.2.1.11.5.2ScalarlldpTimerread-writecurrentThe transmission frequency of LLDP in seconds
1.3.6.1.4.1.24062.2.2.1.11.5.3ScalarlldpHoldTimeread-writecurrentThe transmission frequency of LLDP in seconds
1.3.6.1.4.1.24062.2.2.1.11.5.4TablelldpNeighborTablenot-accessiblecurrentA table containing LLDP neighbors information
1.3.6.1.4.1.24062.2.2.1.11.5.4.1RowlldpNeighborEntrynot-accessiblecurrentAn entry containing inforamtion about a LLDP neighbor entry.
1.3.6.1.4.1.24062.2.2.1.11.5.4.1.1ColumnlldpNeighborLocalPortread-onlycurrentLocal port of LLDP Neighbor
1.3.6.1.4.1.24062.2.2.1.11.5.4.1.2ColumnlldpNeighborMacAddressread-onlycurrentMAC address of LLDP Neighbor
1.3.6.1.4.1.24062.2.2.1.11.5.4.1.3ColumnlldpNeighborIpAddressread-onlycurrentIP address of LLDP Neighbor
1.3.6.1.4.1.24062.2.2.1.11.5.4.1.4ColumnlldpNeighborVIDread-onlycurrentVLAN ID of LLDP Neighbor
1.3.6.1.4.1.24062.2.2.1.11.5.4.1.5ColumnlldpNeighborTTLread-onlycurrentTTL of LLDP Neighbor
1.3.6.1.4.1.24062.2.2.1.11.6NodehardwareStatus
1.3.6.1.4.1.24062.2.2.1.11.6.1TablehardwareStatusTablenot-accessiblecurrent
1.3.6.1.4.1.24062.2.2.1.11.6.1.1RowhardwareStatusEntryread-onlycurrent
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.1ColumnledHardwareStatusIndexnot-accessiblecurrentIndex of leds.
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.2ColumnledPower1Statusread-onlycurrentThe status of Power 1 LED
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.3ColumnledPower2Statusread-onlycurrentThe status of Power 2 LED
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.4ColumnledDI1Statusread-onlycurrentThe status of DI 1 LED
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.5ColumnledDI2Statusread-onlycurrentThe status of DI 2 LED
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.6ColumnledDO1Statusread-onlycurrentThe status of DO 1 LED
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.7ColumnledDO2Statusread-onlycurrentThe status of DO 2 LED
1.3.6.1.4.1.24062.2.2.1.11.6.1.1.8ColumnledRMStatusread-onlycurrentThe status of RM LED
1.3.6.1.4.1.24062.2.2.1.12Nodesave
1.3.6.1.4.1.24062.2.2.1.12.1ScalarsaveCfgMgtActionread-writecurrentSetting this object to active(1) saves current configuration. Setting this object to notActive(2) has no effect. The system always returns the value notActive(…
1.3.6.1.5Nodesecurity
1.3.6.1.5.1NodeportSecurity
1.3.6.1.5.1.1TableportSecurityStatusTablenot-accessiblecurrentA table containing information about port security status on each port. Port security prevents a port from address learning. Only those MAC addresses that are …
1.3.6.1.5.1.1.1RowportSecurityStatusEntrynot-accessiblecurrentAn entry configuring port security for a port.
1.3.6.1.5.1.1.1.1ColumnportSecurityPortIndexnot-accessiblecurrentThe port id.
1.3.6.1.5.1.1.1.2ColumnportSecurityPortStatusread-writecurrent(1)enable port security on this port. (2)disable port security on this port.
1.3.6.1.5.1.2TableportSecurityMacTablenot-accessiblecurrentTable configuring static unicast MAC address for each port. When you add a static MAC address, it remains in the switch's address table, regardless of whether …
1.3.6.1.5.1.2.1RowportSecurityMacEntrynot-accessiblecurrentAn entry configuring a static unicast MAC addresses on a port.
1.3.6.1.5.1.2.1.1ColumnportSecurityMacIndexnot-accessiblecurrentIndex of MAC.
1.3.6.1.5.1.2.1.2ColumnportSecurityPortread-writecurrentThe port id.
1.3.6.1.5.1.2.1.3ColumnportSecurityVlanIndexread-writecurrentThe vlan id where the MAC address belongs to.
1.3.6.1.5.1.2.1.4ColumnportSecurityMacread-writecurrentMAC address of the entry.
1.3.6.1.5.1.2.1.5ColumnportSecurityMacStatusread-createcurrentThe status of this entry. Set to (5)createAndWait to create a new entry. A new entry or an active entry can be edited. Once an entry is modified, its status be…
1.3.6.1.5.2NodeipSecurity
1.3.6.1.5.2.1ScalaripSecurityStatusread-writecurrentEnable or disable IP security functionality. IP security allows you to assign specific IP addresses that are permitted to access the device for securing switch…
1.3.6.1.5.2.2TableipSecurityTablenot-accessiblecurrentTable configuring IP addresses that can access and manage the device through network, such as telnet, web or SNMP. Please note that enabling IP security functi…
1.3.6.1.5.2.2.1RowipSecurityEntrynot-accessiblecurrentAn entry configuring an security IP address.
1.3.6.1.5.2.2.1.1ColumnipSecurityIndexnot-accessiblecurrentIndex of IP address entry.
1.3.6.1.5.2.2.1.2ColumnipSecurityIPread-writecurrentAn IP address that can access and manage the device.
1.3.6.1.5.2.2.1.3ColumnipSecurityRowStatusread-createcurrentThis object is used to manage to creation and deletion of a authorized IP address, and is used to indicate the status of this entry. A empty entry or an active…
1.3.6.1.5.3Nodedot1x
1.3.6.1.5.3.1Scalardot1xStatusread-writecurrentIEEE802.1x protocol function status. (1) IEEE802.1x protocol function is enabled. (2) IEEE802.1x protocol function is disabled. 802.1x makes use of the physica…
1.3.6.1.5.3.2Scalardot1xAuthenticationread-writecurrent.
1.3.6.1.5.3.3TableradiusServerTablenot-accessiblecurrent.
1.3.6.1.5.3.3.1RowradiusServerEntrynot-accessiblecurrent.
1.3.6.1.5.3.3.1.1ColumnradiusServerIndexnot-accessiblecurrentIndex of Radius server configuration.
1.3.6.1.5.3.3.1.2ColumnradiusServerIpread-writecurrentIP address of this radius server.
1.3.6.1.5.3.3.1.3ColumnradiusServerServerPortread-writecurrentThe UDP port number used by the authentication server to authenticate.
1.3.6.1.5.3.3.1.4ColumnradiusServerAccountingPortread-writecurrentAccounting Port: The UDP port number used by the authentication server to retrieve accounting information.
1.3.6.1.5.3.3.1.5ColumnradiusServerSharedKeyread-writecurrentA key shared between this switch and authentication server.
1.3.6.1.5.3.4Tabledot1xLocalUserTablenot-accessiblecurrent.
1.3.6.1.5.3.4.1Rowdot1xLocalUserEntrynot-accessiblecurrent.
1.3.6.1.5.3.4.1.1Columndot1xLocalUserIndexnot-accessiblecurrent.
1.3.6.1.5.3.4.1.2Columndot1xLocalUserNameread-writecurrentset this field to empty to remove this user config.
1.3.6.1.5.3.4.1.3Columndot1xLocalUserPasswordread-writecurrent.
1.3.6.1.5.3.4.1.4Columndot1xLocalUserVidread-writecurrent.
1.3.6.1.5.3.5Tabledot1xPortConfigTablenot-accessiblecurrent.
1.3.6.1.5.3.5.1Rowdot1xPortConfigEntrynot-accessiblecurrent.
1.3.6.1.5.3.5.1.1Columndot1xPortConfigIndexnot-accessiblecurrent.
1.3.6.1.5.3.5.1.2Columndot1xPortAuthControlread-writecurrent.
1.3.6.1.5.3.5.1.3Columndot1xPortReauthenticationread-writecurrent.
1.3.6.1.5.3.5.1.4Columndot1xPortMaxRequestread-writecurrent.
1.3.6.1.5.3.5.1.5Columndot1xPortGuestVlanread-writecurrent.
1.3.6.1.5.3.5.1.6Columndot1xPortHostModeread-writecurrent.
1.3.6.1.5.3.5.1.7Columndot1xPortAdminDirectionread-writecurrent.
1.3.6.1.5.3.5.1.8Columndot1xPortConfigSetDefaultread-writecurrent.
1.3.6.1.5.3.5.1.9Columndot1xPortReinitializeread-writecurrent.
1.3.6.1.5.3.5.1.10Columndot1xPortClientReauthwrite-onlycurrent.
1.3.6.1.5.3.6Tabledot1xPortTimeoutConfigTablenot-accessiblecurrent.
1.3.6.1.5.3.6.1Rowdot1xPortTimeoutConfigEntrynot-accessiblecurrent.
1.3.6.1.5.3.6.1.1Columndot1xPortTimeoutIndexnot-accessiblecurrent.
1.3.6.1.5.3.6.1.2Columndot1xPortReauthPeriodread-writecurrent.
1.3.6.1.5.3.6.1.3Columndot1xPortQuietPeriodread-writecurrent.
1.3.6.1.5.3.6.1.4Columndot1xPortTxPeriodread-writecurrent.
1.3.6.1.5.3.6.1.5Columndot1xPortSupplicantTimeoutread-writecurrent.
1.3.6.1.5.3.6.1.6Columndot1xPortServerTimeoutread-writecurrent.
1.3.6.1.5.3.7Tabledot1xPortStatusTablenot-accessiblecurrent.
1.3.6.1.5.3.7.1Rowdot1xPortStatusEntrynot-accessiblecurrent.
1.3.6.1.5.3.7.1.1Columndot1xPortStatusIndexnot-accessiblecurrent.
1.3.6.1.5.3.7.1.2Columndot1xPortCtrlread-onlycurrent.
1.3.6.1.5.3.7.1.3Columndot1xPortAuthStatusread-onlycurrent.
1.3.6.1.5.3.7.1.4Columndot1xPortAuthSupplicantread-onlycurrent.
1.3.6.1.5.3.7.1.5Columndot1xPortOperDirectionread-onlycurrent.
Type Definitions
NameSyntaxStatusDescription
AlertTypeINTEGER { enable(1), disable(2) }current