MSERIES-TC
8 objects
This is the enterprise specific TC MIB for SmartOptics M-Series
Imported Objects
| MSERIES-MIB | mseries |
| SNMPv2-SMI | MODULE-IDENTITY |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.30826.1.5 | IdentitysmartTcMIB | This is the enterprise specific TC MIB for SmartOptics M-Series |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AlarmNotificationType | INTEGER { undefined (0), other (1), communicationsAlarm (2), qualityOfServiceAlarm (3), processingErrorAlarm (4), equipmentAlarm (5), environmental (6), integrityViolation (7), operationalViolation (8), physicalViolation(9), securityServiceOrMechanismViloation (10), timeDomainViolation (11) } | current | Type of alarm as defined in ITU-T X.733. |
| AlarmPerceivedSeverity | INTEGER { cleared (1), indeterminate (2), critical (3), major (4), minor (5), warning (6) } | current | Alarm severity as defined in ITU-T X.733. |
| AlarmProbableCause | INTEGER { undefined (0), adapterError (1), applicationSubsystemFailure (2), bandwidthReduced (3), callEstablishmentError (4), communicationsProtocolError (5), communicationsSubsystemFailure (6), configurationOrCustomizationError (7), congestion (8), corruptData (9), cpuCyclesLimitExceeded (10), dTEdCEInterfaceError (11), datasetOrModemError (12), degradedSignal (13), enclosureDoorOpen (14), equipmentMalfunction (15), excessiveVibration (16), fileError (17), fireDetected (18), floodDetected (19), framingError (20), heatingOrVentilationOrCoolingSystemProblem (21), humidityUnacceptable (22), inputDeviceError (23), inputOutputDeviceError (24), lANError (25), leakDetected (26), localNodeTransmissionError (27), lossOfFrame (28), lossOfSignal (29), materialSupplyExhausted (30), multiplexerProblem (31), outOfMemory (32), outputDeviceError (33), performanceDegraded (34), powerProblem (35), pressureUnacceptable (36), processorProblem (37), pumpFailure (38), queueSizeExceeded (39), receiveFailure (40), receiverFailure (41), remoteNodeTransmissionError (42), resourceAtOrNearingCapacity (43), responseTimeExcessive (44), retransmissionRateExcessive (45), softwareProgramError (46), softwareError (47), softwareProgramAbnormallyTerminated (48), storageCapacityProblem (49), temperatureUnacceptable (50), thresholdCrossed (51), timingProblem (52), toxicLeakDetected (53), transmitFailure (54), transmitterFailure (55), underlyingResourceUnavailable (56), versionMismatch (57) } | current | Alarm probable cause as defined in ITU-T X.733. |
| PortMode | INTEGER { normal (1), service (2) } | current | Port Mode. normal - The port is active. Alarms are not suppressed. service - the port is in Service Mode. Alarms are beeing suppressed. When service is ready the Port Mode should be set back to normal. |
| PortStatus | INTEGER { idle (1), down (2), up (3), high (4), low (5), eyeSafety (6), cd (7), ncd (8) } | current | The operational state for a port. idle - The port is not activated down - The port traffic is lost. up - There is traffic on the port. high - The port got to high power. low - The port got to low power. eyeSafety - The … |
| PortType | INTEGER { rx (1), tx (2), biDi (3) } | current | Port direction. rx - The port direction is receiving(Rx). tx - The port direction is transmitting(Tx). biDi - The port direction is both transmitting and receiving. |
| UnitType | INTEGER { nmb (1), psu1 (2), psu2 (3), fan (4), system (5), slaveNmb (6), slavePsu1 (7), slavePsu2 (8), slaveFan (9) } | current | The unit type in the M-Series. nmb - Network Management Board. The controlling board of the M-Series. psu1 - The Power Supply in slot 1 of the M-Series. psu2 - The Power Supply in slot 2 of the M-Series. fan - The Fan o… |