MIB Viewer

NBS-SIGCOND-MIB

68 objects
Signal Conditioning mib
Imported Objects
IF-MIBifAlias InterfaceIndex
NBS-MIBnbs NbsTcMHz NbsTcMilliDb
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.629.227IdentitynbsSigCondMibSignal Conditioning mib
1.3.6.1.4.1.629.227.1IdentitynbsSigCondVoaPortGrpcurrentVariable Optical Attenuation at the port level.
1.3.6.1.4.1.629.227.1.1ScalarnbsSigCondVoaPortTableSizeread-onlycurrentThe number of ports supporting variable optical attenuation at the port level.
1.3.6.1.4.1.629.227.1.2TablenbsSigCondVoaPortTablenot-accessiblecurrentList of ports supporting variable optical attenuation at the port level.
1.3.6.1.4.1.629.227.1.2.1RownbsSigCondVoaPortEntrynot-accessiblecurrent
1.3.6.1.4.1.629.227.1.2.1.1ColumnnbsSigCondVoaPortIfIndexnot-accessiblecurrentThe Mib2 ifIndex of the attenuable port.
1.3.6.1.4.1.629.227.1.2.1.2ColumnnbsSigCondVoaPortRxAttenuAdminread-writecurrentPersistent and immediately updated. User-requested attenuation to be applied to received signal, expressed in millidecibels (mdB). Not supported value: -200000
1.3.6.1.4.1.629.227.1.2.1.3ColumnnbsSigCondVoaPortRxAttenuOperread-onlycurrentAttenuation actually being applied to received signal, in millidecibels (mdB). Not supported value: -200000
1.3.6.1.4.1.629.227.1.2.1.4ColumnnbsSigCondVoaPortTxAttenuAdminread-writecurrentPersistent and immediately updated. User-requested attenuation to be applied before transmitting signal, expressed in millidecibels (mdB). Not supported value:…
1.3.6.1.4.1.629.227.1.2.1.5ColumnnbsSigCondVoaPortTxAttenuOperread-onlycurrentAttenuation actually being applied before transmitting signal, in millidecibels (mdB). Not supported value: -200000
1.3.6.1.4.1.629.227.2IdentitynbsSigCondVoaChannelGrpcurrentVariable Optical Attenuation at the channel level.
1.3.6.1.4.1.629.227.2.1ScalarnbsSigCondVoaChannelRangeTableSizeread-onlycurrentThe number of mux ports supporting variable optical attenuation at the channel level.
1.3.6.1.4.1.629.227.2.2TablenbsSigCondVoaChannelRangeTablenot-accessiblecurrentThe channel attenuation values supported on this port.
1.3.6.1.4.1.629.227.2.2.1RownbsSigCondVoaChannelRangeEntrynot-accessiblecurrent
1.3.6.1.4.1.629.227.2.2.1.1ColumnnbsSigCondVoaChannelRangeIfIndexnot-accessiblecurrentThe Mib2 ifIndex of the mux port.
1.3.6.1.4.1.629.227.2.2.1.2ColumnnbsSigCondVoaChannelRangeMinread-onlycurrentThe lowest channel attenuation value supported by this mux port, expressed in millidecibels (mdB). This is the smallest attenuation supported.
1.3.6.1.4.1.629.227.2.2.1.3ColumnnbsSigCondVoaChannelRangeMaxread-onlycurrentThe greatest channel attenuation value supported by this mux port, expressed in millidecibels (mdB). This is the largest attenuation supported.
1.3.6.1.4.1.629.227.2.2.1.4ColumnnbsSigCondVoaChannelRangeIncrread-onlycurrentThe precision of the VOA, expressed in millidecibels (mdB). The minimum difference between attenuation values.
1.3.6.1.4.1.629.227.3IdentitynbsSigCondRamanGrpcurrentRaman amplifier information for the port.
1.3.6.1.4.1.629.227.3.1ScalarnbsSigCondRamanTableSizeread-onlycurrentThe number of raman ports in this system.
1.3.6.1.4.1.629.227.3.2TablenbsSigCondRamanTablenot-accessiblecurrentTable of Raman readings.
1.3.6.1.4.1.629.227.3.2.1RownbsSigCondRamanEntrynot-accessiblecurrentRaman readings on an individual port.
1.3.6.1.4.1.629.227.3.2.1.1ColumnnbsSigCondRamanIfIndexnot-accessiblecurrentThe Mib2 ifIndex of the Raman port
1.3.6.1.4.1.629.227.3.2.1.2ColumnnbsSigCondRamanPumpPwrAdminread-writecurrentPersistent and immediately updated. User-requested pump power, in microwatts (uW). User interfaces should show this in millWatts (mW). Not supported value: -1
1.3.6.1.4.1.629.227.3.2.1.3ColumnnbsSigCondRamanPumpPwrOperread-onlycurrentAgent reported pump power, in microwatts (uW). User interfaces should show this in millWatts (mW). Not supported value: -1
1.3.6.1.4.1.629.227.20IdentitynbsSigCondEqualizeGrpcurrentManagement info for equalizing power levels among channels within a WDM port
1.3.6.1.4.1.629.227.20.1ScalarnbsSigCondEqualizeTableSizeread-onlycurrentThe number of entries in nbsSigCondEqualizeTable.
1.3.6.1.4.1.629.227.20.2TablenbsSigCondEqualizeTablenot-accessiblecurrentList of WDM ports supporting power level equalization.
1.3.6.1.4.1.629.227.20.2.1RownbsSigCondEqualizeEntrynot-accessiblecurrentEqualization parameters and settings
1.3.6.1.4.1.629.227.20.2.1.1ColumnnbsSigCondEqualizeIfIndexread-onlycurrentThe Mib2 ifIndex of this channel's WDM port
1.3.6.1.4.1.629.227.20.2.1.10ColumnnbsSigCondEqualizeStateread-writecurrentUsed to enable or disable channel equalization on this port. The value disabled(2) disables the feature. No attempt to equalize power levels will be made, and …
1.3.6.1.4.1.629.227.20.2.1.11ColumnnbsSigCondEqualizeLimitMinread-onlycurrentThe lowest channel TxPower setting the equalizer supports
1.3.6.1.4.1.629.227.20.2.1.12ColumnnbsSigCondEqualizeLimitMaxread-onlycurrentThe highest channel TxPower setting the equalizer supports
1.3.6.1.4.1.629.227.20.2.1.21ColumnnbsSigCondEqualizeDesiredMinread-writecurrentThe user-settable minimum channel TxPower level. Allowed values are from nbsSigCondEqualizeLimitMin to nbsSigCondEqualizeLimitMax, inclusive. Equalizer must at…
1.3.6.1.4.1.629.227.20.2.1.22ColumnnbsSigCondEqualizeDesiredMaxread-writecurrentThe user-settable maximum channel TxPower level. Allowed values are from nbsSigCondEqualizeLimitMin to nbsSigCondEqualizeLimitMax, inclusive. Equalizer must at…
1.3.6.1.4.1.629.227.20.2.1.23ColumnnbsSigCondEqualizeDesiredValread-writecurrentEqualizer must attempt to maintain the channels' signal at this level. Allowed values are from nbsSigCondEqualizeLimitMin to nbsSigCondEqualizeLimitMax, inclus…
1.3.6.1.4.1.629.227.30IdentitynbsSigCondRedundGrpcurrentManagement info for power level based redundancy
1.3.6.1.4.1.629.227.30.1ScalarnbsSigCondRedundTableSizeread-onlycurrentThe number of entries in nbsSigCondRedund.
1.3.6.1.4.1.629.227.30.2TablenbsSigCondRedundTablenot-accessiblecurrentList of ports supporting power level redundancy.
1.3.6.1.4.1.629.227.30.2.1RownbsSigCondRedundEntrynot-accessiblecurrentRedundancy settings
1.3.6.1.4.1.629.227.30.2.1.1ColumnnbsSigCondRedundIfIndexread-onlycurrentThe Mib2 ifIndex of this channel's Redundancy port
1.3.6.1.4.1.629.227.30.2.1.5ColumnnbsSigCondRedundLimitMinread-onlycurrentThe lowest channel Power setting
1.3.6.1.4.1.629.227.30.2.1.8ColumnnbsSigCondRedundLimitMaxread-onlycurrentThe highest channel Power setting
1.3.6.1.4.1.629.227.30.2.1.10ColumnnbsSigCondRedundDesiredMinread-writecurrentThe lowest channel Power setting before the redundancy kicks in
1.3.6.1.4.1.629.227.30.2.1.15ColumnnbsSigCondRedundDesiredMaxread-writecurrentThe highest channel Power setting before the redundancy kicks in
1.3.6.1.4.1.629.227.40IdentitynbsSigCondPortGrpcurrentPower readings from the port.
1.3.6.1.4.1.629.227.40.1ScalarnbsSigCondPortTableSizeread-onlycurrentThe number of entries in nbsSigCondPortTable.
1.3.6.1.4.1.629.227.40.2TablenbsSigCondPortTablenot-accessiblecurrentTable of VOA and VGA ports.
1.3.6.1.4.1.629.227.40.2.1RownbsSigCondPortEntrynot-accessiblecurrent
1.3.6.1.4.1.629.227.40.2.1.1ColumnnbsSigCondPortIfIndexnot-accessiblecurrentThe Mib2 ifIndex of the port
1.3.6.1.4.1.629.227.40.2.1.2ColumnnbsSigCondPortRxPowerread-onlycurrentMeasured receiver power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
1.3.6.1.4.1.629.227.40.2.1.3ColumnnbsSigCondPortTxPowerread-onlycurrentMeasured transmitter power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
1.3.6.1.4.1.629.227.40.2.1.4ColumnnbsSigCondPortReflectionread-onlycurrentMeasured back reflection power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
1.3.6.1.4.1.629.227.50IdentitynbsSigCondChannelGrpcurrentSignal info for WDM channels within a WDM port
1.3.6.1.4.1.629.227.50.1ScalarnbsSigCondChannelTableSizeread-onlycurrentThe number of entries in nbsSigCondChannelTable.
1.3.6.1.4.1.629.227.50.2TablenbsSigCondChannelTablenot-accessiblecurrentWDM channels within a mux port
1.3.6.1.4.1.629.227.50.2.1RownbsSigCondChannelEntrynot-accessiblecurrent
1.3.6.1.4.1.629.227.50.2.1.1ColumnnbsSigCondChannelIfIndexnot-accessiblecurrentThe Mib2 ifIndex of this channel's mux port
1.3.6.1.4.1.629.227.50.2.1.2ColumnnbsSigCondChannelCenterlineread-onlycurrentThe center frequency of this channel, in MHz
1.3.6.1.4.1.629.227.50.2.1.11ColumnnbsSigCondChannelRxPowerread-onlycurrentThe dynamically measured or calculated receive signal strength
1.3.6.1.4.1.629.227.50.2.1.12ColumnnbsSigCondChannelTxPowerread-onlycurrentThe dynamically measured or calculated transmit signal strength
1.3.6.1.4.1.629.227.50.2.1.14ColumnnbsSigCondChannelTxAttenuread-onlycurrentThe actual attenuation applied to this channel, possibly representing changes made by the equalization process if nbsSigCondEqualizeState is enabled for this I…
1.3.6.1.4.1.629.227.50.2.1.15ColumnnbsSigCondChannelRxAttenuread-onlycurrentThe actual attenuation applied to this channel, possibly representing changes made by the equalization process if nbsSigCondEqualizeState is enabled for this I…
1.3.6.1.4.1.629.227.200IdentitynbsSigCondTrapscurrentSNMP Traps or Notifications
1.3.6.1.4.1.629.227.200.0IdentitynbsSigCondEventcurrentSNMP Traps or Notifications
1.3.6.1.4.1.629.227.200.0.20NotificationnbsSigCondEventEqualizeOkcurrentSent when equalizer becomes able to maintain TxPower within the user-specified nbsSigCondEqualizeDesired range. This Notification is of severity ERROR, which m…
1.3.6.1.4.1.629.227.200.0.21NotificationnbsSigCondEventEqualizeTooLowcurrentSent when equalizer becomes unable to maintain TxPower at or above nbsSigCondEqualizeDesiredMin. This Notification is of severity ERROR, which means it should …
1.3.6.1.4.1.629.227.200.0.22NotificationnbsSigCondEventEqualizeTooHighcurrentSent when equalizer becomes unable to maintain TxPower at or below nbsSigCondEqualizeDesiredMax. This Notification is of severity ERROR, which means it should …