NBS-SFF-MIB
126 objects
MIB for representing SFF MSA standards
Imported Objects
| IF-MIB | InterfaceIndex |
| NBS-CMMCENUM-MIB | NbsCmmcChannelBand |
| NBS-MIB | nbs NbsTcMHz |
| SNMPv2-SMI | MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.629.204 | IdentitynbsSffMib | MIB for representing SFF MSA standards | ||
| 1.3.6.1.4.1.629.204.1 | IdentitynbsSffObjects | current | all MIB objects in nbsSFF MIB. | |
| 1.3.6.1.4.1.629.204.1.1 | IdentitynbsSffMsaGrp | current | All SFF MSA objects. | |
| 1.3.6.1.4.1.629.204.1.1.1 | TablenbsSffMsaTable | not-accessible | current | Operations, Administration, and Management information |
| 1.3.6.1.4.1.629.204.1.1.1.1 | RownbsSffMsaEntry | not-accessible | current | Represents a SFF MSA details of a port. |
| 1.3.6.1.4.1.629.204.1.1.1.1.1 | ColumnnbsSffMsaPhysicalIfIndex | not-accessible | current | ifIndex from MIB2 |
| 1.3.6.1.4.1.629.204.1.1.1.1.2 | ColumnnbsSffMsaIdentifier | read-only | current | The MSA Identifier as reported in the MSA memory map, +1. Some of these MSA Identifiers are also represented in nbsCmmcPortType from the NBS-CMMC-MIB: nbsSffMs… |
| 1.3.6.1.4.1.629.204.1.1.1.1.3 | ColumnnbsSffMsaExtIdentifier | read-only | current | The field should be set to 04h for all SFP modules indicating serial ID module definition. Not supported value: 0 |
| 1.3.6.1.4.1.629.204.1.1.1.1.4 | ColumnnbsSffMsaOpticalConnector | read-only | current | The Optical Connector as reported in the MSA memory map, +1. Here is the list of values: 1 - unknown 2 - SC 3 - Fiber Channel Style 1 copper connector 4 - Fibe… |
| 1.3.6.1.4.1.629.204.1.1.1.1.5 | ColumnnbsSffMsaTransceiverCodes | read-only | current | The following bit significant indicators define the electronic or optical interfaces that are supported by the SFP transceiver. At least one bit shall be set i… |
| 1.3.6.1.4.1.629.204.1.1.1.1.6 | ColumnnbsSffMsaSerialEncoding | read-only | current | The encoding value indicates the serial encoding mechanism that is the nominal design target of the particular transceiver. The value shall be contained in the… |
| 1.3.6.1.4.1.629.204.1.1.1.1.7 | ColumnnbsSffMsaNominalBitRate | read-only | current | The nominal bit rate (BR, nominal) is specified in units of 100 Megabits per second, rounded off to the nearest 100 Megabits per second. The bit rate includes … |
| 1.3.6.1.4.1.629.204.1.1.1.1.8 | ColumnnbsSffMsaLinkLengthSmfKm | read-only | current | This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber. … |
| 1.3.6.1.4.1.629.204.1.1.1.1.9 | ColumnnbsSffMsaLinkLengthSmf100m | read-only | current | This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber. … |
| 1.3.6.1.4.1.629.204.1.1.1.1.10 | ColumnnbsSffMsaLinkLengthMmf10m | read-only | current | This value specifies link length that is supported by the transceiver while operating in compliance with applicable standards using 50 micron multimode OM2 [50… |
| 1.3.6.1.4.1.629.204.1.1.1.1.11 | ColumnnbsSffMsaLinkLength625Mmf10m | read-only | current | This value specifies link length that is supported by the transceiver while operating in compliance with applicable standards using 62.5 micron multimode OM1 [… |
| 1.3.6.1.4.1.629.204.1.1.1.1.12 | ColumnnbsSffMsaCopperLinkLength | read-only | current | This value specifies the minimum link length that is supported by the transceiver while operating in compliance with the applicable standards using copper cabl… |
| 1.3.6.1.4.1.629.204.1.1.1.1.13 | ColumnnbsSffMsaVendorName | read-only | current | The vendor name is a 16 character field that contains ASCII characters, The vendor name shall be the full name of the corporation, a commonly accepted abbrevia… |
| 1.3.6.1.4.1.629.204.1.1.1.1.14 | ColumnnbsSffMsaVendorOUI | read-only | current | The vendor organizationally unique identifier field (vendor OUI) is a 3-byte field that contains the IEEE Company Identifier for the vendor. A value of all zer… |
| 1.3.6.1.4.1.629.204.1.1.1.1.15 | ColumnnbsSffMsaVendorPartNumber | read-only | current | The vendor part number (vendor PN) is a 16-byte field that contains ASCII characters, left-aligned, defining the vendor part number or product name. Unlike the… |
| 1.3.6.1.4.1.629.204.1.1.1.1.16 | ColumnnbsSffMsaVendorRevision | read-only | current | The vendor revision number (vendor rev) is a 4-byte field that contains ASCII characters, defining the vendor's product revision number. Unlike the MSA standar… |
| 1.3.6.1.4.1.629.204.1.1.1.1.17 | ColumnnbsSffMsaBaseChecksumMatch | read-only | current | The check code is a one byte code that can be used to verify that the first 64 (0-63) bytes of serial information in the SFP transceiver is valid.Returns yes i… |
| 1.3.6.1.4.1.629.204.1.1.1.1.18 | ColumnnbsSffMsaLossOfSignalImplemented | read-only | current | Byte 65 Bit 1. Signal as defined in the specification |
| 1.3.6.1.4.1.629.204.1.1.1.1.19 | ColumnnbsSffMsaLossOfSignalInverted | read-only | current | Byte 65 Bit 2. Signal as defined in the specification |
| 1.3.6.1.4.1.629.204.1.1.1.1.20 | ColumnnbsSffMsaTxFault | read-only | current | Byte 65 Bit 3.TX_FAULT signal implemented. Reset definition in Section III and Laser Fault condition, Generated by laser safety system. |
| 1.3.6.1.4.1.629.204.1.1.1.1.21 | ColumnnbsSffMsaTxDisable | read-only | current | Byte 65 Bit 4.TX_DISABLE is implemented and disables the serial output. |
| 1.3.6.1.4.1.629.204.1.1.1.1.22 | ColumnnbsSffMsaRateSelectImplemented | read-only | current | Byte 65 Bit 5.If this bit is set then active control of the rate select pin is required to change rates. If bit is not set, no control of pin is required. In a… |
| 1.3.6.1.4.1.629.204.1.1.1.1.23 | ColumnnbsSffMsaMaxBitRate | read-only | current | The upper bit rate limit at which the SFP transceiver will still meet its specifications (BR, max) is specified in units of 1% above the nominal bit rate. A va… |
| 1.3.6.1.4.1.629.204.1.1.1.1.24 | ColumnnbsSffMsaMinBitRate | read-only | current | The lower bit rate limit at which the SFP transceiver will still meet its specifications (BR, min) is specified in units of 1% below the nominal bit rate. A va… |
| 1.3.6.1.4.1.629.204.1.1.1.1.25 | ColumnnbsSffMsaVendorSerialNumber | read-only | current | The vendor serial number (vendor SN) is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defi… |
| 1.3.6.1.4.1.629.204.1.1.1.1.26 | ColumnnbsSffMsaVendorDateCode | read-only | current | The date code is an 8-byte field that contains the vendor's date code in ASCII characters. The date code is mandatory. |
| 1.3.6.1.4.1.629.204.1.1.1.1.27 | ColumnnbsSffMsaExtChecksumMatch | read-only | current | The check code is a one byte code that can be used to verify that the first 32 bytes of extended serial information in the SFP transceiver is valid. The check … |
| 1.3.6.1.4.1.629.204.1.2 | IdentitynbsSffWdmGrp | current | All DWDM MSA objects. | |
| 1.3.6.1.4.1.629.204.1.2.1 | TablenbsSffWdmTable | not-accessible | current | Operations, Administration, and Management information |
| 1.3.6.1.4.1.629.204.1.2.1.1 | RownbsSffWdmEntry | not-accessible | current | Represents WDM properties of a port. |
| 1.3.6.1.4.1.629.204.1.2.1.1.1 | ColumnnbsSffWdmClassOfPower | read-only | current | Extended identifier of class of Power. |
| 1.3.6.1.4.1.629.204.1.2.1.1.2 | ColumnnbsSffWdmClassOfTemperature | read-only | current | Extended identifier of class of Temperature. class0 - Temperature in [-5, 70C] class1 - Temperature in [-40, 85C] class2 - reserved class3 - defined by MIB obj… |
| 1.3.6.1.4.1.629.204.1.2.1.1.3 | ColumnnbsSffWdmClassOfWdm | read-only | current | Extended identifier of class of WDM. 1 - No WDM 2 - CWDM 3 - DWDM 4 - Reserved |
| 1.3.6.1.4.1.629.204.1.2.1.1.4 | ColumnnbsSffWdmOpticalReach | read-only | current | This value specifies the link length in kilometers that is supported by the transceiver while operating in compliance with the applicable standards using singl… |
| 1.3.6.1.4.1.629.204.1.2.1.1.5 | ColumnnbsSffWdmMaxCaseTemperature | read-only | current | This field defines the maximum operating case temperature in Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs, this value is in byte 190. |
| 1.3.6.1.4.1.629.204.1.2.1.1.6 | ColumnnbsSffWdmMinCaseTemperature | read-only | current | This field defines the minimum operating case temperature in Celsius. |
| 1.3.6.1.4.1.629.204.1.2.1.1.7 | ColumnnbsSffWdmMaxSupplyCurrent | read-only | current | This field defines the maximum supply current, in milli Amps, which the module will consume under worst case conditions. |
| 1.3.6.1.4.1.629.204.1.2.1.1.8 | ColumnnbsSffWdmNumberOfChannels | read-only | current | This specifies the tuning range from 1 to 63, where 1 indicates this module is not tunable by user commands. |
| 1.3.6.1.4.1.629.204.1.2.1.1.9 | ColumnnbsSffWdmChannelSpacing | read-only | current | This field identifies the densest channel spacing the module is compatible with and the number of channels over which the module may be tuned by user command. |
| 1.3.6.1.4.1.629.204.1.2.1.1.10 | ColumnnbsSffWdmVariableDecisionThreshold | read-only | current | DWDM Variable Decission Threshold. |
| 1.3.6.1.4.1.629.204.1.2.1.1.11 | ColumnnbsSffWdmWavelengthMonitorType | read-only | current | DWDM Wavelength monitor type in A2 byte. |
| 1.3.6.1.4.1.629.204.1.2.1.1.12 | ColumnnbsSffWdmExtTransmitPowerType | read-only | current | DWDM Extended Transmit Power Type. |
| 1.3.6.1.4.1.629.204.1.2.1.1.13 | ColumnnbsSffWdmVariableOpticalAttenuator | read-only | current | DWDM Variable Optical Atttenuator. |
| 1.3.6.1.4.1.629.204.1.2.1.1.14 | ColumnnbsSffWdmPilotToneFunctionality | read-only | current | DWDM Pilot Tone Functionality. |
| 1.3.6.1.4.1.629.204.1.2.1.1.15 | ColumnnbsSffWdmOptionalInterruptPin | read-only | current | DWDM Optional Interrupt Pin. |
| 1.3.6.1.4.1.629.204.1.2.1.1.16 | ColumnnbsSffWdmLaserWavelength | read-only | current | Nominal transmitter output wavelength. For SFPs, per Specification for DWDM SFP Transceiver, section 2.2.1, The laser wavelength is equal to the 16 bit integer… |
| 1.3.6.1.4.1.629.204.1.2.1.1.17 | ColumnnbsSffWdmFrequency | read-only | current | Nominal transmitter frequency, in MHz |
| 1.3.6.1.4.1.629.204.1.2.1.1.18 | ColumnnbsSffWdmChannelBand | read-only | current | ITU Channel Band |
| 1.3.6.1.4.1.629.204.1.2.1.1.19 | ColumnnbsSffWdmChannelNumber | read-only | current | ITU Channel Number |
| 1.3.6.1.4.1.629.204.1.3 | IdentitynbsSffDiagnosticsGrp | current | All Diagnostics objects. | |
| 1.3.6.1.4.1.629.204.1.3.1 | TablenbsSffDiagsTable | not-accessible | current | Operations, Administration, and Management information |
| 1.3.6.1.4.1.629.204.1.3.1.1 | RownbsSffDiagsEntry | not-accessible | current | Represents Digital Diagnostics of a port. |
| 1.3.6.1.4.1.629.204.1.3.1.1.1 | ColumnnbsSffDiagsRateIdentifier | read-only | current | The rate identifier byte refers to several (optional) industry standard definitions of Rate_Select or Application_Select control behaviors, intended to manage … |
| 1.3.6.1.4.1.629.204.1.3.1.1.2 | ColumnnbsSffDiagsLinkLengthOm3 | read-only | current | This value specifies link length that is supported by the transceiver while operating in compliance with applicable standards using 50 micron multimode OM3 [20… |
| 1.3.6.1.4.1.629.204.1.3.1.1.3 | ColumnnbsSffDiagsLaserWavelength | read-only | current | Nominal transmitter output wavelength at room temperature. 16 bit value with byte 60 as high order byte and byte 61 as low order byte. The laser wavelength is … |
| 1.3.6.1.4.1.629.204.1.3.1.1.4 | ColumnnbsSffDiagsLROutputImplemented | read-only | current | Byte 64, bit 0. Value of 1 identifies a conventional limiting (or unspecified) receiver output. Value of 2 identifies a linear receiver output. |
| 1.3.6.1.4.1.629.204.1.3.1.1.5 | ColumnnbsSffDiagsPowerLevelDeclaration | read-only | current | Byte 64, bit 1. Value 1 identifies Power Level 1 (or unspecified) requirements. Value 2 identifies a Power Level2 requirements. |
| 1.3.6.1.4.1.629.204.1.3.1.1.6 | ColumnnbsSffDiagsCooledTranDeclaration | read-only | current | Byte 64, bit 2. Value 1 identifies a conventional uncooled (or unspecified) laser implementation. Value 2 identifies a cooled laser transmitter implementation. |
| 1.3.6.1.4.1.629.204.1.3.1.1.7 | ColumnnbsSffDiagsAddressChangeRequired | read-only | current | Byte 92, bit 2 indicates whether or not it is necessary for the host to perform an address change sequence before accessing information at 2-wire serial addres… |
| 1.3.6.1.4.1.629.204.1.3.1.1.8 | ColumnnbsSffDiagsPowerMeasurementType | read-only | current | Byte 92, bit 3 indicates whether the received power measurement represents average input optical power or OMA. If the bit is set, average power is monitored. I… |
| 1.3.6.1.4.1.629.204.1.3.1.1.9 | ColumnnbsSffDiagsExternallyCalibrated | read-only | current | Byte 92, bit 4 Externally Calibrated Two calibration options are possible if bit 6 has been set indicating that digital diagnostic monitoring has been implemen… |
| 1.3.6.1.4.1.629.204.1.3.1.1.10 | ColumnnbsSffDiagsInternallyCalibrated | read-only | current | Byte 92, bit 5 Internally Calibrated. Two calibration options are possible if bit 6 has been set indicating that digital diagnostic monitoring has been impleme… |
| 1.3.6.1.4.1.629.204.1.3.1.1.11 | ColumnnbsSffDiagsDDMonitoringImplemented | read-only | current | Byte 92, bit 6. If this bit is set indicating that digital diagnostic monitoring has been implemented, received power monitoring, transmitted power monitoring,… |
| 1.3.6.1.4.1.629.204.1.3.1.1.12 | ColumnnbsSffDiagsOptRateSelectControl | read-only | current | Byte 93 bit 1. Optional Rate Select control implemented per SFF-8431. Sets to 1 if not implemented, 2 if implemented. |
| 1.3.6.1.4.1.629.204.1.3.1.1.13 | ColumnnbsSffDiagsOptAppSelectControl | read-only | current | Based on byte 93 bit 2. Optional Application Select control implemented per SFF-8079. Sets to 1 if not implemented, 2 if implemented. |
| 1.3.6.1.4.1.629.204.1.3.1.1.14 | ColumnnbsSffDiagsOptSoftRSControlMon | read-only | current | Based on byte 93 bit 3. Optional soft RATE_SELECT control and monitoring implemented. Sets to 1 if not implemented, 2 if implemented. |
| 1.3.6.1.4.1.629.204.1.3.1.1.15 | ColumnnbsSffDiagsOptSoftRxLoSMonitoring | read-only | current | Based on byte 93 bit 4. Optional soft RX_LOS monitoring implemented. Sets to 1 if not implemented, 2 if implemented. |
| 1.3.6.1.4.1.629.204.1.3.1.1.16 | ColumnnbsSffDiagsOptSoftTxFaultMonitoring | read-only | current | Based on byte 93 bit 5. Optional soft TX_FAULT monitoring implemented. Sets to 1 if not implemented, 2 if implemented. |
| 1.3.6.1.4.1.629.204.1.3.1.1.17 | ColumnnbsSffDiagsOptSoftTxDisable | read-only | current | Based on byte 93 bit 6. Optional soft TX_DISABLE control and monitoring implemented.Sets to 1 if not implemented, 2 if implemented. |
| 1.3.6.1.4.1.629.204.1.3.1.1.18 | ColumnnbsSffDiagsOptAlarmWarningFlags | read-only | current | Based on byte 93 bit 7. Optional Alarm/warning flags implemented for all monitored quantities.Sets to 1 if not implemented, 2 if implemented. See Table 3.18 |
| 1.3.6.1.4.1.629.204.1.3.1.1.19 | ColumnnbsSffDiags8472Compliance | read-only | current | Byte 94 contains an unsigned integer that indicates which feature set(s) are implemented in the transceiver. |
| 1.3.6.1.4.1.629.204.1.3.1.1.20 | ColumnnbsSffDiagsTemperature | read-only | current | Module temperature in centigradese. |
| 1.3.6.1.4.1.629.204.1.3.1.1.21 | ColumnnbsSffDiagsTempLowAlarm | read-only | current | Predefined temperature for low alarm threshold in Centigrades. |
| 1.3.6.1.4.1.629.204.1.3.1.1.22 | ColumnnbsSffDiagsTempLowWarn | read-only | current | Predefined temperature for low warning threshold in Centigrades |
| 1.3.6.1.4.1.629.204.1.3.1.1.23 | ColumnnbsSffDiagsTempHighWarn | read-only | current | Predefined temperature for high warning threshold in Centigrades |
| 1.3.6.1.4.1.629.204.1.3.1.1.24 | ColumnnbsSffDiagsTempHighAlarm | read-only | current | Predefined temperature for high alarm threshold in Centigrades |
| 1.3.6.1.4.1.629.204.1.3.1.1.25 | ColumnnbsSffDiagsVoltage | read-only | current | Internally measured supply voltage in transceiver in the units of Volts. Bytes 98 & 99 of Address A2h |
| 1.3.6.1.4.1.629.204.1.3.1.1.26 | ColumnnbsSffDiagsVoltLowAlarm | read-only | current | Predefined voltage for low alarm threshold in the units of Volts. |
| 1.3.6.1.4.1.629.204.1.3.1.1.27 | ColumnnbsSffDiagsVoltLowWarn | read-only | current | Predefined voltage for low warning threshold in the units of Volts. |
| 1.3.6.1.4.1.629.204.1.3.1.1.28 | ColumnnbsSffDiagsVoltHighWarn | read-only | current | Predefined voltage for high warning threshold in the units of Volts. |
| 1.3.6.1.4.1.629.204.1.3.1.1.29 | ColumnnbsSffDiagsVoltHighAlarm | read-only | current | Predefined voltage for high alarm threshold in the units of Volts. |
| 1.3.6.1.4.1.629.204.1.3.1.1.30 | ColumnnbsSffDiagsBiasCurrent | read-only | current | Internally measured TX Bias Current in the units of mA. Bytes 100 & 101 of Address A2h |
| 1.3.6.1.4.1.629.204.1.3.1.1.31 | ColumnnbsSffDiagsBiasLowAlarm | read-only | current | Predefined bias current for low alarm threshold in the units of mA |
| 1.3.6.1.4.1.629.204.1.3.1.1.32 | ColumnnbsSffDiagsBiasLowWarn | read-only | current | Predefined bias current for low warning threshold in the units of mA |
| 1.3.6.1.4.1.629.204.1.3.1.1.33 | ColumnnbsSffDiagsBiasHighWarn | read-only | current | Predefined bias current for high warning threshold in the units of mA |
| 1.3.6.1.4.1.629.204.1.3.1.1.34 | ColumnnbsSffDiagsBiasHighAlarm | read-only | current | Predefined bias current for high alarm threshold in the units of mA |
| 1.3.6.1.4.1.629.204.1.3.1.1.35 | ColumnnbsSffDiagsTxPower | read-only | current | Measured TX output power in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.36 | ColumnnbsSffDiagsTxPowerLowAlarm | read-only | current | Predefined Tx output power for low alarm threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.37 | ColumnnbsSffDiagsTxPowerLowWarn | read-only | current | Predefined Tx output power for low warning threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.38 | ColumnnbsSffDiagsTxPowerHighWarn | read-only | current | Predefined Tx output power for high warning threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.39 | ColumnnbsSffDiagsTxPowerHighAlarm | read-only | current | Predefined Tx output power for high alarm threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.40 | ColumnnbsSffDiagsRxPower | read-only | current | Measured received optical power. Received power, RX_PWR, is given in uW by the following equation: Rx_PWR (uW) = Rx_PWR(4) * Rx_PWR AD 4 (16 bit unsigned integ… |
| 1.3.6.1.4.1.629.204.1.3.1.1.41 | ColumnnbsSffDiagsRxPowerLowAlarm | read-only | current | Predefined Rx input power for low alarm threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.42 | ColumnnbsSffDiagsRxPowerLowWarn | read-only | current | Predefined Rx input power for low warning threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.43 | ColumnnbsSffDiagsRxPowerHighWarn | read-only | current | Predefined Rx input power for high warning threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.44 | ColumnnbsSffDiagsRxPowerHighAlarm | read-only | current | Predefined Rx input power for high alarm threshold in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.45 | ColumnnbsSffDiagsDataReadyBarState | read-only | current | Indicates transceiver has achieved power up and data is ready. Bit remains high until data is ready to be read at which time the device sets the bit low. Byte … |
| 1.3.6.1.4.1.629.204.1.3.1.1.46 | ColumnnbsSffDiagsRxLosState | read-only | current | Digital state of the RX_LOS Output Pin. Updated within 100ms of change on pin. Byte 110, bit 1 of A2h |
| 1.3.6.1.4.1.629.204.1.3.1.1.47 | ColumnnbsSffDiagsTxFaultState | read-only | current | Digital state of the TX Fault Output Pin. Updated within 100ms of change on pin. Byte 110, bit 2 of A2h |
| 1.3.6.1.4.1.629.204.1.3.1.1.48 | ColumnnbsSffDiagsSoftRateSelect | read-only | current | Read/write bit that allows software rate select control. Writing 1 selects full bandwidth operation. This bit is OR'd with the hard Rate_Select, AS(0) or RS(0)… |
| 1.3.6.1.4.1.629.204.1.3.1.1.49 | ColumnnbsSffDiagsRateSelectState0 | read-only | current | Digital state of the SFP Rate_Select Input Pin. Updated within 100ms of change on pin. Note: This pin is also known as AS(0) in SFF-8079 and RS(0) in SFF-8431.… |
| 1.3.6.1.4.1.629.204.1.3.1.1.50 | ColumnnbsSffDiagsRS1State | read-only | current | Reserved for digital state of input pin AS(1) per SFF-8079 and RS(1) per SFF-8431. Updated within 100ms of change on pin. See A2h Byte 118, Bit 3 for Soft RS(1… |
| 1.3.6.1.4.1.629.204.1.3.1.1.51 | ColumnnbsSffDiagsSoftTxDisableSelect | read-only | current | Read/write bit that allows software disable of laser. Writing 1 disables laser. See Table 3.11 for enable/ disable timing requirements. This bit is OR d with t… |
| 1.3.6.1.4.1.629.204.1.3.1.1.52 | ColumnnbsSffDiagsTxDisableState | read-only | current | Digital state of the TX Disable Input Pin. Updated within 100ms of change on pin. |
| 1.3.6.1.4.1.629.204.1.3.1.1.53 | ColumnnbsSffDiagsBiasCurrentSlope | read-only | current | Fixed decimal (unsigned) calibration data, laser bias current measured in mA. |
| 1.3.6.1.4.1.629.204.1.3.1.1.54 | ColumnnbsSffDiagsBiasCurrentOffset | read-only | current | Fixed decimal (signed two's complement) calibration data, laser bias current measured in mA. |
| 1.3.6.1.4.1.629.204.1.3.1.1.55 | ColumnnbsSffDiagsTxPowerSlope | read-only | current | Fixed decimal (unsigned) calibration data, transmitter coupled output power in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.56 | ColumnnbsSffDiagsTxPowerOffset | read-only | current | Fixed decimal (signed two's complement) calibration data, transmitter coupled output power in the units of dBm. |
| 1.3.6.1.4.1.629.204.1.3.1.1.57 | ColumnnbsSffDiagsTemperatureSlope | read-only | current | Fixed decimal (unsigned) calibration data, internal module temperature in C |
| 1.3.6.1.4.1.629.204.1.3.1.1.58 | ColumnnbsSffDiagsTemperatureOffset | read-only | current | Fixed decimal (signed two's complement) calibration data, internal module temperature in C |
| 1.3.6.1.4.1.629.204.1.3.1.1.59 | ColumnnbsSffDiagsVoltageSlope | read-only | current | Fixed decimal (unsigned) calibration data, internal module supply voltage in Volts. |
| 1.3.6.1.4.1.629.204.1.3.1.1.60 | ColumnnbsSffDiagsVoltageOffset | read-only | current | Fixed decimal (signed two's complement) calibration data, internal module supply voltage in Volts. |
| 1.3.6.1.4.1.629.204.1.3.1.1.61 | ColumnnbsSffDiagsPowerLevelSelect | read-only | current | Reserved for SFF-8431 Power Level (maximum power dissipation) enable. Value of zero disables Power Level 2 (1.0 Watt max). Value of one enables Power Level 2 (… |
| 1.3.6.1.4.1.629.204.1.3.1.1.62 | ColumnnbsSffDiagsPowerLevelOpState | read-only | current | Reserved for SFF-8431 Power Level (maximum power dissipation) status.Value of zero indicates Power Level 1 operation (1.0 Watt max) Value of one indicates Powe… |
| 1.3.6.1.4.1.629.204.1.3.1.1.63 | ColumnnbsSffDiagsSoftRSSelect | read-only | current | Read/write bit that allows software Tx rate control. Writing 1 selects full speed Tx operation. This bit is OR d with the hard RS(1) pin value.See Table 3.11 f… |
| 1.3.6.1.4.1.629.204.1.4 | IdentitynbsSffMsxGrp | current | All SFF MSA Extension objects. | |
| 1.3.6.1.4.1.629.204.1.4.1 | ScalarnbsSffMsxTableSize | read-only | current | The number of entries in nbsSffMsxTable |
| 1.3.6.1.4.1.629.204.1.4.2 | TablenbsSffMsxTable | not-accessible | current | Non-standardized extensions to the Multi-Source Agreement |
| 1.3.6.1.4.1.629.204.1.4.2.1 | RownbsSffMsxEntry | not-accessible | current | Pluggable Transceiver information and settings yet to be standardized |
| 1.3.6.1.4.1.629.204.1.4.2.1.1 | ColumnnbsSffMsxPhysicalIfIndex | read-only | current | MIB2 ifIndex of this port |
| 1.3.6.1.4.1.629.204.1.4.2.1.2 | ColumnnbsSffMsxHasSgmiiPhy | read-write | current | Some Gigabit Ethernet compatible SFP transeivers, such as SFP-FDSGMII-M and SFP-FDSGMII-LR, have a built-in SGMII PHY. Those that do require special autonegoti… |