LMS-MIB
114 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1213 MISSING | DisplayString |
| RFC1155-SMI | enterprises |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.885 | NodeemersonESNA | |||
| 1.3.6.1.4.1.885.2 | Nodelms | |||
| 1.3.6.1.4.1.885.2.1 | NodelmsSystem | |||
| 1.3.6.1.4.1.885.2.2 | NodelmsCounts | |||
| 1.3.6.1.4.1.885.2.2.1 | ScalarbinaryChannelNumber | read-only | mandatory | The number of Binary channels in the system. |
| 1.3.6.1.4.1.885.2.2.2 | ScalaranalogChannelNumber | read-only | mandatory | The number of Analog channels in the system. |
| 1.3.6.1.4.1.885.2.2.3 | ScalarrelayChannelNumber | read-only | mandatory | The number of Relay channels in the system. |
| 1.3.6.1.4.1.885.2.2.4 | ScalarledChannelNumber | read-only | mandatory | The number of LED channels in the system. |
| 1.3.6.1.4.1.885.2.2.5 | ScalarenergyChannelNumber | read-only | mandatory | The number of Energy Management channels in the system. |
| 1.3.6.1.4.1.885.2.2.6 | ScalarfunctionChannelNumber | read-only | mandatory | The number of Function channels in the system. |
| 1.3.6.1.4.1.885.2.3 | NodelmsChannels | |||
| 1.3.6.1.4.1.885.2.3.1 | TablelmsBinaryChannelTable | not-accessible | mandatory | The table listing for the Binary channel information |
| 1.3.6.1.4.1.885.2.3.1.1 | RowlmsBinaryChannelEntry | not-accessible | mandatory | An entry containing information about a individual Binary channel. |
| 1.3.6.1.4.1.885.2.3.1.1.1 | ColumnbinaryChannelIndex | read-only | mandatory | The Binary channel number |
| 1.3.6.1.4.1.885.2.3.1.1.2 | ColumnbinaryChannelName | read-write | mandatory | The Binary channel name |
| 1.3.6.1.4.1.885.2.3.1.1.3 | ColumnbinaryChannelStatus | read-only | mandatory | The Binary channel state (CC=voltage applied) |
| 1.3.6.1.4.1.885.2.3.1.1.4 | ColumnbinaryChannelAlarmStatus | read-only | mandatory | The Binary channel alarm status |
| 1.3.6.1.4.1.885.2.3.1.1.5 | ColumnbinaryChannelAlarmClass | read-only | mandatory | The Binary channel alarm class |
| 1.3.6.1.4.1.885.2.3.2 | TablelmsAnalogChannelTable | not-accessible | mandatory | The table listing for the Analog channel information |
| 1.3.6.1.4.1.885.2.3.2.1 | RowlmsAnalogChannelEntry | not-accessible | mandatory | An entry containing information about an individual Analog channel. |
| 1.3.6.1.4.1.885.2.3.2.1.1 | ColumnanalogChannelIndex | read-only | mandatory | The Analog channel number |
| 1.3.6.1.4.1.885.2.3.2.1.2 | ColumnanalogChannelName | read-write | mandatory | The Analog channel name |
| 1.3.6.1.4.1.885.2.3.2.1.3 | ColumnanalogChannelValue | read-only | mandatory | The Analog channel reading |
| 1.3.6.1.4.1.885.2.3.2.1.4 | ColumnanalogChannelUnits | read-only | mandatory | The Analog channel reading units of measurement |
| 1.3.6.1.4.1.885.2.3.2.1.5 | ColumnanalogChannelLimit1 | read-only | mandatory | The Analog channel limit number one value |
| 1.3.6.1.4.1.885.2.3.2.1.6 | ColumnanalogChannelLimit2 | read-only | mandatory | The Analog channel limit number two value |
| 1.3.6.1.4.1.885.2.3.2.1.7 | ColumnanalogChannelLimit3 | read-only | mandatory | The Analog channel limit number three value |
| 1.3.6.1.4.1.885.2.3.2.1.8 | ColumnanalogChannelLimit4 | read-only | mandatory | The Analog channel limit number four value |
| 1.3.6.1.4.1.885.2.3.2.1.9 | ColumnanalogChannelAlarm | read-only | mandatory | The Analog channel alarm status |
| 1.3.6.1.4.1.885.2.3.3 | TablelmsRelayChannelTable | not-accessible | mandatory | The table listing for the Relay channel information |
| 1.3.6.1.4.1.885.2.3.3.1 | RowlmsRelayChannelEntry | not-accessible | mandatory | An entry containing information about an individual Relay channel. |
| 1.3.6.1.4.1.885.2.3.3.1.1 | ColumnrelayChannelIndex | read-only | mandatory | The Relay channel number |
| 1.3.6.1.4.1.885.2.3.3.1.2 | ColumnrelayChannelName | read-write | mandatory | The Relay channel name |
| 1.3.6.1.4.1.885.2.3.3.1.3 | ColumnrelayChannelStatus | read-write | mandatory | The Relay channel status (On, Forced, Programmed) |
| 1.3.6.1.4.1.885.2.3.3.1.4 | ColumnrelayChannelAlarmStatus | read-write | mandatory | The Relay channel alarm status |
| 1.3.6.1.4.1.885.2.3.3.1.5 | ColumnrelayChannelAlarmClass | read-write | mandatory | The Relay channel alarm class |
| 1.3.6.1.4.1.885.2.3.4 | TablelmsLEDChannelTable | not-accessible | mandatory | The table listing for the LED channel information |
| 1.3.6.1.4.1.885.2.3.4.1 | RowlmsLEDChannelEntry | not-accessible | mandatory | An entry containing information about an individual LED channel. |
| 1.3.6.1.4.1.885.2.3.4.1.1 | ColumnledChannelIndex | read-only | mandatory | The LED channel number |
| 1.3.6.1.4.1.885.2.3.4.1.2 | ColumnledChannelName | read-write | mandatory | The LED channel name |
| 1.3.6.1.4.1.885.2.3.4.1.3 | ColumnledChannelStatus | read-write | mandatory | The LED channel status (On, Forced, Programmed) |
| 1.3.6.1.4.1.885.2.3.4.1.4 | ColumnledChannelAlarmStatus | read-write | mandatory | The LED channel alarm status |
| 1.3.6.1.4.1.885.2.3.4.1.5 | ColumnledChannelAlarmClass | read-write | mandatory | The LED channel alarm class |
| 1.3.6.1.4.1.885.2.3.5 | TablelmsEnergyChannelTable | not-accessible | mandatory | The table listing for the Energy Management channel information |
| 1.3.6.1.4.1.885.2.3.5.1 | RowlmsEnergyChannelEntry | not-accessible | mandatory | An entry containing information about an individual Energy Management channel. |
| 1.3.6.1.4.1.885.2.3.5.1.1 | ColumnenergyChannelIndex | read-only | mandatory | The Energy Management channel number |
| 1.3.6.1.4.1.885.2.3.5.1.2 | ColumnenergyChannelName | read-write | mandatory | The Energy Management channel name |
| 1.3.6.1.4.1.885.2.3.5.1.3 | ColumnenergyCapacity | read-only | mandatory | The rated capacity of the rectifier associated with the Energy Management channel |
| 1.3.6.1.4.1.885.2.3.5.1.4 | ColumnenergyShunt | read-only | mandatory | The current load on the rectifier associated with the Energy Management channel |
| 1.3.6.1.4.1.885.2.3.5.1.5 | ColumnenergyRFA | read-only | mandatory | The current operational status of the rectifier associated with the Energy Management channel |
| 1.3.6.1.4.1.885.2.3.5.1.6 | ColumnenergyTR | read-only | mandatory | The current control status of the rectifier associated with the Energy Management channel |
| 1.3.6.1.4.1.885.2.3.6 | TablelmsFunctionChannelTable | not-accessible | mandatory | The table entry for a Function channel Alarm |
| 1.3.6.1.4.1.885.2.3.6.1 | RowlmsFunctionChannelEntry | not-accessible | mandatory | An entry containing the information returned by a Function channel Trap |
| 1.3.6.1.4.1.885.2.3.6.1.1 | ColumnfunctionChannelIndex | read-only | mandatory | The Function channel number |
| 1.3.6.1.4.1.885.2.3.6.1.2 | ColumnfunctionChannelName | read-write | mandatory | The Function channel name |
| 1.3.6.1.4.1.885.2.3.6.1.3 | ColumnfunctionChannelValue | read-only | mandatory | The Function channel reading |
| 1.3.6.1.4.1.885.2.3.6.1.4 | ColumnfunctionChannelUnits | read-only | mandatory | The Function channel reading units of measurement |
| 1.3.6.1.4.1.885.2.3.6.1.5 | ColumnfunctionChannelLimit1 | read-only | mandatory | The Function channel limit number one value |
| 1.3.6.1.4.1.885.2.3.6.1.6 | ColumnfunctionChannelLimit2 | read-only | mandatory | The Function channel limit number two value |
| 1.3.6.1.4.1.885.2.3.6.1.7 | ColumnfunctionChannelLimit3 | read-only | mandatory | The Function channel limit number three value |
| 1.3.6.1.4.1.885.2.3.6.1.8 | ColumnfunctionChannelLimit4 | read-only | mandatory | The Function channel limit number four value |
| 1.3.6.1.4.1.885.2.3.6.1.9 | ColumnfunctionChannelAlarm | read-only | mandatory | The Function channel alarm status |
| 1.3.6.1.4.1.885.2.5 | NodelmsTraps | |||
| 1.3.6.1.4.1.885.2.5.1 | TablelmsLedAlarmTable | not-accessible | mandatory | The table entry for a Led Alarm |
| 1.3.6.1.4.1.885.2.5.1.1 | RowlmsLedAlarmEntry | not-accessible | mandatory | An entry containing the information returned by a LED Trap |
| 1.3.6.1.4.1.885.2.5.1.1.1 | ColumnledAlarmIndex | read-only | mandatory | The LED channel number |
| 1.3.6.1.4.1.885.2.5.1.1.2 | ColumnledAlarmName | read-only | mandatory | The LED channel name |
| 1.3.6.1.4.1.885.2.5.1.1.3 | ColumnledAlarmStatus | read-only | mandatory | The LED channel status (On, Forced, Programmed) |
| 1.3.6.1.4.1.885.2.5.1.1.4 | ColumnledAlarmAlarmStatus | read-only | mandatory | The LED channel alarm status |
| 1.3.6.1.4.1.885.2.5.1.1.5 | ColumnledAlarmClass | read-only | mandatory | The LED channel alarm class |
| 1.3.6.1.4.1.885.2.5.1.1.6 | ColumnledAlarmReportType | read-only | mandatory | The LED channel alarm condition |
| 1.3.6.1.4.1.885.2.5.1.1.7 | ColumnledAlarmDuration | read-only | mandatory | The length of time the LED alarm has been active |
| 1.3.6.1.4.1.885.2.5.10 | TablelmsAnalogAlarmTable | not-accessible | mandatory | The table entry for an Analog channel Alarm |
| 1.3.6.1.4.1.885.2.5.10.1 | RowlmsAnalogAlarmEntry | not-accessible | mandatory | An entry containing the information returned by an Analog channel Trap |
| 1.3.6.1.4.1.885.2.5.10.1.1 | ColumnanalogAlarmIndex | read-only | mandatory | The Analog channel number |
| 1.3.6.1.4.1.885.2.5.10.1.2 | ColumnanalogAlarmName | read-only | mandatory | The Analog channel name |
| 1.3.6.1.4.1.885.2.5.10.1.3 | ColumnanalogAlarmValue | read-only | mandatory | The Analog channel reading |
| 1.3.6.1.4.1.885.2.5.10.1.4 | ColumnanalogAlarmUnits | read-only | mandatory | The Analog channel reading units of measurement |
| 1.3.6.1.4.1.885.2.5.10.1.5 | ColumnanalogAlarmLimitValue | read-only | mandatory | The Analog channel limit value |
| 1.3.6.1.4.1.885.2.5.10.1.6 | ColumnanalogAlarmLimitType | read-only | mandatory | The Analog channel limit type |
| 1.3.6.1.4.1.885.2.5.10.1.7 | ColumnanalogAlarmLimitName | read-only | mandatory | The Analog channel limit name |
| 1.3.6.1.4.1.885.2.5.10.1.8 | ColumnanalogAlarmLimitClass | read-only | mandatory | The Analog channel limit condition |
| 1.3.6.1.4.1.885.2.5.10.1.9 | ColumnanalogAlarmReportType | read-only | mandatory | The Analog channel limit condition |
| 1.3.6.1.4.1.885.2.5.10.1.10 | ColumnanalogAlarmDuration | read-only | mandatory | The length of time the Analog limit has been active |
| 1.3.6.1.4.1.885.2.5.11 | TablelmsBinaryAlarmTable | not-accessible | mandatory | The table entry for a Binary Alarm |
| 1.3.6.1.4.1.885.2.5.11.1 | RowlmsBinaryAlarmEntry | not-accessible | mandatory | An entry containing the information returned by a Binary Trap |
| 1.3.6.1.4.1.885.2.5.11.1.1 | ColumnbinaryAlarmIndex | read-only | mandatory | The Binary channel number |
| 1.3.6.1.4.1.885.2.5.11.1.2 | ColumnbinaryAlarmName | read-only | mandatory | The Binary channel name |
| 1.3.6.1.4.1.885.2.5.11.1.3 | ColumnbinaryAlarmStatus | read-only | mandatory | The Binary channel state (CC=voltage applied) |
| 1.3.6.1.4.1.885.2.5.11.1.4 | ColumnbinaryAlarmAlarmStatus | read-only | mandatory | The Binary channel alarm status |
| 1.3.6.1.4.1.885.2.5.11.1.5 | ColumnbinaryAlarmClass | read-only | mandatory | The Binary channel alarm class |
| 1.3.6.1.4.1.885.2.5.11.1.6 | ColumnbinaryAlarmReportType | read-only | mandatory | The Binary channel alarm condition |
| 1.3.6.1.4.1.885.2.5.11.1.7 | ColumnbinaryAlarmDuration | read-only | mandatory | The length of time the Binary alarm has been active |
| 1.3.6.1.4.1.885.2.5.12 | TablelmsFunctionAlarmTable | not-accessible | mandatory | The table entry for a Function channel Alarm |
| 1.3.6.1.4.1.885.2.5.12.1 | RowlmsFunctionAlarmEntry | not-accessible | mandatory | An entry containing the information returned by a Function channel Trap |
| 1.3.6.1.4.1.885.2.5.12.1.1 | ColumnfunctionAlarmIndex | read-only | mandatory | The Function channel number |
| 1.3.6.1.4.1.885.2.5.12.1.2 | ColumnfunctionAlarmName | read-only | mandatory | The Function channel name |
| 1.3.6.1.4.1.885.2.5.12.1.3 | ColumnfunctionAlarmValue | read-only | mandatory | The Function channel reading |
| 1.3.6.1.4.1.885.2.5.12.1.4 | ColumnfunctionAlarmUnits | read-only | mandatory | The Function channel reading units of measurement |
| 1.3.6.1.4.1.885.2.5.12.1.5 | ColumnfunctionAlarmLimitValue | read-only | mandatory | The Function channel limit value |
| 1.3.6.1.4.1.885.2.5.12.1.6 | ColumnfunctionAlarmLimitType | read-only | mandatory | The Function channel limit value |
| 1.3.6.1.4.1.885.2.5.12.1.7 | ColumnfunctionAlarmLimitName | read-only | mandatory | The Function channel limit name |
| 1.3.6.1.4.1.885.2.5.12.1.8 | ColumnfunctionAlarmLimitClass | read-only | mandatory | The Function channel alarm class |
| 1.3.6.1.4.1.885.2.5.12.1.9 | ColumnfunctionAlarmReportType | read-only | mandatory | The Function channel limit condition |
| 1.3.6.1.4.1.885.2.5.12.1.10 | ColumnfunctionAlarmDuration | read-only | mandatory | The length of time the Function limit has been active |
| 1.3.6.1.4.1.885.2.5.13 | TablelmsRelayAlarmTable | not-accessible | mandatory | The table entry for a Relay Alarm |
| 1.3.6.1.4.1.885.2.5.13.1 | RowlmsRelayAlarmEntry | not-accessible | mandatory | An entry containing the information returned by a Relay Trap |
| 1.3.6.1.4.1.885.2.5.13.1.1 | ColumnrelayAlarmIndex | read-only | mandatory | The Relay channel number |
| 1.3.6.1.4.1.885.2.5.13.1.2 | ColumnrelayAlarmName | read-only | mandatory | The Relay channel name |
| 1.3.6.1.4.1.885.2.5.13.1.3 | ColumnrelayAlarmStatus | read-only | mandatory | The Relay channel status (On, Forced, Programmed) |
| 1.3.6.1.4.1.885.2.5.13.1.4 | ColumnrelayAlarmAlarmStatus | read-only | mandatory | The Relay channel alarm status |
| 1.3.6.1.4.1.885.2.5.13.1.5 | ColumnrelayAlarmClass | read-only | mandatory | The Relay channel alarm class |
| 1.3.6.1.4.1.885.2.5.13.1.6 | ColumnrelayAlarmReportType | read-only | mandatory | The Relay channel alarm condition |
| 1.3.6.1.4.1.885.2.5.13.1.7 | ColumnrelayAlarmDuration | read-only | mandatory | The length of time the Relay alarm has been active |