MIB Viewer

NEWTEC-AUPCCONTROLLER-MIB

19 objects
Newtec modular AUPC controller MIB containing definitions for the AUPC controller.
Imported Objects
NEWTEC-MAIN-MIBntcFunction
NEWTEC-TC-MIBNtcEnable
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter64 Integer32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.5835.5.2.4200IdentityntcAupcControllerNewtec modular AUPC controller MIB containing definitions for the AUPC controller.
1.3.6.1.4.1.5835.5.2.4200.1IdentityntcAupcCtrlObjectscurrentContainer holding ntcAupcCtrlObjects definitions.
1.3.6.1.4.1.5835.5.2.4200.1.1ScalarntcAupcCtrlEnableread-writecurrentEnable or disable the AUPC controller
1.3.6.1.4.1.5835.5.2.4200.1.2ScalarntcAupcCtrlNominalModPowerread-writecurrentNominal modulator output power setting in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103'…
1.3.6.1.4.1.5835.5.2.4200.1.3ScalarntcAupcCtrlMaximumModPowerread-writecurrentMaximum modulator output power setting in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103'…
1.3.6.1.4.1.5835.5.2.4200.1.4ScalarntcAupcCtrlMaximumPowerStepUpread-writecurrentMaximum step size by which the modulator power level is raised per second Float represented as integer is scaled by a factor of 10. i.e. a value of '10' means …
1.3.6.1.4.1.5835.5.2.4200.1.5ScalarntcAupcCtrlMaximumPowerStepDownread-writecurrentMaximum step size by which the modulator power level is decreased per second Float represented as integer is scaled by a factor of 10. i.e. a value of '10' mea…
1.3.6.1.4.1.5835.5.2.4200.1.6ScalarntcAupcCtrlRefTermread-writecurrentThe reference terminal that feeds the AUPC algorithm. Terminal '0' indicates that the input of every terminal can be used.
1.3.6.1.4.1.5835.5.2.4200.1.7IdentityntcAupcCtrlMonitoringcurrentContainer holding ntcAupcCtrlMonitoring definitions.
1.3.6.1.4.1.5835.5.2.4200.1.7.1ScalarntcAupcCtrlForwardConfigCounterread-onlycurrentThe number of forward configuration messages
1.3.6.1.4.1.5835.5.2.4200.1.7.2ScalarntcAupcCtrlClientFeedbackCounterread-onlycurrentThe number of client feedback messages received
1.3.6.1.4.1.5835.5.2.4200.1.7.3ScalarntcAupcCtrlPowerRequestCounterread-onlycurrentThe number of power updates
1.3.6.1.4.1.5835.5.2.4200.1.7.4ScalarntcAupcCtrlReqModulatorPowerread-onlycurrentThe requested modulator power in dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '-10.3' dBm Note that the range no…
1.3.6.1.4.1.5835.5.2.4200.1.7.5ScalarntcAupcCtrlCurModulatorPowerread-onlycurrentThe current modulator power in dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '-10.3' dBm Note that the range norm…
1.3.6.1.4.1.5835.5.2.4200.2IdentityntcAupcCtrlConformancecurrentConformance requirements.
1.3.6.1.4.1.5835.5.2.4200.2.1IdentityntcAupcCtrlConfCompliancecurrentDevice compliance statements.
1.3.6.1.4.1.5835.5.2.4200.2.1.1CompliancentcAupcCtrlConfCompV1StandardcurrentCompliance statement for Newtec device MIB implementations.
1.3.6.1.4.1.5835.5.2.4200.2.2IdentityntcAupcCtrlConfGroupcurrentGroups used by device compliance statements.
1.3.6.1.4.1.5835.5.2.4200.2.2.1GroupntcAupcCtrlConfGrpV1StandardcurrentManaged objects that constitute version 1 of a system device with standard capabilities.