MIB Viewer

NEWTEC-CONFIG-MIB

18 objects
Newtec modular MIB containing variables for the management of device configurations. These variables support functionality related to configuration lifecycle and usage.
Imported Objects
NEWTEC-MAIN-MIBntcFunction
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.5835.5.2.1500IdentityntcConfigNewtec modular MIB containing variables for the management of device configurations. These variables support functionality related to configuration lifecycle a…
1.3.6.1.4.1.5835.5.2.1500.1IdentityntcCfgObjectscurrentContainer holding ntcCfgObjects definitions.
1.3.6.1.4.1.5835.5.2.1500.1.1TablentcCfgConfigTablenot-accessiblecurrentThis table contains the names of all persistent stored configuration files.
1.3.6.1.4.1.5835.5.2.1500.1.1.1RowntcCfgConfigEntrynot-accessiblecurrentA conceptual row of the ntcCfgConfigTable.
1.3.6.1.4.1.5835.5.2.1500.1.1.1.1ColumnntcCfgConfigIndexnot-accessiblecurrentA unique key, greater than zero, for each configuration.
1.3.6.1.4.1.5835.5.2.1500.1.1.1.2ColumnntcCfgConfigNameread-onlycurrentThe name of an existing configuration.
1.3.6.1.4.1.5835.5.2.1500.1.2ScalarntcCfgActiveConfigread-onlycurrentThe name of the configuration that is currently active. It may contain unsaved changes that were made after initial loading. When saved, the name will change t…
1.3.6.1.4.1.5835.5.2.1500.1.3ScalarntcCfgUnsavedChangesread-onlycurrentA boolean (flag) indicating the presence of unsaved changes in the current configuration. When 'false', all changes have been saved.
1.3.6.1.4.1.5835.5.2.1500.1.4ScalarntcCfgBootConfigread-writecurrentThe name of the configuration that will be loaded when the device is going through its next boot sequence. Can be set to select a different available configura…
1.3.6.1.4.1.5835.5.2.1500.1.5ScalarntcCfgLoadConfigread-writecurrentA command that loads the configuration with the specified name. Reading this variable will always return an empty string.
1.3.6.1.4.1.5835.5.2.1500.1.6ScalarntcCfgSaveConfigread-writecurrentA command that saves the active configuration with the name specified. Reading this variable will always return an empty string.
1.3.6.1.4.1.5835.5.2.1500.1.7ScalarntcCfgDeleteConfigread-writecurrentA command that deletes the configuration with the specified name. Reading this variable will always return an empty string.
1.3.6.1.4.1.5835.5.2.1500.1.8ScalarntcCfgLoadConfigNotForcedread-writecurrentA command that loads the configuration with the specified name in a not forced way. Reading this variable will always return an empty string.
1.3.6.1.4.1.5835.5.2.1500.2IdentityntcCfgConformancecurrentConformance requirements.
1.3.6.1.4.1.5835.5.2.1500.2.1IdentityntcCfgConfCompliancecurrentDevice compliance statements.
1.3.6.1.4.1.5835.5.2.1500.2.1.1CompliancentcCfgConfCompV1StandardcurrentCompliance statement for Newtec device MIB implementations.
1.3.6.1.4.1.5835.5.2.1500.2.2IdentityntcCfgConfGroupcurrentGroups used by device compliance statements.
1.3.6.1.4.1.5835.5.2.1500.2.2.1GroupntcCfgConfGrpV1StandardcurrentManaged objects that constitute version 1 of a system device with standard capabilities.