MIB Viewer

LOG-MIB

35 objects
Modification: Date: 15 11 2002 Description: sagemDr replace sagem-dr NOTIFICATION-TYPE replace TRAP-TYPE Modification: Date: 20 12 1999 Description: Modification of comments Modification of trap re-notification quality-threshold-overflow replaced by performance. New Object: Date: 30 11 1999 Name: lostTrapBool,lostTrapBegin,lostTrapEnd,lostTrap Description: System of re-notification of lost traps, Name: LodEvent Description: Add of qualityThresholdOverflow (20), otherThresholdOverflow (21), maintenance (30) Name: probableCause Description: SIZE (0..20) replaced by SIZE (0..50) Creation: This MIB module describes alarmes and event log records. It also describes associated trap
Imported Objects
EQUIPMENT-MIBIntDateTime SagemBoolean Severity
SAGEM-DR-MIBIMPORTS sagemDr
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.1038.105IdentitylogModification: Date: 15 11 2002 Description: sagemDr replace sagem-dr NOTIFICATION-TYPE replace TRAP-TYPE Modification: Date: 20 12 1999 Description: Modificati…
1.3.6.1.4.1.1038.105.0NodelogTraps
1.3.6.1.4.1.1038.105.0.1NotificationlogTrapcurrentA trap of this type indicates that a threshold has been crossed in the corresponding interface/function. It also gives the date and time when the trap was sent…
1.3.6.1.4.1.1038.105.0.2NotificationthresholdTrapcurrentA trap of this type indicates that a threshold has been crossed in the corresponding interface/function. It also gives the date and time when the trap was sent…
1.3.6.1.4.1.1038.105.1ScalarlogClearread-writecurrentWhen a set command is issued on this variable the entire log event is cleared. This command is optional
1.3.6.1.4.1.1038.105.2ScalarlogCapacityread-onlycurrentThe maximum number of event in the log database
1.3.6.1.4.1.1038.105.3ScalarlogLastEventread-onlycurrentThe index of the last event number that have been logged. This is usefull for trap lost detection.
1.3.6.1.4.1.1038.105.4ScalarlogNumberread-onlycurrentNumber of current log in equipment.
1.3.6.1.4.1.1038.105.5TablelogTablenot-accessiblecurrentList of log trap that come from the equipment.
1.3.6.1.4.1.1038.105.5.1RowlogEntrynot-accessiblecurrentA particular log of the equipment.
1.3.6.1.4.1.1038.105.5.1.1ColumnlogIndexread-onlycurrentA unique value which identify a particular log entry. The index value cannot exced logCapacity and then returns to zero when the number of events exceds the ca…
1.3.6.1.4.1.1038.105.5.1.2ColumnlogDateread-onlycurrentWhen the event had happened.
1.3.6.1.4.1.1038.105.5.1.3ColumnlogObjectread-onlycurrentA reference to the function/interface who produced the event
1.3.6.1.4.1.1038.105.5.1.4ColumnlogNameread-onlycurrentA text string which identifies the particular entry among the log entries.
1.3.6.1.4.1.1038.105.5.1.5ColumnlogEventread-onlycurrentindicates the type of event which had occured
1.3.6.1.4.1.1038.105.5.1.6ColumnlogPCread-onlycurrentProbable cause. A short string which identifies the event type. For a failure it is its mnemonique.
1.3.6.1.4.1.1038.105.5.1.7ColumnlogAIread-onlycurrentA short string which gives additional information on the event
1.3.6.1.4.1.1038.105.5.1.8ColumnlogEquipStatusV2read-onlycurrentlogEquipStatusV2 is the value of equipStatusV2 stored in logTable each time a trap is sent
1.3.6.1.4.1.1038.105.6ScalarlogTrapEnableread-writecurrentWhen set to false the equipment stops to send logTraps. It has no effect on event log recording. It also has no effects on quality traps and on status trap use…
1.3.6.1.4.1.1038.105.7NodelostTrap
1.3.6.1.4.1.1038.105.7.1ScalarresendTrapBoolread-writecurrentThe manager set this variable to receive all the current traps of the equipment. The equipment must use resentLogTrap and resentNetworkAlarmeTrap to do it(not …
1.3.6.1.4.1.1038.105.101ScalarlogCurrentClearread-writecurrentWhen a set command is issued on this variable the entire log event is cleared. This command is optional
1.3.6.1.4.1.1038.105.102ScalarlogCurrentCapacityread-onlycurrentThe maximum number of event in the log database This variable is optional
1.3.6.1.4.1.1038.105.103ScalarlogCurrentLastEventread-onlycurrentThe index of the last current alarm number that have been logged. This variable is optional
1.3.6.1.4.1.1038.105.104ScalarlogCurrentNumberread-onlycurrentNumber of current log in equipment.
1.3.6.1.4.1.1038.105.105TablelogCurrentTablenot-accessiblecurrentList of log trap that come from the equipment.
1.3.6.1.4.1.1038.105.105.1RowlogCurrentEntrynot-accessiblecurrentA particular log of the equipment.
1.3.6.1.4.1.1038.105.105.1.1ColumnlogCurrentIndexread-onlycurrentA unique value which identify a particular logCurrent entry. The index value is comprised between 1 and logCurrentNumber. There is no relation between the inde…
1.3.6.1.4.1.1038.105.105.1.2ColumnlogCurrentDateread-onlycurrentWhen the event had happened.
1.3.6.1.4.1.1038.105.105.1.3ColumnlogCurrentObjectread-onlycurrentA reference to the function/interface who produced the event
1.3.6.1.4.1.1038.105.105.1.4ColumnlogCurrentNameread-onlycurrentA text string which identifies the particular entry among the log entries.
1.3.6.1.4.1.1038.105.105.1.5ColumnlogCurrentEventread-onlycurrentindicates the type of event which had occured
1.3.6.1.4.1.1038.105.105.1.6ColumnlogCurrentPCread-onlycurrentProbable cause. A short string which identifies the event type. For a failure it is its mnemonique.
1.3.6.1.4.1.1038.105.105.1.7ColumnlogCurrentAIread-onlycurrentA short string which gives additional information on the event
1.3.6.1.4.1.1038.105.105.1.8ColumnlogCurrentStatusV2read-onlycurrentlogEquipStatusV2 is the value of equipStatusV2 stored in logTable each time a trap is sent