MIB Viewer

LS100-MIB

77 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC1155-SMICounter enterprises
OIDNameAccessStatusDescription
1.3.6.1.4.1.119Nodenec
1.3.6.1.4.1.119.2Nodenec-mib
1.3.6.1.4.1.119.2.3NodenecProductDepend
1.3.6.1.4.1.119.2.3.14Nodeatomis-mib
1.3.6.1.4.1.119.2.3.14.3Nodem5core-mib
1.3.6.1.4.1.119.2.3.14.3.1Nodenode
1.3.6.1.4.1.119.2.3.14.3.1.1ScalarnodeOperStatusread-onlymandatoryOperational status of the LS100.
1.3.6.1.4.1.119.2.3.14.3.1.2TablenodeIfConfTablenot-accessiblemandatoryThe configuration of the line cards.
1.3.6.1.4.1.119.2.3.14.3.1.2.1RownodeIfConfEntrynot-accessiblemandatoryThe configuration of a line card.
1.3.6.1.4.1.119.2.3.14.3.1.2.1.1ColumnnodeIfConfIndexread-onlymandatoryThe index of the table. Same as ifIndex.
1.3.6.1.4.1.119.2.3.14.3.1.2.1.2ColumnnodeIfConfPhysTyperead-onlymandatoryThe PMD/physical layer format of the line card.
1.3.6.1.4.1.119.2.3.14.3.1.2.1.3ColumnnodeIfConfRevread-onlymandatoryThe revision of the line cards.
1.3.6.1.4.1.119.2.3.14.3.1.2.1.4ColumnnodeIfConfStatusread-onlymandatoryOperational status of the line card.
1.3.6.1.4.1.119.2.3.14.3.1.3ScalarnodeFanStatusread-onlymandatoryOperational status of the Fan.
1.3.6.1.4.1.119.2.3.14.3.1.4ScalarnodeUpcWindowSizeread-writemandatoryUPC window size. Integer Wi represents Wi X 512 cell time. Wi=1 correspond to 1.4msec. Wi=120 correspond to 168msec. It is not allowed to change window size wh…
1.3.6.1.4.1.119.2.3.14.3.1.5ScalarnodeBestEffortBufferSizeread-writemandatoryInput buffer capacity for Best Effort traffic(Bb). The number of cells stored in the buffer is Bb X 128. The default value is 8. The sum of the buffer capacity…
1.3.6.1.4.1.119.2.3.14.3.1.6ScalarnodeGuaranteedBufferSizeread-writemandatoryInput buffer capacity for Guaranteed traffic(Bg). The number of cells stored in the buffer is Bg X 128. The default value is 0. The sum of the buffer capacity …
1.3.6.1.4.1.119.2.3.14.3.1.7ScalarnodeBestEffortBufferThresholdread-writemandatoryThreshold buffer capacity for Best Effort traffic. If the number of cells stored in the buffer exceeds this threshold, cells with CLP=1 and traffic defined as …
1.3.6.1.4.1.119.2.3.14.3.1.8ScalarnodeGuaranteedBufferThresholdread-writemandatoryThreshold buffer capacity for Guaranteed traffic. If the number of cells stored in the buffer exceeds this threshold, cells with CLP=1 and traffic defined as V…
1.3.6.1.4.1.119.2.3.14.3.1.9ScalarnodeSaveConfread-writemandatorySave system configuration information including the PVC table to the non-volatile memory. Writing a value of save(1) saves the configiration data. Writing the …
1.3.6.1.4.1.119.2.3.14.3.1.10ScalarnodeSaveResultread-onlymandatoryIndicates the result of the save command issued from NMS. The result is either success/temporary failure/notReady.
1.3.6.1.4.1.119.2.3.14.3.1.11ScalarnodeResetread-writemandatoryWriting the value reset(1) resets the system. Writing the value noOperation(2) has no effect. When read, this object always has the value noOperation(2).
1.3.6.1.4.1.119.2.3.14.3.2Nodelinf
1.3.6.1.4.1.119.2.3.14.3.2.1TablelinfStatusTablenot-accessiblemandatoryStatus of the line cards including ATM specific information.
1.3.6.1.4.1.119.2.3.14.3.2.1.1RowlinfStatusEntrynot-accessiblemandatoryStatus of a line card including ATM specific information.
1.3.6.1.4.1.119.2.3.14.3.2.1.1.1ColumnlinfIndexread-onlymandatorySame as ifIndex
1.3.6.1.4.1.119.2.3.14.3.2.1.1.2ColumnlinfStatusread-onlymandatoryStatus of line interface
1.3.6.1.4.1.119.2.3.14.3.2.1.1.3ColumnlinfConfread-writemandatoryLine card type.
1.3.6.1.4.1.119.2.3.14.3.2.1.1.4ColumnlinfFwdAvailableBandWidthread-onlymandatoryThe amount of bandwidth (Mbps) available/unallocated in the forward (incoming) direction.
1.3.6.1.4.1.119.2.3.14.3.2.1.1.5ColumnlinfBkwdAvailableBandWidthread-onlymandatoryThe amount of bandwidth (Mbps) available/unallocated in the backward (outgoing) direction.
1.3.6.1.4.1.119.2.3.14.3.3Nodeconn
1.3.6.1.4.1.119.2.3.14.3.3.1ScalarconnPvcIndexNextread-onlymandatoryThe next available index for a row of the connPvcTable.
1.3.6.1.4.1.119.2.3.14.3.3.2ScalarconnPvcIndexEnableread-writedeprecatedWhen read, this object is the current minimum value of an index in the connPvcTable. Writing this value has no effect.
1.3.6.1.4.1.119.2.3.14.3.3.3TableconnPvcTablenot-accessiblemandatoryThe table containing information on current PVC/SVCs. Currently, only PVCs are represented in this table. The table is also used to establish and delete PVCs. …
1.3.6.1.4.1.119.2.3.14.3.3.3.1RowconnPvcEntrynot-accessiblemandatoryA row in the table is used to show the current PVC/SVCs.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.1ColumnconnPvcIndexread-onlymandatoryA unique value to identify this point-to-point or point-to-multipoint connection. A point-to-multipoint connection has multiple rows in this table, one for eac…
1.3.6.1.4.1.119.2.3.14.3.3.3.1.2ColumnconnPvcTopologyread-writemandatoryTopology of the connection.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.3ColumnconnPvcTrafficTyperead-writemandatoryTraffic Type.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.4ColumnconnPvcLowIfIndexread-writemandatoryThe line interface number (ifIndex) of the low port. Normally, the low port has a lower ifIndex value than the high port. However, for point-to-multipoint conn…
1.3.6.1.4.1.119.2.3.14.3.3.3.1.5ColumnconnPvcLowVPIread-writemandatoryVPI value of the connection on the low port.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.6ColumnconnPvcLowVCIread-writemandatoryVCI value of the connection on the low port.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.7ColumnconnPvcLowUpcParamread-writemandatoryNumber of cells allowed to be sent in the unit cell time (512 cell times).
1.3.6.1.4.1.119.2.3.14.3.3.3.1.8ColumnconnPvcLowUpcread-writemandatoryThe action to take on a UPC violation for this connection on the low port. The tagging action is not supported by current hardware.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.9ColumnconnPvcLowThroughputread-writemandatoryAverage rate of the connection (Mbps). Direction is from the low port to high port. This parameter is valid for the connection whose traffic type is CBR or VBR.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.10ColumnconnPvcHighIfIndexread-onlymandatoryThe line interface number (ifIndex) of the high port. Normally, the high port has a higher ifIndex value than the low port. However, for point-to-multipoint co…
1.3.6.1.4.1.119.2.3.14.3.3.3.1.11ColumnconnPvcHighVPIread-writemandatoryThe VPI value of the connection on the high port.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.12ColumnconnPvcHighVCIread-writemandatoryThe VCI value of the connection on the high port.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.13ColumnconnPvcHighUpcParamread-writemandatoryNumber of cells allowed to be sent in the unit cell time (512 cell times).
1.3.6.1.4.1.119.2.3.14.3.3.3.1.14ColumnconnPvcHighUpcread-writemandatoryThe action to take on a UPC violation for this connection on the high port. The tagging action is not supported by current hardware.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.15ColumnconnPvcHighThroughputread-writemandatoryAverage rate of the connection (Mbps). Direction is from the high port to low port. This parameter is valid for the connection whose traffic type is CBR or VBR.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.16ColumnconnPvcLowInCellsread-onlymandatoryNumber of incoming cells on this connection on low port.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.17ColumnconnPvcHighOutCellsread-onlymandatoryNumber of outgoing cells on this connection on the high port.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.18ColumnconnPvcHighInCellsread-onlymandatoryNumber of incoming cells on this connection on high port. (Valid for bi-direction connections only).
1.3.6.1.4.1.119.2.3.14.3.3.3.1.19ColumnconnPvcLowOutCellsread-onlymandatoryNumber of outgoing cells on this connection on the low. port. (Valid for bi-direction connections only).
1.3.6.1.4.1.119.2.3.14.3.3.3.1.20ColumnconnPvcLowUpcViolatedCellsread-onlymandatoryNumber of UPC violation cells incoming from the low port.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.21ColumnconnPvcHighUpcViolatedCellsread-onlymandatoryNumber of UPC violation cells incoming from the high port. (Valid for bi-direction connections only).
1.3.6.1.4.1.119.2.3.14.3.3.3.1.22ColumnconnPvcRowStatusread-writemandatoryThe status of this row. 'active' indicates that the connection is in use. 'notInService' indicates that the row exists but the connection is not established. '…
1.3.6.1.4.1.119.2.3.14.3.3.3.1.23ColumnconnPvcCauseread-onlymandatoryThe result of the PVC establishment/deletion.
1.3.6.1.4.1.119.2.3.14.3.3.3.1.24ColumnconnPvcKindread-onlymandatoryThis object identifies the connection is SVC or PVC.
1.3.6.1.4.1.119.2.3.14.3.4Nodeperf
1.3.6.1.4.1.119.2.3.14.3.4.1ScalarperfTrapEnableread-writemandatoryThe status of performance monitoring traps. Its value does not affect other traps, such as coldStart.
1.3.6.1.4.1.119.2.3.14.3.4.2TableperfIfTablenot-accessiblemandatoryTable of performance monitoring information.
1.3.6.1.4.1.119.2.3.14.3.4.2.1RowperfIfEntrynot-accessiblemandatoryPerformance monitoring information for a specific line.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.1ColumnperfIfIndexread-onlymandatoryLine interface number. Same as ifIndex.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.2ColumnperfIfLcvsread-onlymandatoryLine Code Violation. This object is valid only for DS3/E3.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.3ColumnperfIfParitySectionsread-onlymandatoryNumber of B1 (BIP) errors(OC-3c, UTP-5), Number of C-bit parity violation(DS3), Number of CRC-6 violation(DS1).
1.3.6.1.4.1.119.2.3.14.3.4.2.1.4ColumnperfIfParityLinesread-onlymandatoryNumber of B2 (BIP) errors(OC-3c, UTP-5), Number of P-bit parity violation(DS3).
1.3.6.1.4.1.119.2.3.14.3.4.2.1.5ColumnperfIfParityPathsread-onlymandatoryNumber of B3 (BIP) errors(OC-3c, UTP-5), Number of PLCP BIP violation(DS3).
1.3.6.1.4.1.119.2.3.14.3.4.2.1.6ColumnperfIfHecErrorsread-onlymandatoryNumber of HEC errors detected.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.7ColumnperfIfMisDelivdCellsread-onlymandatoryNumber of misdelivered cells.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.8ColumnperfIfOverFlowCellsread-onlymandatoryNumber of cells discarded due to buffer overflow.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.9ColumnperfIfInCBRCellsread-onlymandatoryNumber of received CBR cells.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.10ColumnperfIfOutCBRCellsread-onlymandatoryNumber of transmitted CBR cells.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.11ColumnperfIfInVBRCellsread-onlymandatoryNumber of received VBR cells.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.12ColumnperfIfOutVBRCellsread-onlymandatoryNumber of transmitted VBR cells.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.15ColumnperfIfInUBRCellsread-onlymandatoryNumber of received UBR cells.
1.3.6.1.4.1.119.2.3.14.3.4.2.1.16ColumnperfIfOutUBRCellsread-onlymandatoryNumber of transmitted UBR cells.