MIB Viewer

NETGEAR-BOXSERVICES-OLD-MIB

33 objects
The NETGEAR Private MIB for FASTPATH Box Services Feature.
Imported Objects
NETGEAR-REF-MIBng7000managedswitch
RFC1213-MIBDisplayString
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.4526.10.43IdentityfastPathBoxServicesThe NETGEAR Private MIB for FASTPATH Box Services Feature.
1.3.6.1.4.1.4526.10.43.0NodefastPathBoxServicesTraps
1.3.6.1.4.1.4526.10.43.0.1NotificationboxsFanStateChangecurrentTrap is sent when fan state change happens.
1.3.6.1.4.1.4526.10.43.0.2NotificationboxsPowSupplyStateChangecurrentTrap is sent when power supply state change happens.
1.3.6.1.4.1.4526.10.43.0.3NotificationboxsTemperatureChangecurrentTrap is sent when temperature is changing and crossing any of the thresholds
1.3.6.1.4.1.4526.10.43.1NodeboxServicesGroup
1.3.6.1.4.1.4526.10.43.1.1ScalarboxServicesNormalTempRangeMinread-writecurrentLower boundary of normal temperature range.
1.3.6.1.4.1.4526.10.43.1.2ScalarboxServicesNormalTempRangeMaxread-writecurrentUpper boundary of normal temperature range.
1.3.6.1.4.1.4526.10.43.1.3ScalarboxServicesTemperatureTrapEnableread-writecurrentEnable or disable temperature change event trap, raised when temperature crosses boundaries of normal range
1.3.6.1.4.1.4526.10.43.1.4ScalarboxServicesPSMStateTrapEnableread-writecurrentEnable or disable Power Supply Module state change trap.
1.3.6.1.4.1.4526.10.43.1.5ScalarboxServicesFanStateTrapEnableread-writecurrentEnable or disable Fan state change trap.
1.3.6.1.4.1.4526.10.43.1.6TableboxServicesFansTablenot-accessiblecurrentFan
1.3.6.1.4.1.4526.10.43.1.6.1RowboxServicesFansEntrynot-accessiblecurrentBox Services Fan Entry
1.3.6.1.4.1.4526.10.43.1.6.1.1ColumnboxServicesFansIndexread-onlycurrentUnique index of fan table entry
1.3.6.1.4.1.4526.10.43.1.6.1.2ColumnboxServicesFanItemTyperead-onlycurrentThe type of fan
1.3.6.1.4.1.4526.10.43.1.6.1.3ColumnboxServicesFanItemStateread-onlycurrentThe status of fan
1.3.6.1.4.1.4526.10.43.1.6.1.4ColumnboxServicesFanSpeedread-onlycurrentThe speed of fan
1.3.6.1.4.1.4526.10.43.1.6.1.5ColumnboxServicesFanDutyLevelread-onlycurrentThe duty level of fan, in percents
1.3.6.1.4.1.4526.10.43.1.7TableboxServicesPowSuppliesTablenot-accessiblecurrentPower supply
1.3.6.1.4.1.4526.10.43.1.7.1RowboxServicesPowSuppliesEntrynot-accessiblecurrentBox Services Power Supply Entry
1.3.6.1.4.1.4526.10.43.1.7.1.1ColumnboxServicesPowSupplyIndexread-onlycurrentUnique index of power supply table entry
1.3.6.1.4.1.4526.10.43.1.7.1.2ColumnboxServicesPowSupplyItemTyperead-onlycurrentThe type of power supply
1.3.6.1.4.1.4526.10.43.1.7.1.3ColumnboxServicesPowSupplyItemStateread-onlycurrentThe status of power supply
1.3.6.1.4.1.4526.10.43.1.8TableboxServicesTempSensorsTablenot-accessiblecurrentTemperature sensor
1.3.6.1.4.1.4526.10.43.1.8.1RowboxServicesTempSensorsEntrynot-accessiblecurrentBox Services Temperature Sensor Entry
1.3.6.1.4.1.4526.10.43.1.8.1.1ColumnboxServicesTempSensorIndexread-onlycurrentUnique index of temperature sensor table entry
1.3.6.1.4.1.4526.10.43.1.8.1.2ColumnboxServicesTempSensorTyperead-onlycurrentThe type of temperature sensor
1.3.6.1.4.1.4526.10.43.1.8.1.3ColumnboxServicesTempSensorStateread-onlycurrentThe state of temperature sensor
1.3.6.1.4.1.4526.10.43.1.8.1.4ColumnboxServicesTempSensorTemperatureread-onlycurrentThe temperature value reported by sensor
1.3.6.1.4.1.4526.10.43.1.9ScalarboxServicesCPLDCodeVersionread-onlycurrentThe CPLD code version of the unit.
1.3.6.1.4.1.4526.10.43.2NodeboxServicesNotificationsGroup
1.3.6.1.4.1.4526.10.43.2.1ScalarboxsItemStateChangeEventread-onlycurrentThis event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply …
1.3.6.1.4.1.4526.10.43.2.2ScalarboxsTemperatureChangeEventread-onlycurrentThis event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around…