MIB Viewer

LSI-megaRAID-SAS-IR-MIB

472 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMICounter enterprises Gauge
RFC1213-MIBDisplayString PhysAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.3582Nodelsi
1.3.6.1.4.1.3582.5NodelsiStorageComponents
1.3.6.1.4.1.3582.5.1NodelsiRAIDServer
1.3.6.1.4.1.3582.5.1.1ScalarhostNameread-onlymandatoryName of the host system.
1.3.6.1.4.1.3582.5.1.2ScalarhostOSInforead-onlymandatoryOperating System description where SNMP agent is running.
1.3.6.1.4.1.3582.5.1.3NodeversionInfo
1.3.6.1.4.1.3582.5.1.3.1ScalarmibVersionread-onlymandatoryThe MIB version no. (xx.yy.zz)
1.3.6.1.4.1.3582.5.1.3.2ScalaragentModuleNameread-onlymandatoryThe agent module name
1.3.6.1.4.1.3582.5.1.3.3ScalaragentModuleVersionread-onlymandatoryThe module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information).
1.3.6.1.4.1.3582.5.1.3.4ScalarreleaseDateread-onlymandatoryModule Release Date (DD/MM/YYYY)
1.3.6.1.4.1.3582.5.1.4NodemegaRAID-SAS-IR
1.3.6.1.4.1.3582.5.1.4.1Nodeadapter
1.3.6.1.4.1.3582.5.1.4.1.1NodeadapterDetails
1.3.6.1.4.1.3582.5.1.4.1.1.1ScalaradpNumberread-onlymandatoryThe total no of SAS adapters present.
1.3.6.1.4.1.3582.5.1.4.1.1.2TableadapterPropertiesTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1RowadapterPropertiesEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.1ColumnadapterIDread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.2ColumnrebuildRateread-onlyoptionalRebuild rate on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.3ColumnreconstructionRateread-onlyoptionalReconstruction rate on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.4ColumnalarmStateread-onlyoptionalAlarm is enabled(1) or disabled(0) on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.5ColumncacheFlushIntervalread-onlyoptionalCache flush interval in seconds for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.6ColumnclusterStateread-onlyoptionalCluster is enabled(1) or disabled(0) on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.7ColumnpredFailPollIntervalread-onlyoptionalNumber of seconds between predictive fail polls on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.8ColumnintThrottleCountread-onlyoptionalInterrupt throttle active count on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.9ColumnintThrottleTimeUsread-onlyoptionalInterrupt throttle completion hold time on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.10ColumnpatrolReadRateread-onlyoptionalPatrol Read Rate for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.11ColumnbgiRateread-onlyoptionalBackground initialization rate for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.12ColumnccRateread-onlyoptionalConsistency Check rate on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.13ColumnspinupDelayread-onlyoptionalNumber of seconds to delay among spinup groups for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.14ColumnspinupDriveCountread-onlyoptionalMaximum number of drives to spin up at one time for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.15ColumncoercionModeread-onlyoptionalDrive capacity coercion mode. 0->None; 1->128MB; 2->1GB; 3->Adaptive Coercion.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.16ColumndisableAutoRebuildread-onlyoptionalauto-rebuild and hot-spare commissioning status. 1->Disable , 0->Enable
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.17ColumndisableBatteryWarningread-onlyoptionaldisable/enable warnings for missing battery or missing HW status. 1->Disable , 0->Enable
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.18ColumnmultipathSupportread-onlyoptionalMultipath is supported or not supported on this adapter.Values: not supported(0),supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.19ColumnssdSMARTerEnabledread-onlyoptionalCopyback to SSD on SMART error. Values Enabled(0),Disabled(1)
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.20ColumnsasAddrread-onlyoptionalThis field gives the controller SAS address
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.21ColumnauxilaryPowerPresentread-onlyoptionalPresence of Auxilary Power
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.22ColumnddLifeCurveStatusread-onlyoptionalCheck for throttling
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.23ColumnddSSDLifeLeftread-onlyoptionalPercentage of SSD life left
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.24ColumndDStatusread-onlyoptionalOverall DD status
1.3.6.1.4.1.3582.5.1.4.1.1.3TableadapterInfoTablenot-accessibleoptionalA List of adapter Entries containing Information/Properties about the adapters.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1RowadapterInfoEntrynot-accessiblemandatoryAn Entry in the adapterInfo table.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.1ColumninfAdpIDread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.2ColumnvendorIdread-onlyoptionalPCI Vendor ID for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.3ColumndevIdread-onlyoptionalPCI Device ID for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.4ColumnsubVendorIDread-onlyoptionalPCI Sub-Vendor ID for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.5ColumnsubDevIDread-onlyoptionalPCI Sub-Device ID for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.6ColumnhostInterfaceread-onlyoptionalHost interface information for this adapter. Values are as follows: N/A(0), PCIX(1), PCIE(2), iSCSI(3), SAS_3G(4)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.7ColumnhostInterfacePortCntread-onlyoptionalPort Count on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.8ColumnhostInterfacePortAddrread-onlyoptionalPort address comma delimited
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.9ColumndevInterfaceread-onlyoptionalMultiple device interface support values separated by space.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.10ColumndevInterfacePortCntread-onlyoptionalDevice Port Count on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.11ColumndevInterfacePortAddrread-onlyoptionalDevice Port address comma delimited
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.12ColumnproductNameread-onlyoptionalProduct name e.g. SAS2008 B1.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.13ColumnserialNoread-onlyoptionalController serial number
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.14ColumnfirmwareVersionread-onlyoptionalFirmware version Format->(Firmware Package Version:Version:Date:Time)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.15ColumndriverVersionread-onlyoptionalDriver version Format->(Driver Name:Version)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.16ColumnnvramSizeread-onlyoptionalNVRAM size in KB for this adapter.A value -1 for invalid or undefined size.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.17ColumnmemorySizeread-onlyoptionalMemory size in MB for this adapter.A value -1 for invalid or undefined size.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.18ColumnflashSizeread-onlyoptionalFlash size in MB for this adapter.A value -1 for invalid or undefined size.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.19ColumnvdPresentCountread-onlyoptionalVirtual devices present in this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.20ColumnvdDegradedCountread-onlyoptionalNumber of virtual devices in this adapter that are critical
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.21ColumnvdOfflineCountread-onlyoptionalNumber of virtual devices in this adapter that are offline
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.22ColumnpdPresentCountread-onlyoptionalPhysical devices present in this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.23ColumnpdDiskPresentCountread-onlyoptionalPhysical disk devices present in this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.24ColumnpdDiskPredFailureCountread-onlyoptionalNumber of disk devices in this adapter that are critical
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.25ColumnpdDiskFailedCountread-onlyoptionalNumber of disk devices in this adapter that are failed
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.26ColumnclusterStatusread-onlyoptionalCluster state on this adapter. Values: ACTIVE(1), INACTIVE(0)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.27ColumndevInterfaceTyperead-onlyoptionalType of the interface of the IR adapter. Values: GEN1(0), GEN2(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4TableadapterSupportInfoTablenot-accessibleoptionalA List of Entries containing Properties supported by the Controller.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1RowadapterSupportInfoEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.1ColumnsuAdpIDread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.2ColumnsupportMaxArmsread-onlyoptionalMaximum arms per Logical Drive supported for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.3ColumnsupportMaxSpansread-onlyoptionalMaximum spans per Logical Drive supported for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.4ColumnsupportMaxArraysread-onlyoptionalMaximum number arrays supported this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.5ColumnsupportMaxLDsread-onlyoptionalMaximum number of Logical Drive's supported for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.6ColumnsupportHardwarePresentread-onlyoptionalSupported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4). For multiple hardware support a comma delimited list will appear.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.7ColumnsupportMaxConcurrentCmdsread-onlyoptionalThe maximum parallel commands supported on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.8ColumnsupportMaxSGECountread-onlyoptionalThe maximum Scatter Gather Element count allowed on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.9ColumnsupportMaxRequestSizeread-onlyoptionalThe maximum data transfer size in sectors, on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.10ColumnsupportClusterPermittedread-onlyoptionalClustering support on this Adapter. Values: FALSE(0), TRUE(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.11ColumnsupportMinStripeSizeread-onlymandatoryMinimum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.12ColumnsupportMaxStripeSizeread-onlymandatoryMaximum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.13ColumnsupportSupportsSASread-onlymandatorySAS physical drive support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.14ColumnsupportSupportsSATAread-onlymandatorySATA physical drive support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.15ColumnsupportAllowMixInEnclosureread-onlymandatoryMix InEnclosure support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.16ColumnsupportAllowMixInVDread-onlymandatoryMixInVD support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.17ColumnsupportAllowSataInClusterread-onlymandatorySataInCluster support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.18ColumnallowSSDMixInLDread-onlymandatoryallow SAS/SATA SSD mix within an LD. allow(1), not allow(0)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.19ColumnallowMixSSDHDDInLDread-onlymandatoryallow SSD/HDD mix within an LD.allow(1), not allow(0)
1.3.6.1.4.1.3582.5.1.4.1.1.5TableadpOperationsSupportInfoTablenot-accessibleoptionalA List of Entries containing operations supported by the Controller.
1.3.6.1.4.1.3582.5.1.4.1.1.5.1RowadpOperationsSupportInfoEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.1ColumnopAdpIDread-onlyoptionalAdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.2ColumnrbldRateread-onlyoptionalRebuilding rate change support for this Adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.3ColumnsuCCRateread-onlyoptionalConsistency Check rate change support for this Adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.4ColumnsuBgiRateread-onlyoptionalBackground initialization rate change support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.5ColumnreconRateread-onlyoptionalReconstruction rate change support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.6ColumnpatrolRateread-onlyoptionalPatrol read rate change support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.7ColumnalarmControlread-onlyoptionalAlarm control support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.8ColumnclusterSupportedread-onlyoptionalCluster support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.9Columnbburead-onlyoptionalBBU support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.10ColumnspanningAllowedread-onlyoptionalSpanning support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.11ColumndedicatedHotSparesread-onlyoptionalDedicated HotSpares for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.12ColumnrevertibleHotSparesread-onlyoptionalRevertible HotSpares support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.13ColumnforeignConfigImportread-onlyoptionalSupport foreign config import on this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.14ColumnselfDiagnosticread-onlyoptionalController supports self diagnostic. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.15ColumnallowMixedRedundancyOnArrayread-onlyoptionalAllow different Virtual Disk on the same array to have different redundancy levels Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.16ColumnglobalHotSparesread-onlyoptionalGlobal hot spares are supported. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.17ColumnoceWithNoDriveAdditionread-onlyoptionalOnline Capacity Expansion supported. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.6TabledriveOperationSupportTablenot-accessibleoptionalA List of operations supported by Physical Drive.
1.3.6.1.4.1.3582.5.1.4.1.1.6.1RowdriveOperationSupportEntrynot-accessiblemandatoryAn Entry in the driveOperationSupport table.
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.1ColumndrvAdpIDread-onlymandatoryUnique adapter ID
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.2ColumnforceOnlineread-onlymandatoryPhysical Drive force Online operation support Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.3ColumnforceOfflineread-onlymandatoryPhysical Drive force Offline operation support Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.4ColumnforceRebuildread-onlymandatoryPhysical Drive force Rebuild operation support Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7TablevdOperationSupportTablenot-accessibleoptionalA List operations supported by Virtual Drive
1.3.6.1.4.1.3582.5.1.4.1.1.7.1RowvdOperationSupportEntrynot-accessiblemandatoryAn Entry in the vdOperationSupport Table.
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.1ColumnvdOpAdpIDread-onlymandatoryUnique adapter ID
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.2ColumnreadPolicyread-onlymandatoryRead policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.3ColumnwritePolicyread-onlymandatoryWrite policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.4ColumnioPolicyread-onlymandatoryIO policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.5ColumnaccessPolicyread-onlymandatoryAccess policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.6ColumndiskCachePolicyread-onlymandatoryDisk Cache Policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.2NodebbuInfo
1.3.6.1.4.1.3582.5.1.4.1.2.1ScalarbbuNumberread-onlymandatoryThe present number of rows in the bbuTable.
1.3.6.1.4.1.3582.5.1.4.1.2.2TablebbuTablenot-accessibleoptionalA List of bbu Entries containing Information/Properties about the BBU.
1.3.6.1.4.1.3582.5.1.4.1.2.2.1RowbbuEntrynot-accessiblemandatoryAn Entry in the BBU table.
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.1ColumnbbuIDread-onlyoptionalBBUID for this BBU.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.2ColumnbatteryTyperead-onlyoptionalBBU Type: Values: n/a(0), ibbu(1), bbu(2), zcr_legacy(3), itbbu3(4)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.3ColumnnextLearnTimeread-onlyoptionalTime of next scheduled lean cycle (seconds path 1/1/2000)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.4ColumnabsStateOfChargeread-onlyoptionalPredicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.5ColumnfullChargeCapacityread-onlyoptionalPredicted pack capacity when it is fully charged in mAh
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.6ColumnaverageEmptyTimeread-onlyoptionalOne-minute rolling average of the predicted remaining battery life. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.7ColumncycleCountread-onlyoptionalNumber of charge cycles the battery has experienced. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.8ColumnfirmwareStatusread-onlyoptionalcondition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) …
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.9Columnvoltageread-onlyoptionalAccurate battery terminal voltage in mV, resolution of 1mV
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.10ColumnautoLearnPeriodread-onlyoptionalTime (in seconds) between learn cycles (0 to disable auto learn)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.11ColumnrelStateOfChargeread-onlyoptionalPredicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.12ColumncapacityRemainread-onlyoptionalPredicted charge or energy remaining in the battery in mAh
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.13ColumnrunTimeToEmptyread-onlyoptional(in minutes)Relative gain or loss in remaining life in response to change in power policy. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.14ColumnavgTimeToFullread-onlyoptionalOne-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.15ColumnerrorMarginread-onlyoptionalExpected margin of error (%) in charge calculation (2-100). Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.16Columntemperatureread-onlyoptionalBattery temperature in degree Centigrade
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.17ColumnmfgNameread-onlyoptionalBattery manufacturer's name
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.18ColumndeviceNameread-onlyoptionalBattery name
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.19ColumnserialNumberread-onlyoptionalBattery serialNumber
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.20ColumnchargerStatusread-onlyoptionalBattery charger status. Values: N/A(-1), off(0), complete(1), progress(2)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.21ColumnadpIDread-onlyoptionalThe adapter id where BBU is attached
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.22ColumnremainingCapAlarmread-onlyoptionalRemaining capacity to alarm. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.23ColumnremainingTimeAlarmread-onlyoptionalRemaining time to alarm. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.24Columnbbu-currentread-onlyoptionalCurrent(In mA) being supplied (or accepted) through the terminals of the battery
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.25ColumngasGaugeStatusread-onlyoptionalGas guage status
1.3.6.1.4.1.3582.5.1.4.2Nodedevice
1.3.6.1.4.1.3582.5.1.4.2.1NodephysicalDriveInfo
1.3.6.1.4.1.3582.5.1.4.2.1.1ScalarpdNumberread-onlymandatoryThe present number of rows in the physicalDrive table.
1.3.6.1.4.1.3582.5.1.4.2.1.2TablepdTablenot-accessibleoptionalA List of physicalDrive Entries containing Information/Properties about the drives
1.3.6.1.4.1.3582.5.1.4.2.1.2.1RowpdEntrynot-accessibleoptionalAn Entry in the Device Table.
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.1ColumnpdIndexread-onlyoptionalThe unique ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.2ColumnphysDevIDread-onlyoptionalThe Device ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.3ColumnoemSupportedread-onlyoptionalDrive support by the OEM (OEM-specific checks) Values: notSupported(1), supported(0)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.4ColumnscsiDevTyperead-onlyoptionalType of this Device. Values: disk(0), tape(1), printer(2), processor(3), cdrom(5), scanner(6), optical(7), enclosure(13), dvd(10), unknown(31)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.5ColumnconnectedAdapterPortread-onlyoptionalAdapter port to which the device is connected.
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.6ColumndeviceSpeedread-onlyoptionalMaximum supported speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2),speed_6G(3)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.7ColumnmediaErrCountread-onlyoptionalError count of the device
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.8ColumnotherErrCountread-onlyoptionalother error count of the device
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.9ColumnpredFailCountread-onlyoptionalPredictive fail count of the device
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.10ColumnpdStateread-onlyoptionalFirmware's interpretation of drive state. Values: unconfigured_good(0), unconfigured_bad(1), hot_spare(2), offline(16), failed(17), rebuild(20), online(24),cop…
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.11ColumndisabledForRemovalread-onlyoptionalIf true, drive is ready for removal. Values: false(0), true(1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.12ColumnlinkSpeedread-onlyoptionalNegotiated link speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2), speed_6G(3)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.13ColumnpdSupportFlagsread-onlyoptional1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCS…
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.14ColumnpdSasAddrread-onlyoptionalDevice SAS addresses. Comma separeted for multiple address
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.15ColumnrawSizeread-onlyoptionalSize(MB) before COD and coercion
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.16ColumnnonCoercedSizeread-onlyoptionalSize(MB) after COD is reserved but before coercion
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.17ColumncoercedSizeread-onlyoptionalSize(MB) after COD is reserved and after coercion
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.18ColumnenclDeviceIdread-onlyoptionalEnclosure's device Id (in decimal); if device is not within enclosure value is -1
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.19ColumnenclIndexread-onlyoptionalFirmware internal enclosure index
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.20ColumnslotNumberread-onlyoptionalSlot number of this drive, if this Physical Drive is an enclosure then -1
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.21ColumnpdOperationProgressread-onlyoptional% Progress is %. e.g. Rebuild progress is 10%
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.22ColumnpdAdpIDread-onlyoptionalController id where this Physical Drive is attached
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.23ColumnoperationSupportread-onlyoptionalOnline,Offline,Failed,Bad,Uncofigured good,Unconfigured bad, Spare,Spare,replaceMissing,markMissing,startRebuild,stopRebuild, locate,stopSecureEraseNonSED,FWDo…
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.24ColumnvendorIDread-onlyoptionalVendor ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.25ColumnproductIDread-onlyoptionalProduct ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.26ColumnpdFwversionread-onlyoptionalPhysical drive firmware version
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.27ColumnpdSerialNumberread-onlyoptionalPhysical drive serial number
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.28ColumndiskTyperead-onlyoptionalType of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.29ColumnpartnerDevIdread-onlyoptionalIf drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.30Columnmediatyperead-onlyoptionalMedia Type HDD(0),SSD(1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.31ColumnoemCertifiedread-onlyoptionalIndicates whether device is certified(0) or not(1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.32ColumnpdTemperatureread-onlyoptionalPhysical Drive temperature in Celsius
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.33ColumnpiTyperead-onlyoptionalSAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS …
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.34ColumnuserDataBlockSizeread-onlyoptionalNumber of bytes of user data in LBA
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.35Columncageread-onlyoptionalCurrent Cage that holds the SSD
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.36Columnlocationread-onlyoptionalCurrent location of SSD 0 - Upper, 1 - Lower
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.37Columnwhtemperatureread-onlyoptionalTemperature of each SSD
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.38ColumnflashTyperead-onlyoptionalFlash Type being used (SLC / MLC / EMLC)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.39ColumnlifeCurveStatusread-onlyoptional100 - No throttling being done, 90 - SSD is being throttled
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.40ColumnsSDLifeLeftread-onlyoptionalPercentage of SSD life left
1.3.6.1.4.1.3582.5.1.4.3NodevirtualDevice
1.3.6.1.4.1.3582.5.1.4.3.1NodevdInfo
1.3.6.1.4.1.3582.5.1.4.3.1.1ScalarvdNumberread-onlymandatoryThe present number of rows in the virtualDrive table.
1.3.6.1.4.1.3582.5.1.4.3.1.2TablevdTablenot-accessibleoptionalA List of Virtual Drive Entries containing Information/Properties about the virtualDrive.
1.3.6.1.4.1.3582.5.1.4.3.1.2.1RowvdEntrynot-accessibleoptionalAn Entry in the virtualDrive Table.
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.1ColumnvirtualDevIDread-onlyoptionalThe unique Virtual Drive ID
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.2Columnsizeread-onlyoptionalTotal size in MB of the drive
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.3ColumnclusterOwnerDeviceIdread-onlyoptionalVirtual Drive owner's device Id
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.4ColumntargetIdread-onlyoptionalVirtual Drive target id (i.e. 0 to 63)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.5Columnstateread-onlyoptionalVirtual Drive state. Values: offline(0), partially_degraded(1), degraded(2), optimal(3)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.6Columnnameread-onlyoptionalVirtual Drive name
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.7ColumndefaultCachePolicyread-onlyoptionalDefault cache policy settings. Values: direct_io(0), cached_io(1)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.8ColumnvdAccessPolicyread-onlyoptionalAccess policy settings. Values: access_rw(0), access_read_only(2), access_blocked(3)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.9ColumnvdDiskCachePolicyread-writeoptionalPhysical disk cache policy. Values: enable(1), disable(2)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.10ColumnbgiStateread-onlyoptionalBGI state on this VD. Values disable(1), enable(0)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.11Columnprlread-onlyoptionalPrimay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E/10), 21(RAID-5E), 31(Concatenat…
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.12ColumnrLQread-onlyoptionalRaid level qualifier
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.13ColumnsRLread-onlyoptionalSecondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned), -1(Not Supported for IR2)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.14ColumnstripeSizeread-onlyoptionalStripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.15ColumnnumDrivesread-onlyoptionalNumber of drivers per span
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.16ColumnspanDepthread-onlyoptionalNumber of spans. If only one array then it is considered as 1 span
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.17ColumninitStateread-onlyoptional0=no init, 1=quick init, 2=full init
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.18ColumncurrentCachePolicyread-onlyoptionalDefault cache policy settings. Values: direct_io(0), cached_io(1)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.19ColumnoperationProgressread-onlyoptionalProgress % for operation x/ No operation in progress
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.20ColumnvdAdpIDread-onlyoptionalController id where this vd is present
1.3.6.1.4.1.3582.5.1.4.3.2NodevdSpanInfo
1.3.6.1.4.1.3582.5.1.4.3.2.1ScalarvdSpanNumberread-onlymandatoryThe present number of rows in the virtualDrive table.
1.3.6.1.4.1.3582.5.1.4.3.2.2TablevdSpanTablenot-accessibleoptionalA List of span Entries containing Information/Properties vd span.
1.3.6.1.4.1.3582.5.1.4.3.2.2.1RowvdSpanEntrynot-accessibleoptionalAn Entry in the vdSpan Table.
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.1ColumnspanIDread-onlyoptionalThe unique Span ID
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.2ColumnvDevIDread-onlyoptionalThe Virtual Device ID
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.3ColumnstartBlockread-onlyoptionalSpan physical disk starting block
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.4ColumnnumBlocksread-onlyoptionalSpan physical disk block count
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.5ColumnvdsArrayRefread-onlyoptionalArray reference (index)
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.6ColumnspAdpIdread-onlyoptionalAdapter where the span will be found
1.3.6.1.4.1.3582.5.1.4.3.3NodearrayInfo
1.3.6.1.4.1.3582.5.1.4.3.3.1ScalararrayNumberread-onlymandatoryThe present number of rows in the array table.
1.3.6.1.4.1.3582.5.1.4.3.3.2TablearrayTablenot-accessibleoptionalA List of array Entries containing Information/Properties about the arrays.
1.3.6.1.4.1.3582.5.1.4.3.3.2.1RowarrayEntrynot-accessibleoptionalAn Entry in the array Table.
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.1ColumnarrayIDread-onlyoptionalThe unique array ID
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.2ColumnarrSizeread-onlyoptionalSize in MB
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.3ColumnarrNumDrivesread-onlyoptionalNumber of drives for this array
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.4ColumnarrayRefread-onlyoptionalTag for the array
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.5ColumnpdListread-onlyoptionalSpace separated pd identification. e.g. {devID devID devID} etc
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.6ColumnarrAdpIdread-onlyoptionalAdapter where the array will be found
1.3.6.1.4.1.3582.5.1.4.3.4NodespareInfo
1.3.6.1.4.1.3582.5.1.4.3.4.1ScalarspareDevNumberread-onlymandatoryThe present number of rows in the sparepool table.
1.3.6.1.4.1.3582.5.1.4.3.4.2TablespareTablenot-accessibleoptionalA List of sparepool Entries containing Information/Properties about the spare drive
1.3.6.1.4.1.3582.5.1.4.3.4.2.1RowspareEntrynot-accessibleoptionalAn Entry in the sparepool Table.
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.1ColumnspareIDread-onlyoptionalThe unique Index
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.2ColumndeviceIdentificationread-onlyoptionalThe Device ID
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.3ColumnspareTyperead-onlyoptionalSpare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable.
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.4ColumnarrayCountread-onlyoptionalThe number of arrays to which the PD can be dedicated
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.5ColumnarrRefread-onlyoptionalComma separated array ids. e.g. 2,4,5 etc
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.6ColumnsprAdpIdread-onlyoptionalAdapter where the spare will be found
1.3.6.1.4.1.3582.5.1.4.4Nodeenclosure
1.3.6.1.4.1.3582.5.1.4.4.1NodeenclosureInfo
1.3.6.1.4.1.3582.5.1.4.4.1.1ScalarenclosureNumberread-onlymandatoryThe present number of rows in the enclosure table.
1.3.6.1.4.1.3582.5.1.4.4.1.2TableenclosureTablenot-accessibleoptionalA List of enclosure Entries containing Information/Properties about the enclosures in the system.
1.3.6.1.4.1.3582.5.1.4.4.1.2.1RowenclosureEntrynot-accessiblemandatoryAn Entry in the enclosure table.
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.1ColumnenclosureIDread-onlyoptionalEnclosureID for this enclosure.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.2ColumndeviceIdread-onlyoptionalEnclosure device Id.
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.3ColumnenclosureIndexread-onlyoptionalFirmware internal enclosure index
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.4ColumnslotCountread-onlyoptionalNumber of slots
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.5ColumnpsCountread-onlyoptionalNumber of power supplies
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.6ColumnfanCountread-onlyoptionalNumber of fans
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.7ColumntempSensorCountread-onlyoptionalNumber of temperature sensors
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.8ColumnalarmCountread-onlyoptionalNumber of alarms
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.9ColumnsimCountread-onlyoptionalNumber of SIM modules
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.10ColumnisFaultread-onlyoptionalEnclosure has entered a FAULT state or not. Values: false(0), true(1)
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.11ColumnpdCountread-onlyoptionalNumber of physical drives present
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.12ColumnpdIdsread-onlyoptionalPhysical drive deviceId's comma separated.
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.13ColumnencAdpIDread-onlyoptionalAdapter ID where this enclosure is connected
1.3.6.1.4.1.3582.5.1.4.4.2NodeenclosureFanInfo
1.3.6.1.4.1.3582.5.1.4.4.2.1ScalarenclosureFanNumberread-onlymandatoryThe present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.2.2TableenclosureFanTablenot-accessibleoptionalA List of fan Entries containing Information/Properties about the enclosureFan.
1.3.6.1.4.1.3582.5.1.4.4.2.2.1RowenclosureFanEntrynot-accessiblemandatoryAn Entry in the enclosureFan table.
1.3.6.1.4.1.3582.5.1.4.4.2.2.1.1ColumnfanIDread-onlyoptionalID for this enclosureFan.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.2.2.1.2ColumnenclosureIdread-onlyoptionalEnclosure ID where the fan is attached
1.3.6.1.4.1.3582.5.1.4.4.2.2.1.3ColumnfanStatusread-onlyoptionalstatus of the device
1.3.6.1.4.1.3582.5.1.4.4.3NodeenclosureSlotInfo
1.3.6.1.4.1.3582.5.1.4.4.3.1ScalarenclosureSlotNumread-onlymandatoryThe present number of rows in the enclosure slot table.
1.3.6.1.4.1.3582.5.1.4.4.3.2TableenclosureSlotTablenot-accessibleoptionalA List of slot Entries containing Information/Properties about the enclosure slots.
1.3.6.1.4.1.3582.5.1.4.4.3.2.1RowenclosureSlotEntrynot-accessiblemandatoryAn Entry in the enclosureSlot table.
1.3.6.1.4.1.3582.5.1.4.4.3.2.1.1ColumnslotIDread-onlyoptionalID for this slot.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.3.2.1.2ColumnsltEncIdread-onlyoptionalEnclosure ID where the slot
1.3.6.1.4.1.3582.5.1.4.4.3.2.1.3ColumnslotStatusread-onlyoptionalstatus of the device. Values: status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), sta…
1.3.6.1.4.1.3582.5.1.4.4.4NodeenclosurePSInfo
1.3.6.1.4.1.3582.5.1.4.4.4.1ScalarenclosurePSNumberread-onlymandatoryThe present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.4.2TableenclosurePSTablenot-accessibleoptionalA List of powerSupply Entries containing Information/Properties about the enclosure powerSupply
1.3.6.1.4.1.3582.5.1.4.4.4.2.1RowenclosurePSEntrynot-accessiblemandatoryAn Entry in the powerSupply table.
1.3.6.1.4.1.3582.5.1.4.4.4.2.1.1ColumnpowerSupplyIDread-onlyoptionalID for this powerSupply.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.4.2.1.2ColumnpsEnclosureIdread-onlyoptionalEnclosure id for the powerSupply
1.3.6.1.4.1.3582.5.1.4.4.4.2.1.3ColumnpowerSupplyStatusread-onlyoptionalstatus of the power Supply
1.3.6.1.4.1.3582.5.1.4.4.5NodeenclosureTSInfo
1.3.6.1.4.1.3582.5.1.4.4.5.1ScalarenclosureTSNumberread-onlymandatoryThe present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.5.2TableenclosureTSTablenot-accessibleoptionalA List of TempSensor Entries containing Information/Properties about the enclosure TempSensor
1.3.6.1.4.1.3582.5.1.4.4.5.2.1RowenclosureTSEntrynot-accessiblemandatoryAn Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.1ColumntempSensorIDread-onlyoptionalID for this TempSensor.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.2ColumnencIdread-onlyoptionalenclosure id for this TempSensor
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.3ColumntempSensorStatusread-onlyoptionalstatus of this tempSensor
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.4ColumntsTemperatureread-onlyoptionalCurrent temperature in degree Centigrade
1.3.6.1.4.1.3582.5.1.4.4.6NodeenclosureAlarmInfo
1.3.6.1.4.1.3582.5.1.4.4.6.1ScalarenclosureAlarmNumberread-onlymandatoryThe present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.6.2TableenclosureAlarmTablenot-accessibleoptionalA List of Alarm Entries containing Information/Properties about enclosure Alarms
1.3.6.1.4.1.3582.5.1.4.4.6.2.1RowenclosureAlarmEntrynot-accessiblemandatoryAn Entry in the enclosureAlarm table.
1.3.6.1.4.1.3582.5.1.4.4.6.2.1.1ColumnalarmIDread-onlyoptionalID for this Alarm.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.6.2.1.2ColumnalmEnclosureIdread-onlyoptionalEnclosure id where the Alarm is attached
1.3.6.1.4.1.3582.5.1.4.4.6.2.1.3ColumnalarmStatusread-onlyoptionalStatus of the alarm
1.3.6.1.4.1.3582.5.1.4.4.7NodeenclosureSIMInfo
1.3.6.1.4.1.3582.5.1.4.4.7.1ScalarenclosureSIMNumberread-onlymandatoryThe present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.7.2TableenclosureSIMTablenot-accessibleoptionalA List of SIM Entries containing Information/Properties about enclosure SIMs
1.3.6.1.4.1.3582.5.1.4.4.7.2.1RowenclosureSIMEntrynot-accessiblemandatoryAn Entry in the enclosureSIM table.
1.3.6.1.4.1.3582.5.1.4.4.7.2.1.1ColumnsimIDread-onlyoptionalID for this SIM.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.7.2.1.2ColumnsimEnclosureIdread-onlyoptionalEnclosure id where the SIM is attached
1.3.6.1.4.1.3582.5.1.4.4.7.2.1.3ColumnsimStatusread-onlyoptionalNumber of Logical Drives Configured on this Adapter.
1.3.6.1.4.1.3582.5.1.4.5Nodetopology
1.3.6.1.4.1.3582.5.1.4.5.1NodephyInfo
1.3.6.1.4.1.3582.5.1.4.5.1.1ScalarphyNumberread-onlymandatoryThe present number of rows in the Phy table.
1.3.6.1.4.1.3582.5.1.4.5.1.2TablephyTablenot-accessibleoptionalA List of phy Entries containing Information/Properties about the sas topology in the system.
1.3.6.1.4.1.3582.5.1.4.5.1.2.1RowphyEntrynot-accessiblemandatoryAn Entry in the Phy table.
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.1ColumnphyIndexread-onlyoptionalIndex for this phy.(Unique)
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.2ColumndeviceIndexread-onlyoptionalIndex of the device in tDeviceTable where the phy is attached
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.3ColumndeviceTyperead-onlyoptionalType of device attached to this phy NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4)
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.4ColumnphyIDread-onlyoptionalThe phy ID of the attached device
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.5ColumndeviceOffsetread-onlyoptionalThe memory offset where the node of the device that is attached to this phy starts.
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.6ColumnphyPosread-onlyoptionalPosition of the Phy in device attached.
1.3.6.1.4.1.3582.5.1.4.5.2NodedevicesInTopology
1.3.6.1.4.1.3582.5.1.4.5.2.1ScalartDeviceNumberread-onlymandatoryThe present number of rows in the topology Device table.
1.3.6.1.4.1.3582.5.1.4.5.2.2TabletDeviceTablenot-accessibleoptionalA List of device Entries containing Information/Properties about the sas topology in the system.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1RowtDeviceEntrynot-accessiblemandatoryAn Entry in the tDevice table.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.1ColumntDeviceIndexread-onlyoptionalIndex for this device.(Unique)
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.2ColumncontIDread-onlyoptionalAdapter ID where this device is attached
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.3ColumntDeviceIdread-onlyoptionalDevice ID.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.4ColumntDeviceTyperead-onlyoptionalNO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4)
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.5ColumntParentIndexread-onlyoptionalIndex of the parent device in the table where this device is connected. -1 if it root device.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.6ColumntNumPhyread-onlyoptionalTotal no of Phy present in this device
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.7ColumntSASAddrread-onlyoptionalDevice SAS addresses. Comma separeted for multiple address
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.8ColumntDevDescriptionread-onlyoptionalDetailed description of the Device.
1.3.6.1.4.1.3582.5.1.4.6Nodelsi-SAS-Traps
1.3.6.1.4.1.3582.5.1.4.6.1001ScalaratAdpNumberread-onlyoptionalAdapter ID for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1002ScalaratAlarmStateread-onlyoptionalAlarm disabled(0)/enabled(1)
1.3.6.1.4.1.3582.5.1.4.6.1003ScalaratRateread-onlyoptionalBGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate
1.3.6.1.4.1.3582.5.1.4.6.1004ScalaratFlashImageNameread-onlyoptionalFlash Image Name
1.3.6.1.4.1.3582.5.1.4.6.1005ScalaratSensorNumread-onlyoptionalSensor Number
1.3.6.1.4.1.3582.5.1.4.6.1006ScalaratThresholdread-onlyoptionalThreshold
1.3.6.1.4.1.3582.5.1.4.6.1007ScalaratTemperatureread-onlyoptionalTemperature Exceeded
1.3.6.1.4.1.3582.5.1.4.6.1008ScalardevLiferead-onlyoptionalDrive Life
1.3.6.1.4.1.3582.5.1.4.6.1009ScalaratWarningLevelread-onlyoptionalWarning Level
1.3.6.1.4.1.3582.5.1.4.6.1010ScalaratErrorLevelread-onlyoptionalError Level
1.3.6.1.4.1.3582.5.1.4.6.1011ScalarThrottleread-onlyoptionalThrottle
1.3.6.1.4.1.3582.5.1.4.6.1012ScalarPercentThrottleread-onlyoptionalPercent Throttle
1.3.6.1.4.1.3582.5.1.4.6.1013ScalarPCISlotAvailPowerread-onlyoptionalPCI Slot Avail Power
1.3.6.1.4.1.3582.5.1.4.6.1014ScalarFlagsread-onlyoptionalFlags SENSOR(1)|SLOT(2)
1.3.6.1.4.1.3582.5.1.4.6.1015ScalarSensorOrSlotread-onlyoptionalSensor Or Slot depending on the value of thr Flag
1.3.6.1.4.1.3582.5.1.4.6.1016ScalarCurrTempread-onlyoptionalCurrent Temp
1.3.6.1.4.1.3582.5.1.4.6.1017ScalarThresholdTempread-onlyoptionalThreshold Temp
1.3.6.1.4.1.3582.5.1.4.6.1101ScalarvdNumread-onlyoptionalVirtual Drive Target ID for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1102ScalarvdSeqread-onlyoptionalVirtual Drive Sequence no for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1103ScalarvdProgread-onlyoptionalprogress %
1.3.6.1.4.1.3582.5.1.4.6.1104ScalarvdCachePolicyChangeReasonread-onlyoptionalVirtual Drive cache policy.
1.3.6.1.4.1.3582.5.1.4.6.1105ScalarvdNewStateread-onlyoptionalVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
1.3.6.1.4.1.3582.5.1.4.6.1106ScalarvdOldStateread-onlyoptionalVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
1.3.6.1.4.1.3582.5.1.4.6.1201ScalarpdIDread-onlyoptionalDevice ID for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1202ScalarpdEncIndexread-onlyoptionalEnclosure index(0 means not within an enclosure) for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1203ScalarpdSlotNoread-onlyoptionalSlot no for the enclosure
1.3.6.1.4.1.3582.5.1.4.6.1204ScalarpdNewStateread-onlyoptionalPhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
1.3.6.1.4.1.3582.5.1.4.6.1205ScalarpdOldStateread-onlyoptionalPhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
1.3.6.1.4.1.3582.5.1.4.6.1206ScalarpdCDBDataread-onlyoptionalCDB Data.
1.3.6.1.4.1.3582.5.1.4.6.1207ScalarpdSenseDataread-onlyoptionalSence Data.
1.3.6.1.4.1.3582.5.1.4.6.7001NodeirAdpAlarmStateEnabledAlarm has been enabled by user for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7002NodeirAdpBGIRateChangedBackground initialization rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.7003NodeirAdpCacheDiscardedController $1 cache discarded due to memory/battery problems
1.3.6.1.4.1.3582.5.1.4.6.7004NodeirAdpCacheRebootCantRecoverUnable to recover cache data due to configuration mismatch for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7005NodeirAdpCacheRebootRecoverCache data recovered successfully for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7006NodeirAdpCacheVersionMismatchController cache discarded due to firmware version incompatibility for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7007NodeirAdpCCRateChangedConsistency Check rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.7008NodeirAdpFlashBadImageFlash downloaded image corrupted for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7009NodeirAdpFlashEraseErrorFlash erase error for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7010NodeirAdpFlashEraseTimeoutFlash timeout during erase for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7011NodeirAdpFlashGeneralErrorFlash error for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7012NodeirAdpFlashImageFlashing image: $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.7013NodeirAdpFlashOKFlash of new firmware image(s)complete for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7014NodeirAdpFlashProgramErrorFlash programming error for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7015NodeirAdpFlashProgramTimeoutFlash timeout during programming for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7016NodeirAdpLogClearedEvent log cleared for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7017NodeirAdpLogWrappedEvent log wrapped for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7018NodeirAdpPatrolReadCompletePatrol Read complete for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7019NodeirAdpPatrolReadPausedPatrol Read paused for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7020NodeirAdpPatrolReadResumedPatrol Read resumed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7021NodeirAdpPatrolReadStartedPatrol Read started for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7022NodeirAdpShutdownShutdown command received for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7023NodeirAdpHibernateHibernate command received for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7024NodeirAdpCrashFatal error received for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7025NodeirAdpRRChangedRebuild rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.7026NodeirAdpPRRateChangedPatrol Read rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.7027NodeirAdpAlarmStateDisabledAlarm has been disabled by user for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7028NodeirAdpConfigClearedConfiguration cleared for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7029NodeirAdpReconRateChangedReconstruction rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.7030NodeirAdpDefaultFactory defaults restored for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7031NodeirAdpThresholdsExceededCriticalAdapter $1 on sensor $2 has exceeded critical temperature threshold $3 Temperature $4
1.3.6.1.4.1.3582.5.1.4.6.7032NodeirAdpThresholdsExceededWarningAdapter $1 on sensor $2 has exceeded warning temperature threshold $3 Temperature $4
1.3.6.1.4.1.3582.5.1.4.6.7033NodeirAdpBRMFailedBackup Rail Monitor has failed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7034NodeirAdpSSDLifeExhaustedAdapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6
1.3.6.1.4.1.3582.5.1.4.6.7035NodeirAdpSSDLifeWarningAdapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6
1.3.6.1.4.1.3582.5.1.4.6.7036NodeirAdpSSDThrottlingRemovedThrottling Removed for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4
1.3.6.1.4.1.3582.5.1.4.6.7037NodeirAdpSSDThrottlingOccuringThrottling Occuring for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4
1.3.6.1.4.1.3582.5.1.4.6.7038NodeirAdpPowerThrottlingRemovedPower Throttling is Removed for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3
1.3.6.1.4.1.3582.5.1.4.6.7039NodeirAdpPowerThrottlingOccuringPower Throttling is Occuring for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3
1.3.6.1.4.1.3582.5.1.4.6.7040NodeirAdpDFFTempExceededWarningAdapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6
1.3.6.1.4.1.3582.5.1.4.6.7041NodeirAdpDFFTempExceededCriticalAdapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6
1.3.6.1.4.1.3582.5.1.4.6.7101NodeirVdtBGIAbortedBGI aborted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7102NodeirVdtBGICompletedBGI completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7103NodeirVdtBGIDoneWRBGI completed with uncorrectable errors on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7104NodeirVdtBGIFailedBGI failed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7105NodeirVdtBGIStartedBGI started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7107NodeirVdtCCStartedCC started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7108NodeirVdtCCCompletedCC completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7109NodeirVdtCCFailedCC failed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7110NodeirVdtCCAbortedCC aborted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7111NodeirVdtCCCompCorCC completed with correction on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7112NodeirVdtInitAbortedInitialization aborted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7113NodeirVdtInitFailedInitialization failed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7114NodeirVdtInitCompletedInitialization completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7115NodeirVdtInitFastStartedFast Initialization started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7116NodeirVdtInitFullStartedFull Initialization started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7117NodeirVdtReconStartedReconstructoin started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7118NodeirVdtReconCompletedReconstruction completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7119NodeirVdtReconResumedReconstruction resumed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7120NodeirVdtReconStoppedReconstruction stopped on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7121NodeirVdtStateChangeVD state changed on Adapter -$1 VD Target -$2 from $3 to $4
1.3.6.1.4.1.3582.5.1.4.6.7122NodeirVdtCreatedA new VD created on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7123NodeirVdtDeletedA VD deleted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.7201NodeirPdtClearAbortedPD Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7202NodeirPdtClearFailedPD Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7203NodeirPdtClearStartedPD Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7204NodeirPdtClearCompletedPD Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7205NodeirPdtErrorError occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7206NodeirPdtFormatStartPD format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7207NodeirPdtFormatCompletedPD format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7208NodeirPdtInsertedPD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7209NodeirPdtRblAbortedRebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7210NodeirPdtRblCompletedRebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7211NodeirPdtRblFailedBSRebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7212NodeirPdtRblFailedBTRebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7213NodeirPdtRblStartRebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7214NodeirPdtRblResumedRebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7215NodeirPdtRblStartARebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7216NodeirPdtRemovedPD removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7217NodeirPdtStateChangePD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6
1.3.6.1.4.1.3582.5.1.4.6.7218NodeirPdtSENSEAlertAn unexpected Sense was detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 CDBData -$5 SenseData -$6
1.3.6.1.4.1.3582.5.1.4.6.7219NodeirPdtPredictiveThresholdExceedPredictive Threshold Exceeded on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7220NodeirPdSSDSecurityLockedSSD is in locked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7221NodeirPdSSDSecurityUnlockedSSD is in unlocked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.7301NodeirBbuPresentBattery Present for Adapter %d
1.3.6.1.4.1.3582.5.1.4.6.7302NodeirBbuNotPresentBattery Not Present for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7303NodeirBbuNewBatteryNew Battery for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7304NodeirBbuReplacedBattery replaced for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7305NodeirBbuTempHighBattery temperature high for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7306NodeirBbuVoltageLowBattery voltage low for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7307NodeirBbuChargingBattery started charging for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7308NodeirBbuDisChargingBattery is discharging for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7309NodeirBbuTempNormalBattery temperature is normal for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7310NodeirBbuReplaceBattery needs replacement, SOH Bad for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7311NodeirBbuRelearnStartedBattery relearn started for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7312NodeirBbuRelearnProgressBattery relearn in progress for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7313NodeirBbuRelearnCompleteBattery relearn completed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7314NodeirBbuRelearnTimeoutBattery relearn timed out for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7315NodeirBbuRelearnPendingBattery relearn pending: Battery is under charge for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7316NodeirBbuRelearnPostponedBattery relearn postponed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7317NodeirBbuRemovedBattery removed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7318NodeirBbuCapacityLowCurrent capacity of the battery is below threshold for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.7319NodeirBbuCapacityAboveCurrent capacity of the battery is above threshold for Adapter $1
1.3.6.1.4.1.3582.5.1.8NodecopyrightInfo
1.3.6.1.4.1.3582.5.1.8.1Scalarcopyrightread-onlymandatoryLSI LOGIC