LSI-megaRAID-SAS-IR-MIB
472 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises Gauge |
| RFC1213-MIB | DisplayString PhysAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3582 | Nodelsi | |||
| 1.3.6.1.4.1.3582.5 | NodelsiStorageComponents | |||
| 1.3.6.1.4.1.3582.5.1 | NodelsiRAIDServer | |||
| 1.3.6.1.4.1.3582.5.1.1 | ScalarhostName | read-only | mandatory | Name of the host system. |
| 1.3.6.1.4.1.3582.5.1.2 | ScalarhostOSInfo | read-only | mandatory | Operating System description where SNMP agent is running. |
| 1.3.6.1.4.1.3582.5.1.3 | NodeversionInfo | |||
| 1.3.6.1.4.1.3582.5.1.3.1 | ScalarmibVersion | read-only | mandatory | The MIB version no. (xx.yy.zz) |
| 1.3.6.1.4.1.3582.5.1.3.2 | ScalaragentModuleName | read-only | mandatory | The agent module name |
| 1.3.6.1.4.1.3582.5.1.3.3 | ScalaragentModuleVersion | read-only | mandatory | The module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information). |
| 1.3.6.1.4.1.3582.5.1.3.4 | ScalarreleaseDate | read-only | mandatory | Module Release Date (DD/MM/YYYY) |
| 1.3.6.1.4.1.3582.5.1.4 | NodemegaRAID-SAS-IR | |||
| 1.3.6.1.4.1.3582.5.1.4.1 | Nodeadapter | |||
| 1.3.6.1.4.1.3582.5.1.4.1.1 | NodeadapterDetails | |||
| 1.3.6.1.4.1.3582.5.1.4.1.1.1 | ScalaradpNumber | read-only | mandatory | The total no of SAS adapters present. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2 | TableadapterPropertiesTable | not-accessible | optional | A List of adapter Entries containing Information/Properties about the adapters. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1 | RowadapterPropertiesEntry | not-accessible | mandatory | An Entry in the adapter table. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.1 | ColumnadapterID | read-only | optional | AdapterID for this Adapter.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.2 | ColumnrebuildRate | read-only | optional | Rebuild rate on this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.3 | ColumnreconstructionRate | read-only | optional | Reconstruction rate on this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.4 | ColumnalarmState | read-only | optional | Alarm is enabled(1) or disabled(0) on this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.5 | ColumncacheFlushInterval | read-only | optional | Cache flush interval in seconds for this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.6 | ColumnclusterState | read-only | optional | Cluster is enabled(1) or disabled(0) on this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.7 | ColumnpredFailPollInterval | read-only | optional | Number of seconds between predictive fail polls on this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.8 | ColumnintThrottleCount | read-only | optional | Interrupt throttle active count on this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.9 | ColumnintThrottleTimeUs | read-only | optional | Interrupt throttle completion hold time on this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.10 | ColumnpatrolReadRate | read-only | optional | Patrol Read Rate for this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.11 | ColumnbgiRate | read-only | optional | Background initialization rate for this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.12 | ColumnccRate | read-only | optional | Consistency Check rate on this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.13 | ColumnspinupDelay | read-only | optional | Number of seconds to delay among spinup groups for this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.14 | ColumnspinupDriveCount | read-only | optional | Maximum number of drives to spin up at one time for this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.15 | ColumncoercionMode | read-only | optional | Drive capacity coercion mode. 0->None; 1->128MB; 2->1GB; 3->Adaptive Coercion. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.16 | ColumndisableAutoRebuild | read-only | optional | auto-rebuild and hot-spare commissioning status. 1->Disable , 0->Enable |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.17 | ColumndisableBatteryWarning | read-only | optional | disable/enable warnings for missing battery or missing HW status. 1->Disable , 0->Enable |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.18 | ColumnmultipathSupport | read-only | optional | Multipath is supported or not supported on this adapter.Values: not supported(0),supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.19 | ColumnssdSMARTerEnabled | read-only | optional | Copyback to SSD on SMART error. Values Enabled(0),Disabled(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.20 | ColumnsasAddr | read-only | optional | This field gives the controller SAS address |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.21 | ColumnauxilaryPowerPresent | read-only | optional | Presence of Auxilary Power |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.22 | ColumnddLifeCurveStatus | read-only | optional | Check for throttling |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.23 | ColumnddSSDLifeLeft | read-only | optional | Percentage of SSD life left |
| 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.24 | ColumndDStatus | read-only | optional | Overall DD status |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3 | TableadapterInfoTable | not-accessible | optional | A List of adapter Entries containing Information/Properties about the adapters. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1 | RowadapterInfoEntry | not-accessible | mandatory | An Entry in the adapterInfo table. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.1 | ColumninfAdpID | read-only | optional | AdapterID for this Adapter.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.2 | ColumnvendorId | read-only | optional | PCI Vendor ID for this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.3 | ColumndevId | read-only | optional | PCI Device ID for this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.4 | ColumnsubVendorID | read-only | optional | PCI Sub-Vendor ID for this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.5 | ColumnsubDevID | read-only | optional | PCI Sub-Device ID for this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.6 | ColumnhostInterface | read-only | optional | Host interface information for this adapter. Values are as follows: N/A(0), PCIX(1), PCIE(2), iSCSI(3), SAS_3G(4) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.7 | ColumnhostInterfacePortCnt | read-only | optional | Port Count on this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.8 | ColumnhostInterfacePortAddr | read-only | optional | Port address comma delimited |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.9 | ColumndevInterface | read-only | optional | Multiple device interface support values separated by space. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.10 | ColumndevInterfacePortCnt | read-only | optional | Device Port Count on this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.11 | ColumndevInterfacePortAddr | read-only | optional | Device Port address comma delimited |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.12 | ColumnproductName | read-only | optional | Product name e.g. SAS2008 B1. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.13 | ColumnserialNo | read-only | optional | Controller serial number |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.14 | ColumnfirmwareVersion | read-only | optional | Firmware version Format->(Firmware Package Version:Version:Date:Time) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.15 | ColumndriverVersion | read-only | optional | Driver version Format->(Driver Name:Version) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.16 | ColumnnvramSize | read-only | optional | NVRAM size in KB for this adapter.A value -1 for invalid or undefined size. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.17 | ColumnmemorySize | read-only | optional | Memory size in MB for this adapter.A value -1 for invalid or undefined size. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.18 | ColumnflashSize | read-only | optional | Flash size in MB for this adapter.A value -1 for invalid or undefined size. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.19 | ColumnvdPresentCount | read-only | optional | Virtual devices present in this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.20 | ColumnvdDegradedCount | read-only | optional | Number of virtual devices in this adapter that are critical |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.21 | ColumnvdOfflineCount | read-only | optional | Number of virtual devices in this adapter that are offline |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.22 | ColumnpdPresentCount | read-only | optional | Physical devices present in this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.23 | ColumnpdDiskPresentCount | read-only | optional | Physical disk devices present in this adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.24 | ColumnpdDiskPredFailureCount | read-only | optional | Number of disk devices in this adapter that are critical |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.25 | ColumnpdDiskFailedCount | read-only | optional | Number of disk devices in this adapter that are failed |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.26 | ColumnclusterStatus | read-only | optional | Cluster state on this adapter. Values: ACTIVE(1), INACTIVE(0) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.27 | ColumndevInterfaceType | read-only | optional | Type of the interface of the IR adapter. Values: GEN1(0), GEN2(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4 | TableadapterSupportInfoTable | not-accessible | optional | A List of Entries containing Properties supported by the Controller. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1 | RowadapterSupportInfoEntry | not-accessible | mandatory | An Entry in the adapter table. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.1 | ColumnsuAdpID | read-only | optional | AdapterID for this Adapter.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.2 | ColumnsupportMaxArms | read-only | optional | Maximum arms per Logical Drive supported for this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.3 | ColumnsupportMaxSpans | read-only | optional | Maximum spans per Logical Drive supported for this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.4 | ColumnsupportMaxArrays | read-only | optional | Maximum number arrays supported this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.5 | ColumnsupportMaxLDs | read-only | optional | Maximum number of Logical Drive's supported for this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.6 | ColumnsupportHardwarePresent | read-only | optional | Supported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4). For multiple hardware support a comma delimited list will appear. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.7 | ColumnsupportMaxConcurrentCmds | read-only | optional | The maximum parallel commands supported on this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.8 | ColumnsupportMaxSGECount | read-only | optional | The maximum Scatter Gather Element count allowed on this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.9 | ColumnsupportMaxRequestSize | read-only | optional | The maximum data transfer size in sectors, on this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.10 | ColumnsupportClusterPermitted | read-only | optional | Clustering support on this Adapter. Values: FALSE(0), TRUE(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.11 | ColumnsupportMinStripeSize | read-only | mandatory | Minimum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.12 | ColumnsupportMaxStripeSize | read-only | mandatory | Maximum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.13 | ColumnsupportSupportsSAS | read-only | mandatory | SAS physical drive support.Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.14 | ColumnsupportSupportsSATA | read-only | mandatory | SATA physical drive support.Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.15 | ColumnsupportAllowMixInEnclosure | read-only | mandatory | Mix InEnclosure support.Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.16 | ColumnsupportAllowMixInVD | read-only | mandatory | MixInVD support.Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.17 | ColumnsupportAllowSataInCluster | read-only | mandatory | SataInCluster support. Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.18 | ColumnallowSSDMixInLD | read-only | mandatory | allow SAS/SATA SSD mix within an LD. allow(1), not allow(0) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.19 | ColumnallowMixSSDHDDInLD | read-only | mandatory | allow SSD/HDD mix within an LD.allow(1), not allow(0) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5 | TableadpOperationsSupportInfoTable | not-accessible | optional | A List of Entries containing operations supported by the Controller. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1 | RowadpOperationsSupportInfoEntry | not-accessible | mandatory | An Entry in the adapter table. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.1 | ColumnopAdpID | read-only | optional | AdapterID for this Adapter.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.2 | ColumnrbldRate | read-only | optional | Rebuilding rate change support for this Adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.3 | ColumnsuCCRate | read-only | optional | Consistency Check rate change support for this Adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.4 | ColumnsuBgiRate | read-only | optional | Background initialization rate change support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.5 | ColumnreconRate | read-only | optional | Reconstruction rate change support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.6 | ColumnpatrolRate | read-only | optional | Patrol read rate change support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.7 | ColumnalarmControl | read-only | optional | Alarm control support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.8 | ColumnclusterSupported | read-only | optional | Cluster support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.9 | Columnbbu | read-only | optional | BBU support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.10 | ColumnspanningAllowed | read-only | optional | Spanning support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.11 | ColumndedicatedHotSpares | read-only | optional | Dedicated HotSpares for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.12 | ColumnrevertibleHotSpares | read-only | optional | Revertible HotSpares support for this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.13 | ColumnforeignConfigImport | read-only | optional | Support foreign config import on this adapter. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.14 | ColumnselfDiagnostic | read-only | optional | Controller supports self diagnostic. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.15 | ColumnallowMixedRedundancyOnArray | read-only | optional | Allow different Virtual Disk on the same array to have different redundancy levels Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.16 | ColumnglobalHotSpares | read-only | optional | Global hot spares are supported. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.17 | ColumnoceWithNoDriveAddition | read-only | optional | Online Capacity Expansion supported. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.6 | TabledriveOperationSupportTable | not-accessible | optional | A List of operations supported by Physical Drive. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.6.1 | RowdriveOperationSupportEntry | not-accessible | mandatory | An Entry in the driveOperationSupport table. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.1 | ColumndrvAdpID | read-only | mandatory | Unique adapter ID |
| 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.2 | ColumnforceOnline | read-only | mandatory | Physical Drive force Online operation support Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.3 | ColumnforceOffline | read-only | mandatory | Physical Drive force Offline operation support Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.4 | ColumnforceRebuild | read-only | mandatory | Physical Drive force Rebuild operation support Values: notSupported(0), supported(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7 | TablevdOperationSupportTable | not-accessible | optional | A List operations supported by Virtual Drive |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7.1 | RowvdOperationSupportEntry | not-accessible | mandatory | An Entry in the vdOperationSupport Table. |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.1 | ColumnvdOpAdpID | read-only | mandatory | Unique adapter ID |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.2 | ColumnreadPolicy | read-only | mandatory | Read policy support. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.3 | ColumnwritePolicy | read-only | mandatory | Write policy support. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.4 | ColumnioPolicy | read-only | mandatory | IO policy support. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.5 | ColumnaccessPolicy | read-only | mandatory | Access policy support. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.6 | ColumndiskCachePolicy | read-only | mandatory | Disk Cache Policy support. Values: False(0), True(1) |
| 1.3.6.1.4.1.3582.5.1.4.1.2 | NodebbuInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.1.2.1 | ScalarbbuNumber | read-only | mandatory | The present number of rows in the bbuTable. |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2 | TablebbuTable | not-accessible | optional | A List of bbu Entries containing Information/Properties about the BBU. |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1 | RowbbuEntry | not-accessible | mandatory | An Entry in the BBU table. |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.1 | ColumnbbuID | read-only | optional | BBUID for this BBU.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.2 | ColumnbatteryType | read-only | optional | BBU Type: Values: n/a(0), ibbu(1), bbu(2), zcr_legacy(3), itbbu3(4) |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.3 | ColumnnextLearnTime | read-only | optional | Time of next scheduled lean cycle (seconds path 1/1/2000) |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.4 | ColumnabsStateOfCharge | read-only | optional | Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.5 | ColumnfullChargeCapacity | read-only | optional | Predicted pack capacity when it is fully charged in mAh |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.6 | ColumnaverageEmptyTime | read-only | optional | One-minute rolling average of the predicted remaining battery life. Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.7 | ColumncycleCount | read-only | optional | Number of charge cycles the battery has experienced. Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.8 | ColumnfirmwareStatus | read-only | optional | condition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) … |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.9 | Columnvoltage | read-only | optional | Accurate battery terminal voltage in mV, resolution of 1mV |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.10 | ColumnautoLearnPeriod | read-only | optional | Time (in seconds) between learn cycles (0 to disable auto learn) |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.11 | ColumnrelStateOfCharge | read-only | optional | Predicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.12 | ColumncapacityRemain | read-only | optional | Predicted charge or energy remaining in the battery in mAh |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.13 | ColumnrunTimeToEmpty | read-only | optional | (in minutes)Relative gain or loss in remaining life in response to change in power policy. Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.14 | ColumnavgTimeToFull | read-only | optional | One-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.15 | ColumnerrorMargin | read-only | optional | Expected margin of error (%) in charge calculation (2-100). Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.16 | Columntemperature | read-only | optional | Battery temperature in degree Centigrade |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.17 | ColumnmfgName | read-only | optional | Battery manufacturer's name |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.18 | ColumndeviceName | read-only | optional | Battery name |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.19 | ColumnserialNumber | read-only | optional | Battery serialNumber |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.20 | ColumnchargerStatus | read-only | optional | Battery charger status. Values: N/A(-1), off(0), complete(1), progress(2) |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.21 | ColumnadpID | read-only | optional | The adapter id where BBU is attached |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.22 | ColumnremainingCapAlarm | read-only | optional | Remaining capacity to alarm. Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.23 | ColumnremainingTimeAlarm | read-only | optional | Remaining time to alarm. Value of -1 means not supported |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.24 | Columnbbu-current | read-only | optional | Current(In mA) being supplied (or accepted) through the terminals of the battery |
| 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.25 | ColumngasGaugeStatus | read-only | optional | Gas guage status |
| 1.3.6.1.4.1.3582.5.1.4.2 | Nodedevice | |||
| 1.3.6.1.4.1.3582.5.1.4.2.1 | NodephysicalDriveInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.2.1.1 | ScalarpdNumber | read-only | mandatory | The present number of rows in the physicalDrive table. |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2 | TablepdTable | not-accessible | optional | A List of physicalDrive Entries containing Information/Properties about the drives |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1 | RowpdEntry | not-accessible | optional | An Entry in the Device Table. |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.1 | ColumnpdIndex | read-only | optional | The unique ID |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.2 | ColumnphysDevID | read-only | optional | The Device ID |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.3 | ColumnoemSupported | read-only | optional | Drive support by the OEM (OEM-specific checks) Values: notSupported(1), supported(0) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.4 | ColumnscsiDevType | read-only | optional | Type of this Device. Values: disk(0), tape(1), printer(2), processor(3), cdrom(5), scanner(6), optical(7), enclosure(13), dvd(10), unknown(31) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.5 | ColumnconnectedAdapterPort | read-only | optional | Adapter port to which the device is connected. |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.6 | ColumndeviceSpeed | read-only | optional | Maximum supported speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2),speed_6G(3) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.7 | ColumnmediaErrCount | read-only | optional | Error count of the device |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.8 | ColumnotherErrCount | read-only | optional | other error count of the device |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.9 | ColumnpredFailCount | read-only | optional | Predictive fail count of the device |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.10 | ColumnpdState | read-only | optional | Firmware's interpretation of drive state. Values: unconfigured_good(0), unconfigured_bad(1), hot_spare(2), offline(16), failed(17), rebuild(20), online(24),cop… |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.11 | ColumndisabledForRemoval | read-only | optional | If true, drive is ready for removal. Values: false(0), true(1) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.12 | ColumnlinkSpeed | read-only | optional | Negotiated link speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2), speed_6G(3) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.13 | ColumnpdSupportFlags | read-only | optional | 1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCS… |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.14 | ColumnpdSasAddr | read-only | optional | Device SAS addresses. Comma separeted for multiple address |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.15 | ColumnrawSize | read-only | optional | Size(MB) before COD and coercion |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.16 | ColumnnonCoercedSize | read-only | optional | Size(MB) after COD is reserved but before coercion |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.17 | ColumncoercedSize | read-only | optional | Size(MB) after COD is reserved and after coercion |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.18 | ColumnenclDeviceId | read-only | optional | Enclosure's device Id (in decimal); if device is not within enclosure value is -1 |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.19 | ColumnenclIndex | read-only | optional | Firmware internal enclosure index |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.20 | ColumnslotNumber | read-only | optional | Slot number of this drive, if this Physical Drive is an enclosure then -1 |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.21 | ColumnpdOperationProgress | read-only | optional | % Progress is %. e.g. Rebuild progress is 10% |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.22 | ColumnpdAdpID | read-only | optional | Controller id where this Physical Drive is attached |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.23 | ColumnoperationSupport | read-only | optional | Online,Offline,Failed,Bad,Uncofigured good,Unconfigured bad, Spare,Spare,replaceMissing,markMissing,startRebuild,stopRebuild, locate,stopSecureEraseNonSED,FWDo… |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.24 | ColumnvendorID | read-only | optional | Vendor ID |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.25 | ColumnproductID | read-only | optional | Product ID |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.26 | ColumnpdFwversion | read-only | optional | Physical drive firmware version |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.27 | ColumnpdSerialNumber | read-only | optional | Physical drive serial number |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.28 | ColumndiskType | read-only | optional | Type of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.29 | ColumnpartnerDevId | read-only | optional | If drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.30 | Columnmediatype | read-only | optional | Media Type HDD(0),SSD(1) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.31 | ColumnoemCertified | read-only | optional | Indicates whether device is certified(0) or not(1) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.32 | ColumnpdTemperature | read-only | optional | Physical Drive temperature in Celsius |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.33 | ColumnpiType | read-only | optional | SAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS … |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.34 | ColumnuserDataBlockSize | read-only | optional | Number of bytes of user data in LBA |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.35 | Columncage | read-only | optional | Current Cage that holds the SSD |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.36 | Columnlocation | read-only | optional | Current location of SSD 0 - Upper, 1 - Lower |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.37 | Columnwhtemperature | read-only | optional | Temperature of each SSD |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.38 | ColumnflashType | read-only | optional | Flash Type being used (SLC / MLC / EMLC) |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.39 | ColumnlifeCurveStatus | read-only | optional | 100 - No throttling being done, 90 - SSD is being throttled |
| 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.40 | ColumnsSDLifeLeft | read-only | optional | Percentage of SSD life left |
| 1.3.6.1.4.1.3582.5.1.4.3 | NodevirtualDevice | |||
| 1.3.6.1.4.1.3582.5.1.4.3.1 | NodevdInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.3.1.1 | ScalarvdNumber | read-only | mandatory | The present number of rows in the virtualDrive table. |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2 | TablevdTable | not-accessible | optional | A List of Virtual Drive Entries containing Information/Properties about the virtualDrive. |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1 | RowvdEntry | not-accessible | optional | An Entry in the virtualDrive Table. |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.1 | ColumnvirtualDevID | read-only | optional | The unique Virtual Drive ID |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.2 | Columnsize | read-only | optional | Total size in MB of the drive |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.3 | ColumnclusterOwnerDeviceId | read-only | optional | Virtual Drive owner's device Id |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.4 | ColumntargetId | read-only | optional | Virtual Drive target id (i.e. 0 to 63) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.5 | Columnstate | read-only | optional | Virtual Drive state. Values: offline(0), partially_degraded(1), degraded(2), optimal(3) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.6 | Columnname | read-only | optional | Virtual Drive name |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.7 | ColumndefaultCachePolicy | read-only | optional | Default cache policy settings. Values: direct_io(0), cached_io(1) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.8 | ColumnvdAccessPolicy | read-only | optional | Access policy settings. Values: access_rw(0), access_read_only(2), access_blocked(3) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.9 | ColumnvdDiskCachePolicy | read-write | optional | Physical disk cache policy. Values: enable(1), disable(2) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.10 | ColumnbgiState | read-only | optional | BGI state on this VD. Values disable(1), enable(0) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.11 | Columnprl | read-only | optional | Primay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E/10), 21(RAID-5E), 31(Concatenat… |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.12 | ColumnrLQ | read-only | optional | Raid level qualifier |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.13 | ColumnsRL | read-only | optional | Secondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned), -1(Not Supported for IR2) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.14 | ColumnstripeSize | read-only | optional | Stripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.15 | ColumnnumDrives | read-only | optional | Number of drivers per span |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.16 | ColumnspanDepth | read-only | optional | Number of spans. If only one array then it is considered as 1 span |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.17 | ColumninitState | read-only | optional | 0=no init, 1=quick init, 2=full init |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.18 | ColumncurrentCachePolicy | read-only | optional | Default cache policy settings. Values: direct_io(0), cached_io(1) |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.19 | ColumnoperationProgress | read-only | optional | Progress % for operation x/ No operation in progress |
| 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.20 | ColumnvdAdpID | read-only | optional | Controller id where this vd is present |
| 1.3.6.1.4.1.3582.5.1.4.3.2 | NodevdSpanInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.3.2.1 | ScalarvdSpanNumber | read-only | mandatory | The present number of rows in the virtualDrive table. |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2 | TablevdSpanTable | not-accessible | optional | A List of span Entries containing Information/Properties vd span. |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2.1 | RowvdSpanEntry | not-accessible | optional | An Entry in the vdSpan Table. |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.1 | ColumnspanID | read-only | optional | The unique Span ID |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.2 | ColumnvDevID | read-only | optional | The Virtual Device ID |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.3 | ColumnstartBlock | read-only | optional | Span physical disk starting block |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.4 | ColumnnumBlocks | read-only | optional | Span physical disk block count |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.5 | ColumnvdsArrayRef | read-only | optional | Array reference (index) |
| 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.6 | ColumnspAdpId | read-only | optional | Adapter where the span will be found |
| 1.3.6.1.4.1.3582.5.1.4.3.3 | NodearrayInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.3.3.1 | ScalararrayNumber | read-only | mandatory | The present number of rows in the array table. |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2 | TablearrayTable | not-accessible | optional | A List of array Entries containing Information/Properties about the arrays. |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2.1 | RowarrayEntry | not-accessible | optional | An Entry in the array Table. |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.1 | ColumnarrayID | read-only | optional | The unique array ID |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.2 | ColumnarrSize | read-only | optional | Size in MB |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.3 | ColumnarrNumDrives | read-only | optional | Number of drives for this array |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.4 | ColumnarrayRef | read-only | optional | Tag for the array |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.5 | ColumnpdList | read-only | optional | Space separated pd identification. e.g. {devID devID devID} etc |
| 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.6 | ColumnarrAdpId | read-only | optional | Adapter where the array will be found |
| 1.3.6.1.4.1.3582.5.1.4.3.4 | NodespareInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.3.4.1 | ScalarspareDevNumber | read-only | mandatory | The present number of rows in the sparepool table. |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2 | TablespareTable | not-accessible | optional | A List of sparepool Entries containing Information/Properties about the spare drive |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2.1 | RowspareEntry | not-accessible | optional | An Entry in the sparepool Table. |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.1 | ColumnspareID | read-only | optional | The unique Index |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.2 | ColumndeviceIdentification | read-only | optional | The Device ID |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.3 | ColumnspareType | read-only | optional | Spare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable. |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.4 | ColumnarrayCount | read-only | optional | The number of arrays to which the PD can be dedicated |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.5 | ColumnarrRef | read-only | optional | Comma separated array ids. e.g. 2,4,5 etc |
| 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.6 | ColumnsprAdpId | read-only | optional | Adapter where the spare will be found |
| 1.3.6.1.4.1.3582.5.1.4.4 | Nodeenclosure | |||
| 1.3.6.1.4.1.3582.5.1.4.4.1 | NodeenclosureInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.4.1.1 | ScalarenclosureNumber | read-only | mandatory | The present number of rows in the enclosure table. |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2 | TableenclosureTable | not-accessible | optional | A List of enclosure Entries containing Information/Properties about the enclosures in the system. |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1 | RowenclosureEntry | not-accessible | mandatory | An Entry in the enclosure table. |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.1 | ColumnenclosureID | read-only | optional | EnclosureID for this enclosure.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.2 | ColumndeviceId | read-only | optional | Enclosure device Id. |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.3 | ColumnenclosureIndex | read-only | optional | Firmware internal enclosure index |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.4 | ColumnslotCount | read-only | optional | Number of slots |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.5 | ColumnpsCount | read-only | optional | Number of power supplies |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.6 | ColumnfanCount | read-only | optional | Number of fans |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.7 | ColumntempSensorCount | read-only | optional | Number of temperature sensors |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.8 | ColumnalarmCount | read-only | optional | Number of alarms |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.9 | ColumnsimCount | read-only | optional | Number of SIM modules |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.10 | ColumnisFault | read-only | optional | Enclosure has entered a FAULT state or not. Values: false(0), true(1) |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.11 | ColumnpdCount | read-only | optional | Number of physical drives present |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.12 | ColumnpdIds | read-only | optional | Physical drive deviceId's comma separated. |
| 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.13 | ColumnencAdpID | read-only | optional | Adapter ID where this enclosure is connected |
| 1.3.6.1.4.1.3582.5.1.4.4.2 | NodeenclosureFanInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.4.2.1 | ScalarenclosureFanNumber | read-only | mandatory | The present number of rows in the enclosure fan table. |
| 1.3.6.1.4.1.3582.5.1.4.4.2.2 | TableenclosureFanTable | not-accessible | optional | A List of fan Entries containing Information/Properties about the enclosureFan. |
| 1.3.6.1.4.1.3582.5.1.4.4.2.2.1 | RowenclosureFanEntry | not-accessible | mandatory | An Entry in the enclosureFan table. |
| 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.1 | ColumnfanID | read-only | optional | ID for this enclosureFan.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.2 | ColumnenclosureId | read-only | optional | Enclosure ID where the fan is attached |
| 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.3 | ColumnfanStatus | read-only | optional | status of the device |
| 1.3.6.1.4.1.3582.5.1.4.4.3 | NodeenclosureSlotInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.4.3.1 | ScalarenclosureSlotNum | read-only | mandatory | The present number of rows in the enclosure slot table. |
| 1.3.6.1.4.1.3582.5.1.4.4.3.2 | TableenclosureSlotTable | not-accessible | optional | A List of slot Entries containing Information/Properties about the enclosure slots. |
| 1.3.6.1.4.1.3582.5.1.4.4.3.2.1 | RowenclosureSlotEntry | not-accessible | mandatory | An Entry in the enclosureSlot table. |
| 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.1 | ColumnslotID | read-only | optional | ID for this slot.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.2 | ColumnsltEncId | read-only | optional | Enclosure ID where the slot |
| 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.3 | ColumnslotStatus | read-only | optional | status of the device. Values: status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), sta… |
| 1.3.6.1.4.1.3582.5.1.4.4.4 | NodeenclosurePSInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.4.4.1 | ScalarenclosurePSNumber | read-only | mandatory | The present number of rows in the enclosure fan table. |
| 1.3.6.1.4.1.3582.5.1.4.4.4.2 | TableenclosurePSTable | not-accessible | optional | A List of powerSupply Entries containing Information/Properties about the enclosure powerSupply |
| 1.3.6.1.4.1.3582.5.1.4.4.4.2.1 | RowenclosurePSEntry | not-accessible | mandatory | An Entry in the powerSupply table. |
| 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.1 | ColumnpowerSupplyID | read-only | optional | ID for this powerSupply.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.2 | ColumnpsEnclosureId | read-only | optional | Enclosure id for the powerSupply |
| 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.3 | ColumnpowerSupplyStatus | read-only | optional | status of the power Supply |
| 1.3.6.1.4.1.3582.5.1.4.4.5 | NodeenclosureTSInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.4.5.1 | ScalarenclosureTSNumber | read-only | mandatory | The present number of rows in the enclosure fan table. |
| 1.3.6.1.4.1.3582.5.1.4.4.5.2 | TableenclosureTSTable | not-accessible | optional | A List of TempSensor Entries containing Information/Properties about the enclosure TempSensor |
| 1.3.6.1.4.1.3582.5.1.4.4.5.2.1 | RowenclosureTSEntry | not-accessible | mandatory | An Entry in the adapter table. |
| 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.1 | ColumntempSensorID | read-only | optional | ID for this TempSensor.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.2 | ColumnencId | read-only | optional | enclosure id for this TempSensor |
| 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.3 | ColumntempSensorStatus | read-only | optional | status of this tempSensor |
| 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.4 | ColumntsTemperature | read-only | optional | Current temperature in degree Centigrade |
| 1.3.6.1.4.1.3582.5.1.4.4.6 | NodeenclosureAlarmInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.4.6.1 | ScalarenclosureAlarmNumber | read-only | mandatory | The present number of rows in the enclosure fan table. |
| 1.3.6.1.4.1.3582.5.1.4.4.6.2 | TableenclosureAlarmTable | not-accessible | optional | A List of Alarm Entries containing Information/Properties about enclosure Alarms |
| 1.3.6.1.4.1.3582.5.1.4.4.6.2.1 | RowenclosureAlarmEntry | not-accessible | mandatory | An Entry in the enclosureAlarm table. |
| 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.1 | ColumnalarmID | read-only | optional | ID for this Alarm.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.2 | ColumnalmEnclosureId | read-only | optional | Enclosure id where the Alarm is attached |
| 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.3 | ColumnalarmStatus | read-only | optional | Status of the alarm |
| 1.3.6.1.4.1.3582.5.1.4.4.7 | NodeenclosureSIMInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.4.7.1 | ScalarenclosureSIMNumber | read-only | mandatory | The present number of rows in the enclosure fan table. |
| 1.3.6.1.4.1.3582.5.1.4.4.7.2 | TableenclosureSIMTable | not-accessible | optional | A List of SIM Entries containing Information/Properties about enclosure SIMs |
| 1.3.6.1.4.1.3582.5.1.4.4.7.2.1 | RowenclosureSIMEntry | not-accessible | mandatory | An Entry in the enclosureSIM table. |
| 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.1 | ColumnsimID | read-only | optional | ID for this SIM.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.2 | ColumnsimEnclosureId | read-only | optional | Enclosure id where the SIM is attached |
| 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.3 | ColumnsimStatus | read-only | optional | Number of Logical Drives Configured on this Adapter. |
| 1.3.6.1.4.1.3582.5.1.4.5 | Nodetopology | |||
| 1.3.6.1.4.1.3582.5.1.4.5.1 | NodephyInfo | |||
| 1.3.6.1.4.1.3582.5.1.4.5.1.1 | ScalarphyNumber | read-only | mandatory | The present number of rows in the Phy table. |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2 | TablephyTable | not-accessible | optional | A List of phy Entries containing Information/Properties about the sas topology in the system. |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2.1 | RowphyEntry | not-accessible | mandatory | An Entry in the Phy table. |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.1 | ColumnphyIndex | read-only | optional | Index for this phy.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.2 | ColumndeviceIndex | read-only | optional | Index of the device in tDeviceTable where the phy is attached |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.3 | ColumndeviceType | read-only | optional | Type of device attached to this phy NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4) |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.4 | ColumnphyID | read-only | optional | The phy ID of the attached device |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.5 | ColumndeviceOffset | read-only | optional | The memory offset where the node of the device that is attached to this phy starts. |
| 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.6 | ColumnphyPos | read-only | optional | Position of the Phy in device attached. |
| 1.3.6.1.4.1.3582.5.1.4.5.2 | NodedevicesInTopology | |||
| 1.3.6.1.4.1.3582.5.1.4.5.2.1 | ScalartDeviceNumber | read-only | mandatory | The present number of rows in the topology Device table. |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2 | TabletDeviceTable | not-accessible | optional | A List of device Entries containing Information/Properties about the sas topology in the system. |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1 | RowtDeviceEntry | not-accessible | mandatory | An Entry in the tDevice table. |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.1 | ColumntDeviceIndex | read-only | optional | Index for this device.(Unique) |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.2 | ColumncontID | read-only | optional | Adapter ID where this device is attached |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.3 | ColumntDeviceId | read-only | optional | Device ID. |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.4 | ColumntDeviceType | read-only | optional | NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4) |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.5 | ColumntParentIndex | read-only | optional | Index of the parent device in the table where this device is connected. -1 if it root device. |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.6 | ColumntNumPhy | read-only | optional | Total no of Phy present in this device |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.7 | ColumntSASAddr | read-only | optional | Device SAS addresses. Comma separeted for multiple address |
| 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.8 | ColumntDevDescription | read-only | optional | Detailed description of the Device. |
| 1.3.6.1.4.1.3582.5.1.4.6 | Nodelsi-SAS-Traps | |||
| 1.3.6.1.4.1.3582.5.1.4.6.1001 | ScalaratAdpNumber | read-only | optional | Adapter ID for which Trap is generated. |
| 1.3.6.1.4.1.3582.5.1.4.6.1002 | ScalaratAlarmState | read-only | optional | Alarm disabled(0)/enabled(1) |
| 1.3.6.1.4.1.3582.5.1.4.6.1003 | ScalaratRate | read-only | optional | BGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate |
| 1.3.6.1.4.1.3582.5.1.4.6.1004 | ScalaratFlashImageName | read-only | optional | Flash Image Name |
| 1.3.6.1.4.1.3582.5.1.4.6.1005 | ScalaratSensorNum | read-only | optional | Sensor Number |
| 1.3.6.1.4.1.3582.5.1.4.6.1006 | ScalaratThreshold | read-only | optional | Threshold |
| 1.3.6.1.4.1.3582.5.1.4.6.1007 | ScalaratTemperature | read-only | optional | Temperature Exceeded |
| 1.3.6.1.4.1.3582.5.1.4.6.1008 | ScalardevLife | read-only | optional | Drive Life |
| 1.3.6.1.4.1.3582.5.1.4.6.1009 | ScalaratWarningLevel | read-only | optional | Warning Level |
| 1.3.6.1.4.1.3582.5.1.4.6.1010 | ScalaratErrorLevel | read-only | optional | Error Level |
| 1.3.6.1.4.1.3582.5.1.4.6.1011 | ScalarThrottle | read-only | optional | Throttle |
| 1.3.6.1.4.1.3582.5.1.4.6.1012 | ScalarPercentThrottle | read-only | optional | Percent Throttle |
| 1.3.6.1.4.1.3582.5.1.4.6.1013 | ScalarPCISlotAvailPower | read-only | optional | PCI Slot Avail Power |
| 1.3.6.1.4.1.3582.5.1.4.6.1014 | ScalarFlags | read-only | optional | Flags SENSOR(1)|SLOT(2) |
| 1.3.6.1.4.1.3582.5.1.4.6.1015 | ScalarSensorOrSlot | read-only | optional | Sensor Or Slot depending on the value of thr Flag |
| 1.3.6.1.4.1.3582.5.1.4.6.1016 | ScalarCurrTemp | read-only | optional | Current Temp |
| 1.3.6.1.4.1.3582.5.1.4.6.1017 | ScalarThresholdTemp | read-only | optional | Threshold Temp |
| 1.3.6.1.4.1.3582.5.1.4.6.1101 | ScalarvdNum | read-only | optional | Virtual Drive Target ID for which Trap is generated. |
| 1.3.6.1.4.1.3582.5.1.4.6.1102 | ScalarvdSeq | read-only | optional | Virtual Drive Sequence no for which Trap is generated. |
| 1.3.6.1.4.1.3582.5.1.4.6.1103 | ScalarvdProg | read-only | optional | progress % |
| 1.3.6.1.4.1.3582.5.1.4.6.1104 | ScalarvdCachePolicyChangeReason | read-only | optional | Virtual Drive cache policy. |
| 1.3.6.1.4.1.3582.5.1.4.6.1105 | ScalarvdNewState | read-only | optional | Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) |
| 1.3.6.1.4.1.3582.5.1.4.6.1106 | ScalarvdOldState | read-only | optional | Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) |
| 1.3.6.1.4.1.3582.5.1.4.6.1201 | ScalarpdID | read-only | optional | Device ID for which Trap is generated. |
| 1.3.6.1.4.1.3582.5.1.4.6.1202 | ScalarpdEncIndex | read-only | optional | Enclosure index(0 means not within an enclosure) for which Trap is generated. |
| 1.3.6.1.4.1.3582.5.1.4.6.1203 | ScalarpdSlotNo | read-only | optional | Slot no for the enclosure |
| 1.3.6.1.4.1.3582.5.1.4.6.1204 | ScalarpdNewState | read-only | optional | Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) |
| 1.3.6.1.4.1.3582.5.1.4.6.1205 | ScalarpdOldState | read-only | optional | Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) |
| 1.3.6.1.4.1.3582.5.1.4.6.1206 | ScalarpdCDBData | read-only | optional | CDB Data. |
| 1.3.6.1.4.1.3582.5.1.4.6.1207 | ScalarpdSenseData | read-only | optional | Sence Data. |
| 1.3.6.1.4.1.3582.5.1.4.6.7001 | NodeirAdpAlarmStateEnabled | Alarm has been enabled by user for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7002 | NodeirAdpBGIRateChanged | Background initialization rate changed to $1 for Adapter $2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7003 | NodeirAdpCacheDiscarded | Controller $1 cache discarded due to memory/battery problems | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7004 | NodeirAdpCacheRebootCantRecover | Unable to recover cache data due to configuration mismatch for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7005 | NodeirAdpCacheRebootRecover | Cache data recovered successfully for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7006 | NodeirAdpCacheVersionMismatch | Controller cache discarded due to firmware version incompatibility for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7007 | NodeirAdpCCRateChanged | Consistency Check rate changed to $1 for Adapter $2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7008 | NodeirAdpFlashBadImage | Flash downloaded image corrupted for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7009 | NodeirAdpFlashEraseError | Flash erase error for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7010 | NodeirAdpFlashEraseTimeout | Flash timeout during erase for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7011 | NodeirAdpFlashGeneralError | Flash error for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7012 | NodeirAdpFlashImage | Flashing image: $1 for Adapter $2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7013 | NodeirAdpFlashOK | Flash of new firmware image(s)complete for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7014 | NodeirAdpFlashProgramError | Flash programming error for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7015 | NodeirAdpFlashProgramTimeout | Flash timeout during programming for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7016 | NodeirAdpLogCleared | Event log cleared for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7017 | NodeirAdpLogWrapped | Event log wrapped for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7018 | NodeirAdpPatrolReadComplete | Patrol Read complete for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7019 | NodeirAdpPatrolReadPaused | Patrol Read paused for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7020 | NodeirAdpPatrolReadResumed | Patrol Read resumed for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7021 | NodeirAdpPatrolReadStarted | Patrol Read started for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7022 | NodeirAdpShutdown | Shutdown command received for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7023 | NodeirAdpHibernate | Hibernate command received for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7024 | NodeirAdpCrash | Fatal error received for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7025 | NodeirAdpRRChanged | Rebuild rate changed to $1 for Adapter $2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7026 | NodeirAdpPRRateChanged | Patrol Read rate changed to $1 for Adapter $2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7027 | NodeirAdpAlarmStateDisabled | Alarm has been disabled by user for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7028 | NodeirAdpConfigCleared | Configuration cleared for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7029 | NodeirAdpReconRateChanged | Reconstruction rate changed to $1 for Adapter $2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7030 | NodeirAdpDefault | Factory defaults restored for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7031 | NodeirAdpThresholdsExceededCritical | Adapter $1 on sensor $2 has exceeded critical temperature threshold $3 Temperature $4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7032 | NodeirAdpThresholdsExceededWarning | Adapter $1 on sensor $2 has exceeded warning temperature threshold $3 Temperature $4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7033 | NodeirAdpBRMFailed | Backup Rail Monitor has failed for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7034 | NodeirAdpSSDLifeExhausted | Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7035 | NodeirAdpSSDLifeWarning | Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7036 | NodeirAdpSSDThrottlingRemoved | Throttling Removed for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7037 | NodeirAdpSSDThrottlingOccuring | Throttling Occuring for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7038 | NodeirAdpPowerThrottlingRemoved | Power Throttling is Removed for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7039 | NodeirAdpPowerThrottlingOccuring | Power Throttling is Occuring for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7040 | NodeirAdpDFFTempExceededWarning | Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7041 | NodeirAdpDFFTempExceededCritical | Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7101 | NodeirVdtBGIAborted | BGI aborted on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7102 | NodeirVdtBGICompleted | BGI completed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7103 | NodeirVdtBGIDoneWR | BGI completed with uncorrectable errors on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7104 | NodeirVdtBGIFailed | BGI failed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7105 | NodeirVdtBGIStarted | BGI started on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7107 | NodeirVdtCCStarted | CC started on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7108 | NodeirVdtCCCompleted | CC completed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7109 | NodeirVdtCCFailed | CC failed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7110 | NodeirVdtCCAborted | CC aborted on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7111 | NodeirVdtCCCompCor | CC completed with correction on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7112 | NodeirVdtInitAborted | Initialization aborted on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7113 | NodeirVdtInitFailed | Initialization failed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7114 | NodeirVdtInitCompleted | Initialization completed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7115 | NodeirVdtInitFastStarted | Fast Initialization started on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7116 | NodeirVdtInitFullStarted | Full Initialization started on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7117 | NodeirVdtReconStarted | Reconstructoin started on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7118 | NodeirVdtReconCompleted | Reconstruction completed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7119 | NodeirVdtReconResumed | Reconstruction resumed on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7120 | NodeirVdtReconStopped | Reconstruction stopped on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7121 | NodeirVdtStateChange | VD state changed on Adapter -$1 VD Target -$2 from $3 to $4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7122 | NodeirVdtCreated | A new VD created on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7123 | NodeirVdtDeleted | A VD deleted on Adapter -$1 VD Target -$2 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7201 | NodeirPdtClearAborted | PD Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7202 | NodeirPdtClearFailed | PD Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7203 | NodeirPdtClearStarted | PD Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7204 | NodeirPdtClearCompleted | PD Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7205 | NodeirPdtError | Error occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7206 | NodeirPdtFormatStart | PD format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7207 | NodeirPdtFormatCompleted | PD format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7208 | NodeirPdtInserted | PD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7209 | NodeirPdtRblAborted | Rebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7210 | NodeirPdtRblCompleted | Rebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7211 | NodeirPdtRblFailedBS | Rebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7212 | NodeirPdtRblFailedBT | Rebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7213 | NodeirPdtRblStart | Rebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7214 | NodeirPdtRblResumed | Rebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7215 | NodeirPdtRblStartA | Rebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7216 | NodeirPdtRemoved | PD removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7217 | NodeirPdtStateChange | PD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7218 | NodeirPdtSENSEAlert | An unexpected Sense was detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 CDBData -$5 SenseData -$6 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7219 | NodeirPdtPredictiveThresholdExceed | Predictive Threshold Exceeded on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7220 | NodeirPdSSDSecurityLocked | SSD is in locked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7221 | NodeirPdSSDSecurityUnlocked | SSD is in unlocked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7301 | NodeirBbuPresent | Battery Present for Adapter %d | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7302 | NodeirBbuNotPresent | Battery Not Present for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7303 | NodeirBbuNewBattery | New Battery for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7304 | NodeirBbuReplaced | Battery replaced for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7305 | NodeirBbuTempHigh | Battery temperature high for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7306 | NodeirBbuVoltageLow | Battery voltage low for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7307 | NodeirBbuCharging | Battery started charging for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7308 | NodeirBbuDisCharging | Battery is discharging for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7309 | NodeirBbuTempNormal | Battery temperature is normal for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7310 | NodeirBbuReplace | Battery needs replacement, SOH Bad for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7311 | NodeirBbuRelearnStarted | Battery relearn started for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7312 | NodeirBbuRelearnProgress | Battery relearn in progress for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7313 | NodeirBbuRelearnComplete | Battery relearn completed for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7314 | NodeirBbuRelearnTimeout | Battery relearn timed out for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7315 | NodeirBbuRelearnPending | Battery relearn pending: Battery is under charge for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7316 | NodeirBbuRelearnPostponed | Battery relearn postponed for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7317 | NodeirBbuRemoved | Battery removed for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7318 | NodeirBbuCapacityLow | Current capacity of the battery is below threshold for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.4.6.7319 | NodeirBbuCapacityAbove | Current capacity of the battery is above threshold for Adapter $1 | ||
| 1.3.6.1.4.1.3582.5.1.8 | NodecopyrightInfo | |||
| 1.3.6.1.4.1.3582.5.1.8.1 | Scalarcopyright | read-only | mandatory | LSI LOGIC |