MIB Viewer

NEWTEC-BBFOVERIPIN-MIB

60 objects
Newtec modular BBFoverIP input MIB containing definitions for DVB-S2 BaseBand Frames over IP input functionality.
Imported Objects
NEWTEC-MAIN-MIBntcFunction
NEWTEC-TC-MIBNtcAlarmState NtcEnable
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 IpAddress MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString RowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.5835.5.2.1200IdentityntcBbfOverIpInNewtec modular BBFoverIP input MIB containing definitions for DVB-S2 BaseBand Frames over IP input functionality.
1.3.6.1.4.1.5835.5.2.1200.1IdentityntcBbfOIpInObjectscurrentContainer holding ntcBbfOIpInObjects definitions.
1.3.6.1.4.1.5835.5.2.1200.1.1ScalarntcBbfOIpInEnableread-writecurrentEnable or disable BBF over IP reception.
1.3.6.1.4.1.5835.5.2.1200.1.2ScalarntcBbfOIpInInputSelectionread-writecurrentConfigures the input interface for the BBF over IP functionality.
1.3.6.1.4.1.5835.5.2.1200.1.3TablentcConfigurationTableTablenot-accessiblecurrentConfiguration table
1.3.6.1.4.1.5835.5.2.1200.1.3.1RowntcConfigurationTableEntrynot-accessiblecurrentA conceptual row of the ntcConfigurationTableTable.
1.3.6.1.4.1.5835.5.2.1200.1.3.1.1ColumnntcConfigurationTableNamenot-accessiblecurrentName of the configuration
1.3.6.1.4.1.5835.5.2.1200.1.3.1.2ColumnntcConfigurationTableRowStatusread-createcurrentThe status of this conceptual row. An existing conceptual row can be in any one of the three states, 'notReady', 'notInService', or 'active'. If the manager wi…
1.3.6.1.4.1.5835.5.2.1200.1.3.1.3ColumnntcBbfOIpInEpEnableread-createcurrentEnable or disable a BBF endpoint.
1.3.6.1.4.1.5835.5.2.1200.1.3.1.4ColumnntcBbfOIpInIpEpAddressTyperead-createcurrentConfiguration of the IP address type for BBF over IP reception. (unicast or multicast)
1.3.6.1.4.1.5835.5.2.1200.1.3.1.5ColumnntcBbfOIpInEpMulticastAddressread-createcurrentMulticast IP address used to receive the BBF over IP data. Regular expression : (?-mix:^\d{1,3}\.\d{1,3}\.\d{1,3}\.\d{1,3}$)
1.3.6.1.4.1.5835.5.2.1200.1.3.1.6ColumnntcBbfOIpInEpIpUdpPortread-createcurrentConfiguration of the UDP port on which the BBF over IP is received
1.3.6.1.4.1.5835.5.2.1200.1.3.1.7ColumnntcBbfOIpInEpBbfTyperead-createcurrentType of baseband frames which are received in the BBF over IP functionality.
1.3.6.1.4.1.5835.5.2.1200.1.3.1.8ColumnntcBbfOIpInEpSourceRedundancyread-createcurrentEnable or disable source redundancy.
1.3.6.1.4.1.5835.5.2.1200.1.4IdentityntcBbfOIpInMonitorcurrentContainer holding ntcBbfOIpInMonitor definitions.
1.3.6.1.4.1.5835.5.2.1200.1.4.1ScalarntcBbfOIpInMonCounterResetread-writecurrentReset the BBF over IP traffic and monitor counters.
1.3.6.1.4.1.5835.5.2.1200.1.4.2ScalarntcBbfOIpInMonBbfInputBitRateTread-onlycurrentTotal BBF over IP input bit rate in bps.
1.3.6.1.4.1.5835.5.2.1200.1.4.3ScalarntcBbfOIpInMonBbfInCountTread-onlycurrentNumber of received BBFs.
1.3.6.1.4.1.5835.5.2.1200.1.4.4ScalarntcBbfOIpInMonBbfOutCountTread-onlycurrentTotal number of transmitted BBFs.
1.3.6.1.4.1.5835.5.2.1200.1.4.5ScalarntcBbfOIpInMonBbfDropCountTread-onlycurrentTotal number of dropped BBFs.
1.3.6.1.4.1.5835.5.2.1200.1.4.6ScalarntcBbfOIpInMonBbfOverflowCountTread-onlycurrentTotal number of BBFs that are dropped because the input data buffer is full.
1.3.6.1.4.1.5835.5.2.1200.1.4.7ScalarntcBbfOIpInMonBbfByteOutCountTread-onlycurrentThis parameter counts the total number of Baseband Frame bytes properly transmitted
1.3.6.1.4.1.5835.5.2.1200.1.4.8ScalarntcBbfOIpInMonBbfInvFrameCountTread-onlycurrentTotal number of BBFs that are dropped because the received modulation type is not active on the device.
1.3.6.1.4.1.5835.5.2.1200.1.4.9ScalarntcBbfOIpInMonBbfDiscontCountTread-onlycurrentTotal number of discontinuity counts over all BBF streams.
1.3.6.1.4.1.5835.5.2.1200.1.4.10ScalarntcBbfOIpInMonBbfModcodNSCountTread-onlycurrentTotal number of BBFs which are dropped because the received modcod is not licensed.
1.3.6.1.4.1.5835.5.2.1200.1.4.11TablentcMonitoringTableTablenot-accessiblecurrentMonitoring table
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1RowntcMonitoringTableEntrynot-accessiblecurrentA conceptual row of the ntcMonitoringTableTable.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.1ColumnntcMonitoringTableNamenot-accessiblecurrentName of the output monitor
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.2ColumnntcBbfOIpInMonBbfInputBitRateread-onlycurrentBBF over IP input bit rate in bps.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.3ColumnntcBbfOIpInMonSourceAddressread-onlycurrentSource sending the traffic
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.4ColumnntcBbfOIpInMonBbfInCountread-onlycurrentNumber of received BBFs.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.5ColumnntcBbfOIpInMonBbfOutCountread-onlycurrentNumber of transmitted BBFs.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.6ColumnntcBbfOIpInMonBbfByteOutCountread-onlycurrentThis parameter counts the number of Baseband Frame bytes properly transmitted in a stream.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.7ColumnntcBbfOIpInMonBbfDropCountread-onlycurrentNumber of dropped BBFs.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.8ColumnntcBbfOIpInMonBbfOverflowCountread-onlycurrentNumber of BBFs that are dropped for a specific BBF stream because the input data buffer is full.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.9ColumnntcBbfOIpInMonBbfInvFrameCountread-onlycurrentNumber of BBFs that are dropped because the received modulation type is not active on the device.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.10ColumnntcBbfOIpInMonBbfDiscontCountread-onlycurrentWhen the sequence numbers are not continuous for a certain BBF stream this counter will be incremented.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.11ColumnntcBbfOIpInMonBbfModNSread-onlycurrentNumber of BBFs which are dropped because the received modcod is not licensed for a specified BBF stream.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.12ColumnntcBbfOIpInMonBbfByteCorCountread-onlycurrentThis parameter counts the number of corrupted Baseband Frame bytes that are dropped for a certain BBF stream.
1.3.6.1.4.1.5835.5.2.1200.1.4.11.1.13ColumnntcBbfOIpInMonBbfInvSignCountread-onlycurrentThis parameter counts the number of invalid Tellitec Signalling Frames that are dropped for a certain BBF stream.
1.3.6.1.4.1.5835.5.2.1200.1.4.12TablentcAlarmStatusTableTablenot-accessiblecurrentAlarm status table
1.3.6.1.4.1.5835.5.2.1200.1.4.12.1RowntcAlarmStatusTableEntrynot-accessiblecurrentA conceptual row of the ntcAlarmStatusTableTable.
1.3.6.1.4.1.5835.5.2.1200.1.4.12.1.1ColumnntcStreamInxnot-accessiblecurrentName of the alarm monitor
1.3.6.1.4.1.5835.5.2.1200.1.4.12.1.2ColumnntcBbfOIpInMonBbfNoInpDataErrorread-onlycurrentThis alarm is raised when no input data is received between a 1 second time interval for 1 or more BBF streams. This variable indicates the current status of t…
1.3.6.1.4.1.5835.5.2.1200.1.4.12.1.3ColumnntcBbfOverflowErrorread-onlycurrentThis alarm is raised when the input data buffer for 1 or more BBF streams is full. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1200.1.4.12.1.4ColumnntcBbfDiscontinuityErrorread-onlycurrentThe alarm is raised when the sequence numbers are not continuous for a specific ntS2BBF input stream for 5 sec. This variable indicates the current status of t…
1.3.6.1.4.1.5835.5.2.1200.1.4.12.1.5ColumnntcBbfModcodNotSupportedErrorread-onlycurrentThis alarm is raised when Baseband frames are dropped due to receiving a non licensed modcod. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1200.1.4.13ScalarntcBbfOIpInMonBbfByteCorCountTread-onlycurrentTotal number of corrupted Baseband Frame bytes that are dropped for all BBF streams.
1.3.6.1.4.1.5835.5.2.1200.1.4.14ScalarntcBbfOIpInMonBbfInvSignCountTread-onlycurrentTotal number of invalid Tellitec Signalling Frames that are dropped for all BBF streams.
1.3.6.1.4.1.5835.5.2.1200.1.5IdentityntcBbfOIpInAlarmcurrentContainer holding ntcBbfOIpInAlarm definitions.
1.3.6.1.4.1.5835.5.2.1200.1.5.1ScalarntcBbfOIpInAlmGeneralBbfOverIpInread-onlycurrentThis alarm is raised when there is a general BBF over IP Input alarm. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1200.1.5.2ScalarntcBbfOIpInAlmNoInputDataread-onlycurrentThis alarm is raised when no input data is received between a 1 second time interval for 1 or more BBF streams. This variable indicates the current status of t…
1.3.6.1.4.1.5835.5.2.1200.1.5.3ScalarntcBbfOIpInAlmBufferOverflowread-onlycurrentThis alarm is raised when the input data buffer for 1 or more BBF streams is full. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1200.1.5.4ScalarntcBbfOIpInAlBbfOverIPDiscontread-onlycurrentThe alarm is raised when the sequence numbers are not continuous for a specific ntS2BBF input stream for 5 sec. This variable indicates the current status of t…
1.3.6.1.4.1.5835.5.2.1200.1.5.5ScalarntcBbfOIpInAlBbfOverIPModNSread-onlycurrentThis alarm is raised when Baseband frames are dropped due to receiving a non licensed modcod. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1200.2IdentityntcBbfOIpInConformancecurrentConformance requirements.
1.3.6.1.4.1.5835.5.2.1200.2.1IdentityntcBbfOIpInConfCompliancecurrentDevice compliance statements.
1.3.6.1.4.1.5835.5.2.1200.2.1.1CompliancentcBbfOIpInConfCompV1StandardcurrentCompliance statement for Newtec device MIB implementations.
1.3.6.1.4.1.5835.5.2.1200.2.2IdentityntcBbfOIpInConfGroupcurrentGroups used by device compliance statements.
1.3.6.1.4.1.5835.5.2.1200.2.2.1GroupntcBbfOIpInConfGrpV1StandardcurrentManaged objects that constitute version 1 of a system device with standard capabilities.