LEXMARK-SETTINGS-DEFINITION
96 objects
The MIB defines the device settings definition permitting retrieval of the complete definition of the setting to permit usage/presentation by a remote tool. Copyright (C) 2014 Lexmark International, Inc.
Imported Objects
| LEXMARK-ROOT-MIB | lexmarkModules |
| LEXMARK-SETTINGS-MIB | settingsDefinition settingsMIBCompliances settingsMIBGroups |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.641.4.3 | IdentitysettingsDefinitionMibModule | The MIB defines the device settings definition permitting retrieval of the complete definition of the setting to permit usage/presentation by a remote tool. Co… | ||
| 1.3.6.1.4.1.641.7.1.1.2 | CompliancedefinitionMIBCompliance | current | The requirements for conformance to the LEXMARK-SETTINGS-CONTROL MIB. | |
| 1.3.6.1.4.1.641.7.1.2.3 | GroupdefinitionGroup | current | The Definition Group. | |
| 1.3.6.1.4.1.641.7.3.1 | TablenpaIdTable | not-accessible | current | A table of settings NPA IDs that have been returned. |
| 1.3.6.1.4.1.641.7.3.1.1 | RownpaIdEntry | not-accessible | current | An entry of the npaIdTable. |
| 1.3.6.1.4.1.641.7.3.1.1.1 | ColumnnpaIdIndex | read-only | current | A unique value used to identify this settingsDefinition entry index. |
| 1.3.6.1.4.1.641.7.3.2 | TablesettingTable | not-accessible | current | A table defining the setting attributes that are dependent only on the selected NPA ID index value. This information will permit usage and presentation of thes… |
| 1.3.6.1.4.1.641.7.3.2.1 | RowsettingEntry | not-accessible | current | An entry containing a setting attribute definition. |
| 1.3.6.1.4.1.641.7.3.2.1.1 | ColumnsettingName | read-only | current | Setting 'public name' definition. This is for tool usage and comparison of the setting definition to previous access methods. |
| 1.3.6.1.4.1.641.7.3.2.1.2 | ColumnsettingVccId | read-only | current | VCC setting Name if it exists. |
| 1.3.6.1.4.1.641.7.3.2.1.3 | ColumnsettingGroup | read-only | current | The Settings Group Identifier allows the remote tool to logically group settings into categories if desired. |
| 1.3.6.1.4.1.641.7.3.2.1.4 | ColumnsettingAccess | read-only | current | Indicates the access level (RO, RW, or W) |
| 1.3.6.1.4.1.641.7.3.2.1.5 | ColumnsettingReboot | read-only | current | Integer that indicates whether a reboot is required for activation or whether a change triggers a reboot |
| 1.3.6.1.4.1.641.7.3.2.1.6 | ColumnsettingDescription | read-only | current | Setting description string |
| 1.3.6.1.4.1.641.7.3.2.1.7 | ColumnsettingNpaId | read-only | current | NPA ID value that is used for the index in an accessible field. |
| 1.3.6.1.4.1.641.7.3.2.1.8 | ColumnsettingIdValue | read-only | current | ID for the Setting Name, permitting identification of the display string assigned to this setting.. For future use. |
| 1.3.6.1.4.1.641.7.3.2.1.9 | ColumnsettingIdStringName | read-only | current | The text string associated with the settingIdValue. For future use. |
| 1.3.6.1.4.1.641.7.3.2.1.10 | ColumnsettingIdLocalizedString | read-only | current | The localized text string associated with the settingIdValue, using the language selection specified in the LEXMARK-SETTINGS-CONTROL MIB. For future use. |
| 1.3.6.1.4.1.641.7.3.2.1.11 | ColumnsettingType | read-only | current | Specifies the type of this setting and must be looked at as a bit field. The first 3 bits are used to determine whether the Integer, String or Octet setting en… |
| 1.3.6.1.4.1.641.7.3.3 | TablesettingValueTable | not-accessible | current | A table defining the current and default values for the setting. The settingValueIndex is only used for settings that are indexed, storing multiple values asso… |
| 1.3.6.1.4.1.641.7.3.3.1 | RowsettingValueEntry | not-accessible | current | An entry containing a setting attribute definition. |
| 1.3.6.1.4.1.641.7.3.3.1.1 | ColumnsettingValueIndex | not-accessible | current | A unique value used to indicate the row of this table. |
| 1.3.6.1.4.1.641.7.3.3.1.2 | ColumnsettingNpaIndex | read-only | current | For settings which have a single value associated with them (non-indexed) this will have a value of 0. For settings which have more than one value associated w… |
| 1.3.6.1.4.1.641.7.3.3.1.3 | ColumnsettingCurrentValueIfInteger | read-write | current | Current value for the setting if the setting returns an integer result. Otherwise, this column will not be returned . |
| 1.3.6.1.4.1.641.7.3.3.1.4 | ColumnsettingCurrentValueIfString | read-write | current | Current value for the setting if the setting returns a string result. Otherwise, this column will not be returned . |
| 1.3.6.1.4.1.641.7.3.3.1.5 | ColumnsettingCurrentValueIfOctet | read-write | current | Current value for the setting if the setting returns an octet result. Otherwise, this column will not be returned . |
| 1.3.6.1.4.1.641.7.3.3.1.6 | ColumnsettingFactoryDefaultIfInteger | read-only | current | Factory Default Value for the setting if the setting returns an integer result. Otherwise, this column will not be returned. |
| 1.3.6.1.4.1.641.7.3.3.1.7 | ColumnsettingFactoryDefaultIfString | read-only | current | Factory Default Value for the setting if the setting returns a string result. Otherwise, this column will not be returned. |
| 1.3.6.1.4.1.641.7.3.3.1.8 | ColumnsettingFactoryDefaultIfOctet | read-only | current | Factory Default Value for the setting if the setting returns an octet result. Otherwise, this column will not be returned. |
| 1.3.6.1.4.1.641.7.3.4 | TablevalueRangeTable | not-accessible | current | A table of value ranges for a setting which returns an integer result. NOTE: If the 'signed' bit of settingType (in the settingTable) is 1 for the given settin… |
| 1.3.6.1.4.1.641.7.3.4.1 | RowvalueRangeEntry | not-accessible | current | An entry of the valueRangeTable. |
| 1.3.6.1.4.1.641.7.3.4.1.1 | ColumnvalueRangeMin | read-only | current | Minimum value. |
| 1.3.6.1.4.1.641.7.3.4.1.2 | ColumnvalueRangeMax | read-only | current | Max value. |
| 1.3.6.1.4.1.641.7.3.4.1.3 | ColumnvalueRangeIncrement | read-only | current | How much a value increments. |
| 1.3.6.1.4.1.641.7.3.4.1.4 | ColumnvalueRangeDecimalPlaces | read-only | current | How many decimal places do I have? |
| 1.3.6.1.4.1.641.7.3.5 | TableenumValuesTable | not-accessible | current | A table of enumeration values. |
| 1.3.6.1.4.1.641.7.3.5.1 | RowenumValuesEntry | not-accessible | current | An entry of the EnumValuesTable. |
| 1.3.6.1.4.1.641.7.3.5.1.1 | ColumnenumValuesIndex | not-accessible | current | A unique value used to identify this enumValuesEntry index. |
| 1.3.6.1.4.1.641.7.3.5.1.2 | ColumnenumValuesValueIfInt | read-only | current | Integer enum value. This column is not returned if the setting is a string enumeration. |
| 1.3.6.1.4.1.641.7.3.5.1.3 | ColumnenumValuesName | read-only | current | String setting value name that is derived from the VCC value name. |
| 1.3.6.1.4.1.641.7.3.5.1.4 | ColumnenumValuesTextIdValue | read-only | current | raw integer giving Text-ID value for the enum. For potential future usage. Note: if value is 0, then use enumTextIdLocalized string. |
| 1.3.6.1.4.1.641.7.3.5.1.5 | ColumnenumValuesTextIdString | read-only | current | Text-ID identifier string for the enum. For potential future usage. Note: if value is null, then use enumTextIdLocalized string. |
| 1.3.6.1.4.1.641.7.3.5.1.6 | ColumnenumValuesTextIdLocalized | read-only | current | Localized Text-ID string for the enum. For potential future usage |
| 1.3.6.1.4.1.641.7.3.5.1.7 | ColumnenumValuesValueIfString | read-only | current | String enumeration value. This column is not returned if the setting is an integer enumeration. |
| 1.3.6.1.4.1.641.7.3.6 | TablelimitsTable | not-accessible | current | A table of limits that is utilized when the setting value returned is a string or octet. |
| 1.3.6.1.4.1.641.7.3.6.1 | RowlimitsEntry | not-accessible | current | An entry of the limitsTable. |
| 1.3.6.1.4.1.641.7.3.6.1.1 | ColumnlimitsMaxLength | read-only | current | The maximum length of a string or octet in bytes. |
| 1.3.6.1.4.1.641.7.3.6.1.2 | ColumnlimitsMinLength | read-only | current | The minimum length of a string or octet in bytes. |
| 1.3.6.1.4.1.641.7.3.6.1.3 | ColumnregularExpression | read-only | current | The specific textual syntax that this setting needs to conform to. |
| 1.3.6.1.4.1.641.7.3.7 | NodesettingsQuery | |||
| 1.3.6.1.4.1.641.7.3.7.1 | ScalarqueryId | read-write | current | An NPA ID from the npaIdTable. Tables in the settingsQuery branch will only be populated with the information specified by this NPA ID. |
| 1.3.6.1.4.1.641.7.3.7.2 | TablequerySettingTable | not-accessible | current | A table defining the setting attributes that are dependent only on the selected NPA ID index value. This information will permit usage and presentation of thes… |
| 1.3.6.1.4.1.641.7.3.7.2.1 | RowquerySettingEntry | not-accessible | current | An entry containing a setting attribute definition. |
| 1.3.6.1.4.1.641.7.3.7.2.1.1 | ColumnquerySettingName | read-only | current | Setting 'public name' definition. This is for tool usage and comparison of the setting definition to previous access methods. |
| 1.3.6.1.4.1.641.7.3.7.2.1.2 | ColumnquerySettingVccId | read-only | current | VCC setting Name if it exists. |
| 1.3.6.1.4.1.641.7.3.7.2.1.3 | ColumnquerySettingGroup | read-only | current | The Settings Group Identifier allows the remote tool to logically group settings into categories if desired. |
| 1.3.6.1.4.1.641.7.3.7.2.1.4 | ColumnquerySettingAccess | read-only | current | Indicates the access level (RO, RW, or W) |
| 1.3.6.1.4.1.641.7.3.7.2.1.5 | ColumnquerySettingReboot | read-only | current | Integer that indicates whether a reboot is required for activation or whether a change triggers a reboot |
| 1.3.6.1.4.1.641.7.3.7.2.1.6 | ColumnquerySettingDescription | read-only | current | Setting description string |
| 1.3.6.1.4.1.641.7.3.7.2.1.7 | ColumnquerySettingNpaId | read-only | current | NPA ID value that is used for the index in an accessible field. |
| 1.3.6.1.4.1.641.7.3.7.2.1.8 | ColumnquerySettingIdValue | read-only | current | ID for the Setting Name, permitting identification of the display string assigned to this setting.. For future use. |
| 1.3.6.1.4.1.641.7.3.7.2.1.9 | ColumnquerySettingIdStringName | read-only | current | The text string associated with the settingIdValue. For future use. |
| 1.3.6.1.4.1.641.7.3.7.2.1.10 | ColumnquerySettingIdLocalizedString | read-only | current | The localized text string associated with the querySettingIdValue, using the language selection specified in the LEXMARK-SETTINGS-CONTROL MIB. For future use. |
| 1.3.6.1.4.1.641.7.3.7.2.1.11 | ColumnquerySettingType | read-only | current | Specifies the type of this setting and must be looked at as a bit field. The first 3 bits are used to determine whether the Integer, String or Octet setting en… |
| 1.3.6.1.4.1.641.7.3.7.3 | TablequerySettingValueTable | not-accessible | current | A table defining the current and default values for the setting. The querySettingIndex is only used for settings that are indexed, storing multiple values asso… |
| 1.3.6.1.4.1.641.7.3.7.3.1 | RowquerySettingValueEntry | not-accessible | current | An entry containing a setting attribute definition. |
| 1.3.6.1.4.1.641.7.3.7.3.1.1 | ColumnquerySettingValueIndex | not-accessible | current | A unique value used to identify this querySettingEntry index. |
| 1.3.6.1.4.1.641.7.3.7.3.1.2 | ColumnquerySettingNpaIndex | read-only | current | For settings which have a single value associated with them (non-indexed) this will have a value of 0. For settings which have more than one value associated w… |
| 1.3.6.1.4.1.641.7.3.7.3.1.3 | ColumnquerySettingCurValIfInt | read-only | current | Current value for the setting if the setting returns an integer result. Otherwise, this column will not be returned . |
| 1.3.6.1.4.1.641.7.3.7.3.1.4 | ColumnquerySettingCurrentValueIfString | read-only | current | Current value for the setting if the setting returns a string result. Otherwise, this column will not be returned . |
| 1.3.6.1.4.1.641.7.3.7.3.1.5 | ColumnquerySettingCurValIfOctet | read-only | current | Current value for the setting if the setting returns an octet result. Otherwise, this column will not be returned. |
| 1.3.6.1.4.1.641.7.3.7.3.1.6 | ColumnquerySettingFactDefIfInt | read-only | current | Factory Default Value for the setting if the setting returns an integer result. Otherwise, this column will not be returned. |
| 1.3.6.1.4.1.641.7.3.7.3.1.7 | ColumnquerySettingFactDefIfString | read-only | current | Factory Default Value for the setting if the setting returns a string result. Otherwise, this column will not be returned. |
| 1.3.6.1.4.1.641.7.3.7.3.1.8 | ColumnquerySettingFactDefIfOctet | read-only | current | Factory Default Value for the setting if the setting returns an octet result. Otherwise, this column will not be returned. |
| 1.3.6.1.4.1.641.7.3.7.4 | TablequeryValueRangeTable | not-accessible | current | A table of value ranges for a setting which returns an integer result. NOTE: If the 'signed' bit of settingType (in the settingTable) is 1 for the given settin… |
| 1.3.6.1.4.1.641.7.3.7.4.1 | RowqueryValueRangeEntry | not-accessible | current | An entry of the queryValueRangeTable. |
| 1.3.6.1.4.1.641.7.3.7.4.1.1 | ColumnqueryValueRangeMin | read-only | current | Minimum value. |
| 1.3.6.1.4.1.641.7.3.7.4.1.2 | ColumnqueryValueRangeMax | read-only | current | Max value. |
| 1.3.6.1.4.1.641.7.3.7.4.1.3 | ColumnqueryValueRangeIncrement | read-only | current | How much a value increments. |
| 1.3.6.1.4.1.641.7.3.7.4.1.4 | ColumnqueryValueRangeDecimalPlaces | read-only | current | How many decimal places do I have? |
| 1.3.6.1.4.1.641.7.3.7.5 | TablequeryEnumValuesTable | not-accessible | current | A table of enumeration values. |
| 1.3.6.1.4.1.641.7.3.7.5.1 | RowqueryEnumValuesEntry | not-accessible | current | An entry of the EnumValuesTable. |
| 1.3.6.1.4.1.641.7.3.7.5.1.1 | ColumnqueryEnumValuesIndex | not-accessible | current | A unique value used to identify this queryEnumValuesEntry index. |
| 1.3.6.1.4.1.641.7.3.7.5.1.2 | ColumnqueryEnumValuesValueIfInt | read-only | current | Integer enum value. This column is not returned if the setting is a string enumeration |
| 1.3.6.1.4.1.641.7.3.7.5.1.3 | ColumnqueryEnumValuesName | read-only | current | String setting value name that is derived from the VCC value name. |
| 1.3.6.1.4.1.641.7.3.7.5.1.4 | ColumnqueryEnumValuesTextIdValue | read-only | current | raw integer giving Text-ID value for the enum. For potential future usage. Note: if value is 0, then use enumTextIdLocalized string. |
| 1.3.6.1.4.1.641.7.3.7.5.1.5 | ColumnqueryEnumValuesTextIdString | read-only | current | Text-ID identifier string for the enum. For potential future usage. Note: if value is null, then use enumTextIdLocalized string. |
| 1.3.6.1.4.1.641.7.3.7.5.1.6 | ColumnqueryEnumValuesTextIdLocalized | read-only | current | Localized Text-ID string for the enum. For potential future usage |
| 1.3.6.1.4.1.641.7.3.7.5.1.7 | ColumnqueryEnumValuesValueIfString | read-only | current | String enumeration value. This column is not returned if the setting is an integer enumeration |
| 1.3.6.1.4.1.641.7.3.7.6 | TablequeryLimitsTable | not-accessible | current | A table of limits that is utilized when the setting value returned is a String or Octet. |
| 1.3.6.1.4.1.641.7.3.7.6.1 | RowqueryLimitsEntry | not-accessible | current | An entry of the limitsTable. |
| 1.3.6.1.4.1.641.7.3.7.6.1.1 | ColumnqueryLimitsMaxLength | read-only | current | The maximum length of a string or octet in bytes. |
| 1.3.6.1.4.1.641.7.3.7.6.1.2 | ColumnqueryLimitsMinLength | read-only | current | The minimum length of a string or octet in bytes. |
| 1.3.6.1.4.1.641.7.3.7.6.1.3 | ColumnqueryRegularExpression | read-only | current | The specific textual syntax that this setting needs to conform to. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| SettingsGroupTC | INTEGER{ ftp(1), copy(2), email(3), network(4), usb(5), color(6), device(7), ports(8), auth(9), audit(10), scan(11), scanHw(12), paper(13), scanQuality(14), output(15), input(16), alerts(17), engine(18), cartridge(19), fax(20), faxMedia(21), faxQuality(22), printHw(23), lexconnect(24), securityGen(25), usage(26), esf(27), pageLayout(28), photo(29), print(30), printMedia(31), supplies(32), ui(33), secureNet(34), servers(35), adapters(36), interfaces(37), pcl(38), debug(39), ps(40), ppds(41), finisher(42), ocr(43), accessibility(44), csf(45), logging(46), internal(47), undefined(50) } | current | Group settings category. |
| SettingsReservedTC | INTEGER { reserved(0), reserved2(1) } | current | Reserved |