NBS-ODSYS-MIB
96 objects
For managing Opti-Driver systems.
Imported Objects
| IF-MIB | InterfaceIndex |
| NBS-MIB | nbs NbsTcMilliAmp NbsTcMilliVolt NbsTcPartIndex NbsTcStatusLevel NbsTcStatusSimple NbsTcTemperature |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.629.228 | IdentitynbsOdsysMib | For managing Opti-Driver systems. | ||
| 1.3.6.1.4.1.629.228.2 | IdentitynbsOdsysChasGrp | current | Chassis component overview | |
| 1.3.6.1.4.1.629.228.2.1 | TablenbsOdsysChasTable | not-accessible | current | |
| 1.3.6.1.4.1.629.228.2.1.1 | RownbsOdsysChasEntry | not-accessible | current | Information about a particular OptiDriver chassis. |
| 1.3.6.1.4.1.629.228.2.1.1.1 | ColumnnbsOdsysChasIndex | read-only | current | The nbsCmmcChassisIndex of this chassis |
| 1.3.6.1.4.1.629.228.2.1.1.10 | ColumnnbsOdsysChasCcMaxCount | read-only | current | The maximum number of control cards that can be installed in this chassis |
| 1.3.6.1.4.1.629.228.2.1.1.20 | ColumnnbsOdsysChasPsMaxCount | read-only | current | The number of power supply bays/slots in this chassis |
| 1.3.6.1.4.1.629.228.2.1.1.30 | ColumnnbsOdsysChasFtMaxCount | read-only | current | The number of fan tray bays/slots in this chassis |
| 1.3.6.1.4.1.629.228.3 | IdentitynbsOdsysCcGrp | current | Chassis control card information | |
| 1.3.6.1.4.1.629.228.3.1 | TablenbsOdsysCcTable | not-accessible | current | Information about OptiDriver chassis control/fpga cards |
| 1.3.6.1.4.1.629.228.3.1.1 | RownbsOdsysCcEntry | not-accessible | current | Status information for a particular control card slot/bay. When a control card is present, it will also have entries in nbsPartHardTable, nbsPartFirmTable, and… |
| 1.3.6.1.4.1.629.228.3.1.1.1 | ColumnnbsOdsysCcChasIndex | read-only | current | The nbsCmmcChassisIndex of this control card's chassis |
| 1.3.6.1.4.1.629.228.3.1.1.2 | ColumnnbsOdsysCcBayIndex | read-only | current | The control card slot/bay # |
| 1.3.6.1.4.1.629.228.3.1.1.10 | ColumnnbsOdsysCcChIfIndex | read-only | current | The nbsPartHardIfIndex of this Cc daughtercard's chassis |
| 1.3.6.1.4.1.629.228.3.1.1.11 | ColumnnbsOdsysCcPartIndex | read-only | current | The nbsPartHardPartIndex of this Cc daughtercard |
| 1.3.6.1.4.1.629.228.3.1.1.30 | ColumnnbsOdsysCcThermActual | read-only | current | Indicates the current temperature reading, in degrees celsius |
| 1.3.6.1.4.1.629.228.3.1.1.40 | ColumnnbsOdsysCcThermLevel | read-only | current | Indicates level of current temperature reading with respect to the CcTherm threshold objects below |
| 1.3.6.1.4.1.629.228.3.1.1.41 | ColumnnbsOdsysCcThermThreshLoErr | read-only | current | Indicates the minimum functional operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.3.1.1.42 | ColumnnbsOdsysCcThermThreshLoWarn | read-only | current | Indicates the minimum safe operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.3.1.1.43 | ColumnnbsOdsysCcThermThreshHiWarn | read-only | current | Indicates the maximum safe operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.3.1.1.44 | ColumnnbsOdsysCcThermThreshHiErr | read-only | current | Indicates the maximum functional operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.3.1.1.50 | ColumnnbsOdsysCcOperationalStatus | read-only | current | Operational status of this daughtercard |
| 1.3.6.1.4.1.629.228.4 | IdentitynbsOdsysFtGrp | current | Chassis cooling system | |
| 1.3.6.1.4.1.629.228.4.1 | TablenbsOdsysFtTable | not-accessible | current | |
| 1.3.6.1.4.1.629.228.4.1.1 | RownbsOdsysFtEntry | not-accessible | current | A particular chassis cooling assembly slot/bay. Each installed fan tray also has entries in nbsPartHardTable. The events nbsCmmcTrapFanFailure, nbsCmmcTrapFanR… |
| 1.3.6.1.4.1.629.228.4.1.1.1 | ColumnnbsOdsysFtChasIndex | read-only | current | nbsCmmcChassisIndex of this fan tray's chassis |
| 1.3.6.1.4.1.629.228.4.1.1.2 | ColumnnbsOdsysFtBayIndex | read-only | current | Fan tray bay/slot number, unique within this chassis |
| 1.3.6.1.4.1.629.228.4.1.1.3 | ColumnnbsOdsysFtOperationalStatus | read-only | current | The value notSupported(1) indicates the fan tray is absent. |
| 1.3.6.1.4.1.629.228.4.1.1.10 | ColumnnbsOdsysFtChIfIndex | read-only | current | The nbsPartHardIfIndex of this fan tray's chassis |
| 1.3.6.1.4.1.629.228.4.1.1.11 | ColumnnbsOdsysFtPartIndex | read-only | current | The nbsPartHardPartIndex of this fan tray |
| 1.3.6.1.4.1.629.228.4.1.1.20 | ColumnnbsOdsysFtFanCount | read-only | current | The number of fans in this tray |
| 1.3.6.1.4.1.629.228.4.1.1.30 | ColumnnbsOdsysFtThermActual | read-only | current | Indicates the current temperature reading, in degrees celsius |
| 1.3.6.1.4.1.629.228.4.1.1.40 | ColumnnbsOdsysFtThermLevel | read-only | current | Indicates level of current temperature reading with respect to the FtTherm threshold objects below |
| 1.3.6.1.4.1.629.228.4.1.1.41 | ColumnnbsOdsysFtThermThreshLoErr | read-only | current | Indicates the minimum functional operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.4.1.1.42 | ColumnnbsOdsysFtThermThreshLoWarn | read-only | current | Indicates the minimum safe operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.4.1.1.43 | ColumnnbsOdsysFtThermThreshHiWarn | read-only | current | Indicates the maximum safe operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.4.1.1.44 | ColumnnbsOdsysFtThermThreshHiErr | read-only | current | Indicates the maximum functional operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.5 | IdentitynbsOdsysPsGrp | current | Chassis power supplies | |
| 1.3.6.1.4.1.629.228.5.2 | TablenbsOdsysPsTable | not-accessible | current | Information about OptiDriver chassis' power supplies |
| 1.3.6.1.4.1.629.228.5.2.1 | RownbsOdsysPsEntry | not-accessible | current | A particular power supply slot/bay. Each installed power supply also has entries in nbsPartHardTable. The events nbsCmmcTrapPowerSupplyFailure, nbsCmmcTrapPowe… |
| 1.3.6.1.4.1.629.228.5.2.1.1 | ColumnnbsOdsysPsChasIndex | read-only | current | The nbsCmmcChassisIndex of this power supply's chassis |
| 1.3.6.1.4.1.629.228.5.2.1.2 | ColumnnbsOdsysPsBayIndex | read-only | current | Number of this power supply slot/bay |
| 1.3.6.1.4.1.629.228.5.2.1.3 | ColumnnbsOdsysPsOperationalStatus | read-only | current | The value notSupported(1) indicates power supply is absent. |
| 1.3.6.1.4.1.629.228.5.2.1.10 | ColumnnbsOdsysPsChIfIndex | read-only | current | The nbsPartHardIfIndex of this power supply's chassis |
| 1.3.6.1.4.1.629.228.5.2.1.11 | ColumnnbsOdsysPsPartIndex | read-only | current | The nbsPartHardPartIndex of this power supply |
| 1.3.6.1.4.1.629.228.5.2.1.30 | ColumnnbsOdsysPsFanCount | read-only | current | Indicates how many internal fans this power supply has. |
| 1.3.6.1.4.1.629.228.5.2.1.40 | ColumnnbsOdsysPsThermActual | read-only | current | Indicates the current temperature reading, in degrees celsius |
| 1.3.6.1.4.1.629.228.5.2.1.41 | ColumnnbsOdsysPsThermLevel | read-only | current | Indicates level of current temperature reading with respect to the PsTherm threshold objects below |
| 1.3.6.1.4.1.629.228.5.2.1.42 | ColumnnbsOdsysPsThermThreshLoErr | read-only | current | Indicates the minimum functional operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.5.2.1.43 | ColumnnbsOdsysPsThermThreshLoWarn | read-only | current | Indicates the minimum safe operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.5.2.1.44 | ColumnnbsOdsysPsThermThreshHiWarn | read-only | current | Indicates the maximum safe operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.5.2.1.45 | ColumnnbsOdsysPsThermThreshHiErr | read-only | current | Indicates the maximum functional operating temperature, in degrees celsius |
| 1.3.6.1.4.1.629.228.5.2.1.50 | ColumnnbsOdsysPsVInActual | read-only | current | Indicates the input voltage reading, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.51 | ColumnnbsOdsysPsVInLevel | read-only | current | Indicates level of input voltage reading with respect to the PsVIn threshold objects below |
| 1.3.6.1.4.1.629.228.5.2.1.52 | ColumnnbsOdsysPsVInThreshLoErr | read-only | current | Indicates the minimum functional input voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.53 | ColumnnbsOdsysPsVInThreshLoWarn | read-only | current | Indicates the minimum safe input voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.54 | ColumnnbsOdsysPsVInThreshHiWarn | read-only | current | Indicates the maximum safe input voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.55 | ColumnnbsOdsysPsVInThreshHiErr | read-only | current | Indicates the maximum functional input voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.60 | ColumnnbsOdsysPsVOutActual | read-only | current | Indicates the output voltage reading, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.61 | ColumnnbsOdsysPsVOutLevel | read-only | current | Indicates level of output voltage reading with respect to the PsVOut threshold objects below |
| 1.3.6.1.4.1.629.228.5.2.1.62 | ColumnnbsOdsysPsVOutThreshLoErr | read-only | current | Indicates the minimum functional output voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.63 | ColumnnbsOdsysPsVOutThreshLoWarn | read-only | current | Indicates the minimum safe output voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.64 | ColumnnbsOdsysPsVOutThreshHiWarn | read-only | current | Indicates the maximum safe output voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.65 | ColumnnbsOdsysPsVOutThreshHiErr | read-only | current | Indicates the maximum functional output voltage, in millivolts |
| 1.3.6.1.4.1.629.228.5.2.1.70 | ColumnnbsOdsysPsIInActual | read-only | current | Indicates the input current reading, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.71 | ColumnnbsOdsysPsIInLevel | read-only | current | Indicates level of input current reading with respect to the PsIIn threshold objects below |
| 1.3.6.1.4.1.629.228.5.2.1.72 | ColumnnbsOdsysPsIInThreshLoErr | read-only | current | Indicates the minimum functional input current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.73 | ColumnnbsOdsysPsIInThreshLoWarn | read-only | current | Indicates the minimum safe input current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.74 | ColumnnbsOdsysPsIInThreshHiWarn | read-only | current | Indicates the maximum safe input current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.75 | ColumnnbsOdsysPsIInThreshHiErr | read-only | current | Indicates the maximum functional input current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.80 | ColumnnbsOdsysPsIOutActual | read-only | current | Indicates the output current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.81 | ColumnnbsOdsysPsIOutLevel | read-only | current | Indicates level of output current reading with respect to the PsIOut threshold objects below |
| 1.3.6.1.4.1.629.228.5.2.1.82 | ColumnnbsOdsysPsIOutThreshLoErr | read-only | current | Indicates the minimum functional output current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.83 | ColumnnbsOdsysPsIOutThreshLoWarn | read-only | current | Indicates the minimum safe output current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.84 | ColumnnbsOdsysPsIOutThreshHiWarn | read-only | current | Indicates the maximum safe output current, in milliamps |
| 1.3.6.1.4.1.629.228.5.2.1.85 | ColumnnbsOdsysPsIOutThreshHiErr | read-only | current | Indicates the maximum functional output current, in milliamps |
| 1.3.6.1.4.1.629.228.100 | IdentitynbsOdsysEventsGrp | current | ||
| 1.3.6.1.4.1.629.228.100.0 | IdentitynbsOdsysEvents | current | Event NOTIFICATIONS | |
| 1.3.6.1.4.1.629.228.100.0.30 | NotificationnbsOdsysTrapCcThermLevelBad | current | Sent when nbsOdsysCcThermLevel changes to anything but statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.31 | NotificationnbsOdsysTrapCcThermLevelOk | current | Sent when nbsOdsysCcThermLevel changes to statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.40 | NotificationnbsOdsysTrapFtThermLevelBad | current | Sent when fan tray's nbsOdsysFtThermLevel changes to anything but statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.41 | NotificationnbsOdsysTrapFtThermLevelOk | current | Sent when fan tray's nbsOdsysFtThermLevel changes to statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.50 | NotificationnbsOdsysTrapPsThermLevelBad | current | Sent when power supply's nbsOdsysPsThermLevel changes to anything but statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.51 | NotificationnbsOdsysTrapPsThermLevelOk | current | Sent when power supply's nbsOdsysPsThermLevel changes to statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.60 | NotificationnbsOdsysTrapPsVInLevelBad | current | Sent when power supply's nbsOdsysPsVInLevel changes to anything but statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.61 | NotificationnbsOdsysTrapPsVInLevelOk | current | Sent when power supply's nbsOdsysPsVInLevel changes to statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.70 | NotificationnbsOdsysTrapPsVOutLevelBad | current | Sent when power supply's nbsOdsysPsVOutLevel changes to anything but statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.71 | NotificationnbsOdsysTrapPsVOutLevelOk | current | Sent when power supply's nbsOdsysPsVOutLevel changes to statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.80 | NotificationnbsOdsysTrapPsIInLevelBad | current | Sent when power supply's nbsOdsysPsIInLevel changes to anything but statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.81 | NotificationnbsOdsysTrapPsIInLevelOk | current | Sent when power supply's nbsOdsysPsIInLevel changes to statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.90 | NotificationnbsOdsysTrapPsIOutLevelBad | current | Sent when power supply's nbsOdsysPsIOutLevel changes to anything but statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.91 | NotificationnbsOdsysTrapPsIOutLevelOk | current | Sent when power supply's nbsOdsysPsIOutLevel changes to statusGood (4) | |
| 1.3.6.1.4.1.629.228.100.0.131 | NotificationnbsOdsysTrapCcFailed | current | Triggered when nbsOdsysCcOperationalStatus transitions to bad (2) | |
| 1.3.6.1.4.1.629.228.100.0.132 | NotificationnbsOdsysTrapCcRestored | current | Triggered when nbsOdsysCcOperationalStatus transitions to good (3) | |
| 1.3.6.1.4.1.629.228.100.0.133 | NotificationnbsOdsysTrapCcRemoved | current | Triggered when control card is removed from chassis | |
| 1.3.6.1.4.1.629.228.100.0.134 | NotificationnbsOdsysTrapCcInserted | current | Triggered when control card is inserted into chassis |