MIB Viewer

Lambdatrail2s-MIB

149 objects
The MIB module for managing Deltanet Lambdatrail2-S device. Needs firmware 1.1.0 or higher.
Imported Objects
Deltanet-MIBdeltanet
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.35616.5Identitylambdatrail2sThe MIB module for managing Deltanet Lambdatrail2-S device. Needs firmware 1.1.0 or higher.
1.3.6.1.4.1.35616.5.0Nodelt2sNotifications
1.3.6.1.4.1.35616.5.0.1Notificationlt2sMgmtStartupcurrentThe agent has started up and is running.
1.3.6.1.4.1.35616.5.0.2Notificationlt2sMgmtAuthenticationFailurecurrentLogin has failed.
1.3.6.1.4.1.35616.5.0.3Notificationlt2sTemperatureHighcurrentDevice temperature is high.
1.3.6.1.4.1.35616.5.0.4Notificationlt2sTemperatureNormalcurrentDevice temperature is back to normal. Lower than 40 degrees celsius.
1.3.6.1.4.1.35616.5.0.5Notificationlt2sPowerSupplyPluggedIncurrentA power is plugged in.
1.3.6.1.4.1.35616.5.0.6Notificationlt2sPowerSupplyPluggedOutcurrentA power is plugged out.
1.3.6.1.4.1.35616.5.0.7Notificationlt2sPowerNormalcurrentA power goes on.
1.3.6.1.4.1.35616.5.0.8Notificationlt2sPowerFailurecurrentA power goes off.
1.3.6.1.4.1.35616.5.0.9Notificationlt2sFanOncurrentA fan goes on.
1.3.6.1.4.1.35616.5.0.10Notificationlt2sFanOffcurrentA fan goes off.
1.3.6.1.4.1.35616.5.0.11Notificationlt2sFanFailurecurrentA fan goes to failure.
1.3.6.1.4.1.35616.5.0.12Notificationlt2sMgmtSfpPluggedIncurrentSFP transceiver is plugged in on management port.
1.3.6.1.4.1.35616.5.0.13Notificationlt2sMgmtSfpPluggedOutcurrentSFP transceiver is plugged out on management port.
1.3.6.1.4.1.35616.5.0.14Notificationlt2sMgmtLinkUpcurrentA link goes up in one of the management ports.
1.3.6.1.4.1.35616.5.0.15Notificationlt2sMgmtLinkDowncurrentA link goes down in one of the management ports.
1.3.6.1.4.1.35616.5.0.16Notificationlt2sMgmtTxLowcurrentTransceiver TX power is low in the management port.
1.3.6.1.4.1.35616.5.0.17Notificationlt2sMgmtTxHighcurrentTransceiver TX power is high in the management port.
1.3.6.1.4.1.35616.5.0.18Notificationlt2sMgmtTxNormalcurrentTransceiver TX power is normal in the management port.
1.3.6.1.4.1.35616.5.0.19Notificationlt2sMgmtRxLowcurrentTransceiver RX power is low in the management port.
1.3.6.1.4.1.35616.5.0.20Notificationlt2sMgmtRxHighcurrentTransceiver RX power is high in the management port.
1.3.6.1.4.1.35616.5.0.21Notificationlt2sMgmtRxNormalcurrentTransceiver RX power is normal in the management port.
1.3.6.1.4.1.35616.5.0.22Notificationlt2sPortEnabledcurrentPort is administrative enabled.
1.3.6.1.4.1.35616.5.0.23Notificationlt2sPortDisabledcurrentPort is administrative disabled.
1.3.6.1.4.1.35616.5.0.24Notificationlt2sPortResetedcurrentA reset in one of the ports.
1.3.6.1.4.1.35616.5.0.25Notificationlt2sPortThermalShutdowncurrentA thermal shut down in one of the ports.
1.3.6.1.4.1.35616.5.0.26Notificationlt2sPortThermalWakeupcurrentA thermal wakeup in one of the ports.
1.3.6.1.4.1.35616.5.0.27Notificationlt2sLinePluggedIncurrentA SFP transceiver is plugged in, on one of the ports.
1.3.6.1.4.1.35616.5.0.28Notificationlt2sClientPluggedIncurrentA SFP transceiver is plugged in, on one of the ports.
1.3.6.1.4.1.35616.5.0.29Notificationlt2sLinePluggedOutcurrentA SFP transceiver is plugged out, on one of the ports.
1.3.6.1.4.1.35616.5.0.30Notificationlt2sClientPluggedOutcurrentA SFP transceiver is plugged out, on one of the ports.
1.3.6.1.4.1.35616.5.0.31Notificationlt2sLineLinkUpcurrentA SFP transceiver's link goes up in one of the ports.
1.3.6.1.4.1.35616.5.0.32Notificationlt2sClientLinkUpcurrentA SFP transceiver's link goes up in one of the ports.
1.3.6.1.4.1.35616.5.0.33Notificationlt2sLineLinkDowncurrentA SFP transceiver's link goes down in one of the ports.
1.3.6.1.4.1.35616.5.0.34Notificationlt2sClientLinkDowncurrentA SFP transceiver's link goes down in one of the ports.
1.3.6.1.4.1.35616.5.0.35Notificationlt2sLineLoopOncurrentA Line loop is activated in one of the ports.
1.3.6.1.4.1.35616.5.0.36Notificationlt2sLineLoopOffcurrentA Line loop is turned off in one of the ports.
1.3.6.1.4.1.35616.5.0.37Notificationlt2sClientLoopOncurrentA Client loop is activated in one of the ports.
1.3.6.1.4.1.35616.5.0.38Notificationlt2sClientLoopOffcurrentA Client loop is turned off in one of the ports.
1.3.6.1.4.1.35616.5.0.39Notificationlt2sPortTxLowcurrentA SFP transceiver TX power is low in one of the ports.
1.3.6.1.4.1.35616.5.0.40Notificationlt2sPortTxHighcurrentA SFP transceiver TX power is high in one of the ports.
1.3.6.1.4.1.35616.5.0.41Notificationlt2sPortTxNormalcurrentA SFP transceiver TX power is normal in one of the ports.
1.3.6.1.4.1.35616.5.0.42Notificationlt2sPortRxLowcurrentA SFP transceiver RX power is low in one of the ports.
1.3.6.1.4.1.35616.5.0.43Notificationlt2sPortRxHighcurrentA SFP transceiver RX power is high in one of the ports.
1.3.6.1.4.1.35616.5.0.44Notificationlt2sPortRxNormalcurrentA SFP transceiver RX power is normal in one of the ports.
1.3.6.1.4.1.35616.5.1Nodelt2sAgent
1.3.6.1.4.1.35616.5.1.1Scalarlt2sDescriptionread-onlycurrentShows the System Description.
1.3.6.1.4.1.35616.5.1.2Scalarlt2sDeviceTyperead-onlycurrentShows the Device Type.
1.3.6.1.4.1.35616.5.1.3Scalarlt2sHwRevisionread-onlycurrentShows the Device Type.
1.3.6.1.4.1.35616.5.1.4Scalarlt2sManufacturingDateread-onlycurrentShows the Device Type.
1.3.6.1.4.1.35616.5.1.5Scalarlt2sSerialNumberread-onlycurrentShows the serial number of the device.
1.3.6.1.4.1.35616.5.1.6Scalarlt2sSystemNameread-writecurrentThe assigned system name.
1.3.6.1.4.1.35616.5.1.7Scalarlt2sSystemLocationread-writecurrentSystem location.
1.3.6.1.4.1.35616.5.1.8Scalarlt2sSystemContactread-writecurrentThe responsible person.
1.3.6.1.4.1.35616.5.1.9Scalarlt2sSystemUptimeread-onlycurrentShows the time since the last restart of the management agent.
1.3.6.1.4.1.35616.5.1.10Scalarlt2sFirmwareVersionread-onlycurrentShows the software version of the agent running image.
1.3.6.1.4.1.35616.5.1.11Scalarlt2suCVersionread-onlycurrentShows the firmware version of the micro controller.
1.3.6.1.4.1.35616.5.1.12Scalarlt2sSaveRunningCfgread-writecurrentSet this variable will save current configuration. The value is set back to 1 after succeed.
1.3.6.1.4.1.35616.5.1.13Scalarlt2sResetAgentread-writecurrentSet this variable will reset the agent. The value is set back to 1 after reset.
1.3.6.1.4.1.35616.5.1.14Scalarlt2sSnmpGetCommunityread-writecurrentThe get community, read only.
1.3.6.1.4.1.35616.5.1.15Scalarlt2sSnmpSetCommunityread-writecurrentThe set community, read/write.
1.3.6.1.4.1.35616.5.1.16Scalarlt2sIp4DHCPread-writecurrentDHCP enable or disable. Default is off
1.3.6.1.4.1.35616.5.1.17Scalarlt2sIp4Addressread-writecurrentThe agent's administrative IP address. The current operational IP address can be obtained from the ipAdEntAddr in the ipAddrTable. This parameter will take eff…
1.3.6.1.4.1.35616.5.1.18Scalarlt2sIp4Maskread-writecurrentThe agent's administrative IP subnet mask. The current operational IP subnet mask can be obtained from the ipAdEntMask in the ipAddrTable. This parameter will …
1.3.6.1.4.1.35616.5.1.19Scalarlt2sIp4Gatewayread-writecurrentThe agent's administrative default gateway IP address. The current operational IP default gateway IP address can be obtained from the ipRouteDest in the ipRout…
1.3.6.1.4.1.35616.5.1.20Scalarlt2sIp4PrimaryDnsread-writecurrentFirst DNS server address.
1.3.6.1.4.1.35616.5.1.21Scalarlt2sIp4SecondaryDnsread-writecurrentSecond DNS server address.
1.3.6.1.4.1.35616.5.1.22Scalarlt2sSnmpServerread-writecurrent
1.3.6.1.4.1.35616.5.1.23Scalarlt2sHttpServerread-writecurrent
1.3.6.1.4.1.35616.5.1.24Scalarlt2sTelnetServerread-writecurrent
1.3.6.1.4.1.35616.5.1.25Scalarlt2sFtpServerread-writecurrent
1.3.6.1.4.1.35616.5.1.26Tablelt2sMgmtPortTablenot-accessiblecurrentA list of management port entries.
1.3.6.1.4.1.35616.5.1.26.1Rowlt2sMgmtPortEntrynot-accessiblecurrentAn entry containing information applicable to the management ports.
1.3.6.1.4.1.35616.5.1.26.1.1Columnlt2sMgmtPortIdread-onlycurrentThe management port identification. 1 Inband SFP, 2 LAN1, 3 LAN2.
1.3.6.1.4.1.35616.5.1.26.1.2Columnlt2sMgmtPortNameread-onlycurrentThe name of the management port
1.3.6.1.4.1.35616.5.1.26.1.3Columnlt2sMgmtPortEnableread-writecurrentThe enabled state of the port.
1.3.6.1.4.1.35616.5.1.26.1.4Columnlt2sMgmtPortLinkread-onlycurrentThe link state of the management port.
1.3.6.1.4.1.35616.5.1.26.1.5Columnlt2sMgmtPortSpeedread-onlycurrentThe speed mode of the port.
1.3.6.1.4.1.35616.5.1.26.1.6Columnlt2sMgmtPortTxBytesread-onlycurrentThe total amount of sent bytes.
1.3.6.1.4.1.35616.5.1.26.1.7Columnlt2sMgmtPortRxBytesread-onlycurrentThe total amount of received bytes.
1.3.6.1.4.1.35616.5.1.26.1.8Columnlt2sMgmtSfpPluggedread-onlycurrentThe line SFP plugged state of the port.
1.3.6.1.4.1.35616.5.1.26.1.9Columnlt2sMgmtSfpVendorread-onlycurrentThe vendor name of the SFP.
1.3.6.1.4.1.35616.5.1.26.1.10Columnlt2sMgmtSfpTyperead-onlycurrentThe vendor part name of the SFP.
1.3.6.1.4.1.35616.5.1.26.1.11Columnlt2sMgmtSfpSerialread-onlycurrentThe serial number of the SFP.
1.3.6.1.4.1.35616.5.1.26.1.12Columnlt2sMgmtSfpWavelengthread-onlycurrentThe SFP wavelength of the port. If the SFP is removed the object contains 'NA'.
1.3.6.1.4.1.35616.5.1.26.1.13Columnlt2sMgmtSfpTxPowerread-onlycurrentThe SFP transmit power of the port. If the SFP is removed, the value is -1.
1.3.6.1.4.1.35616.5.1.26.1.14Columnlt2sMgmtSfpRxPowerread-onlycurrentThe SFP receive power of the port. If the SFP is removed, the value is -1.
1.3.6.1.4.1.35616.5.1.26.1.15Columnlt2sMgmtSfpLaserTempread-onlycurrentThe internal temperature of the SFP. If the SFP is removed, the value is -1.
1.3.6.1.4.1.35616.5.1.26.1.16Columnlt2sMgmtSfpLaserBiasread-onlycurrentThe SFP laser bias in milli ampere. If the SFP is removed, the value is -1.
1.3.6.1.4.1.35616.5.1.26.1.17Columnlt2sMgmtSfpTxLowread-writecurrentThe SFP laser TX low threshold in dBm.
1.3.6.1.4.1.35616.5.1.26.1.18Columnlt2sMgmtSfpTxHighread-writecurrentThe SFP laser TX high threshold in dBm.
1.3.6.1.4.1.35616.5.1.26.1.19Columnlt2sMgmtSfpRxLowread-writecurrentThe SFP laser RX low threshold in dBm.
1.3.6.1.4.1.35616.5.1.26.1.20Columnlt2sMgmtSfpRxHighread-writecurrentThe SFP laser RX high threshold in dBm.
1.3.6.1.4.1.35616.5.2Nodelt2sSystem
1.3.6.1.4.1.35616.5.2.1Scalarlt2sTemperatureread-onlycurrentShows the ambient temperature.
1.3.6.1.4.1.35616.5.2.2Scalarlt2sPowerTyperead-onlycurrentThe device's power supply 1 type.
1.3.6.1.4.1.35616.5.2.3Scalarlt2sPowerStatusread-onlycurrentThe device's power supply 1 status.
1.3.6.1.4.1.35616.5.2.4Scalarlt2sPowerFanStatusread-onlycurrentThe device's power supply 1's fan status.
1.3.6.1.4.1.35616.5.2.5Scalarlt2sPowerFanRPMread-onlycurrentThe device's power supply 1's fan rounds per minute.
1.3.6.1.4.1.35616.5.2.6Scalarlt2sPowerFanModeread-writecurrentThe device's power supply 1's fan mode.
1.3.6.1.4.1.35616.5.2.7Scalarlt2sPowerFanOnTempread-writecurrentThe device's power supply 1's fan on temperature.
1.3.6.1.4.1.35616.5.2.8Scalarlt2sPowerFanOffTempread-writecurrentThe device's power supply 1's fan off temperature.
1.3.6.1.4.1.35616.5.3Nodelt2sPorts
1.3.6.1.4.1.35616.5.3.1Tablelt2sPortTablenot-accessiblecurrentA list of port table entries.
1.3.6.1.4.1.35616.5.3.1.1Rowlt2sPortEntrynot-accessiblecurrentAn entry containing information applicable to a particular port.
1.3.6.1.4.1.35616.5.3.1.1.1Columnlt2sPortIdread-onlycurrentA unique value for each port.
1.3.6.1.4.1.35616.5.3.1.1.2Columnlt2sPortEnableread-writecurrentThe status of the port.
1.3.6.1.4.1.35616.5.3.1.1.3Columnlt2sPortApsdread-writecurrentThe automatic power shut down configuration of the port.
1.3.6.1.4.1.35616.5.3.1.1.4Columnlt2sPortSpeedread-writecurrentThe speed mode of the port.
1.3.6.1.4.1.35616.5.3.1.1.5Columnlt2sPortResetread-writecurrentReset the port.
1.3.6.1.4.1.35616.5.3.1.1.6Columnlt2sPortLoopread-writecurrentSet Loop on chosen port.
1.3.6.1.4.1.35616.5.3.1.1.7Columnlt2sPortNameread-writecurrentThe name of the port.
1.3.6.1.4.1.35616.5.3.1.1.8Columnlt2sLinePluggedread-onlycurrentThe line SFP plugged state of the port.
1.3.6.1.4.1.35616.5.3.1.1.9Columnlt2sLineLinkread-onlycurrentThe line SFP link state of the port.
1.3.6.1.4.1.35616.5.3.1.1.10Columnlt2sLineApsdread-onlycurrentThe automatic power shut down state of the line port.
1.3.6.1.4.1.35616.5.3.1.1.11Columnlt2sLineTyperead-onlycurrentThe line SFP type of the port.
1.3.6.1.4.1.35616.5.3.1.1.12Columnlt2sLineWavelengthread-onlycurrentThe line SFP wavelength of the port. If the line SFP is not plugged in, the object should contain the value of 'NA'.
1.3.6.1.4.1.35616.5.3.1.1.13Columnlt2sLineTxPowerread-onlycurrentThe line SFP transmit power of the port. If the line SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.14Columnlt2sLineRxPowerread-onlycurrentThe line SFP receive power of the port. If the line SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.15Columnlt2sLineLaserTempread-onlycurrentThe line SFP laser temperature of the port. If the line SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.16Columnlt2sLineLaserBiasread-onlycurrentThe line SFP laser bias of the port. If the line SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.17Columnlt2sLineTxLowread-writecurrentThe line SFP laser TX low threshold of the port.
1.3.6.1.4.1.35616.5.3.1.1.18Columnlt2sLineTxHighread-writecurrentThe line SFP laser TX high threshold of the port.
1.3.6.1.4.1.35616.5.3.1.1.19Columnlt2sLineRxLowread-writecurrentThe line SFP laser RX low threshold of the port.
1.3.6.1.4.1.35616.5.3.1.1.20Columnlt2sLineRxHighread-writecurrentThe line SFP laser RX high threshold of the port.
1.3.6.1.4.1.35616.5.3.1.1.21Columnlt2sClientPluggedread-onlycurrentThe client SFP plugged state of the port.
1.3.6.1.4.1.35616.5.3.1.1.22Columnlt2sClientLinkread-onlycurrentThe client SFP link state of the port.
1.3.6.1.4.1.35616.5.3.1.1.23Columnlt2sClientApsdread-onlycurrentThe automatic power shut down state of the client port.
1.3.6.1.4.1.35616.5.3.1.1.24Columnlt2sClientTyperead-onlycurrentThe client SFP type of the port.
1.3.6.1.4.1.35616.5.3.1.1.25Columnlt2sClientWavelengthread-onlycurrentThe client SFP wavelength of the port. If the client SFP is not plugged in, the object should contain the value of 'NA'.
1.3.6.1.4.1.35616.5.3.1.1.26Columnlt2sClientTxPowerread-onlycurrentThe client SFP transmit power of the port. If the client SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.27Columnlt2sClientRxPowerread-onlycurrentThe client SFP receive power of the port. If the client SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.28Columnlt2sClientLaserTempread-onlycurrentThe client SFP laser temperature of the port. If the client SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.29Columnlt2sClientLaserBiasread-onlycurrentThe client SFP laser bias of the port. If the client SFP is not plugged in, the object should contain the value of -1.
1.3.6.1.4.1.35616.5.3.1.1.30Columnlt2sClientTxLowread-writecurrentThe client SFP laser TX low threshold of the port.
1.3.6.1.4.1.35616.5.3.1.1.31Columnlt2sClientTxHighread-writecurrentThe client SFP laser TX high threshold of the port.
1.3.6.1.4.1.35616.5.3.1.1.32Columnlt2sClientRxLowread-writecurrentThe client SFP laser RX low threshold of the port.
1.3.6.1.4.1.35616.5.3.1.1.33Columnlt2sClientRxHighread-writecurrentThe client SFP laser RX high threshold of the port.
1.3.6.1.4.1.35616.5.4Nodelt2sInfo
1.3.6.1.4.1.35616.5.4.1Scalarlt2sTrapDetailsread-onlycurrentThe trap description.
1.3.6.1.4.1.35616.5.8Nodelt2sCompliances
1.3.6.1.4.1.35616.5.8.1Compliancelt2sCompliancecurrentDescribes the requirements for conformance to the Lambdatrail2 MIB part.
1.3.6.1.4.1.35616.5.9Nodelt2sGroups
1.3.6.1.4.1.35616.5.9.1Grouplt2sAgentGroupcurrentGrouping all LT2-S Agent parameters.
1.3.6.1.4.1.35616.5.9.2Grouplt2sSystemGroupcurrentGrouping all LT2-S system parameters.
1.3.6.1.4.1.35616.5.9.3Grouplt2sPortsGroupcurrentGrouping all LT2-S port parameters.
1.3.6.1.4.1.35616.5.9.4Grouplt2sInfoGroupcurrentGrouping all LT2-S info parameters.
1.3.6.1.4.1.35616.5.9.5Grouplt2sNotificationGroupcurrentAll the Traps the Lambdatrail2-S supports.