LaserJet5Si-Mopier-MIB
707 objects
No module-level DESCRIPTION found.
Imported Objects
| SNMPv2-SMI | enterprises |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.11 | Nodehp | |||
| 1.3.6.1.4.1.11.2 | Nodenm | |||
| 1.3.6.1.4.1.11.2.3 | Nodehpsystem | |||
| 1.3.6.1.4.1.11.2.3.9 | Nodenet-peripheral | |||
| 1.3.6.1.4.1.11.2.3.9.4 | Nodenetdm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2 | Nodedm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1 | Nodedevice | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1 | Nodesystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1 | Nodesettings-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.1 | Scalarenergy-star | read-write | optional | Returns or changes the Energy Star sleep value. If the value is greater than zero, then the device will go into energy saving sleep mode after the print engine… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2 | Scalarsleep-mode | read-write | optional | Returns eTrue if the device is in energy saving sleep mode, otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes the device to wake up, if it is in sl… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2 | Nodestatus-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.5 | Scalaron-off-line | read-write | optional | To bring the PDL processing sub-system on or off line. If the device is a printer, then the printer does not process print job data when the printer is off lin… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6 | Scalarcontinue | write-only | optional | A device can support a class of errors called continuable errors. When a continuable error is encountered, the device requires a continue event to occur before… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7 | Scalarauto-continue | read-write | optional | Indicates if the device will automatically continue after encountering a continuable error. If AUTO- CONTINUE is set to eOn, the device will automatically gene… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.35 | Scalarjob-input-auto-continue-timeout | read-write | optional | The number of seconds the device waits after a job related continuable error occurs before automatically continuing. An example job related continuable error i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.36 | Scalarjob-input-auto-continue-mode | read-write | optional | Returns or sets the device behavior when the desired media is not currently available. cCancelJob - The device cancels the job. The device POS should explain w… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37 | Nodebackground-message | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1 | Nodebackground-message1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1 | Scalarbackground-status-msg-line1-part1 | read-write | optional | The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2 | Nodebackground-message2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2.1 | Scalarbackground-status-msg-line2-part1 | read-write | optional | The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.38 | Scalarerror-log-clear | write-only | optional | Setting this object clears all the entries in the error log sub-tree. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.40 | Scalarjob-output-auto-continue-timeout | read-write | optional | Returns or sets the time that the printer will wait after an output bin becomes full and the printer is trying to deliver a sheet of media to that output bin. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3 | Nodeid | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.1 | Scalarmodel-number | read-only | optional | Identifies the device model number as listed in the HP corporate price list (e.g. C2121A for DeskJet 500C). The string is as specific as possible. Products sho… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.2 | Scalarmodel-name | read-only | optional | Identifies the device model name (e.g. ''DeskJet 1200C''). The string is as specific as possible. Capitalization and spacing should match family naming convent… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.3 | Scalarserial-number | read-only | optional | Identifies the serial number for the device. If the SERIAL-NUMBER object is set by the user, then setting the object does not need to be protected. If the SERI… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.10 | Scalardevice-name | read-write | optional | User defined device name. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.11 | Scalardevice-location | read-write | optional | User defined device location. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as muc… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12 | Scalarasset-number | read-write | optional | User defined asset number. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much a… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4 | Nodeinterface | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1 | Nodesimm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1 | Nodesimm1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.4 | Scalarsimm1-type | read-only | optional | Returns an indication of the type of option installed in SIMM slot 1. eEmpty means the device did not detect any option installed in the interface slot. eUnkno… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.5 | Scalarsimm1-capacity | read-only | optional | Returns an indication of the capacity of the SIMM installed in SIMM slot 1. The capacity is dependent on the type of option, as indicated by the SIMM1-TYPE obj… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2 | Nodesimm2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.4 | Scalarsimm2-type | read-only | optional | Returns an indication of the type of option installed in SIMM slot 2. See SIMM1-TYPE for a description. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.5 | Scalarsimm2-capacity | read-only | optional | Returns an indication of the capacity of the SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a description. Additional information: Returns an indication… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3 | Nodesimm3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.4 | Scalarsimm3-type | read-only | optional | Returns an indication of the type of option installed in SIMM slot 3. See SIMM1-TYPE for a description. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.5 | Scalarsimm3-capacity | read-only | optional | Returns an indication of the capacity of the SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a description. Additional information: Returns an indication… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4 | Nodesimm4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.4 | Scalarsimm4-type | read-only | optional | Returns an indication of the type of option installed in SIMM slot 4. See SIMM1-TYPE for a description. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.5 | Scalarsimm4-capacity | read-only | optional | Returns an indication of the capacity of the SIMM installed in SIMM slot 4. See SIMM1-CAPACITY for a description. Additional information: Returns an indication… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3 | Nodemio | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1 | Nodemio1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.3 | Scalarmio1-manufacturing-info | read-only | optional | Returns information describing the manufacture of the I/O card installed in MIO interface 1. May include serial number and firmware revision. Additional inform… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.4 | Scalarmio1-type | read-only | optional | Returns an indication of the type of option installed in MIO interface 1. See SIMM1-TYPE for an explanation of the enumerations. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2 | Nodemio2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.3 | Scalarmio2-manufacturing-info | read-only | optional | Returns information describing the manufacture of the I/O card installed in MIO interface 2. May include serial number and firmware revision. Additional inform… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.4 | Scalarmio2-type | read-only | optional | Returns an indication of the type of option installed in MIO interface 2. See SIMM1-TYPE for an explanation of the enumerations. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5 | Nodephd | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1 | Nodephd1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.1 | Scalarphd1-model | read-only | optional | Returns product information identifying the PHD device. Example: XXXX |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.2 | Scalarphd1-manufacturing-info | read-only | optional | Returns information describing the manufacture of this particular PHD. May include serial number and firmware revision. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.3 | Scalarphd1-type | read-only | optional | Returns an indication of the type of option installed in this particular SIMM interface See SIMM1-TYPE for an explanation of the enumerations. Additional infor… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.1.4 | Scalarphd1-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2 | Nodephd2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.1 | Scalarphd2-model | read-only | optional | Returns product information identifying PHD device 2. Example: XXXX |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.2 | Scalarphd2-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 2. May include serial number and firmware revision. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.3 | Scalarphd2-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 2. See SIMM1-TYPE for an explanation of the enumerations. Additional information: Extern… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.2.4 | Scalarphd2-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3 | Nodephd3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.1 | Scalarphd3-model | read-only | optional | Returns product information identifying PHD device 3. Additional information: The value returned by Tlatoani depends on the current mode of the device. The pos… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.2 | Scalarphd3-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 3. May include serial number and firmware revision. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.3 | Scalarphd3-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 3. See SIMM1-TYPE for an explanation of the enumerations. Additional information: Extern… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.3.4 | Scalarphd3-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4 | Nodephd4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.1 | Scalarphd4-model | read-only | optional | Returns product information identifying PHD device 4. Additional information: Returns product information identifying the PHD4 device. Example: OUTBIN STAPLER … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.2 | Scalarphd4-manufacturing-info | read-only | optional | Returns information describing the manufacture of PHD 4. May include serial number and firmware revision. Additional information: Returns information describin… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.3 | Scalarphd4-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 4. See SIMM1-TYPE for an explanation of the enumerations. Additional information: The en… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.4.4 | Scalarphd4-capacity | read-only | optional | Returns an indication of the capacity of the installed option. See SIMM1-CAPACITY for an explanation of the meaning of the value of this object. Additional inf… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.5 | Nodephd5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.5.3 | Scalarphd5-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 5. See SIMM1-TYPE for an explanation of the enumerations. Additional information: Extern… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.6 | Nodephd6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5.6.3 | Scalarphd6-type | read-only | optional | Returns an indication of the type of option installed in PHD interface 6. See SIMM1-TYPE for an explanation of the enumerations. Additional information: Extern… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5 | Nodetest | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5.1 | Scalarself-test | read-write | optional | Writing this object allows a device self test to be started. Reading this object provides an indication what self-test is currently executing, if any. Actual s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.5.2 | Scalarprint-internal-page | read-write | optional | Writing this object to a value other than eNotPrintingAnInternalPage causes the device to attempt to print an internally generated page. Reading this object pr… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6 | Nodejob | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1 | Nodesettings-job | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.2 | Scalarcancel-job | write-only | optional | Cancels the print job whose ID matches the value written to the CANCEL-JOB object. The host first learns the job ID using the CURRENT-JOB-PARSING-ID command. I… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.3 | Scalarjob-info-change-id | read-only | optional | Returns the current value of an object in the job-info sub-tree whose value has changed. Define the object identifier for the object whose value has changed as… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2 | Nodeactive-print-jobs | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2.1 | Nodejob-being-parsed | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.2.1.1 | Scalarcurrent-job-parsing-id | read-only | optional | Contains the printer assigned job identification for the job currently being processed by the processing PDL sub- system. The job ID is a monotonically increas… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5 | Nodejob-info | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.1 | Scalarjob-info-name1 | read-only | optional | Contains the first part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: The job name is the s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.2 | Scalarjob-info-name2 | read-only | optional | Contains the second part of this print job's name. The last OID field for this dynamic object contains the job ID. Additional information: See JOB-INFO-NAME1. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.10 | Scalarjob-info-stage | read-only | optional | Indicates what printer sub-systems are currently processing this print job. The last OID field for this dynamic object contains the job ID. cSourceSubsystem - … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.11 | Scalarjob-info-io-source | read-only | optional | Indicates which I/O source, the print job was received over. The value maps to port numbering scheme supported in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.12 | Scalarjob-info-pages-processed | read-only | optional | Indicates the number of pages processed by the processing subsystem. If neither the cSourceSubsystem or the cProcessingSubsystem items are in the associated JO… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.13 | Scalarjob-info-pages-printed | read-only | optional | Indicates the number of pages printed by the destination subsystem. If non of the cSourceSubsystem, cProcessingSubsystem or cDestinationSubsystem items are in … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.14 | Scalarjob-info-size | read-only | optional | Indicates the number of bytes of data processed by the processing subsystem. If neither of the cSourceSubsystem or cProcessingSubsystem items are in the associ… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.15 | Scalarjob-info-state | read-only | optional | Indicates the state of the job. The last OID field for this dynamic object contains the job ID. eAborted - the print job was aborted. eWaitingForResources - th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.19 | Scalarjob-info-outcome | read-only | optional | Indicates if any warning or error conditions were encountered while processing the assoicated job. The last OID field for this dynamic object contains the job … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.20 | Scalarjob-info-outbins-used | read-only | optional | Indicates which output bins this job has delivered printed pages to. The last OID field for this dynamic object contains the job ID. Additional information: Th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.22 | Scalarjob-info-physical-outbins-used | read-only | optional | |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23 | Nodejob-info-attribute | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.1 | Scalarjob-info-attr-1 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. Attribute objects are saved sequentially, starting with 1, after the start of a job. If mor… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.2 | Scalarjob-info-attr-2 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.3 | Scalarjob-info-attr-3 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.4 | Scalarjob-info-attr-4 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.5 | Scalarjob-info-attr-5 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.6 | Scalarjob-info-attr-6 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.7 | Scalarjob-info-attr-7 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.8 | Scalarjob-info-attr-8 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.9 | Scalarjob-info-attr-9 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.10 | Scalarjob-info-attr-10 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.11 | Scalarjob-info-attr-11 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.12 | Scalarjob-info-attr-12 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.13 | Scalarjob-info-attr-13 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.14 | Scalarjob-info-attr-14 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.15 | Scalarjob-info-attr-15 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.16 | Scalarjob-info-attr-16 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.17 | Scalarjob-info-attr-17 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.18 | Scalarjob-info-attr-18 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.19 | Scalarjob-info-attr-19 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.20 | Scalarjob-info-attr-20 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.21 | Scalarjob-info-attr-21 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.22 | Scalarjob-info-attr-22 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.23 | Scalarjob-info-attr-23 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.24 | Scalarjob-info-attr-24 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.25 | Scalarjob-info-attr-25 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.26 | Scalarjob-info-attr-26 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.27 | Scalarjob-info-attr-27 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.28 | Scalarjob-info-attr-28 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.29 | Scalarjob-info-attr-29 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.30 | Scalarjob-info-attr-30 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.31 | Scalarjob-info-attr-31 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.5.23.32 | Scalarjob-info-attr-32 | read-only | optional | Returns the value that was set in PJL via the SET JOBATTR= command. See JOB-INFO-ATTR-1 for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10 | Nodefile-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.1 | Nodesettings-file-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.1.1 | Scalarfile-system-memory | read-only | optional | The amount of memory, in bytes, used by the file system to buffer file data. Additional information: Reports the amount of memory, in bytes, reserved for use b… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.1.2 | Scalarfile-system-max-open-files | read-write | optional | The number of open files allowed at one time. Opening a file when the maximum number of files are currently open will fail. Additional information: Indicates t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2 | Nodestatus-file-system | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.1 | Scalarfile-system-statistic-read-open | read-only | optional | The number of times the file system has received requests to open a file for reading. Opening a file for both reading and writing will cause this value to chan… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.2 | Scalarfile-system-statistic-write-open | read-only | optional | The number of times the file system has received requests to open a file for writing. Opening a file for both reading and writing will cause this value to chan… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.3 | Scalarfile-system-statistic-successful | read-only | optional | A counter indicating the number of file system requests that completed successfully. The POS should state if a power cycle causes the counter is be reset to ze… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.4 | Scalarfile-system-statistic-unsuccessful | read-only | optional | A counter indicating the number of file system requests that completed unsuccessfully. The POS should state if a power cycle causes the counter is be reset to … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.5 | Scalarfile-system-statistic-current-memory-usage | read-only | optional | A value indicating the number of bytes of RAM currently used by the file system firmware. Additional information: Reset to the factory default value after a po… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.2.6 | Scalarfile-system-statistic-max-memory-usage | read-only | optional | A value indicating the maximum number of bytes of RAM used by the file system firmware. The POS should state if the value is reset to zero after a power cycle.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3 | Nodefile-systems | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.2 | Nodefile-system2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.10.3.2.6 | Scalarfile-system2-initialize-volume | write-only | optional | Setting this object to eInitializing causes file system 2 to be initialized. Reading this object indicates if the file system is currently being initialized. A… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11 | Nodeerrorlog | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.1 | Nodeerror1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.1.1 | Scalarerror1-time-stamp | read-only | optional | Contains a time stamp indicating when error 1 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.1.2 | Scalarerror1-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.2 | Nodeerror2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.2.1 | Scalarerror2-time-stamp | read-only | optional | Contains a time stamp indicating when error 2 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.2.2 | Scalarerror2-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.3 | Nodeerror3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.3.1 | Scalarerror3-time-stamp | read-only | optional | Contains a time stamp indicating when error 3 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.3.2 | Scalarerror3-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.4 | Nodeerror4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.4.1 | Scalarerror4-time-stamp | read-only | optional | Contains a time stamp indicating when error 4 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.4.2 | Scalarerror4-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.5 | Nodeerror5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.5.1 | Scalarerror5-time-stamp | read-only | optional | Contains a time stamp indicating when error 5 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.5.2 | Scalarerror5-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.6 | Nodeerror6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.6.1 | Scalarerror6-time-stamp | read-only | optional | Contains a time stamp indicating when error 6 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.6.2 | Scalarerror6-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.7 | Nodeerror7 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.7.1 | Scalarerror7-time-stamp | read-only | optional | Contains a time stamp indicating when error 7 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.7.2 | Scalarerror7-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.8 | Nodeerror8 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.8.1 | Scalarerror8-time-stamp | read-only | optional | Contains a time stamp indicating when error 8 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.8.2 | Scalarerror8-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.9 | Nodeerror9 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.9.1 | Scalarerror9-time-stamp | read-only | optional | Contains a time stamp indicating when error 9 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.9.2 | Scalarerror9-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.10 | Nodeerror10 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.10.1 | Scalarerror10-time-stamp | read-only | optional | Contains a time stamp indicating when error 10 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.10.2 | Scalarerror10-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.11 | Nodeerror11 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.11.1 | Scalarerror11-time-stamp | read-only | optional | Contains a time stamp indicating when error 11 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.11.2 | Scalarerror11-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.12 | Nodeerror12 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.12.1 | Scalarerror12-time-stamp | read-only | optional | Contains a time stamp indicating when error 12 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.12.2 | Scalarerror12-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.13 | Nodeerror13 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.13.1 | Scalarerror13-time-stamp | read-only | optional | Contains a time stamp indicating when error 13 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.13.2 | Scalarerror13-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.14 | Nodeerror14 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.14.1 | Scalarerror14-time-stamp | read-only | optional | Contains a time stamp indicating when error 14 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.14.2 | Scalarerror14-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.15 | Nodeerror15 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.15.1 | Scalarerror15-time-stamp | read-only | optional | Contains a time stamp indicating when error 15 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.15.2 | Scalarerror15-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.16 | Nodeerror16 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.16.1 | Scalarerror16-time-stamp | read-only | optional | Contains a time stamp indicating when error 16 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.16.2 | Scalarerror16-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.17 | Nodeerror17 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.17.1 | Scalarerror17-time-stamp | read-only | optional | Contains a time stamp indicating when error 17 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.17.2 | Scalarerror17-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.18 | Nodeerror18 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.18.1 | Scalarerror18-time-stamp | read-only | optional | Contains a time stamp indicating when error 18 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.18.2 | Scalarerror18-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.19 | Nodeerror19 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.19.1 | Scalarerror19-time-stamp | read-only | optional | Contains a time stamp indicating when error 19 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.19.2 | Scalarerror19-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.20 | Nodeerror20 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.20.1 | Scalarerror20-time-stamp | read-only | optional | Contains a time stamp indicating when error 20 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.20.2 | Scalarerror20-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.21 | Nodeerror21 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.21.1 | Scalarerror21-time-stamp | read-only | optional | Contains a time stamp indicating when error 21 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.21.2 | Scalarerror21-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.22 | Nodeerror22 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.22.1 | Scalarerror22-time-stamp | read-only | optional | Contains a time stamp indicating when error 22 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.22.2 | Scalarerror22-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.23 | Nodeerror23 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.23.1 | Scalarerror23-time-stamp | read-only | optional | Contains a time stamp indicating when error 23 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.23.2 | Scalarerror23-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.24 | Nodeerror24 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.24.1 | Scalarerror24-time-stamp | read-only | optional | Contains a time stamp indicating when error 24 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.24.2 | Scalarerror24-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.25 | Nodeerror25 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.25.1 | Scalarerror25-time-stamp | read-only | optional | Contains a time stamp indicating when error 25 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.25.2 | Scalarerror25-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.26 | Nodeerror26 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.26.1 | Scalarerror26-time-stamp | read-only | optional | Contains a time stamp indicating when error 26 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.26.2 | Scalarerror26-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.27 | Nodeerror27 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.27.1 | Scalarerror27-time-stamp | read-only | optional | Contains a time stamp indicating when error 27 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.27.2 | Scalarerror27-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.28 | Nodeerror28 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.28.1 | Scalarerror28-time-stamp | read-only | optional | Contains a time stamp indicating when error 28 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.28.2 | Scalarerror28-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.29 | Nodeerror29 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.29.1 | Scalarerror29-time-stamp | read-only | optional | Contains a time stamp indicating when error 29 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.29.2 | Scalarerror29-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.30 | Nodeerror30 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.30.1 | Scalarerror30-time-stamp | read-only | optional | Contains a time stamp indicating when error 30 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.30.2 | Scalarerror30-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.31 | Nodeerror31 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.31.1 | Scalarerror31-time-stamp | read-only | optional | Contains a time stamp indicating when error 31 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.31.2 | Scalarerror31-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.32 | Nodeerror32 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.32.1 | Scalarerror32-time-stamp | read-only | optional | Contains a time stamp indicating when error 32 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.32.2 | Scalarerror32-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.33 | Nodeerror33 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.33.1 | Scalarerror33-time-stamp | read-only | optional | Contains a time stamp indicating when error 33 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.33.2 | Scalarerror33-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.34 | Nodeerror34 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.34.1 | Scalarerror34-time-stamp | read-only | optional | Contains a time stamp indicating when error 34 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.34.2 | Scalarerror34-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.35 | Nodeerror35 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.35.1 | Scalarerror35-time-stamp | read-only | optional | Contains a time stamp indicating when error 35 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.35.2 | Scalarerror35-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.36 | Nodeerror36 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.36.1 | Scalarerror36-time-stamp | read-only | optional | Contains a time stamp indicating when error 36 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.36.2 | Scalarerror36-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.37 | Nodeerror37 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.37.1 | Scalarerror37-time-stamp | read-only | optional | Contains a time stamp indicating when error 37 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.37.2 | Scalarerror37-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.38 | Nodeerror38 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.38.1 | Scalarerror38-time-stamp | read-only | optional | Contains a time stamp indicating when error 38 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.38.2 | Scalarerror38-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.39 | Nodeerror39 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.39.1 | Scalarerror39-time-stamp | read-only | optional | Contains a time stamp indicating when error 39 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.39.2 | Scalarerror39-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.40 | Nodeerror40 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.40.1 | Scalarerror40-time-stamp | read-only | optional | Contains a time stamp indicating when error 40 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.40.2 | Scalarerror40-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.41 | Nodeerror41 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.41.1 | Scalarerror41-time-stamp | read-only | optional | Contains a time stamp indicating when error 41 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.41.2 | Scalarerror41-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.42 | Nodeerror42 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.42.1 | Scalarerror42-time-stamp | read-only | optional | Contains a time stamp indicating when error 42 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.42.2 | Scalarerror42-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.43 | Nodeerror43 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.43.1 | Scalarerror43-time-stamp | read-only | optional | Contains a time stamp indicating when error 43 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.43.2 | Scalarerror43-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.44 | Nodeerror44 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.44.1 | Scalarerror44-time-stamp | read-only | optional | Contains a time stamp indicating when error 44 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.44.2 | Scalarerror44-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.45 | Nodeerror45 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.45.1 | Scalarerror45-time-stamp | read-only | optional | Contains a time stamp indicating when error 45 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.45.2 | Scalarerror45-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.46 | Nodeerror46 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.46.1 | Scalarerror46-time-stamp | read-only | optional | Contains a time stamp indicating when error 46 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.46.2 | Scalarerror46-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.47 | Nodeerror47 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.47.1 | Scalarerror47-time-stamp | read-only | optional | Contains a time stamp indicating when error 47 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.47.2 | Scalarerror47-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.48 | Nodeerror48 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.48.1 | Scalarerror48-time-stamp | read-only | optional | Contains a time stamp indicating when error 48 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.48.2 | Scalarerror48-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.49 | Nodeerror49 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.49.1 | Scalarerror49-time-stamp | read-only | optional | Contains a time stamp indicating when error 49 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.49.2 | Scalarerror49-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.50 | Nodeerror50 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.50.1 | Scalarerror50-time-stamp | read-only | optional | Contains a time stamp indicating when error 50 occurred. Example time stamps include the actual time the error occurred (in seconds since Jan. 1, 1970), and th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.11.50.2 | Scalarerror50-code | read-only | optional | Contains a device specific error code. Each device POS should list what errors are logged to the error log and the meaning of each supported error code value. … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12 | Noderesource-manager | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12.3 | Nodemass-storage-resources | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12.3.1 | Scalarmass-storage-resource-change-counter | read-only | optional | A counter which changes when a mass storage based resource has been added or deleted. Additional information: The value of this counter changes each time the M… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.12.3.2 | Scalarmass-storage-resource-changed | write-only | optional | Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE- COUNTER to be incremented. Additional information: Returns <noSuchName> status if attempting to access th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13 | Noderemote-procedure-call | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.1 | Nodesettings-rpc | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.1.1 | Scalarrpc-test-return-code | write-only | optional | This test object that will not be supported in any released product. Setting this object allows the next RPC call return code to be specified. The POS will spe… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.1.2 | Scalarrpc-bind-protocol-address | read-write | optional | Array of Berkeley sockets style protocol addresses used to bind RPC to a communications protocol family. Setting an instance of this array object to a zero len… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2 | Nodestatus-rpc | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2.1 | Scalarrpc-statistic-successful | read-only | optional | A counter indicating the number of RPC requests that completed successfully (reply_data stat is SUCCESS). The POS should state if a power cycle causes the coun… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2.2 | Scalarrpc-statistic-unsuccessful | read-only | optional | A counter indicating the number of RPC requests that completed unsuccessfully. The POS should state if a power cycle causes the counter is be reset to zero. Ad… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.2.3 | Scalarrpc-bound-protocol-address | read-only | optional | An array of Berkeley sockets style protocol addresses that the NFS service has been bound to successful. The format is that same as the array of RPC-BIND-PROTO… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3 | Noderpc-services | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.1 | Nodemount | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.1.1 | Nodesettings-mount | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.1.1.1 | Scalarmount-test-return-code | write-only | optional | This test object that will not be supported in any released product. Setting this object allows the next mount call return code to be specified. The POS will s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2 | Nodenfs-server | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1 | Nodesettings-nfs-server | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1.1 | Scalarnfs-server-memory | read-only | optional | The amount of memory, in bytes, used by the Network File System server to buffer file data. Additional information: Reports the amount of memory, in bytes, res… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1.2 | Scalarnfs-server-read-size | read-write | optional | The maximum amount of data transferred in one NFS server read data call. Additional information: A side effect of the implementation is initializing the mass s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.1.3 | Scalarnfs-server-write-size | read-write | optional | The maximum amount of data transferred in one NFS server write data call. Additional information: A side effect of the implementation is initializing the mass … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2 | Nodestatus-nfs-server | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.1 | Scalarnfs-server-statistic-successful | read-only | optional | A counter indicating the number of NFS requests that completed without error. The POS should state if a power cycle causes the counter is be reset to zero. Add… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.2 | Scalarnfs-server-statistic-unsuccessful | read-only | optional | A counter indicating the number of NFS requests that completed with an NFS status other than NFS_OK (0). The POS should state if a power cycle causes the count… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.4 | Scalarnfs-server-statistic-current-memory-usage | read-only | optional | A value indicating the number of bytes of RAM currently used by the NFS firmware. Additional information: Reset to the factory default value after a power cycl… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.2.2.5 | Scalarnfs-server-statistic-max-memory-usage | read-only | optional | A value indicating the maximum number of bytes of RAM used by the NFS firmware. The POS should state if the value is reset to zero after a power cycle. Additio… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3 | Noderpc-bind | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.1 | Nodesettings-rpc-bind | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.1.1 | Scalarrpc-bind-test-return-code | write-only | optional | This test object that will not be supported in any released product. Setting this object allows the next RPC bind call return code to be specified. The POS wil… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.2 | Nodestatus-rpc-bind | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.2.1 | Scalarrpc-bind-statistic-successful | read-only | optional | A counter indicating the number of RPC bind (RPC program number 100000, version 2) requests that completed successfully. The POS should state if a power cycle … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.13.3.3.2.2 | Scalarrpc-bind-statistic-unsuccessful | read-only | optional | A counter indicating the number of RPC bind (RPC program number 100000, version 2) requests that completed unsuccessfully. The POS should state if a power cycl… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14 | Nodexport-interface | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14.2 | Nodestatus-xip | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14.2.1 | Scalarxip-statistic-processed | read-only | optional | A counter indicating the number of XIP requests that were processed. The POS should state if a power cycle causes the counter is be reset to zero. Additional i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.14.2.2 | Scalarxip-statistic-data-in-dropped | read-only | optional | A counter indicating the number of XIP data in datagrams that were dropped (typically due to the printer being flooded with XIP requests ). The POS should stat… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15 | Nodemass-storage-block-driver | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.3 | Nodemass-storage-block-drivers | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.3.2 | Nodemass-storage-bd2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.3.2.1 | Nodesettings-msbd2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.1.15.3.2.1.1 | Scalardisk-storage-block-driver2-test-return-code | write-only | optional | This test object will not be supported in any released product. Setting this object allows the next call to the mass storage block driver 2 to return the speci… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2 | Nodesource-subsystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1 | Nodeio | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1 | Nodesettings-io | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.1 | Scalario-timeout | read-write | optional | The amount of time, in seconds, to wait for more print job data to be received before an I/O timeout occurs. The I/O channel being timed is the I/O channel tha… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.2 | Scalario-switch | read-only | optional | Indicates if the device will switch between I/O channels when a job boundary is encountered and print job data is available on another I/O channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.5 | Scalario-buffering | read-write | optional | Returns or controls the manner in which the device performs I/O data buffering. I/O data buffering allows additional print job data to be buffered by the I/O s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.6 | Scalario-buffer-size | read-write | optional | Returns or configures the amount of memory, in bytes, dedicated to I/O print job data buffering. Attempting to set to an unsupported value causes the device to… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.1.7 | Scalarmaximum-io-buffering-memory | read-only | optional | Returns the maximum amount of additional memory, in bytes, that can be dedicated to buffering print job data. Additional information: Memory for I/O Buffering … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3 | Nodeports | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3.1 | Nodeport1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3.1.4 | Scalarport1-parallel-speed | read-write | optional | Returns or changes the maximum parallel I/O port speed, for port 1. This object is only supported if this port is a parallel port. An eSlow setting causes a 10… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.2.1.3.1.5 | Scalarport1-parallel-bidirectionality | read-write | optional | Returns or changes whether the parallel I/O port supports bidirectional communication for port 1. This object is only supported if this port is a parallel port… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3 | Nodeprocessing-subsystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3 | Nodepdl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1 | Nodesettings-pdl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.4 | Scalardefault-copies | read-write | optional | Returns or changes default copies. Default copies is the default values used by the PDL to control the number of copies of each page in the print job that are … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.5 | Scalarform-feed | write-only | optional | Instructs the PDL processing sub-system to finishing processing the current page of the current job. Form feed is also known as close page or eject page. If th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.6 | Scalarresource-saving | read-write | optional | Returns or changes PDL resource saving. Resource saving stores a PDL's permanent soft resources, like fonts, even when another PDL is active. Resource saving i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.7 | Scalarmaximum-resource-saving-memory | read-only | optional | Returns the maximum amount of additional memory, in bytes, that can be dedicated to holding PDL permanent soft resources. Additional information: The following… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.8 | Scalardefault-vertical-black-resolution | read-write | optional | Returns or changes the value of the default vertical black resolution. The units are dots per inch. Additional information: In LaserJet 5Si changing this OID a… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.9 | Scalardefault-horizontal-black-resolution | read-write | optional | Returns or changes the value of the default horizontal black resolution. The units are dots per inch. Additional information: In LaserJet 5Si changing this OID… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.10 | Scalardefault-page-protect | read-write | optional | Returns or changes the default page protection behavior. If eOff, the device does not reserve memory for holding the entire raster form of a processed page. If… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.11 | Scalardefault-lines-per-page | read-write | optional | Returns or changes the default number of lines per page. The POS indicates the supported values. An unsupported value causes the printer to use the closest sup… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.12 | Scalardefault-vmi | read-write | optional | Returns or changes the default vertical motion index. The unit of measure for VMI is centipoints per line. The POS indicates the supported values. An unsupport… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.13 | Scalardefault-media-size | read-write | optional | This indicates the default media size. A write of an unsupported value cases an <badValue>. Complete list of supported media sizes along with their dimensions … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.19 | Scalarcold-reset-media-size | read-write | optional | Returns or sets the media size that is used as the DEFAULT-MEDIA-SIZE when a cold reset occurs. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.22 | Scalardefault-media-name | read-write | optional | Returns or sets the media name that is used until the media name is changed by a print job command. Additional information: This string must be one of the MEDI… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.2 | Nodestatus-pdl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.2.2 | Scalarform-feed-needed | read-only | optional | Indicates if the PDL processing sub-system has made marks on the current page and the source subsystem has been idle for a device specific amount of time. Addi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3 | Nodepdl-pcl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.2 | Scalarpcl-resource-saving-memory-size | read-write | optional | Returns or changes the amount of resource saving memory set aside to hold permanent soft PCL resources. Additional information: The value returned by this obje… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.5 | Scalarpcl-total-page-count | read-only | optional | Total number of PCL pages printed by the device. Additional information: In LaserJet 5Si the PCL page count is kept in NVRAM however the NVRAM value is only up… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.13 | Scalarpcl-default-font-height | read-write | optional | Returns or changes the default PCL height. Height is an approximate measure of the body of the type in centipoints. A centipoint is 1/7200 inch. Height applies… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.14 | Scalarpcl-default-font-source | read-write | optional | Returns or changes the value of the default font source variable in NVRAM. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.15 | Scalarpcl-default-font-number | read-write | optional | Returns or changes the value of the default font number variable in NVRAM. Writing an unsupported value causes the printer to generate an <badValue>. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.3.16 | Scalarpcl-default-font-width | read-write | optional | Returns or changes the default PCL font width. Width is expressed as the width of a character in centipoints. A centipoint is 1/7200 inch. Width applies only t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4 | Nodepdl-postscript | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.2 | Scalarpostscript-resource-saving-memory-size | read-write | optional | Returns or changes the amount of resource saving memory set aside to hold permanent soft PostScript resources. Additional information: The value returned by th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.5 | Scalarpostscript-total-page-count | read-only | optional | Total number of PostScript pages printed by the device. Additional information: This object is only supported if PostScript option is installed. In LaserJet 5S… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.11 | Scalarpostscript-print-errors | read-write | optional | Returns or changes the value of the print PostScript errors setting. If eOn, PostScript prints an error page showing the error encountered and the stack at the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.12 | Scalarpostscript-jam-recovery | read-write | optional | Returns or changes the PostScript jam recovery setting. If eOn, then the device will reprint PostScript pages, if those pages jam. Additional information: This… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.5 | Nodepjl | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.3.5.1 | Scalarpjl-password | read-only | optional | Returns PJL password, if the password is not set (zero). If the password is set, then attempting to retrieve the password causes an <genErr> to occur and will … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4 | Nodedestination-subsystem | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1 | Nodeprint-engine | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1 | Nodesettings-prt-eng | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.2 | Scalaroverride-media-name | read-write | optional | Sets a string identifying the media name that is to be used in place of the currently requested media. The substitution will continue until another media is se… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.3 | Scalaroverride-media-size | read-write | optional | Sets the media size that is to be used in place of the currently requested media size. Additional information: When a request is received to print on a size an… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.5 | Scalarprint-density | read-write | optional | Returns or sets the print density setting. Print density is the instantaneous amount of marking agent applied to the paper while printing. A value of zero has … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.2 | Nodestatus-prt-eng | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.2.22 | Scalarduplex-page-count | read-only | optional | Total number of sheets of media that have been duplex printed. A sheet is counted if it travels through the duplex page path, regardless of whether or not mark… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3 | Nodeintray | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1 | Nodesettings-intray | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.1.5 | Scalarmp-tray | read-only | optional | Returns or changes the value of the multi-purpose (MP) tray configuration variable. The MP tray can be configured to operate as an additional input tray (eCass… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3 | Nodeintrays | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.4 | Nodeintray4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.4.12 | Scalartray4-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this input tray. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.5 | Nodeintray5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.3.3.5.12 | Scalartray5-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this input tray. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4 | Nodeoutbin | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.1 | Nodesettings-outbin | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.1.4 | Scalaroverflow-bin | read-write | optional | Returns or sets the bin that will be used for additional sheets of media when the current bin is full and printing is allowed to continue. Additional informati… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3 | Nodeoutbins | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.1 | Nodeoutbin1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.1.9 | Scalaroutbin1-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.3 | Nodeoutbin3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.3.9 | Scalaroutbin3-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.3.11 | Scalaroutbin3-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.4 | Nodeoutbin4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.4.9 | Scalaroutbin4-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.4.11 | Scalaroutbin4-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.5 | Nodeoutbin5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.5.9 | Scalaroutbin5-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.5.11 | Scalaroutbin5-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.6 | Nodeoutbin6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.6.9 | Scalaroutbin6-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.6.11 | Scalaroutbin6-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.7 | Nodeoutbin7 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.7.9 | Scalaroutbin7-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.7.11 | Scalaroutbin7-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.8 | Nodeoutbin8 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.8.9 | Scalaroutbin8-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.8.11 | Scalaroutbin8-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.9 | Nodeoutbin9 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.9.9 | Scalaroutbin9-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.9.10 | Scalaroutbin9-maximum-binding | read-only | optional | The maximum number of sheets of 20 pound paper that can be bound by the binding device that serves this output bin. If a job exceeds this number and the job ha… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.9.11 | Scalaroutbin9-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.10 | Nodeoutbin10 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.10.9 | Scalaroutbin10-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.10.11 | Scalaroutbin10-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.11 | Nodeoutbin11 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.11.9 | Scalaroutbin11-override-mode | read-write | optional | Returns or sets the device behavior when this output bin condition causes printing to stop. cCancelJob - The device cancels the job. cOutbinFullOverride - The … |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.4.3.11.11 | Scalaroutbin11-phd | read-only | optional | Provides the number of the Paper Handling Device that contains this output bin. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.5 | Nodemarking-agent | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.5.1 | Nodesettings-marking-agent | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.5.1.3 | Scalarlow-marking-agent-processing | read-write | optional | Returns or changes how the device processes a low marking agent event. If eCont, then the device continues to print. If eStop, then the device stops until a co… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6 | Nodeimaging | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6.5 | Scalardefault-ret | read-write | optional | Returns or changes the Resolution Enhancement Technology setting. Devices that only support eOff and on should map all other values to on and always return the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.6.7 | Scalardefault-print-quality | read-write | optional | Returns or sets the default print quality. A value of zero has the lowest print quality. A value of 100 has the highest print quality. Each POS should document… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7 | Nodeph | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3 | Nodeph-devices | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.2 | Nodeph2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.2.2 | Scalarphd2-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.2.4 | Scalarphd2-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: This object returns th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.3 | Nodeph3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.3.2 | Scalarphd3-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.3.4 | Scalarphd3-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: This object returns th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.4 | Nodeph4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.4.2 | Scalarphd4-device-specific-command | write-only | optional | This object is used to send device-specific data to the paper handling device. The meaning of the device- specific command is dependent on the paper handling d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.7.3.4.4 | Scalarphd4-device-memory | read-only | optional | This object is used to read the current values stored in shared memory available from the paper handling device. Additional information: This object returns th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8 | Nodeprint-media | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.1 | Nodesettings-print-media | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.1.1 | Scalarmedia-names-available | read-write | optional | The value of this object controls which of the MEDIAx- NAME objects are supported. If a bit is set to zero, then attempting to get or set the corresponding MED… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3 | Nodemedia-info | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1 | Nodemedia1 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1.1 | Scalarmedia1-name | read-only | optional | Media 1 name. Additional information: The symbol set for this string is Roman-8. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1.2 | Scalarmedia1-short-name | read-only | optional | Length restricted version of the media name 1. The length restriction is required to allow the media name to be displayed on the device's control panel. The de… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.1.3 | Scalarmedia1-page-count | read-only | optional | Number of sheets of media 1 that have been printed. The device POS should state whether this value is lost across a power cycle or kept in NVRAM. Additional in… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2 | Nodemedia2 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2.1 | Scalarmedia2-name | read-only | optional | Media 2 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2.2 | Scalarmedia2-short-name | read-only | optional | Length restricted version of the media name 2. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.2.3 | Scalarmedia2-page-count | read-only | optional | Number of sheets of media 2 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3 | Nodemedia3 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3.1 | Scalarmedia3-name | read-only | optional | Media 3 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3.2 | Scalarmedia3-short-name | read-only | optional | Length restricted version of the media name 3. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.3.3 | Scalarmedia3-page-count | read-only | optional | Number of sheets of media 3 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4 | Nodemedia4 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4.1 | Scalarmedia4-name | read-only | optional | Media 4 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4.2 | Scalarmedia4-short-name | read-only | optional | Length restricted version of the media name 4. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.4.3 | Scalarmedia4-page-count | read-only | optional | Number of sheets of media 4 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5 | Nodemedia5 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5.1 | Scalarmedia5-name | read-only | optional | Media 5 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5.2 | Scalarmedia5-short-name | read-only | optional | Length restricted version of the media name 5. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.5.3 | Scalarmedia5-page-count | read-only | optional | Number of sheets of media 5 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6 | Nodemedia6 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6.1 | Scalarmedia6-name | read-only | optional | Media 6 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6.2 | Scalarmedia6-short-name | read-only | optional | Length restricted version of the media name 6. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.6.3 | Scalarmedia6-page-count | read-only | optional | Number of sheets of media 6 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7 | Nodemedia7 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7.1 | Scalarmedia7-name | read-only | optional | Media 7 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7.2 | Scalarmedia7-short-name | read-only | optional | Length restricted version of the media name 7. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.7.3 | Scalarmedia7-page-count | read-only | optional | Number of sheets of media 7 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8 | Nodemedia8 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8.1 | Scalarmedia8-name | read-only | optional | Media 8 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8.2 | Scalarmedia8-short-name | read-only | optional | Length restricted version of the media name 8. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.8.3 | Scalarmedia8-page-count | read-only | optional | Number of sheets of media 8 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9 | Nodemedia9 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9.1 | Scalarmedia9-name | read-only | optional | Media 9 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9.2 | Scalarmedia9-short-name | read-only | optional | Length restricted version of the media name 9. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.9.3 | Scalarmedia9-page-count | read-only | optional | Number of sheets of media 9 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10 | Nodemedia10 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10.1 | Scalarmedia10-name | read-only | optional | Media 10 name. Additional information: See MEDIA1-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10.2 | Scalarmedia10-short-name | read-only | optional | Length restricted version of the media name 10. See MEDIA1-SHORT-NAME for details. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.10.3 | Scalarmedia10-page-count | read-only | optional | Number of sheets of media 10 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11 | Nodemedia11 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11.1 | Scalarmedia11-name | read-write | optional | Media 11 name. Additional information: The maximum supported string length is 24 bytes. If the user entered string is too long, the device will store the first… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11.2 | Scalarmedia11-short-name | read-write | optional | Length restricted version of the media name 11. See MEDIA1-SHORT-NAME for details. Additional information: The maximum supported string length is 10 characters… |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.11.3 | Scalarmedia11-page-count | read-only | optional | Number of sheets of media 11 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA1-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.12 | Nodemedia12 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.12.1 | Scalarmedia12-name | read-write | optional | Media 12 name. Additional information: See MEDIA11-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.12.2 | Scalarmedia12-short-name | read-write | optional | Length restricted version of the media name 12. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA11-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.12.3 | Scalarmedia12-page-count | read-only | optional | Number of sheets of media 12 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA11-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13 | Nodemedia13 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13.1 | Scalarmedia13-name | read-write | optional | Media 13 name. Additional information: See MEDIA11-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13.2 | Scalarmedia13-short-name | read-write | optional | Length restricted version of the media name 13. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA11-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.13.3 | Scalarmedia13-page-count | read-only | optional | Number of sheets of media 13 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA11-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14 | Nodemedia14 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14.1 | Scalarmedia14-name | read-write | optional | Media 14 name. Additional information: See MEDIA11-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14.2 | Scalarmedia14-short-name | read-write | optional | Length restricted version of the media name 14. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA11-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.14.3 | Scalarmedia14-page-count | read-only | optional | Number of sheets of media 14 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA11-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15 | Nodemedia15 | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15.1 | Scalarmedia15-name | read-write | optional | Media 15 name. Additional information: See MEDIA11-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15.2 | Scalarmedia15-short-name | read-write | optional | Length restricted version of the media name 15. See MEDIA1-SHORT-NAME for details. Additional information: See MEDIA11-SHORT-NAME. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.3.15.3 | Scalarmedia15-page-count | read-only | optional | Number of sheets of media 15 that have been printed. See MEDIA1-PAGE-COUNT for details. Additional information: See MEDIA11-PAGE-COUNT. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7 | Nodetables | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2 | Nodechannel-table | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1 | Nodechannel-entry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.2 | Scalarchannel-bytes-sent | read-only | optional | The low order 31 bits of the number of bytes sent from the printer to the host on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.3 | Scalarchannel-bytes-received | read-only | optional | The low order 31 bits of the number of bytes received by the printer from the host on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.4 | Scalarchannel-io-errors | read-only | optional | The low order 31 bits of the number of I/O errors which have occured on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.5 | Scalarchannel-jobs-received | read-only | optional | The low order 31 bits of the number of print jobs which have been received on this logical channel. |
| 1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.6 | Scalarchannel-mio | read-only | optional | The number of the MIO card associated with this logical channel. If this logical channel is not associated with an MIO card a zero is returned. The value 1 is … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2 | Nodeprintmib | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5 | NodeprtGeneral | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1 | NodeprtGeneralTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1 | NodeprtGeneralEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.1 | Scalarprtgeneralconfigchanges | read-only | optional | Counts configuration changes that change the capabilities of a printer, such as the addition/deletion of input/output bins, the addition/deletion of interprete… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.2 | Scalarprtgeneralcurrentlocalization | read-write | optional | The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identif… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.3 | Scalarprtgeneralreset | read-write | optional | Setting this value to `powerCycleReset', `resetToNVRAM', or `resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will a… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.4 | Scalarprtgeneralcurrentoperator | read-write | optional | The name of the current human operator responsible for operating this printer. It is suggested that this string include information that would enable other hum… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.5 | Scalarprtgeneralserviceperson | read-write | optional | The name of the last human responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.6 | Scalarprtinputdefaultindex | read-only | optional | The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. Additional information:… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.7 | Scalarprtoutputdefaultindex | read-write | optional | The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.8 | Scalarprtmarkerdefaultindex | read-only | optional | The value of prtMarkerIndex corresponding to the default markersub-unit; that is, this object selects the default marker. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.9 | Scalarprtmediapathdefaultindex | read-write | optional | The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.10 | Scalarprtconsolelocalization | read-write | optional | The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to t… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.11 | Scalarprtconsolenumberofdisplaylines | read-only | optional | The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.12 | Scalarprtconsolenumberofdisplaychars | read-only | optional | The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical d… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.1.1.13 | Scalarprtconsoledisable | read-write | optional | This object enables or disables manual input from the operators console. Additional information: If the object prtConsoleDisable has value 'disabled' then manu… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2 | NodeprtStorageRefTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2.1 | NodeprtStorageRefEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.2.1.2 | Scalarprtstoragerefindex | read-only | optional | The value of the hrDeviceIndex of the printer device that this storageEntry is associated with. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3 | NodeprtDeviceRefTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3.1 | NodeprtDeviceRefEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.5.3.1.2 | Scalarprtdevicerefindex | read-only | optional | The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6 | NodeprtCover | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1 | NodeprtCoverTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1 | NodeprtCoverEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1.2 | Scalarprtcoverdescription | read-only | optional | The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.6.1.1.3 | Scalarprtcoverstatus | read-only | optional | The status of this cover sub-unit. Additional information: LaserJet 5Si detects a door open condition only when printing. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7 | NodeprtLocalization | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1 | NodeprtLocalizationTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1 | NodeprtLocalizationEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.2 | Scalarprtlocalizationlanguage | read-only | optional | A two character language code from ISO 639. Examples EN, GB, CA, FR, DE. Additional information: The languages supported by LaserJet 5Si are English, French, G… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.3 | Scalarprtlocalizationcountry | read-only | optional | A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ... Add… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.7.1.1.4 | Scalarprtlocalizationcharacterset | read-only | optional | The coded character set used for this localization. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8 | NodeprtInput | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2 | NodeprtInputTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1 | NodeprtInputEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.2 | Scalarprtinputtype | read-only | optional | The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.3 | Scalarprtinputdimunit | read-only | optional | The unit of measurement for use calculating and relaying dimensional values for this input sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.4 | Scalarprtinputmediadimfeeddirdeclared | read-write | optional | This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. Th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.5 | Scalarprtinputmediadimxfeeddirdeclared | read-write | optional | This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-un… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.6 | Scalarprtinputmediadimfeeddirchosen | read-only | optional | The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.7 | Scalarprtinputmediadimxfeeddirchosen | read-only | optional | The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.8 | Scalarprtinputcapacityunit | read-only | optional | The unit of measurement for use in calculating and relaying capacity values for this input sub-unit. Additional information: A sheet is a single piece of 20 po… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.9 | Scalarprtinputmaxcapacity | read-only | optional | The maximum capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this val… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.10 | Scalarprtinputcurrentlevel | read-only | optional | The current capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). If this input sub-unit can reliably sense this value, the value is … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.11 | Scalarprtinputstatus | read-only | optional | The current status of this input sub-unit. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Tr… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.12 | Scalarprtinputmedianame | read-write | optional | A description of the media contained in this input sub-unit; This description is intended for display to a human operator. This description is not processed by… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.13 | Scalarprtinputname | read-only | optional | The name assigned to this input sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.14 | Scalarprtinputvendorname | read-only | optional | The vendor name of this input sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.15 | Scalarprtinputmodel | read-only | optional | The model name of this input sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.16 | Scalarprtinputversion | read-only | optional | The version of this input sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.17 | Scalarprtinputserialnumber | read-only | optional | The serial number assigned to this input sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.18 | Scalarprtinputdescription | read-only | optional | A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization. Additional information: |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.19 | Scalarprtinputsecurity | read-only | optional | Indicates if this input sub-unit has some security associated with it. Additional information: No security mechanism provided. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9 | NodeprtOutput | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2 | NodeprtOutputTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1 | NodeprtOutputEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.2 | Scalarprtoutputtype | read-only | optional | The type of technology supported by this output sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.3 | Scalarprtoutputcapacityunit | read-only | optional | The unit of measurement for use in calculating and relaying capacity values for this output sub-unit. Additional information: A sheet is a single piece of 20 p… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.4 | Scalarprtoutputmaxcapacity | read-only | optional | The maximum capacity of this output sub-unit in output sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5 | Scalarprtoutputremainingcapacity | read-only | optional | The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (CapacityUnit) of this output sub-unit. If this output sub-un… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.6 | Scalarprtoutputstatus | read-only | optional | The current status of this output sub-unit. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and T… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.7 | Scalarprtoutputname | read-write | optional | The name assigned to this output sub-unit. Additional information: The characters must be in the range 20H to 7FH except 5C cannot be used. When this string is… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.8 | Scalarprtoutputvendorname | read-only | optional | The vendor name of this output sub-unit. Additional information: |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.9 | Scalarprtoutputmodel | read-only | optional | The name assigned to this output sub-unit. Additional information: The value returned by Tlatoani depends on the current mode of the device. The possible value… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.10 | Scalarprtoutputversion | read-only | optional | The version of this output sub-unit. Additional information: Returns device-specific information about the configuration of the output bin. May include informa… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.11 | Scalarprtoutputserialnumber | read-only | optional | The serial number assigned to this output sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.12 | Scalarprtoutputdescription | read-only | optional | A free-form text description of this output sub-unit in the localization specified by prtGeneralCurrentLocalization. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.13 | Scalarprtoutputsecurity | read-only | optional | Indicates if this output sub-unit has some security associated with it and if that security is enabled or not. Additional information: No security mechanism pr… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.19 | Scalarprtoutputstackingorder | read-only | optional | The current state of the stacking order for the associated output sub-unit. `FirstToLast' means that as pages are output the front of the next page is placed a… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.20 | Scalarprtoutputpagedeliveryorientation | read-only | optional | The reading surface that will be `up' when pages are delivered to the associated output sub-unit. Values are Face-Up and Face-Down. (Note: interpretation of th… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.21 | Scalarprtoutputbursting | read-only | optional | This object indicates that the outputing sub-unit supports bursting, and if so, whether the feature is enabled. Bursting is the process by which continuous med… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.22 | Scalarprtoutputdecollating | read-only | optional | This object indicates that the output supports supports decollating, and if so, whether the feature is enabled. Decollating is the process by which the individ… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.23 | Scalarprtoutputpagecollated | read-only | optional | This object indicates that the output sub-unit supports page collation, and if so, whether the feature is enabled. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.24 | Scalarprtoutputoffsetstacking | read-only | optional | This object indicates that the output supports supports offset stacking, and if so, whether the feature is enabled. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10 | NodeprtMarker | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2 | NodeprtMarkerTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1 | NodeprtMarkerEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.2 | Scalarprtmarkermarktech | read-only | optional | The type of marking technology used for this marking sub-unit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.3 | Scalarprtmarkercounterunit | read-only | optional | The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a s… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.4 | Scalarprtmarkerlifecount | read-only | optional | The count of the number of units of measure counted during the life of printer using units of measure as specified by CounterUnit. Additional information: In L… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.5 | Scalarprtmarkerpoweroncount | read-only | optional | The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by CounterUnit. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.6 | Scalarprtmarkerprocesscolorants | read-only | optional | The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and SpotColorants cannot both be 0. Mu… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.7 | Scalarprtmarkerspotcolorants | read-only | optional | The number of spot colors supported by this marker. The value of this object and ProcessColorants cannot both be 0. Must be 0 or greater. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.8 | Scalarprtmarkeraddressabilityunit | read-only | optional | The unit of measure of distances. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.9 | Scalarprtmarkeraddressabilityfeeddir | read-only | optional | The number of addressable marking positions in the feed direction per 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' o… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.10 | Scalarprtmarkeraddressabilityxfeeddir | read-only | optional | The number of addressable marking positions in the cross feed direction in 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'oth… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.11 | Scalarprtmarkernorthmargin | read-only | optional | The margin, in units identified by AddressabilityUnit, from the leading edge of the medium as the medium flows throught the marking engine with the side to be … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.12 | Scalarprtmarkersouthmargin | read-only | optional | The margin from the South edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.13 | Scalarprtmarkerwestmargin | read-only | optional | The margin from the West edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bouned by all four margins is… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.14 | Scalarprtmarkereastmargin | read-only | optional | The margin from the East edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins i… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.10.2.1.15 | Scalarprtmarkerstatus | read-only | optional | The current status of this marker sub-unit. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and T… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11 | NodeprtMarkerSupplies | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1 | NodeprtMarkerSuppliesTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1 | NodeprtMarkerSuppliesEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.2 | Scalarprtmarkersuppliesmarkerindex | read-only | optional | The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.3 | Scalarprtmarkersuppliescolorantindex | read-only | optional | The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no co… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.4 | Scalarprtmarkersuppliesclass | read-only | optional | Indicates whether this supply entity represents a supply container that is consumed or a receptacle that is filled. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.5 | Scalarprtmarkersuppliestype | read-only | optional | The type of this supply. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.6 | Scalarprtmarkersuppliesdescription | read-only | optional | The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.7 | Scalarprtmarkersuppliessupplyunit | read-only | optional | Unit of this marker supply container/receptacle. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.8 | Scalarprtmarkersuppliesmaxcapacity | read-only | optional | The maximum capacity of this supply container/receptacle expressed in SupplyUnit. If this supply container/receptacle can reliably sense this value, the value … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.9 | Scalarprtmarkersupplieslevel | read-only | optional | The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense thi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13 | NodeprtMediaPath | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4 | NodeprtMediaPathTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1 | NodeprtMediaPathEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.2 | Scalarprtmediapathmaxspeedprintunit | read-only | optional | The unit of measure used in specifying the speed of all media paths in the printer. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.3 | Scalarprtmediapathmediasizeunit | read-only | optional | The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.4 | Scalarprtmediapathmaxspeed | read-only | optional | The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'. Additional information: The page size f… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.5 | Scalarprtmediapathmaxmediafeeddir | read-only | optional | The maximum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-1) implies 'unl… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.6 | Scalarprtmediapathmaxmediaxfeeddir | read-only | optional | The maximum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.7 | Scalarprtmediapathminmediafeeddir | read-only | optional | The minimum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unk… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.8 | Scalarprtmediapathminmediaxfeeddir | read-only | optional | The minimum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.9 | Scalarprtmediapathtype | read-only | optional | The type of the media path for this media path. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.10 | Scalarprtmediapathdescription | read-only | optional | The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.13.4.1.11 | Scalarprtmediapathstatus | read-only | optional | The current status of this media path. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14 | NodeprtChannel | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1 | NodeprtChannelTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1 | NodeprtChannelEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.2 | Scalarprtchanneltype | read-only | optional | The type of this print data channel. This object provides the linkage to ChannelType-specific groups that may (conceptually) extend the prtChannelTable with ad… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.3 | Scalarprtchannelprotocolversion | read-only | optional | The version of the protocol used on this channel. The format used for version numbering depends on prtChannelType. Additional information: MIO-based channels p… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.4 | Scalarprtchannelcurrentjobcntllangindex | read-only | optional | The value of prtInterpreterIndex corresponding to the Control Language Interpreter for this channel. This interpreter defines the syntax used for control funct… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.5 | Scalarprtchanneldefaultpagedesclangindex | read-write | optional | The value of prtInterpreterIndex corresponding to the Page Description Language Interpreter for this channel. This interpreter defines the default Page Descrip… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.6 | Scalarprtchannelstate | read-only | optional | The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not. Additional inform… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.7 | Scalarprtchannelifindex | read-only | optional | The value of ifIndex (in the ifTable; see the interface section of MIB-2/RFC 1213) which corresponds to this channel. When more than one row of the ifTable is … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.14.1.1.8 | Scalarprtchannelstatus | read-only | optional | The current status of the channel. The status is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transition… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15 | NodeprtInterpreter | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1 | NodeprtInterpreterTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1 | NodeprtInterpreterEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.2 | Scalarprtinterpreterlangfamily | read-only | optional | The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate. This type 2 list of en… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.3 | Scalarprtinterpreterlanglevel | read-only | optional | The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.4 | Scalarprtinterpreterlangversion | read-only | optional | The date code or version of the language which this interpreter is interpreting or emulating. Additional information: For PostScript, this is more detailed rev… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.5 | Scalarprtinterpreterdescription | read-only | optional | A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.6 | Scalarprtinterpreterversion | read-only | optional | The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.7 | Scalarprtinterpreterdefaultorientation | read-write | optional | The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream). Addition… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.8 | Scalarprtinterpreterfeedaddressability | read-only | optional | The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityFeedDir ) for this interpreter.… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.9 | Scalarprtinterpreterxfeedaddressability | read-only | optional | The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityXFeedDir) for this interp… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.10 | Scalarprtinterpreterdefaultcharsetin | read-write | optional | The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the oct… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.11 | Scalarprtinterpreterdefaultcharsetout | read-only | optional | The default character set for data coming from this interpreter through the printer's output channel. This value shall be (2) if there is no default. Additiona… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.15.1.1.12 | Scalarprtinterpretertwoway | read-only | optional | Indicates whether or not this interpreter returns information back to the host. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16 | NodeprtConsoleDisplayBuffer | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5 | NodeprtConsoleDisplayBufferTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5.1 | NodeprtConsoleDisplayBufferEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.16.5.1.2 | Scalarprtconsoledisplaybuffertext | read-write | optional | The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to on… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17 | NodeprtConsoleLights | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6 | NodeprtConsoleLightTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1 | NodeprtConsoleLightEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.2 | Scalarprtconsoleontime | read-only | optional | The on time in milliseconds of blinking of this light; 0 indicates off always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always o… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.3 | Scalarprtconsoleofftime | read-only | optional | The off time in milliseconds of blinking of this light; 0 indicates on always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always o… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.4 | Scalarprtconsolecolor | read-only | optional | The color of this light. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.17.6.1.5 | Scalarprtconsoledescription | read-only | optional | The vendor description or label of this light in the localization specified by prtConsoleLocalization. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18 | NodeprtAlert | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1 | NodeprtAlertTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1 | NodeprtAlertEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.2 | Scalarprtalertseveritylevel | read-only | optional | The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table. |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.3 | Scalarprtalerttraininglevel | read-only | optional | The level of training required to handle this alert. The training level is an enumeration that is determined and assigned by the printer manufacturer based on … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.4 | Scalarprtalertgroup | read-only | optional | The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of ty… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.5 | Scalarprtalertgroupindex | read-only | optional | An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the printer that caused this alert. The… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.6 | Scalarprtalertlocation | read-only | optional | The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is … |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.7 | Scalarprtalertcode | read-only | optional | The code that describes the type of alert for this entry in the table. There are different codes for each sub-unit type: for example, Media Supply Low and Medi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.8 | Scalarprtalertdescription | read-only | optional | A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by the printer to further elabora… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3 | Nodehrm | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2 | NodehrStorage | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.2 | Scalarhrmemorysize | read-only | mandatory | The amount of physical main memory contained by the host. Additional information: The unit of measure for this object is 1024 bytes. The default value assumes … |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3 | NodehrStorageTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1 | NodehrStorageEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.1 | Scalarhrstorageindex | read-only | mandatory | A unique value for each logical storage area contained by the host. |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.2 | Scalarhrstoragetype | read-only | mandatory | The type of storage represented by this entry. |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.3 | Scalarhrstoragedescr | read-only | mandatory | A description of the type and instance of the storage described by this entry. Additional information: This object is not localized. |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.4 | Scalarhrstorageallocationunits | read-only | mandatory | The size, in bytes, of the data objects allocated from this pool. If this entry is monitoring sectors, blocks, buffers, or packets, for example, this number wi… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.5 | Scalarhrstoragesize | read-only | mandatory | The size of the storage represented by this entry, in units of hrStorageAllocationUnits. Additional information: Total formatter RAM. |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.6 | Scalarhrstorageused | read-only | mandatory | The amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits. Additional information: This object should not be … |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.2.3.1.7 | Scalarhrstorageallocationfailures | read-only | mandatory | The number of requests for storage represented by this entry that could not be honored due to not enough storage. It should be noted that as this object has a … |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3 | NodehrDevice | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2 | NodehrDeviceTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1 | NodehrDeviceEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.1 | Scalarhrdeviceindex | read-only | mandatory | A unique value for each device contained by the host. The value for each device must remain constant at least from one re-initialization of the agent to the ne… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.2 | Scalarhrdevicetype | read-only | mandatory | An indication of the type of device. If this value is `hrDeviceProcessor { hrDeviceTypes 3 }' then an entry exists in the hrProcessorTable which corresponds to… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.3 | Scalarhrdevicedescr | read-only | mandatory | A textual description of this device, including the device's manufacturer and revision, and optionally, its serial number. Additional information: This object … |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.4 | Scalarhrdeviceid | read-only | mandatory | The product ID for this device. Additional information: The complete OID reported by this object is: .1.3.6.1.4.1.11.2.3.9.1.2.1 |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.5 | Scalarhrdevicestatus | read-only | mandatory | The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current state of the device is unknown. r… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6 | Scalarhrdeviceerrors | read-only | mandatory | The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. Ho… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5 | NodehrPrinterTable | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1 | NodehrPrinterEntry | |||
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1.1 | Scalarhrprinterstatus | read-only | mandatory | The current status of this printer device. When in the idle(1), printing(2), or warmup(3) state, the corresponding hrDeviceStatus should be running(2) or warni… |
| 1.3.6.1.4.1.11.2.3.9.4.2.3.3.5.1.2 | Scalarhrprinterdetectederrorstate | read-only | mandatory | This object represents any error conditions detected by the printer. The error conditions are encoded as bits in an octet string, with the following definition… |