ME1200-USERS-MIB
22 objects
This is a private version of Users
Imported Objects
| CISCOME1200-MIB | me1200SwitchMgmt |
| ME1200-TC | ME1200DisplayString ME1200RowEditorState |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9.9.815.1.58 | Identityme1200UsersMIB | This is a private version of Users | ||
| 1.3.6.1.4.1.9.9.815.1.58.1 | Nodeme1200UsersMIBObjects | |||
| 1.3.6.1.4.1.9.9.815.1.58.1.2 | Nodeme1200UsersConfig | |||
| 1.3.6.1.4.1.9.9.815.1.58.1.2.1 | Tableme1200UsersConfigTable | not-accessible | current | The table is Users onfiguration table. The index is user name. |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.1.1 | Rowme1200UsersConfigEntry | not-accessible | current | Each entry has a set of parameters |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.1.1.1 | Columnme1200UsersConfigUsername | not-accessible | current | Name of user. |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.1.1.2 | Columnme1200UsersConfigPrivilege | read-write | current | Privilege level of the user. |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.1.1.3 | Columnme1200UsersConfigEncrypted | read-write | current | The flag indicates the password is encrypted or not. TRUE means the password is encrypted. FALSE means the password is plain text. |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.1.1.4 | Columnme1200UsersConfigPassword | read-write | current | Password of the user. The password length depends on the type of password. If the password is encrypted, then the length is from 4 to 44. If it is unencrypted,… |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.1.1.100 | Columnme1200UsersConfigAction | read-write | current | Action |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.2 | Nodeme1200UsersConfigTableRowEditor | |||
| 1.3.6.1.4.1.9.9.815.1.58.1.2.2.1 | Scalarme1200UsersConfigTableRowEditorUsername | read-write | current | Name of user. |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.2.2 | Scalarme1200UsersConfigTableRowEditorPrivilege | read-write | current | Privilege level of the user. |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.2.3 | Scalarme1200UsersConfigTableRowEditorEncrypted | read-write | current | The flag indicates the password is encrypted or not. TRUE means the password is encrypted. FALSE means the password is plain text. |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.2.4 | Scalarme1200UsersConfigTableRowEditorPassword | read-write | current | Password of the user. The password length depends on the type of password. If the password is encrypted, then the length is from 4 to 44. If it is unencrypted,… |
| 1.3.6.1.4.1.9.9.815.1.58.1.2.2.100 | Scalarme1200UsersConfigTableRowEditorAction | read-write | current | Action |
| 1.3.6.1.4.1.9.9.815.1.58.2 | Nodeme1200UsersMIBConformance | |||
| 1.3.6.1.4.1.9.9.815.1.58.2.1 | Nodeme1200UsersMIBCompliances | |||
| 1.3.6.1.4.1.9.9.815.1.58.2.1.1 | Complianceme1200UsersMIBCompliance | current | The compliance statement for the implementation. | |
| 1.3.6.1.4.1.9.9.815.1.58.2.2 | Nodeme1200UsersMIBGroups | |||
| 1.3.6.1.4.1.9.9.815.1.58.2.2.1 | Groupme1200UsersConfigTableInfoGroup | current | A collection of objects suitable for bulk operations. | |
| 1.3.6.1.4.1.9.9.815.1.58.2.2.2 | Groupme1200UsersConfigTableRowEditorInfoGroup | current | A collection of objects suitable for bulk operations. |