MIB Viewer

NETIO-PRODUCTS-NETIO-MIB

22 objects
Netio specific data structures
Imported Objects
SNMPv2-SMIenterprises MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDateAndTime
OIDNameAccessStatusDescription
1.3.6.1.4.1.47952IdentitynetioProductsNetio specific data structures
1.3.6.1.4.1.47952.1Nodenetio4
1.3.6.1.4.1.47952.1.1TablenetioOutputTablenot-accessiblecurrentThis table contains current status of Netio outputs.
1.3.6.1.4.1.47952.1.1.1RownetioOutputEntrynot-accessiblecurrentA row describing one netio output.
1.3.6.1.4.1.47952.1.1.1.1ColumnnetioOutputIDread-onlycurrentOutput number.
1.3.6.1.4.1.47952.1.1.1.2ColumnnetioOutputNameread-onlycurrentDescription of the output given by user.
1.3.6.1.4.1.47952.1.1.1.3ColumnnetioOutputStateread-onlycurrentCurrent output state.
1.3.6.1.4.1.47952.1.1.1.4ColumnnetioOutputStateStringread-onlycurrentCurrent output state (string).
1.3.6.1.4.1.47952.1.1.1.5ColumnnetioOutputActionread-writecurrentCommand to control output.
1.3.6.1.4.1.47952.1.1.1.25ColumnnetioOutputLoadread-onlycurrentCurrent power consumption in Watts. 0 when power meters are not available
1.3.6.1.4.1.47952.1.1.1.26ColumnnetioOutputEnergyread-onlycurrentCumulated consumption from netioOutputEnergyStart. In Wh. 0 when power meters are not available.
1.3.6.1.4.1.47952.1.1.1.27ColumnnetioOutputEnergyStartread-onlycurrentStart time from which energy is counted. UTC based. for backward compatibility only, is the same for all outputs. use netioGlobalMeasure.netioEnergyStart inste…
1.3.6.1.4.1.47952.1.1.1.28ColumnnetioOutputCurrentread-onlycurrentCurrent current in mA. 0 when power meters are not available
1.3.6.1.4.1.47952.1.1.1.29ColumnnetioOutputPowerFactorread-onlycurrentCurrent power factor * 1000. 0 when power meters are not available
1.3.6.1.4.1.47952.1.2NodenetioGlobalMeasure
1.3.6.1.4.1.47952.1.2.1ScalarnetioVoltageread-onlycurrentVoltage in the power grid in mV. 0 when power meters are not available
1.3.6.1.4.1.47952.1.2.2ScalarnetioFrequencyread-onlycurrentFrequency in the power grid in mHz. 0 when power meters are not available
1.3.6.1.4.1.47952.1.2.3ScalarnetioTotalCurrentread-onlycurrentTotal current for all outputs in mA. 0 when power meters are not available
1.3.6.1.4.1.47952.1.2.4ScalarnetioOverallPowerFactorread-onlycurrentOverall power factor across all outputs. 0 when power meters are not available
1.3.6.1.4.1.47952.1.2.5ScalarnetioTotalLoadread-onlycurrentTotal load for all outputs in W. 0 when power meters are not available
1.3.6.1.4.1.47952.1.2.6ScalarnetioTotalEnergyread-onlycurrentTotal energy for all outputs in Wh starting from netioEnergyStart. 0 when power meters are not available
1.3.6.1.4.1.47952.1.2.7ScalarnetioEnergyStartread-onlycurrentStart time from which energy is counted. UTC based.