MBG-SNMP-LT-MIB

367 objects
Meinberg SNMP Management Information Base
Imported Objects
MBG-SNMP-ROOT-MIBmbgSnmpRoot
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.5597.3IdentitymbgLantimeMeinberg SNMP Management Information Base
1.3.6.1.4.1.5597.3.0NodembgLtInfo
1.3.6.1.4.1.5597.3.0.1ScalarmbgLtFirmwareVersionread-onlycurrentshows the installed firmware version of your LANTIME
1.3.6.1.4.1.5597.3.0.2ScalarmbgLtFirmwareVersionValread-onlycurrentshows the installed firmware version of your LANTIME as an Integer32 value
1.3.6.1.4.1.5597.3.1NodembgLtNtp
1.3.6.1.4.1.5597.3.1.1ScalarmbgLtNtpCurrentStateread-onlycurrentactual state of the NTP as string
1.3.6.1.4.1.5597.3.1.2ScalarmbgLtNtpCurrentStateValread-onlycurrentcurrent state of the NTP as Integer32 value
1.3.6.1.4.1.5597.3.1.3ScalarmbgLtNtpStratumread-onlycurrentStratum value of the NTP
1.3.6.1.4.1.5597.3.1.4ScalarmbgLtNtpActiveRefclockIdread-onlycurrentIndex of the current refclock selected by the NTP
1.3.6.1.4.1.5597.3.1.5ScalarmbgLtNtpActiveRefclockNameread-onlycurrentName of the current refclock selected by the NTP
1.3.6.1.4.1.5597.3.1.6ScalarmbgLtNtpActiveRefclockOffsetread-onlycurrentTime offset between the current selected refclock and time of NTP as string
1.3.6.1.4.1.5597.3.1.7ScalarmbgLtNtpActiveRefclockOffsetValread-onlycurrentTime offset in micro seconds between the current selected refclock and time of NTP
1.3.6.1.4.1.5597.3.1.8ScalarmbgLtNtpNumberOfRefclocksread-onlycurrentNumber of refclocks configured in the NTP
1.3.6.1.4.1.5597.3.1.9ScalarmbgLtNtpAuthKeyIdread-onlycurrentAuthentication Key ID of active refclock is active
1.3.6.1.4.1.5597.3.1.10ScalarmbgLtNtpVersionread-onlycurrentintegrated NTP version
1.3.6.1.4.1.5597.3.2NodembgLtRefclock
1.3.6.1.4.1.5597.3.2.1ScalarmbgLtRefClockTyperead-onlycurrentType of refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.2ScalarmbgLtRefClockTypeValread-onlycurrentType of refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.3ScalarmbgLtRefClockModeread-onlycurrentcurrent mode of refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.4ScalarmbgLtRefClockModeValread-onlycurrentcurrent mode of refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.5ScalarmbgLtRefGpsStateread-onlycurrentcurrent State of GPS refclock conneted to NTP time server
1.3.6.1.4.1.5597.3.2.6ScalarmbgLtRefGpsStateValread-onlycurrentcurrent State of GPS refclock conneted to NTP time server as value
1.3.6.1.4.1.5597.3.2.7ScalarmbgLtRefGpsPositionread-onlycurrentcurrent Position of GPS refclock conneted to NTP time server
1.3.6.1.4.1.5597.3.2.8ScalarmbgLtRefGpsSatellitesread-onlycurrentcurrent Satellites in view and good of GPS refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.9ScalarmbgLtRefGpsSatellitesGoodread-onlycurrentcurrent good Satellites of GPS refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.10ScalarmbgLtRefGpsSatellitesInViewread-onlycurrentcurrent Satellites in view of GPS refclock conneted to NTP time server as value
1.3.6.1.4.1.5597.3.2.11ScalarmbgLtRefPzfStateread-onlycurrentcurrent State of DCF77/PZF refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.12ScalarmbgLtRefPzfStateValread-onlycurrentcurrent State of DCF77/PZF refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.13ScalarmbgLtRefPzfKorrelationread-onlycurrentcurrent Korrelation of DCF77/PZF refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.14ScalarmbgLtRefPzfFieldread-onlycurrentcurrent strength of field of DCF77/PZF refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.15ScalarmbgLtRefGpsModeread-onlycurrentcurrent Mode of GPS refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.16ScalarmbgLtRefGpsModeValread-onlycurrentcurrent Mode of GPS refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.17ScalarmbgLtRefIrigModeread-onlycurrentcurrent Mode of IRIG refclock conneted to NTP time server
1.3.6.1.4.1.5597.3.2.18ScalarmbgLtRefIrigModeValread-onlycurrentcurrent Mode of IRIG refclock conneted to NTP time server as value
1.3.6.1.4.1.5597.3.2.19ScalarmbgLtRefPzfModeread-onlycurrentcurrent Mode of PZF refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.20ScalarmbgLtRefPzfModeValread-onlycurrentcurrent Mode of PZF refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.21ScalarmbgLtRefIrigStateread-onlycurrentcurrent State of IRIG refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.22ScalarmbgLtRefIrigStateValread-onlycurrentcurrent State of IRIG refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.23ScalarmbgLtRefSHSModeread-onlycurrentcurrent Mode of SHS system connected to NTP time server
1.3.6.1.4.1.5597.3.2.24ScalarmbgLtRefSHSModeValread-onlycurrentcurrent Mode of SHS system connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.25ScalarmbgLtRefSHSTimeDiffread-onlycurrentcurrent time difference between the two SHS reference time sources in miliseconds
1.3.6.1.4.1.5597.3.2.26ScalarmbgLtRefDctStateread-onlycurrentcurrent State of DCF77 refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.27ScalarmbgLtRefDctStateValread-onlycurrentcurrent State of DCF77 refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.28ScalarmbgLtRefDctFieldread-onlycurrentcurrent strength of field of DCF77 refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.29ScalarmbgLtRefDctModeread-onlycurrentcurrent Mode of DCF77 refclock connected to NTP time server
1.3.6.1.4.1.5597.3.2.30ScalarmbgLtRefDctModeValread-onlycurrentcurrent Mode of DCF77 refclock connected to NTP time server as value
1.3.6.1.4.1.5597.3.2.31ScalarmbgLtRefGpsLeapSecondread-onlycurrentDate and Time of leap second announcement received via GPS
1.3.6.1.4.1.5597.3.2.32ScalarmbgLtRefGpsLeapCorrectionread-onlycurrentLeap Second Correction received via GPS
1.3.6.1.4.1.5597.3.2.50NodembgLtMrs
1.3.6.1.4.1.5597.3.2.50.1ScalarmbgLtRefMrsRefread-onlycurrentID of currently active reference source as a string
1.3.6.1.4.1.5597.3.2.50.2ScalarmbgLtRefMrsRefValread-onlycurrentcurrently active reference as a value
1.3.6.1.4.1.5597.3.2.50.3ScalarmbgLtRefMrsRefListread-onlycurrentList of all supported MRS references in a comma separated list
1.3.6.1.4.1.5597.3.2.50.4ScalarmbgLtRefMrsPrioListread-onlycurrentList of all active MRS references in a comma separated list sorted by priority
1.3.6.1.4.1.5597.3.2.50.10NodembgLtMrsRef
1.3.6.1.4.1.5597.3.2.50.10.1NodembgLtMrsRefGps
1.3.6.1.4.1.5597.3.2.50.10.1.1ScalarmbgLtMrsGpsOffsread-onlycurrentOffset of this reference to the currently active reference, unit included in the string
1.3.6.1.4.1.5597.3.2.50.10.1.2ScalarmbgLtMrsGpsOffsValread-onlycurrentOffset of this reference to the currently active reference, unit see below
1.3.6.1.4.1.5597.3.2.50.10.1.3ScalarmbgLtMrsGpsOffsBaseread-onlycurrentbase of the offset value shown in mbgLtMrsGpsOffsVal
1.3.6.1.4.1.5597.3.2.50.10.1.4ScalarmbgLtMrsGpsPrioread-onlycurrentthe configured priority of this reference
1.3.6.1.4.1.5597.3.2.50.10.1.5ScalarmbgLtMrsGpsStateread-onlycurrentthe current status of this reference as a string
1.3.6.1.4.1.5597.3.2.50.10.1.6ScalarmbgLtMrsGpsStateValread-onlycurrentthe current status of this reference as an Integer value
1.3.6.1.4.1.5597.3.2.50.10.1.7ScalarmbgLtMrsGpsPrecisionread-writecurrentPrecision Factor of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.2NodembgLtMrsRefIrig
1.3.6.1.4.1.5597.3.2.50.10.2.1ScalarmbgLtMrsIrigOffsread-onlycurrentOffset of this reference to the currently active reference, unit included in the string
1.3.6.1.4.1.5597.3.2.50.10.2.2ScalarmbgLtMrsIrigOffsValread-onlycurrentOffset of this reference to the currently active reference, unit see below
1.3.6.1.4.1.5597.3.2.50.10.2.3ScalarmbgLtMrsIrigOffsBaseread-onlycurrentbase of the offset value shown in mbgLtMrsIrigOffsVal
1.3.6.1.4.1.5597.3.2.50.10.2.4ScalarmbgLtMrsIrigPrioread-onlycurrentthe configured priority of this reference
1.3.6.1.4.1.5597.3.2.50.10.2.5ScalarmbgLtMrsIrigStateread-onlycurrentthe current status of this reference as a string
1.3.6.1.4.1.5597.3.2.50.10.2.6ScalarmbgLtMrsIrigStateValread-onlycurrentthe current status of this reference as an Integer value
1.3.6.1.4.1.5597.3.2.50.10.2.7ScalarmbgLtMrsIrigCorrread-writecurrentCorrection Value (Fixed Offset) of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.2.8ScalarmbgLtMrsIrigOffsLimitread-writecurrentOffset Limit in nanoseconds, if exceeded this will trigger a notification
1.3.6.1.4.1.5597.3.2.50.10.2.9ScalarmbgLtMrsIrigPrecisionread-writecurrentPrecision Factor of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.3NodembgLtMrsRefPps
1.3.6.1.4.1.5597.3.2.50.10.3.1ScalarmbgLtMrsPpsOffsread-onlycurrentOffset of this reference to the currently active reference, unit included in the string
1.3.6.1.4.1.5597.3.2.50.10.3.2ScalarmbgLtMrsPpsOffsValread-onlycurrentOffset of this reference to the currently active reference, unit see below
1.3.6.1.4.1.5597.3.2.50.10.3.3ScalarmbgLtMrsPpsOffsBaseread-onlycurrentbase of the offset value shown in mbgLtMrsPpsOffsVal
1.3.6.1.4.1.5597.3.2.50.10.3.4ScalarmbgLtMrsPpsPrioread-onlycurrentthe configured priority of this reference
1.3.6.1.4.1.5597.3.2.50.10.3.5ScalarmbgLtMrsPpsStateread-onlycurrentthe current status of this reference as a string
1.3.6.1.4.1.5597.3.2.50.10.3.6ScalarmbgLtMrsPpsStateValread-onlycurrentthe current status of this reference as an Integer value
1.3.6.1.4.1.5597.3.2.50.10.3.7ScalarmbgLtMrsPpsCorrread-writecurrentCorrection Value (Fixed Offset) of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.3.8ScalarmbgLtMrsPpsOffsLimitread-writecurrentOffset Limit in nanoseconds, if exceeded this will trigger a notification
1.3.6.1.4.1.5597.3.2.50.10.3.9ScalarmbgLtMrsPpsPrecisionread-writecurrentPrecision Factor of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.4NodembgLtMrsRefFreq
1.3.6.1.4.1.5597.3.2.50.10.4.1ScalarmbgLtMrsFreqOffsread-onlycurrentOffset of this reference to the currently active reference, unit included in the string
1.3.6.1.4.1.5597.3.2.50.10.4.2ScalarmbgLtMrsFreqOffsValread-onlycurrentOffset of this reference to the currently active reference, unit see below
1.3.6.1.4.1.5597.3.2.50.10.4.3ScalarmbgLtMrsFreqOffsBaseread-onlycurrentbase of the offset value shown in mbgLtMrsFreqOffsVal
1.3.6.1.4.1.5597.3.2.50.10.4.4ScalarmbgLtMrsFreqPrioread-onlycurrentthe configured priority of this reference
1.3.6.1.4.1.5597.3.2.50.10.4.5ScalarmbgLtMrsFreqStateread-onlycurrentthe current status of this reference as a string
1.3.6.1.4.1.5597.3.2.50.10.4.6ScalarmbgLtMrsFreqStateValread-onlycurrentthe current status of this reference as an Integer value
1.3.6.1.4.1.5597.3.2.50.10.4.7ScalarmbgLtMrsFreqCorrread-writecurrentCorrection Value (Fixed Offset) of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.4.8ScalarmbgLtMrsFreqOffsLimitread-writecurrentOffset Limit in nanoseconds, if exceeded this will trigger a notification
1.3.6.1.4.1.5597.3.2.50.10.4.9ScalarmbgLtMrsFreqPrecisionread-writecurrentPrecision Factor of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.5NodembgLtMrsRefPtp
1.3.6.1.4.1.5597.3.2.50.10.5.1ScalarmbgLtMrsPtpOffsread-onlycurrentOffset of this reference to the currently active reference, unit included in the string
1.3.6.1.4.1.5597.3.2.50.10.5.2ScalarmbgLtMrsPtpOffsValread-onlycurrentOffset of this reference to the currently active reference, unit see below
1.3.6.1.4.1.5597.3.2.50.10.5.3ScalarmbgLtMrsPtpOffsBaseread-onlycurrentbase of the offset value shown in mbgLtMrsPtpOffsVal
1.3.6.1.4.1.5597.3.2.50.10.5.4ScalarmbgLtMrsPtpPrioread-onlycurrentthe configured priority of this reference
1.3.6.1.4.1.5597.3.2.50.10.5.5ScalarmbgLtMrsPtpStateread-onlycurrentthe current status of this reference as a string
1.3.6.1.4.1.5597.3.2.50.10.5.6ScalarmbgLtMrsPtpStateValread-onlycurrentthe current status of this reference as an Integer value
1.3.6.1.4.1.5597.3.2.50.10.5.7ScalarmbgLtMrsPtpCorrread-writecurrentCorrection Value (Fixed Offset) of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.5.8ScalarmbgLtMrsPtpOffsLimitread-writecurrentOffset Limit in nanoseconds, if exceeded this will trigger a notification
1.3.6.1.4.1.5597.3.2.50.10.5.9ScalarmbgLtMrsPtpPrecisionread-writecurrentPrecision Factor of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.6NodembgLtMrsRefNtp
1.3.6.1.4.1.5597.3.2.50.10.6.1ScalarmbgLtMrsNtpOffsread-onlycurrentOffset of this reference to the currently active reference, unit included in the string
1.3.6.1.4.1.5597.3.2.50.10.6.2ScalarmbgLtMrsNtpOffsValread-onlycurrentOffset of this reference to the currently active reference, unit see below
1.3.6.1.4.1.5597.3.2.50.10.6.3ScalarmbgLtMrsNtpOffsBaseread-onlycurrentbase of the offset value shown in mbgLtMrsNtpOffsVal
1.3.6.1.4.1.5597.3.2.50.10.6.4ScalarmbgLtMrsNtpPrioread-onlycurrentthe configured priority of this reference
1.3.6.1.4.1.5597.3.2.50.10.6.5ScalarmbgLtMrsNtpStateread-onlycurrentthe current status of this reference as a string
1.3.6.1.4.1.5597.3.2.50.10.6.6ScalarmbgLtMrsNtpStateValread-onlycurrentthe current status of this reference as an Integer value
1.3.6.1.4.1.5597.3.2.50.10.6.7ScalarmbgLtMrsNtpCorrread-writecurrentCorrection Value (Fixed Offset) of this reference in nanoseconds
1.3.6.1.4.1.5597.3.2.50.10.6.8ScalarmbgLtMrsNtpOffsLimitread-writecurrentOffset Limit in nanoseconds, if exceeded this will trigger a notification
1.3.6.1.4.1.5597.3.2.50.10.6.9ScalarmbgLtMrsNtpPrecisionread-writecurrentPrecision Factor of this reference in nanoseconds
1.3.6.1.4.1.5597.3.3NodembgLtNotifications
1.3.6.1.4.1.5597.3.3.0NodembgLtTraps
1.3.6.1.4.1.5597.3.3.0.1NotificationmbgLtTrapNTPNotSynccurrenttrap to be sent when NTP is not synchronised
1.3.6.1.4.1.5597.3.3.0.2NotificationmbgLtTrapNTPStoppedcurrenttrap to be sent when NTP is stopped
1.3.6.1.4.1.5597.3.3.0.3NotificationmbgLtTrapServerBootcurrenttrap to be sent when time server has finished boot sequence
1.3.6.1.4.1.5597.3.3.0.4NotificationmbgLtTrapReceiverNotRespondingcurrenttrap to be sent when receiver is not responding
1.3.6.1.4.1.5597.3.3.0.5NotificationmbgLtTrapReceiverNotSynccurrenttrap to be sent when receiver is not synchronised
1.3.6.1.4.1.5597.3.3.0.6NotificationmbgLtTrapAntennaFaultycurrenttrap to be sent when connection to antenna is broken
1.3.6.1.4.1.5597.3.3.0.7NotificationmbgLtTrapAntennaReconnectcurrenttrap to be sent when antenna has been reconnected
1.3.6.1.4.1.5597.3.3.0.8NotificationmbgLtTrapConfigChangedcurrenttrap to be sent when timeserver reloaded its configuration
1.3.6.1.4.1.5597.3.3.0.9NotificationmbgLtTrapLeapSecondAnnouncedcurrenttrap to be sent when a leap second has been announced
1.3.6.1.4.1.5597.3.3.0.10NotificationmbgLtTrapSHSTimeLimitErrorcurrenttrap to be sent when SHS timelimit exceeded
1.3.6.1.4.1.5597.3.3.0.11NotificationmbgLtTrapSecondaryRecNotSynccurrenttrap to be sent when secondary receiver in SHS system is not synchronised
1.3.6.1.4.1.5597.3.3.0.12NotificationmbgLtTrapPowerSupplyFailurecurrenttrap to be sent when one of the redundant power supplies fails
1.3.6.1.4.1.5597.3.3.0.13NotificationmbgLtTrapAntennaShortCircuitcurrenttrap to be sent when a connected antenna fails due to a short circuit
1.3.6.1.4.1.5597.3.3.0.14NotificationmbgLtTrapReceiverSynccurrenttrap to be sent when receiver is synchronised
1.3.6.1.4.1.5597.3.3.0.15NotificationmbgLtTrapNTPClientAlarmcurrenttrap to be sent when an NTP Client Monitoring alarm occurs, e.g. when a monitored client is not reachable.
1.3.6.1.4.1.5597.3.3.0.16NotificationmbgLtTrapPowerSupplyUpcurrenttrap to be sent when a power supply returned to a healthy state.
1.3.6.1.4.1.5597.3.3.0.17NotificationmbgLtTrapNetworkDowncurrenttrap to be sent when a monitored network port is down.
1.3.6.1.4.1.5597.3.3.0.18NotificationmbgLtTrapNetworkUpcurrenttrap to be sent when a monitored network port is up.
1.3.6.1.4.1.5597.3.3.0.19NotificationmbgLtTrapSecondaryRecNotRespcurrenttrap to be sent when secondary receiver is not responding
1.3.6.1.4.1.5597.3.3.0.30NotificationmbgLtTrapXmrLimitExceededcurrenttrap to be sent when a reference offset exceeds the configured limit
1.3.6.1.4.1.5597.3.3.0.31NotificationmbgLtTrapXmrRefDisconnectcurrenttrap to be sent when a reference signal has been lost
1.3.6.1.4.1.5597.3.3.0.32NotificationmbgLtTrapXmrRefReconnectcurrenttrap to be sent when a reference signal recovered
1.3.6.1.4.1.5597.3.3.0.33NotificationmbgLtTrapFdmErrorcurrenttrap to be sent when the Fdm module generates an alarm
1.3.6.1.4.1.5597.3.3.0.34NotificationmbgLtTrapSHSTimeLimitWarningcurrenttrap to be sent when SHS warning limit exceeded
1.3.6.1.4.1.5597.3.3.0.35NotificationmbgLtTrapSecondaryRecSynccurrenttrap to be sent when secondary receiver is synchronised
1.3.6.1.4.1.5597.3.3.0.36NotificationmbgLtTrapNTPSynccurrenttrap to be sent when NTP is synchronised
1.3.6.1.4.1.5597.3.3.0.37NotificationmbgLtTrapPtpPortDisconnectedcurrenttrap to be sent when PTP network port got disconnected
1.3.6.1.4.1.5597.3.3.0.38NotificationmbgLtTrapPtpPortConnectedcurrenttrap to be sent when PTP network port got connected
1.3.6.1.4.1.5597.3.3.0.39NotificationmbgLtTrapPtpStateChangedcurrenttrap to be sent when PTP state changed (e.g. from 'passive' to 'master')
1.3.6.1.4.1.5597.3.3.0.40NotificationmbgLtTrapPtpErrorcurrenttrap to be sent when PTP raised an error
1.3.6.1.4.1.5597.3.3.0.77NotificationmbgLtTrapNormalOperationcurrenttrap to be sent when the system returned to a healthy state
1.3.6.1.4.1.5597.3.3.0.88NotificationmbgLtTrapHeartbeatcurrenttrap to be sent periodically to indicate that time server is still alive
1.3.6.1.4.1.5597.3.3.0.99NotificationmbgLtTrapTestNotificationcurrenttrap to be sent when a test notification has been requested
1.3.6.1.4.1.5597.3.3.0.100ScalarmbgLtTrapMessageread-onlycurrentused as a payload object for all traps, holds a clear text event message
1.3.6.1.4.1.5597.3.4NodembgLtCfg
1.3.6.1.4.1.5597.3.4.1NodembgLtCfgNetwork
1.3.6.1.4.1.5597.3.4.1.1ScalarmbgLtCfgHostnameread-writecurrentThe hostname configured for this LANTIME
1.3.6.1.4.1.5597.3.4.1.2ScalarmbgLtCfgDomainnameread-writecurrentThe domainname configured for this LANTIME
1.3.6.1.4.1.5597.3.4.1.3ScalarmbgLtCfgNameserver1read-writecurrentThe first nameserver used by this LANTIME
1.3.6.1.4.1.5597.3.4.1.4ScalarmbgLtCfgNameserver2read-writecurrentThe second nameserver used this LANTIME
1.3.6.1.4.1.5597.3.4.1.5ScalarmbgLtCfgSyslogserver1read-writecurrentThe first syslog server we are sending log entries to
1.3.6.1.4.1.5597.3.4.1.6ScalarmbgLtCfgSyslogserver2read-writecurrentThe second syslog server we are sending log entries to
1.3.6.1.4.1.5597.3.4.1.7ScalarmbgLtCfgTelnetAccessread-writecurrentIs telnet administration enabled
1.3.6.1.4.1.5597.3.4.1.8ScalarmbgLtCfgFTPAccessread-writecurrentIs FTP administration enabled
1.3.6.1.4.1.5597.3.4.1.9ScalarmbgLtCfgHTTPAccessread-writecurrentIs web based administration enabled
1.3.6.1.4.1.5597.3.4.1.10ScalarmbgLtCfgHTTPSAccessread-writecurrentIs secure web based administration enabled
1.3.6.1.4.1.5597.3.4.1.11ScalarmbgLtCfgSNMPAccessread-writecurrentIs SNMP administration enabled
1.3.6.1.4.1.5597.3.4.1.12ScalarmbgLtCfgSambaAccessread-writecurrentIs Samba administration enabled
1.3.6.1.4.1.5597.3.4.1.13ScalarmbgLtCfgIPv6Accessread-writecurrentIs IPv6 support enabled
1.3.6.1.4.1.5597.3.4.1.14ScalarmbgLtCfgSSHAccessread-writecurrentIs SSH administration enabled
1.3.6.1.4.1.5597.3.4.2NodembgLtCfgNTP
1.3.6.1.4.1.5597.3.4.2.1NodembgLtCfgNTPServer1
1.3.6.1.4.1.5597.3.4.2.1.1ScalarmbgLtCfgNTPServer1IPread-writecurrentIP address for external NTP server
1.3.6.1.4.1.5597.3.4.2.1.2ScalarmbgLtCfgNTPServer1Keyread-writecurrentKey for external NTP server
1.3.6.1.4.1.5597.3.4.2.1.3ScalarmbgLtCfgNTPServer1Autokeyread-writecurrentIs autokey enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.1.4ScalarmbgLtCfgNTPServer1Preferread-writecurrentIs the preferred flag enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.2NodembgLtCfgNTPServer2
1.3.6.1.4.1.5597.3.4.2.2.1ScalarmbgLtCfgNTPServer2IPread-writecurrentIP address for external NTP server
1.3.6.1.4.1.5597.3.4.2.2.2ScalarmbgLtCfgNTPServer2Keyread-writecurrentKey for external NTP server
1.3.6.1.4.1.5597.3.4.2.2.3ScalarmbgLtCfgNTPServer2Autokeyread-writecurrentIs autokey enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.2.4ScalarmbgLtCfgNTPServer2Preferread-writecurrentIs the preferred flag enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.3NodembgLtCfgNTPServer3
1.3.6.1.4.1.5597.3.4.2.3.1ScalarmbgLtCfgNTPServer3IPread-writecurrentIP address for external NTP server
1.3.6.1.4.1.5597.3.4.2.3.2ScalarmbgLtCfgNTPServer3Keyread-writecurrentKey for external NTP server
1.3.6.1.4.1.5597.3.4.2.3.3ScalarmbgLtCfgNTPServer3Autokeyread-writecurrentIs autokey enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.3.4ScalarmbgLtCfgNTPServer3Preferread-writecurrentIs the preferred flag enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.4NodembgLtCfgNTPServer4
1.3.6.1.4.1.5597.3.4.2.4.1ScalarmbgLtCfgNTPServer4IPread-writecurrentIP address for external NTP server
1.3.6.1.4.1.5597.3.4.2.4.2ScalarmbgLtCfgNTPServer4Keyread-writecurrentKey for external NTP server
1.3.6.1.4.1.5597.3.4.2.4.3ScalarmbgLtCfgNTPServer4Autokeyread-writecurrentIs autokey enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.4.4ScalarmbgLtCfgNTPServer4Preferread-writecurrentIs the preferred flag enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.5NodembgLtCfgNTPServer5
1.3.6.1.4.1.5597.3.4.2.5.1ScalarmbgLtCfgNTPServer5IPread-writecurrentIP address for external NTP server
1.3.6.1.4.1.5597.3.4.2.5.2ScalarmbgLtCfgNTPServer5Keyread-writecurrentKey for external NTP server
1.3.6.1.4.1.5597.3.4.2.5.3ScalarmbgLtCfgNTPServer5Autokeyread-writecurrentIs autokey enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.5.4ScalarmbgLtCfgNTPServer5Preferread-writecurrentIs the preferred flag enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.6NodembgLtCfgNTPServer6
1.3.6.1.4.1.5597.3.4.2.6.1ScalarmbgLtCfgNTPServer6IPread-writecurrentIP address for external NTP server
1.3.6.1.4.1.5597.3.4.2.6.2ScalarmbgLtCfgNTPServer6Keyread-writecurrentKey for external NTP server
1.3.6.1.4.1.5597.3.4.2.6.3ScalarmbgLtCfgNTPServer6Autokeyread-writecurrentIs autokey enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.6.4ScalarmbgLtCfgNTPServer6Preferread-writecurrentIs the preferred flag enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.7NodembgLtCfgNTPServer7
1.3.6.1.4.1.5597.3.4.2.7.1ScalarmbgLtCfgNTPServer7IPread-writecurrentIP address for external NTP server
1.3.6.1.4.1.5597.3.4.2.7.2ScalarmbgLtCfgNTPServer7Keyread-writecurrentKey for external NTP server
1.3.6.1.4.1.5597.3.4.2.7.3ScalarmbgLtCfgNTPServer7Autokeyread-writecurrentIs autokey enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.7.4ScalarmbgLtCfgNTPServer7Preferread-writecurrentIs the preferred flag enabled for the external NTP server
1.3.6.1.4.1.5597.3.4.2.8ScalarmbgLtCfgNTPStratumLocalClockread-writecurrentThe stratum value assigned to the local clock of the timeserver
1.3.6.1.4.1.5597.3.4.2.9ScalarmbgLtCfgNTPTrustedKeyread-writecurrentThe key used for the internal refclock of the timeserver
1.3.6.1.4.1.5597.3.4.2.10ScalarmbgLtCfgNTPBroadcastIPread-writecurrentNTP broadcast IP address
1.3.6.1.4.1.5597.3.4.2.11ScalarmbgLtCfgNTPBroadcastKeyread-writecurrentKey used for NTP broadcasts
1.3.6.1.4.1.5597.3.4.2.12ScalarmbgLtCfgNTPBroadcastAutokeyread-writecurrentIs autokey generation used for NTP broadcasts
1.3.6.1.4.1.5597.3.4.2.13ScalarmbgLtCfgNTPAutokeyFeatureread-writecurrentIs the NTP autokey feature enabled
1.3.6.1.4.1.5597.3.4.2.14ScalarmbgLtCfgNTPAtomPPSread-writecurrentIs the NTP atom pps feature enabled
1.3.6.1.4.1.5597.3.4.3NodembgLtCfgEMail
1.3.6.1.4.1.5597.3.4.3.1ScalarmbgLtCfgEMailToread-writecurrentEMail address to send alerts etc. to (receiving address)
1.3.6.1.4.1.5597.3.4.3.2ScalarmbgLtCfgEMailFromread-writecurrentEMail address to send alerts etc. from (sending address)
1.3.6.1.4.1.5597.3.4.3.3ScalarmbgLtCfgEMailSmarthostread-writecurrentSMTP smarthost used to send mail
1.3.6.1.4.1.5597.3.4.4NodembgLtCfgSNMP
1.3.6.1.4.1.5597.3.4.4.1ScalarmbgLtCfgSNMPTrapReceiver1read-writecurrentFirst SNMP trap receiver host
1.3.6.1.4.1.5597.3.4.4.2ScalarmbgLtCfgSNMPTrapReceiver2read-writecurrentSecond SNMP trap receiver host
1.3.6.1.4.1.5597.3.4.4.3ScalarmbgLtCfgSNMPTrapRec1Communityread-writecurrentFirst SNMP trap receiver community
1.3.6.1.4.1.5597.3.4.4.4ScalarmbgLtCfgSNMPTrapRec2Communityread-writecurrentSecond SNMP trap receiver community
1.3.6.1.4.1.5597.3.4.4.5ScalarmbgLtCfgSNMPReadOnlyCommunityread-writecurrentSNMP community string for read-only access
1.3.6.1.4.1.5597.3.4.4.6ScalarmbgLtCfgSNMPReadWriteCommunityread-writecurrentSNMP community string for read-write access
1.3.6.1.4.1.5597.3.4.4.7ScalarmbgLtCfgSNMPContactread-writecurrentSNMP contact string for Lantime
1.3.6.1.4.1.5597.3.4.4.8ScalarmbgLtCfgSNMPLocationread-writecurrentSNMP location string for Lantime
1.3.6.1.4.1.5597.3.4.5NodembgLtCfgWinpopup
1.3.6.1.4.1.5597.3.4.5.1ScalarmbgLtCfgWMailAddress1read-writecurrentFirst windows popup alert receiver
1.3.6.1.4.1.5597.3.4.5.2ScalarmbgLtCfgWMailAddress2read-writecurrentSecond windows popup alert receiver
1.3.6.1.4.1.5597.3.4.6NodembgLtCfgWalldisplay
1.3.6.1.4.1.5597.3.4.6.1ScalarmbgLtCfgVP100Display1IPread-writecurrentIP address of first VP100 wall display
1.3.6.1.4.1.5597.3.4.6.2ScalarmbgLtCfgVP100Display1SNread-writecurrentSerial number of first VP100 wall display
1.3.6.1.4.1.5597.3.4.6.3ScalarmbgLtCfgVP100Display2IPread-writecurrentIP address of second VP100 wall display
1.3.6.1.4.1.5597.3.4.6.4ScalarmbgLtCfgVP100Display2SNread-writecurrentSerial number of second VP100 wall display
1.3.6.1.4.1.5597.3.4.7NodembgLtCfgNotify
1.3.6.1.4.1.5597.3.4.7.1ScalarmbgLtCfgNotifyNTPNotSyncread-writecurrentWhich alerts are sent in case of a NTP_not_sync event
1.3.6.1.4.1.5597.3.4.7.2ScalarmbgLtCfgNotifyNTPStoppedread-writecurrentWhich alerts are sent in case of a NTP_stopped event
1.3.6.1.4.1.5597.3.4.7.3ScalarmbgLtCfgNotifyServerBootread-writecurrentWhich alerts are sent in case of a server_boot event
1.3.6.1.4.1.5597.3.4.7.4ScalarmbgLtCfgNotifyRefclkNoResponseread-writecurrentWhich alerts are sent in case of a refclock_not_responding event
1.3.6.1.4.1.5597.3.4.7.5ScalarmbgLtCfgNotifyRefclockNotSyncread-writecurrentWhich alerts are sent in case of a refclock_not_sync event
1.3.6.1.4.1.5597.3.4.7.6ScalarmbgLtCfgNotifyAntennaFaultyread-writecurrentWhich alerts are sent in case of an antenna_faulty event
1.3.6.1.4.1.5597.3.4.7.7ScalarmbgLtCfgNotifyAntennaReconnectread-writecurrentWhich alerts are sent in case of an antenna_reconnect event
1.3.6.1.4.1.5597.3.4.7.8ScalarmbgLtCfgNotifyConfigChangedread-writecurrentWhich alerts are sent in case of a config_changed event
1.3.6.1.4.1.5597.3.4.7.9ScalarmbgLtCfgNotifySHSTimeLimitErrorread-writecurrentWhich alerts are sent in case of a SHS_timelimiterror event
1.3.6.1.4.1.5597.3.4.7.10ScalarmbgLtCfgNotifyLeapSecondread-writecurrentWhich alerts are sent in case of a Leap_Second_Announced event
1.3.6.1.4.1.5597.3.4.8NodembgLtCfgEthernet
1.3.6.1.4.1.5597.3.4.8.0NodembgLtCfgEthernetIf0
1.3.6.1.4.1.5597.3.4.8.0.1ScalarmbgLtCfgEthernetIf0IPv4IPread-writecurrentThe IPv4 address of the first ethernet interface
1.3.6.1.4.1.5597.3.4.8.0.2ScalarmbgLtCfgEthernetIf0IPv4Netmaskread-writecurrentThe IPv4 netmask of the first ethernet interface
1.3.6.1.4.1.5597.3.4.8.0.3ScalarmbgLtCfgEthernetIf0IPv4Gatewayread-writecurrentThe IPv4 gateway address of the first ethernet interface
1.3.6.1.4.1.5597.3.4.8.0.4ScalarmbgLtCfgEthernetIf0DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.0.5ScalarmbgLtCfgEthernetIf0IPv6IP1read-writecurrentThe first IPv6 address of the first ethernet interface
1.3.6.1.4.1.5597.3.4.8.0.6ScalarmbgLtCfgEthernetIf0IPv6IP2read-writecurrentThe second IPv6 address of the first ethernet interface
1.3.6.1.4.1.5597.3.4.8.0.7ScalarmbgLtCfgEthernetIf0IPv6IP3read-writecurrentThe third IPv6 address of the first ethernet interface
1.3.6.1.4.1.5597.3.4.8.0.8ScalarmbgLtCfgEthernetIf0IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.0.9ScalarmbgLtCfgEthernetIf0NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.1NodembgLtCfgEthernetIf1
1.3.6.1.4.1.5597.3.4.8.1.1ScalarmbgLtCfgEthernetIf1IPv4IPread-writecurrentThe IPv4 address of the second ethernet interface
1.3.6.1.4.1.5597.3.4.8.1.2ScalarmbgLtCfgEthernetIf1IPv4Netmaskread-writecurrentThe IPv4 netmask of the second ethernet interface
1.3.6.1.4.1.5597.3.4.8.1.3ScalarmbgLtCfgEthernetIf1IPv4Gatewayread-writecurrentThe IPv4 gateway address of the second ethernet interface
1.3.6.1.4.1.5597.3.4.8.1.4ScalarmbgLtCfgEthernetIf1DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.1.5ScalarmbgLtCfgEthernetIf1IPv6IP1read-writecurrentThe first IPv6 address of the second ethernet interface
1.3.6.1.4.1.5597.3.4.8.1.6ScalarmbgLtCfgEthernetIf1IPv6IP2read-writecurrentThe second IPv6 address of the second ethernet interface
1.3.6.1.4.1.5597.3.4.8.1.7ScalarmbgLtCfgEthernetIf1IPv6IP3read-writecurrentThe third IPv6 address of the second ethernet interface
1.3.6.1.4.1.5597.3.4.8.1.8ScalarmbgLtCfgEthernetIf1IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.1.9ScalarmbgLtCfgEthernetIf1NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.2NodembgLtCfgEthernetIf2
1.3.6.1.4.1.5597.3.4.8.2.1ScalarmbgLtCfgEthernetIf2IPv4IPread-writecurrentThe IPv4 address of the third ethernet interface
1.3.6.1.4.1.5597.3.4.8.2.2ScalarmbgLtCfgEthernetIf2IPv4Netmaskread-writecurrentThe IPv4 netmask of the third ethernet interface
1.3.6.1.4.1.5597.3.4.8.2.3ScalarmbgLtCfgEthernetIf2IPv4Gatewayread-writecurrentThe IPv4 gateway address of the third ethernet interface
1.3.6.1.4.1.5597.3.4.8.2.4ScalarmbgLtCfgEthernetIf2DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.2.5ScalarmbgLtCfgEthernetIf2IPv6IP1read-writecurrentThe first IPv6 address of the third ethernet interface
1.3.6.1.4.1.5597.3.4.8.2.6ScalarmbgLtCfgEthernetIf2IPv6IP2read-writecurrentThe second IPv6 address of the third ethernet interface
1.3.6.1.4.1.5597.3.4.8.2.7ScalarmbgLtCfgEthernetIf2IPv6IP3read-writecurrentThe third IPv6 address of the third ethernet interface
1.3.6.1.4.1.5597.3.4.8.2.8ScalarmbgLtCfgEthernetIf2IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.2.9ScalarmbgLtCfgEthernetIf2NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.3NodembgLtCfgEthernetIf3
1.3.6.1.4.1.5597.3.4.8.3.1ScalarmbgLtCfgEthernetIf3IPv4IPread-writecurrentThe IPv4 address of the fourth ethernet interface
1.3.6.1.4.1.5597.3.4.8.3.2ScalarmbgLtCfgEthernetIf3IPv4Netmaskread-writecurrentThe IPv4 netmask of the fourth ethernet interface
1.3.6.1.4.1.5597.3.4.8.3.3ScalarmbgLtCfgEthernetIf3IPv4Gatewayread-writecurrentThe IPv4 gateway address of the fourth ethernet interface
1.3.6.1.4.1.5597.3.4.8.3.4ScalarmbgLtCfgEthernetIf3DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.3.5ScalarmbgLtCfgEthernetIf3IPv6IP1read-writecurrentThe first IPv6 address of the fourth ethernet interface
1.3.6.1.4.1.5597.3.4.8.3.6ScalarmbgLtCfgEthernetIf3IPv6IP2read-writecurrentThe second IPv6 address of the fourth ethernet interface
1.3.6.1.4.1.5597.3.4.8.3.7ScalarmbgLtCfgEthernetIf3IPv6IP3read-writecurrentThe third IPv6 address of the fourth ethernet interface
1.3.6.1.4.1.5597.3.4.8.3.8ScalarmbgLtCfgEthernetIf3IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.3.9ScalarmbgLtCfgEthernetIf3NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.4NodembgLtCfgEthernetIf4
1.3.6.1.4.1.5597.3.4.8.4.1ScalarmbgLtCfgEthernetIf4IPv4IPread-writecurrentThe IPv4 address of the fifth ethernet interface
1.3.6.1.4.1.5597.3.4.8.4.2ScalarmbgLtCfgEthernetIf4IPv4Netmaskread-writecurrentThe IPv4 netmask of the fifth ethernet interface
1.3.6.1.4.1.5597.3.4.8.4.3ScalarmbgLtCfgEthernetIf4IPv4Gatewayread-writecurrentThe IPv4 gateway address of the fifth ethernet interface
1.3.6.1.4.1.5597.3.4.8.4.4ScalarmbgLtCfgEthernetIf4DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.4.5ScalarmbgLtCfgEthernetIf4IPv6IP1read-writecurrentThe first IPv6 address of the fifth ethernet interface
1.3.6.1.4.1.5597.3.4.8.4.6ScalarmbgLtCfgEthernetIf4IPv6IP2read-writecurrentThe second IPv6 address of the fifth ethernet interface
1.3.6.1.4.1.5597.3.4.8.4.7ScalarmbgLtCfgEthernetIf4IPv6IP3read-writecurrentThe third IPv6 address of the fifth ethernet interface
1.3.6.1.4.1.5597.3.4.8.4.8ScalarmbgLtCfgEthernetIf4IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.4.9ScalarmbgLtCfgEthernetIf4NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.5NodembgLtCfgEthernetIf5
1.3.6.1.4.1.5597.3.4.8.5.1ScalarmbgLtCfgEthernetIf5IPv4IPread-writecurrentThe IPv4 address of the sixth ethernet interface
1.3.6.1.4.1.5597.3.4.8.5.2ScalarmbgLtCfgEthernetIf5IPv4Netmaskread-writecurrentThe IPv4 netmask of the sixth ethernet interface
1.3.6.1.4.1.5597.3.4.8.5.3ScalarmbgLtCfgEthernetIf5IPv4Gatewayread-writecurrentThe IPv4 gateway address of the sixth ethernet interface
1.3.6.1.4.1.5597.3.4.8.5.4ScalarmbgLtCfgEthernetIf5DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.5.5ScalarmbgLtCfgEthernetIf5IPv6IP1read-writecurrentThe first IPv6 address of the sixth ethernet interface
1.3.6.1.4.1.5597.3.4.8.5.6ScalarmbgLtCfgEthernetIf5IPv6IP2read-writecurrentThe second IPv6 address of the sixth ethernet interface
1.3.6.1.4.1.5597.3.4.8.5.7ScalarmbgLtCfgEthernetIf5IPv6IP3read-writecurrentThe third IPv6 address of the sixth ethernet interface
1.3.6.1.4.1.5597.3.4.8.5.8ScalarmbgLtCfgEthernetIf5IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.5.9ScalarmbgLtCfgEthernetIf5NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.6NodembgLtCfgEthernetIf6
1.3.6.1.4.1.5597.3.4.8.6.1ScalarmbgLtCfgEthernetIf6IPv4IPread-writecurrentThe IPv4 address of the seventh ethernet interface
1.3.6.1.4.1.5597.3.4.8.6.2ScalarmbgLtCfgEthernetIf6IPv4Netmaskread-writecurrentThe IPv4 netmask of the seventh ethernet interface
1.3.6.1.4.1.5597.3.4.8.6.3ScalarmbgLtCfgEthernetIf6IPv4Gatewayread-writecurrentThe IPv4 gateway address of the seventh ethernet interface
1.3.6.1.4.1.5597.3.4.8.6.4ScalarmbgLtCfgEthernetIf6DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.6.5ScalarmbgLtCfgEthernetIf6IPv6IP1read-writecurrentThe first IPv6 address of the seventh ethernet interface
1.3.6.1.4.1.5597.3.4.8.6.6ScalarmbgLtCfgEthernetIf6IPv6IP2read-writecurrentThe second IPv6 address of the seventh ethernet interface
1.3.6.1.4.1.5597.3.4.8.6.7ScalarmbgLtCfgEthernetIf6IPv6IP3read-writecurrentThe third IPv6 address of the seventh ethernet interface
1.3.6.1.4.1.5597.3.4.8.6.8ScalarmbgLtCfgEthernetIf6IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.6.9ScalarmbgLtCfgEthernetIf6NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.7NodembgLtCfgEthernetIf7
1.3.6.1.4.1.5597.3.4.8.7.1ScalarmbgLtCfgEthernetIf7IPv4IPread-writecurrentThe IPv4 address of the eighth ethernet interface
1.3.6.1.4.1.5597.3.4.8.7.2ScalarmbgLtCfgEthernetIf7IPv4Netmaskread-writecurrentThe IPv4 netmask of the eighth ethernet interface
1.3.6.1.4.1.5597.3.4.8.7.3ScalarmbgLtCfgEthernetIf7IPv4Gatewayread-writecurrentThe IPv4 gateway address of the eighth ethernet interface
1.3.6.1.4.1.5597.3.4.8.7.4ScalarmbgLtCfgEthernetIf7DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.7.5ScalarmbgLtCfgEthernetIf7IPv6IP1read-writecurrentThe first IPv6 address of the eighth ethernet interface
1.3.6.1.4.1.5597.3.4.8.7.6ScalarmbgLtCfgEthernetIf7IPv6IP2read-writecurrentThe second IPv6 address of the eighth ethernet interface
1.3.6.1.4.1.5597.3.4.8.7.7ScalarmbgLtCfgEthernetIf7IPv6IP3read-writecurrentThe third IPv6 address of the eighth ethernet interface
1.3.6.1.4.1.5597.3.4.8.7.8ScalarmbgLtCfgEthernetIf7IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.7.9ScalarmbgLtCfgEthernetIf7NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.8NodembgLtCfgEthernetIf8
1.3.6.1.4.1.5597.3.4.8.8.1ScalarmbgLtCfgEthernetIf8IPv4IPread-writecurrentThe IPv4 address of the nineth ethernet interface
1.3.6.1.4.1.5597.3.4.8.8.2ScalarmbgLtCfgEthernetIf8IPv4Netmaskread-writecurrentThe IPv4 netmask of the nineth ethernet interface
1.3.6.1.4.1.5597.3.4.8.8.3ScalarmbgLtCfgEthernetIf8IPv4Gatewayread-writecurrentThe IPv4 gateway address of the nineth ethernet interface
1.3.6.1.4.1.5597.3.4.8.8.4ScalarmbgLtCfgEthernetIf8DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.8.5ScalarmbgLtCfgEthernetIf8IPv6IP1read-writecurrentThe first IPv6 address of the nineth ethernet interface
1.3.6.1.4.1.5597.3.4.8.8.6ScalarmbgLtCfgEthernetIf8IPv6IP2read-writecurrentThe second IPv6 address of the nineth ethernet interface
1.3.6.1.4.1.5597.3.4.8.8.7ScalarmbgLtCfgEthernetIf8IPv6IP3read-writecurrentThe third IPv6 address of the nineth ethernet interface
1.3.6.1.4.1.5597.3.4.8.8.8ScalarmbgLtCfgEthernetIf8IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.8.9ScalarmbgLtCfgEthernetIf8NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.8.9NodembgLtCfgEthernetIf9
1.3.6.1.4.1.5597.3.4.8.9.1ScalarmbgLtCfgEthernetIf9IPv4IPread-writecurrentThe IPv4 address of the tenth ethernet interface
1.3.6.1.4.1.5597.3.4.8.9.2ScalarmbgLtCfgEthernetIf9IPv4Netmaskread-writecurrentThe IPv4 netmask of the tenth ethernet interface
1.3.6.1.4.1.5597.3.4.8.9.3ScalarmbgLtCfgEthernetIf9IPv4Gatewayread-writecurrentThe IPv4 gateway address of the tenth ethernet interface
1.3.6.1.4.1.5597.3.4.8.9.4ScalarmbgLtCfgEthernetIf9DHCPClientread-writecurrentIs DHCP used to get IP parameters for this interface
1.3.6.1.4.1.5597.3.4.8.9.5ScalarmbgLtCfgEthernetIf9IPv6IP1read-writecurrentThe first IPv6 address of the tenth ethernet interface
1.3.6.1.4.1.5597.3.4.8.9.6ScalarmbgLtCfgEthernetIf9IPv6IP2read-writecurrentThe second IPv6 address of the tenth ethernet interface
1.3.6.1.4.1.5597.3.4.8.9.7ScalarmbgLtCfgEthernetIf9IPv6IP3read-writecurrentThe third IPv6 address of the tenth ethernet interface
1.3.6.1.4.1.5597.3.4.8.9.8ScalarmbgLtCfgEthernetIf9IPv6Autoconfread-writecurrentIs IPv6 Autoconf used for this interface
1.3.6.1.4.1.5597.3.4.8.9.9ScalarmbgLtCfgEthernetIf9NetLinkModeread-writecurrentLink mode for this interface
1.3.6.1.4.1.5597.3.4.9NodembgLtCfgSHS
1.3.6.1.4.1.5597.3.4.9.1ScalarmbgLtCfgSHSCritLimitread-writecurrentMax. number of milliseconds the two SHS references can differ before a SHS Critical Timelimit error is issued
1.3.6.1.4.1.5597.3.4.9.2ScalarmbgLtCfgSHSWarnLimitread-writecurrentMax. number of milliseconds the two SHS references can differ before a SHS Warning Timelimit error is issued
1.3.6.1.4.1.5597.3.4.10NodembgLtCfgMRS
1.3.6.1.4.1.5597.3.4.10.1ScalarmbgLtCfgMRSRefPriorityread-writecurrentPriority of MRS Reference Sources, as a comma-separated list
1.3.6.1.4.1.5597.3.5NodembgLtCmd
1.3.6.1.4.1.5597.3.5.1ScalarmbgLtCmdExecuteread-writecurrentSend a command to the timeserver to be executed
1.3.6.1.4.1.5597.3.5.2ScalarmbgLtCmdSetRefTimeread-writecurrentSet the time of the reference clock and the LANTIME itself
1.3.6.1.4.1.5597.3.10NodembgLtPtp
1.3.6.1.4.1.5597.3.10.1ScalarmbgLtPtpModeread-onlycurrentDisplay current PTPv2 modus as string
1.3.6.1.4.1.5597.3.10.2ScalarmbgLtPtpModeValread-onlycurrentDisplay current PTPv2 modus as integer
1.3.6.1.4.1.5597.3.10.3ScalarmbgLtPtpPortStateread-onlycurrentCurrent PTPv2 port state as string
1.3.6.1.4.1.5597.3.10.4ScalarmbgLtPtpPortStateValread-onlycurrentCurrent PTPv2 port state as integer
1.3.6.1.4.1.5597.3.10.5ScalarmbgLtPtpOffsetFromGMread-onlycurrentCurrent PTPv2 offset from grandmaster as string
1.3.6.1.4.1.5597.3.10.6ScalarmbgLtPtpOffsetFromGMValread-onlycurrentCurrent PTPv2 offset from grandmaster in nanoseconds
1.3.6.1.4.1.5597.3.10.7ScalarmbgLtPtpDelayread-onlycurrentshows the current network delay in nanoseconds as string
1.3.6.1.4.1.5597.3.10.8ScalarmbgLtPtpDelayValread-onlycurrentshows the current network delay in nanoseconds
1.3.6.1.4.1.5597.3.11NodembgLtFdm
1.3.6.1.4.1.5597.3.11.1ScalarmbgLtFdmPlFreqread-onlycurrentshows the current powerline frequency in mHz as an Integer32 value
1.3.6.1.4.1.5597.3.11.2ScalarmbgLtFdmFreqDevread-onlycurrentshows the current frequency deviation in mHz as an Integer32 value
1.3.6.1.4.1.5597.3.11.3ScalarmbgLtFdmNomFreqread-onlycurrentshows the nominal frequency in mHz as an Integer32 value
1.3.6.1.4.1.5597.3.90NodembgLtConformance
1.3.6.1.4.1.5597.3.90.1NodembgLtCompliances
1.3.6.1.4.1.5597.3.90.1.1CompliancembgLtCompliancecurrentThe compliance statement for SNMP entities which implement version 2 of the LANTIME MIB
1.3.6.1.4.1.5597.3.90.2NodembgLtGroups
1.3.6.1.4.1.5597.3.90.2.1GroupmbgLtObjectsGroupcurrentThe collection of objects for the LANTIME MIB
1.3.6.1.4.1.5597.3.90.2.2GroupmbgLtTrapsGroupcurrentThe collection of traps for the LANTIME MIB