44 objects
Newtec modular ASI input MIB containing definitions for ASI input functionality.
Imported Objects
FLOAT-TC-MIB MISSINGFloat32TC
NEWTEC-MAIN-MIBntcFunction
NEWTEC-TC-MIBNtcAlarmState NtcEnable NtcPid
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Integer32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.5835.5.2.800IdentityntcAsiInNewtec modular ASI input MIB containing definitions for ASI input functionality.
1.3.6.1.4.1.5835.5.2.800.1IdentityntcAsiInObjectscurrentContainer holding ntcAsiInObjects definitions.
1.3.6.1.4.1.5835.5.2.800.1.1ScalarntcAsiInInputSelectionread-writecurrentConfiguration of the ASI external input interface.
1.3.6.1.4.1.5835.5.2.800.1.2ScalarntcAsiInActiveInputread-onlycurrentDisplays the active ASI input interface. When PRBS is selected it will indicate 'off'.
1.3.6.1.4.1.5835.5.2.800.1.3ScalarntcAsiInInlineSplitterread-writecurrentVariable to configure the presence of an external in-line splitter with a given loss.
1.3.6.1.4.1.5835.5.2.800.1.4ScalarntcAsiInMeasuredInputTsBitRateread-onlycurrentDisplays the measured ASI interface input rate in bps.
1.3.6.1.4.1.5835.5.2.800.1.5ScalarntcAsiInInputFramingread-writecurrentConfiguration of the ASI input framing type. - 188-byte packets - 204-byte packets (188 data bytes and 16 dummy bytes). Before transmission, these 16 bytes are…
1.3.6.1.4.1.5835.5.2.800.1.6ScalarntcAsiInInputIfSwitchCountread-onlycurrentCounts the number of times the device switched to another ASI input interface.
1.3.6.1.4.1.5835.5.2.800.1.7IdentityntcAsiInPrbsGeneratorcurrentContainer holding ntcAsiInPrbsGenerator definitions.
1.3.6.1.4.1.5835.5.2.800.1.7.1ScalarntcAsiInPrbsGenTsBitRateread-writecurrentThe PRBS (Pseudo Random Binary Sequence) generator TS Bit Rate in bps.
1.3.6.1.4.1.5835.5.2.800.1.7.2ScalarntcAsiInPrbsGenTyperead-writecurrent- PRBS : Configures the test generator to generate transport stream packets containing PRBS data. The generated PRBS complies with HP3764 Compatible 2^23-1 PRB…
1.3.6.1.4.1.5835.5.2.800.1.7.3ScalarntcAsiInPrbsGenPidHandlingread-writecurrentConfiguration of the PID (Packet Identifier) handling in the PRBS Generator. Configuration of the test generator to generate transport stream packets with a va…
1.3.6.1.4.1.5835.5.2.800.1.7.4ScalarntcAsiInPrbsGenPidValueread-writecurrentConfigure the PRBS generator packet PID value.
1.3.6.1.4.1.5835.5.2.800.1.7.5ScalarntcAsiInPrbsGenNumberDataPktread-writecurrentConfiguration of the number of datapackets per burst. Current devices have an upper limit of 255 datapackets per burst.
1.3.6.1.4.1.5835.5.2.800.1.7.6ScalarntcAsiInPrbsGenNumberNullPktread-writecurrentConfiguration of the number of null packets per burst. Current devices have an upper limit of 255 but this may increase in the future.
1.3.6.1.4.1.5835.5.2.800.1.8IdentityntcAsiInPrbsMonitorcurrentContainer holding ntcAsiInPrbsMonitor definitions.
1.3.6.1.4.1.5835.5.2.800.1.8.1ScalarntcAsiInPrbsMonEnableread-writecurrentEnable or disable the PRBS monitoring. When monitoring is enabled the statistics are displayed in the following parameters.
1.3.6.1.4.1.5835.5.2.800.1.8.2ScalarntcAsiInPrbsMonPidHandlingread-writecurrentDetect/filter out the PID inside data packets of the PRBS monitor. This is reflected in the monitoring statistics.
1.3.6.1.4.1.5835.5.2.800.1.8.3ScalarntcAsiInPrbsMonPidValueread-writecurrentConfiguration of the PRBS monitor data packet PID value.
1.3.6.1.4.1.5835.5.2.800.1.8.4ScalarntcAsiInPrbsMonStateread-onlycurrentDisplays the PRBS monitor status. Possible values are: Off, Unsync (no PRBS sync) and PRBS (PRBS sync).
1.3.6.1.4.1.5835.5.2.800.1.8.5ScalarntcAsiInPrbsMonSyncSecondsread-onlycurrentIndicates how many seconds the PRBS monitor is synchronized to the PRBS stream.
1.3.6.1.4.1.5835.5.2.800.1.8.6ScalarntcAsiInPrbsMonErrorCountread-onlycurrentNumber of errors detected in the PRBS stream.
1.3.6.1.4.1.5835.5.2.800.1.8.7ScalarntcAsiInPrbsMonErrorRateread-onlycurrentError rate detected in the PRBS stream. Float represented as unsigned integer is scaled by a factor of 10. i.e. a value of 100 in SNMP means an error rate of 1…
1.3.6.1.4.1.5835.5.2.800.1.8.8ScalarntcAsiInPrbsMonErrorRatioread-onlycurrentDisplays the error ratio detected in the PRBS stream.
1.3.6.1.4.1.5835.5.2.800.1.9IdentityntcAsiInAlarmcurrentContainer holding ntcAsiInAlarm definitions.
1.3.6.1.4.1.5835.5.2.800.1.9.1ScalarntcAsiInAlmGeneralAsiInputread-onlycurrentThis alarm is raised when there is a general ASI input alarm. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.9.2ScalarntcAsiInAlmNoInputSignalread-onlycurrentThis alarm is raised when no input signal is detected at the selected ASI input. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.9.3ScalarntcAsiInAlmNoInputDataread-onlycurrentThis alarm is raised when no input data is detected at the selected ASI input. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.9.4ScalarntcAsiInAlmInvalidTsBitRateread-onlycurrentThis alarm is raised when the measured input Transport-Stream (TS) bitrate is higher or lower than the expected value. This variable indicates the current stat…
1.3.6.1.4.1.5835.5.2.800.1.9.5ScalarntcAsiInAlmBufferOverflowread-onlycurrentThis alarm is raised when the input data buffer is full. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.9.6ScalarntcAsiInAlmNoInputSignalAsi1read-onlycurrentThis alarm is raised when no input signal is detected at the ASI1 input. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.9.7ScalarntcAsiInAlmNoInputSignalAsi2read-onlycurrentThis alarm is raised when no input signal is detected at the ASI2 input. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.9.8ScalarntcAsiInAlmNoInputDataAsi1read-onlycurrentThis alarm is raised when no input data is detected at the ASI1 input. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.9.9ScalarntcAsiInAlmNoInputDataAsi2read-onlycurrentThis alarm is raised when no input data is detected at the ASI2 input. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.800.1.10ScalarntcAsiInInputTsBitRateread-writecurrentDisplays the ASI interface input rate. Expressed in bps.
1.3.6.1.4.1.5835.5.2.800.1.11IdentityntcAsiInNpRangeThrcurrentContainer holding ntcAsiInNpRangeThr definitions.
1.3.6.1.4.1.5835.5.2.800.1.11.1ScalarntcAsiInNpRangeThrEnableread-writecurrentEnable or disable the Null Packet Rate Threshold.
1.3.6.1.4.1.5835.5.2.800.1.11.2ScalarntcAsiInNpRangeThrMaxRateread-writecurrentMaximum Null Packets Bit Rate.
1.3.6.1.4.1.5835.5.2.800.1.11.3ScalarntcAsiInNpRangeTimeWindowread-writecurrentSpecify the time window in seconds.
1.3.6.1.4.1.5835.5.2.800.2IdentityntcAsiInConformancecurrentConformance requirements.
1.3.6.1.4.1.5835.5.2.800.2.1IdentityntcAsiInConfCompliancecurrentDevice compliance statements.
1.3.6.1.4.1.5835.5.2.800.2.1.1CompliancentcAsiInConfCompV1StandardcurrentCompliance statement for Newtec device MIB implementations.
1.3.6.1.4.1.5835.5.2.800.2.2IdentityntcAsiInConfGroupcurrentGroups used by device compliance statements.
1.3.6.1.4.1.5835.5.2.800.2.2.1GroupntcAsiInConfGrpV1StandardcurrentManaged objects that constitute version 1 of a system device with standard capabilities.