The Broadcom Private MIB for FASTPATH for system time, timezone and summer-time settings
Imported Objects
NETAPP-REF-MIBfastPath
RFC1213-MIBDisplayString
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.789.4413.1.1.42IdentityfastPathTimeZonePrivateThe Broadcom Private MIB for FASTPATH for system time, timezone and summer-time settings
1.3.6.1.4.1.789.4413.1.1.42.1NodeagentSystemTimeGroup
1.3.6.1.4.1.789.4413.1.1.42.1.1ScalaragentSystemTimeread-writecurrentthe current sytem time (includes the TimeZone offset and summertime Offset) Only in the case of platforms supporting Real Time Clock, this object can be set
1.3.6.1.4.1.789.4413.1.1.42.1.2ScalaragentSystemDateread-writecurrentthe current sytem date. Only in the case of platforms supporting Real Time Clock, this object can be set and range is Jan 01 2010 to Dec 31 2079
1.3.6.1.4.1.789.4413.1.1.42.1.3ScalaragentSystemTimeZoneAcronymread-onlycurrentthe zone acronym of summertime when summertime is in effect If summer-time is not in effect or if there is no acronym for summer-time it defaults To TimeZone a…
1.3.6.1.4.1.789.4413.1.1.42.1.4ScalaragentSystemTimeSourceread-onlycurrentthe time source from which the time update is taken.
1.3.6.1.4.1.789.4413.1.1.42.1.5ScalaragentSystemSummerTimeStateread-onlycurrentenabled : summer-time is in effect currently disabled : summer-time is not in effect currently
1.3.6.1.4.1.789.4413.1.1.42.2NodeagentTimeZoneGroup
1.3.6.1.4.1.789.4413.1.1.42.2.1ScalaragentTimeZoneHoursOffsetread-writecurrentthe hours to be added to the UTC time
1.3.6.1.4.1.789.4413.1.1.42.2.2ScalaragentTimeZoneMinutesOffsetread-writecurrentthe minutes to be added to the UTC time.
1.3.6.1.4.1.789.4413.1.1.42.2.3ScalaragentTimeZoneAcronymread-writecurrentthe acronym associated with the zone.
1.3.6.1.4.1.789.4413.1.1.42.3NodeagentSummerTimeGroup
1.3.6.1.4.1.789.4413.1.1.42.3.1ScalaragentSummerTimeModeread-writecurrentrecurring- set the parameters for recurring summer-time non-recurring- set the parameters for non-recurring summer-time no-summertime- disable the summer-time
1.3.6.1.4.1.789.4413.1.1.42.3.2NodeagentSummerTimeRecurringGroup
1.3.6.1.4.1.789.4413.1.1.42.3.2.1ScalaragentStRecurringStartingWeekread-writecurrentthe week of the month from which the summer-time should be effective.
1.3.6.1.4.1.789.4413.1.1.42.3.2.2ScalaragentStRecurringStartingDayread-writecurrentthe day of the agentStRecurringStartingWeek from which the summer-time should be effective.
1.3.6.1.4.1.789.4413.1.1.42.3.2.3ScalaragentStRecurringStartingMonthread-writecurrentthe month of the year from which the summer-time should be effective.
1.3.6.1.4.1.789.4413.1.1.42.3.2.4ScalaragentStRecurringStartingTimeread-writecurrentthe time in the hh:mm format from which the summer-time should be effective. range for hh: 0 to 23 range for mm: 0 to 59
1.3.6.1.4.1.789.4413.1.1.42.3.2.5ScalaragentStRecurringEndingWeekread-writecurrentthe week of the Month in which the summer-time should end.
1.3.6.1.4.1.789.4413.1.1.42.3.2.6ScalaragentStRecurringEndingDayread-writecurrentthe day of the agentStRecurringStartingWeek on which the summer-time should end.
1.3.6.1.4.1.789.4413.1.1.42.3.2.7ScalaragentStRecurringEndingMonthread-writecurrentthe month of the year in which the summer-time should end.
1.3.6.1.4.1.789.4413.1.1.42.3.2.8ScalaragentStRecurringEndingTimeread-writecurrentthe time of the agentStRecurringEndingDay in hh:mm format at which the summer-time should end. range for hh: 0 to 23 range for mm: 0 to 59
1.3.6.1.4.1.789.4413.1.1.42.3.2.9ScalaragentStRecurringZoneAcronymread-writecurrentthe zone associated with the summer-time recurring configuration. the acronym maximum legth is 4 characters
1.3.6.1.4.1.789.4413.1.1.42.3.2.10ScalaragentStRecurringZoneOffsetread-writecurrentthe zone offset in minutes which will be added to the UTC time during the summer-time of every year.
1.3.6.1.4.1.789.4413.1.1.42.3.3NodeagentSummerTimeNonRecurringGroup
1.3.6.1.4.1.789.4413.1.1.42.3.3.1ScalaragentStNonRecurringStartingDayread-writecurrentthe day of the agentStNonRecurringStartingMonth from which the summer-time should be effective.
1.3.6.1.4.1.789.4413.1.1.42.3.3.2ScalaragentStNonRecurringStartingMonthread-writecurrentthe Month of the agentStNonRecurringStartingYear from which the summer-time should be effective.
1.3.6.1.4.1.789.4413.1.1.42.3.3.3ScalaragentStNonRecurringStartingYearread-writecurrentthe year from which the summer-time should be effective.
1.3.6.1.4.1.789.4413.1.1.42.3.3.4ScalaragentStNonRecurringStartingTimeread-writecurrentthe time in the hh:mm format. The time of agentStNonRecurringStartingDay from which the summer-time should be effective. range for hh: 0 to 23 range for mm: 0 …
1.3.6.1.4.1.789.4413.1.1.42.3.3.5ScalaragentStNonRecurringEndingDayread-writecurrentthe day of the agentStNonRecurringEndingMonth on which the summer-time should end.
1.3.6.1.4.1.789.4413.1.1.42.3.3.6ScalaragentStNonRecurringEndingMonthread-writecurrentthe month of the agentStNonRecurringEndingYear in which the summer-time should end.
1.3.6.1.4.1.789.4413.1.1.42.3.3.7ScalaragentStNonRecurringEndingYearread-writecurrentthe year in which the summer-time should end.
1.3.6.1.4.1.789.4413.1.1.42.3.3.8ScalaragentStNonRecurringEndingTimeread-writecurrentthe time on the agentStNonRecurringEndingDay in hh:mm format at which the summer-time should end. range for hh: 0 to 23 range for mm: 0 to 59
1.3.6.1.4.1.789.4413.1.1.42.3.3.9ScalaragentStNonRecurringZoneOffsetread-writecurrentthe zone offset in minutes which will be added to the UTC time during the summer-time.
1.3.6.1.4.1.789.4413.1.1.42.3.3.10ScalaragentStNonRecurringZoneAcronymread-writecurrentthe zone associated with the summer-time non recurring configuration. the acronym maximum legth is 4 characters