LaserJet-Series8000-MIB
737 objects
No module-level DESCRIPTION found.
Imported Objects
| SNMPv2-SMI | enterprises |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.11 | Nodehp | |||
| 1.3.6.1.4.1.11.2 | Nodenm | |||
| 1.3.6.1.4.1.11.2.3 | Nodehpsystem | |||
| 1.3.6.1.4.1.11.2.3.9 | Nodenet-peripheral | |||
| 1.3.6.1.4.1.11.2.3.9.4 | Nodenetdm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2 | Nodedm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1 | Nodedevice | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1 | Nodesystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1 | Nodesettings-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.1 | Scalarenergy-star | read-write | optional | Returns or changes the Energy Star sleep value. If the value is greater than zero, then the device will go into energy saving sleep mode after the print engine… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2 | Scalarsleep-mode | read-write | optional | Returns eTrue if the device is in energy saving sleep mode, otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes the device to wake up, if it is in sl… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.21 | Scalarrun-location | read-write | optional | Returns or changes the location from which code executes. The object allows the user to pick a memory bank to run code from which is different than the default… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2 | Nodestatus-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.5 | Scalaron-off-line | read-write | optional | To bring the PDL processing sub-system on or off line. If the device is a printer, then the printer does not process print job data when the printer is off lin… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6 | Scalarcontinue | write-only | optional | A device can support a class of errors called continuable errors. When a continuable error is encountered, the device requires a continue event to occur before… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7 | Scalarauto-continue | read-write | optional | Indicates if the device will automatically continue after encountering a continuable error. If AUTO- CONTINUE is set to eOn, the device will automatically gene… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.35 | Scalarjob-input-auto-continue-timeout | read-write | optional | The number of seconds the device waits after a job related continuable error occurs before automatically continuing. An example job related continuable error i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.36 | Scalarjob-input-auto-continue-mode | read-write | optional | Returns or sets the device behavior when the desired media is not currently available. cCancelJob - The device cancels the job. The device POS should explain w… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37 | Nodebackground-message | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1 | Nodebackground-message1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1 | Scalarbackground-status-msg-line1-part1 | read-write | optional | The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2 | Nodebackground-message2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2.1 | Scalarbackground-status-msg-line2-part1 | read-write | optional | The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.38 | Scalarerror-log-clear | write-only | optional | Setting this object clears all the entries in the error log sub-tree. Additional information: Setting this object removes all errors that have been stored in t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.40 | Scalarjob-output-auto-continue-timeout | read-write | optional | Returns or sets the time that the printer will wait after an output bin becomes full and the printer is trying to deliver a sheet of media to that output bin. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.42 | Scalarcollated-originals-support | read-only | optional | Indicates that the printer can create multiple, collated 'originals' of a job and shows the level of support for this capability. cCollatedOriginals - The prin… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.52 | Scalarlocalization-languages-supported | read-only | optional | The list of languages supported by the device. The languages are primarily, but not limited to, two character codes from ISO 639, each separated by a comma cha… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.53 | Scalarlocalization-countries-supported | read-only | optional | The list of countries supported by the device. The countries are primarily, but not limited to, two character codes from ISO 3166, each separated by a comma ch… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3 | Nodeid | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.1 | Scalarmodel-number | read-only | optional | Identifies the device model number as listed in the HP corporate price list (e.g. C2121A for DeskJet 500C). The string is as specific as possible. Products sho… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.2 | Scalarmodel-name | read-only | optional | Identifies the device model name (e.g. ''DeskJet 1200C''). The string is as specific as possible. Capitalization and spacing should match family naming convent… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.3 | Scalarserial-number | read-only | optional | Identifies the serial number for the device. If the SERIAL-NUMBER object is set by the user, then setting the object does not need to be protected. If the SERI… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.10 | Scalardevice-name | read-write | optional | User defined device name. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.11 | Scalardevice-location | read-write | optional | User defined device location. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as muc… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12 | Scalarasset-number | read-write | optional | User defined asset number. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much a… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4 | Nodeinterface | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1 | Nodesimm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1 | Nodesimm1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.4 | Scalarsimm1-type | read-only | optional | Returns an indication of the type of option installed in SIMM slot 1. eEmpty means the device did not detect any option installed in the interface slot. eUnkno… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.5 | Scalarsimm1-capacity | read-only | optional | Returns an indication of the capacity of the SIMM installed in SIMM slot 1. The capacity is dependent on the type of option, as indicated by the SIMM1-TYPE obj… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6 | Nodesimm1-bank | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1 | Nodesimm1-bank1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1.1 | Scalarsimm1-bank1-type | read-only | optional | Returns an indication of the type of option installed in Bank 1 of SIMM slot 1. See SIMM1-TYPE for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1.2 | Scalarsimm1-bank1-capacity | read-only | optional | Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a description. Additional information: Returns an … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2 | Nodesimm1-bank2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2.1 | Scalarsimm1-bank2-type | read-only | optional | Returns an indication of the type of option installed in Bank 2 of SIMM slot 1. See SIMM1-TYPE for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2.2 | Scalarsimm1-bank2-capacity | read-only | optional | Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a description. Additional information: Returns an … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2 | Nodesimm2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.4 | Scalarsimm2-type | read-only | optional | Returns an indication of the type of option installed in SIMM slot 2. See SIMM1-TYPE for a description. Additional information: This object is used for describ… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.5 | Scalarsimm2-capacity | read-only | optional | Returns an indication of the capacity of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6 | Nodesimm2-bank | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1 | Nodesimm2-bank1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1.1 | Scalarsimm2-bank1-type | read-only | optional | Returns an indication of the type of option installed in Bank 1 of SIMM slot 2. See SIMM1-TYPE for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1.2 | Scalarsimm2-bank1-capacity | read-only | optional | Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: Returns an … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2 | Nodesimm2-bank2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2.1 | Scalarsimm2-bank2-type | read-only | optional | Returns an indication of the type of option installed in Bank 2 of SIMM slot 2. See SIMM1-TYPE for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2.2 | Scalarsimm2-bank2-capacity | read-only | optional | Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: Returns an … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3 | Nodesimm3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.4 | Scalarsimm3-type | read-only | optional | Returns an indication of the type of option installed in SIMM slot 3. See SIMM1-TYPE for a description. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.5 | Scalarsimm3-capacity | read-only | optional | Returns an indication of the capacity of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6 | Nodesimm3-bank | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1 | Nodesimm3-bank1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1.1 | Scalarsimm3-bank1-type | read-only | optional | Returns an indication of the type of option installed in Bank 1 of SIMM slot 3. See SIMM1-TYPE for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1.2 | Scalarsimm3-bank1-capacity | read-only | optional | Returns an indication of the capacity of Bank 1 of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: Returns an … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2 | Nodesimm3-bank2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2.1 | Scalarsimm3-bank2-type | read-only | optional | Returns an indication of the type of option installed in Bank 2 of SIMM slot 3. See SIMM1-TYPE for a description. Additional information: This object is used f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2.2 | Scalarsimm3-bank2-capacity | read-only | optional | Returns an indication of the capacity of Bank 2 of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: Returns an … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3 | Nodemio | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1 | Nodemio1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.2 | Scalarmio1-model-name | read-only | optional | Returns product information identifying the I/O card. Example: XXXX |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.3 | Scalarmio1-manufacturing-info | read-only | optional | Returns information describing the manufacture of the I/O card installed in MIO/EIO slot 1. May include serial number and firmware revision. Additional informa… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.4 | Scalarmio1-type | read-only | optional | Returns an indication of the type of option installed in MIO/EIO slot 1. See SIMM1-TYPE for an explanation of the enumerations. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2 | Nodemio2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.2 | Scalarmio2-model-name | read-only | optional | Returns product information identifying the I/O card. Example: XXXX |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.3 | Scalarmio2-manufacturing-info | read-only | optional | Returns information describing the manufacture of the I/O card installed in MIO/EIO slot 2. May include serial number and firmware revision. Additional informa… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.4 | Scalarmio2-type | read-only | optional | Returns an indication of the type of option installed in MIO/EIO slot 2. See SIMM1-TYPE for an explanation of the enumerations. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3 | Nodemio3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3.2 | Scalarmio3-model-name | read-only | optional | Returns product information identifying the I/O card. Example: XXXX |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3.3 | Scalarmio3-manufacturing-info | read-only | optional | Returns information describing the manufacture of the I/O card installed in MIO/EIO interface 3. May include serial number and firmware revision. Additional in… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3.4 | Scalarmio3-type | read-only | optional | Returns an indication of the type of option installed in MIO/EIO interface 3. See SIMM1-TYPE for an explanation of the enumerations. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5 | Nodephd | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1 | Nodephd1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.1 | Scalarphd1-model | read-only | optional | Returns product information identifying the PHD device. Example: XXXX |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.2 | Scalarphd1-manufacturing-info | read-only | optional | Returns information describing the manufacture of this particular PHD. May include serial number and firmware revision. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.3 | Scalarphd1-type | read-only | optional | Returns an indication of the type of option installed as PHD 1. See SIMM1-TYPE for an explanation of the enumerations. Additional information: Returns an indic… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.4 | Scalarphd1-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2 | Nodephd2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.1 | Scalarphd2-model | read-only | optional | Returns product information identifying PHD device 2. Additional information: If at least one (1) external paper handling device is attached to the printer, th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.2 | Scalarphd2-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 2. May include serial number and firmware revision. Additional information: If at least one (1) external … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.3 | Scalarphd2-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 2. See SIMM1-TYPE for an explanation of the enumerations. Additional information: If at … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.4 | Scalarphd2-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3 | Nodephd3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.1 | Scalarphd3-model | read-only | optional | Returns product information identifying PHD device 3. Additional information: If at least two (2) external paper handling devices are attached to the printer, … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.2 | Scalarphd3-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 3. May include serial number and firmware revision. Additional information: If at least two (2) external … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.3 | Scalarphd3-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 3. See SIMM1-TYPE for an explanation of the enumerations. Additional information: If at … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.4 | Scalarphd3-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4 | Nodephd4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.1 | Scalarphd4-model | read-only | optional | Returns product information identifying PHD device 4. Additional information: If at least three (3) external paper handling devices are attached to the printer… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.2 | Scalarphd4-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 4. May include serial number and firmware revision. Additional information: If at least three (3) externa… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.3 | Scalarphd4-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 4. See SIMM1-TYPE for an explanation of the enumerations. Additional information: If at … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.4 | Scalarphd4-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.5 | Nodephd5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.5.1 | Scalarphd5-model | read-only | optional | Returns product information identifying PHD device 3. Additional information: If at least four (4) external paper handling devices are attached to the printer,… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.5.2 | Scalarphd5-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 5. May include serial number and firmware revision. Additional information: If at least four (4) external… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.5.3 | Scalarphd5-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 5. See SIMM1-TYPE for an explanation of the enumerations. Additional information: If at … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.5.4 | Scalarphd5-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.6 | Nodephd6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.6.1 | Scalarphd6-model | read-only | optional | Returns product information identifying PHD device 6. Additional information: If at least five (5) external paper handling devices are attached to the printer,… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.6.2 | Scalarphd6-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 6. May include serial number and firmware revision. Additional information: If at least five (5) external… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.6.3 | Scalarphd6-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 6. See SIMM1-TYPE for an explanation of the enumerations. Additional information: If at … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.6.4 | Scalarphd6-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5 | Nodetest | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5.1 | Scalarself-test | read-write | optional | Writing this object allows a device self test to be started. Reading this object provides an indication what self-test is currently executing, if any. Actual s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5.2 | Scalarprint-internal-page | read-write | optional | Writing this object to a value other than eNotPrintingAnInternalPage causes the device to attempt to print an internally generated page. Reading this object pr… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6 | Nodejob | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1 | Nodesettings-job | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.1 | Scalarclearable-warning | read-write | optional | Returns or controls how the device will track clearable warnings. A clearable warning indicates a transient event in the device. The device will continue after… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.2 | Scalarcancel-job | write-only | optional | Cancels the print job whose ID matches the value written to the CANCEL-JOB object. The host first learns the job ID using the CURRENT-JOB-PARSING-ID command. I… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.3 | Scalarjob-info-change-id | read-only | optional | Returns the current value of an object in the job-info sub-tree whose value has changed. Define the object identifier for the object whose value has changed as… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2 | Nodeactive-print-jobs | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2.1 | Nodejob-being-parsed | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2.1.1 | Scalarcurrent-job-parsing-id | read-only | optional | Contains the printer assigned job identification for the job currently being processed by the processing PDL sub- system. The job ID is a monotonically increas… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5 | Nodejob-info | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.1 | Scalarjob-info-name1 | read-only | optional | Contains the first part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: The job name is the s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.2 | Scalarjob-info-name2 | read-only | optional | Contains the second part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: See job-info-name1. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.10 | Scalarjob-info-stage | read-only | optional | Indicates what printer sub-systems are currently processing this print job. The last OID field for this dynamic object contains the job ID. cSourceSubsystem - … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.11 | Scalarjob-info-io-source | read-only | optional | Indicates which I/O source, the print job was received over. The value maps to port numbering scheme supported in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.12 | Scalarjob-info-pages-processed | read-only | optional | Indicates the number of pages processed by the processing subsystem. If neither the cSourceSubsystem or the cProcessingSubsystem items are in the associated JO… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.13 | Scalarjob-info-pages-printed | read-only | optional | Indicates the number of pages printed by the destination subsystem. If non of the cSourceSubsystem, cProcessingSubsystem or cDestinationSubsystem items are in … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.14 | Scalarjob-info-size | read-only | optional | Indicates the number of bytes of data processed by the processing subsystem. If neither of the cSourceSubsystem or cProcessingSubsystem items are in the associ… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.15 | Scalarjob-info-state | read-only | optional | Indicates the state of the job. The last OID field for this dynamic object contains the job ID. eAborted - the print job was aborted. eWaitingForResources - th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.19 | Scalarjob-info-outcome | read-only | optional | Indicates if any warning or error conditions were encountered while processing the assoicated job. The last OID field for this dynamic object contains the job … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.20 | Scalarjob-info-outbins-used | read-only | optional | Indicates which output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional information: Th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.22 | Scalarjob-info-physical-outbins-used | read-only | optional | Indicates which physical output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional inform… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23 | Nodejob-info-attribute | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.1 | Scalarjob-info-attr-1 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. Attribute objects are saved sequentially, starting with 1, after the start of a job. If mor… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.2 | Scalarjob-info-attr-2 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.3 | Scalarjob-info-attr-3 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.4 | Scalarjob-info-attr-4 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.5 | Scalarjob-info-attr-5 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.6 | Scalarjob-info-attr-6 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.7 | Scalarjob-info-attr-7 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.8 | Scalarjob-info-attr-8 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.9 | Scalarjob-info-attr-9 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.10 | Scalarjob-info-attr-10 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.11 | Scalarjob-info-attr-11 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.12 | Scalarjob-info-attr-12 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.13 | Scalarjob-info-attr-13 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.14 | Scalarjob-info-attr-14 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.15 | Scalarjob-info-attr-15 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.16 | Scalarjob-info-attr-16 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.24 | Scalarjob-info-requested-originals | read-only | optional | The number of requested collated copies. The value was supplied with the job via PJL QTY variable, the PostScript Collate and NumCopies entries in the page dev… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.25 | Scalarjob-info-page-count-current-original | read-only | optional | The page number being printed within the current copy of a collated multi-copy job. This value changes when the job-info-pages-printed changes. The job-info-pa… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.26 | Scalarjob-info-pages-in-original | read-only | optional | Number of pages in a single copy of a collated multi- copy job. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.27 | Scalarjob-info-printed-originals | read-only | optional | Number of collated copies completely printed and delivered to the output bin at time of query. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10 | Nodefile-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.1 | Nodesettings-file-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.1.1 | Scalarfile-system-memory | read-only | optional | The amount of memory, in bytes, used by the file system to buffer file data. Additional information: Reports the amount of memory, in bytes, reserved for use b… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.1.2 | Scalarfile-system-max-open-files | read-write | optional | The number of open files allowed at one time. Opening a file when the maximum number of files are currently open will fail. Additional information: Indicates t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.1.3 | Scalarfile-system-test-return-code | write-only | optional | This test object that will not be supported in any released product. Setting this object allows the next file system call return code to be specified or to sim… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2 | Nodestatus-file-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.1 | Scalarfile-system-statistic-read-open | read-only | optional | The number of times the file system has received requests to open a file for reading. Opening a file for both reading and writing will cause this value to chan… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.2 | Scalarfile-system-statistic-write-open | read-only | optional | The number of times the file system has received requests to open a file for writing. Opening a file for both reading and writing will cause this value to chan… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.3 | Scalarfile-system-statistic-successful | read-only | optional | A counter indicating the number of file system requests that completed successfully. The POS should state if a power cycle causes the counter is be reset to ze… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.4 | Scalarfile-system-statistic-unsuccessful | read-only | optional | A counter indicating the number of file system requests that completed unsuccessfully. The POS should state if a power cycle causes the counter is be reset to … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.5 | Scalarfile-system-statistic-current-memory-usage | read-only | optional | A value indicating the number of bytes of RAM currently used by the file system firmware. Additional information: Reset to the factory default value after a po… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.6 | Scalarfile-system-statistic-max-memory-usage | read-only | optional | A value indicating the maximum number of bytes of RAM used by the file system firmware. The POS should state if the value is reset to zero after a power cycle.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3 | Nodefile-systems | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.2 | Nodefile-system2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.2.6 | Scalarfile-system2-initialize-volume | write-only | optional | Setting this object to eInitializing causes file system 2 to be initialized. Reading this object indicates if the file system is currently being initialized. A… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.3 | Nodefile-system3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.3.6 | Scalarfile-system3-initialize-volume | write-only | optional | Setting this object to eInitializing causes file system 3 to be initialized. Reading this object indicates if the file system is currently being initialized. A… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.4 | Nodefile-system4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.4.6 | Scalarfile-system4-initialize-volume | write-only | optional | Setting this object to eInitializing causes file system 4 to be initialized. Reading this object indicates if the file system is currently being initialized. A… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11 | Nodeerrorlog | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.1 | Nodeerror1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.1.1 | Scalarerror1-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 1 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.1.2 | Scalarerror1-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.2 | Nodeerror2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.2.1 | Scalarerror2-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 2 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.2.2 | Scalarerror2-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.3 | Nodeerror3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.3.1 | Scalarerror3-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 3 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.3.2 | Scalarerror3-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.4 | Nodeerror4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.4.1 | Scalarerror4-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 4 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.4.2 | Scalarerror4-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.5 | Nodeerror5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.5.1 | Scalarerror5-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 5 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.5.2 | Scalarerror5-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.6 | Nodeerror6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.6.1 | Scalarerror6-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 6 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.6.2 | Scalarerror6-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.7 | Nodeerror7 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.7.1 | Scalarerror7-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 7 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.7.2 | Scalarerror7-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.8 | Nodeerror8 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.8.1 | Scalarerror8-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 8 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.8.2 | Scalarerror8-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.9 | Nodeerror9 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.9.1 | Scalarerror9-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 9 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 197… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.9.2 | Scalarerror9-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.10 | Nodeerror10 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.10.1 | Scalarerror10-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 10 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.10.2 | Scalarerror10-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.11 | Nodeerror11 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.11.1 | Scalarerror11-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 11 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.11.2 | Scalarerror11-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.12 | Nodeerror12 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.12.1 | Scalarerror12-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 12 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.12.2 | Scalarerror12-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.13 | Nodeerror13 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.13.1 | Scalarerror13-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 13 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.13.2 | Scalarerror13-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.14 | Nodeerror14 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.14.1 | Scalarerror14-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 14 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.14.2 | Scalarerror14-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.15 | Nodeerror15 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.15.1 | Scalarerror15-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 15 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.15.2 | Scalarerror15-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.16 | Nodeerror16 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.16.1 | Scalarerror16-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 16 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.16.2 | Scalarerror16-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.17 | Nodeerror17 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.17.1 | Scalarerror17-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 17 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.17.2 | Scalarerror17-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.18 | Nodeerror18 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.18.1 | Scalarerror18-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 18 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.18.2 | Scalarerror18-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.19 | Nodeerror19 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.19.1 | Scalarerror19-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 19 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.19.2 | Scalarerror19-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.20 | Nodeerror20 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.20.1 | Scalarerror20-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 20 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.20.2 | Scalarerror20-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.21 | Nodeerror21 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.21.1 | Scalarerror21-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 21 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.21.2 | Scalarerror21-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.22 | Nodeerror22 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.22.1 | Scalarerror22-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 22 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.22.2 | Scalarerror22-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.23 | Nodeerror23 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.23.1 | Scalarerror23-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 23 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.23.2 | Scalarerror23-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.24 | Nodeerror24 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.24.1 | Scalarerror24-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 24 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.24.2 | Scalarerror24-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.25 | Nodeerror25 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.25.1 | Scalarerror25-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 25 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.25.2 | Scalarerror25-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.26 | Nodeerror26 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.26.1 | Scalarerror26-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 26 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.26.2 | Scalarerror26-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.27 | Nodeerror27 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.27.1 | Scalarerror27-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 27 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.27.2 | Scalarerror27-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.28 | Nodeerror28 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.28.1 | Scalarerror28-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 28 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.28.2 | Scalarerror28-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.29 | Nodeerror29 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.29.1 | Scalarerror29-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 29 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.29.2 | Scalarerror29-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.30 | Nodeerror30 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.30.1 | Scalarerror30-time-stamp | read-only | optional | Contains some sort of time stamp indicating when error 30 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 19… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.30.2 | Scalarerror30-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12 | Noderesource-manager | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12.3 | Nodemass-storage-resources | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12.3.1 | Scalarmass-storage-resource-change-counter | read-only | optional | A counter which changes when a mass storage based resource has been added or deleted. Additional information: The value of this counter changes each time the M… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12.3.2 | Scalarmass-storage-resource-changed | write-only | optional | Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE- COUNTER to be incremented. Additional information: Returns <noSuchName> status if attempting to access th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13 | Noderemote-procedure-call | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.1 | Nodesettings-rpc | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.1.1 | Scalarrpc-test-return-code | write-only | optional | This test object that will not be supported in any released product. Setting this object allows the next RPC call return code to be specified. The POS will spe… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.1.2 | Scalarrpc-bind-protocol-address | read-write | optional | Array of Berkeley sockets style protocol addresses used to bind RPC to a communications protocol family. Setting an instance of this array object to a zero len… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2 | Nodestatus-rpc | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2.1 | Scalarrpc-statistic-successful | read-only | optional | A counter indicating the number of RPC requests that completed successfully (reply_data stat is SUCCESS). The POS should state if a power cycle causes the coun… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2.2 | Scalarrpc-statistic-unsuccessful | read-only | optional | A counter indicating the number of RPC requests that completed unsuccessfully (reply_data stat is not SUCCESS). The POS should state if a power cycle causes th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2.3 | Scalarrpc-bound-protocol-address | read-only | optional | An array of Berkeley sockets style protocol addresses that the NFS service has been bound to successful. The format is that same as the array of RPC-BIND-PROTO… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3 | Noderpc-services | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2 | Nodenfs-server | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1 | Nodesettings-nfs-server | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1.1 | Scalarnfs-server-memory | read-only | optional | The amount of memory, in bytes, used by the Network File System server to buffer file data. Additional information: Reports the amount of memory, in bytes, res… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1.2 | Scalarnfs-server-read-size | read-write | optional | The maximum amount of data transferred in one NFS server read data call. Additional information: An unfortunate side effect of the implementation is initializi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1.3 | Scalarnfs-server-write-size | read-write | optional | The maximum amount of data transferred in one NFS server write data call. Additional information: An unfortunate side effect of the implementation is initializ… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1.4 | Scalarnfs-server-test-return-code | write-only | optional | This test object that will not be supported in any released product. Setting this object allows the next NFS call return code to be specified. The POS will spe… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2 | Nodestatus-nfs-server | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.1 | Scalarnfs-server-statistic-successful | read-only | optional | A counter indicating the number of NFS requests that completed without error. The POS should state if a power cycle causes the counter is be reset to zero. Add… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.2 | Scalarnfs-server-statistic-unsuccessful | read-only | optional | A counter indicating the number of NFS requests that completed with an NFS status other than NFS_OK (0). The POS should state if a power cycle causes the count… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.4 | Scalarnfs-server-statistic-current-memory-usage | read-only | optional | A value indicating the number of bytes of RAM currently used by the NFS firmware. Additional information: Reset to the factory default value after a power cycl… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.5 | Scalarnfs-server-statistic-max-memory-usage | read-only | optional | A value indicating the maximum number of bytes of RAM used by the NFS firmware. The POS should state if the value is reset to zero after a power cycle. Additio… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3 | Noderpc-bind | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.1 | Nodesettings-rpc-bind | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.1.1 | Scalarrpc-bind-test-return-code | write-only | optional | This test object that will not be supported in any released product. Setting this object allows the next RPC bind call return code to be specified. The POS wil… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.2 | Nodestatus-rpc-bind | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.2.1 | Scalarrpc-bind-statistic-successful | read-only | optional | A counter indicating the number of RPC bind (RPC program number 100000, version 2) requests that completed successfully. The POS should state if a power cycle … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.2.2 | Scalarrpc-bind-statistic-unsuccessful | read-only | optional | A counter indicating the number of RPC bind (RPC program number 100000, version 2) requests that completed unsuccessfully. The POS should state if a power cycl… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14 | Nodexport-interface | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14.2 | Nodestatus-xip | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14.2.1 | Scalarxip-statistic-processed | read-only | optional | A counter indicating the number of XIP requests that were processed. The POS should state if a power cycle causes the counter is be reset to zero. Additional i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14.2.2 | Scalarxip-statistic-data-in-dropped | read-only | optional | A counter indicating the number of XIP data in datagrams that were dropped (typically due to the printer being flooded with XIP requests ). The POS should stat… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15 | Nodemass-storage-block-driver | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.1 | Nodesettings-mass-storage-bd | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.1.1 | Scalarram-disk-mode | read-write | optional | Returns or controls RAM disk support. eOFF turns off the RAM disk functionality. eOn turns on the RAM disk functionality and creates a RAM disk whose size is c… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.1.2 | Scalarram-disk-size | read-write | optional | Returns or controls the size of the RAM disk. The device POS specifies the minimum memory requirements. The object MAXIMUM-RAM-DISK-MEMORY specifies the maximu… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.2 | Nodestatus-mass-storage-bd | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.2.1 | Scalarmaximum-ram-disk-memory | read-only | optional | This object's name is misleading. This object does not return the maximum configurable RAM disk size. Instead, it returns the maximum amount of memory, in byte… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2 | Nodesource-subsystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1 | Nodeio | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1 | Nodesettings-io | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.1 | Scalario-timeout | read-write | optional | The amount of time, in seconds, to wait for more print job data to be received before an I/O timeout occurs. The I/O channel being timed is the I/O channel tha… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.2 | Scalario-switch | read-only | optional | Indicates if the device will switch between I/O channels when a job boundary is encountered and print job data is available on another I/O channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.5 | Scalario-buffering | read-write | optional | Returns or controls the manner in which the device performs I/O data buffering. I/O data buffering allows additional print job data to be buffered by the I/O s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.6 | Scalario-buffer-size | read-write | optional | Returns or configures the amount of memory, in bytes, dedicated to I/O print job data buffering. Attempting to set to an unsupported value causes the device to… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.7 | Scalarmaximum-io-buffering-memory | read-only | optional | This object's name is misleading. Returns the maximum amount of additional memory, in bytes, that can be dedicated to buffering print job data. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3 | Nodeports | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3.1 | Nodeport1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3.1.4 | Scalarport1-parallel-speed | read-write | optional | Returns or changes the maximum parallel I/O port speed, for port 1. This object is only supported if this port is a parallel port. An eSlow setting causes a 10… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3.1.5 | Scalarport1-parallel-bidirectionality | read-write | optional | Returns or changes whether the parallel I/O port supports bidirectional communication for port 1. This object is only supported if this port is a parallel port… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.4 | Nodespooler | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.4.1 | Nodesettings-spooler | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.4.1.1 | Scalarmopy-mode | read-write | optional | Controls or reports how mopies are generated. eOff turns off the mopy feature. eAuto allows the device to determine the best method for generating mopies based… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3 | Nodeprocessing-subsystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3 | Nodepdl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1 | Nodesettings-pdl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.4 | Scalardefault-copies | read-write | optional | Returns or changes default copies. Default copies is the default values used by the PDL to control the number of copies of each page in the print job that are … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.5 | Scalarform-feed | write-only | optional | Instructs the PDL processing sub-system to finishing processing the current page of the current job. Form feed is also known as close page or eject page. If th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.6 | Scalarresource-saving | read-write | optional | Returns or changes PDL resource saving. Resource saving stores a PDL's permanent soft resources, like fonts, even when another PDL is active. Resource saving i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.7 | Scalarmaximum-resource-saving-memory | read-only | optional | This object's name is misleading. This object returns the maximum amount of additional memory, in bytes, that can be dedicated to holding PDL permanent soft re… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.8 | Scalardefault-vertical-black-resolution | read-write | optional | Returns or changes the value of the default vertical black resolution. The units are dots per inch. Additional information: In MoBY changing this OID also caus… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.9 | Scalardefault-horizontal-black-resolution | read-write | optional | Returns or changes the value of the default horizontal black resolution. The units are dots per inch. Additional information: In MoBY changing this object also… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.10 | Scalardefault-page-protect | read-write | optional | Returns or changes the default page protection behavior. If eOff, the device does not reserve memory for holding the entire raster form of a processed page. If… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.11 | Scalardefault-lines-per-page | read-write | optional | Returns or changes the default number of lines per page. The POS indicates the supported values. An unsupported value causes the printer to use the closest sup… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.12 | Scalardefault-vmi | read-write | optional | Returns or changes the default vertical motion index. The unit of measure for VMI is centipoints per line. The POS indicates the supported values. An unsupport… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.13 | Scalardefault-media-size | read-write | optional | This indicates the default media size. A write of an unsupported value causes an <badValue>. Complete list of supported media sizes along with their dimensions… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.19 | Scalarcold-reset-media-size | read-write | optional | Returns or sets the media size that is used as the DEFAULT-MEDIA-SIZE when a cold reset occurs. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.22 | Scalardefault-media-name | read-write | optional | Returns or sets the media name that is used until the media name is changed by a print job command. Additional information: This string must be one of the MEDI… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.39 | Scalardefault-bits-per-pixel | read-write | optional | Controls the number of levels used (per pixel) when printing grayscale or color images. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.2 | Nodestatus-pdl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.2.2 | Scalarform-feed-needed | read-only | optional | Indicates if the PDL processing sub-system has made marks on the current page and the source subsystem has been idle for a device specific amount of time. Addi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3 | Nodepdl-pcl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.2 | Scalarpcl-resource-saving-memory-size | read-write | optional | Returns or changes the amount of resource saving memory set aside to hold permanent soft PCL resources. Additional information: The value returned by this obje… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.5 | Scalarpcl-total-page-count | read-only | optional | Total number of PCL pages printed by the device. Additional information: In MoBY the PCL page count is kept in NVRAM, and the NVRAM value is updated at least e… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.13 | Scalarpcl-default-font-height | read-write | optional | Returns or changes the default PCL height. Height is an approximate measure of the body of the type in centipoints. A centipoint is 1/7200 inch. Height applies… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.14 | Scalarpcl-default-font-source | read-write | optional | Returns or changes the value of the default font source variable in NVRAM. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.15 | Scalarpcl-default-font-number | read-write | optional | Returns or changes the value of the default font number variable in NVRAM. Writing an unsupported value causes the printer to generate an <badValue>. Additiona… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.16 | Scalarpcl-default-font-width | read-write | optional | Returns or changes the default PCL font width. Width is expressed as the width of a character in centipoints. A centipoint is 1/7200 inch. Width applies only t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4 | Nodepdl-postscript | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.2 | Scalarpostscript-resource-saving-memory-size | read-write | optional | Returns or changes the amount of resource saving memory set aside to hold permanent soft PostScript resources. Additional information: The value returned by th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.5 | Scalarpostscript-total-page-count | read-only | optional | Total number of PostScript pages printed by the device. Additional information: This object is only supported if the PostScript option is installed. In MoBY th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.11 | Scalarpostscript-print-errors | read-write | optional | Returns or changes the value of the print PostScript errors setting. If eOn, PostScript prints an error page showing the error encountered and the stack at the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.5 | Nodepjl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.5.1 | Scalarpjl-password | read-only | optional | Returns PJL password, if the password is not set (zero). If the password is set, then attempting to retrieve the password causes an <genErr> to occur and will … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8 | Nodejetsend-proc-sub | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.1 | Nodesettings-jetsend | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.1.1 | Scalarjetsend-mode | read-write | mandatory | Enables or disables the JetSend processing sub-system. Additional information: Enables or disables the JetSend processing subsystem. The valid values are eOff … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3 | Nodejetsend-contact | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1 | Nodesettings-jetsend-contact | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1.1 | Scalarjetsend-contact-password | write-only | mandatory | A C structure containing the following fields: typedef struct { ubyte old_password[8]; ubyte new_password[8];/ } jetsend_change_contact_password_t; where ubyte… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1.2 | Scalarjetsend-contact-ip-address-security | write-only | mandatory | A C structure containing the following fields: typedef struct { ubyte reserved[3]; ubyte command; /* command: 0 to 1 */ ubyte password[8]; ubyte IPAddress[4]; … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4 | Nodedestination-subsystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1 | Nodeprint-engine | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1 | Nodesettings-prt-eng | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.2 | Scalaroverride-media-name | read-write | optional | Sets a string identifying the media name that is to be used in place of the currently requested media. The substitution will continue until another media is se… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.3 | Scalaroverride-media-size | read-write | optional | Sets the media size that is to be used in place of the currently requested media size. Additional information: When a request is received to print on a size an… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.5 | Scalarprint-density | read-write | optional | Returns or sets the print density setting. Print density is the instantaneous amount of marking agent applied to the paper while printing. A value of zero has … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.2 | Nodestatus-prt-eng | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.2.22 | Scalarduplex-page-count | read-only | optional | Total number of sheets of media that have been duplex printed. A sheet is counted if it travels through the duplex page path, regardless of whether or not mark… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3 | Nodeintray | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1 | Nodesettings-intray | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1.5 | Scalarmp-tray | read-write | optional | Returns or changes the value of the multi-purpose (MP) tray configuration variable. The MP tray can be configured to operate as an additional input tray (eCass… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1.7 | Scalarcustom-paper-dim-unit | read-write | optional | The units of measure used to specify the width and height of the printer's custom paper. The unit of measure of eTenThousandthsOfInches is 0.0001 inches. Addit… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1.8 | Scalarcustom-paper-feed-dim | read-write | optional | Sets the printer's custom paper dimension in the feed direction (direction parallel to the direction of paper feeding). The value for this object is specified … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1.9 | Scalarcustom-paper-xfeed-dim | read-write | optional | Sets the printer's custom paper dimension in the cross- feed direction (direction ninety degrees relative to the direction of paper feeding). The value for thi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3 | Nodeintrays | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.1 | Nodeintray1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.1.1 | Scalartray1-media-size-loaded | read-write | optional | Returns the media size that is currently configuredconfigured in tray #1. This object can be set to indicate the media size currently loaded, if the printer su… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.1.12 | Scalartray1-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this input tray. Additional information: The internal trays belong to device 0, which is the bas… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.2 | Nodeintray2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.2.1 | Scalartray2-media-size-loaded | read-only | optional | Returns the media size that is currently configured in tray #2. Complete list of supported media sizes along with their dimensions are listed in the ''Media Si… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.2.12 | Scalartray2-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this input tray. Additional information: The internal trays belong to device 0 (base engine), th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.3 | Nodeintray3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.3.1 | Scalartray3-media-size-loaded | read-only | optional | Returns the media size that is currently configured in tray #3. Complete list of supported media sizes along with their dimensions are listed in the ''Media Si… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.3.12 | Scalartray3-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this input tray. Additional information: The internal trays belong to device 0 (base engine), th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.4 | Nodeintray4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.4.12 | Scalartray4-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this input tray. Additional information: The internal trays belong to device 0 (base engine), th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4 | Nodeoutbin | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.1 | Nodesettings-outbin | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.1.4 | Scalaroverflow-bin | read-write | optional | Returns or sets the bin that will be used for additional sheets of media when the current bin is full and printing is allowed to continue. Additional informati… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3 | Nodeoutbins | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.1 | Nodeoutbin1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.1.9 | Scalaroutbin1-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.5 | Nodemarking-agent | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.5.1 | Nodesettings-marking-agent | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.5.1.3 | Scalarlow-marking-agent-processing | read-write | optional | Returns or changes how the device processes a low marking agent event. If eCont, then the device continues to print. If eStop, then the device stops until a co… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6 | Nodeimaging | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6.5 | Scalardefault-ret | read-write | optional | Returns or changes the Resolution Enhancement Technology setting. Devices that only support eOff and on should map all other values to on and always return the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6.7 | Scalardefault-print-quality | read-write | optional | Returns or sets the default print quality. A value of zero has the lowest print quality. A value of 100 has the highest print quality. Each POS should document… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7 | Nodeph | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3 | Nodeph-devices | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.2 | Nodeph2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.2.2 | Scalarphd2-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.2.4 | Scalarphd2-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: If at least one (1) ex… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.3 | Nodeph3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.3.2 | Scalarphd3-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.3.4 | Scalarphd3-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: If at least two (2) ex… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.4 | Nodeph4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.4.2 | Scalarphd4-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.4.4 | Scalarphd4-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: If at least three (3) … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.5 | Nodeph5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.5.2 | Scalarphd5-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.5.4 | Scalarphd5-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: If at least four (4) e… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.6 | Nodeph6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.6.2 | Scalarphd6-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.6.4 | Scalarphd6-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: If at least five (5) e… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8 | Nodeprint-media | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.1 | Nodesettings-print-media | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.1.1 | Scalarmedia-names-available | read-write | optional | The value of this object controls which of the MEDIAx- NAME objects are supported. If a bit is set to zero, then attempting to get or set the corresponding MED… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.1.2 | Scalarnorth-edge-offset | read-write | optional | Returns or sets the number of 300 dpi dots by which the image is shifted. Shift is relative to the leading edge of the medium as the medium flows through the m… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3 | Nodemedia-info | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1 | Nodemedia1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1.1 | Scalarmedia1-name | read-only | optional | Media 1 name. Additional information: The symbol set for this string is Roman-8. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1.2 | Scalarmedia1-short-name | read-only | optional | Length restricted version of the media name 1. The length restriction is required to allow the media name to be displayed on the device's control panel. The de… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1.3 | Scalarmedia1-page-count | read-only | optional | Number of sheets of media 1 that have been printed. The device POS should state whether this value is lost across a power cycle or kept in NVRAM. Additional in… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1.4 | Scalarmedia1-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: The eng… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2 | Nodemedia2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2.1 | Scalarmedia2-name | read-only | optional | Media 2 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2.2 | Scalarmedia2-short-name | read-only | optional | Length restricted version of the media name 2. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2.3 | Scalarmedia2-page-count | read-only | optional | Number of sheets of media 2 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2.4 | Scalarmedia2-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3 | Nodemedia3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3.1 | Scalarmedia3-name | read-only | optional | Media 3 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3.2 | Scalarmedia3-short-name | read-only | optional | Length restricted version of the media name 3. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3.3 | Scalarmedia3-page-count | read-only | optional | Number of sheets of media 3 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3.4 | Scalarmedia3-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4 | Nodemedia4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4.1 | Scalarmedia4-name | read-only | optional | Media 4 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4.2 | Scalarmedia4-short-name | read-only | optional | Length restricted version of the media name 4. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4.3 | Scalarmedia4-page-count | read-only | optional | Number of sheets of media 4 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4.4 | Scalarmedia4-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5 | Nodemedia5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5.1 | Scalarmedia5-name | read-only | optional | Media 5 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5.2 | Scalarmedia5-short-name | read-only | optional | Length restricted version of the media name 5. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5.3 | Scalarmedia5-page-count | read-only | optional | Number of sheets of media 5 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5.4 | Scalarmedia5-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6 | Nodemedia6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6.1 | Scalarmedia6-name | read-only | optional | Media 6 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6.2 | Scalarmedia6-short-name | read-only | optional | Length restricted version of the media name 6. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6.3 | Scalarmedia6-page-count | read-only | optional | Number of sheets of media 6 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6.4 | Scalarmedia6-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7 | Nodemedia7 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7.1 | Scalarmedia7-name | read-only | optional | Media 7 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7.2 | Scalarmedia7-short-name | read-only | optional | Length restricted version of the media name 7. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7.3 | Scalarmedia7-page-count | read-only | optional | Number of sheets of media 7 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7.4 | Scalarmedia7-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8 | Nodemedia8 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8.1 | Scalarmedia8-name | read-only | optional | Media 8 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8.2 | Scalarmedia8-short-name | read-only | optional | Length restricted version of the media name 8. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8.3 | Scalarmedia8-page-count | read-only | optional | Number of sheets of media 8 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8.4 | Scalarmedia8-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9 | Nodemedia9 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9.1 | Scalarmedia9-name | read-only | optional | Media 9 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9.2 | Scalarmedia9-short-name | read-only | optional | Length restricted version of the media name 9. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9.3 | Scalarmedia9-page-count | read-only | optional | Number of sheets of media 9 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9.4 | Scalarmedia9-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10 | Nodemedia10 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10.1 | Scalarmedia10-name | read-only | optional | Media 10 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10.2 | Scalarmedia10-short-name | read-only | optional | Length restricted version of the media name 10. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10.3 | Scalarmedia10-page-count | read-only | optional | Number of sheets of media 10 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10.4 | Scalarmedia10-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11 | Nodemedia11 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11.1 | Scalarmedia11-name | read-only | optional | Media 11 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11.2 | Scalarmedia11-short-name | read-only | optional | Length restricted version of the media name 11. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA1-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11.3 | Scalarmedia11-page-count | read-only | optional | Number of sheets of media 11 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11.4 | Scalarmedia11-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13 | Nodemedia13 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13.1 | Scalarmedia13-name | read-write | optional | Media 13 name. Additional information: The maximum supported string length is 24 bytes. If the user entered string is too long, the device will store the first… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13.2 | Scalarmedia13-short-name | read-write | optional | Length restricted version of the media name 13. See MEDIA1-SHORT-NAME for details. Additional information: The maximum supported string length is 9 characters.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13.3 | Scalarmedia13-page-count | read-only | optional | Number of sheets of media 13 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13.4 | Scalarmedia13-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14 | Nodemedia14 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14.1 | Scalarmedia14-name | read-write | optional | Media 14 name. Additional information: See MEDIA13-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14.2 | Scalarmedia14-short-name | read-write | optional | Length restricted version of the media name 14. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA13-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14.3 | Scalarmedia14-page-count | read-only | optional | Number of sheets of media 14 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA13-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14.4 | Scalarmedia14-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15 | Nodemedia15 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15.1 | Scalarmedia15-name | read-write | optional | Media 15 name. Additional information: See MEDIA13-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15.2 | Scalarmedia15-short-name | read-write | optional | Length restricted version of the media name 15. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA13-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15.3 | Scalarmedia15-page-count | read-only | optional | Number of sheets of media 15 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA13-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15.4 | Scalarmedia15-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.16 | Nodemedia16 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.16.1 | Scalarmedia16-name | read-write | optional | Media 16 name. Additional information: See MEDIA13-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.16.2 | Scalarmedia16-short-name | read-write | optional | Length restricted version of the media name 16. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA13-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.16.3 | Scalarmedia16-page-count | read-only | optional | Number of sheets of media 16 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA13-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.16.4 | Scalarmedia16-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.17 | Nodemedia17 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.17.1 | Scalarmedia17-name | read-write | optional | Media 17 name. Additional information: See MEDIA13-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.17.2 | Scalarmedia17-short-name | read-write | optional | Length restricted version of the media name 17. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA13-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.17.3 | Scalarmedia17-page-count | read-only | optional | Number of sheets of media 17 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA13-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.17.4 | Scalarmedia17-engine-media-mode | read-write | optional | The engine processing characteristics that are to be applied to this media. The processing characteristics are device specific. Additional information: See the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.4 | Nodemedia-modes | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.4.1 | Scalarengine-media-modes-supported1 | read-only | optional | The list of engine media modes supported by the device. The modes are each separated by a comma character. An example string would be: 'Normal,Rough,Low,Vellum… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.5 | Nodemedia-size | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.5.2 | Scalarmedia-size-west-edge-first-side-offset | read-write | optional | Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). The adjustment is for… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.5.3 | Scalarmedia-size-west-edge-second-side-offset | read-write | optional | Returns or sets the number of 300 dpi dots by which the image is shifted relative to the west edge of the medium (see NORTH-EDGE-OFFSET). The adjustment is for… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7 | Nodetables | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2 | Nodechannel-table | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1 | Nodechannel-entry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.2 | Scalarchannel-bytes-sent | read-only | optional | The low order 31 bits of the number of bytes sent from the printer to the host on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.3 | Scalarchannel-bytes-received | read-only | optional | The low order 31 bits of the number of bytes received by the printer from the host on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.4 | Scalarchannel-io-errors | read-only | optional | The low order 31 bits of the number of I/O errors which have occured on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.5 | Scalarchannel-jobs-received | read-only | optional | The low order 31 bits of the number of print jobs which have been received on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.6 | Scalarchannel-mio | read-only | optional | The number of the MIO card associated with this logical channel. If this logical channel is not associated with an MIO card a zero is returned. The value retur… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2 | Nodeprintmib | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5 | NodeprtGeneral | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1 | NodeprtGeneralTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1 | NodeprtGeneralEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.1 | Scalarprtgeneralconfigchanges | read-only | optional | Counts configuration changes that change the capabilities of a printer, such as the addition/deletion of input/output bins, the addition/deletion of interprete… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.2 | Scalarprtgeneralcurrentlocalization | read-write | optional | The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identif… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.3 | Scalarprtgeneralreset | read-write | optional | Setting this value to `powerCycleReset', `resetToNVRAM', or `resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will a… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.4 | Scalarprtgeneralcurrentoperator | read-write | optional | The name of the person who is responsible for operating this printer. It is suggested that this string include information that would enable other humans to re… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.5 | Scalarprtgeneralserviceperson | read-write | optional | The name of the person responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.6 | Scalarprtinputdefaultindex | read-only | optional | The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. This value shall be -1 … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.7 | Scalarprtoutputdefaultindex | read-write | optional | The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination. This value shall be -1 i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.8 | Scalarprtmarkerdefaultindex | read-only | optional | The value of prtMarkerIndex corresponding to the default marker sub-unit; that is, this object selects the default marker. Refer to ftp://ftp.pwg.org/pub/pwg/p… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.9 | Scalarprtmediapathdefaultindex | read-write | optional | The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path. Refer to ftp://ftp.pwg.org/pub/pwg/pm… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.10 | Scalarprtconsolelocalization | read-write | optional | The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.11 | Scalarprtconsolenumberofdisplaylines | read-only | optional | The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display Refer t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.12 | Scalarprtconsolenumberofdisplaychars | read-only | optional | The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.13 | Scalarprtconsoledisable | read-write | optional | If the object prtConsoleDisable has value 'operatorConsoleDisabled' then input is not accepted from the operator console. If the object prtConsoleDisable has t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.14 | Scalarprtgeneralstartuppage | read-only | optional | Used to enable or disable printing a startup page. If enabled, a startup page will be printed shortly after power-up, when the device is ready. Typical startup… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.15 | Scalarprtgeneralbannerpage | read-only | optional | Used to enable or disable printing banner pages at the beginning of jobs. This is a master switch which applies to all jobs, regardless of interpreter. Refer t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.16 | Scalarprtgeneralprintername | read-write | optional | An administrator-specified name for this printer. Depending upon implementation of this printer, the value of this object may or may not be same as the value f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.17 | Scalarprtgeneralserialnumber | read-only | optional | A recorded serial number for this device that indexes some type device catalog or inventory. This value is usually set by the device manufacturer but the MIB s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.18 | Scalarprtalertcriticalevents | read-only | optional | A running counter of the number of critical alert events that have been recorded in the alert table. The value of this object is RESET in the event of a power … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.19 | Scalarprtalertallevents | read-only | optional | A running counter of the total number of alert event entries (critical and non-critical) that have been recorded in the alert table Refer to ftp://ftp.pwg.org/… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2 | NodeprtStorageRefTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2.1 | NodeprtStorageRefEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2.1.2 | Scalarprtstoragerefindex | read-only | optional | The value of the hrDeviceIndex of the printer device that this storageEntry is associated with. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3 | NodeprtDeviceRefTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3.1 | NodeprtDeviceRefEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3.1.2 | Scalarprtdevicerefindex | read-only | optional | The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6 | NodeprtCover | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1 | NodeprtCoverTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1 | NodeprtCoverEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1.2 | Scalarprtcoverdescription | read-only | optional | The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/draft… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1.3 | Scalarprtcoverstatus | read-only | optional | The status of this cover sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional info… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7 | NodeprtLocalization | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1 | NodeprtLocalizationTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1 | NodeprtLocalizationEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.2 | Scalarprtlocalizationlanguage | read-only | optional | A two character language code from ISO 639. Examples en, gb, ca, fr, de. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.3 | Scalarprtlocalizationcountry | read-only | optional | A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ... Ref… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.4 | Scalarprtlocalizationcharacterset | read-only | optional | The coded character set used for this localization. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8 | NodeprtInput | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2 | NodeprtInputTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1 | NodeprtInputEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.2 | Scalarprtinputtype | read-only | optional | The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.3 | Scalarprtinputdimunit | read-only | optional | The unit of measurement for use calculating and relaying dimensional values for this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.4 | Scalarprtinputmediadimfeeddirdeclared | read-write | optional | This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. Th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.5 | Scalarprtinputmediadimxfeeddirdeclared | read-write | optional | This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-un… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.6 | Scalarprtinputmediadimfeeddirchosen | read-only | optional | The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.7 | Scalarprtinputmediadimxfeeddirchosen | read-only | optional | The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.8 | Scalarprtinputcapacityunit | read-only | optional | The unit of measurement for use in calculating and relaying capacity values for this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.9 | Scalarprtinputmaxcapacity | read-only | optional | The maximum capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so thi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.10 | Scalarprtinputcurrentlevel | read-only | optional | The current capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). If this input sub-unit can reliably sense this value, the valu… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.11 | Scalarprtinputstatus | read-only | optional | The current status of this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additio… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.12 | Scalarprtinputmedianame | read-write | optional | A description of the media contained in this input sub-unit; This description is intended for display to a human operator. This description is not processed by… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.13 | Scalarprtinputname | read-only | optional | The name assigned to this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Addition… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.14 | Scalarprtinputvendorname | read-only | optional | The vendor name of this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.15 | Scalarprtinputmodel | read-only | optional | The model name of this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.16 | Scalarprtinputversion | read-only | optional | The version of this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.17 | Scalarprtinputserialnumber | read-only | optional | The serial number assigned to this input sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.18 | Scalarprtinputdescription | read-only | optional | A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/draf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.19 | Scalarprtinputsecurity | read-only | optional | Indicates if this input sub-unit has some security associated with it. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the S… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.24 | Scalarprtinputmedialoadtimeout | read-only | optional | When the printer is not able to print due to a subunit being empty or the requested media must be manually loaded, the printer will wait for the duration (in s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.26 | Scalarprtinputnextindex | read-only | optional | The value of prtInputIndex corresponding to the input subunit which will be used when this input subunit is emptied and the timeout specified by prtInputMediaL… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9 | NodeprtOutput | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2 | NodeprtOutputTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1 | NodeprtOutputEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.2 | Scalarprtoutputtype | read-only | optional | The type of technology supported by this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Print… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.3 | Scalarprtoutputcapacityunit | read-only | optional | The unit of measurement for use in calculating and relaying capacity values for this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.4 | Scalarprtoutputmaxcapacity | read-only | optional | The maximum capacity of this output sub-unit in output sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5 | Scalarprtoutputremainingcapacity | read-only | optional | The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (PrtCapacityUnitTC) of this output sub-unit. If this output s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.6 | Scalarprtoutputstatus | read-only | optional | The current status of this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.7 | Scalarprtoutputname | read-only | optional | The name assigned to this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additio… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.8 | Scalarprtoutputvendorname | read-only | optional | The vendor name of this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additiona… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.9 | Scalarprtoutputmodel | read-only | optional | The name assigned to this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.10 | Scalarprtoutputversion | read-only | optional | The version of this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional in… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.11 | Scalarprtoutputserialnumber | read-only | optional | The serial number assigned to this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.12 | Scalarprtoutputdescription | read-only | optional | A free-form text description of this output sub-unit in the localization specified by prtGeneralCurrentLocalization. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/dra… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.13 | Scalarprtoutputsecurity | read-only | optional | Indicates if this output sub-unit has some security associated with it and if that security is enabled or not. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pm… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.14 | Scalarprtoutputdimunit | read-only | optional | The unit of measurement for use in calculating and relaying dimensional values for this output sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.15 | Scalarprtoutputmaxdimfeeddir | read-only | optional | The maximum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.16 | Scalarprtoutputmaxdimxfeeddir | read-only | optional | The maximum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.17 | Scalarprtoutputmindimfeeddir | read-only | optional | The minimum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.18 | Scalarprtoutputmindimxfeeddir | read-only | optional | The minimum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.19 | Scalarprtoutputstackingorder | read-only | optional | The current state of the stacking order for the associated output sub-unit. `FirstToLast' means that as pages are output the front of the next page is placed a… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.20 | Scalarprtoutputpagedeliveryorientation | read-only | optional | The reading surface that will be `up' when pages are delivered to the associated output sub-unit. Values are faceUp and faceDown. (Note: interpretation of thes… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.21 | Scalarprtoutputbursting | read-only | optional | This object indicates that the outputting sub-unit supports bursting, and if so, whether the feature is enabled. Bursting is the process by which continuous me… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.22 | Scalarprtoutputdecollating | read-only | optional | This object indicates that the output supports supports decollating, and if so, whether the feature is enabled. Decollating is the process by which the individ… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.23 | Scalarprtoutputpagecollated | read-only | optional | This object indicates that the output sub-unit supports page collation, and if so, whether the feature is enabled. See glossary for definition of how this docu… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.24 | Scalarprtoutputoffsetstacking | read-only | optional | This object indicates that the output supports supports offset stacking, and if so, whether the feature is enabled. See glossary for how Offset Stacking is def… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10 | NodeprtMarker | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2 | NodeprtMarkerTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1 | NodeprtMarkerEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.2 | Scalarprtmarkermarktech | read-only | optional | The type of marking technology used for this marking sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.3 | Scalarprtmarkercounterunit | read-only | optional | The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.4 | Scalarprtmarkerlifecount | read-only | optional | The count of the number of units of measure counted during the life of printer using units of measure as specified by prtMarkerCounterUnit. Refer to ftp://ftp.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.5 | Scalarprtmarkerpoweroncount | read-only | optional | The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by prtMarkerCounterUni… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.6 | Scalarprtmarkerprocesscolorants | read-only | optional | The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and prtMarkerSpotColorants cannot both… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.7 | Scalarprtmarkerspotcolorants | read-only | optional | The number of spot colors supported by this marker. The value of this object and prtMarkerProcessColorants cannot both be 0. Must be 0 or greater. Refer to ftp… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.8 | Scalarprtmarkeraddressabilityunit | read-only | optional | The unit of measure of distances, as applied to the marker's resolution. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.9 | Scalarprtmarkeraddressabilityfeeddir | read-only | optional | The maximum number of addressable marking positions in the feed direction per 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.10 | Scalarprtmarkeraddressabilityxfeeddir | read-only | optional | The maximum number of addressable marking positions in the cross feed direction in 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.11 | Scalarprtmarkernorthmargin | read-only | optional | The margin, in units identified by prtMarkerAddressabilityUnit, from the leading edge of the medium as the medium flows through the marking engine with the sid… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.12 | Scalarprtmarkersouthmargin | read-only | optional | The margin from the South edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.13 | Scalarprtmarkerwestmargin | read-only | optional | The margin from the West edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.14 | Scalarprtmarkereastmargin | read-only | optional | The margin from the East edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.15 | Scalarprtmarkerstatus | read-only | optional | The current status of this marker sub-unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11 | NodeprtMarkerSupplies | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1 | NodeprtMarkerSuppliesTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1 | NodeprtMarkerSuppliesEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.2 | Scalarprtmarkersuppliesmarkerindex | read-only | optional | The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.3 | Scalarprtmarkersuppliescolorantindex | read-only | optional | The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no co… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.4 | Scalarprtmarkersuppliesclass | read-only | optional | Indicates whether this supply entity represents a supply that is consumed or a receptacle that is filled. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_03… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.5 | Scalarprtmarkersuppliestype | read-only | optional | The type of this supply. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional information: e… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.6 | Scalarprtmarkersuppliesdescription | read-only | optional | The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/draf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.7 | Scalarprtmarkersuppliessupplyunit | read-only | optional | Unit of measure of this marker supply container/receptacle. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Pri… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.8 | Scalarprtmarkersuppliesmaxcapacity | read-only | optional | The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit. If this supply container/receptacle can reliably sense this … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.9 | Scalarprtmarkersupplieslevel | read-only | optional | The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense thi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13 | NodeprtMediaPath | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4 | NodeprtMediaPathTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1 | NodeprtMediaPathEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.2 | Scalarprtmediapathmaxspeedprintunit | read-only | optional | The unit of measure used in specifying the speed of all media paths in the printer. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more det… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.3 | Scalarprtmediapathmediasizeunit | read-only | optional | The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer. Refer to ftp://ftp.pwg.org/pub/pw… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.4 | Scalarprtmediapathmaxspeed | read-only | optional | The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.5 | Scalarprtmediapathmaxmediafeeddir | read-only | optional | The maximum physical media size in the feed direction of this media path expressed in units of measure specified by PrtMediaPathMediaSizeUnit. A value of (-1) … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.6 | Scalarprtmediapathmaxmediaxfeeddir | read-only | optional | The maximum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.7 | Scalarprtmediapathminmediafeeddir | read-only | optional | The minimum physical media size in the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.8 | Scalarprtmediapathminmediaxfeeddir | read-only | optional | The minimum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.9 | Scalarprtmediapathtype | read-only | optional | The type of the media path for this media path. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Ad… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.10 | Scalarprtmediapathdescription | read-only | optional | The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization. Refer to ftp://ftp.pwg.org/pub/pwg/pmp… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.11 | Scalarprtmediapathstatus | read-only | optional | The current status of this media path. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14 | NodeprtChannel | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1 | NodeprtChannelTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1 | NodeprtChannelEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.2 | Scalarprtchanneltype | read-only | optional | The type of this print data channel. This object provides the linkage to ChannelType-specific groups that may (conceptually) extend the prtChannelTable with ad… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.3 | Scalarprtchannelprotocolversion | read-only | optional | The version of the protocol used on this channel. The format used for version numbering depends on prtChannelType. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/draft… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.4 | Scalarprtchannelcurrentjobcntllangindex | read-only | optional | The value of prtInterpreterIndex corresponding to the Control Language Interpreter for this channel. This interpreter defines the syntax used for control funct… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.5 | Scalarprtchanneldefaultpagedesclangindex | read-write | optional | The value of prtInterpreterIndex corresponding to the Page Description Language Interpreter for this channel. This interpreter defines the default Page Descrip… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.6 | Scalarprtchannelstate | read-only | optional | The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not. Refer to ftp://ft… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.7 | Scalarprtchannelifindex | read-only | optional | The value of ifIndex (in the ifTable; see the interface section of MIB-2/RFC 1213) which corresponds to this channel. When more than one row of the ifTable is … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.8 | Scalarprtchannelstatus | read-only | optional | The current status of the channel. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional info… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.9 | Scalarprtchannelinformation | read-only | optional | Auxiliary information to allow a printing application to use the channel for data submission to the printer. An application capable of using a specific PrtChan… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15 | NodeprtInterpreter | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1 | NodeprtInterpreterTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1 | NodeprtInterpreterEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.2 | Scalarprtinterpreterlangfamily | read-only | optional | The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate. Refer to ftp://ftp.pwg… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.3 | Scalarprtinterpreterlanglevel | read-only | optional | The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.4 | Scalarprtinterpreterlangversion | read-only | optional | The date code or version of the language which this interpreter is interpreting or emulating. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, fo… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.5 | Scalarprtinterpreterdescription | read-only | optional | A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.6 | Scalarprtinterpreterversion | read-only | optional | The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.7 | Scalarprtinterpreterdefaultorientation | read-write | optional | The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream). Refer to… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.8 | Scalarprtinterpreterfeedaddressability | read-only | optional | The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityFeedDir ) for this interpreter. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.9 | Scalarprtinterpreterxfeedaddressability | read-only | optional | The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityXFeedDir) for this interpr… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.10 | Scalarprtinterpreterdefaultcharsetin | read-write | optional | The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the oct… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.11 | Scalarprtinterpreterdefaultcharsetout | read-only | optional | The default character set for data coming from this interpreter through the printer's output channel (i.e. the 'backchannel'). This value shall be (2) if there… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.12 | Scalarprtinterpretertwoway | read-only | optional | Indicates whether or not this interpreter returns information back to the host. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16 | NodeprtConsoleDisplayBuffer | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5 | NodeprtConsoleDisplayBufferTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5.1 | NodeprtConsoleDisplayBufferEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5.1.2 | Scalarprtconsoledisplaybuffertext | read-only | optional | The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to on… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17 | NodeprtConsoleLights | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6 | NodeprtConsoleLightTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1 | NodeprtConsoleLightEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.2 | Scalarprtconsoleontime | read-only | optional | This object, in conjunction with prtConsoleOffTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the l… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.3 | Scalarprtconsoleofftime | read-only | optional | This object, in conjunction with prtConsoleOnTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the la… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.4 | Scalarprtconsolecolor | read-only | optional | The color of this light. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.5 | Scalarprtconsoledescription | read-only | optional | The vendor description or label of this light in the localization specified by prtConsoleLocalization. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_03169… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18 | NodeprtAlert | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1 | NodeprtAlertTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1 | NodeprtAlertEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.2 | Scalarprtalertseveritylevel | read-only | optional | The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table. Refer to ftp://ftp.pwg.org/pu… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.3 | Scalarprtalerttraininglevel | read-only | optional | See textual convention PrtAlertTrainingLevelTC Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Add… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.4 | Scalarprtalertgroup | read-only | optional | The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of ty… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.5 | Scalarprtalertgroupindex | read-only | optional | An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the printer that caused this alert. The… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.6 | Scalarprtalertlocation | read-only | optional | The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.7 | Scalarprtalertcode | read-only | optional | See associated textual convention PrtAlertCodeTC Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.8 | Scalarprtalertdescription | read-only | optional | A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by the printer to further elabora… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.9 | Scalarprtalerttime | read-only | optional | The value of sysUpTime at the time that this alert was generated. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standa… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3 | Nodehrm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2 | NodehrStorage | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.2 | Scalarhrmemorysize | read-only | mandatory | The amount of physical main memory contained by the host. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Addi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3 | NodehrStorageTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1 | NodehrStorageEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.1 | Scalarhrstorageindex | read-only | mandatory | A unique value for each logical storage area contained by the host. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more det… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.2 | Scalarhrstoragetype | read-only | mandatory | The type of storage represented by this entry. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additional info… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.3 | Scalarhrstoragedescr | read-only | mandatory | A description of the type and instance of the storage described by this entry. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.4 | Scalarhrstorageallocationunits | read-only | mandatory | The size, in bytes, of the data objects allocated from this pool. If this entry is monitoring sectors, blocks, buffers, or packets, for example, this number wi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.5 | Scalarhrstoragesize | read-only | mandatory | The size of the storage represented by this entry, in units of hrStorageAllocationUnits. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.6 | Scalarhrstorageused | read-only | mandatory | The amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits. Refer to RFC 1514, Host Resources MIB, http://ds.i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.7 | Scalarhrstorageallocationfailures | read-only | mandatory | The number of requests for storage represented by this entry that could not be honored due to not enough storage. It should be noted that as this object has a … |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3 | NodehrDevice | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2 | NodehrDeviceTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1 | NodehrDeviceEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.1 | Scalarhrdeviceindex | read-only | mandatory | A unique value for each device contained by the host. The value for each device must remain constant at least from one re-initialization of the agent to the ne… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.2 | Scalarhrdevicetype | read-only | mandatory | An indication of the type of device. If this value is `hrDeviceProcessor { hrDeviceTypes 3 }' then an entry exists in the hrProcessorTable which corresponds to… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.3 | Scalarhrdevicedescr | read-only | mandatory | A textual description of this device, including the device's manufacturer and revision, and optionally, its serial number. Refer to RFC 1514, Host Resources MI… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.4 | Scalarhrdeviceid | read-only | mandatory | The product ID for this device. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additional information (printe… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.5 | Scalarhrdevicestatus | read-only | mandatory | The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current state of the device is unknown. r… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6 | Scalarhrdeviceerrors | read-only | mandatory | The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. Ho… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5 | NodehrPrinterTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1 | NodehrPrinterEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1.1 | Scalarhrprinterstatus | read-only | mandatory | The current status of this printer device. When in the idle(1), printing(2), or warmup(3) state, the corresponding hrDeviceStatus should be running(2) or warni… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1.2 | Scalarhrprinterdetectederrorstate | read-only | mandatory | This object represents any error conditions detected by the printer. The error conditions are encoded as bits in an octet string, with the following definition… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.6 | NodehrDiskStorageTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.6.1 | NodehrDiskStorageEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.6.1.1 | Scalarhrdiskstorageaccess | read-write | mandatory | An indication if this long-term storage device is readable and writable or only readable. This should reflect the media type, any write-protect mechanism, and … |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.6.1.2 | Scalarhrdiskstoragemedia | read-only | mandatory | An indication of the type of media used in this long-term storage device. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for mo… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.6.1.3 | Scalarhrdiskstorageremoveble | read-only | mandatory | Denotes whether or not the disk media may be removed from the drive. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more de… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.6.1.4 | Scalarhrdiskstoragecapacity | read-only | mandatory | The total size for this long-term storage device. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additional i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.7 | NodehrPartitionTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.7.1 | NodehrPartitionEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.7.1.1 | Scalarhrpartitionindex | read-only | mandatory | A unique value for each partition on this long- term storage device. The value for each long-term storage device must remain constant at least from one re-init… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.7.1.2 | Scalarhrpartitionlabel | read-write | mandatory | A textual description of this partition. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additional informatio… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.7.1.3 | Scalarhrpartitionid | read-only | mandatory | A descriptor which uniquely represents this partition to the responsible operating system. On some systems, this might take on a binary representation. Refer t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.7.1.4 | Scalarhrpartitionsize | read-only | mandatory | The size of this partition. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additional information: The capaci… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.7.1.5 | Scalarhrpartitionfsindex | read-only | mandatory | The index of the file system mounted on this partition. If no file system is mounted on this partition, then this value shall be zero. Note that multiple parti… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8 | NodehrFSTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1 | NodehrFSEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.1 | Scalarhrfsindex | read-only | mandatory | A unique value for each file system local to this host. The value for each file system must remain constant at least from one re-initialization of the agent to… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.2 | Scalarhrfsmountpoint | read-only | mandatory | The path name of the root of this file system. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additional info… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.3 | Scalarhrfsremotemountpoint | read-only | mandatory | A description of the name and/or address of the server that this file system is mounted from. This may also include parameters such as the mount point on the r… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.4 | Scalarhrfstype | read-only | mandatory | The value of this object identifies the type of this file system. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more detai… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.5 | Scalarhrfsaccess | read-write | mandatory | An indication if this file system is logically configured by the operating system to be readable and writable or only readable. This does not represent any loc… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.6 | Scalarhrfsbootable | read-only | mandatory | A flag indicating whether this file system is bootable. Refer to RFC 1514, Host Resources MIB, http://ds.internic.net/rfc/rfc1514.txt, for more details. Additi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.7 | Scalarhrfsstorageindex | read-only | mandatory | The index of the hrStorageEntry that represents information about this file system. If there is no such information available, then this value shall be zero. T… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.8 | Scalarhrfslastfullbackupdate | read-only | mandatory | The last date at which this complete file system was copied to another storage device for backup. This information is useful for ensuring that backups are bein… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.8.1.9 | Scalarhrfslastpartialbackupdate | read-only | mandatory | The last date at which a portion of this file system was copied to another storage device for backup. This information is useful for ensuring that backups are … |