METRO1500-MIB
221 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3 | Nodeorg | |||
| 1.3.6 | Nodedod | |||
| 1.3.6.1 | Nodeinternet | |||
| 1.3.6.1.4 | Nodeprivate | |||
| 1.3.6.1.4.1 | Nodeenterprises | |||
| 1.3.6.1.4.1.2544 | Nodeadva | |||
| 1.3.6.1.4.1.2544.1 | NodeadvaProducts | |||
| 1.3.6.1.4.1.2544.1.3 | Nodemetro1500 | |||
| 1.3.6.1.4.1.2544.1.3.1 | Nodemetro1500Main | |||
| 1.3.6.1.4.1.2544.1.3.1.1 | Nodemetro1500Housing | |||
| 1.3.6.1.4.1.2544.1.3.1.1.1 | Scalarmetro1500Manufacturer | read-only | mandatory | Manufacturer of the METRO1500 System |
| 1.3.6.1.4.1.2544.1.3.1.1.2 | Scalarmetro1500MainType | read-only | mandatory | Type of the METRO1500 System |
| 1.3.6.1.4.1.2544.1.3.1.1.3 | Scalarmetro1500MainSerialNumber | read-only | mandatory | Serial Number of the METRO1500 System |
| 1.3.6.1.4.1.2544.1.3.1.1.4 | Scalarmetro1500MainHardwareVersion | read-only | mandatory | Hardware Version of the METRO1500 System |
| 1.3.6.1.4.1.2544.1.3.1.1.5 | Scalarmetro1500MainSoftwareVersion | read-only | mandatory | Software Version of the METRO1500 System (Device Master). |
| 1.3.6.1.4.1.2544.1.3.1.1.6 | Scalarmetro1500MainBusMessages | read-only | mandatory | Number of received internal Messages. This Number gives Information on the internal Activity of the METRO1500 System. This should be a large integer Number exc… |
| 1.3.6.1.4.1.2544.1.3.1.1.7 | Scalarmetro1500MainBusErrors | read-only | mandatory | Number of dropped received internal Messages. This value should be 0 or a very small Integer. |
| 1.3.6.1.4.1.2544.1.3.1.1.8 | Scalarmetro1500MainLastEvent | read-only | mandatory | Since SNMP Traps are not reliable, this Number can be polled periodically. The Value is set to a nonzero Integer when an Event occurs and cleared ten Minutes a… |
| 1.3.6.1.4.1.2544.1.3.1.1.9 | Scalarmetro1500MainMotd | read-only | mandatory | Message Of The Day is the greeting when login via telnet. It shows the actual Kernel Version and the Software Update State. With the MOTD you get Information o… |
| 1.3.6.1.4.1.2544.1.3.1.1.10 | Tablemetro1500MainTrapsinkTable | not-accessible | mandatory | Table of Trapsinks |
| 1.3.6.1.4.1.2544.1.3.1.1.10.1 | Rowmetro1500MainTrapsinkEntry | not-accessible | mandatory | Entries in the Trapsink Table |
| 1.3.6.1.4.1.2544.1.3.1.1.10.1.1 | Columnmetro1500MainTrapsinkNumber | read-only | mandatory | Number of Trapsink |
| 1.3.6.1.4.1.2544.1.3.1.1.10.1.2 | Columnmetro1500MainTrapsinkAddress | read-only | mandatory | IP Address of the Management System which should receive SNMP Traps. The Logfiles are also shown in this Table |
| 1.3.6.1.4.1.2544.1.3.1.1.10.1.3 | Columnmetro1500MainTrapsinkCommunity | read-only | mandatory | Community String which is sent with a SNMP Trap to the Management Station |
| 1.3.6.1.4.1.2544.1.3.1.1.10.1.4 | Columnmetro1500MainTrapsinkPriority | read-only | mandatory | Priority of the Trapsink (lower level gets less Traps) |
| 1.3.6.1.4.1.2544.1.3.1.1.11 | Tablemetro1500MainLogfileTable | not-accessible | mandatory | Table of Log Files |
| 1.3.6.1.4.1.2544.1.3.1.1.11.1 | Rowmetro1500MainLogfileEntry | not-accessible | mandatory | Entries in the Logfile Table |
| 1.3.6.1.4.1.2544.1.3.1.1.11.1.1 | Columnmetro1500MainLogfileNumber | read-only | mandatory | Number of Logfile |
| 1.3.6.1.4.1.2544.1.3.1.1.11.1.2 | Columnmetro1500MainLogfileName | read-only | mandatory | Name of Logfile |
| 1.3.6.1.4.1.2544.1.3.1.1.11.1.3 | Columnmetro1500MainLogfileSize | read-only | mandatory | Size of Logfile |
| 1.3.6.1.4.1.2544.1.3.1.1.11.1.4 | Columnmetro1500MainLogfilePriority | read-only | mandatory | Priority of Logfile |
| 1.3.6.1.4.1.2544.1.3.1.2 | Tablemetro1500SlotTable | not-accessible | mandatory | Table of installed METRO1500 Components. Since METRO1500 can handle many different Components, in this Section only the common Information is displayed. Compon… |
| 1.3.6.1.4.1.2544.1.3.1.2.1 | Rowmetro1500SlotEntry | not-accessible | mandatory | Installed METRO1500 Components |
| 1.3.6.1.4.1.2544.1.3.1.2.1.1 | Columnmetro1500SlotNumber | read-only | mandatory | Slot Number of installed Component. The Device Master has always Slot Number 0 and is shown in the Main section. |
| 1.3.6.1.4.1.2544.1.3.1.2.1.2 | Columnmetro1500Type | read-only | mandatory | Type of installed Component |
| 1.3.6.1.4.1.2544.1.3.1.2.1.3 | Columnmetro1500SlotTypeNumber | read-only | mandatory | Integer Number between 0 and 255 unique for a specific type of installed Component. This Number can be used for management Systems to handle automatically the … |
| 1.3.6.1.4.1.2544.1.3.1.2.1.4 | Columnmetro1500SerialNumber | read-only | mandatory | Serial Number of installed Component |
| 1.3.6.1.4.1.2544.1.3.1.2.1.5 | Columnmetro1500HardwareVersion | read-only | mandatory | Hardware Version of installed Component |
| 1.3.6.1.4.1.2544.1.3.1.2.1.6 | Columnmetro1500SoftwareVersion | read-only | mandatory | SoftwareVersion of installed Component |
| 1.3.6.1.4.1.2544.1.3.1.2.1.7 | Columnmetro1500Temperature | read-only | mandatory | Temperature of installed Component in Celsius |
| 1.3.6.1.4.1.2544.1.3.1.2.1.8 | Columnmetro1500BoardVoltage | read-only | mandatory | Voltage measured directly on the board in mV |
| 1.3.6.1.4.1.2544.1.3.1.2.1.9 | Columnmetro1500DetailInfo | read-only | mandatory | A Reference to the MIB Definition where the special Options of the Component are described with more Details |
| 1.3.6.1.4.1.2544.1.3.1.2.1.10 | Columnmetro1500EPLDVersion | read-only | mandatory | Software Version on the programmable Logic Circuit |
| 1.3.6.1.4.1.2544.1.3.1.3 | Tablemetro1500PSTable | not-accessible | mandatory | Table of installed Power Supplies |
| 1.3.6.1.4.1.2544.1.3.1.3.1 | Rowmetro1500PSEntry | not-accessible | mandatory | Installed METRO1500 Power Supplies |
| 1.3.6.1.4.1.2544.1.3.1.3.1.1 | Columnmetro1500PSNumber | read-only | mandatory | Number of installed Power Supply |
| 1.3.6.1.4.1.2544.1.3.1.3.1.2 | Columnmetro1500PSOn | read-only | mandatory | Is installed Power Supply On or Off |
| 1.3.6.1.4.1.2544.1.3.1.4 | Tablemetro1500FanTable | not-accessible | mandatory | Table of installed Fans |
| 1.3.6.1.4.1.2544.1.3.1.4.1 | Rowmetro1500FanEntry | not-accessible | mandatory | Installed METRO1500 Fans |
| 1.3.6.1.4.1.2544.1.3.1.4.1.1 | Columnmetro1500FanNumber | read-only | mandatory | Number of installed Fan |
| 1.3.6.1.4.1.2544.1.3.1.4.1.2 | Columnmetro1500FanOn | read-only | mandatory | Is installed Fan On or Off |
| 1.3.6.1.4.1.2544.1.3.5 | Nodemetro1500Converter | |||
| 1.3.6.1.4.1.2544.1.3.5.1 | Tablemetro1500ConverterTable | not-accessible | mandatory | Table of installed METRO1500 Converters |
| 1.3.6.1.4.1.2544.1.3.5.1.1 | Rowmetro1500ConverterEntry | not-accessible | mandatory | Installed METRO1500 Converters |
| 1.3.6.1.4.1.2544.1.3.5.1.1.1 | Columnmetro1500ConverterNumber | read-only | mandatory | Slot Number of installed Converter Card |
| 1.3.6.1.4.1.2544.1.3.5.1.1.2 | Columnmetro1500RxLoc | read-only | mandatory | Local Receiver has Signal (On) or Loss of Signal (Off) |
| 1.3.6.1.4.1.2544.1.3.5.1.1.3 | Columnmetro1500TxLoc | read-only | mandatory | Local Transmitter is On or Off |
| 1.3.6.1.4.1.2544.1.3.5.1.1.4 | Columnmetro1500TxLocC | read-only | mandatory | Current of the local Transmitter in mA. This Entry is only available if a Current Sensor is installed |
| 1.3.6.1.4.1.2544.1.3.5.1.1.5 | Columnmetro1500TxLocTemp | read-only | mandatory | Temperature of the local Transmitter in Celsius. This Entry is only available if the Laser is cooled |
| 1.3.6.1.4.1.2544.1.3.5.1.1.6 | Columnmetro1500RxRem | read-only | mandatory | Remote Receiver has Signal (On) or Loss of Signal (Off) |
| 1.3.6.1.4.1.2544.1.3.5.1.1.7 | Columnmetro1500TxRem | read-only | mandatory | Remote Transmitter is On or Off |
| 1.3.6.1.4.1.2544.1.3.5.1.1.8 | Columnmetro1500TxRemC | read-only | mandatory | Current of the Remote Transmitter in Milli Ampere. This Entry is only available if a Current Sensor is installed |
| 1.3.6.1.4.1.2544.1.3.5.1.1.9 | Columnmetro1500TxRemTemp | read-only | mandatory | Temperature of the Remote Transmitter in Celsius This Entry is only available if the Laser is cooled |
| 1.3.6.1.4.1.2544.1.3.5.1.1.10 | Columnmetro1500RxRem2 | read-only | mandatory | 2nd Remote receiver has Signal (On) or Loss of Signal (Off). (Only available if a 2nd Remote Receiver is installed) |
| 1.3.6.1.4.1.2544.1.3.5.1.1.11 | Columnmetro1500ClockState | read-only | mandatory | Status of the Clock. This Entry is only available if a Clock is installed. If the Clock is enabled, and has an error output, and cannot synchronize to the Sign… |
| 1.3.6.1.4.1.2544.1.3.5.1.1.12 | Columnmetro1500ClockFreq | read-only | mandatory | Frequency of the Clock in MBit/s. Only available if a Clock is installed. |
| 1.3.6.1.4.1.2544.1.3.5.1.1.13 | Columnmetro1500LocLoop | read-only | mandatory | Local Loop is set to On or to Off |
| 1.3.6.1.4.1.2544.1.3.5.1.1.14 | Columnmetro1500RemLoop | read-only | mandatory | Remote Loop is set to On or to Off |
| 1.3.6.1.4.1.2544.1.3.5.1.1.15 | Columnmetro1500ClockType | read-only | mandatory | Type of the Clock. Only available, if a Clock is installed. |
| 1.3.6.1.4.1.2544.1.3.10 | Nodemetro1500Switch | |||
| 1.3.6.1.4.1.2544.1.3.10.1 | Tablemetro1500SwitchTable | not-accessible | mandatory | Table of installed METRO1500 Switches |
| 1.3.6.1.4.1.2544.1.3.10.1.1 | Rowmetro1500SwitchEntry | not-accessible | mandatory | Installed METRO1500 Switches |
| 1.3.6.1.4.1.2544.1.3.10.1.1.1 | Columnmetro1500SwitchNumber | read-only | mandatory | Slot Number of installed Remote Optical Switch Card |
| 1.3.6.1.4.1.2544.1.3.10.1.1.2 | Columnmetro1500SwitchLine | read-only | mandatory | Active Line of Remote Optical Switch |
| 1.3.6.1.4.1.2544.1.3.10.1.1.3 | Columnmetro1500SwitchMode | read-only | mandatory | Mode of Transmit Line of Remote Optical Switch |
| 1.3.6.1.4.1.2544.1.3.10.1.1.4 | Columnmetro1500SwitchLaserOn | read-only | mandatory | Shows if the reference Laser is On or Off |
| 1.3.6.1.4.1.2544.1.3.10.1.1.5 | Columnmetro1500SwitchLineAavail | read-only | mandatory | Is Line A of Remote Optical Switch available? |
| 1.3.6.1.4.1.2544.1.3.10.1.1.6 | Columnmetro1500SwitchLineBavail | read-only | mandatory | Is Line B of Remote Optical Switch available |
| 1.3.6.1.4.1.2544.1.3.14 | Nodemetro1500EthernetHub | |||
| 1.3.6.1.4.1.2544.1.3.14.1 | Tablemetro1500EthernetHubTable | not-accessible | mandatory | Table of installed FSP-II Hub Cards |
| 1.3.6.1.4.1.2544.1.3.14.1.1 | Rowmetro1500EthernetHubEntry | not-accessible | mandatory | Installed FSP-II Hub Cards |
| 1.3.6.1.4.1.2544.1.3.14.1.1.1 | Columnmetro1500EthernetHubNumber | read-only | mandatory | Slot Number of installed Hub Card |
| 1.3.6.1.4.1.2544.1.3.14.1.1.10 | Columnmetro1500EthernetHubPortEnable1 | read-only | mandatory | is Hub Port 1 enabled ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.11 | Columnmetro1500EthernetHubPortPartitionStatus1 | read-only | mandatory | is Port 1 partitioned ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.12 | Columnmetro1500EthernetHubPortLinkStatus1 | read-only | mandatory | does Port 1 receive Link Pulses ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.13 | Columnmetro1500EthernetHubPortPolarity1 | read-only | mandatory | polarity of input signal at Port 1 |
| 1.3.6.1.4.1.2544.1.3.14.1.1.20 | Columnmetro1500EthernetHubPortEnable2 | read-only | mandatory | is Hub Port 2 enabled ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.21 | Columnmetro1500EthernetHubPortPartitionStatus2 | read-only | mandatory | is Port 2 partitioned ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.22 | Columnmetro1500EthernetHubPortLinkStatus2 | read-only | mandatory | does Port 2 receive Link Pulses ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.23 | Columnmetro1500EthernetHubPortPolarity2 | read-only | mandatory | polarity of input signal at Port 2 |
| 1.3.6.1.4.1.2544.1.3.14.1.1.30 | Columnmetro1500EthernetHubPortEnable3 | read-only | mandatory | is Hub Port 3 enabled ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.31 | Columnmetro1500EthernetHubPortPartitionStatus3 | read-only | mandatory | is Port 3 partitioned ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.32 | Columnmetro1500EthernetHubPortLinkStatus3 | read-only | mandatory | does Port 3 receive Link Pulses ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.33 | Columnmetro1500EthernetHubPortPolarity3 | read-only | mandatory | polarity of input signal at Port 3 |
| 1.3.6.1.4.1.2544.1.3.14.1.1.40 | Columnmetro1500EthernetHubPortEnable4 | read-only | mandatory | is Hub Port 4 enabled ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.41 | Columnmetro1500EthernetHubPortPartitionStatus4 | read-only | mandatory | is Port 4 partitioned ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.42 | Columnmetro1500EthernetHubPortLinkStatus4 | read-only | mandatory | does Port 4 receive Link Pulses ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.43 | Columnmetro1500EthernetHubPortPolarity4 | read-only | mandatory | polarity of input signal at Port 4 |
| 1.3.6.1.4.1.2544.1.3.14.1.1.50 | Columnmetro1500EthernetHubPortEnable5 | read-only | mandatory | is Hub Port 5 enabled ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.51 | Columnmetro1500EthernetHubPortPartitionStatus5 | read-only | mandatory | is Port 5 partitioned ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.52 | Columnmetro1500EthernetHubPortLinkStatus5 | read-only | mandatory | does Port 5 receive Link Pulses ? |
| 1.3.6.1.4.1.2544.1.3.14.1.1.53 | Columnmetro1500EthernetHubPortPolarity5 | read-only | mandatory | polarity of input signal at Port 5 |
| 1.3.6.1.4.1.2544.1.3.15 | Nodemetro1500TDM | |||
| 1.3.6.1.4.1.2544.1.3.15.1 | Tablemetro1500TDMTable | not-accessible | mandatory | Table of installed FSP-II TDM Cards |
| 1.3.6.1.4.1.2544.1.3.15.1.1 | Rowmetro1500TDMEntry | not-accessible | mandatory | Installed FSP-II TDM Cards |
| 1.3.6.1.4.1.2544.1.3.15.1.1.1 | Columnmetro1500TDMNumber | read-only | mandatory | Slot Number of installed TDM Card |
| 1.3.6.1.4.1.2544.1.3.15.1.1.4 | Columnmetro1500TDMRxRem | read-only | mandatory | Does the remote receiver receive Light (on) or not (off)? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.5 | Columnmetro1500TDMRxSync | read-only | mandatory | Is the input signal synchronized with the corresponding TDM card? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.6 | Columnmetro1500TDMTxRem | read-only | mandatory | State of the Remote Transmitter |
| 1.3.6.1.4.1.2544.1.3.15.1.1.7 | Columnmetro1500TDMTxRemC | read-only | mandatory | Current of the remote Transmitter in mA |
| 1.3.6.1.4.1.2544.1.3.15.1.1.8 | Columnmetro1500TDMTxRemTemp | read-only | mandatory | Temperature of the remote Transmitter in Celsius |
| 1.3.6.1.4.1.2544.1.3.15.1.1.9 | Columnmetro1500TDMLocLoop | read-only | mandatory | Loop for all Local Inputs enabled (on) or disabled (off) |
| 1.3.6.1.4.1.2544.1.3.15.1.1.20 | Columnmetro1500TDMLocModuleInst1 | read-only | mandatory | is local Module 1 installed ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.21 | Columnmetro1500TDMLocModuleEnable1 | read-only | mandatory | is local Module 1 enabled ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.22 | Columnmetro1500TDMLocModuleRx1 | read-only | mandatory | local receiver 1 gets signal (on) |
| 1.3.6.1.4.1.2544.1.3.15.1.1.23 | Columnmetro1500TDMLocModuleTx1 | read-only | mandatory | state of the local transmitter |
| 1.3.6.1.4.1.2544.1.3.15.1.1.24 | Columnmetro1500TDMLocModuleRemoteData1 | read-only | mandatory | receiving data for this module from the remote side |
| 1.3.6.1.4.1.2544.1.3.15.1.1.25 | Columnmetro1500TDMLocModuleClockFrequency1 | read-only | mandatory | data rate of the clock installed on local Module 1 in MBit/s |
| 1.3.6.1.4.1.2544.1.3.15.1.1.26 | Columnmetro1500TDMLocModuleClockError1 | read-only | mandatory | data rate and clock frequency are not synchronized |
| 1.3.6.1.4.1.2544.1.3.15.1.1.30 | Columnmetro1500TDMLocModuleInst2 | read-only | mandatory | is local Module 2 installed ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.31 | Columnmetro1500TDMLocModuleEnable2 | read-only | mandatory | is local Module 2 enabled ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.32 | Columnmetro1500TDMLocModuleRx2 | read-only | mandatory | local receiver 2 gets signal (on) |
| 1.3.6.1.4.1.2544.1.3.15.1.1.33 | Columnmetro1500TDMLocModuleTx2 | read-only | mandatory | state of the local transmitter |
| 1.3.6.1.4.1.2544.1.3.15.1.1.34 | Columnmetro1500TDMLocModuleRemoteData2 | read-only | mandatory | receiving data for this module from the remote side |
| 1.3.6.1.4.1.2544.1.3.15.1.1.35 | Columnmetro1500TDMLocModuleClockFrequency2 | read-only | mandatory | data rate of the clock installed on local Module 2 in MBit/s |
| 1.3.6.1.4.1.2544.1.3.15.1.1.36 | Columnmetro1500TDMLocModuleClockError2 | read-only | mandatory | data rate and clock frequency are not synchronized |
| 1.3.6.1.4.1.2544.1.3.15.1.1.40 | Columnmetro1500TDMLocModuleInst3 | read-only | mandatory | is local Module 3 installed ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.41 | Columnmetro1500TDMLocModuleEnable3 | read-only | mandatory | is local Module 3 enabled ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.42 | Columnmetro1500TDMLocModuleRx3 | read-only | mandatory | local receiver 3 gets signal (on) |
| 1.3.6.1.4.1.2544.1.3.15.1.1.43 | Columnmetro1500TDMLocModuleTx3 | read-only | mandatory | state of the local transmitter |
| 1.3.6.1.4.1.2544.1.3.15.1.1.44 | Columnmetro1500TDMLocModuleRemoteData3 | read-only | mandatory | receiving data for this module from the remote side |
| 1.3.6.1.4.1.2544.1.3.15.1.1.45 | Columnmetro1500TDMLocModuleClockFrequency3 | read-only | mandatory | data rate of the clock installed on local Module 3 in MBit/s |
| 1.3.6.1.4.1.2544.1.3.15.1.1.46 | Columnmetro1500TDMLocModuleClockError3 | read-only | mandatory | data rate and clock frequency are not synchronized |
| 1.3.6.1.4.1.2544.1.3.15.1.1.50 | Columnmetro1500TDMLocModuleInst4 | read-only | mandatory | is local Module 4 installed ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.51 | Columnmetro1500TDMLocModuleEnable4 | read-only | mandatory | is local Module 4 enabled ? |
| 1.3.6.1.4.1.2544.1.3.15.1.1.52 | Columnmetro1500TDMLocModuleRx4 | read-only | mandatory | local receiver 4 gets signal (on) |
| 1.3.6.1.4.1.2544.1.3.15.1.1.53 | Columnmetro1500TDMLocModuleTx4 | read-only | mandatory | state of the local transmitter |
| 1.3.6.1.4.1.2544.1.3.15.1.1.54 | Columnmetro1500TDMLocModuleRemoteData4 | read-only | mandatory | receiving data for this module from the remote side |
| 1.3.6.1.4.1.2544.1.3.15.1.1.55 | Columnmetro1500TDMLocModuleClockFrequency4 | read-only | mandatory | data rate of the clock installed on local Module 4 in MBit/s |
| 1.3.6.1.4.1.2544.1.3.15.1.1.56 | Columnmetro1500TDMLocModuleClockError4 | read-only | mandatory | data rate and clock frequency are not synchronized |
| 1.3.6.1.4.1.2544.1.3.100 | Nodemetro1500Trap | |||
| 1.3.6.1.4.1.2544.1.3.100.1 | Nodemetro1500HardwareAdded | Trap is sent when a new Module is inserted into the FSP-I Box | ||
| 1.3.6.1.4.1.2544.1.3.100.2 | Nodemetro1500HardwareDeleted | Trap is sent when a Module is removed from the FSP-I Box | ||
| 1.3.6.1.4.1.2544.1.3.100.3 | Nodemetro1500PSNotFail | Trap is sent when a Power Supply starts working | ||
| 1.3.6.1.4.1.2544.1.3.100.4 | Nodemetro1500PSFail | Trap is sent when a Power Supply fails | ||
| 1.3.6.1.4.1.2544.1.3.100.5 | Nodemetro1500FanNotFail | Trap is sent when a Fan starts working | ||
| 1.3.6.1.4.1.2544.1.3.100.6 | Nodemetro1500FanFail | Trap is sent when a Fan fails | ||
| 1.3.6.1.4.1.2544.1.3.100.7 | Nodemetro1500BusNotFail | Trap is sent when the internal Bus starts working again | ||
| 1.3.6.1.4.1.2544.1.3.100.8 | Nodemetro1500BusFail | Trap is sent when an internal Bus Failure occurs | ||
| 1.3.6.1.4.1.2544.1.3.100.20 | Nodemetro1500RxLocOn | Trap is sent when the local Receiver gets Signal | ||
| 1.3.6.1.4.1.2544.1.3.100.21 | Nodemetro1500RxLocOff | Trap is sent when the local Receiver has Loss of Signal | ||
| 1.3.6.1.4.1.2544.1.3.100.22 | Nodemetro1500TxLocOn | Trap is sent when the local Transmitter is switched on, Either this trap or Trap #20 should be disabled in the Configuration because they are typically sent at… | ||
| 1.3.6.1.4.1.2544.1.3.100.23 | Nodemetro1500TxLocOff | Trap is sent when the local Transmitter is switched off, Either this trap or Trap #21 should be disabled in the Configuration because they are typically sent a… | ||
| 1.3.6.1.4.1.2544.1.3.100.24 | Nodemetro1500RxRemOn | Trap is sent when the remote Receiver gets Signal | ||
| 1.3.6.1.4.1.2544.1.3.100.25 | Nodemetro1500RxRemOff | Trap is sent when the remote Receiver has Loss of Signal | ||
| 1.3.6.1.4.1.2544.1.3.100.26 | Nodemetro1500TxRemOn | Trap is sent when the remote Transmitter is switched on, Either this trap or Trap #24 should be disabled in the Configuration because they are typically sent a… | ||
| 1.3.6.1.4.1.2544.1.3.100.27 | Nodemetro1500TxRemOff | Trap is sent when the remote Transmitter is switched off, Either this trap or Trap #25 should be disabled in the Configuration because they are typically sent … | ||
| 1.3.6.1.4.1.2544.1.3.100.28 | Nodemetro1500RxRem2On | Trap is sent when the 2nd remote Receiver gets Signal. This Trap is only sent if there is a 2nd remote Receiver. | ||
| 1.3.6.1.4.1.2544.1.3.100.29 | Nodemetro1500RxRem2Off | Trap is sent when the 2nd remote Receiver has Loss of Signal. This Trap is only sent if there is a 2nd remote Receiver. | ||
| 1.3.6.1.4.1.2544.1.3.100.30 | Nodemetro1500TxRem2On | Trap is sent when the 2nd remote Transmitter is switched on, Either this Trap or Trap #28 should be disabled in the Configuration because they are typically se… | ||
| 1.3.6.1.4.1.2544.1.3.100.31 | Nodemetro1500TxRem2Off | Trap is sent when the 2nd remote Transmitter is switched off, Either this trap or Trap #29 should be disabled in the Configuration because they are typically s… | ||
| 1.3.6.1.4.1.2544.1.3.100.32 | Nodemetro1500ClockNoFail | Trap is sent if a Clock is installed and can synchronize with the input Signal. This Trap is not sent if the installed Clock does not have an error Output | ||
| 1.3.6.1.4.1.2544.1.3.100.33 | Nodemetro1500ClockFail | Trap is sent if a Clock is installed and can not synchronize with the input Signal. This trap is not sent if the installed Clock does not have an error Output | ||
| 1.3.6.1.4.1.2544.1.3.100.34 | Nodemetro1500ClockChangeFrequency | Trap is sent if a multi frequency Clock is installed and changes its frequency. | ||
| 1.3.6.1.4.1.2544.1.3.100.35 | Nodemetro1500LocLoopOn | Trap is sent if Local Loop is set to On. | ||
| 1.3.6.1.4.1.2544.1.3.100.36 | Nodemetro1500LocLoopOff | Trap is sent if Local Loop is set to Off. | ||
| 1.3.6.1.4.1.2544.1.3.100.37 | Nodemetro1500RemLoopOn | Trap is sent if Remote Loop is set to On. | ||
| 1.3.6.1.4.1.2544.1.3.100.38 | Nodemetro1500RemLoopOff | Trap is sent if Remote Loop is set to Off. | ||
| 1.3.6.1.4.1.2544.1.3.100.40 | Nodemetro1500switchReferenceLaserOn | Trap is sent when the Reference Laser is switched on | ||
| 1.3.6.1.4.1.2544.1.3.100.41 | Nodemetro1500switchReferenceLaserOff | Trap is sent when the Reference Laser is switched off | ||
| 1.3.6.1.4.1.2544.1.3.100.42 | Nodemetro1500switchToA | Trap is sent when the Switch switches to Line A | ||
| 1.3.6.1.4.1.2544.1.3.100.43 | Nodemetro1500switchToB | Trap is sent when the Switch switches to Line B | ||
| 1.3.6.1.4.1.2544.1.3.100.44 | Nodemetro1500switchAutomatic | Trap is sent when the Switch is going to Automatic State | ||
| 1.3.6.1.4.1.2544.1.3.100.45 | Nodemetro1500switchLocked | Trap is sent when the Switch is going to Locked State | ||
| 1.3.6.1.4.1.2544.1.3.100.46 | Nodemetro1500switchLineAavail | Trap is sent when the Switch Line A is available | ||
| 1.3.6.1.4.1.2544.1.3.100.47 | Nodemetro1500switchLineANotAvail | Trap is sent when the Switch Line A is not available | ||
| 1.3.6.1.4.1.2544.1.3.100.48 | Nodemetro1500switchLineBavail | Trap is sent when the Switch Line B is available | ||
| 1.3.6.1.4.1.2544.1.3.100.49 | Nodemetro1500switchLineBNotAvail | Trap is sent when the Switch Line B is not available | ||
| 1.3.6.1.4.1.2544.1.3.100.50 | Nodemetro1500repeatedMessage | Trap is sent, after three times the same trap is sent (instead of the fourth one). The original trap is suppressed for one minute. | ||
| 1.3.6.1.4.1.2544.1.3.100.51 | Nodemetro1500INNCDown | Trap is sent, when the Inter NEMI Network Connection (INNC) is down. | ||
| 1.3.6.1.4.1.2544.1.3.100.52 | Nodemetro1500INNCUp | Trap is sent, when the Inter NEMI Network Connection (INNC) is up. | ||
| 1.3.6.1.4.1.2544.1.3.100.60 | Nodemetro1500EthernetHubPortEnable | Trap is sent, when one of the ports of the Ethernet Hub is enabled by the management software (default). Use SNMP Get to get the Port Number. | ||
| 1.3.6.1.4.1.2544.1.3.100.61 | Nodemetro1500EthernetHubPortDisable | Trap is sent, when one of the ports of the Ethernet Hub is disabled by the management Software. Use SNMP Get to get the Port number. | ||
| 1.3.6.1.4.1.2544.1.3.100.62 | Nodemetro1500EthernetHubPortPartitioned | Trap is sent, when a Hub Port is disabled by the Hub Hardware. Use SNMP Get to get the Port Number. | ||
| 1.3.6.1.4.1.2544.1.3.100.63 | Nodemetro1500EthernetHubPortNotPartitioned | Trap is sent, when a Hub Port is enabled by the Hub Hardware (default). Use SNMP Get to get the Port Number. | ||
| 1.3.6.1.4.1.2544.1.3.100.64 | Nodemetro1500EthernetHubPortLinkPulses | Trap is sent, when a Hub Port starts receiving Link Pulses. Use SNMP Get to get the Port Number | ||
| 1.3.6.1.4.1.2544.1.3.100.65 | Nodemetro1500EthernetHubPortNoLinkPulses | Trap is sent, when a Hub Port stops receiving Link Pulses. Use SNMP Get to get the Port Number | ||
| 1.3.6.1.4.1.2544.1.3.100.70 | Nodemetro1500TDMRemoteSyncLoss | Trap is sent, when the synchronisation of the incoming remote data stream is lost | ||
| 1.3.6.1.4.1.2544.1.3.100.71 | Nodemetro1500TDMRemoteSync | Trap is sent, when the synchronisation of the incoming remote data stream is established | ||
| 1.3.6.1.4.1.2544.1.3.100.72 | Nodemetro1500TDMLocModuleEnabled1 | Trap is sent, when local module 1 is enabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.73 | Nodemetro1500TDMLocModuleDisable1 | Trap is sent, when local module 1 is disabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.74 | Nodemetro1500TDMLocModuleEnabled2 | Trap is sent, when local module 2 is enabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.75 | Nodemetro1500TDMLocModuleDisable2 | Trap is sent, when local module 2 is disabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.76 | Nodemetro1500TDMLocModuleEnabled3 | Trap is sent, when local module 3 is enabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.77 | Nodemetro1500TDMLocModuleDisable3 | Trap is sent, when local module 3 is disabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.78 | Nodemetro1500TDMLocModuleEnabled4 | Trap is sent, when local module 4 is enabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.79 | Nodemetro1500TDMLocModuleDisable4 | Trap is sent, when local module 4 is disabled by software | ||
| 1.3.6.1.4.1.2544.1.3.100.88 | Nodemetro1500TDMLocModuleRxOn1 | Trap is sent, when the local receiver 1 of a TDM card gets modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.89 | Nodemetro1500TDMLocModuleRxOff1 | Trap is sent, when the local receiver 1 of a TDM card doesn't get modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.90 | Nodemetro1500TDMLocModuleRxOn2 | Trap is sent, when the local receiver 2 of a TDM card gets modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.91 | Nodemetro1500TDMLocModuleRxOff2 | Trap is sent, when the local receiver 2 of a TDM card doesn't get modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.92 | Nodemetro1500TDMLocModuleRxOn3 | Trap is sent, when the local receiver 3 of a TDM card gets modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.93 | Nodemetro1500TDMLocModuleRxOff3 | Trap is sent, when the local receiver 3 of a TDM card doesn't get modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.94 | Nodemetro1500TDMLocModuleRxOn4 | Trap is sent, when the local receiver 4 of a TDM card gets modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.95 | Nodemetro1500TDMLocModuleRxOff4 | Trap is sent, when the local receiver 4 of a TDM card doesn't get modulated signal | ||
| 1.3.6.1.4.1.2544.1.3.100.104 | Nodemetro1500TDMLocModuleData1 | Trap is sent, when data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.105 | Nodemetro1500TDMLocModuleNoData1 | Trap is sent, when no data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.106 | Nodemetro1500TDMLocModuleData2 | Trap is sent, when data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.107 | Nodemetro1500TDMLocModuleNoData2 | Trap is sent, when no data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.108 | Nodemetro1500TDMLocModuleData3 | Trap is sent, when data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.109 | Nodemetro1500TDMLocModuleNoData3 | Trap is sent, when no data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.110 | Nodemetro1500TDMLocModuleData4 | Trap is sent, when data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.111 | Nodemetro1500TDMLocModuleNoData4 | Trap is sent, when no data from the remote side is available for this TDM channel | ||
| 1.3.6.1.4.1.2544.1.3.100.120 | Nodemetro1500TDMLocModuleClockFail1 | Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock | ||
| 1.3.6.1.4.1.2544.1.3.100.121 | Nodemetro1500TDMLocModuleClockNoFail1 | Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock | ||
| 1.3.6.1.4.1.2544.1.3.100.122 | Nodemetro1500TDMLocModuleClockFail2 | Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock | ||
| 1.3.6.1.4.1.2544.1.3.100.123 | Nodemetro1500TDMLocModuleClockNoFail2 | Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock | ||
| 1.3.6.1.4.1.2544.1.3.100.124 | Nodemetro1500TDMLocModuleClockFail3 | Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock | ||
| 1.3.6.1.4.1.2544.1.3.100.125 | Nodemetro1500TDMLocModuleClockNoFail3 | Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock | ||
| 1.3.6.1.4.1.2544.1.3.100.126 | Nodemetro1500TDMLocModuleClockFail4 | Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock | ||
| 1.3.6.1.4.1.2544.1.3.100.127 | Nodemetro1500TDMLocModuleClockNoFail4 | Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock |