MOXA-NPS8000-MIB

652 objects
The MIB module for Moxa NPort S8000 series specific information.
Imported Objects
SNMPv2-SMIenterprises IpAddress OBJECT-TYPE
SNMPv2-TCDateAndTime DisplayString MacAddress TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.8691Nodemoxa
1.3.6.1.4.1.8691.2Nodenport
1.3.6.1.4.1.8691.2.12Identitynps8000The MIB module for Moxa NPort S8000 series specific information.
1.3.6.1.4.1.8691.2.12.1NodeswMgmt
1.3.6.1.4.1.8691.2.12.1.1Nodeoverview
1.3.6.1.4.1.8691.2.12.1.1.1ScalarmodelNameread-onlycurrentNPort S8455 series: Combo switch/serial device with 4 serial ports, 3 Ethernet ports, 2 fiber ports. NPort S8458 series: Combo switch/serial device with 4 seri…
1.3.6.1.4.1.8691.2.12.1.1.2ScalarserialNoread-onlycurrentThe serial number of the NPort. Every NPort S8000 series device server is assigned a unique serial number before it is shipped.
1.3.6.1.4.1.8691.2.12.1.1.3ScalarfirmwareVersionread-onlycurrentThe version of the firmware currently running on the NPort.
1.3.6.1.4.1.8691.2.12.1.1.4ScalarviewIpAddrread-onlycurrentThe version of the firmware currently running on the NPort.
1.3.6.1.4.1.8691.2.12.1.1.5ScalarmacAddressread-onlycurrentThe MAC address of the NPort's Ethernet interface.
1.3.6.1.4.1.8691.2.12.1.1.6ScalarupTimeread-onlycurrentThe time (in human-readable notation) since the system was last re-initialized.
1.3.6.1.4.1.8691.2.12.1.2NodebasicSettings
1.3.6.1.4.1.8691.2.12.1.2.1NodegeneralSettings
1.3.6.1.4.1.8691.2.12.1.2.1.1ScalarserverNameread-writecurrentA text string used to identify the NPort.
1.3.6.1.4.1.8691.2.12.1.2.1.2ScalarserverLocationread-writecurrentA text string used to identify the location of the NPort. This option is useful for specifying the location or application of different NPort device servers.
1.3.6.1.4.1.8691.2.12.1.2.1.3ScalarserverDescriptionread-writecurrentserverDescription.
1.3.6.1.4.1.8691.2.12.1.2.1.4ScalarmaintainerContactInforead-writecurrentmaintainerContactInfo.
1.3.6.1.4.1.8691.2.12.1.2.1.5ScalargeneralSettingActiveread-writecurrentSubmit general setting.
1.3.6.1.4.1.8691.2.12.1.2.2NodetimeSetting
1.3.6.1.4.1.8691.2.12.1.2.2.1ScalarsysDateTimeread-writecurrentThe date time of system
1.3.6.1.4.1.8691.2.12.1.2.2.2NodedaylightSaving
1.3.6.1.4.1.8691.2.12.1.2.2.2.1ScalarstartMonthread-writecurrentSetting Start Month of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.2ScalarstartWeekread-writecurrentSetting Start Week of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.3ScalarstartDayread-writecurrentSetting Start Day of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.4ScalarstartHourread-writecurrentSetting Start Hour of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.5ScalarendMonthread-writecurrentSetting End Month of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.6ScalarendWeekread-writecurrentSetting End Week of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.7ScalarendDayread-writecurrentSetting End Day of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.8ScalarendHourread-writecurrentSetting End Hour of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.2.9ScalaroffsetHoursread-writecurrentSetting Offset Hours of Daylight Saving time
1.3.6.1.4.1.8691.2.12.1.2.2.3ScalartimeZoneread-writecurrentThe time-zone index of the NPort.
1.3.6.1.4.1.8691.2.12.1.2.2.4ScalartimeServer1read-writecurrentThe first time server
1.3.6.1.4.1.8691.2.12.1.2.2.5ScalartimeServer2read-writecurrentThe second time server
1.3.6.1.4.1.8691.2.12.1.2.2.6ScalarcalibratePeriodread-writecurrentThe period (seconds) that calibrate with time server
1.3.6.1.4.1.8691.2.12.1.2.2.7ScalartimeSettingActiveread-writecurrentSubmit time setting.
1.3.6.1.4.1.8691.2.12.1.2.3NodenetworkSettings
1.3.6.1.4.1.8691.2.12.1.2.3.1ScalarautoIPConfigread-writecurrentThe auto IP config.
1.3.6.1.4.1.8691.2.12.1.2.3.2ScalarserverIpAddrread-writecurrentThe IP Address of this server.
1.3.6.1.4.1.8691.2.12.1.2.3.3ScalarsubMaskread-writecurrentThe Subnet Mask of this server.
1.3.6.1.4.1.8691.2.12.1.2.3.4Scalargatewayread-writecurrentThe gateway of this server.
1.3.6.1.4.1.8691.2.12.1.2.3.5ScalardnsServer1IPAddrread-writecurrentThe first DNS Server address.
1.3.6.1.4.1.8691.2.12.1.2.3.6ScalardnsServer2IPAddrread-writecurrentThe first DNS Server address.
1.3.6.1.4.1.8691.2.12.1.2.3.7ScalartcpAliveChkTimeread-writecurrentThe TCP alive check time.
1.3.6.1.4.1.8691.2.12.1.2.3.8ScalarnetworkSettingActiveread-writecurrentSubmit network setting.
1.3.6.1.4.1.8691.2.12.1.3NodeportSetting
1.3.6.1.4.1.8691.2.12.1.3.1NodeopModeSetting
1.3.6.1.4.1.8691.2.12.1.3.1.1NodeopMode
1.3.6.1.4.1.8691.2.12.1.3.1.1.1TableopModePortTablenot-accessiblecurrentThe serial ports' operation mode table.
1.3.6.1.4.1.8691.2.12.1.3.1.1.1.1RowopModePortEntrynot-accessiblecurrentThe serial port's operation mode entry.
1.3.6.1.4.1.8691.2.12.1.3.1.1.1.1.1ColumnportIndexread-onlycurrentThe serial port index.
1.3.6.1.4.1.8691.2.12.1.3.1.1.1.1.2ColumnportModeread-writecurrentThe application of the serial port. Note that changing this setting may also change the operation mode.
1.3.6.1.4.1.8691.2.12.1.3.1.2Nodeapplication
1.3.6.1.4.1.8691.2.12.1.3.1.2.1Noderealcom
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1TablerealComTablenot-accessiblecurrentThe serial ports' operation mode table.
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1.1RowrealComEntrynot-accessiblecurrentThe serial port's operation mode entry.
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1.1.1ColumnrealcomMaxConnectionread-writecurrentMax connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specif…
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1.1.2ColumnrealcomIgnoreJammedIpread-writecurrentPreviously, when Max connection was set to a value greater than 1, and the serial device was transmitting data, if any one of the connected hosts stopped respo…
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1.1.3ColumnrealcomAllowDriverControlread-writecurrentIf Max connection is greater than 1, NPort will ignore driver control commands from all connected hosts. However, if you set Allow driver control to YES, contr…
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1.1.4ColumnrealcomConnectionDownRTSread-writecurrentFor some applications, serial devices must obtain the Ethernet link status by reading the RTS signal from the NPort S8000 series device server. If this setting…
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1.1.5ColumnrealcomConnectionDownDTRread-writecurrentFor some applications, serial devices must obtain the Ethernet link status by reading the DTR signal from the NPort S8000 series device server. If this setting…
1.3.6.1.4.1.8691.2.12.1.3.1.2.1.1.1.6ColumnrealcomTcpAliveChkTimeread-writecurrentThe TCP alive check time.
1.3.6.1.4.1.8691.2.12.1.3.1.2.2Noderfc2217
1.3.6.1.4.1.8691.2.12.1.3.1.2.2.1Tablerfc2217Tablenot-accessiblecurrentThe serial ports' operation mode table.
1.3.6.1.4.1.8691.2.12.1.3.1.2.2.1.1Rowrfc2217Entrynot-accessiblecurrentThe serial port's operation mode entry.
1.3.6.1.4.1.8691.2.12.1.3.1.2.2.1.1.1Columnrfc2217TcpPortread-writecurrentThe 'TCP port' is the TCP port that the NPort S8000 series device server uses to listen to connections, and that other devices must use to contact the NPort S8…
1.3.6.1.4.1.8691.2.12.1.3.1.2.2.1.1.2Columnrfc2217TcpAliveChkTimeread-writecurrentThe TCP alive check time.
1.3.6.1.4.1.8691.2.12.1.3.1.2.3NodetcpServer
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1TabletcpServerTablenot-accessiblecurrentThe serial ports' operation mode table.
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1RowtcpServerEntrynot-accessiblecurrentThe serial port's operation mode entry.
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.1ColumntcpServerInactivityTimeread-writecurrent0 ms: TCP connection is not closed when the serial line is idle. 1-65535 ms: The NPort S8000 series device server automatically closes the TCP connection if th…
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.2ColumntcpServerMaxConnectionread-writecurrentMax connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specif…
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.3ColumntcpServerIgnoreJammedIpread-writecurrentPreviously, when Max connection was set to a value greater than 1, and the serial device was transmitting data, if any one of the connected hosts stopped respo…
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.4ColumntcpServerAllowDriverControlread-writecurrentIf Max connection is greater than 1, NPort will ignore driver control commands from all connected hosts. However, if you set Allow driver control to YES, contr…
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.5ColumntcpServerTcpServerConnectionDownRTSread-writecurrentFor some applications, serial devices must obtain the Ethernet link status from the RTS signal sent by the NPort S8000 series device server. If this setting is…
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.6ColumntcpServerTcpServerConnectionDownDTRread-writecurrentFor some applications, serial devices must obtain the Ethernet link status from the DTR signal sent by the NPort S8000 series device server. If this setting is…
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.7ColumntcpServerTcpPortread-writecurrentThe 'TCP port' is the TCP port that the NPort S8000 series device server uses to listen to connections, and that other devices must use to contact the NPort S8…
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.8ColumntcpServerCmdPortread-writecurrentThe 'Command port' is a TCP port used to listen for IP-Serial Lib commands from the host. In order to prevent a TCP port conflict with other applications, the …
1.3.6.1.4.1.8691.2.12.1.3.1.2.3.1.1.9ColumntcpServerTcpAliveChkTimeread-writecurrentThe TCP alive check time.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4NodetcpClient
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1TabletcpClientTablenot-accessiblecurrentThe serial ports' operation mode table.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1RowtcpClientEntrynot-accessiblecurrentThe serial port's operation mode entry.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.1ColumntcpClientInactivityTimeread-writecurrent0 ms: TCP connection is not closed when the serial line is idle. 1-65535 ms: The NPort S8000 series device server automatically closes the TCP connection if th…
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.2ColumntcpClientIgnoreJammedIpread-writecurrentPreviously, when Max connection was set to a value greater than 1, and the serial device was transmitting data, if any one of the connected hosts stopped respo…
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.3ColumntcpClientDestinationAddress1read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this IP address.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.4ColumntcpClientDestinationPort1read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this TCP port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.5ColumntcpClientDestinationAddress2read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this IP address.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.6ColumntcpClientDestinationPort2read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this TCP port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.7ColumntcpClientDestinationAddress3read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this IP address.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.8ColumntcpClientDestinationPort3read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.9ColumntcpClientDestinationAddress4read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this IP address.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.10ColumntcpClientDestinationPort4read-writecurrentThe NPort S8000 series device server can connect actively to a remote host that has this port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.11ColumntcpClientDesignatedLocalPort1read-writecurrentThe local TCP port used to connect actively to the remote host.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.12ColumntcpClientDesignatedLocalPort2read-writecurrentThe local TCP port used to connect actively to the remote host.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.13ColumntcpClientDesignatedLocalPort3read-writecurrentThe local TCP port used to connect actively to the remote host.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.14ColumntcpClientDesignatedLocalPort4read-writecurrentThe local TCP port used to connect actively to the remote host.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.15ColumntcpClientConnectionControlread-writecurrentEvents that cause the TCP client to drop the connection.
1.3.6.1.4.1.8691.2.12.1.3.1.2.4.1.1.16ColumntcpClientTcpAliveChkTimeread-writecurrentThe TCP alive check time.
1.3.6.1.4.1.8691.2.12.1.3.1.2.5Nodeudp
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1TableudpTablenot-accessiblecurrentThe serial ports' operation mode table.
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1RowudpEntrynot-accessiblecurrentThe serial port's operation mode entry.
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.1ColumnudpDestinationAddress1Beginread-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and udpDestinatio…
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.2ColumnudpDestinationAddress1Endread-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between udpDestinationAddress1Begin and …
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.3ColumnudpDestinationPort1read-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts that have this port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.4ColumnudpDestinationAddress2Beginread-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and udpDestinatio…
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.5ColumnudpDestinationAddress2Endread-writecurrentThe NPort S8000 series device server can actively send UDP packets to the remote hosts whose IP addresses are in the range between udpDestinationAddress2Begin …
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.6ColumnudpDestinationPort2read-writecurrentThe NPort S8000 series device server can actively send UDP packets to the remote hosts that have this TCP port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.7ColumnudpDestinationAddress3Beginread-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and udpDestinatio…
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.8ColumnudpDestinationAddress3Endread-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between udpDestinationAddress3Begin and …
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.9ColumnudpDestinationPort3read-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts that have this TCP port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.10ColumnudpDestinationAddress4Beginread-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between this parameter and udpDestinatio…
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.11ColumnudpDestinationAddress4Endread-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts whose IP addresses are in the range between udpDestinationAddress4Begin and …
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.12ColumnudpDestinationPort4read-writecurrentThe NPort S8000 series device server can actively send UDP packets to remote hosts that have this TCP port number.
1.3.6.1.4.1.8691.2.12.1.3.1.2.5.1.1.13ColumnudpLocalListenPortread-writecurrentThe UDP port that the NPort S8000 series device server listens to and that other devices must use to contact the NPort S8000 series device server.
1.3.6.1.4.1.8691.2.12.1.3.1.3NodedataPacking
1.3.6.1.4.1.8691.2.12.1.3.1.3.1TabledataPackingPortTablenot-accessiblecurrentThe Data Packing table.
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1RowdataPackingPortEntrynot-accessiblecurrentThe Data Packing entry.
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1.1ColumnportPacketLengthread-writecurrentIf the value is 0, the Delimiter Process will be used, regardless of the length of the data packet. If the data length (in bytes) matches the configured value,…
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1.2ColumnportDelimiter1Enableread-writecurrentEnable the first delimiter character.
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1.3ColumnportDelimiter1read-writecurrentThe first delimiter character, in hex decimal.
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1.4ColumnportDelimiter2Enableread-writecurrentEnable the second delimiter character.
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1.5ColumnportDelimiter2read-writecurrentThe second delimiter character, in hex decimal.
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1.6ColumnportDelimiterProcessread-writecurrent'delimiterAddOne' or 'delimiterAddTwo': The data will be transmitted when an additional byte (for 'delimiterAddOne'), or an additional 2 bytes (for 'delimiterA…
1.3.6.1.4.1.8691.2.12.1.3.1.3.1.1.7ColumnportForceTransmitread-writecurrent0: Disable the force transmit timeout. 1 to 65535: Forces the NPort S8000 series device server's TCP/IP protocol software to try to pack serial data received d…
1.3.6.1.4.1.8691.2.12.1.3.1.4ScalaropModeSettingActiveread-writecurrentSubmit opMode setting for all of serial ports.
1.3.6.1.4.1.8691.2.12.1.3.2NodecomParamSetting
1.3.6.1.4.1.8691.2.12.1.3.2.1TablecomParamPortTablenot-accessiblecurrentThe Communication Parameters table.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1RowcomParamPortEntrynot-accessiblecurrentThe Communication Parameters entry.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.1ColumnportAliasread-writecurrentPort alias is included to allow easy identification of the serial devices that are connected to NPort S8000 series device server's serial port.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.2ColumnportBaudRateread-writecurrentThe port's speed in bits per second. You can choose a standard baud rate by indexing.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.3ColumnportDataBitsread-writecurrentThe number of bits in a character for the port.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.4ColumnportStopBitsread-writecurrentThe number of stop bits for the port.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.5ColumnportParityread-writecurrentThe parity bit for the port.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.6ColumnportFlowControlread-writecurrentThe flow-control method for the port.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.7ColumnportFIFOread-writecurrentEnable or disable the port's FIFO.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.8ColumnportInterfaceread-writecurrentThe serial interface that the port works on.
1.3.6.1.4.1.8691.2.12.1.3.2.1.1.9ColumnportBaudRateManualread-writecurrentThe port's speed in bits per second. You can specify a baud rate manually.
1.3.6.1.4.1.8691.2.12.1.3.2.2ScalarcomParamSettingActiveread-writecurrentSubmit communication parameters setting for all of serial ports.
1.3.6.1.4.1.8691.2.12.1.3.3NodeserialTosSetting
1.3.6.1.4.1.8691.2.12.1.3.3.1TableserialTosTablenot-accessiblecurrentThe Communication Parameters table.
1.3.6.1.4.1.8691.2.12.1.3.3.1.1RowserialTosEntrynot-accessiblecurrentThe Communication Parameters entry.
1.3.6.1.4.1.8691.2.12.1.3.3.1.1.1ColumnserialTosEnableread-writecurrentThe serial port TOS is enable or not.
1.3.6.1.4.1.8691.2.12.1.3.3.1.1.2ColumnserialTosValueread-writecurrentThe serial port TOS value, the last 2 bits not be used.
1.3.6.1.4.1.8691.2.12.1.3.3.2ScalarserialTosSettingActiveread-writecurrentSubmit serial Tos setting for all of serial ports.
1.3.6.1.4.1.8691.2.12.1.4NodeethernetSetting
1.3.6.1.4.1.8691.2.12.1.4.1NodeportSettings
1.3.6.1.4.1.8691.2.12.1.4.1.1TableportTablenot-accessiblecurrentThe port table.
1.3.6.1.4.1.8691.2.12.1.4.1.1.1RowportEntrynot-accessiblecurrentThe port entry.
1.3.6.1.4.1.8691.2.12.1.4.1.1.1.1ColumnportIndex-Ethread-onlycurrentThe port index.
1.3.6.1.4.1.8691.2.12.1.4.1.1.1.2ColumnportEnableread-writecurrentThis enable the port.
1.3.6.1.4.1.8691.2.12.1.4.1.1.1.3ColumnportDescread-onlycurrentThe port description
1.3.6.1.4.1.8691.2.12.1.4.1.1.1.4ColumnportNameread-writecurrentThe port Name
1.3.6.1.4.1.8691.2.12.1.4.1.1.1.5ColumnportSpeedread-writecurrentThe port speed and duplex.
1.3.6.1.4.1.8691.2.12.1.4.1.1.1.6ColumnportFDXFlowCtrlread-writecurrentThe port FDX Flow Control
1.3.6.1.4.1.8691.2.12.1.4.1.1.1.7ColumnportMDIread-writecurrentThe port MDI/MDIX.
1.3.6.1.4.1.8691.2.12.1.4.1.2ScalarportSettingActiveread-writecurrentSubmit all of ethernet port setting.
1.3.6.1.4.1.8691.2.12.1.4.2NodeportTrunking
1.3.6.1.4.1.8691.2.12.1.4.2.1TabletrunkSettingTablenot-accessiblecurrentPort Trunking Setting Table.
1.3.6.1.4.1.8691.2.12.1.4.2.1.1RowtrunkSettingEntrynot-accessiblecurrentPort Trunking Setting Entry.
1.3.6.1.4.1.8691.2.12.1.4.2.1.1.1ColumntrunkSettingIndexread-onlycurrentTrunking Group Index.
1.3.6.1.4.1.8691.2.12.1.4.2.1.1.2ColumntrunkTyperead-writecurrentTrunking Group Type.
1.3.6.1.4.1.8691.2.12.1.4.2.1.1.3ColumntrunkMemberPortsread-writecurrentTrunking Group Member Ports.
1.3.6.1.4.1.8691.2.12.1.4.2.2ScalarportTrunkingActiveread-writecurrentSubmit port trunkning setting.
1.3.6.1.4.1.8691.2.12.1.4.3NodecommRedundancy
1.3.6.1.4.1.8691.2.12.1.4.3.1ScalarprotocolOfRedundancySetupread-writecurrentThis set the redundancy protocol of this server.
1.3.6.1.4.1.8691.2.12.1.4.3.2NodespanningTree
1.3.6.1.4.1.8691.2.12.1.4.3.2.1ScalarspanningTreeBridgePriorityread-writecurrentThe bridge priority of spanning tree protocol.
1.3.6.1.4.1.8691.2.12.1.4.3.2.2ScalarspanningTreeHelloTimeread-writecurrentThe hello time of spanning tree protocol.
1.3.6.1.4.1.8691.2.12.1.4.3.2.3ScalarspanningTreeMaxAgeread-writecurrentThe max. age of spanning tree protocol.
1.3.6.1.4.1.8691.2.12.1.4.3.2.4ScalarspanningTreeForwardingDelayread-writecurrentTje forwarding delay of spanning tree protocol.
1.3.6.1.4.1.8691.2.12.1.4.3.2.5TablespanningTreeTablenot-accessiblecurrentThe spanning tree table.
1.3.6.1.4.1.8691.2.12.1.4.3.2.5.1RowspanningTreeEntrynot-accessiblecurrentThe spanning tree port entry.
1.3.6.1.4.1.8691.2.12.1.4.3.2.5.1.1ColumnspanningTreeIndexread-onlycurrentThe index of spanning tree table.
1.3.6.1.4.1.8691.2.12.1.4.3.2.5.1.2ColumnenableSpanningTreeread-writecurrentThis enable of spanning tree protocol for this port.
1.3.6.1.4.1.8691.2.12.1.4.3.2.5.1.3ColumnspanningTreePortPriorityread-writecurrentThe port priority of spanning tree protocol.
1.3.6.1.4.1.8691.2.12.1.4.3.2.5.1.4ColumnspanningTreePortCostread-writecurrentThe port cost of spanning tree protocol.
1.3.6.1.4.1.8691.2.12.1.4.3.3NodeturboRing
1.3.6.1.4.1.8691.2.12.1.4.3.3.1ScalarturboRingMasterSetupread-writecurrentSet this to be Master.
1.3.6.1.4.1.8691.2.12.1.4.3.3.2ScalarturboRingRdntPort1read-writecurrentThe port number of 1st Redundant Port on the TURBO RING.
1.3.6.1.4.1.8691.2.12.1.4.3.3.3ScalarturboRingRdntPort2read-writecurrentThe port number of 2nd Redundant Port on the TURBO RING.
1.3.6.1.4.1.8691.2.12.1.4.3.3.4ScalarturboRingEnableCouplingread-writecurrentThis enable the ring coupling function.
1.3.6.1.4.1.8691.2.12.1.4.3.3.5ScalarturboRingCouplingPortread-writecurrentThe coupling port of ring coupling function.
1.3.6.1.4.1.8691.2.12.1.4.3.3.6ScalarturboRingControlPortread-writecurrentThe control port of ring coupling function.
1.3.6.1.4.1.8691.2.12.1.4.3.4NodeturboRingV2
1.3.6.1.4.1.8691.2.12.1.4.3.4.1NodeturboRingV2Ring1
1.3.6.1.4.1.8691.2.12.1.4.3.4.1.1ScalarringIndexRing1read-onlycurrentThe turboRingV2 Ring Index.
1.3.6.1.4.1.8691.2.12.1.4.3.4.1.2ScalarringEnableRing1read-writecurrentThe turboRingV2 Ring1 Enalbe Config.
1.3.6.1.4.1.8691.2.12.1.4.3.4.1.3ScalarmasterSetupRing1read-writecurrentIs this a Master or Slave.
1.3.6.1.4.1.8691.2.12.1.4.3.4.1.4Scalarrdnt1stPortRing1read-writecurrentThe port number of 1st Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.4.3.4.1.5Scalarrdnt2ndPortRing1read-writecurrentThe port number of 2nd Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.4.3.4.2NodeturboRingV2Ring2
1.3.6.1.4.1.8691.2.12.1.4.3.4.2.1ScalarringIndexRing2read-onlycurrentThe turboRingV2 Ring Index.
1.3.6.1.4.1.8691.2.12.1.4.3.4.2.2ScalarringEnableRing2read-writecurrentThe turboRingV2 Ring2 Enalbe Config.
1.3.6.1.4.1.8691.2.12.1.4.3.4.2.3ScalarmasterSetupRing2read-writecurrentIs this a Master or Slave.
1.3.6.1.4.1.8691.2.12.1.4.3.4.2.4Scalarrdnt1stPortRing2read-writecurrentThe port number of 1st Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.4.3.4.2.5Scalarrdnt2ndPortRing2read-writecurrentThe port number of 2nd Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.4.3.4.3NodeturboRingV2Coupling
1.3.6.1.4.1.8691.2.12.1.4.3.4.3.1ScalarcouplingEnableread-writecurrentSetting the ring coupling enable.
1.3.6.1.4.1.8691.2.12.1.4.3.4.3.2ScalarcouplingModeread-writecurrentSetting the ring coupling mode.
1.3.6.1.4.1.8691.2.12.1.4.3.4.3.3Scalarcoupling1stPortread-writecurrentIf in 'DUAL HOMING' mode,port name is 'Primary port',If in 'COUPLING' mode,port name is 'Coupling port'
1.3.6.1.4.1.8691.2.12.1.4.3.4.3.4Scalarcoupling2ndPortread-writecurrentIf in 'DUAL HOMING' mode,port name is 'Backup port',If in 'COUPLING' mode,port name is no used.
1.3.6.1.4.1.8691.2.12.1.4.3.5ScalarcommRedundancyActiveread-writecurrentSubmit communication redundancy setting.
1.3.6.1.4.1.8691.2.12.1.4.3.6NodeturboChain
1.3.6.1.4.1.8691.2.12.1.4.3.6.1ScalarturboChainRoleread-writecurrentThe device's role in Turbo Chain.
1.3.6.1.4.1.8691.2.12.1.4.3.6.2ScalarturboChainPort1read-writecurrentIf the device's role is Head, this variable assigns the Head Port. If the device's role is Member, this variable assigns the first Member Port. If the device's…
1.3.6.1.4.1.8691.2.12.1.4.3.6.3ScalarturboChainPort2read-writecurrentIf the device's role is Head, this variable assigns the Member Port. If the device's role is Member, this variable assigns the second Member Port. If the devic…
1.3.6.1.4.1.8691.2.12.1.4.4NoderateLimiting
1.3.6.1.4.1.8691.2.12.1.4.4.1TablerateLimitingTablenot-accessiblecurrentThe rate limiting table.
1.3.6.1.4.1.8691.2.12.1.4.4.1.1RowrateLimitingEntrynot-accessiblecurrentRate limiting Entry.
1.3.6.1.4.1.8691.2.12.1.4.4.1.1.1ColumnlimitModeread-writecurrentThe limit mode.
1.3.6.1.4.1.8691.2.12.1.4.4.1.1.2ColumnlowPriLimitRateread-writecurrentThe limiting rate of low priority queue.
1.3.6.1.4.1.8691.2.12.1.4.4.1.1.3ColumnnormalPriLimitRateread-writecurrentThe limiting rate of normal priority queue. The values being equal to or double value of lowPriLimitRate are valid for set.
1.3.6.1.4.1.8691.2.12.1.4.4.1.1.4ColumnmediumPriLimitRateread-writecurrentThe limiting rate of medium priority queue. The values being equal to or double value of normalPriLimitRate are valid for set.
1.3.6.1.4.1.8691.2.12.1.4.4.1.1.5ColumnhighPriLimitRateread-writecurrentThe limiting rate of high priority queue. The values being equal to or double value of mediumPriLimitRate are valid for set.
1.3.6.1.4.1.8691.2.12.1.4.4.2ScalarrateLimitActiveread-writecurrentSubmit rate limit setting.
1.3.6.1.4.1.8691.2.12.1.4.5NodelineSwapFastRecovery
1.3.6.1.4.1.8691.2.12.1.4.5.1ScalarlineSwapRecoveryread-writecurrentThis enable line-swap-fast-recovery function.
1.3.6.1.4.1.8691.2.12.1.4.5.2ScalarlineSwapActiveread-writecurrentSubmit line swap fast recovery setting.
1.3.6.1.4.1.8691.2.12.1.5NodeethernetAdvSetting
1.3.6.1.4.1.8691.2.12.1.5.1NodetrafficPrioritization
1.3.6.1.4.1.8691.2.12.1.5.1.1NodeqosClassification
1.3.6.1.4.1.8691.2.12.1.5.1.1.1ScalarqueuingMechanismread-writecurrentThe queuing mechanism.
1.3.6.1.4.1.8691.2.12.1.5.1.1.2TableqosPortTablenot-accessiblecurrentThe QOS port table.
1.3.6.1.4.1.8691.2.12.1.5.1.1.2.1RowqosPortEntrynot-accessiblecurrentThe QOS Port Entry.
1.3.6.1.4.1.8691.2.12.1.5.1.1.2.1.1ColumninspectTosread-writecurrentThis enable the inspection of TOS field.
1.3.6.1.4.1.8691.2.12.1.5.1.1.2.1.2ColumninspectCosread-writecurrentThis enable the inspection of COS field.
1.3.6.1.4.1.8691.2.12.1.5.1.1.2.1.3ColumnportPriorityread-writecurrentThe deault priority of the port.
1.3.6.1.4.1.8691.2.12.1.5.1.1.3ScalarqosClassificationActiveread-writecurrentSubmit Qos classification setting.
1.3.6.1.4.1.8691.2.12.1.5.1.2NodecosMapping
1.3.6.1.4.1.8691.2.12.1.5.1.2.1TablecosMappingTablenot-accessiblecurrentThe COS mapping table.
1.3.6.1.4.1.8691.2.12.1.5.1.2.1.1RowcosMappingEntrynot-accessiblecurrentThe COS mapping Entry.
1.3.6.1.4.1.8691.2.12.1.5.1.2.1.1.1ColumncosTagread-onlycurrentThe cos tag of TOS field.
1.3.6.1.4.1.8691.2.12.1.5.1.2.1.1.2ColumncosMappedPriorityread-writecurrentThe frame's priority corresponding to it's COS tag value.
1.3.6.1.4.1.8691.2.12.1.5.1.2.2ScalarcosMappingActiveread-writecurrentSubmit Cos mapping setting.
1.3.6.1.4.1.8691.2.12.1.5.1.3NodetosMapping
1.3.6.1.4.1.8691.2.12.1.5.1.3.1TabletosMappingTablenot-accessiblecurrentThe TOS mapping table.
1.3.6.1.4.1.8691.2.12.1.5.1.3.1.1RowtosMappingEntrynot-accessiblecurrentTOS mapping Entry.
1.3.6.1.4.1.8691.2.12.1.5.1.3.1.1.1ColumntosClassread-onlycurrentThe TOS class of TOS field.
1.3.6.1.4.1.8691.2.12.1.5.1.3.1.1.2ColumntosMappedPriorityread-writecurrentThe frame's priority corresponding to it's TOS class value.
1.3.6.1.4.1.8691.2.12.1.5.1.3.2ScalartosMappingActiveread-writecurrentSubmit TOS mapping setting.
1.3.6.1.4.1.8691.2.12.1.5.2Nodevlan
1.3.6.1.4.1.8691.2.12.1.5.2.1ScalarvlanTyperead-writecurrentVLAN Type.
1.3.6.1.4.1.8691.2.12.1.5.2.2ScalarmanagementVlanIdread-writecurrentThe management VLAN id.
1.3.6.1.4.1.8691.2.12.1.5.2.3TablevlanPortSettingTablenot-accessiblecurrentThe vlan seting table of ports.
1.3.6.1.4.1.8691.2.12.1.5.2.3.1RowvlanPortSettingEntrynot-accessiblecurrentPort Setting Entry of VLAN.
1.3.6.1.4.1.8691.2.12.1.5.2.3.1.1ColumnportVlanTyperead-writecurrentThe vlan type of port.
1.3.6.1.4.1.8691.2.12.1.5.2.3.1.2ColumnportDefaultVidread-writecurrentThe PVID of port.
1.3.6.1.4.1.8691.2.12.1.5.2.3.1.3ColumnportFixedVidread-writecurrentThe fixed vids of (trunk) port.
1.3.6.1.4.1.8691.2.12.1.5.2.3.1.4ColumnportForbiddenVidread-writecurrentThe forbidden vids of (trunk)port.
1.3.6.1.4.1.8691.2.12.1.5.2.4TableportbaseVlanSettingTablenot-accessiblecurrentPort base Vlan Setting Table.
1.3.6.1.4.1.8691.2.12.1.5.2.4.1RowportbaseVlanSettingEntrynot-accessiblecurrentPort base Vlan Setting Entry.
1.3.6.1.4.1.8691.2.12.1.5.2.4.1.1ColumnportbaseVlanSettingIndexread-onlycurrentport base Vlan Group Index.
1.3.6.1.4.1.8691.2.12.1.5.2.4.1.2ColumnportbaseVlanMemberPortsread-writecurrentport base Vlan Group Member Ports.
1.3.6.1.4.1.8691.2.12.1.5.2.5ScalarvlanActiveread-writecurrentSubmit VLAN setting.
1.3.6.1.4.1.8691.2.12.1.5.3NodemulticastFiltering
1.3.6.1.4.1.8691.2.12.1.5.3.1NodeigmpSnooping
1.3.6.1.4.1.8691.2.12.1.5.3.1.1ScalarenableGlobalIgmpSnoopingread-writecurrentThis enable the IGMP snooping functon .
1.3.6.1.4.1.8691.2.12.1.5.3.1.2ScalarquerierQueryIntervalread-writecurrentThis query interval of the querier function for this VLAN.
1.3.6.1.4.1.8691.2.12.1.5.3.1.3TableigmpSnoopingSettingTablenot-accessiblecurrentThe IGMP snooping setting table.
1.3.6.1.4.1.8691.2.12.1.5.3.1.3.1RowigmpSnoopingSettingEntrynot-accessiblecurrentThe IGMP snooping setting Entry.
1.3.6.1.4.1.8691.2.12.1.5.3.1.3.1.1ColumnenableIgmpSnoopingread-writecurrentThis enable the IGMP snooping functon in this VLAN.
1.3.6.1.4.1.8691.2.12.1.5.3.1.3.1.2ColumnenableQuerierread-writecurrentThis enable the querier function for this VLAN.
1.3.6.1.4.1.8691.2.12.1.5.3.1.3.1.3ColumnfixedMulticastQuerierPortsread-writecurrentThe ports that multicast-Querier exist.
1.3.6.1.4.1.8691.2.12.1.5.3.1.4ScalarigmpSnoopingActiveread-writecurrentSubmit GIMP snoopong setting.
1.3.6.1.4.1.8691.2.12.1.5.3.2NodestaticMulticast
1.3.6.1.4.1.8691.2.12.1.5.3.2.1TablestaticMulticastTablenot-accessiblecurrentThe static multicast table.
1.3.6.1.4.1.8691.2.12.1.5.3.2.1.1RowstaticMulticastEntrynot-accessiblecurrentStatic multicast Entry.
1.3.6.1.4.1.8691.2.12.1.5.3.2.1.1.1ColumnstaticMulticastIndexread-onlycurrentThe static multicast index.
1.3.6.1.4.1.8691.2.12.1.5.3.2.1.1.2ColumnstaticMulticastAddressread-createcurrentThe static multicast address.
1.3.6.1.4.1.8691.2.12.1.5.3.2.1.1.3ColumnstaticMulticastPortsread-createcurrentThe port map of the static multicast address.
1.3.6.1.4.1.8691.2.12.1.5.3.2.1.1.4ColumnstaticMulticastStatusread-createcurrentThe status is active to indicate normal. Use createAndGo to create new on multiple SET. Use createAndWait to create new on one SET all then actvie. Use destroy…
1.3.6.1.4.1.8691.2.12.1.5.3.3Nodegmrp
1.3.6.1.4.1.8691.2.12.1.5.3.3.1TablegmrpSettingTablenot-accessiblecurrentThe GMRP setting table.
1.3.6.1.4.1.8691.2.12.1.5.3.3.1.1RowgmrpSettingEntrynot-accessiblecurrentThe GMRP Setting Entry.
1.3.6.1.4.1.8691.2.12.1.5.3.3.1.1.1ColumnenableGMRPread-writecurrentEnable/Disable GMRP.
1.3.6.1.4.1.8691.2.12.1.5.3.3.2ScalargmrpActiveread-writecurrentSubmit GMRP setting.
1.3.6.1.4.1.8691.2.12.1.5.4NodesetDeviceIp
1.3.6.1.4.1.8691.2.12.1.5.4.1TablesetDevIpTablenot-accessiblecurrentThe set devvice IP table.
1.3.6.1.4.1.8691.2.12.1.5.4.1.1RowsetDevIpEntrynot-accessiblecurrentThe set devvice IP table entry.
1.3.6.1.4.1.8691.2.12.1.5.4.1.1.1ColumnsetDevIpIndexread-onlycurrentThe set devvice IP index.
1.3.6.1.4.1.8691.2.12.1.5.4.1.1.2ColumnsetDevIpCurrentIpofDeviceread-onlycurrentThe current IP address of connected to this port.
1.3.6.1.4.1.8691.2.12.1.5.4.1.1.3ColumnsetDevIpPresentByread-onlycurrentThe protocol used that assigning IP to the device.
1.3.6.1.4.1.8691.2.12.1.5.4.1.1.4ColumnsetDevIpDedicatedIpread-writecurrentThe IP address when assign to the device connected to this port.
1.3.6.1.4.1.8691.2.12.1.5.4.2ScalarsetDeviceIpActiveread-writecurrentSubmit automatic set device IP by DHCP/Bootp/RARP and DHCP relay agent setting.
1.3.6.1.4.1.8691.2.12.1.5.4.3ScalardhcpServer1read-writecurrentThe IP address1 of the relay agent.
1.3.6.1.4.1.8691.2.12.1.5.4.4ScalardhcpServer2read-writecurrentThe IP address2 of the relay agent.
1.3.6.1.4.1.8691.2.12.1.5.4.5ScalardhcpServer3read-writecurrentThe IP address3 of the relay agent.
1.3.6.1.4.1.8691.2.12.1.5.4.6ScalardhcpServer4read-writecurrentThe IP address4 of the relay agent.
1.3.6.1.4.1.8691.2.12.1.5.4.7NodeDHCPOption82
1.3.6.1.4.1.8691.2.12.1.5.4.7.1ScalarenableOption82read-writecurrentThe Option 82 information contains 2 sub-options: Circuit ID and Remote ID, which define the relationship between end device IP and the DHCP Option 82 server.
1.3.6.1.4.1.8691.2.12.1.5.4.7.2Scalaroption82Typeread-writecurrentThe type of DHCP option 82.
1.3.6.1.4.1.8691.2.12.1.5.4.7.3Scalaroption82Valueread-writecurrentThe value of DHCP option 82.
1.3.6.1.4.1.8691.2.12.1.5.4.7.4Scalaroption82Displayread-onlycurrentThe display of DHCP option 82.
1.3.6.1.4.1.8691.2.12.1.5.4.7.5TabledhcpFunctionTablenot-accessiblecurrentDHCP Function Table.
1.3.6.1.4.1.8691.2.12.1.5.4.7.5.1RowdhcpFunctionEntrynot-accessiblecurrentThe DHCP Function Table entry.
1.3.6.1.4.1.8691.2.12.1.5.4.7.5.1.1ColumndhcpPortIndexread-onlycurrentThe DHCP Function Table index.
1.3.6.1.4.1.8691.2.12.1.5.4.7.5.1.2ColumndhcpPortCirduitIDread-onlycurrentThe DHCP Function Table Cirduit-ID.
1.3.6.1.4.1.8691.2.12.1.5.4.7.5.1.3ColumndhcpPortO82enableread-writecurrentThe port enable of DHCP Function Table.
1.3.6.1.4.1.8691.2.12.1.6NodesystemManagement
1.3.6.1.4.1.8691.2.12.1.6.1NodemiscNetwork
1.3.6.1.4.1.8691.2.12.1.6.1.1NodeaccessibleIP
1.3.6.1.4.1.8691.2.12.1.6.1.1.1ScalarenableAccessibleIPread-writecurrentEnable the accessible IP address list.
1.3.6.1.4.1.8691.2.12.1.6.1.1.2TableaccessibleIpTablenot-accessiblecurrentaccessibleIP.
1.3.6.1.4.1.8691.2.12.1.6.1.1.2.1RowaccessibleIpEntrynot-accessiblecurrentAccessible IP address entry.
1.3.6.1.4.1.8691.2.12.1.6.1.1.2.1.1ColumnaccessibleIpIndexread-onlycurrentAccessible IP list index.
1.3.6.1.4.1.8691.2.12.1.6.1.1.2.1.2ColumnaccessibleIpAddressread-writecurrentAccessible IP address
1.3.6.1.4.1.8691.2.12.1.6.1.1.2.1.3ColumnaccessibleIpNetMaskread-writecurrentAccessible IP netmask.
1.3.6.1.4.1.8691.2.12.1.6.1.1.3ScalaraccessibleIPActiveread-writecurrentSubmit accessible IP list setting.
1.3.6.1.4.1.8691.2.12.1.6.1.2NodesyslogSetting
1.3.6.1.4.1.8691.2.12.1.6.1.2.1ScalarsyslogServer1read-writecurrentThe syslog server 1
1.3.6.1.4.1.8691.2.12.1.6.1.2.2ScalarsyslogServer1portread-writecurrentThe syslog server 1 port
1.3.6.1.4.1.8691.2.12.1.6.1.2.3ScalarsyslogServer2read-writecurrentThe syslog server 2
1.3.6.1.4.1.8691.2.12.1.6.1.2.4ScalarsyslogServer2portread-writecurrentThe syslog server 2 port
1.3.6.1.4.1.8691.2.12.1.6.1.2.5ScalarsyslogServer3read-writecurrentThe syslog server 3
1.3.6.1.4.1.8691.2.12.1.6.1.2.6ScalarsyslogServer3portread-writecurrentThe syslog server 3 port
1.3.6.1.4.1.8691.2.12.1.6.1.2.7ScalarsyslogSettingActiveread-writecurrentSubmit syslog server setting.
1.3.6.1.4.1.8691.2.12.1.6.2NodeportAccessControl
1.3.6.1.4.1.8691.2.12.1.6.2.1NodestaticPortLock
1.3.6.1.4.1.8691.2.12.1.6.2.1.1ScalarstaticPortLockAddressread-createcurrentThe static port lock address.
1.3.6.1.4.1.8691.2.12.1.6.2.1.2ScalarstaticPortLockPortread-createcurrentThe port of the static port lock address.
1.3.6.1.4.1.8691.2.12.1.6.2.1.3ScalarstaticPortLockStatusread-createcurrentThe status is active to indicate normal. Use createAndGo to create new on multiple SET.
1.3.6.1.4.1.8691.2.12.1.6.2.2Nodedot1x
1.3.6.1.4.1.8691.2.12.1.6.2.2.1ScalardataBaseOptionread-writecurrentSet IEEE 802.1X database option.
1.3.6.1.4.1.8691.2.12.1.6.2.2.2ScalarradiusServerread-writecurrentSet Radius Server IP Address/Domain name.
1.3.6.1.4.1.8691.2.12.1.6.2.2.3ScalarradiusPortread-writecurrentSet Radius Port.
1.3.6.1.4.1.8691.2.12.1.6.2.2.4ScalarradiusSharedKeyread-writecurrentSet Radius Shared Key.
1.3.6.1.4.1.8691.2.12.1.6.2.2.5Scalardot1xReauthEnableread-writecurrentEnable/Disable IEEE 802.1X Re-authentication.
1.3.6.1.4.1.8691.2.12.1.6.2.2.6Scalardot1xReauthPeriodread-writecurrentSet IEEE 802.1X Re-authentication Period.
1.3.6.1.4.1.8691.2.12.1.6.2.2.7Tabledot1xSettingTablenot-accessiblecurrentIEEE 802.1X Port Setting Table.
1.3.6.1.4.1.8691.2.12.1.6.2.2.7.1Rowdot1xSettingEntrynot-accessiblecurrentIEEE 802.1X Port Setting Entry.
1.3.6.1.4.1.8691.2.12.1.6.2.2.7.1.1ColumnenableDot1Xread-writecurrentEnable/Disable IEEE 802.1X.
1.3.6.1.4.1.8691.2.12.1.6.2.2.8Scalardot1xActiveread-writecurrentSubmit 802.1X setting.
1.3.6.1.4.1.8691.2.12.1.6.3NodeautoWarming
1.3.6.1.4.1.8691.2.12.1.6.3.1NodeemailAlert
1.3.6.1.4.1.8691.2.12.1.6.3.1.1ScalaremailWarningMailServerread-writecurrentThe email server's Ip Address/Domain name of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.1.2ScalaremailWarningFromEmailread-writecurrentThe e-mail address to be filled in the 'From' field of the auto-warning e-mail.
1.3.6.1.4.1.8691.2.12.1.6.3.1.3ScalaremailWarningFirstEmailAddrread-writecurrentThe first email address of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.1.4ScalaremailWarningSecondEmailAddrread-writecurrentThe second email address of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.1.5ScalaremailWarningThirdEmailAddrread-writecurrentThe third email address of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.1.6ScalaremailWarningFourthEmailAddrread-writecurrentThe fourth email address of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.1.7ScalaremailAlertActiveread-writecurrentSubmit EMail alert setting.
1.3.6.1.4.1.8691.2.12.1.6.3.2Nodesnmp
1.3.6.1.4.1.8691.2.12.1.6.3.2.1ScalarsnmpReadCommunityread-writecurrentThe SNMP read community name
1.3.6.1.4.1.8691.2.12.1.6.3.2.2ScalartrapServerAddr1read-writecurrentThe IP address/Domain name of SNMP trap server
1.3.6.1.4.1.8691.2.12.1.6.3.2.3ScalarsnmpTrapCommunity1read-writecurrentThe SNMP trap community name
1.3.6.1.4.1.8691.2.12.1.6.3.2.4Scalartrap2ServerAddrread-writecurrentThe IP address/Domain name of Second SNMP trap server
1.3.6.1.4.1.8691.2.12.1.6.3.2.5ScalarsnmpTrap2Communityread-writecurrentThe Second SNMP trap community name
1.3.6.1.4.1.8691.2.12.1.6.3.2.6ScalarsnmpActiveread-writecurrentSubmit SNMP setting.
1.3.6.1.4.1.8691.2.12.1.6.3.2.7ScalarSnmpInformEnableread-writecurrentEnable snmp inform.
1.3.6.1.4.1.8691.2.12.1.6.3.2.8ScalarSnmpInformRetriesread-writecurrentRetries of snmp inform.
1.3.6.1.4.1.8691.2.12.1.6.3.2.9ScalarSnmpInformTimeoutread-writecurrentTimeout of snmp inform.
1.3.6.1.4.1.8691.2.12.1.6.3.3NodeemailWarningEventType
1.3.6.1.4.1.8691.2.12.1.6.3.3.1ScalaremailWarningEventServerColdStartread-writecurrentThe server cold start event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.2ScalaremailWarningEventServerWarmStartread-writecurrentThe server warm start event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.3ScalaremailWarningEventPowerOn2Offread-writecurrentThe power on event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.4ScalaremailWarningEventPowerOff2Onread-writecurrentThe power off event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.5TableemailWarningEventDiTablenot-accessiblecurrentThe DI table of the email warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.5.1RowemailWarningEventDiEntrynot-accessiblecurrentThe DI table entry of the email warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.5.1.1ColumnemailWarningEventDiInputOn2Offread-writecurrentThe DI input off event of email warning function .
1.3.6.1.4.1.8691.2.12.1.6.3.3.5.1.2ColumnemailWarningEventDiInputOff2Onread-writecurrentThe DI input on event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.6ScalaremailWarningEventConfigChangeread-writecurrentThe configuration changed event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.7ScalaremailWarningEventAuthFailread-writecurrentThe authentication fail event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.8ScalaremailWarningEventTopologyChangedread-writecurrentThe communication redundancy topology changed event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.9TableemailWarningEventSerialPortTablenot-accessiblecurrentThe port table of the email warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.9.1RowemailWarningEventSerialPortEntrynot-accessiblecurrentThe port table entry of the email warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.9.1.1ColumnemailWarningEventSerailDCDChangeread-writecurrentA change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For example, if the DCD signal changes to low, it indi…
1.3.6.1.4.1.8691.2.12.1.6.3.3.9.1.2ColumnemailWarningEventSerailDSRChangeread-writecurrentA change in the DSR (Data Set Ready) signal indicates that the data communication equipment is powered off. For example, if the DSR signal changes to low, it i…
1.3.6.1.4.1.8691.2.12.1.6.3.3.10TableemailWarningEventEthernetPortTablenot-accessiblecurrentThe port table of the email warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.10.1RowemailWarningEventEthernetPortEntrynot-accessiblecurrentThe port table entry of the email warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.10.1.1ColumnemailWarningEventEthernetPortLinkOnread-writecurrentThe port link on event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.10.1.2ColumnemailWarningEventEthernetPortLinkOffread-writecurrentThe port link off event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.10.1.3ColumnemailWarningEventEthernetPortTrafficOverloadread-writecurrentThe port's traffic overloading event of email warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.3.10.1.4ColumnemailWarningEventEthernetPortTrafficThresholdread-writecurrentThe port's traffic threshold of the overloading event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.10.1.5ColumnemailWarningEventEthernetPortTrafficDurationread-writecurrentThe port's traffic duration of the overloading event.
1.3.6.1.4.1.8691.2.12.1.6.3.3.11ScalaremailWarningEventTypeActiveread-writecurrentSubmit Email event type setting.
1.3.6.1.4.1.8691.2.12.1.6.3.4NodesnmpWarningEventType
1.3.6.1.4.1.8691.2.12.1.6.3.4.1ScalarsnmpWarningEventServerColdStartread-writecurrentThe server cold start event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.2ScalarsnmpWarningEventServerWarmStartread-writecurrentThe server warm start event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.3ScalarsnmpWarningEventPowerOn2Offread-writecurrentThe power on event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.4ScalarsnmpWarningEventPowerOff2Onread-writecurrentThe power off event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.5TablesnmpWarningEventDiTablenot-accessiblecurrentThe DI table of the snmp warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.4.5.1RowsnmpWarningEventDiEntrynot-accessiblecurrentThe DI table entry of the snmp warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.4.5.1.1ColumnsnmpWarningEventDiInputOn2Offread-writecurrentThe DI input off event of snmp warning function .
1.3.6.1.4.1.8691.2.12.1.6.3.4.5.1.2ColumnsnmpWarningEventDiInputOff2Onread-writecurrentThe DI input on event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.6ScalarsnmpWarningEventConfigChangeread-writecurrentThe configuration changed event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.7ScalarsnmpWarningEventAuthFailread-writecurrentThe authentication fail event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.8ScalarsnmpWarningEventTopologyChangedread-writecurrentThe communication redundancy topology changed event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.9TablesnmpWarningEventSerailPortTablenot-accessiblecurrentPort Event Settings Table.
1.3.6.1.4.1.8691.2.12.1.6.3.4.9.1RowsnmpWarningEventSerailPortEntrynot-accessiblecurrentPort Event Settings entry.
1.3.6.1.4.1.8691.2.12.1.6.3.4.9.1.1ColumnsnmpWarningEventSerailDCDchangeread-writecurrentA change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For example, if the DCD signal changes to low, it indi…
1.3.6.1.4.1.8691.2.12.1.6.3.4.9.1.2ColumnsnmpWarningEventSerailDSRchangeread-writecurrentA change in the DSR (Data Set Ready) signal indicates that the data communication equipment is powered off. For example, if the DSR signal changes to low, it i…
1.3.6.1.4.1.8691.2.12.1.6.3.4.10TablesnmpWarningEventEthernetPortTablenot-accessiblecurrentThe port table of the snmp warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.4.10.1RowsnmpWarningEventEthernetPortEntrynot-accessiblecurrentThe port table entry of the snmp warning event.
1.3.6.1.4.1.8691.2.12.1.6.3.4.10.1.1ColumnsnmpWarningEventEthernetPortLinkOnread-writecurrentThe port link on event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.10.1.2ColumnsnmpWarningEventEthernetPortLinkOffread-writecurrentThe port link off event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.10.1.3ColumnsnmpWarningEventEthernetPortTrafficOverloadread-writecurrentThe port's traffic overloading event of snmp warning function.
1.3.6.1.4.1.8691.2.12.1.6.3.4.10.1.4ColumnsnmpWarningEventEthernetPortTrafficThresholdread-writecurrentThe port's traffic threshold of the overloading event.
1.3.6.1.4.1.8691.2.12.1.6.3.4.10.1.5ColumnsnmpWarningEventEthernetPortTrafficDurationread-writecurrentThe port's traffic duration of the overloading event.
1.3.6.1.4.1.8691.2.12.1.6.3.4.11ScalarsnmpWarningEventTypeActiveread-writecurrentSubmit SNMP event type setting.
1.3.6.1.4.1.8691.2.12.1.6.3.5NoderelayWarning
1.3.6.1.4.1.8691.2.12.1.6.3.5.1TablerelayWarningTablenot-accessiblecurrentThe relay warning table.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1RowrelayWarningEntrynot-accessiblecurrentRelay Warning Entry.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.1ColumnrelayAlarmIndexread-onlycurrentThe Relay alarm index.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.2ColumnrelayWarningRelayContactread-onlycurrentThe first Relay contact status.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.3ColumnoverrideRelayWarningSettingread-writecurrentOverride the relay warning setting.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.4ColumnrelayWarningPower1Offread-writecurrentThe relay contact will be opened while the first power input off.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.5ColumnrelayWarningPower1OffStatusread-onlycurrentThe relay contact is opened as the first power input off..
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.6ColumnrelayWarningPower2Offread-writecurrentThe relay contact will be opened while the second power input off.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.7ColumnrelayWarningPower2OffStatusread-onlycurrentThe relay contact is opened as the second power input off.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.8ColumnrelayWarningTurboRingBreakread-writecurrentThe relay contact will be opened while turbo ring break.
1.3.6.1.4.1.8691.2.12.1.6.3.5.1.1.9ColumnrelayWarningTurboRingBreakStatusread-onlycurrentThe relay contact is opened while turbo ring is broken.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2TableportRelayWarningTablenot-accessiblecurrentThe relay warning port table.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2.1RowportRelayWarningEntrynot-accessiblecurrentPort Relay Warning Entry.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2.1.1ColumnrelayWarningLinkChangedread-writecurrentThe relay contact will be opened while this port's link status is changed.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2.1.2ColumnrelayWarningLinkChangedStatusread-onlycurrentThe relay contact is opened as this port's link status is changed.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2.1.3ColumnrelayWarningTrafficOverloadread-writecurrentThe relay contact will be opened while this port's traffic is overload.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2.1.4ColumnrelayWarningTrafficOverloadStatusread-onlycurrentThe relay contact is opened as this port's traffic is overload.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2.1.5ColumnrelayWarningTrafficThresholdread-writecurrentThe threshold of the port traffic will be over loading.
1.3.6.1.4.1.8691.2.12.1.6.3.5.2.1.6ColumnrelayWarningTrafficDurationread-writecurrentThe duration of the port traffic will be over loading.
1.3.6.1.4.1.8691.2.12.1.6.3.5.3TablediRelayWarningTablenot-accessiblecurrentThe relay warning DI table.
1.3.6.1.4.1.8691.2.12.1.6.3.5.3.1RowdiRelayWarningEntrynot-accessiblecurrentDI Relay Warning Entry.
1.3.6.1.4.1.8691.2.12.1.6.3.5.3.1.1ColumnrelayWarningDiInputChangedread-writecurrentThe relay contact will be opened while the DI input changed.
1.3.6.1.4.1.8691.2.12.1.6.3.5.3.1.2ColumnrelayWarningDiInputChangedStatusread-onlycurrentThe relay contact is opened as the first DI input changed..
1.3.6.1.4.1.8691.2.12.1.6.3.5.4ScalarrelayWarningActiveread-writecurrentSubmit relay warring setting.
1.3.6.1.4.1.8691.2.12.1.6.3.6NodesysLogSettings
1.3.6.1.4.1.8691.2.12.1.6.3.6.1ScalarsysLocalLogread-writecurrentLog the following events to the system log: System Cold Start, System Warm Start.
1.3.6.1.4.1.8691.2.12.1.6.3.6.2ScalarnetworkLocalLogread-writecurrentLog the following events to the system log: DHCP/BOOTP/PPPoE Get IP/Renew, NTP, Mail Fail, NTP Connect Fail, DHCP Fail, IP Conflict, Ethernet Link Down.
1.3.6.1.4.1.8691.2.12.1.6.3.6.3ScalarconfigLocalLogread-writecurrentLog the following events to the system log: Login Fail, IP Changed, Password Changed, Config Changed, Firmware Upgrade, SSL Key Import, Config Import, Config E…
1.3.6.1.4.1.8691.2.12.1.6.3.6.4ScalaropModeLocalLogread-writecurrentLog the following op-mode events to the system log: Connect, Disconnect, Authentication Fail, Restart.
1.3.6.1.4.1.8691.2.12.1.6.3.6.5ScalarsysRemoteLogread-writecurrentLog the following events to the remote log server: System Cold Start, System Warm Start.
1.3.6.1.4.1.8691.2.12.1.6.3.6.6ScalarnetworkRemoteLogread-writecurrentLog the following events to the remote log server: DHCP/BOOTP/PPPoE Get IP/Renew, NTP, Mail Fail, NTP Connect Fail, DHCP Fail, IP Conflict, Ethernet Link Down.
1.3.6.1.4.1.8691.2.12.1.6.3.6.7ScalarconfigRemoteLogread-writecurrentLog the following events to the remote log server: Login Fail, IP Changed, Password Changed, Config Changed, Firmware Upgrade, SSL Key Import, Config Import, C…
1.3.6.1.4.1.8691.2.12.1.6.3.6.8ScalaropModeRemoteLogread-writecurrentLog the following op-mode events to the remote log server: Connect, Disconnect, Authentication Fail, Restart.
1.3.6.1.4.1.8691.2.12.1.6.3.6.9ScalarsysLogSettingsActiveread-writecurrentSubmit sysLog setting.
1.3.6.1.4.1.8691.2.12.1.6.4Nodemaintenance
1.3.6.1.4.1.8691.2.12.1.6.4.1NodeconsoleSetting
1.3.6.1.4.1.8691.2.12.1.6.4.1.1ScalarwebConsoleread-writecurrentEnable or disable Web console.
1.3.6.1.4.1.8691.2.12.1.6.4.1.2ScalarhttpConsoleread-writecurrentEnable or disable HTTP console.
1.3.6.1.4.1.8691.2.12.1.6.4.1.3ScalartelnetConsoleread-writecurrentEnable or disable Telnet console.
1.3.6.1.4.1.8691.2.12.1.6.4.1.4ScalarresetButtonFunctionread-writecurrentEnable or disable reset button protection. You can disable the hardware reset button after the NPort S8000 series device server has been restarted for 60 secon…
1.3.6.1.4.1.8691.2.12.1.6.4.1.5ScalarautoRefreshread-writecurrentMonitor refresh time.
1.3.6.1.4.1.8691.2.12.1.6.4.1.6ScalarconsoleSettingActiveread-writecurrentSubmit console setting.
1.3.6.1.4.1.8691.2.12.1.6.4.2NodeloadFactoryDefault
1.3.6.1.4.1.8691.2.12.1.6.4.2.1ScalarloadFactoryDefaultSettingread-writecurrentThis function will reset all of the NPort S8000 series device server's settings to the factory default values. Be aware that previous settings will be lost. Se…
1.3.6.1.4.1.8691.2.12.1.6.4.4Nodemirroring
1.3.6.1.4.1.8691.2.12.1.6.4.4.1ScalartargetPortread-writecurrentThe mirrored port of mirroring function.
1.3.6.1.4.1.8691.2.12.1.6.4.4.2ScalarmonitorDirectionread-writecurrentThe traffic direction of mirroring function.
1.3.6.1.4.1.8691.2.12.1.6.4.4.3ScalarmirroringPortread-writecurrentThe mirroring port of mirroring function.
1.3.6.1.4.1.8691.2.12.1.6.4.4.4ScalarmirroringActiveread-writecurrentSubmit mirroring setting.
1.3.6.1.4.1.8691.2.12.1.6.5NodesysFileUpdate
1.3.6.1.4.1.8691.2.12.1.6.5.1ScalartftpServerread-writecurrentThe TFTP Server name(IP Address)
1.3.6.1.4.1.8691.2.12.1.6.5.2ScalarconfPathNameread-writecurrentThe path name of configuration file in the TFTP Server
1.3.6.1.4.1.8691.2.12.1.6.5.3ScalarfirmwarePathNameread-writecurrentThe path name of firmware file in the TFTP Server
1.3.6.1.4.1.8691.2.12.1.6.5.4ScalarlogPathNameread-writecurrentThe path name of log file in the TFTP Server
1.3.6.1.4.1.8691.2.12.1.6.5.5ScalarsysFileUpdateActiveread-writecurrentSubmit sysFileUpdate setting.
1.3.6.1.4.1.8691.2.12.1.6.6NodedipSwitchSetting
1.3.6.1.4.1.8691.2.12.1.6.6.1ScalardipSwitchEnableTurboRingread-writecurrentEnable TurboRing Dip Switch functions
1.3.6.1.4.1.8691.2.12.1.6.6.2ScalardipSwitchTurboRingTyperead-writecurrentSet DIP switch
1.3.6.1.4.1.8691.2.12.1.6.6.3ScalardipSwitchSettingActiveread-writecurrentSubmit dip switch setting.
1.3.6.1.4.1.8691.2.12.1.6.7Nodelldp
1.3.6.1.4.1.8691.2.12.1.6.7.1ScalarlldpEnableread-writecurrentEnable LLDP function
1.3.6.1.4.1.8691.2.12.1.6.7.2ScalarlldpMsgTxIntervalread-writecurrentLLDP message transmit interval(valid range 5~32768)
1.3.6.1.4.1.8691.2.12.1.7NodesystemMonitoring
1.3.6.1.4.1.8691.2.12.1.7.1NodeserialStatus
1.3.6.1.4.1.8691.2.12.1.7.1.1Nodes2eConnections
1.3.6.1.4.1.8691.2.12.1.7.1.1.1TablemonitorRemoteIpTablenot-accessiblecurrentSerial to Network Connections Remote IP table.
1.3.6.1.4.1.8691.2.12.1.7.1.1.1.1RowmonitorRemoteIpEntrynot-accessiblecurrentSerial to Network Connections Remote IP entry.
1.3.6.1.4.1.8691.2.12.1.7.1.1.1.1.1ColumnremoteIpIndexread-onlycurrentSerial to Network Connections Remote IP index.
1.3.6.1.4.1.8691.2.12.1.7.1.1.1.1.2ColumnmonitorRemoteIpread-onlycurrentThe remote IP currently connecting to this port.
1.3.6.1.4.1.8691.2.12.1.7.1.2NodeserialPortStatus
1.3.6.1.4.1.8691.2.12.1.7.1.2.1TablemonitorSerialPortStatusTablenot-accessiblecurrentSerial Port Status table.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1RowmonitorSerialPortStatusEntrynot-accessiblecurrentSerial Port Status entry.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.1ColumnmonitorTxCountread-onlycurrentView the number of bytes transmitted from the port since the last time the port was initialized.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.2ColumnmonitorRxCountread-onlycurrentView the number of bytes received by the port since the last time the port was initialized.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.3ColumnmonitorTxTotalCountread-onlycurrentView the number of bytes transmitted from the port since the last time the system was initialized.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.4ColumnmonitorRxTotalCountread-onlycurrentView the number of bytes received by the port since the last time the system was initialized.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.5ColumnmonitorDSRread-onlycurrentView the current DSR status of this port.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.6ColumnmonitorDTRread-onlycurrentView the current DTR status of this port.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.7ColumnmonitorRTSread-onlycurrentView the current RTS status of this port.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.8ColumnmonitorCTSread-onlycurrentView the current CTS status of this port.
1.3.6.1.4.1.8691.2.12.1.7.1.2.1.1.9ColumnmonitorDCDread-onlycurrentView the current DCD status of this port.
1.3.6.1.4.1.8691.2.12.1.7.1.3NodeserialPortErrorCount
1.3.6.1.4.1.8691.2.12.1.7.1.3.1TablemonitorSerialPortErrorCountTablenot-accessiblecurrentSerial Port Error Count table.
1.3.6.1.4.1.8691.2.12.1.7.1.3.1.1RowmonitorSerialPortErrorCountEntrynot-accessiblecurrentSerial Port Error Count entry.
1.3.6.1.4.1.8691.2.12.1.7.1.3.1.1.1ColumnmonitorErrorCountFrameread-onlycurrentView the number of 'Frame' errors for this port.
1.3.6.1.4.1.8691.2.12.1.7.1.3.1.1.2ColumnmonitorErrorCountParityread-onlycurrentView the number of 'Parity' errors for this port.
1.3.6.1.4.1.8691.2.12.1.7.1.3.1.1.3ColumnmonitorErrorCountOverrunread-onlycurrentView the number of 'Overrun' errors for this port.
1.3.6.1.4.1.8691.2.12.1.7.1.3.1.1.4ColumnmonitorErrorCountBreakread-onlycurrentView the number of 'Break' errors for this port.
1.3.6.1.4.1.8691.2.12.1.7.1.4NodeserialPortSettings
1.3.6.1.4.1.8691.2.12.1.7.1.4.1TablemonitorSerialPortSettingsTablenot-accessiblecurrentSerial Port Settings table.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1RowmonitorSerialPortSettingsEntrynot-accessiblecurrentSerial Port Settings entry.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.1ColumnmonitorBaudRateread-onlycurrentView the current baudrate of the port.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.2ColumnmonitorDataBitsread-onlycurrentView the number of bits per byte for the port.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.3ColumnmonitorStopBitsread-onlycurrentView the number of stop bits for the port.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.4ColumnmonitorParityread-onlycurrentView the parity bit for the port.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.5ColumnmonitorRTSCTSFlowControlread-onlycurrentView if the port is using RTS/CTS flow control.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.6ColumnmonitorXONXOFFFlowControlread-onlycurrentView if the port is using XON/XOFF flow control.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.7ColumnmonitorFIFOread-onlycurrentView FIFO status of this port.
1.3.6.1.4.1.8691.2.12.1.7.1.4.1.1.8ColumnmonitorInterfaceread-onlycurrentView the serial interface that the port is using.
1.3.6.1.4.1.8691.2.12.1.7.2NodesystemStatus
1.3.6.1.4.1.8691.2.12.1.7.2.1NodesystemInfo
1.3.6.1.4.1.8691.2.12.1.7.2.1.1Scalarpower1InputStatusread-onlycurrentThe status of the first power input.
1.3.6.1.4.1.8691.2.12.1.7.2.1.2Scalarpower2InputStatusread-onlycurrentThe status of the second power input.
1.3.6.1.4.1.8691.2.12.1.7.2.1.3TablemonitorDiTablenot-accessiblecurrentThe DI table of monitor function.
1.3.6.1.4.1.8691.2.12.1.7.2.1.3.1RowmonitorDiEntrynot-accessiblecurrentThe DI table entry of monitor function.
1.3.6.1.4.1.8691.2.12.1.7.2.1.3.1.1ColumndiIndexread-onlycurrentThe DI index of monitor function
1.3.6.1.4.1.8691.2.12.1.7.2.1.3.1.2ColumndiInputStatusread-onlycurrentThe DI input status.
1.3.6.1.4.1.8691.2.12.1.7.2.1.4ScalardipSwitchTurboRingPoleread-onlycurrentThe TurboRing Pole status of Dip switch.
1.3.6.1.4.1.8691.2.12.1.7.2.1.5ScalardipSwitchRingCouplingPoleread-onlycurrentThe Ring Coupling Pole status of Dip switch.
1.3.6.1.4.1.8691.2.12.1.7.2.1.6ScalardipSwitchRingMasterPoleread-onlycurrentThe Ring Master Pole status of Dip switch.
1.3.6.1.4.1.8691.2.12.1.7.2.2NodenetworkConnected
1.3.6.1.4.1.8691.2.12.1.7.2.2.1TablenetworkConnTablenot-accessiblecurrentThe Port Access Control table.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1RownetworkConnEntrynot-accessiblecurrentThe Port Access Control table entry.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.1Columnprotocolread-onlycurrentConnected potocol.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.2Columnrecv-qread-onlycurrentReceiver queue size.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.3Columnsend-qread-onlycurrentSend queue size.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.4ColumnlocalIpAddressread-onlycurrentLocal IP Address.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.5ColumnlocalPortread-onlycurrentLocal port.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.6ColumnremoteIpAddressread-onlycurrentRemote IP Address.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.7ColumnremotePortread-onlycurrentRemote port.
1.3.6.1.4.1.8691.2.12.1.7.2.2.1.1.8Columnstateread-onlycurrentConnected state.
1.3.6.1.4.1.8691.2.12.1.7.2.3NodeeventLog
1.3.6.1.4.1.8691.2.12.1.7.2.3.1TableeventLogTablenot-accessiblecurrentThe Port Access Control table.
1.3.6.1.4.1.8691.2.12.1.7.2.3.1.1RoweventLogEntrynot-accessiblecurrentThe Port Access Control table entry.
1.3.6.1.4.1.8691.2.12.1.7.2.3.1.1.1ColumneventListIndexread-onlycurrentindex.
1.3.6.1.4.1.8691.2.12.1.7.2.3.1.1.2ColumneventListBootupread-onlycurrentindex.
1.3.6.1.4.1.8691.2.12.1.7.2.3.1.1.3ColumneventListDataread-onlycurrentindex.
1.3.6.1.4.1.8691.2.12.1.7.2.3.1.1.4ColumneventListTimeread-onlycurrentindex.
1.3.6.1.4.1.8691.2.12.1.7.2.3.1.1.5ColumneventListSysUpTimeread-onlycurrentindex.
1.3.6.1.4.1.8691.2.12.1.7.2.3.1.1.6ColumneventListEventread-onlycurrentindex.
1.3.6.1.4.1.8691.2.12.1.7.2.3.2ScalareventListClearread-writecurrentindex.
1.3.6.1.4.1.8691.2.12.1.7.3NodeethernetStatus
1.3.6.1.4.1.8691.2.12.1.7.3.1NodemacAddressList
1.3.6.1.4.1.8691.2.12.1.7.3.2Nodeigmpstatus
1.3.6.1.4.1.8691.2.12.1.7.3.2.1TableigmpSnoopingMulticastGroupTablenot-accessiblecurrentThe multicast group table by IGMP snooping function.
1.3.6.1.4.1.8691.2.12.1.7.3.2.1.1RowigmpSnoopingMulticastGroupEntrynot-accessiblecurrentThe multicast group entry by IGMP snooping function.
1.3.6.1.4.1.8691.2.12.1.7.3.2.1.1.1ColumnlearnedMulticastQuerierPortsread-onlycurrentThe ports that multicast-Querier exist.
1.3.6.1.4.1.8691.2.12.1.7.3.2.1.1.2ColumnigmpSnoopingIpGroupread-onlycurrentThe multicast IP group by IGMP snooping function.
1.3.6.1.4.1.8691.2.12.1.7.3.2.1.1.3ColumnigmpSnoopingMacGroupread-onlycurrentThe multicast MAC group by IGMP snooping function.
1.3.6.1.4.1.8691.2.12.1.7.3.2.1.1.4ColumnigmpSnoopingJoinedPortsread-onlycurrentThe ports that joined this multicast group.
1.3.6.1.4.1.8691.2.12.1.7.3.3NodegmrpStatus
1.3.6.1.4.1.8691.2.12.1.7.3.3.1TablegmrpTablenot-accessiblecurrentThe GMRP status table.
1.3.6.1.4.1.8691.2.12.1.7.3.3.1.1RowgmrpEntrynot-accessiblecurrentThe GMRP Status Entry.
1.3.6.1.4.1.8691.2.12.1.7.3.3.1.1.1ColumngmrpMulticastGroupread-onlycurrentGMRP multicast group.
1.3.6.1.4.1.8691.2.12.1.7.3.3.1.1.2ColumngmrpFixedPortsread-onlycurrentThe ports that joined GMRP multicast group manually.
1.3.6.1.4.1.8691.2.12.1.7.3.3.1.1.3ColumngmrpLearnedPortsread-onlycurrentThe ports that joined GMRP multicast group by GMRP learning.
1.3.6.1.4.1.8691.2.12.1.7.3.4Nodedot1XReauth
1.3.6.1.4.1.8691.2.12.1.7.3.4.1Tabledot1xReauthTablenot-accessiblecurrentIEEE 802.1X Re-authentication Table.
1.3.6.1.4.1.8691.2.12.1.7.3.4.1.1Rowdot1xReauthEntrynot-accessiblecurrentIEEE 802.1X Re-authentication Entry.
1.3.6.1.4.1.8691.2.12.1.7.3.4.1.1.1Columndot1xReauthPortIndexread-onlycurrentIEEE 802.1X Enabled Port Index.
1.3.6.1.4.1.8691.2.12.1.7.3.4.1.1.2Columndot1xReauthread-writecurrentReauth IEEE 802.1X.
1.3.6.1.4.1.8691.2.12.1.7.3.4.2Scalardot1XReauthActiveread-writecurrentSubmit dot1X Reauth setting.
1.3.6.1.4.1.8691.2.12.1.7.3.5NodeportAccessControlList
1.3.6.1.4.1.8691.2.12.1.7.3.5.1TableportAccessControlTablenot-accessiblecurrentThe Port Access Control table.
1.3.6.1.4.1.8691.2.12.1.7.3.5.1.1RowportAccessControlEntrynot-accessiblecurrentThe Port Access Control table entry.
1.3.6.1.4.1.8691.2.12.1.7.3.5.1.1.1ColumnportAccessControlAddressread-onlycurrentThe MAC address which is static locked or IEEE 802.1X authorized.
1.3.6.1.4.1.8691.2.12.1.7.3.5.1.1.2ColumnportAccessControlPortNoread-onlycurrentThe port number that the Port Access Control address resides.
1.3.6.1.4.1.8691.2.12.1.7.3.5.1.1.3ColumnportAccessControlAccessStatusread-onlycurrentThe access status of the Port Access Control address.
1.3.6.1.4.1.8691.2.12.1.7.3.5.1.1.4ColumnportAccessControlStatusread-createcurrentThe status is active to indicate normal. Use createAndGo to create new on multiple SET. Use createAndWait to create new on one SET all then actvie. Use destroy…
1.3.6.1.4.1.8691.2.12.1.7.3.6NodewarningList
1.3.6.1.4.1.8691.2.12.1.7.3.6.1TablewarningListTablenot-accessiblecurrentThe Port Access Control table.
1.3.6.1.4.1.8691.2.12.1.7.3.6.1.1RowwarningListEntrynot-accessiblecurrentThe Port Access Control table entry.
1.3.6.1.4.1.8691.2.12.1.7.3.6.1.1.1ColumnwarningListIndexread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.6.1.1.2ColumnwarningListEventread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.6.1.1.3ColumnwarningListRelayread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7NodeethernetMonitor
1.3.6.1.4.1.8691.2.12.1.7.3.7.1TableethernetMonitorTablenot-accessiblecurrentThe Port Access Control table.
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1RowethernetMonitorEntrynot-accessiblecurrentThe Port Access Control table entry.
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.1ColumnethernetMonitorTxTotalread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.2ColumnethernetMonitorTxUicastread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.3ColumnethernetMonitorTxMulticastread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.4ColumnethernetMonitorTxBroadcastread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.5ColumnethernetMonitorTxCollisionread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.6ColumnethernetMonitorRxTotalread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.7ColumnethernetMonitorRxUicastread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.8ColumnethernetMonitorRxMulticastread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.9ColumnethernetMonitorRxBroadcastread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.10ColumnethernetMonitorRxPauseread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.11ColumnethernetMonitorTxErrread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.12ColumnethernetMonitorTxErrLateread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.13ColumnethernetMonitorTxErrExcessiveread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.14ColumnethernetMonitorRxErrread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.15ColumnethernetMonitorRxErrCRCread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.16ColumnethernetMonitorRxErrDiscardread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.17ColumnethernetMonitorRxErrUndersizeread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.18ColumnethernetMonitorRxErrFragmentsread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.19ColumnethernetMonitorRxErrOversizeread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.1.1.20ColumnethernetMonitorRxErrJabberread-onlycurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.2ScalarethernetMonitorResetread-writecurrent
1.3.6.1.4.1.8691.2.12.1.7.3.7.3TablemonitorPortTablenot-accessiblecurrentThe port table of monitor function.
1.3.6.1.4.1.8691.2.12.1.7.3.7.3.1RowmonitorPortEntrynot-accessiblecurrentThe port table entry of monitor function.
1.3.6.1.4.1.8691.2.12.1.7.3.7.3.1.1ColumnmonitorLinkStatusread-onlycurrentThe port link status.
1.3.6.1.4.1.8691.2.12.1.7.3.7.3.1.2ColumnmonitorSpeedread-onlycurrentThe port speed and duplex status.
1.3.6.1.4.1.8691.2.12.1.7.3.7.3.1.3ColumnmonitorFDXFlowCtrlread-onlycurrentThe Full-Duplex flow control status
1.3.6.1.4.1.8691.2.12.1.7.3.7.3.1.4ColumnmonitorAutoMDIread-onlycurrentThe port MDI/MDIX status.
1.3.6.1.4.1.8691.2.12.1.7.3.7.3.1.5ColumnmonitorConnectedIPread-onlycurrentThe IP of connected device.
1.3.6.1.4.1.8691.2.12.1.7.3.7.3.1.6ColumnmonitorTrafficread-onlycurrentThe trafic loading percentage of port.
1.3.6.1.4.1.8691.2.12.1.7.3.8NodetrunkTableList
1.3.6.1.4.1.8691.2.12.1.7.3.8.1TabletrunkTablenot-accessiblecurrentPort Trunking Table.
1.3.6.1.4.1.8691.2.12.1.7.3.8.1.1RowtrunkEntrynot-accessiblecurrentPort Trunking Entry.
1.3.6.1.4.1.8691.2.12.1.7.3.8.1.1.1ColumntrunkIndexread-onlycurrentTrunking Group Index.
1.3.6.1.4.1.8691.2.12.1.7.3.8.1.1.2ColumntrunkPortread-onlycurrentTrunking Group Member Port.
1.3.6.1.4.1.8691.2.12.1.7.3.8.1.1.3ColumntrunkStatusread-onlycurrentTrunking Port Status.
1.3.6.1.4.1.8691.2.12.1.7.3.9NodevlanList
1.3.6.1.4.1.8691.2.12.1.7.3.9.1TablevlanTablenot-accessiblecurrentThe VLAN table.
1.3.6.1.4.1.8691.2.12.1.7.3.9.1.1RowvlanEntrynot-accessiblecurrentVLAN Entry.
1.3.6.1.4.1.8691.2.12.1.7.3.9.1.1.1ColumnvlanIdread-onlycurrentThe VLAN id.
1.3.6.1.4.1.8691.2.12.1.7.3.9.1.1.2ColumnjoinedAccessPortsread-onlycurrentThe access ports that joined this VID.
1.3.6.1.4.1.8691.2.12.1.7.3.9.1.1.3ColumnjoinedTrunkPortsread-onlycurrentThe trunk ports that joined this VID.
1.3.6.1.4.1.8691.2.12.1.7.3.10NodecommRedStatus
1.3.6.1.4.1.8691.2.12.1.7.3.10.1ScalaractiveProtocolOfRedundancyread-onlycurrentThis shows the active redundancy protocol of this server now. The none(0) stauts will be showed if only if the server's redundancy protocol is set to spanning …
1.3.6.1.4.1.8691.2.12.1.7.3.10.2NodespanningTreeStatus
1.3.6.1.4.1.8691.2.12.1.7.3.10.2.1ScalarspanningTreeRootread-onlycurrentThe root of spanning tree.
1.3.6.1.4.1.8691.2.12.1.7.3.10.2.2TablespanningTreeStatusTablenot-accessiblecurrentThe spanning tree table.
1.3.6.1.4.1.8691.2.12.1.7.3.10.2.2.1RowspanningTreeStatusEntrynot-accessiblecurrentThe spanning tree port entry.
1.3.6.1.4.1.8691.2.12.1.7.3.10.2.2.1.1ColumnspanningTreePortStatusread-onlycurrentThe port status of spanning tree protocol.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3NodeturboRingStatus
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.1ScalarturboRingMasterread-onlycurrentIs this a Master or Slave.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.2TableturboRingPortTablenot-accessiblecurrentTurbo Ring Port Table.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.2.1RowturboRingPortEntrynot-accessiblecurrentTurbo Ring Port Entry.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.2.1.1ColumnturboRingPortIndexread-onlycurrentTurbo Ring Port Index.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.2.1.2ColumnturboRingPortStatusread-onlycurrentTurbo Ring Port Status.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.2.1.3ColumnturboRingPortDesignatedBridgeread-onlymandatoryThe MAC address of the bridge which this port considers to be the Designated Bridge for this port's segment.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.2.1.4ColumnturboRingPortDesignatedPortread-onlymandatoryThe Port Number of the port on the Designated Bridge for this port's segment.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.3ScalarturboRingDesignatedMasterread-onlymandatoryThe MAC address of the bridge which is the Master of the TURBO RING.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.4ScalarturboRingCouplingPortStatusread-onlycurrentThe coupling port status of ring coupling function.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.5ScalarturboRingControlPortStatusread-onlycurrentThe control port status of ring coupling function.
1.3.6.1.4.1.8691.2.12.1.7.3.10.3.6ScalarturboRingBrokenStatusread-onlycurrentTurbo Ring broken display.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4NodeturboRingV2Status
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.1NodeturboRingV2Ring1Status
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.1.1ScalarmasterStatusRing1read-onlycurrentSet this to be Master.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.1.2ScalardesignatedMasterRing1read-onlymandatoryThe MAC address of the bridge which is the Master of the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.1.3Scalarrdnt1stPortStatusRing1read-onlycurrentThe status of 1st Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.1.4Scalarrdnt2ndPortStatusRing1read-onlycurrentThe status of 2nd Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.1.5ScalarbrokenStatusRing1read-onlycurrentturboRingV2 broken display.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.2NodeturboRingV2Ring2Status
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.2.1ScalarmasterStatusRing2read-onlycurrentSet this to be Master.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.2.2ScalardesignatedMasterRing2read-onlymandatoryThe MAC address of the bridge which is the Master of the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.2.3Scalarrdnt1stPortStatusRing2read-onlycurrentThe status of 1st Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.2.4Scalarrdnt2ndPortStatusRing2read-onlycurrentThe status of 2nd Redundant Port on the turboRingV2.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.2.5ScalarbrokenStatusRing2read-onlycurrentturboRingV2 broken display.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.3NodeturboRingV2CouplingStatus
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.3.1Scalarcoupling1stPortStatusread-onlycurrentThe 1st coupling port status of coupling function.
1.3.6.1.4.1.8691.2.12.1.7.3.10.4.3.2Scalarcoupling2ndPortStatusread-onlycurrentThe 2nd coupling port status of coupling function.
1.3.6.1.4.1.8691.2.12.1.7.3.10.5NodeturboChainStatus
1.3.6.1.4.1.8691.2.12.1.7.3.10.5.1ScalarturboChainPort1Statusread-onlycurrentTurbo Chain Port 1 Status
1.3.6.1.4.1.8691.2.12.1.7.3.10.5.2ScalarturboChainPort2Statusread-onlycurrentTurbo Chain Port 2 Status
1.3.6.1.4.1.8691.2.12.1.7.3.10.5.3ScalarturboChainPort1PartnerBridgeread-onlymandatoryThe MAC address of the bridge which is attatched to this device's Turbo Chain Port 1.
1.3.6.1.4.1.8691.2.12.1.7.3.10.5.4ScalarturboChainPort2PartnerBridgeread-onlymandatoryThe MAC address of the bridge which is attatched to this device's Turbo Chain Port 2.
1.3.6.1.4.1.8691.2.12.1.8Noderestart
1.3.6.1.4.1.8691.2.12.1.8.1ScalarrestartSystemread-writecurrentRestart the NPort S8000 series device server. Be sure to save all of your configuration changes before you restart the system. Otherwise, all of the changes wi…
1.3.6.1.4.1.8691.2.12.1.8.2ScalarrestartPortNumberread-writecurrentRestart serial port. Restarting will cause port reseting.
Type Definitions
NameSyntaxStatusDescription
PortListOCTET STRINGcurrentEach octet within this value specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents…