MICROSENS-G6-NOTIFICATION-MIB
121 objects
Microsens private NOTIFICATION for Generation 6 Software Platform
Imported Objects
| RFC-1215 | TRAP-TYPE |
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString MacAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3181 | Identitymicrosens | Microsens private NOTIFICATION for Generation 6 Software Platform | ||
| 1.3.6.1.4.1.3181.10 | NodemanagedSwitches | |||
| 1.3.6.1.4.1.3181.10.6 | Nodeg6 | |||
| 1.3.6.1.4.1.3181.10.6.1 | Nodeg6TrapGroup | |||
| 1.3.6.1.4.1.3181.10.6.1.1 | Nodeg6Trap | |||
| 1.3.6.1.4.1.3181.10.6.1.1.3 | Notificationg6TrapDebug | current | Internal Debug Messages. | |
| 1.3.6.1.4.1.3181.10.6.1.1.4 | Notificationg6TrapAliveTest | current | Can be used to check out event and notification system with no effect to the system operation. | |
| 1.3.6.1.4.1.3181.10.6.1.1.5 | Notificationg6TrapFirmwareUpdateOk | current | Firmware installation has successfully taken place. | |
| 1.3.6.1.4.1.3181.10.6.1.1.6 | Notificationg6TrapFirmwareUpdateFail | current | Firmware installation has FAILED. | |
| 1.3.6.1.4.1.3181.10.6.1.1.7 | Notificationg6TrapLicenseViolation | current | Firmware is used for which no license has been granted. Please contact sales representant. | |
| 1.3.6.1.4.1.3181.10.6.1.1.8 | Notificationg6TrapColdStart | current | The device has booted. Data transmission was interrupted. | |
| 1.3.6.1.4.1.3181.10.6.1.1.9 | Notificationg6TrapWarmStart | current | The device has (partially) booted without interupting data transmission services. | |
| 1.3.6.1.4.1.3181.10.6.1.1.10 | Notificationg6TrapFactoryReset | current | Configuration factory reset is executed via local push button on the device. | |
| 1.3.6.1.4.1.3181.10.6.1.1.11 | Notificationg6TrapConfigurationLoaded | current | All or a specific configuration file(s) has been restored and activated. | |
| 1.3.6.1.4.1.3181.10.6.1.1.12 | Notificationg6TrapChangeConfig | current | A configuration parameter has been modified and activated. | |
| 1.3.6.1.4.1.3181.10.6.1.1.13 | Notificationg6TrapChangeOfflineConfig | current | An offline configuration parameter has been modified. The running system is not affected. | |
| 1.3.6.1.4.1.3181.10.6.1.1.14 | Notificationg6TrapActionResponse | current | Not a customer event. Contains the reponse string to an action command. | |
| 1.3.6.1.4.1.3181.10.6.1.1.15 | Notificationg6TrapCommitConfig | current | Not a customer event. Recent configuration changes should now be stored and activated. | |
| 1.3.6.1.4.1.3181.10.6.1.1.16 | Notificationg6TrapPowerSupplyOk | current | Power supply has been restored. Applies to units with redundant supplies only. | |
| 1.3.6.1.4.1.3181.10.6.1.1.17 | Notificationg6TrapPowerSupplyFail | current | Power supply has FAILED. Applies to units with redundant supplies only. | |
| 1.3.6.1.4.1.3181.10.6.1.1.18 | Notificationg6TrapLogin | current | An operator has logged onto the system. | |
| 1.3.6.1.4.1.3181.10.6.1.1.19 | Notificationg6TrapLogout | current | An operator has logged off from the system. | |
| 1.3.6.1.4.1.3181.10.6.1.1.20 | Notificationg6TrapLoginAttempt | current | An operator login has failed due to invalid login or password. | |
| 1.3.6.1.4.1.3181.10.6.1.1.21 | Notificationg6TrapLinkUp | current | A port has gone online and is ready to transport data. | |
| 1.3.6.1.4.1.3181.10.6.1.1.22 | Notificationg6TrapLinkDown | current | A port has gone down. Data transport on this port is no longer possible. | |
| 1.3.6.1.4.1.3181.10.6.1.1.23 | Notificationg6TrapRingNormal | current | A ring is back to normal operation. Protection is available. | |
| 1.3.6.1.4.1.3181.10.6.1.1.24 | Notificationg6TrapRingBackup | current | A ring has switched to the redundant backup path. | |
| 1.3.6.1.4.1.3181.10.6.1.1.25 | Notificationg6TrapRingFailure | current | A ring has FAILED. Normal and backup path are unavailable. | |
| 1.3.6.1.4.1.3181.10.6.1.1.26 | Notificationg6TrapCouplingState | current | Coupling controller state change. | |
| 1.3.6.1.4.1.3181.10.6.1.1.27 | Notificationg6TrapTemperatureOk | current | Operating temperature is within acceptable limits. | |
| 1.3.6.1.4.1.3181.10.6.1.1.28 | Notificationg6TrapTemperatureWarning | current | Operating temperature is low or high. Performance my be degraded. Do not run under this condition for prolonged time. | |
| 1.3.6.1.4.1.3181.10.6.1.1.29 | Notificationg6TrapTemperatureFailure | current | Operating temperature is too low or too high. The unit may switch itself off to protect itself anytime soon. | |
| 1.3.6.1.4.1.3181.10.6.1.1.30 | Notificationg6TrapMacAccepted | current | A MAC address has been authorized. | |
| 1.3.6.1.4.1.3181.10.6.1.1.31 | Notificationg6TrapMacAuthError | current | MAC authorization error. | |
| 1.3.6.1.4.1.3181.10.6.1.1.32 | Notificationg6TrapMacBlocked | current | A MAC address has been blocked. | |
| 1.3.6.1.4.1.3181.10.6.1.1.33 | Notificationg6TrapMacBlockedVlan | current | A MAC address has been blocked. Assigned to unauthorized VLAN. | |
| 1.3.6.1.4.1.3181.10.6.1.1.34 | Notificationg6TrapMacDisconnected | current | A MAC address has been disconnected. | |
| 1.3.6.1.4.1.3181.10.6.1.1.35 | Notificationg6TrapSfpInserted | current | An SFP (pluggable optical or electrical port module) has been inserted. | |
| 1.3.6.1.4.1.3181.10.6.1.1.36 | Notificationg6TrapSfpRemoved | current | An SFP (pluggable optical or electrical port module) has been removed from the device. | |
| 1.3.6.1.4.1.3181.10.6.1.1.37 | Notificationg6TrapSfpSignalPresent | current | An SFP (pluggable optical or electrical port module) has detected an optical receive signal. | |
| 1.3.6.1.4.1.3181.10.6.1.1.38 | Notificationg6TrapSfpSignalLoss | current | An SFP (pluggable optical or electrical port module) has lost its receive signal. | |
| 1.3.6.1.4.1.3181.10.6.1.1.39 | Notificationg6TrapSfpSignalChange | current | An SFP (pluggable optical or electrical port module) has detected a change in the optical input power level. | |
| 1.3.6.1.4.1.3181.10.6.1.1.40 | Notificationg6TrapSfpMismatch | current | An SFP (pluggable optical or electrical port module) has been inserted which does not match the required feature(s). | |
| 1.3.6.1.4.1.3181.10.6.1.1.41 | Notificationg6TrapPoeConnect | current | A POE (Power over Ethernet) device is connected an powered. | |
| 1.3.6.1.4.1.3181.10.6.1.1.42 | Notificationg6TrapPoeVoltage | current | The POE (Power over Ethernet) operating voltage is too low. | |
| 1.3.6.1.4.1.3181.10.6.1.1.43 | Notificationg6TrapPoeError | current | A POE (Power over Ethernet) error has occurred. | |
| 1.3.6.1.4.1.3181.10.6.1.1.44 | Notificationg6TrapPoeClassmismatch | current | A POE (Power over Ethernet) powered device requires a power level not enabled or available at this port. | |
| 1.3.6.1.4.1.3181.10.6.1.1.45 | Notificationg6TrapPoeDisconnect | current | A POE (Power over Ethernet) device has been disconnected. | |
| 1.3.6.1.4.1.3181.10.6.1.1.46 | Notificationg6TrapNtpFail | current | The NTP client (Network Time Protocol) has a failure condition. | |
| 1.3.6.1.4.1.3181.10.6.1.1.47 | Notificationg6TrapHardwareError | current | A hardware error has been detected. | |
| 1.3.6.1.4.1.3181.10.6.1.1.48 | Notificationg6TrapSoftwareError | current | A software error has occured. | |
| 1.3.6.1.4.1.3181.10.6.1.1.49 | Notificationg6TrapButtonPressed | current | System button pressed. | |
| 1.3.6.1.4.1.3181.10.6.1.1.67 | Notificationg6TrapInputSignalNormal | current | An external input signal has been deactivated and returned to normal state. | |
| 1.3.6.1.4.1.3181.10.6.1.1.68 | Notificationg6TrapInputSignalActivated | current | An external input signal has been activated. | |
| 1.3.6.1.4.1.3181.10.6.1.1.69 | Notificationg6TrapOutputRelayNormal | current | A relay output signal has been deactivated and returned to normal state. | |
| 1.3.6.1.4.1.3181.10.6.1.1.70 | Notificationg6TrapOutputRelayActivated | current | An external input signal has been deactivated and returned to normal state. | |
| 1.3.6.1.4.1.3181.10.6.1.1.71 | Notificationg6TrapPacketIntercepted | current | Special filter has intercepted a data packet. | |
| 1.3.6.1.4.1.3181.10.6.1.1.72 | Notificationg6TrapScriptUnitPositive | current | A positive unit related user defined event created by script or app. | |
| 1.3.6.1.4.1.3181.10.6.1.1.73 | Notificationg6TrapScriptUnitNegative | current | A negative unit related user defined event created by script or app. | |
| 1.3.6.1.4.1.3181.10.6.1.1.74 | Notificationg6TrapScriptPortPositive | current | A positive port related user defined event created by script or app. | |
| 1.3.6.1.4.1.3181.10.6.1.1.75 | Notificationg6TrapScriptPortNegative | current | A negative port related user defined event created by script or app. | |
| 1.3.6.1.4.1.3181.10.6.1.1.76 | Notificationg6TrapScriptExecuted | current | A user defined script execution started. | |
| 1.3.6.1.4.1.3181.10.6.1.1.77 | Notificationg6TrapScriptError | current | Script execution error of a user defined script. | |
| 1.3.6.1.4.1.3181.10.6.1.1.78 | Notificationg6TrapLoopRemoved | current | Cable loop removed. Port unblocked. | |
| 1.3.6.1.4.1.3181.10.6.1.1.79 | Notificationg6TrapLoopDetected | current | Cable loop detected. Port blocked. | |
| 1.3.6.1.4.1.3181.10.6.1.1.80 | Notificationg6TrapLacpConnect | current | Aggregated link established. | |
| 1.3.6.1.4.1.3181.10.6.1.1.81 | Notificationg6TrapLacpDisconnect | current | Aggregated link down. | |
| 1.3.6.1.4.1.3181.10.6.1.1.82 | Notificationg6TrapAppInstalled | current | App installed ok. | |
| 1.3.6.1.4.1.3181.10.6.1.1.83 | Notificationg6TrapAppInstallationFail | current | App installation has failed. | |
| 1.3.6.1.4.1.3181.10.6.1.1.84 | Notificationg6TrapAppDeinstalled | current | App deinstalled. | |
| 1.3.6.1.4.1.3181.10.6.1.1.85 | Notificationg6TrapCableChangeDetected | current | Change in cable termination detected. | |
| 1.3.6.1.4.1.3181.10.6.1.1.86 | Notificationg6TrapImplausibleConfig | current | Implausible configuration detected | |
| 1.3.6.1.4.1.3181.10.6.1.1.87 | Notificationg6TrapNetworkAttack | current | Potential network attack detected | |
| 1.3.6.1.4.1.3181.10.6.1.1.88 | Notificationg6TrapModuleInserted | current | A hardware module has been inserted into the system. | |
| 1.3.6.1.4.1.3181.10.6.1.1.89 | Notificationg6TrapModuleRemoved | current | A hardware module has been removed from the system. | |
| 1.3.6.1.4.1.3181.10.6.1.1.90 | Notificationg6TrapMsp1000UnitPositive | current | A positive MSP1000 unit related event has occured. | |
| 1.3.6.1.4.1.3181.10.6.1.1.91 | Notificationg6TrapMsp1000UnitNegative | current | A negative MSP1000 unit related event has occured. | |
| 1.3.6.1.4.1.3181.10.6.1.1.92 | Notificationg6TrapMsp1000PortPositive | current | A positive MSP1000 port related event has occured. | |
| 1.3.6.1.4.1.3181.10.6.1.1.93 | Notificationg6TrapMsp1000PortNegative | current | A negative MSP1000 port related event has occured. | |
| 1.3.6.1.4.1.3181.10.6.1.1.94 | Notificationg6TrapBackupTerminated | current | Backup path not required. | |
| 1.3.6.1.4.1.3181.10.6.1.1.95 | Notificationg6TrapBackupEngaged | current | Backup path has been engaged. | |
| 1.3.6.1.4.1.3181.10.6.1.1.96 | Notificationg6TrapBackupFailure | current | Backup path could not be completed. | |
| 1.3.6.1.4.1.3181.10.6.1.1.97 | Notificationg6TrapFanOk | current | Cooling fan operating normally. | |
| 1.3.6.1.4.1.3181.10.6.1.1.98 | Notificationg6TrapFanDegraded | current | Cooling fan degraded. Replace fan soon. | |
| 1.3.6.1.4.1.3181.10.6.1.1.99 | Notificationg6TrapFanFailure | current | Cooling fan failed. Replace fan immediately | |
| 1.3.6.1.4.1.3181.10.6.1.1.100 | Notificationg6TrapIncomingAlert | current | Externally received HTTP_GET_REQUEST or received SNMP TRAP. | |
| 1.3.6.1.4.1.3181.10.6.1.1.101 | Notificationg6TrapCableTerminationEstablished | current | Cable termination established. Possible reason: A terminated remote device was connected to the cable. | |
| 1.3.6.1.4.1.3181.10.6.1.1.102 | Notificationg6TrapCableTerminationLost | current | Cable termination lost. Possible reason: A terminated remote device was disconnected from the cable or the cable was locally unplugged. | |
| 1.3.6.1.4.1.3181.10.6.1.1.103 | Notificationg6TrapTerminalServerConnected | current | Terminal server connected foreign host to local serial port. | |
| 1.3.6.1.4.1.3181.10.6.1.1.104 | Notificationg6TrapTerminalServerDisconnected | current | Terminal server disconnected foreign host from local serial port. | |
| 1.3.6.1.4.1.3181.10.6.1.1.105 | Notificationg6TrapTerminalServerFail | current | Terminal server failed in connecting foreign host to local serial port. | |
| 1.3.6.1.4.1.3181.10.6.1.1.108 | Notificationg6TrapSensorGroupChange | current | Sensor group values have changed. | |
| 1.3.6.1.4.1.3181.10.6.1.1.110 | Notificationg6TrapActorGroupChangeRequest | current | Actor group is requested to change to a new value. | |
| 1.3.6.1.4.1.3181.10.6.1.1.111 | Notificationg6TrapRegisterSmartDevice | current | A new smart device is registered. | |
| 1.3.6.1.4.1.3181.10.6.1.1.112 | Notificationg6TrapUpdateSmartDevice | current | A smart device has changed its status. | |
| 1.3.6.1.4.1.3181.10.6.1.1.115 | Notificationg6TrapRegisterSmartAttribute | current | A new smart attribute is registered. | |
| 1.3.6.1.4.1.3181.10.6.1.1.117 | Notificationg6TrapUnregisterSmartDevice | current | A smart device is unregistered. | |
| 1.3.6.1.4.1.3181.10.6.1.1.118 | Notificationg6TrapUnregisterSmartAttribute | current | A smart attribute is unregistered. | |
| 1.3.6.1.4.1.3181.10.6.1.1.119 | Notificationg6TrapSingleActorChange | current | An individual actor is set to a new value. | |
| 1.3.6.1.4.1.3181.10.6.1.1.120 | Notificationg6TrapActorGroupChanged | current | An actor group has changed to a new value. | |
| 1.3.6.1.4.1.3181.10.6.1.1.121 | Notificationg6TrapSmartOfficeInitializing | current | Smart Office is being initialized. | |
| 1.3.6.1.4.1.3181.10.6.1.1.122 | Notificationg6TrapSmartOfficeStarted | current | Smart Office is started and ready. | |
| 1.3.6.1.4.1.3181.10.6.1.1.123 | Notificationg6TrapSmartOfficeStopped | current | Smart Office is being stopped. | |
| 1.3.6.1.4.1.3181.10.6.1.1.124 | Notificationg6TrapSmartOfficeError | current | A Smart Office error has occured. | |
| 1.3.6.1.4.1.3181.10.6.1.1.125 | Notificationg6TrapOtdrMeasurements | current | An OTDR measurement has taken place and detected a change in the optical characteristics of the cable. | |
| 1.3.6.1.4.1.3181.10.6.1.2 | Nodeg6TrapObjects | |||
| 1.3.6.1.4.1.3181.10.6.1.2.1 | Scalarg6TrapObjEventName | read-only | current | Event name as text string. |
| 1.3.6.1.4.1.3181.10.6.1.2.2 | Scalarg6TrapObjGroupName | read-only | current | Event group as text string. |
| 1.3.6.1.4.1.3181.10.6.1.2.3 | Scalarg6TrapObjRelevance | read-only | current | pos neg info |
| 1.3.6.1.4.1.3181.10.6.1.2.4 | Scalarg6TrapObjSeverity | read-only | current | Severity level of this event. |
| 1.3.6.1.4.1.3181.10.6.1.2.5 | Scalarg6TrapObjSource | read-only | current | Unit or port related event. |
| 1.3.6.1.4.1.3181.10.6.1.2.6 | Scalarg6TrapObjSysName | read-only | current | User defined system name of the device originating this event. |
| 1.3.6.1.4.1.3181.10.6.1.2.7 | Scalarg6TrapObjPortId | read-only | current | Port identification in snmp compliant integer format. Value is calculated as (slot * 100) + port. |
| 1.3.6.1.4.1.3181.10.6.1.2.8 | Scalarg6TrapObjPortString | read-only | current | Port identification in slot/port notation. |
| 1.3.6.1.4.1.3181.10.6.1.2.9 | Scalarg6TrapObjPortAlias | read-only | current | Port identification using a possible user assigned alias or nickname. |
| 1.3.6.1.4.1.3181.10.6.1.2.10 | Scalarg6TrapObjDescription | read-only | current | Detailed human readable full description of the event. |
| 1.3.6.1.4.1.3181.10.6.1.2.11 | Scalarg6TrapObjMac | read-only | current | MAC address related with authentication trap. |
| 1.3.6.1.4.1.3181.10.6.1.2.12 | Scalarg6TrapObjVlanId | read-only | current | Associated VLAN id. |
| 1.3.6.1.4.1.3181.10.6.1.2.13 | Scalarg6TrapObjOfficeGroupName | read-only | current | SmartOffice actor or sensor group name. |
| 1.3.6.1.4.1.3181.10.6.1.2.14 | Scalarg6TrapObjAvgValue | read-only | current | SmartOffice group data value. Contains the average value of all elements in the same group |
| 1.3.6.1.4.1.3181.10.6.1.2.15 | Scalarg6TrapObjTotalValue | read-only | current | SmartOffice group data value. Contains the total value of all elements in the same group |