LSI-MegaRAID-SAS-MIB

620 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMICounter enterprises Gauge private
RFC1213-MIBDisplayString PhysAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.3582Nodelsi
1.3.6.1.4.1.3582.4NodestorageComponents
1.3.6.1.4.1.3582.4.1NodelsiRAIDServer
1.3.6.1.4.1.3582.4.1.1ScalarhostNameread-onlymandatoryName of the host system.
1.3.6.1.4.1.3582.4.1.2ScalarhostOSInforead-onlymandatoryOperating System description where SNMP agent is running.
1.3.6.1.4.1.3582.4.1.3NodeversionInfo
1.3.6.1.4.1.3582.4.1.3.1ScalarmibVersionread-onlymandatoryThe MIB version no. (xx.yy)
1.3.6.1.4.1.3582.4.1.3.2ScalaragentModuleNameread-onlymandatoryThe agent module name
1.3.6.1.4.1.3582.4.1.3.3ScalaragentModuleVersionread-onlymandatoryThe module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information).
1.3.6.1.4.1.3582.4.1.3.4ScalarreleaseDateread-onlymandatoryModule Release Date
1.3.6.1.4.1.3582.4.1.4NodemegaRAID-SAS
1.3.6.1.4.1.3582.4.1.4.1Nodeadapter
1.3.6.1.4.1.3582.4.1.4.1.1ScalaradpNumberread-onlymandatoryThe total no of SAS adapters present.
1.3.6.1.4.1.3582.4.1.4.1.2TableadapterPropertiesTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters.
1.3.6.1.4.1.3582.4.1.4.1.2.1RowadapterPropertiesEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.4.1.4.1.2.1.1ColumnadapterID-APTread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.4.1.4.1.2.1.2ColumnrebuildRateread-writeoptionalRebuild rate on this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.3ColumnreconstructionRateread-writeoptionalReconstruction rate on this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.4ColumnalarmStateread-writeoptionalAlarm is enabled or disabled on this adapter. Values: disabled(0),enabled(1)
1.3.6.1.4.1.3582.4.1.4.1.2.1.5ColumncacheFlushIntervalread-onlyoptionalCache flush interval in seconds for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.6ColumnclusterStateread-onlyoptionalCluster is enabled or disabled on this adapter. Values: disabled(0),enabled(1)
1.3.6.1.4.1.3582.4.1.4.1.2.1.7ColumnpredFailPollIntervalread-writeoptionalNumber of seconds between precdictive fail polls on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.8ColumnintThrottleCountread-writeoptionalInterrupt throttle active count on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.9ColumnintThrottleTimeUsread-writeoptionalInterrupt throttle completion hold time on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.10ColumnpatrolReadRateread-writeoptionalPatrol Read Rate for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.11ColumnbgiRateread-writeoptionalBackground initialization rate for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.12ColumnspinupDelayread-writeoptionalNumber of seconds to delay among spinup groups for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.13ColumnspinupDriveCountread-writeoptionalMaximum number of drives to spin up at one time for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.14ColumncoercionModeread-onlyoptionalDrive capacity coercion mode. 0->None; 1->128MB; 2->1GB
1.3.6.1.4.1.3582.4.1.4.1.2.1.15ColumnnvramSizeread-onlyoptionalNVRAM size in KB for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.16ColumnmemorySizeread-onlyoptionalMemory size in MB for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.17ColumnflashSizeread-onlyoptionalFlash size in MB for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.18ColumnvdPresentCountread-onlyoptionalVirtual devices present in this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.19ColumnvdDegradedCountread-onlyoptionalNumber of virtual devices in this adapter that are critical
1.3.6.1.4.1.3582.4.1.4.1.2.1.20ColumnvdOfflineCountread-onlyoptionalNumber of virtual devices in this adapter that are offline
1.3.6.1.4.1.3582.4.1.4.1.2.1.21ColumnpdPresentCountread-onlyoptionalPhysical devices present in this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.22ColumnpdDiskPresentCountread-onlyoptionalPhysical disk devices present in this adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.23ColumnpdDiskPredFailureCountread-onlyoptionalNumber of disk devices in this adapter that are critical
1.3.6.1.4.1.3582.4.1.4.1.2.1.24ColumnpdDiskFailedCountread-onlyoptionalNumber of disk devices in this adapter that are failed
1.3.6.1.4.1.3582.4.1.4.1.2.1.25ColumnccRateread-writeoptionalConsistency Check rate on this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.26ColumncompatibilityFlagread-onlyoptionalTo inform compatibilities between Applications and FW. 0->incompatible; 1->compatible
1.3.6.1.4.1.3582.4.1.4.1.2.1.27ColumncompatibilityInforead-onlyoptionalCompatibility Information. Format->(Firmware Forward compatibility flag:Firmware Backward compatibility flag:Firmware version flag:Application Forward compatib…
1.3.6.1.4.1.3582.4.1.4.1.2.1.28ColumnabortCConErrorread-writeoptionalAbort CC on detecting error is enabled or disabled on this adapter. Values: No(0),Yes(1),NA(2)
1.3.6.1.4.1.3582.4.1.4.1.2.1.29ColumncopyBackStateread-onlyoptionalCopyBack is enabled or disabled on this adapter.Values: disabled(0),enabled(1)
1.3.6.1.4.1.3582.4.1.4.1.2.1.30ColumnrevisionIdentifierread-onlyoptionalBoard revision ID for this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.2.1.31ColumnmultipathSupportread-onlyoptionalMultipath is supported or not supported on this adapter.Values: not supported(0),supported(1)
1.3.6.1.4.1.3582.4.1.4.1.2.1.32ColumnssdSMARTerEnabledread-onlyoptionalCopyback to SSD on SMART error. Values Enabled(0),Disabled(1)
1.3.6.1.4.1.3582.4.1.4.1.2.1.33ColumnenableSpinDownUnconfiguredread-onlyoptionalSpin Down Unconfigured Drives(1), Do Not Spin Down Unconfigured Drives(0)
1.3.6.1.4.1.3582.4.1.4.1.2.1.34ColumndisableSpinDownHotSpareread-onlyoptionalSpin Down Hotspares(0), Do Not Spin Down Hotspares(1)
1.3.6.1.4.1.3582.4.1.4.1.2.1.35ColumnspinDownTimeread-onlyoptionalSpinDownTime in minutes
1.3.6.1.4.1.3582.4.1.4.1.2.1.36ColumnspinupEnclDriveCountread-onlyoptionalMaximum number of drives that can be spin up in an enclosure
1.3.6.1.4.1.3582.4.1.4.1.2.1.37ColumnspinupEnclDelayread-onlyoptionalDelay between drive spin up for drives within an enclosure
1.3.6.1.4.1.3582.4.1.4.1.2.1.38ColumndefaultLdPSPolicyread-onlyoptionalpower saving policy.values:controller default power saving policy=0, AUTO=1, MAX=2, Max with no cache=6, NONE=255
1.3.6.1.4.1.3582.4.1.4.1.2.1.39ColumndisableLdPSIntervalread-onlyoptionalLD power savings are disabled for yy hours beginning at disableLdPSTime.
1.3.6.1.4.1.3582.4.1.4.1.2.1.40ColumndisableLdPSTimeread-onlyoptionalLD power savings shall be disabled at xx minutes from 12:00am.
1.3.6.1.4.1.3582.4.1.4.1.2.1.41ColumnsupportBreakMirrorread-onlyoptional1=Support break mirror operation,0=Do not Support break mirror operation
1.3.6.1.4.1.3582.4.1.4.1.2.1.42ColumntemperatureROCread-onlyoptionaltemperature of RAID On Chip in Celsius
1.3.6.1.4.1.3582.4.1.4.1.2.1.43ColumntemperatureCtrlread-onlyoptionaltemperature of controller in Celsius
1.3.6.1.4.1.3582.4.1.4.1.2.1.44ColumnpreventPIImportread-onlyoptional1=Prevent import of SAS PI protected logical disks , 0=Not Prevent import of SAS PI protected logical disks
1.3.6.1.4.1.3582.4.1.4.1.2.1.45ColumnenablePIread-onlyoptional1 = Enable SAS PI for controller , 0 = Disable SAS PI for controller
1.3.6.1.4.1.3582.4.1.4.1.2.1.46ColumntotalSpaceformetadataread-onlyoptionalTotal Space used for MetaData
1.3.6.1.4.1.3582.4.1.4.1.2.1.47ColumnuseEmergencySpareread-onlyoptionalThis field give the information about Emergency Spare possible Drive types(Uncongiured Good/Global Hotspare)
1.3.6.1.4.1.3582.4.1.4.1.2.1.48ColumnuseEmergencySparesforSMARTerread-onlyoptional1 = Use Emergency spares for SMARTer ,0 = Not Use Emergency spares for SMARTer
1.3.6.1.4.1.3582.4.1.4.1.2.1.49ColumnsupportShieldStateread-onlyoptional1 =Support PD shield state ,0 = Not Support PD shield state
1.3.6.1.4.1.3582.4.1.4.1.2.1.50ColumnwriteCacheCapableread-onlyoptional1 = SSC support write caching IOs ,0 = SSC not support write caching IOs
1.3.6.1.4.1.3582.4.1.4.1.2.1.51ColumntotalCacheSizeread-onlyoptionalThis field give the information about total Size of currently configured SSC,in GB
1.3.6.1.4.1.3582.4.1.4.1.2.1.52ColumnmaximumCacheSizeread-onlyoptionalThis field give the information about maxmium Size of SSC that can yet be configured,in GB
1.3.6.1.4.1.3582.4.1.4.1.2.1.53ColumnctrlSasAddrread-onlyoptionalThis field gives the controller SAS address
1.3.6.1.4.1.3582.4.1.4.1.2.1.54ColumndomainIdread-onlyoptionalThis field gives the Domain ID
1.3.6.1.4.1.3582.4.1.4.1.2.1.55ColumnpeerControllerStatusread-onlyoptionalThis field gives the Peer controller Status
1.3.6.1.4.1.3582.4.1.4.1.2.1.56ColumnmaximumControllerNodesread-onlyoptionalThis field gives the HA nodes this FW supports
1.3.6.1.4.1.3582.4.1.4.1.2.1.57ColumnincompatibilityDetailsread-onlyoptionalThis field gives the Incompatibility Details
1.3.6.1.4.1.3582.4.1.4.1.2.1.58ColumntopologyTyperead-onlyoptionalThis field gives the Topology Type
1.3.6.1.4.1.3582.4.1.4.1.2.1.59ColumnsupportOnlineFWUpdateread-onlyoptional1 = Online firmware update is supported, 0 = Online firmware update is not supported
1.3.6.1.4.1.3582.4.1.4.1.2.1.60ColumnsupportFastPathWBread-onlyoptional1 = Support Fast Path WB on Raptor Type Ld ,0 = Does not support Fast Path WB on Raptor Type Ld
1.3.6.1.4.1.3582.4.1.4.1.2.1.61ColumnsupportConfigAutoBalanceread-onlyoptional0 = no configuration auto balance support, 1 = configuration auto balance support is present
1.3.6.1.4.1.3582.4.1.4.1.2.1.62ColumnmaintenanceModeread-onlyoptional1=FW supports maintenance mode
1.3.6.1.4.1.3582.4.1.4.1.2.1.63ColumndisableLargeIOread-onlyoptional0 = Large IO is supported, 1 = Large IO is unsupported
1.3.6.1.4.1.3582.4.1.4.1.3TableadapterInfoTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters on the Controller.
1.3.6.1.4.1.3582.4.1.4.1.3.1RowadapterInfoEntrynot-accessiblemandatoryAn Entry in the adapterInfo table.
1.3.6.1.4.1.3582.4.1.4.1.3.1.1ColumnadapterID-AITread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.4.1.4.1.3.1.2ColumnadapterVendorIDread-onlyoptionalPCI Vendor ID for this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.3.1.3ColumndevIDread-onlyoptionalPCI Device ID for this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.3.1.4ColumnsubVendorIDread-onlyoptionalPCI Sub-Vendor ID for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.3.1.5ColumnsubDevIDread-onlyoptionalPCI Sub-Device ID for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.3.1.6ColumnhostInterfaceread-onlyoptionalHost interface information for this adapter. Values: N/A(0),PCIX(1),PCIE(2),iSCSI(3),SAS-3G(4)
1.3.6.1.4.1.3582.4.1.4.1.3.1.7ColumnhostInterfacePortCntread-onlyoptionalPort Count on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.3.1.8ColumnhostInterfacePortAddrread-onlyoptionalPort address comma delimited
1.3.6.1.4.1.3582.4.1.4.1.3.1.9ColumndevInterfaceread-onlyoptionalMultiple device interface support values separated by space.
1.3.6.1.4.1.3582.4.1.4.1.3.1.10ColumndevInterfacePortCntread-onlyoptionalDevice Port Count on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.3.1.11ColumndevInterfacePortAddrread-onlyoptionalDevice Port address comma delimited
1.3.6.1.4.1.3582.4.1.4.1.3.1.12ColumnproductNameread-onlyoptionalProduct name e.g. MegaRAID SAS-8E, MegaRAID SAS-4X, etc.
1.3.6.1.4.1.3582.4.1.4.1.3.1.13ColumnserialNoread-onlyoptionalController serial number
1.3.6.1.4.1.3582.4.1.4.1.3.1.14ColumnfirmwareVersionread-onlyoptionalFirmware version Format->(Firmware Package Version:Version:Date:Time)
1.3.6.1.4.1.3582.4.1.4.1.3.1.15ColumndriverVersionread-onlyoptionalDriver version Format->(Driver Name:Version)
1.3.6.1.4.1.3582.4.1.4.1.3.1.16ColumnexpanderFirmwareVersionread-onlyoptionalExpander firmware version - Not Available if expander is not present on the controller
1.3.6.1.4.1.3582.4.1.4.1.3.1.17ColumnlockKeyBindingread-onlyoptionalType of lock key binding. lock key is not bound(0),lock key bound to FW secret key(1), lock key bound to user(2), lock key bound to a TPM(3)
1.3.6.1.4.1.3582.4.1.4.1.3.1.18ColumnmaxDAPdCountSpinup60read-onlyoptionalMaximum number of drives to spinup within 60 sec for direct attached drives
1.3.6.1.4.1.3582.4.1.4.1.4TableadapterSupportInfoTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters on the Controller.
1.3.6.1.4.1.3582.4.1.4.1.4.1RowadapterSupportInfoEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.4.1.4.1.4.1.1ColumnadapterID-ASITread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.4.1.4.1.4.1.2ColumnmaxArmsread-onlyoptionalMaximum arms per Virtual Drive supported for this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.4.1.3ColumnmaxSpansread-onlyoptionalMaximum spans per Virtual Drive supported for this Adapter.
1.3.6.1.4.1.3582.4.1.4.1.4.1.4ColumnmaxArraysread-onlyoptionalMaximum no of arrays supported for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.4.1.5ColumnmaxVDsread-onlyoptionalMaximum number of Virtual Drive s supported for this adapter.
1.3.6.1.4.1.3582.4.1.4.1.4.1.6ColumnhardwarePresentread-onlyoptionalSupported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4),TPM(5),expander(6). For multiple hw support a space delimited list will appear.
1.3.6.1.4.1.3582.4.1.4.1.4.1.7ColumnmaxConcurrentCmdsread-onlyoptionalThe maximum parallel commands supported on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.4.1.8ColumnmaxSGECountread-onlyoptionalThe maximum Scatter Gather Element count allowed on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.4.1.9ColumnmaxRequestSizeread-onlyoptionalThe maximum data transfer size in sectors, on this adapter.
1.3.6.1.4.1.3582.4.1.4.1.4.1.10ColumnmaxLdsPerArrayread-onlyoptionalMax Ld's per array in adapter
1.3.6.1.4.1.3582.4.1.4.1.4.1.11ColumnpartitionsInDDFread-onlyoptionalMax LD's per Array in configuration
1.3.6.1.4.1.3582.4.1.4.1.4.1.12ColumnallowSSDMixInLDread-onlymandatoryallow SAS/SATA SSD mix within an LD. allow(1), not allow(0)
1.3.6.1.4.1.3582.4.1.4.1.4.1.13ColumnallowMixSSDHDDInLDread-onlymandatoryallow SSD/HDD mix within an LD.allow(1), not allow(0)
1.3.6.1.4.1.3582.4.1.4.1.5TableadapterOperationsSupportInfoTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters on the Controller.
1.3.6.1.4.1.3582.4.1.4.1.5.1RowadapterOperationsSupportInfoEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.4.1.4.1.5.1.1ColumnadapterIDread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.4.1.4.1.5.1.2ColumnrbldRateSupportedread-onlyoptionalRebuilding rate change support for this Adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.3ColumnccRateSupportedread-onlyoptionalConsistency Check rate change support for this Adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.4ColumnbgiRateSupportedread-onlyoptionalBackground initialization rate change support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.5ColumnreconRateSupportedread-onlyoptionalReconstruction rate change support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.6ColumnpatrolRateSupportedread-onlyoptionalPatrol read rate change support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.7ColumnalarmControlSupportedread-onlyoptionalAlarm control support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.8ColumnclusterSupportedread-onlyoptionalCluster support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.9ColumnbbuSupportedread-onlyoptionalBBU support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.10ColumnspanningAllowedSupportedread-onlyoptionalSpanning support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.11ColumndedicatedHotSparesSupportedread-onlyoptionalDedicated HotSpares support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.12ColumnrevertibleHotSparesSupportedread-onlyoptionalRevertible HotSpares support for this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.13ColumnforeignConfigImportSupportedread-onlyoptionalSupport foreign config import on this adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.14ColumnselfDiagnosticSupportedread-onlyoptionalController supports self diagnostic. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.15ColumnallowMixedRedundancyOnArraySupportedread-onlyoptionalAllow different Virtual Disk on the same array to have different redundancy levels. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.16ColumnabortCConErrorSupportedread-onlyoptionalAbort CC on detecting error is supported on this adapter. Values: No(0),Yes(1)
1.3.6.1.4.1.3582.4.1.4.1.5.1.17ColumnsecuritySupportedread-onlyoptionalDisplays the security support. if supported (1) , not supported (0)
1.3.6.1.4.1.3582.4.1.4.1.5.1.18ColumnsupportPIcontrollerread-onlyoptionalDisplays the support PI. 1=LD SAS PI Type 0, 0=LD Not SAS PI Type 0
1.3.6.1.4.1.3582.4.1.4.1.6NodebbuInfo
1.3.6.1.4.1.3582.4.1.4.1.6.1ScalarbbuNumberread-onlymandatoryThe present number of rows in the BBU Table.
1.3.6.1.4.1.3582.4.1.4.1.6.2TablebbuTablenot-accessibleoptionalA List of BBU Entries containing Information/Properties about the BBU.
1.3.6.1.4.1.3582.4.1.4.1.6.2.1RowbbuEntrynot-accessiblemandatoryAn Entry in the BBU table.
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.1ColumnbbuIDread-onlyoptionalBBUID for this BBU.(Unique)
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.2ColumnbatteryTyperead-onlyoptionalBBU Type.
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.3ColumnnextLearnTimeread-onlyoptionalTime of next scheduled learn cycle (seconds past 1/1/2000)
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.4ColumnabsStateOfChargeread-onlyoptionalPredicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.5ColumnfullChargeCapacityread-onlyoptionalPredicted pack capacity when it is fully charged in joules
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.6ColumnaverageEmptyTimeread-onlyoptionalOne-minute rolling average of the predicted remaining battery life. Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.7ColumncycleCountread-onlyoptionalNumber of charge cycles the battery has experienced. Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.8ColumnfirmwareStatusread-onlyoptionalCondition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) …
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.9Columnvoltageread-onlyoptionalAccurate battery terminal voltage in mV, resolution of 1mV
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.10ColumnautoLearnPeriodread-onlyoptionalTime (in seconds) between learn cycles (0 to disable auto learn)
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.11ColumnrelStateOfChargeread-onlyoptionalPredicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.12ColumncapacityRemainread-onlyoptionalPredicted charge or energy remaining in the battery in joules
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.13ColumnrunTimeToEmptyread-onlyoptionalRelative gain or loss in remaining life in response to change in power policy represent in minute. Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.14ColumnavgTimeToFullread-onlyoptionalOne-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.15ColumnerrorMarginread-onlyoptionalExpected margin of error (%) in charge calculation (2-100). Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16Columntemperatureread-onlyoptionalBattery temperature in degree Centigrade
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.17ColumnmfgNameread-onlyoptionalBattery manufacturer's name
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.18ColumndeviceNameread-onlyoptionalBattery name
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.19ColumnserialNumberread-onlyoptionalBattery serialNumber
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20ColumnchargerStatusread-onlyoptionalBattery charger status. Values: N/A(-1), off(0), complete(1), progress(2)
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.21ColumnadpIDread-onlyoptionalThe adapter id where BBU is attached
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.22ColumnremainingCapAlarmread-onlyoptionalRemaining capacity to alarm. Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.23ColumnremainingTimeAlarmread-onlyoptionalRemaining time to alarm. Value of -1 means not supported
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.24Columnbbu-currentread-onlyoptionalCurrent(In mA) being supplied (or accepted) through the battery terminals
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.25ColumngasGaugeStatusread-onlyoptionalGas gauge status
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.26ColumnbbuFRUread-onlyoptionalbbu FRU
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27ColumnbatteryReplacementread-onlyoptionalThis property denotes whether the Battery needs to be replaced or not.1 =battery needs to be replaced ,0 =battery needs not to be replaced
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.28ColumnbbuRetentiontimeread-onlyoptionalThe total no. of hours the battery can support the current capacity reserve. Undefined(0),48 hours+(>48),the exact no of hours(<=48)
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.29ColumnbbuStateread-onlyoptionalThis property gives the Information about BBU state. Operational = if BBU is working fine, Non-Operational = if BBU is not working fine
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.30ColumnmemoryModuleFRUread-onlyoptionaltmm FRU
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.31ColumnbbumoduleVersionread-onlyoptionalBattery Firmware Version
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.32ColumnautoLearnModeread-onlyoptionalAutomatic Learn Mode
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.33ColumnchargingStatusread-onlyoptionalCharging Status
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.34Columncapacitanceread-onlyoptionalCapacitance
1.3.6.1.4.1.3582.4.1.4.1.7TablecommonDeviceInfoTablenot-accessibleoptionalA List of general Physical Disk info
1.3.6.1.4.1.3582.4.1.4.1.7.1RowcommonDeviceInfoEntrynot-accessiblemandatoryAn Entry in the CommonDeviceInfo table.
1.3.6.1.4.1.3582.4.1.4.1.7.1.1ColumnadapterID-CDITread-onlymandatoryUnique adapter ID
1.3.6.1.4.1.3582.4.1.4.1.7.1.2ColumnforceOnlineread-onlymandatoryPhysical drive force Online operation support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.3ColumnforceOfflineread-onlymandatoryPhysical drive force Offline operation support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.4ColumnforceRebuildread-onlymandatoryPhysical drive force Rebuild operation support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.5ColumnsupportsSASread-onlymandatorySAS physical drive support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.6ColumnsupportsSATAread-onlymandatorySATA physical drive support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.7ColumnallowMixInEnclosureread-onlymandatoryMix InEnclosure support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.8ColumnallowMixInVDread-onlymandatoryMixInVIRTUALDRIVE support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.9ColumnallowSataInClusterread-onlymandatorySataInCluster support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.4.1.4.1.7.1.10ColumnsetPowerStateForCfgread-onlymandatoryFW requires application to set power state before configuration changes. Required(1), Not Required(0)
1.3.6.1.4.1.3582.4.1.4.1.8TablecommonVirtualDeviceInfoTablenot-accessibleoptionalA List of general Virtual Drive info
1.3.6.1.4.1.3582.4.1.4.1.8.1RowcommonVirtualDeviceInfoEntrynot-accessiblemandatoryAn Entry in the CommonVirtualDeviceInfo table.
1.3.6.1.4.1.3582.4.1.4.1.8.1.1ColumnadapterID-CVDITread-onlymandatoryUnique adapter ID
1.3.6.1.4.1.3582.4.1.4.1.8.1.2ColumnsupportedReadPolicyread-onlymandatoryRead policy support. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.8.1.3ColumnsupportedWritePolicyread-onlymandatoryWrite policy support. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.8.1.4ColumnsupportedIOPolicyread-onlymandatoryIO policy support. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.8.1.5ColumnsupportedAccessPolicyread-onlymandatoryAccess policy support. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.8.1.6ColumnsupportedMinSizeread-onlymandatoryMinimum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.4.1.4.1.8.1.7ColumnsupportedMaxSizeread-onlymandatoryMaximum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.4.1.4.1.8.1.8Columnldbbmread-onlymandatory1=LD bad block management is enabled, 0=LD bad block management is not enabled
1.3.6.1.4.1.3582.4.1.4.1.9TableadapterStatusSupportInfoTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters on the Controller.
1.3.6.1.4.1.3582.4.1.4.1.9.1RowadapterStatusSupportInfoEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.4.1.4.1.9.1.1ColumnadapterID-ASSITread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.4.1.4.1.9.1.2ColumnlockKeyAssignedread-onlyoptionalLock key Assigned support for this Adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.9.1.3ColumnlockKeyFailedread-onlyoptionallock Key Failed support for this Adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.9.1.4ColumnlockKeyNotBackedupread-onlyoptionallock Key Not Backedup support for this Adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.9.1.5ColumnbiosNotDetectedread-onlyoptionalbios Not Detected support for this Adapter. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.1.9.1.6ColumncacheIsPinnedread-onlyoptional1=controller cache is pinned for missing or offline LDs
1.3.6.1.4.1.3582.4.1.4.1.10TableadapterLdOperationSupportInfoTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters on the Controller.
1.3.6.1.4.1.3582.4.1.4.1.10.1RowadapterLdOperationSupportInfoEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.4.1.4.1.10.1.1ColumnadapterID-ALSITread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.4.1.4.1.10.1.2ColumnallowCtrlEncryptionread-onlyoptionalif it is set (1) supports controller encryption
1.3.6.1.4.1.3582.4.1.4.2Nodedevice
1.3.6.1.4.1.3582.4.1.4.2.1NodephysicalDriveInfo
1.3.6.1.4.1.3582.4.1.4.2.1.1ScalarpdNumberread-onlymandatoryThe present number of rows in the physical drive table.
1.3.6.1.4.1.3582.4.1.4.2.1.2TablephysicalDriveTablenot-accessibleoptionalA List of physical drive Entries containing Information/Properties about the drives
1.3.6.1.4.1.3582.4.1.4.2.1.2.1RowphysicalDriveEntrynot-accessibleoptionalAn Entry in the Device Table.
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.1ColumnpdIndexread-onlyoptionalThe unique ID
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.2ColumnphysDevIDread-onlyoptionalThe Device ID
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.3ColumnoemSupportedread-onlyoptionalIs the drive supported by the OEM (OEM-specific checks). Values: notSupported(1), supported(0)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.4ColumnscsiDevTyperead-onlyoptionalType of this Device. Values: disk(0),tape(1),printer(2),processor(3),cdrom(5),scanner(6),optical(7),enclosure(13),dvd(10),unknown(31)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.5ColumnconnectedAdapterPortread-onlyoptionalAdapter port(s) to which the device is connected.
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.6ColumndeviceSpeedread-onlyoptionalMaximum supported speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.7ColumnmediaErrCountread-onlyoptionalError count of the device
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.8ColumnotherErrCountread-onlyoptionalOther error count of the device
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.9ColumnpredFailCountread-onlyoptionalPredictive fail count of the device
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.10ColumnpdStateread-onlyoptionalFirmware's interpretation of drive state. Values: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(…
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.11ColumndisabledForRemovalread-onlyoptionalIf true, drive is ready for removal. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.12ColumnlinkSpeedread-onlyoptionalNegotiated link speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.13ColumnpdSupportFlagsread-onlyoptional1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCS…
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.14ColumnsasAddrread-onlyoptionalDevice SAS addresses. Comma separeted for multiple address
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.15ColumnrawSizeread-onlyoptionalSize(MB) before COD and coercion
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.16ColumnnonCoercedSizeread-onlyoptionalSize(MB) after COD is reserved but before coercion
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.17ColumncoercedSizeread-onlyoptionalSize(MB) after COD is reserved and after coercion
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.18ColumnenclDeviceIdread-onlyoptionalEnclosure's device Id (in decimal); if device is not within enclosure value is -1
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.19ColumnenclIndexread-onlyoptionalFirmware internal enclosure index
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.20ColumnslotNumberread-onlyoptionalSlot number of this drive, if the Physical Disk is part of an enclosure then -1
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.21ColumnoperationProgressread-onlyoptionalOperation progress in %. e.g. Rebuild progress is 10%
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.22ColumnadpID-PDTread-onlyoptionalController id where this Physical Drive is attached
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.23ColumnoperationSupportread-onlyoptionalMakeOnline,MakeOffline,MakeFailed,MakeBad,MakeUncofigured, MakeSpare,RemoveSpare,replaceMissing,markMissing,startRebuild, stopRebuild,locate,pdclear,foreignImp…
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.24ColumnpdVendorIDread-onlyoptionalVendor ID
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.25ColumnpdProductIDread-onlyoptionalProduct ID
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.26ColumnpdFwversionread-onlyoptionalPD firmware version
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.27ColumndiskTyperead-onlyoptionalType of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.28ColumnpartnerDevIdread-onlyoptionalIf drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.29Columnmediatyperead-onlyoptionalMedia Type HDD(0),SSD(1),Solid state flash module(2)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.30ColumnpowerStateread-onlyoptionalPower condition of the device. Values are device is active(0),device is stopped(1),device is transitioning between power states(255)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.31Columnsecuredread-onlyoptional1=drive is secured, 0=not secured
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.32Columnlockedread-onlyoptional1=drive is locked, 0=unlocked
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.33Columnforeignread-onlyoptional1=drive is secured by a foreign lock key, 0=drive is not secured by a foreign lock key
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.34ColumnoemCertifiedread-onlyoptionalIs the drive certified by the OEM (OEM-specific checks). Values: notCertified(1), Certified(0)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.35ColumnforeignImportNotAllowedread-onlyoptional1=Drive is not allowed foreignImport operation, 0=Drive is allowed foreignImport operation
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36ColumnpdTemperatureread-onlyoptionalPhysical Drive temperature in Celsius
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.37ColumnpdSerialNumberread-onlyoptionalPhysical Drives serial number
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.38ColumnpiEligibleread-onlyoptionalProtection Information eligibility.1=drive can be used for PD Enabled LD , 0=drive can't be used for PD Enabled LD
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.39ColumnpiTyperead-onlyoptionalSAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS …
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.40ColumnpiFormattedread-onlyoptionalformatted for PI information. 1=drive is formatted for PI information, 0=no PI data.
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.41ColumnuserDataBlockSizeread-onlyoptionalNumber of bytes of user data in LBA
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.42ColumncommissionedSpareread-onlyoptionalYes = this PD is a commissioned spare, No = this PD is not a commissioned spare.
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.43ColumnemergencySpareread-onlyoptionalEligible = this PD is a emergency spare, Ineligible = this PD is not a emergency spare.
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.44ColumnshieldCounterread-onlyoptionalHow many times the shield diagnostics was run before it was marked failed
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.45ColumnshieldDiagCompletionTimeread-onlyoptionalLast successful Diagnostics completion time. 0 is N/A
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.46ColumnineligibleForSSCDread-onlyoptionalWhether PD cannot be used for an SSCD. PD can not be used for an SSCD(1), PD can be used for an SSCD(0)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.47ColumnineligibleForLdread-onlyoptionalWhether PD cannot be used for a regular LD. PD can not be used for a regular LD(1), PD can be used for a regular LD(0)
1.3.6.1.4.1.3582.4.1.4.2.1.2.1.48Columnserviceableread-onlyoptionalWhether PD is removeable for service. PD is removeable for service(1), PD is not removeable for service(0)
1.3.6.1.4.1.3582.4.1.4.3NodevirtualDevice
1.3.6.1.4.1.3582.4.1.4.3.1NodevdInfo
1.3.6.1.4.1.3582.4.1.4.3.1.1ScalarvdNumbersread-onlymandatoryThe present number of rows in the virtualDrive table.
1.3.6.1.4.1.3582.4.1.4.3.1.2TablevirtualDriveTablenot-accessibleoptionalA List of Virtual Drives Entries containing Information/Properties about the virtualDrive.
1.3.6.1.4.1.3582.4.1.4.3.1.2.1RowvirtualDriveEntrynot-accessibleoptionalAn Entry in the virtualDrive Table.
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.1ColumnvirtualDevIDread-onlyoptionalThe unique Virtual Drives ID
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.2Columnsizeread-onlyoptionalTotal size in MB of the drive
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.3ColumnclusterOwnerDeviceIdread-onlyoptionalVD owner's device Id
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.4ColumntargetIdread-onlyoptionalVirtual Drive target id (i.e. 0 to 63)
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.5Columnstateread-onlyoptionalThe Device state: Values: offline(0),partially-degraded(1),degraded(2),optimal(3)
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.6Columnnameread-onlyoptionalVirtual Drive name
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.7ColumndefaultCachePolicyread-onlyoptionalDefault cache policy settings. Values: WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cac…
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.8ColumnaccessPolicyread-onlyoptionalAccess policy settings. Values: access-rw(0), access-read-only(2), access-blocked(3)
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.9ColumndiskCachePolicyread-onlyoptionalPhysical disk cache policy. Values: unchanged(0),enable(1),disable(2)
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.10ColumnbgiStateread-onlyoptionalDisable/Enable Back Groung Initialization on this Virtual Drive. Values: disable(1),enable(0)
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.11Columnprlread-onlyoptionalPrimay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E), 21(RAID-5E), 31(Concatenation…
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.12ColumnrLQread-onlyoptionalRaid level qualifier
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.13ColumnsRLread-onlyoptionalSecondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned)
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.14ColumnstripeSizeread-onlyoptionalStripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.15ColumnnumDrivesread-onlyoptionalNumber of drivers per span
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.16ColumnspanDepthread-onlyoptionalNumber of spans. If only one array then it is considered as 1 span
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.17ColumninitStateread-onlyoptional0=no init, 1=quick init, 2=full init
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.18ColumnvdOperationProgressread-onlyoptionalProgress % for an operation / No operation in progress
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.19ColumncurrentCachePolicyread-onlyoptionalCache policy settings. Values:WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad…
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.20ColumnadapterID-VDTread-onlyoptionalAdapter ID
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.21ColumnencryptionTyperead-onlyoptionallogical drive encryption type. Values No Encryption(0), FDE drive encryption(1), Controller-based encryption(2)
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.22ColumnvdOperationSupportread-onlyoptionalstartFGI,stopFGI,startCC,stopCC,startRecon,deleteLD
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.23ColumnbadBlocksExistread-onlyoptional0 = LD bad block table is empty, 1 = LD bad block table is not empty
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.24ColumndefaultPSPolicyread-onlyoptionalPower Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.25ColumncurrentPSPolicyread-onlyoptionalPower Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.26ColumnbreakMirrorread-onlyoptionalBreak Mirror Policy set for this LD.Values:1=break mirror is allowed, 0=break mirror not is allowed
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.27ColumnjoinMirrorread-onlyoptionalJoin Mirror policy set for this LD.Values:1=join mirror is allowed, 0=join mirror not is allowed
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.28ColumnmirrorPdInforead-onlyoptionalMirror Info Property give the Information about mirror of PD and PD state respectively.
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.29ColumnvdPiTyperead-onlyoptionalInformation about logical drive protection type . No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(…
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.30ColumnmirrorDataSizeread-onlyoptionalTotal Space used for mirrorData or Parity information
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.31ColumncacheCadeTyperead-onlyoptional0= Non-CacheCade VD, 1= CacheCade Type is Read & Write, 2= CacheCade Type is Read only, 3= R1-EC
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.32ColumncurrentWritePolicyread-onlyoptionalCurrent write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBack
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.33ColumndefaultWritePolicyread-onlyoptionalDefault write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBack
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.34ColumnassociatedVDread-onlyoptionalThis property gives the Information about VD is Cached or VD is not cached.
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.35ColumnhostAccessPolicyread-onlyoptionalThis property gives the Host Access Policy
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.36Columnguidread-onlyoptionalThis property gives the LD GUID.
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.37ColumnfastPathWBEnabledread-onlyoptional0= FastPathWB disabled, not a Raptor like LD, 1= FastPathWB enabled, Raptor like LD
1.3.6.1.4.1.3582.4.1.4.3.1.2.1.38ColumnpeerHasNoAccessread-onlyoptionalPeer can't access this shared ld, not applicable for exclusive LD
1.3.6.1.4.1.3582.4.1.4.3.1.3TablevdSpanInfoTablenot-accessibleoptionalA List of span Entries containing Information/Properties vd span.
1.3.6.1.4.1.3582.4.1.4.3.1.3.1RowvdSpanInfoEntrynot-accessibleoptionalAn Entry in the vdSpan Table.
1.3.6.1.4.1.3582.4.1.4.3.1.3.1.1ColumnspanIDread-onlyoptionalThe unique Span ID
1.3.6.1.4.1.3582.4.1.4.3.1.3.1.2ColumnvdID-VSITread-onlyoptionalThe Virtual Device ID
1.3.6.1.4.1.3582.4.1.4.3.1.3.1.3ColumnstartBlockread-onlyoptionalSpan physical disk starting block
1.3.6.1.4.1.3582.4.1.4.3.1.3.1.4ColumnnumBlocksread-onlyoptionalSpan physical disk block count
1.3.6.1.4.1.3582.4.1.4.3.1.3.1.5ColumnvdSpanArrayRefread-onlyoptionalArray reference (index)
1.3.6.1.4.1.3582.4.1.4.3.1.3.1.6ColumnadapterID-VSITread-onlyoptionalAdapter ID
1.3.6.1.4.1.3582.4.1.4.3.4NodearrayInfo
1.3.6.1.4.1.3582.4.1.4.3.4.1ScalararrayNumberread-onlymandatoryThe present number of rows in the array table.
1.3.6.1.4.1.3582.4.1.4.3.4.2TablearrayTablenot-accessibleoptionalA List of array Entries containing Information/Properties about the arrays.
1.3.6.1.4.1.3582.4.1.4.3.4.2.1RowarrayEntrynot-accessibleoptionalAn Entry in the array Table.
1.3.6.1.4.1.3582.4.1.4.3.4.2.1.1ColumnarrayIDread-onlyoptionalThe unique array ID
1.3.6.1.4.1.3582.4.1.4.3.4.2.1.2ColumnarraySizeread-onlyoptionalSize in MB
1.3.6.1.4.1.3582.4.1.4.3.4.2.1.3ColumnarrayNumDrivesread-onlyoptionalNumber of drives for this array
1.3.6.1.4.1.3582.4.1.4.3.4.2.1.4ColumnarrayRefread-onlyoptionalTag for the array
1.3.6.1.4.1.3582.4.1.4.3.4.2.1.5ColumnpdListread-onlyoptionalSpace separated Physical Drive identification. e.g. {devID devID devID} etc
1.3.6.1.4.1.3582.4.1.4.3.4.2.1.6ColumnadapterID-ATread-onlyoptionalAdapter ID.
1.3.6.1.4.1.3582.4.1.4.3.5NodespareInfo
1.3.6.1.4.1.3582.4.1.4.3.5.1ScalarspareDevNumberread-onlymandatoryThe present number of rows in the sparepool table.
1.3.6.1.4.1.3582.4.1.4.3.5.2TablespareTablenot-accessibleoptionalA List of sparepool Entries containing Information/Properties about the spare drive
1.3.6.1.4.1.3582.4.1.4.3.5.2.1RowspareEntrynot-accessibleoptionalAn Entry in the sparepool Table.
1.3.6.1.4.1.3582.4.1.4.3.5.2.1.1ColumnspareIDread-onlyoptionalThe unique Device ID
1.3.6.1.4.1.3582.4.1.4.3.5.2.1.2ColumndeviceIdentificationread-onlyoptionalThe unique Device ID
1.3.6.1.4.1.3582.4.1.4.3.5.2.1.3ColumnspareTyperead-onlyoptionalSpare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable.
1.3.6.1.4.1.3582.4.1.4.3.5.2.1.4ColumnarrayCountread-onlyoptionalThe number of arrays to which the Physical Drive can be dedicated
1.3.6.1.4.1.3582.4.1.4.3.5.2.1.5ColumnarrayIDsread-onlyoptionalComma separated array ids. e.g. 2,4,5 etc
1.3.6.1.4.1.3582.4.1.4.3.5.2.1.6ColumnadapterID-STread-onlyoptionalAdapter ID.
1.3.6.1.4.1.3582.4.1.5NodeenclosureInfo
1.3.6.1.4.1.3582.4.1.5.1ScalarenclosureNumberread-onlymandatoryThe present number of rows in the enclosure table.
1.3.6.1.4.1.3582.4.1.5.2TableenclosureTablenot-accessibleoptionalA List of Enclosure Entries containing Information/Properties about the enclosures in the system.
1.3.6.1.4.1.3582.4.1.5.2.1RowenclosureEntrynot-accessiblemandatoryAn Entry in the enclosure table.
1.3.6.1.4.1.3582.4.1.5.2.1.1ColumnenclosureIDread-onlyoptionalEnclosureID for this enclosure.(Unique)
1.3.6.1.4.1.3582.4.1.5.2.1.2ColumndeviceIdread-onlyoptionalEnclosure device Id.
1.3.6.1.4.1.3582.4.1.5.2.1.3ColumnenclosureIndexread-onlyoptionalFirmware internal enclosure index
1.3.6.1.4.1.3582.4.1.5.2.1.4ColumnslotCountread-onlyoptionalNumber of slots
1.3.6.1.4.1.3582.4.1.5.2.1.5ColumnpsCountread-onlyoptionalNumber of power supplies
1.3.6.1.4.1.3582.4.1.5.2.1.6ColumnfanCountread-onlyoptionalNumber of fans
1.3.6.1.4.1.3582.4.1.5.2.1.7ColumntempSensorCountread-onlyoptionalNumber of temperature sensors
1.3.6.1.4.1.3582.4.1.5.2.1.8ColumnalarmCountread-onlyoptionalNumber of alarms
1.3.6.1.4.1.3582.4.1.5.2.1.9ColumnsimCountread-onlyoptionalNumber of SIM modules
1.3.6.1.4.1.3582.4.1.5.2.1.10ColumnisFaultread-onlyoptionalEnclosure has entered a FAULT state or not. Values: false(0),true(1)
1.3.6.1.4.1.3582.4.1.5.2.1.11ColumnpdCountread-onlyoptionalNumber of physical drives present
1.3.6.1.4.1.3582.4.1.5.2.1.12ColumnpdIdsread-onlyoptionalPhysical drive deviceIds space separated.
1.3.6.1.4.1.3582.4.1.5.2.1.13ColumnadapterID-ETread-onlyoptionalAdapter ID.
1.3.6.1.4.1.3582.4.1.5.2.1.14ColumnpdCountSpinup60read-onlyoptionalNumber of drives that can spun up in 60 sec.
1.3.6.1.4.1.3582.4.1.5.2.1.15ColumnenclosureTyperead-onlyoptionalInformation about type of enclosure : 0= UNKNOWN ,1= SAFTE ,2=SES ,3= SGPIO ,4=OEM specific
1.3.6.1.4.1.3582.4.1.5.2.1.16ColumnenclFirmwareVersionread-onlyoptionalInformation about enclosure FW Version
1.3.6.1.4.1.3582.4.1.5.2.1.17ColumnenclSerialNumberread-onlyoptionalEnclosure Serial Number
1.3.6.1.4.1.3582.4.1.5.2.1.18ColumnvendorIDread-onlyoptionalEnclosure Vendor ID
1.3.6.1.4.1.3582.4.1.5.2.1.19ColumnproductIDread-onlyoptionalEnclosure Product ID
1.3.6.1.4.1.3582.4.1.5.2.1.20ColumneSMSerialNumberread-onlyoptionalIBM Enclosure ESM Serial Number
1.3.6.1.4.1.3582.4.1.5.2.1.21ColumneSMFRUread-onlyoptionalInformation about IBM Enclosure ESM FRU
1.3.6.1.4.1.3582.4.1.5.2.1.22ColumnenclosureZoningModeread-onlyoptionalEnclosure IBM Zoning Mode
1.3.6.1.4.1.3582.4.1.5.2.1.23ColumneSMFRUPartInforead-onlyoptionalInformation about IBM Enclosure ESM FRU Part
1.3.6.1.4.1.3582.4.1.5.3TableenclosureFanTablenot-accessibleoptionalA List of fan Entries containing Information/Properties about the enclosureFan.
1.3.6.1.4.1.3582.4.1.5.3.1RowenclosureFanEntrynot-accessiblemandatoryAn Entry in the enclosureFan table.
1.3.6.1.4.1.3582.4.1.5.3.1.1ColumnfanIDread-onlyoptionalID for this EnclosureFan.(Unique)
1.3.6.1.4.1.3582.4.1.5.3.1.2ColumnenclosureIdread-onlyoptionalEnclosure ID where the fan is attached
1.3.6.1.4.1.3582.4.1.5.3.1.3ColumnfanStatusread-onlyoptionalstatus of the fan
1.3.6.1.4.1.3582.4.1.5.4TableenclosureSlotTablenot-accessibleoptionalA List of slot Entries containing Information/Properties about the enclosure slots.
1.3.6.1.4.1.3582.4.1.5.4.1RowenclosureSlotEntrynot-accessiblemandatoryAn Entry in the enclosureSlot table.
1.3.6.1.4.1.3582.4.1.5.4.1.1ColumnslotIDread-onlyoptionalID for this slot.(Unique)
1.3.6.1.4.1.3582.4.1.5.4.1.2ColumnenclosureId-ESTread-onlyoptionalenclosure ID
1.3.6.1.4.1.3582.4.1.5.4.1.3ColumnslotStatusread-onlyoptionalstatus of the device
1.3.6.1.4.1.3582.4.1.5.5TableenclosurePowerSupplyTablenot-accessibleoptionalA List of powerSupply Entries containing Information/Properties about the enclosure powerSupply
1.3.6.1.4.1.3582.4.1.5.5.1RowenclosurePowerSupplyEntrynot-accessiblemandatoryAn Entry in the powerSupply table.
1.3.6.1.4.1.3582.4.1.5.5.1.1ColumnpowerSupplyIDread-onlyoptionalID for this powerSupply.(Unique)
1.3.6.1.4.1.3582.4.1.5.5.1.2ColumnenclosureId-EPSTread-onlyoptionalEnclosure id for the powerSupply
1.3.6.1.4.1.3582.4.1.5.5.1.3ColumnpowerSupplyStatusread-onlyoptionalStatus of the power Supply
1.3.6.1.4.1.3582.4.1.5.6TableenclosureTempSensorTablenot-accessibleoptionalA List of TempSensor Entries containing Information/Properties about the enclosure TempSensor
1.3.6.1.4.1.3582.4.1.5.6.1RowenclosureTempSensorEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.4.1.5.6.1.1ColumntempSensorIDread-onlyoptionalID for this TempSensor.(Unique)
1.3.6.1.4.1.3582.4.1.5.6.1.2ColumnenclosureId-ETSTread-onlyoptionalEnclosure id for this TempSensor
1.3.6.1.4.1.3582.4.1.5.6.1.3ColumntempSensorStatusread-onlyoptionalStatus of the Temparature Sensor
1.3.6.1.4.1.3582.4.1.5.6.1.4ColumnenclosureTemperatureread-onlyoptionalCurrent temperature in degree Centigrade
1.3.6.1.4.1.3582.4.1.5.7TableenclosureAlarmTablenot-accessibleoptionalA List of Alarm Entries containing Information/Properties about enclosure Alarms
1.3.6.1.4.1.3582.4.1.5.7.1RowenclosureAlarmEntrynot-accessiblemandatoryAn Entry in the enclosureAlarm table.
1.3.6.1.4.1.3582.4.1.5.7.1.1ColumnalarmIDread-onlyoptionalID for this Alarm.(Unique)
1.3.6.1.4.1.3582.4.1.5.7.1.2ColumnenclosureId-EATread-onlyoptionalEnclosure id where the Alarm is attached
1.3.6.1.4.1.3582.4.1.5.7.1.3ColumnalarmStatusread-onlyoptionalStatus of the alarm
1.3.6.1.4.1.3582.4.1.5.8TableenclosureSIMTablenot-accessibleoptionalA List of SIM Entries containing Information/Properties about enclosure SIMs
1.3.6.1.4.1.3582.4.1.5.8.1RowenclosureSIMEntrynot-accessiblemandatoryAn Entry in the enclosureSIM table.
1.3.6.1.4.1.3582.4.1.5.8.1.1ColumnsimIDread-onlyoptionalID for this SIM.(Unique)
1.3.6.1.4.1.3582.4.1.5.8.1.2ColumnenclosureId-ESITread-onlyoptionalInclosure ID where the SIM is attached
1.3.6.1.4.1.3582.4.1.5.8.1.3ColumnsimStatusread-onlyoptionalStatus of the SIM
1.3.6.1.4.1.3582.4.1.6NodeadapterTraps
1.3.6.1.4.1.3582.4.1.6.1001ScalaratAdpNumberread-onlyoptionalAdapter ID for which Trap is generated.
1.3.6.1.4.1.3582.4.1.6.1002ScalaratAlarmStateread-onlyoptionalAlarm disabled/enabled. Values: disabled(0),enabled(1)
1.3.6.1.4.1.3582.4.1.6.1003ScalaratRateread-onlyoptionalBGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate
1.3.6.1.4.1.3582.4.1.6.1004ScalaratFlashImageNameread-onlyoptionalFlash Image Name
1.3.6.1.4.1.3582.4.1.6.1005ScalaratIDread-onlyoptionalID
1.3.6.1.4.1.3582.4.1.6.1006ScalarclustCtrlpropResetread-onlyoptionalResetting controller property
1.3.6.1.4.1.3582.4.1.6.8001NodeadpAlarmStateEnabledAlarm has been enabled by user for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8002NodeadpBGIRateChangedBackground initialization rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.4.1.6.8003NodeadpCacheDiscardedController $1 cache discarded due to memory/battery problems
1.3.6.1.4.1.3582.4.1.6.8004NodeadpCacheRebootCantRecoverUnable to recover cache data due to configuration mismatch for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8005NodeadpCacheRebootRecoverCache data recovered successfully for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8006NodeadpCacheVersionMismatchController cache discarded due to firmware version incompatibility for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8007NodeadpCCRateChangedConsistency Check rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.4.1.6.8008NodeadpFlashBadImageFlash downloaded image corrupted for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8009NodeadpFlashEraseErrorFlash erase error for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8010NodeadpFlashEraseTimeoutFlash timeout during erase for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8011NodeadpFlashGeneralErrorFlash error for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8012NodeadpFlashImageFlashing image: $1 for Adapter $2
1.3.6.1.4.1.3582.4.1.6.8013NodeadpFlashOKFlash of new firmware image(s)complete for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8014NodeadpFlashProgramErrorFlash programming error for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8015NodeadpFlashProgramTimeoutFlash timeout during programming for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8016NodeadpLogClearedEvent log cleared for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8017NodeadpLogWrappedEvent log wrapped for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8018NodeadpPatrolReadCompletePatrol Read complete for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8019NodeadpPatrolReadPausedPatrol Read paused for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8020NodeadpPatrolReadResumedPatrol Read resumed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8021NodeadpPatrolReadStartedPatrol Read started for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8022NodeadpShutdownShutdown command received for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8023NodeadpHibernateHibernate command received for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8024NodeadpCrashFatal error received for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8025NodeadpRRChangedRebuild rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.4.1.6.8026NodeadpPRRateChangedPatrol Read rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.4.1.6.8027NodeadpAlarmStateDisabledAlarm has been disabled by user for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8028NodeadpConfigClearedConfiguration cleared for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8029NodeadpReconRateChangedReconstruction rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.4.1.6.8030NodeadpDefaultFactory defaults restored for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8031NodebbuPresentBattery Present for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8032NodebbuNotPresentBattery Not Present for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8033NodebbuNewBatteryNew Battery Detected for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8034NodebbuReplacedBattery has been replaced for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8035NodebbuTempHighBattery temperature is high for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8036NodebbuVoltageLowBattery voltage low for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8037NodebbuChargingBattery started charging for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8038NodebbuDisChargingBattery is discharging for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8039NodebbuTempNormalBattery temperature is normal for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8040NodebbuReplaceBattery needs replacement, SOH Bad for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8041NodebbuRelearnStartedBattery relearn started for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8042NodebbuRelearnProgressBattery relearn in progress for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8043NodebbuRelearnCompleteBattery relearn completed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8044NodebbuRelearnTimeoutBattery relearn timed out for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8045NodebbuRelearnPendingBattery relearn pending: Battery is under charge for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8046NodebbuRelearnPostponedBattery relearn postponed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8047NodebbuRemovedBattery removed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8048NodebbuCapacityLowCurrent capacity of the battery is below threshold for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8049NodebbuCapacityAboveCurrent capacity of the battery is above threshold for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8050NodebbuFRUChangedBbu FRU for Adapter $1 changed
1.3.6.1.4.1.3582.4.1.6.8051NoderevisionIdentifierChangedRevision Identifier for Adapter $1 changed
1.3.6.1.4.1.3582.4.1.6.8052NodeadpLockKeyCreatedDrive security key created for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8053NodeadpLockKeyBackedupDrive security key backed up for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8054NodeadpLockKeyVerifiedEscrowDrive security key from escrow, verified for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8055NodeadpLockKeyRekeyedDrive security key changed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8056NodeadpLockKeyRekeyFailedDrive security key, re-key operation failed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8057NodeadpLockKeyInvalidDrive security key is invalid for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8058NodeadpLockKeyDestroyedDrive security key destroyed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8059NodeadpEscrowKeyInvalidDrive security key from escrow is invalid for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8060NodeadpLockKeyFailedDrive security key failure, cannot access secured configuration for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8061NodebbuChargeDisabledBattery charging was suspended due to high battery temperature on Adapter $1
1.3.6.1.4.1.3582.4.1.6.8062NodebbuMicrocodeUpdatedBattery NVCache firmware update was successful on Adapter $1
1.3.6.1.4.1.3582.4.1.6.8063NodebbuMicrocodeUpdateFailedBattery NVCache firmware update failed on Adapter $1
1.3.6.1.4.1.3582.4.1.6.8064NodehaNodeJoinPeer controller entered HA Domain at Adapter -$1
1.3.6.1.4.1.3582.4.1.6.8065NodehaNodeBreakPeer controller exited HA Domain at Adapter -$1
1.3.6.1.4.1.3582.4.1.6.8066NodehaPeerIncompatiblePeer controller settings are incompatible
1.3.6.1.4.1.3582.4.1.6.8067NodehaCtrlpropIncompatibleController property mismatch detected with Peer controller
1.3.6.1.4.1.3582.4.1.6.8068NodehaFWVersionMismatchFW version does not match Peer controller
1.3.6.1.4.1.3582.4.1.6.8069NodehaCacheMirrorOnlineCache mirroring is online
1.3.6.1.4.1.3582.4.1.6.8070NodehaCacheMirrorOfflineCache mirroring is offline
1.3.6.1.4.1.3582.4.1.6.8071NodeadpPropChangedController properties changed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8072NodeadpResetNowStartController reset requested by host for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8073NodeadpResetNowDoneController reset requested by host, completed for Adapter $1
1.3.6.1.4.1.3582.4.1.6.8074NodepeerControllerKeyMismatchPeer controller security key mismatch
1.3.6.1.4.1.3582.4.1.6.8075NodepeerControllerKeyMatchPeer controller security key match
1.3.6.1.4.1.3582.4.1.6.8077NodecfgAutoCreatedConfiguration automatically created on Adapter $1
1.3.6.1.4.1.3582.4.1.6.8078NodenvcacheBlockRecoverySkippedBlock recovery is skipped for Cache-vault. Reboot the system to recover the blocks $1
1.3.6.1.4.1.3582.4.1.7NodevdTraps
1.3.6.1.4.1.3582.4.1.7.1101ScalarvdNumberread-onlyoptionalvd Target ID for which Trap is generated.
1.3.6.1.4.1.3582.4.1.7.1102ScalarvdSeqread-onlyoptionalvd Sequence no for which Trap is generated.
1.3.6.1.4.1.3582.4.1.7.1103ScalarvdProgread-onlyoptionalprogress %
1.3.6.1.4.1.3582.4.1.7.1104ScalarvdCachePolicyChangeReasonread-onlyoptionalVD cache policy.
1.3.6.1.4.1.3582.4.1.7.1105ScalarvdNewStateread-onlyoptionalVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
1.3.6.1.4.1.3582.4.1.7.1106ScalarvdOldStateread-onlyoptionalVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
1.3.6.1.4.1.3582.4.1.7.1107ScalarisRemoteread-onlyoptionalHA cluster locale: 0=local, 1=remote (at peer)
1.3.6.1.4.1.3582.4.1.7.1108ScalarvdOldAccessPolicyread-onlyoptionalVirtual Drive access policy. Values are: read/write(0), read-only(2), blocked(3), transport-ready(14), hidden(15)
1.3.6.1.4.1.3582.4.1.7.1109ScalarvdNewAccessPolicyread-onlyoptionalVirtual Drive access policy. Values are: read/write(0), read-only(2), blocked(3), transport-ready(14), hidden(15)
1.3.6.1.4.1.3582.4.1.7.1110ScalarvdOldAutoSnapshotread-onlyoptionalVirtual Drive auto snapshot. Values are: enabled(1), disabled(0)
1.3.6.1.4.1.3582.4.1.7.1111ScalarvdNewAutoSnapshotread-onlyoptionalVirtual Drive auto snapshot. Values are: enabled(1), disabled(0)
1.3.6.1.4.1.3582.4.1.7.1112ScalarvdOldcacheBypassIOSizeread-onlyoptionalVirtual Drive cache bypass IO size. Values are: 64k(0), 128k(1), 256k(2)
1.3.6.1.4.1.3582.4.1.7.1113ScalarvdNewcacheBypassIOSizeread-onlyoptionalVirtual Drive cache bypass IO size. Values are: 64k(0), 128k(1), 256k(2)
1.3.6.1.4.1.3582.4.1.7.1114ScalarvdOldcacheBypassModeread-onlyoptionalVirtual Drive cache bypass mode. Values are: intelligent(0), standard(1), custom_mode_1(2), custom_mode_2(3), custom_mode_3(4), reserved_mode_1(5), reserved_mo…
1.3.6.1.4.1.3582.4.1.7.1115ScalarvdNewcacheBypassModeread-onlyoptionalVirtual Drive cache bypass mode. Values are: intelligent(0), standard(1), custom_mode_1(2), custom_mode_2(3), custom_mode_3(4), reserved_mode_1(5), reserved_mo…
1.3.6.1.4.1.3582.4.1.7.1116ScalarvdOldcurrentCachePolicyread-onlyoptionalVirtual Drive current cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(3…
1.3.6.1.4.1.3582.4.1.7.1117ScalarvdNewcurrentCachePolicyread-onlyoptionalVirtual Drive current cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(3…
1.3.6.1.4.1.3582.4.1.7.1118ScalarvdOldcurrentPSPolicyread-onlyoptionalVirtual Drive current powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
1.3.6.1.4.1.3582.4.1.7.1119ScalarvdNewcurrentPSPolicyread-onlyoptionalVirtual Drive current powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
1.3.6.1.4.1.3582.4.1.7.1120ScalarvdOlddefaultCachePolicyread-onlyoptionalVirtual Drive default cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(3…
1.3.6.1.4.1.3582.4.1.7.1121ScalarvdNewdefaultCachePolicyread-onlyoptionalVirtual Drive default cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(3…
1.3.6.1.4.1.3582.4.1.7.1122ScalarvdOlddefaultPSPolicyread-onlyoptionalVirtual Drive default powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
1.3.6.1.4.1.3582.4.1.7.1123ScalarvdNewdefaultPSPolicyread-onlyoptionalVirtual Drive default powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
1.3.6.1.4.1.3582.4.1.7.1124ScalarvdOlddisableAutoDeleteOldestPITread-onlyoptionalVirtual drive disable auto delete oldest pit. Values are: enabled(1), disabled(0)
1.3.6.1.4.1.3582.4.1.7.1125ScalarvdNewdisableAutoDeleteOldestPITread-onlyoptionalVirtual Drive disable auto delete oldest pit. Values are: enabled(1), disabled(0)
1.3.6.1.4.1.3582.4.1.7.1126ScalarvdOlddiskCachePolicyread-onlyoptionalVirtual Drive disk cache policy. Values are: unchanged(0), enabled(1), disabled(2)
1.3.6.1.4.1.3582.4.1.7.1127ScalarvdNewdiskCachePolicyread-onlyoptionalVirtual Drive disk cache policy. Values are: unchanged(0), enabled(1), disabled(2)
1.3.6.1.4.1.3582.4.1.7.1128ScalarvdOldemulationTyperead-onlyoptionalVirtual Drive emulation type. Values are: default(0), disabled(1)
1.3.6.1.4.1.3582.4.1.7.1129ScalarvdNewemulationTyperead-onlyoptionalVirtual Drive emulation type. Values are: default(0), disabled(1)
1.3.6.1.4.1.3582.4.1.7.1130ScalarvdOldenabledAtomicityTyperead-onlyoptionalVirtual Drive enabled automicity type. Values are: disabled(0), write-all(1), write-t10(2)
1.3.6.1.4.1.3582.4.1.7.1131ScalarvdNewenabledAtomicityTyperead-onlyoptionalVirtual Drive enabled automicity type. Values are: disabled(0), write-all(1), write-t10(2)
1.3.6.1.4.1.3582.4.1.7.1132ScalarvdOldexclusiveAccessread-onlyoptionalVirtual Drive exclusive access. Values are: true(1), false(0)
1.3.6.1.4.1.3582.4.1.7.1133ScalarvdNewexclusiveAccessread-onlyoptionalVirtual Drive exclusive access. Values are: true(1), false(0)
1.3.6.1.4.1.3582.4.1.7.1134ScalarvdOldforceEmulationread-onlyoptionalVirtual Drive force emulation. Values are: set(1), not-set(0)
1.3.6.1.4.1.3582.4.1.7.1135ScalarvdNewforceEmulationread-onlyoptionalVirtual Drive force emulation. Values are: set(1), not-set(0)
1.3.6.1.4.1.3582.4.1.7.1136ScalarvdOldnameread-onlyoptionalVirtual Drive name
1.3.6.1.4.1.3582.4.1.7.1137ScalarvdNewnameread-onlyoptionalVirtual Drive name
1.3.6.1.4.1.3582.4.1.7.1138ScalarvdOldnoBGIread-onlyoptionalVirtual Drive set no BGI. Values are: 1(disabled), 0 (enabled)
1.3.6.1.4.1.3582.4.1.7.1139ScalarvdNewnoBGIread-onlyoptionalVirtual Drive set no BGI. Values are: 1(disabled), 0 (enabled)
1.3.6.1.4.1.3582.4.1.7.1140ScalarvdOldscsiUnmapEnabledread-onlyoptionalVirtual Drive SCSI unmap enabled. Values are: 0(disabled), 1(enabled)
1.3.6.1.4.1.3582.4.1.7.1141ScalarvdNewscsiUnmapEnabledread-onlyoptionalVirtual Drive SCSI unmap enabled. Values are: 0(disabled), 1(enabled)
1.3.6.1.4.1.3582.4.1.7.1142ScalarvdOldSSCWriteBuferModeread-onlyoptionalVirtual Drive SSC write buffer mode. Values are: 0(disabled), 1(enabled)
1.3.6.1.4.1.3582.4.1.7.1143ScalarvdNewSSCWriteBuferModeread-onlyoptionalVirtual Drive SSC write buffer mode. Values are: 0(disabled), 1(enabled)
1.3.6.1.4.1.3582.4.1.7.8101NodevdtBGIAbortedBGI aborted on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8102NodevdtBGICompletedBGI completed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8103NodevdtBGIDoneWRBGI completed with uncorrectable errors on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8104NodevdtBGIFailedBGI failed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8105NodevdtBGIStartedBGI started on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8107NodevdtCCStartedCC started on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8108NodevdtCCCompletedCC completed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8109NodevdtCCFailedCC failed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8110NodevdtCCAbortedCC aborted on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8111NodevdtCCCompCorCC completed with correction on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8112NodevdtInitAbortedInitialization aborted on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8113NodevdtInitFailedInitialization failed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8114NodevdtInitCompletedInitialization completed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8115NodevdtInitFastStartedFast Initialization started on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8116NodevdtInitFullStartedFull Initialization started on Adapter-$1 VD Target-$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8117NodevdtReconStartedReconstruction started on Adapter-$1 VD Target-$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8118NodevdtReconCompletedReconstruction completed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8119NodevdtReconResumedReconstruction resumed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8120NodevdtReconStoppedReconstruction stopped on Adapter-$1 VD Target-$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8121NodevdtStateChangeVD state changed on Adapter -$1 VD Target -$2 from $3 to $4
1.3.6.1.4.1.3582.4.1.7.8122NodevdtCreatedA new VD created on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8123NodevdtDeletedA VD deleted on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8124NodevdtSecuredVD is now secured. Adapter -$1 VD Targt -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8125NodevdtPartiallySecuredVD is partially secured. Adapter -$1 VD Targt -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8126NodevdtBbmLogClearedVD bad block table cleared on Adapter -$1 VD Targt -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8127NodevdtERASEAbortedLD Erase aborted on aborted on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8128NodevdtERASECompletedLD Erase completed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8129NodevdtERASEFailedLD Erase failed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8130NodevdtERASEStartedLD Erase started on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8131NodevdtSSCDISASSOCIATEStartedCacheCade(TM) disassociate started on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8132NodevdtSSCDISASSOCIATECompletedCacheCade(TM) disassociate completed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8133NodevdtSSCDISASSOCIATEFailedCacheCade(TM) disassociate failed on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8134NodevdtSSCDISASSOCIATEAbortedCacheCade(TM) disassociate aborted by user on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8135NodevdtACCESSBLOCKEDSSCOFFLINEAccess blocked as cached data in CacheCade(TM) is unavailable on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8136NodehaLDIsRemotePeer controller now manages LD on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8137NodehaLDIsLocalLocal controller now manages VD on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8138NodehaLDTargetIDConflictTarget ID conflict detected. VD on Adapter -$1 VD Target -$2 Remote VD -$3 access is restricted from Peer controller
1.3.6.1.4.1.3582.4.1.7.8139NodehaLDAccessSharedShared access set for VD on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8140NodehaLDAccessExclusiveExclusive access set for VD on Adapter -$1 VD Target -$2 Remote VD -$3
1.3.6.1.4.1.3582.4.1.7.8141NodehaLDIncompatibleAdapter -$1 VD Target -$2 Remote VD -$3 is incompatible in the HA domain
1.3.6.1.4.1.3582.4.1.7.8142NodevdAccessBlockedPeerUnavailableCached data from peer controller is unavailable. LD on Adapter -$1 VD Target -$2 Remote VD -$3 access policy is set to Blocked
1.3.6.1.4.1.3582.4.1.7.8143NodehaLDCompatibleAdapter -$1 VD Target -$2 Remote VD -$3 is compatible in the HA domain
1.3.6.1.4.1.3582.4.1.7.8144NodevdPropChangedAdapter -$1 VD Target -$2 Properties changed. Access policy to $3, currentCachePolicy to $4, currentPSPolicy to $5, defaultCachePolicy to $6, defaultPSPolicy t…
1.3.6.1.4.1.3582.4.1.8NodepdTraps
1.3.6.1.4.1.3582.4.1.8.1201ScalarpdIDread-onlyoptionalDevice ID for which Trap is generated.
1.3.6.1.4.1.3582.4.1.8.1202ScalarpdEncIndexread-onlyoptionalEnclosure index(0 means not within an enclosure) for which Trap is generated.
1.3.6.1.4.1.3582.4.1.8.1203ScalarpdSlotNoread-onlyoptionalSlot no for the enclosure
1.3.6.1.4.1.3582.4.1.8.1204ScalarpdNewStateread-onlyoptionalPhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
1.3.6.1.4.1.3582.4.1.8.1205ScalarpdOldStateread-onlyoptionalPhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
1.3.6.1.4.1.3582.4.1.8.1206ScalarpdEnclDeviceIdread-onlyoptionalEnclosure Device ID for which Trap is generated.
1.3.6.1.4.1.3582.4.1.8.1207ScalarpdSASAddread-onlyoptionalDevice SAS addresses. Comma separeted for multiple address.
1.3.6.1.4.1.3582.4.1.8.1208ScalarpdPathread-onlyoptionalPD path.
1.3.6.1.4.1.3582.4.1.8.1209ScalarpdFRUread-onlyoptionalPD FRU for which trap is generated.
1.3.6.1.4.1.3582.4.1.8.1210ScalarpdNewPowerStateread-onlyoptionalNew Power Status Of the Device.Values are device is active(0),device is stopped(1),device is transitioning between power states(255)
1.3.6.1.4.1.3582.4.1.8.8201NodepdtClearAbortedPhysical Drive Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8202NodepdtClearFailedPhysical Drive Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8203NodepdtClearStartedPhysical Drive Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8204NodepdtClearCompletedPhysical Drive Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8205NodepdtErrorError occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8206NodepdtFormatStartPhysical Drive format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8207NodepdtFormatCompletedPhysical Drive format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8208NodepdtInsertedPD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8209NodepdtRblAbortedRebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8210NodepdtRblCompletedRebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8211NodepdtRblFailedBSRebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8212NodepdtRblFailedBTRebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8213NodepdtRblStartRebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8214NodepdtRblResumedRebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8215NodepdtRblStartARebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8216NodepdtRemovedPhysical Drive removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8217NodepdtStateChangePD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6
1.3.6.1.4.1.3582.4.1.8.8218NodepdtRedundantPathBrokenRedundant Path Broken For Physical Drive on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6
1.3.6.1.4.1.3582.4.1.8.8219NodepdtRedundantPathRestoredRedundant Path Restored For Physical Drive on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6
1.3.6.1.4.1.3582.4.1.8.8220NodepdtRedundantEnclModuleInsertedRedundant Encl Modul Inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 pdpath -$7
1.3.6.1.4.1.3582.4.1.8.8221NodepdtRedundantEnclModuleRemovedRedundant Encl Modul Removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 pdpath -$7
1.3.6.1.4.1.3582.4.1.8.8222NodepdtFRUFRU changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 -FRU $6
1.3.6.1.4.1.3582.4.1.8.8223NodepdtSecuredPD security activated on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8224NodepdtUnsecuredPD security disabled on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8225NodepdtReprovisionedPD is reprovisioned on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8226NodepdtLockKeyRekeyedPD security key changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8227NodepdtSecurityFailureSecurity subsystem problems detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8228NodepdtPowerStateChangePower State Change on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 NewPowerState -$5
1.3.6.1.4.1.3582.4.1.8.8229NodepdtNotSupportedPD Not Supported on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8230NodepdtNotCertifiedPD Not Certified on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8231NodepdtERASEAbortedPD Erase aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8232NodepdtERASECompletedPD Erase completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8233NodepdtERASEStartedPD Erase started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8234NodepdtERASEFailedPD Erase Failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8235NodehaPDIsRemotePeer controller now manages PD on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8236NodehaPDIsLocalLocal controller now manages PD on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.4.1.8.8237NodepdtLOCATEStartLocate LED started on PD Adapter -$1 PD -$2
1.3.6.1.4.1.3582.4.1.8.8238NodepdtLOCATEStopLocate LED stopped on PD Adapter -$1 PD -$2
1.3.6.1.4.1.3582.4.1.9NodeenclTraps
1.3.6.1.4.1.3582.4.1.9.1301ScalaratPortread-onlyoptionalProt no.
1.3.6.1.4.1.3582.4.1.9.1302ScalaronPHYread-onlyoptionalPHY no
1.3.6.1.4.1.3582.4.1.9.8330NodewidePortLinkLostLink lost on SAS wide port on Adapter -$1 port -$2 PHY -$3
1.3.6.1.4.1.3582.4.1.9.8331NodewidePortLinkRestoredLink Restored on SAS wide port on Adapter -$1 port -$2 PHY -$3
1.3.6.1.4.1.3582.4.1.10NodepciTraps
1.3.6.1.4.1.3582.4.1.10.1501ScalarpciVendorIdread-onlyoptionalPCI VendorID
1.3.6.1.4.1.3582.4.1.10.1502ScalarpciDeviceIdread-onlyoptionalPCI Device ID
1.3.6.1.4.1.3582.4.1.10.1503ScalarpciSubVendorIdread-onlyoptionalPCI SubVendorID
1.3.6.1.4.1.3582.4.1.10.1504ScalarpciSubDeviceIdread-onlyoptionalPCI SubDeviceID
1.3.6.1.4.1.3582.4.1.10.8501NodehaHwIncompatiblePeer Controller hardware is incompatible
1.3.6.1.4.1.3582.4.1.11NodecopyrightInfo
1.3.6.1.4.1.3582.4.1.11.1Scalarcopyrightread-onlymandatoryLSI Corporation