MOXA-NP6000-MIB
357 objects
The MIB module for Moxa NPort 6000 series specific information.
Imported Objects
| SNMPv2-SMI | enterprises IpAddress OBJECT-TYPE |
| SNMPv2-TC | DateAndTime DisplayString MacAddress TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.8691 | Nodemoxa | |||
| 1.3.6.1.4.1.8691.2 | Nodenport | |||
| 1.3.6.1.4.1.8691.2.8 | Identitynp6000 | The MIB module for Moxa NPort 6000 series specific information. | ||
| 1.3.6.1.4.1.8691.2.8.1 | NodeswMgmt | |||
| 1.3.6.1.4.1.8691.2.8.1.1 | Nodeoverview | |||
| 1.3.6.1.4.1.8691.2.8.1.1.1 | ScalarmodelName | read-only | current | The model name of the NPort. The possible values of this parameter are: 'NP6150' for NPort 6150, 'NP6250' for NPort 6250, 'NP6250-S-SC' for NPort 6250-S-SC, 'N… |
| 1.3.6.1.4.1.8691.2.8.1.1.2 | ScalarserialNumber | read-only | current | The serial number of the NPort. Every NPort 6000 series device server is assigned a unique serial number before it is shipped. |
| 1.3.6.1.4.1.8691.2.8.1.1.3 | ScalarfirmwareVersion | read-only | current | The version of the firmware currently running on the NPort. |
| 1.3.6.1.4.1.8691.2.8.1.1.4 | ScalarmacAddress | read-only | current | The MAC address of the NPort's Ethernet interface. |
| 1.3.6.1.4.1.8691.2.8.1.1.5 | ScalarviewLanSpeed | read-only | current | The current speed and link status of the NPort's built-in LAN port. The possible values are 'No link', '10M/Link,' or '100M/Link.' |
| 1.3.6.1.4.1.8691.2.8.1.1.6 | ScalarviewLanModuleSpeed | read-only | current | The current speed and link status of the the network module's LAN ports, if the module is installed. The value includes two parts. Each part indicates the stat… |
| 1.3.6.1.4.1.8691.2.8.1.1.7 | ScalarupTime | read-only | current | The time (in human-readable notation) since the system was was last re-initialized. |
| 1.3.6.1.4.1.8691.2.8.1.1.8 | ScalarmoduleType | read-only | current | The module name currently plugged into the NPort. |
| 1.3.6.1.4.1.8691.2.8.1.2 | NodebasicSetting | |||
| 1.3.6.1.4.1.8691.2.8.1.2.1 | NodeserverSetting | |||
| 1.3.6.1.4.1.8691.2.8.1.2.1.1 | ScalarserverName | read-write | current | A text string used to identify the NPort. |
| 1.3.6.1.4.1.8691.2.8.1.2.1.2 | ScalarserverLocation | read-write | current | A text string used to identify the location of the NPort. This option is useful for specifying the location or application of different NPort device servers. |
| 1.3.6.1.4.1.8691.2.8.1.2.2 | NodetimeSetting | |||
| 1.3.6.1.4.1.8691.2.8.1.2.2.1 | ScalartimeZone | read-write | current | The time-zone index of the NPort. |
| 1.3.6.1.4.1.8691.2.8.1.2.2.2 | ScalarlocalTime | read-write | current | The system time in seconds since 1970/1/1. |
| 1.3.6.1.4.1.8691.2.8.1.2.2.3 | ScalartimeServer | read-write | current | The NPort 6000 series device server uses SNTP (RFC-1769) for auto time calibration. Input the correct 'Time server' IP address or domain name. Once the NPort 6… |
| 1.3.6.1.4.1.8691.2.8.1.3 | NodenetworkSetting | |||
| 1.3.6.1.4.1.8691.2.8.1.3.1 | ScalaripConfiguration | read-write | current | The IP configuration mode of the NPort. You can choose from four possible IP configuration modes: Static, DHCP, DHCP/BOOTP, BOOTP, and PPPoE. |
| 1.3.6.1.4.1.8691.2.8.1.3.2 | ScalarsysIpAddress | read-write | current | An IP address is a number assigned to a network device (such as a computer) as a permanent address on the network. Computers use the IP address to identify and… |
| 1.3.6.1.4.1.8691.2.8.1.3.3 | ScalarnetMask | read-write | current | A subnet mask represents all of the network hosts at one geographic location, in one building, or on the same local area network. When a packet is sent out ove… |
| 1.3.6.1.4.1.8691.2.8.1.3.4 | ScalardefaultGateway | read-only | current | A gateway is a network computer that acts as an entrance to another network. Usually, the computers that control traffic within the network or at the local Int… |
| 1.3.6.1.4.1.8691.2.8.1.3.5 | ScalardnsServer1IpAddr | read-write | current | The first DNS server address. When the user wants to visit a particular website, the computer asks a Domain Name System (DNS) server for the website��s cor… |
| 1.3.6.1.4.1.8691.2.8.1.3.6 | ScalardnsServer2IpAddr | read-write | current | The second DNS server address. When the user wants to visit a particular website, the computer asks a Domain Name System (DNS) server for the website��s co… |
| 1.3.6.1.4.1.8691.2.8.1.3.7 | ScalarpppoeUserAccount | read-write | current | The user account used by the NPort to access the Internet using PPPoE. For dynamic broad band networks such as xDSL or Cable Modem, users must enter the userna… |
| 1.3.6.1.4.1.8691.2.8.1.3.8 | ScalarpppoePassword | read-write | current | The password used by the NPort to access the Internet using PPPoE. For dynamic broad band networks such as xDSL or Cable Modem, users must enter the username a… |
| 1.3.6.1.4.1.8691.2.8.1.3.9 | ScalarwinsFunction | read-write | current | Enable or disable the WINS server. |
| 1.3.6.1.4.1.8691.2.8.1.3.10 | ScalarwinsServer | read-write | current | If a WINS Server is connected to the network, use this field to record the WINS Server��s IP address. TCP/IP uses IP addresses to identify hosts, but users… |
| 1.3.6.1.4.1.8691.2.8.1.3.11 | Scalarlan1Speed | read-write | current | IEEE802.3 Ethernet supports the auto negotiation speed function to get suitable speeds. However, for connecting to some switches/hubs, the communication speed … |
| 1.3.6.1.4.1.8691.2.8.1.3.12 | ScalarroutingProtocol | read-write | current | The routing protocol used by the NPort. This value could be none, RIP-1, or RIP-2. |
| 1.3.6.1.4.1.8691.2.8.1.3.13 | ScalargratuitousArp | read-write | current | Enable or disable the gratuitous ARP function. For some applications, users need the NPort 6000 series device server to send broadcast packets to update the AR… |
| 1.3.6.1.4.1.8691.2.8.1.3.14 | ScalargratuitousArpSendPeriod | read-write | current | The send period of the gratuitous ARP function. |
| 1.3.6.1.4.1.8691.2.8.1.4 | NodeportSetting | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1 | NodeopModeSetting | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.1 | NodeopMode | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.1.1 | TableopModePortTable | not-accessible | current | The serial ports' operation mode table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.1.1.1 | RowopModePortEntry | not-accessible | current | The serial port's operation mode entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.1.1.1.1 | ColumnportIndex | read-only | current | The serial port index. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.1.1.1.2 | ColumnportApplication | read-write | current | The application of the serial port. Note that changing this setting may also change the operation mode. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.1.1.1.3 | ColumnportMode | read-write | current | The operation mode of the serial port. Note that changing this setting may also change the application. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2 | Nodeapplication | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1 | NodedeviceControl | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1 | TabledeviceControlTable | not-accessible | current | The Device Control application table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1 | RowdeviceControlEntry | not-accessible | current | The Device Control application entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.1 | ColumndeviceControlTcpAliveCheck | read-write | current | The TCP alive check time. 0 min: TCP connection will not be closed when the TCP connection is idle. 1 to 99 min: The NPort 6000 series device server automatica… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.2 | ColumndeviceControlMaxConnection | read-write | current | Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specif… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.3 | ColumndeviceControlIgnoreJammedIp | read-write | current | Previously, when Max connection was set to a value greater than 1, and the serial device was transmitting data, if any one of the connected hosts stopped respo… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.4 | ColumndeviceControlAllowDriverControl | read-write | current | If Max connection is greater than 1, NPort will ignore driver control commands from all connected hosts. However, if you set Allow driver control to YES, contr… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.5 | ColumndeviceControlSecure | read-write | current | If 'Secure' is enabled, the data on the Ethernet will be encrypted with SSL. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.6 | ColumndeviceControlTcpPort | read-write | current | The 'TCP port' is the TCP port that the NPort 6000 series device server uses to listen to connections, and that other devices must use to contact the NPort 600… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.7 | ColumndeviceControlConnectionDownRTS | read-write | current | For some applications, serial devices must obtain the Ethernet link status by reading the RTS signal from the NPort 6000 series device server. If this setting … |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.1.1.1.8 | ColumndeviceControlConnectionDownDTR | read-write | current | For some applications, serial devices must obtain the Ethernet link status by reading the DTR signal from the NPort 6000 series device server. If this setting … |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2 | Nodesocket | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1 | TablesocketTable | not-accessible | current | The Socket application table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1 | RowsocketEntry | not-accessible | current | The Socket application entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.1 | ColumnsocketTcpAliveCheck | read-write | current | The TCP alive check time. 0 min: TCP connection will not be closed when the TCP connection is idle. 1 to 99 min: The NPort 6000 series device server automatica… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.2 | ColumnsocketInactivityTime | read-write | current | 0 ms: TCP connection is not closed when the serial line is idle. 1-65535 ms: The NPort 6000 series device server automatically closes the TCP connection if the… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.3 | ColumnsocketMaxConnection | read-write | current | Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specif… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.4 | ColumnsocketIgnoreJammedIp | read-write | current | Previously, when Max connection was set to a value greater than 1, and the serial device was transmitting data, if any one of the connected hosts stopped respo… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.5 | ColumnsocketAllowDriverControl | read-write | current | If Max connection is greater than 1, NPort will ignore driver control commands from all connected hosts. However, if you set Allow driver control to YES, contr… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.6 | ColumnsocketSecure | read-write | current | If Secure is enabled, data sent over the Ethernet will be encrypted with SSL. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.7 | ColumnsocketTcpPort | read-write | current | The 'TCP port' is the TCP port that the NPort 6000 series device server uses to listen to connections, and that other devices must use to contact the NPort 600… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.8 | ColumnsocketCmdPort | read-write | current | The 'Command port' is a TCP port used to listen for IP-Serial Lib commands from the host. In order to prevent a TCP port conflict with other applications, the … |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.9 | ColumnsocketTcpServerConnectionDownRTS | read-write | current | For some applications, serial devices must obtain the Ethernet link status from the RTS signal sent by the NPort 6000 series device server. If this setting is … |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.10 | ColumnsocketTcpServerConnectionDownDTR | read-write | current | For some applications, serial devices must obtain the Ethernet link status from the DTR signal sent by the NPort 6000 series device server. If this setting is … |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.11 | ColumnsocketTcpClientDestinationAddress1 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this IP address. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.12 | ColumnsocketTcpClientDestinationPort1 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this TCP port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.13 | ColumnsocketTcpClientDestinationAddress2 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this IP address. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.14 | ColumnsocketTcpClientDestinationPort2 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this TCP port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.15 | ColumnsocketTcpClientDestinationAddress3 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this IP address. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.16 | ColumnsocketTcpClientDestinationPort3 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.17 | ColumnsocketTcpClientDestinationAddress4 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this IP address. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.18 | ColumnsocketTcpClientDestinationPort4 | read-write | current | The NPort 6000 series device server can connect actively to a remote host that has this port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.19 | ColumnsocketTcpClientDesignatedLocalPort1 | read-write | current | The local TCP port used to connect actively to the remote host. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.20 | ColumnsocketTcpClientDesignatedLocalPort2 | read-write | current | The local TCP port used to connect actively to the remote host. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.21 | ColumnsocketTcpClientDesignatedLocalPort3 | read-write | current | The local TCP port used to connect actively to the remote host. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.22 | ColumnsocketTcpClientDesignatedLocalPort4 | read-write | current | The local TCP port used to connect actively to the remote host. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.23 | ColumnsocketTcpClientConnectionControl | read-write | current | Events that cause the TCP client to drop the connection. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.24 | ColumnsocketUdpDestinationAddress1Begin | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and socketUdpDesti… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.25 | ColumnsocketUdpDestinationAddress1End | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between socketUdpDestinationAddress1Begin… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.26 | ColumnsocketUdpDestinationPort1 | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts that have this port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.27 | ColumnsocketUdpDestinationAddress2Begin | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and socketUdpDesti… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.28 | ColumnsocketUdpDestinationAddress2End | read-write | current | The NPort 6000 series device server can actively send UDP packets to the remote hosts whose IP addresses are in the range between socketUdpDestinationAddress2B… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.29 | ColumnsocketUdpDestinationPort2 | read-write | current | The NPort 6000 series device server can actively send UDP packets to the remote hosts that have this TCP port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.30 | ColumnsocketUdpDestinationAddress3Begin | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and socketUdpDesti… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.31 | ColumnsocketUdpDestinationAddress3End | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between socketUdpDestinationAddress3Begin… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.32 | ColumnsocketUdpDestinationPort3 | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts that have this TCP port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.33 | ColumnsocketUdpDestinationAddress4Begin | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and socketUdpDesti… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.34 | ColumnsocketUdpDestinationAddress4End | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between socketUdpDestinationAddress4Begin… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.35 | ColumnsocketUdpDestinationPort4 | read-write | current | The NPort 6000 series device server can actively send UDP packets to remote hosts that have this TCP port number. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.36 | ColumnsocketUdpLocalListenPort | read-write | current | The UDP port that the NPort 6000 series device server listens to and that other devices must use to contact the NPort 6000 series device server. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3 | NodepairConnection | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3.1 | TablepairConnectionTable | not-accessible | current | The Pair Connection table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3.1.1 | RowpairConnectionEntry | not-accessible | current | The Pair Connection entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3.1.1.1 | ColumnpairConnectionTcpAliveCheck | read-write | current | The TCP alive check time. 0 min: TCP connection will not be closed if the TCP connection becomes idle. 1 to 99 min: The NPort 6000 series device server automat… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3.1.1.2 | ColumnpairConnectionSecure | read-write | current | If Secure is enabled, the Ethernet data will be encrypted using SSL. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3.1.1.3 | ColumnpairConnectionDestinationAddress | read-write | current | The Pair Connection 'Master' will contact the network host that has the specified IP address. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3.1.1.4 | ColumnpairConnectionDestinationPort | read-write | current | Data will be transmitted through the specified port number. Note that you must configure the same TCP port number for the device server acting as the Pair Conn… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.3.1.1.5 | ColumnpairConnectionTcpPort | read-write | current | This port number must be the same port number that was set up for the Pair Connection 'Master' device server. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.4 | NodeethernetModem | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.4.1 | TableethernetModemTable | not-accessible | current | The Ethernet Modem table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.4.1.1 | RowethernetModemEntry | not-accessible | current | The Ethernet Modem entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.4.1.1.1 | ColumnethernetModemTcpAliveCheck | read-write | current | The TCP alive check time. 0 min: TCP connection will not be closed if the TCP connection becomes idle. 1 to 99 min: The NPort 6000 series device server automat… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.4.1.1.2 | ColumnethernetModemTcpPort | read-write | current | The local TCP port used to listen for incoming calls from a remote ethernet modem. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5 | Nodeterminal | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1 | TableterminalTable | not-accessible | current | The Terminal Application table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1 | RowterminalEntry | not-accessible | current | The Terminal Application entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.1 | ColumnterminalTcpAliveCheck | read-write | current | The TCP alive check time. 0 min: TCP connection will not be closed if the TCP connection becomes idle. 1 to 99 min: The NPort 6000 series device server automat… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.2 | ColumnterminalInactivityTime | read-write | current | 0 min: TCP connection will not be closed if the serial line becomes idle. 0-99 min: The NPort 6000 series device server automatically closes the TCP connection… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.3 | ColumnterminalAutoLinkProtocol | read-write | current | If Auto-Link protocol is set to 'None,' the NPort 6000 series device server will not connect to the host automatically. If Auto-Link protocol is set to 'Telnet… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.4 | ColumnterminalPrimaryHostAddress | read-write | current | If specified, designates a 'permanent' host to which the terminal will always be connected. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.5 | ColumnterminalSecondHostAddress | read-write | current | If specified, designates a 'permanent' host to which the terminal will always be connected. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.6 | ColumnterminalTelnetTcpPort | read-write | current | By default, the Telnet TCP port number is set to 23, which is the default TCP port number for Telnet. If you need to telnet to this NPort 6000 series device se… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.7 | ColumnterminalSshTcpPort | read-write | current | By default, the SSH TCP port number is set to 22, which is the default TCP port number for SSH. If you need to use SSH to connect to this NPort 6000 series dev… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.8 | ColumnterminalType | read-write | current | Defines the terminal type for outgoing connections. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.9 | ColumnterminalMaxSessions | read-write | current | Configure the max. number of sessions. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.10 | ColumnterminalChangeSession | read-write | current | Defines the control character used to change the terminal session. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.11 | ColumnterminalQuit | read-write | current | Defines the control character used to quit a terminal session. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.12 | ColumnterminalBreak | read-write | current | Defines the control character used to send a Telnet BREAK message. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.13 | ColumnterminalInterrupt | read-write | current | Defines the control character used to send a Telnet INTERRUPT message. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.14 | ColumnterminalAuthenticationType | read-write | current | The terminal authentication type. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.15 | ColumnterminalAutoLoginPrompt | read-write | current | The prompt string for the automatic login ID. When the NPort 6000 series device server receives this string from a remote telnet/rlogin server, it will automat… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.16 | ColumnterminalPasswordPrompt | read-write | current | The prompt string for the automatic login password. When the NPort 6000 series device server receives this string from a remote telnet/rlogin server, it will a… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.17 | ColumnterminalLoginUserName | read-write | current | Terminal login ID for automatic login. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.5.1.1.18 | ColumnterminalLoginPassword | read-write | current | Terminal login password for automatic login. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6 | NodereverseTerminal | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6.1 | TablereverseTerminalTable | not-accessible | current | The Reverse Terminal Application table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6.1.1 | RowreverseTerminalEntry | not-accessible | current | The Reverse Terminal Application entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6.1.1.1 | ColumnreverseTerminalTcpAliveCheck | read-write | current | The TCP alive check time. 0 min: TCP connection will not be closed when the TCP connection becomes idle. 1 to 99 min: The NPort 6000 series device server autom… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6.1.1.2 | ColumnreverseTerminalInactivityTime | read-write | current | 0 min: TCP connection will not be closed if the serial line becomes idle. 0-99 min: The NPort 6000 series device server automatically closes the TCP connection… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6.1.1.3 | ColumnreverseTerminalTcpPort | read-write | current | Each of the NPort 6000 series device server's serial ports are mapped to a TCP port. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6.1.1.4 | ColumnreverseTerminalAuthenticationType | read-write | current | The reverse terminal authentication type. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.6.1.1.5 | ColumnreverseTerminalMapKeys | read-write | current | If data received through NPort 6000 series device server's Ethernet port is sent using the 'enter' command, the data will be transmitted out through the serial… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7 | Nodeprinter | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1 | TableprinterTable | not-accessible | current | The Printer Application table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1.1 | RowprinterEntry | not-accessible | current | The Printer Application entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1.1.1 | ColumnprinterTcpAliveCheck | read-write | current | The TCP alive check time. 0 min: TCP connection will not be closed if the TCP connection becomes idle. 1 to 99 min: The NPort 6000 series device server automat… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1.1.2 | ColumnprinterTcpPort | read-only | current | The host uses this value to determine the Group to which the printer attached to this serial port belongs. These values are fixed, and cannot be changed by the… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1.1.3 | ColumnprinterGroup | read-write | current | Groups printers attached to different ports. Printers in the same group will share the printing load for printing requests to that group of printers. E.g., set… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1.1.4 | ColumnprinterQueueNameRaw | read-write | current | Specify the name of the print queue (in RAW mode). |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1.1.5 | ColumnprinterQueueNameASCII | read-write | current | Specify the name of the print queue (in ASCII mode). |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.7.1.1.6 | ColumnprinterAppendFromFeed | read-write | current | Specify paging. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8 | Nodedial | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1 | TabledialTable | not-accessible | current | The Dial In/Out table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1 | RowdialEntry | not-accessible | current | The Dial In/Out entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.1 | ColumndialTERMBINMode | read-write | current | Select Yes to enable a Binary Terminal connection. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.2 | ColumndialPPPDMode | read-write | current | Select Yes to enable a PPPD connection. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.3 | ColumndialSLIPDMode | read-write | current | Select Yes to enable a SLIPD Terminal connection. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.4 | ColumndialAuthType | read-write | current | The dial in/out authentication type. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.5 | ColumndialDisconnectBy | read-write | current | If this field is set to 'dcd-off,' the connection will be disconnected when the DCD signal is off. If this field is set to 'dsr-off,' the connection will be di… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.6 | ColumndialDestinationIpAddress | read-write | current | Destination IP address is the IP address of the remote dial-in/dial-out server. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.7 | ColumndialSourceIpAddress | read-write | current | Source IP address is IP address of this serial port. The NPort 6000 series device server will automatically assign an IP address for the port. We recommend lea… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.8 | ColumndialIpNetmask | read-write | current | The IP netmask used for dial-in/dial-out networks (PPP or SLIP). |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.9 | ColumndialTcpIpCompression | read-write | current | Depends on whether the remote user's application requests compression. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.10 | ColumndialInactivityTime | read-write | current | 0 ms: TCP connection will not be closed if the serial line becomes idle. 1-65535 ms: The NPort 6000 series device server automatically closes the TCP connectio… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.11 | ColumndialLinkQualityReport | read-write | current | Choose YES if you are using software to collect Link quality information. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.12 | ColumndialOutgoingPAPID | read-write | current | Dial-out user ID account. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.13 | ColumndialPAPPassword | read-write | current | Dial-out user password. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.2.8.1.1.14 | ColumndialIncomingPAPCheck | read-write | current | The Dial in/out incoming PAP check type. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3 | NodedataPacking | |||
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1 | TabledataPackingPortTable | not-accessible | current | The Data Packing table. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1 | RowdataPackingPortEntry | not-accessible | current | The Data Packing entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1.1 | ColumnportPacketLength | read-write | current | If the value is 0, the Delimiter Process will be used, regardless of the length of the data packet. If the data length (in bytes) matches the configured value,… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1.2 | ColumnportDelimiter1Enable | read-write | current | Enable the first delimiter character. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1.3 | ColumnportDelimiter1 | read-write | current | The first delimiter character, in hex decimal. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1.4 | ColumnportDelimiter2Enable | read-write | current | Enable the second delimiter character. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1.5 | ColumnportDelimiter2 | read-write | current | The second delimiter character, in hex decimal. |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1.6 | ColumnportDelimiterProcess | read-write | current | 'delimiterAddOne' or 'delimiterAddTwo': The data will be transmitted when an additional byte (for 'delimiterAddOne'), or an additional 2 bytes (for 'delimiterA… |
| 1.3.6.1.4.1.8691.2.8.1.4.1.3.1.1.7 | ColumnportForceTransmit | read-write | current | 0: Disable the force transmit timeout. 1 to 65535: Forces the NPort 6000 series device server's TCP/IP protocol software to try to pack serial data received du… |
| 1.3.6.1.4.1.8691.2.8.1.4.2 | NodecomParamSetting | |||
| 1.3.6.1.4.1.8691.2.8.1.4.2.1 | TablecomParamPortTable | not-accessible | current | The Communication Parameters table. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1 | RowcomParamPortEntry | not-accessible | current | The Communication Parameters entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.1 | ColumnportAlias | read-write | current | Port alias is included to allow easy identification of the serial devices that are connected to NPort 6000 series device server's serial port. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.2 | ColumnportInterface | read-write | current | The serial interface that the port works on. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.3 | ColumnportBaudRate | read-write | current | The port's speed in bits per second. You can choose a standard baud rate by indexing. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.4 | ColumnportBaudRateManual | read-write | current | The port's speed in bits per second. You can specify a baud rate manually. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.5 | ColumnportDataBits | read-write | current | The number of bits in a character for the port. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.6 | ColumnportStopBits | read-write | current | The number of stop bits for the port. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.7 | ColumnportParity | read-write | current | The parity bit for the port. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.8 | ColumnportFlowControl | read-write | current | The flow-control method for the port. |
| 1.3.6.1.4.1.8691.2.8.1.4.2.1.1.9 | ColumnportFIFO | read-write | current | Enable or disable the port's FIFO. |
| 1.3.6.1.4.1.8691.2.8.1.4.3 | NodedataBuffering | |||
| 1.3.6.1.4.1.8691.2.8.1.4.3.1 | TabledataBufferingPortTable | not-accessible | current | The Data Buffering/Log table. |
| 1.3.6.1.4.1.8691.2.8.1.4.3.1.1 | RowdataBufferingPortEntry | not-accessible | current | The Data Buffering/Log entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.3.1.1.1 | ColumnportBufferingEnable | read-write | current | Enable off-line port buffering. |
| 1.3.6.1.4.1.8691.2.8.1.4.3.1.1.2 | ColumnportBufferingLocation | read-write | current | The location of off-line port buffering. |
| 1.3.6.1.4.1.8691.2.8.1.4.3.1.1.3 | ColumnportBufferingSDFileSize | read-write | current | The maximum file size of off-line port buffering, in MBytes, if the location is set to 'sdCard.' |
| 1.3.6.1.4.1.8691.2.8.1.4.3.1.1.4 | ColumnportSerialDataLoggingEnable | read-write | current | Enable or disable serial data logging for the port. |
| 1.3.6.1.4.1.8691.2.8.1.4.4 | NodemodemSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.4.4.1 | TablemodemSettingsPortTable | not-accessible | current | The Modem Settings table. |
| 1.3.6.1.4.1.8691.2.8.1.4.4.1.1 | RowmodemSettingsPortEntry | not-accessible | current | The Modem Settings entry. |
| 1.3.6.1.4.1.8691.2.8.1.4.4.1.1.1 | ColumnportEnableModem | read-write | current | Enable or disable modem for this port. |
| 1.3.6.1.4.1.8691.2.8.1.4.4.1.1.2 | ColumnportInitialString | read-write | current | Set the modem's initial string to establish the connection. E.g., 'AT&S0=1' for auto-answer. |
| 1.3.6.1.4.1.8691.2.8.1.4.4.1.1.3 | ColumnportDialUp | read-write | current | Set the modem's dial-up AT command string. |
| 1.3.6.1.4.1.8691.2.8.1.4.4.1.1.4 | ColumnportPhoneNumber | read-write | current | Set the number used to dial out. |
| 1.3.6.1.4.1.8691.2.8.1.4.5 | NodewelcomeMessage | |||
| 1.3.6.1.4.1.8691.2.8.1.4.5.1 | ScalarportEnableWelcomeMessage | read-write | current | Enable or disable the welcome message. |
| 1.3.6.1.4.1.8691.2.8.1.4.5.2 | ScalarportMessage | read-write | current | Set up a welcome message to greet dial-in users. |
| 1.3.6.1.4.1.8691.2.8.1.5 | NodesysManagement | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1 | NodemiscNetworkSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.1 | NodeaccessibleIp | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.1.1 | ScalarenableAccessibleIpList | read-write | current | Enable or disable the entire accessible IP list. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.1.2 | TableaccessibleIpListTable | not-accessible | current | Accessible IP List table. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.1.2.1 | RowaccessibleIpListEntry | not-accessible | current | Accessible IP List entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.1.2.1.1 | ColumnaccessibleIpListIndex | read-only | current | Accessible IP List index. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.1.2.1.2 | ColumnactiveAccessibleIpList | read-write | current | Enable or disable this accessible IP entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.1.2.1.3 | ColumnaccessibleIpListAddress | read-write | current | Accessible IP address. This value can be the IP address of a single host if the netmask is set to '255.255.255.255,' or it can be a network address. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.1.2.1.4 | ColumnaccessibleIpListNetmask | read-write | current | Accessible IP address netmask. The IP address and netmask are used to specify a group of remote hosts. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.2 | NodesnmpAgentSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.2.1 | ScalarsnmpEnable | read-write | current | Enable or disable SNMP agent. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.2.2 | ScalarsnmpContactName | read-write | current | The SNMP contact information usually includes an emergency contact name and telephone or pager number. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.2.3 | ScalarsnmpLocation | read-write | current | Specify the location string for SNMP agents, such as the NPort 6000 series device server. This string is usually set to the street address where the NPort 6000… |
| 1.3.6.1.4.1.8691.2.8.1.5.1.3 | NodedDNS | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.3.1 | ScalardDNSEnable | read-write | current | Enable or disable the DDNS function. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.3.2 | ScalardDNSServerAddress | read-write | current | The DDNS server address. The DDNS is serviced by a 3-party provider. To use the DDNS function, you may need to obtain a user account from the server. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.3.3 | ScalardDNSHostName | read-write | current | The host name of the machine to be registered to the DDNS server. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.3.4 | ScalardDNSUserName | read-write | current | The user account provided by the DDNS server. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.3.5 | ScalardDNSPassword | read-write | current | The user password provided by the DDNS server. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.4 | NodehostTable | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.4.1 | TablehostTableTable | not-accessible | current | Host Table. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.4.1.1 | RowhostTableEntry | not-accessible | current | Host Table entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.4.1.1.1 | ColumnhostTableIndex | read-only | current | The Host Table index. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.4.1.1.2 | ColumnhostName | read-write | current | The host name of the host table entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.4.1.1.3 | ColumnhostIpAddress | read-write | current | Related IP address of the host table entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5 | NoderouteTable | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1 | TablerouteTableTable | not-accessible | current | Route Table. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1.1 | RowrouteTableEntry | not-accessible | current | Route Table entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1.1.1 | ColumnrouteTableIndex | read-only | current | The Route Table index. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1.1.2 | ColumngatewayRouteTable | read-write | current | The gateway property of the route table entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1.1.3 | ColumndestinationRouteTable | read-write | current | The destination IP address of the route table entry. This value can be the IP address of a single host if the netmask set to '255.255.255.255,' or it can be a … |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1.1.4 | ColumnnetmaskRouteTable | read-write | current | The destination netmask of the route table entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1.1.5 | ColumnmetricRouteTable | read-write | current | The routing metric for this route. The semantics of this metric are determined by the routing-protocol. Normally, it represents the cost for the destination. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.5.1.1.6 | ColumninterfaceRouteTable | read-write | current | The value that identifies the local interface through which the next hop of this route should be reached. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.6 | NodeuserTable | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.6.1 | TableuserTableTable | not-accessible | current | User Table. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.6.1.1 | RowuserTableEntry | not-accessible | current | User Table entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.6.1.1.1 | ColumnuserTableIndex | read-only | current | The User Table index. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.6.1.1.2 | ColumnuserNameUserTable | read-write | current | The user name of this entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.6.1.1.3 | ColumnpasswordUserTable | read-write | current | The password of this user entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.6.1.1.4 | ColumnphoneNumberUserTable | read-write | current | The phone number of this user entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.7 | NodeauthenticationServer | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.7.1 | ScalarradiusServerIp | read-write | current | The IP address or domain name of the RADIUS server. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.7.2 | ScalarradiusKey | read-write | current | RADIUS password. Must be the same as in the RADIUS server. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.7.3 | ScalarudpPortAuthenticationServer | read-write | current | The UDP port of the RADIUS server. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.7.4 | ScalarradiusAccounting | read-write | current | Enable or disable RADIUS accounting. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.8 | NodesysLogSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.5.1.8.1 | ScalarsysLocalLog | read-write | current | Log the following events to the system log: System Cold Start, System Warm Start. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.8.2 | ScalarnetworkLocalLog | read-write | current | Log the following events to the system log: DHCP/BOOTP/PPPoE Get IP/Renew, NTP, Mail Fail, NTP Connect Fail, DHCP Fail, IP Conflict, Ethernet Link Down. |
| 1.3.6.1.4.1.8691.2.8.1.5.1.8.3 | ScalarconfigLocalLog | read-write | current | Log the following events to the system log: Login Fail, IP Changed, Password Changed, Config Changed, Firmware Upgrade, SSL Key Import, Config Import, Config E… |
| 1.3.6.1.4.1.8691.2.8.1.5.1.8.4 | ScalaropModeLocalLog | read-write | current | Log the following op-mode events to the system log: Connect, Disconnect, Authentication Fail, Restart. |
| 1.3.6.1.4.1.8691.2.8.1.5.2 | NodeautoWarningSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.5.2.1 | NodeeventSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.1 | ScalarmailWarningColdStart | read-write | current | Refers to starting the system from power off (contrast this with warm start). When performing a cold start, the NPort 6000 series device server will automatica… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.2 | ScalarmailWarningWarmStart | read-write | current | Refers to restarting the NPort 6000 without turning the power off. When performing a warm start, the NPort 6000 series device server will automatically send an… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.3 | ScalarmailWarningAuthFailure | read-write | current | The user inputs a wrong password from the Console or Administrator. When authentication failure occurs, the NPort 6000 series device server will immediately se… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.4 | ScalarmailWarningIpChanged | read-write | current | The user has changed the NPort 6000 series device server's IP address. When the IP address changes, the NPort 6000 series device server will send an e-mail wit… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.5 | ScalarmailWarningPasswordChanged | read-write | current | The user has changed the NPort 6000 series device server's password. When the password changes, the NPort 6000 series device server will send an e-mail with th… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.6 | ScalartrapServerColdStart | read-write | current | Refers to starting the system from power off (contrast this with warm start). When performing a cold start, the NPort 6000 series device server will automatica… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.7 | ScalartrapServerWarmStart | read-write | current | Refers to restarting the NPort 6000 without turning the power off. When performing a warm start, the NPort 6000 series device server will automatically send an… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.8 | ScalartrapServerAuthFailure | read-write | current | The user inputs a wrong password from the Console or Administrator. When authentication failure occurs, the NPort 6000 series device server will immediately se… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.9 | ScalaralarmServerEthernet1LinkDown | read-write | current | When the built-in link1 port is off, the NPort 6000 series device server will automatically raise a d-out alarm. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.10 | ScalaralarmServerEthernet2LinkDown | read-write | current | The NPort 6000 series device server can provide an extra Ethernet port via the network module. When the first port on the network module is off, the NPort 6000… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.1.11 | ScalaralarmServerEthernet3LinkDown | read-write | current | The NPort 6000 series device server can provide an extra Ethernet port via the network module. When the second port on the network module is off, the NPort 600… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2 | NodeserialEventSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1 | TableportEventSettingsTable | not-accessible | current | Port Event Settings Table. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1.1 | RowportEventSettingsEntry | not-accessible | current | Port Event Settings entry. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1.1.1 | ColumnmailDCDchange | read-write | current | A change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For example, if the DCD signal changes to low, it indi… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1.1.2 | ColumntrapDCDchange | read-write | current | A change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For example, if the DCD signal changes to low, it indi… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1.1.3 | ColumnalarmDCDchange | read-write | current | A change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For example, if the DCD signal changes to low, it indi… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1.1.4 | ColumnmailDSRchange | read-write | current | A change in the DSR (Data Set Ready) signal indicates that the data communication equipment is powered off. For example, if the DSR signal changes to low, it i… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1.1.5 | ColumntrapDSRchange | read-write | current | A change in the DSR (Data Set Ready) signal indicates that the data communication equipment is powered off. For example, if the DSR signal changes to low, it i… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.2.1.1.6 | ColumnalarmDSRchange | read-write | current | A change in the DSR (Data Set Ready) signal indicates that the data communication equipment is powered off. For example, if the DSR signal changes to low, it i… |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3 | NodeemailAlert | |||
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.1 | ScalaremailWarningMailServer | read-write | current | The e-mail server's IP address or domain name of the e-mail warning function. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.2 | ScalaremailRequiresAuthentication | read-write | current | Set if the mail server requires user login. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.3 | ScalaremailWarningUserName | read-write | current | The user name used to log into the mail server if authentication is required. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.4 | ScalaremailWarningPassword | read-write | current | The password used to log into the mail server if authentication is required. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.5 | ScalaremailWarningFromEmail | read-write | current | The e-mail address to be filled in the 'From' field of the auto-warning e-mail. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.6 | ScalaremailWarningFirstEmailAddr | read-write | current | The first email address to where the auto-warning e-mail is to be sent. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.7 | ScalaremailWarningSecondEmailAddr | read-write | current | The second email address to where the auto-warning e-mail is to be sent. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.8 | ScalaremailWarningThirdEmailAddr | read-write | current | The third email address to where the auto-warning e-mail is to be sent. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.3.9 | ScalaremailWarningFourthEmailAddr | read-write | current | The fourth email address to where the auto-warning e-mail is to be sent. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.4 | NodesnmpTrap | |||
| 1.3.6.1.4.1.8691.2.8.1.5.2.4.1 | ScalarsnmpTrapReceiverIp | read-write | current | SNMP trap receiver IP address or domain name. |
| 1.3.6.1.4.1.8691.2.8.1.5.2.4.2 | ScalartrapVersion | read-write | current | SNMP trap version used for the auto-warning function. |
| 1.3.6.1.4.1.8691.2.8.1.5.3 | Nodemaintenance | |||
| 1.3.6.1.4.1.8691.2.8.1.5.3.1 | NodeconsoleSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.5.3.1.1 | ScalarhttpConsole | read-write | current | Enable or disable HTTP console. |
| 1.3.6.1.4.1.8691.2.8.1.5.3.1.2 | ScalarhttpsConsole | read-write | current | Enable or disable HTTPS console. |
| 1.3.6.1.4.1.8691.2.8.1.5.3.1.3 | ScalartelnetConsole | read-write | current | Enable or disable Telnet console. |
| 1.3.6.1.4.1.8691.2.8.1.5.3.1.4 | ScalarsshConsole | read-write | current | Enable or disable SSH console. |
| 1.3.6.1.4.1.8691.2.8.1.5.3.1.5 | ScalarlcmReadOnlyProtect | read-write | current | Enable or disable LCM read-only protection. If the LCM panel is under read-only protection, users can only view the configurations from the LCM panel. Otherwis… |
| 1.3.6.1.4.1.8691.2.8.1.5.3.1.6 | ScalarresetButtonFunction | read-write | current | Enable or disable reset button protection. You can disable the hardware reset button after the NPort 6000 series device server has been restarted for 60 second… |
| 1.3.6.1.4.1.8691.2.8.1.5.3.2 | NodeloadFactoryDefault | |||
| 1.3.6.1.4.1.8691.2.8.1.5.3.2.1 | ScalarloadFactoryDefaultSetting | write-only | current | This function will reset all of the NPort 6000 series device server's settings to the factory default values. Be aware that previous settings will be lost. Sel… |
| 1.3.6.1.4.1.8691.2.8.1.6 | NodesysStatus | |||
| 1.3.6.1.4.1.8691.2.8.1.6.1 | Nodes2eConnections | |||
| 1.3.6.1.4.1.8691.2.8.1.6.1.1 | TablemonitorRemoteIpTable | not-accessible | current | Serial to Network Connections Remote IP table. |
| 1.3.6.1.4.1.8691.2.8.1.6.1.1.1 | RowmonitorRemoteIpEntry | not-accessible | current | Serial to Network Connections Remote IP entry. |
| 1.3.6.1.4.1.8691.2.8.1.6.1.1.1.1 | ColumnremoteIpIndex | read-only | current | Serial to Network Connections Remote IP index. |
| 1.3.6.1.4.1.8691.2.8.1.6.1.1.1.2 | ColumnmonitorRemoteIp | read-only | current | The remote IP currently connecting to this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.2 | NodeserialPortStatus | |||
| 1.3.6.1.4.1.8691.2.8.1.6.2.1 | TablemonitorSerialPortStatusTable | not-accessible | current | Serial Port Status table. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1 | RowmonitorSerialPortStatusEntry | not-accessible | current | Serial Port Status entry. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.1 | ColumnmonitorTxCount | read-only | current | View the number of bytes transmitted from the port since the last time the port was initialized. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.2 | ColumnmonitorRxCount | read-only | current | View the number of bytes received by the port since the last time the port was initialized. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.3 | ColumnmonitorTxTotalCount | read-only | current | View the number of bytes transmitted from the port since the last time the system was initialized. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.4 | ColumnmonitorRxTotalCount | read-only | current | View the number of bytes received by the port since the last time the system was initialized. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.5 | ColumnmonitorDSR | read-only | current | View the current DSR status of this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.6 | ColumnmonitorDTR | read-only | current | View the current DTR status of this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.7 | ColumnmonitorRTS | read-only | current | View the current RTS status of this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.8 | ColumnmonitorCTS | read-only | current | View the current CTS status of this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.2.1.1.9 | ColumnmonitorDCD | read-only | current | View the current DCD status of this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.3 | NodeserialPortErrorCount | |||
| 1.3.6.1.4.1.8691.2.8.1.6.3.1 | TablemonitorSerialPortErrorCountTable | not-accessible | current | Serial Port Error Count table. |
| 1.3.6.1.4.1.8691.2.8.1.6.3.1.1 | RowmonitorSerialPortErrorCountEntry | not-accessible | current | Serial Port Error Count entry. |
| 1.3.6.1.4.1.8691.2.8.1.6.3.1.1.1 | ColumnmonitorErrorCountFrame | read-only | current | View the number of 'Frame' errors for this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.3.1.1.2 | ColumnmonitorErrorCountParity | read-only | current | View the number of 'Parity' errors for this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.3.1.1.3 | ColumnmonitorErrorCountOverrun | read-only | current | View the number of 'Overrun' errors for this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.3.1.1.4 | ColumnmonitorErrorCountBreak | read-only | current | View the number of 'Break' errors for this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.4 | NodeserialPortSettings | |||
| 1.3.6.1.4.1.8691.2.8.1.6.4.1 | TablemonitorSerialPortSettingsTable | not-accessible | current | Serial Port Settings table. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1 | RowmonitorSerialPortSettingsEntry | not-accessible | current | Serial Port Settings entry. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.1 | ColumnmonitorBaudRate | read-only | current | View the current baudrate of the port. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.2 | ColumnmonitorDataBits | read-only | current | View the number of bits per byte for the port. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.3 | ColumnmonitorStopBits | read-only | current | View the number of stop bits for the port. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.4 | ColumnmonitorParity | read-only | current | View the parity bit for the port. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.5 | ColumnmonitorRTSCTSFlowControl | read-only | current | View if the port is using RTS/CTS flow control. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.6 | ColumnmonitorXONXOFFFlowControl | read-only | current | View if the port is using XON/XOFF flow control. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.7 | ColumnmonitorDTRDSRFlowControl | read-only | current | View if the port is using DTR/DSR flow control. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.8 | ColumnmonitorFIFO | read-only | current | View FIFO status of this port. |
| 1.3.6.1.4.1.8691.2.8.1.6.4.1.1.9 | ColumnmonitorInterface | read-only | current | View the serial interface that the port is using. |
| 1.3.6.1.4.1.8691.2.8.1.6.5 | NoderelayOutputStatus | |||
| 1.3.6.1.4.1.8691.2.8.1.6.5.1 | ScalarrelayOutputEthernet1LinkDown | read-only | current | The relay dout status of the event that the built- in LAN port is off. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.2 | Scalarethernet1LinkDownAcknowledge | write-only | current | Acknowledge the event that the built-in LAN port is off. Acknowledgement will clear the d-out alarm before you can actually fix the problem. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.3 | ScalarrelayOutputEthernet2LinkDown | read-only | current | The relay dout status of the event that the first LAN port of the network module is off. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.4 | Scalarethernet2LinkDownAcknowledge | write-only | current | Acknowledge the event that the first LAN port of the network module is off. Acknowledgement will clear the d-out alarm before you can actually fix the problem. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.5 | ScalarrelayOutputEthernet3LinkDown | read-only | current | The relay dout status of the event that the second LAN port of the network module is off. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.6 | Scalarethernet3LinkDownAcknowledge | write-only | current | Acknowledge the event that the second LAN port of the network module is off. Acknowledgement will clear the d-out alarm before you can actually fix the problem. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.7 | TableportDCDChangedStatusTable | not-accessible | current | DCD changed table. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.7.1 | RowportDCDChangedStatusEntry | not-accessible | current | DCD changed entry. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.7.1.1 | ColumnportDCDChangedStatus | read-only | current | The relay dout status of the event that the DCD signal of the port is changed. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.7.1.2 | ColumnportDCDChangedAcknowledge | write-only | current | Acknowledge the event that the DCD signal of the port is changed. Acknowledgement will clear the d-out alarm before you can actually fix the problem. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.8 | TableportDSRChangedStatusTable | not-accessible | current | DSR changed Table. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.8.1 | RowportDSRChangedStatusEntry | not-accessible | current | DSR changed entry. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.8.1.1 | ColumnportDSRChangedStatus | read-only | current | The relay dout status of the event that the DSR signal of the port is changed. |
| 1.3.6.1.4.1.8691.2.8.1.6.5.8.1.2 | ColumnportDSRChangedAcknowledge | write-only | current | Acknowledge the event that the DSR signal of the port is changed. Acknowledgement will clear the d-out alarm before you can actually fix the problem. |
| 1.3.6.1.4.1.8691.2.8.1.7 | NodesaveConfiguration | |||
| 1.3.6.1.4.1.8691.2.8.1.7.1 | ScalarsaveConfig | write-only | current | Save the applied configuration to the NPort 6000 series device server. |
| 1.3.6.1.4.1.8691.2.8.1.8 | Noderestart | |||
| 1.3.6.1.4.1.8691.2.8.1.8.1 | ScalarrestartPorts | write-only | current | Restart serial port. Restarting will cause port reseting. |
| 1.3.6.1.4.1.8691.2.8.1.8.2 | ScalarrestartSystem | write-only | current | Restart the NPort 6000 series device server. Be sure to save all of your configuration changes before you restart the system. Otherwise, all of the changes wil… |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PortList | OCTET STRING | current | Each octet within this value specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents… |