Newtec modular DVB modulator MIB containing definitions for DVB-S and DVB-S2 modulator functionality.
Imported Objects
FLOAT-TC-MIB MISSINGFloat32TC
NEWTEC-MAIN-MIBntcFunction
NEWTEC-TC-MIBNtcAlarmState NtcEnable
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Integer32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.5835.5.2.1000IdentityntcDvbModulatorNewtec modular DVB modulator MIB containing definitions for DVB-S and DVB-S2 modulator functionality.
1.3.6.1.4.1.5835.5.2.1000.1IdentityntcDvbModObjectscurrentContainer holding ntcDvbModObjects definitions.
1.3.6.1.4.1.5835.5.2.1000.1.1ScalarntcDvbModModeread-writecurrentThe modulation standard defines the operating mode of the modulator. - DVB-S2 : compatible with EN302307. Single Stream Transport Stream Broadcasting Applicati…
1.3.6.1.4.1.5835.5.2.1000.1.2ScalarntcDvbModTransmitread-writecurrentEnable or disable the modulator output transmit signal. When it is enabled the actual output can still be switched-off upon detection of e.g. general device al…
1.3.6.1.4.1.5835.5.2.1000.1.3ScalarntcDvbModTransmitStateread-onlycurrentCurrent transmit status of the modulator (on or off). The actual transmit status is determined by the transmit configuration parameter and by other events. Not…
1.3.6.1.4.1.5835.5.2.1000.1.4ScalarntcDvbModTxCtrlGenDeviceAlarmread-writecurrentConfigure the impact of a General Device alarm on the Modulator Transmit.
1.3.6.1.4.1.5835.5.2.1000.1.5ScalarntcDvbModTxCtrlGenInterfaceAlarmread-writecurrentConfigure the impact of a General Interface Alarm on the Modulator Transmit
1.3.6.1.4.1.5835.5.2.1000.1.6ScalarntcDvbModOutputFrequencyread-writecurrentModulator output frequency setting. Current devices support a frequency range of 50..180 Mhz or 960..2150 MHz.
1.3.6.1.4.1.5835.5.2.1000.1.7ScalarntcDvbModRollOffread-writecurrentThe transmit filter Roll-off factor setting determines the output spectrum excess bandwidth by controlling the RCRO (Root Cosine Roll-off) factor of the matche…
1.3.6.1.4.1.5835.5.2.1000.1.8ScalarntcDvbModOccupiedBandWidthread-onlycurrentThe '-26 dB' bandwidth of the signal. This is calculated as the symbol rate multiplied with (1 + a) with a = the selected roll-off factor.
1.3.6.1.4.1.5835.5.2.1000.1.9ScalarntcDvbModOutputBandread-onlycurrentIndicates the used output frequency band: IF band or L band.
1.3.6.1.4.1.5835.5.2.1000.1.10ScalarntcDvbModSpectrumPolarityread-writecurrentTransmit spectrum polarity selection. The spectrum at IFL and at RF is coupled by the installed upconverter module. This can be deduced from the frequency conv…
1.3.6.1.4.1.5835.5.2.1000.1.11ScalarntcDvbModOutputLevelread-writecurrentModulator output level setting in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '…
1.3.6.1.4.1.5835.5.2.1000.1.12ScalarntcDvbModClockOutputread-writecurrentEnables or disables the transmission of a 10MHz clock signal on the RF output cable.
1.3.6.1.4.1.5835.5.2.1000.1.13ScalarntcDvbModCarrierModulationread-writecurrentCarrier modulation selection : - modulation on: Operational modulated carrier signal - pure carrier: unmodulated output signal - 'test modulation CLK/n': Carri…
1.3.6.1.4.1.5835.5.2.1000.1.14ScalarntcDvbModAmplSlopeEqualizerread-writecurrentConfiguration of the amplitude slope equalizer. An amplitude slope in the up-converter or in the high power amplifier can be compensated by using this equalize…
1.3.6.1.4.1.5835.5.2.1000.1.15IdentityntcDvbModDvbs2AcmcurrentContainer holding ntcDvbModDvbs2Acm definitions.
1.3.6.1.4.1.5835.5.2.1000.1.15.1ScalarntcDvbModDvbs2AcmSymbolRateread-writedeprecatedDefine the required symbol rate in baud.
1.3.6.1.4.1.5835.5.2.1000.1.16IdentityntcDvbModDvbs2currentContainer holding ntcDvbModDvbs2 definitions.
1.3.6.1.4.1.5835.5.2.1000.1.16.1ScalarntcDvbModDvbs2Isiread-writedeprecatedThe DVB-S2 Input Stream Identifier (ISI) is present in the second byte position of the MATYPE field in the baseband header of a DVB-S2 baseband frame. It is a …
1.3.6.1.4.1.5835.5.2.1000.1.16.2ScalarntcDvbModDvbs2FrameTyperead-writecurrentDvb-S2 defines 2 FEC-frame types : - normal: FECframes of 64800 bits or 8100 bytes - short: FECframes of 16200 bits or 2025 bytes Short frames are used when wo…
1.3.6.1.4.1.5835.5.2.1000.1.16.3ScalarntcDvbModDvbs2ModCodread-writecurrentThe selection of modulation type and the FEC rate.
1.3.6.1.4.1.5835.5.2.1000.1.16.4ScalarntcDvbModDvbs2Pilotsread-writecurrentDvb-S2 Physical Layer Pilot insertion. When enabled, every 16 slots (of 90 symbols) the modulator will insert 36 unmodulated symbols to aid in receiver synchro…
1.3.6.1.4.1.5835.5.2.1000.1.16.5ScalarntcDvbModDvbs2RatePriorityread-writedeprecatedSelect the rate mode (symbol rate or bit rate). The selected rate will be kept constant when other parameters have impact a the modulator rate. Only the select…
1.3.6.1.4.1.5835.5.2.1000.1.16.6ScalarntcDvbModDvbs2SymbolRateread-writedeprecatedDefine the required symbol rate in baud.
1.3.6.1.4.1.5835.5.2.1000.1.16.7ScalarntcDvbModDvbs2BitRateread-writedeprecatedDefine the required bit rate of the modulator. Current devices support a range of 50000 to 250000000 bps.
1.3.6.1.4.1.5835.5.2.1000.1.16.8ScalarntcDvbModDvbs2MeasuredPktCountread-onlydeprecatedMeasured TS packet count of the modulator.
1.3.6.1.4.1.5835.5.2.1000.1.16.9ScalarntcDvbModDvbs2MeasuredBitRateread-onlydeprecatedMeasured bitrate of the modulator.
1.3.6.1.4.1.5835.5.2.1000.1.16.10ScalarntcDvbModDvbs2PhyLayerEfficiencyread-onlycurrentThe measured physical layer efficiency, equal to the percentage of non-dummy physical layer frames. Float represented as integer is scaled by a factor of 100. …
1.3.6.1.4.1.5835.5.2.1000.1.16.11ScalarntcDvbModDvbs2BbLayerEfficiencyread-onlycurrentThe measured baseband layer efficiency, equal to the percentage user data in tbe baseband frames. Float represented as integer is scaled by a factor of 100. i.…
1.3.6.1.4.1.5835.5.2.1000.1.16.12ScalarntcDvbModDvbs2DumPlScramblModeread-writecurrentThe dummy physical layer scrambler mode can be set to continuous, to achieve more randomness in the carrier data as required for bandwidth cancellation.
1.3.6.1.4.1.5835.5.2.1000.1.16.13ScalarntcDvbModDvbs2PlScrambSigread-writecurrentThe physical layer scrambler signature.
1.3.6.1.4.1.5835.5.2.1000.1.16.14ScalarntcDvbModDvbs2Resetread-writedeprecatedReset the modulator monitoring counters.
1.3.6.1.4.1.5835.5.2.1000.1.16.15ScalarntcDvbModDvbs2RollOffSignallingread-writecurrentWhen a Roll-off <20% is configured, this setting is used to put the Roll-off bits in the baseband header to reserved (11) or to a standardized value. Some rece…
1.3.6.1.4.1.5835.5.2.1000.1.17IdentityntcDvbModDvbscurrentContainer holding ntcDvbModDvbs definitions.
1.3.6.1.4.1.5835.5.2.1000.1.17.1ScalarntcDvbModDvbsModCodread-writecurrentThe selection of the FEC code-rate and modulation scheme supported by DVB-S
1.3.6.1.4.1.5835.5.2.1000.1.17.2ScalarntcDvbModDvbsRatePriorityread-writedeprecatedSelect the rate mode (symbol rate or bit rate). The selected rate will be kept constant when other parameters have impact a the modulator rate. Only the select…
1.3.6.1.4.1.5835.5.2.1000.1.17.3ScalarntcDvbModDvbsSymbolRateread-writedeprecatedDefine the required symbol rate in baud.
1.3.6.1.4.1.5835.5.2.1000.1.17.4ScalarntcDvbModDvbsBitRateread-writedeprecatedDefine the required bit rate of the modulator. Current devices support a range of 50000 to 250000000 bps.
1.3.6.1.4.1.5835.5.2.1000.1.17.5ScalarntcDvbModDvbsMeasuredPktCountread-onlydeprecatedMeasured TS packet count of the modulator.
1.3.6.1.4.1.5835.5.2.1000.1.17.6ScalarntcDvbModDvbsMeasuredBitRateread-onlydeprecatedMeasured bitrate of the modulator.
1.3.6.1.4.1.5835.5.2.1000.1.17.7ScalarntcDvbModDvbsResetread-writedeprecatedReset the modulator monitoring counters.
1.3.6.1.4.1.5835.5.2.1000.1.18IdentityntcDvbModEqualinkcurrentContainer holding ntcDvbModEqualink definitions.
1.3.6.1.4.1.5835.5.2.1000.1.18.1IdentityntcDvbModEqlnkLinearcurrentContainer holding ntcDvbModEqlnkLinear definitions.
1.3.6.1.4.1.5835.5.2.1000.1.18.1.1ScalarntcDvbModEqlnkLinModeread-writecurrentEnable or disable linear equalink. Enable this component to compensate amplitude distorions and group delay distortions. This improves the transponder throughp…
1.3.6.1.4.1.5835.5.2.1000.1.18.1.2ScalarntcDvbModEqlnkLinStateread-onlycurrentDisplays the current linear predistortion status. The actual linear predistortion status is determined by the configuration parameter but is also automatically…
1.3.6.1.4.1.5835.5.2.1000.1.18.1.3ScalarntcDvbModEqlnkLinInforead-onlycurrentDetailed info for linear equalink.
1.3.6.1.4.1.5835.5.2.1000.1.18.1.4IdentityntcDvbModEqlnkLinConfcurrentContainer holding ntcDvbModEqlnkLinConf definitions.
1.3.6.1.4.1.5835.5.2.1000.1.18.1.4.1IdentityntcDvbModEqlnkLinAppcurrentContainer holding ntcDvbModEqlnkLinApp definitions.
1.3.6.1.4.1.5835.5.2.1000.1.18.1.4.1.1ScalarntcDvbModEqlnkLinAppOutFreqread-writecurrentModulator output frequency that was used during the calibration.
1.3.6.1.4.1.5835.5.2.1000.1.18.1.4.1.2ScalarntcDvbModEqlnkLinAppRollOffread-writecurrentThe transmit filter roll-off factor setting determines the output spectrum excess bandwidth by controlling the RCRO (Root Cosine Roll-Off) factor of the matche…
1.3.6.1.4.1.5835.5.2.1000.1.18.1.4.1.3ScalarntcDvbModEqlnkLinAppSymRateread-writecurrentThe Symbol Rate that was used during the calibration.
1.3.6.1.4.1.5835.5.2.1000.1.18.2IdentityntcDvbModEqlnkNonlinearcurrentContainer holding ntcDvbModEqlnkNonlinear definitions.
1.3.6.1.4.1.5835.5.2.1000.1.18.2.1ScalarntcDvbModEqlnkNonlinModeread-writecurrentEnable or disable non-linear equalink. Non-linear distortion is typically caused by non-linearity in the amplifier of the satellite. Enable this parameter to c…
1.3.6.1.4.1.5835.5.2.1000.1.18.2.2ScalarntcDvbModEqlnkNonlinStateread-onlycurrentDisplays the current non-linear predistortion status. The actual non-linear predistortion status is determined by the configuration parameter but is also autom…
1.3.6.1.4.1.5835.5.2.1000.1.18.2.3ScalarntcDvbModEqlnkNonlinInforead-onlycurrentDetailed info for non-linear equalink
1.3.6.1.4.1.5835.5.2.1000.1.18.2.4IdentityntcDvbModEqlnkNonlinConfcurrentContainer holding ntcDvbModEqlnkNonlinConf definitions.
1.3.6.1.4.1.5835.5.2.1000.1.18.2.4.1IdentityntcDvbModEqlnkNonlinAppcurrentContainer holding ntcDvbModEqlnkNonlinApp definitions.
1.3.6.1.4.1.5835.5.2.1000.1.18.2.4.1.1ScalarntcDvbModEqlnkNonlinAppOutFreqread-writecurrentModulator output frequency that was used during the calibration.
1.3.6.1.4.1.5835.5.2.1000.1.18.2.4.1.2ScalarntcDvbModEqlnkNonlinAppVersionread-writecurrentEqualink version that was used during calibration
1.3.6.1.4.1.5835.5.2.1000.1.19IdentityntcDvbModAlarmcurrentContainer holding ntcDvbModAlarm definitions.
1.3.6.1.4.1.5835.5.2.1000.1.19.1ScalarntcDvbModAlmGeneralModulatorread-onlycurrentThis alarm is raised when there is a general modulator alarm. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.2ScalarntcDvbModAlmNoInputSignalread-onlycurrentThis alarm is raised when no input signal is detected at the input of the modulator. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.3ScalarntcDvbModAlmBufferUnderflowread-onlycurrentThis alarm is raised when the input data buffer to the modulator is empty. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.4ScalarntcDvbModAlmBufferOverflowread-onlycurrentThis alarm is raised when the input data buffer of the modulator is full. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.5ScalarntcDvbModAlmNoInputFrameSyncread-onlycurrentThis alarm indicates loss of input framing on the incoming data of the modulator. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.6ScalarntcDvbModAlmNoBaseBandFrameSyncread-onlycurrentThis alarm indicates synchronization loss of the baseband framer on the incoming data. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.7ScalarntcDvbModAlmNoPhyLayerFrameSyncread-onlycurrentThis alarm indicates loss of synchronization between the physical layer framing and the baseband frames. This variable indicates the current status of the alar…
1.3.6.1.4.1.5835.5.2.1000.1.19.8ScalarntcDvbModAlmSynthFailread-onlycurrentThis alarm is raised when there is a failure with a synthesizer. It indicates a malfunction of the synthesizer hardware which generates the IFL carrier frequen…
1.3.6.1.4.1.5835.5.2.1000.1.19.9ScalarntcDvbModAlmRefSynthOutOfLockread-onlycurrentThis alarm is raised when the reference synthesizer is out of lock. It indicates a malfunction of the reference synthesizer hardware which generates the IFL ca…
1.3.6.1.4.1.5835.5.2.1000.1.19.10ScalarntcDvbModAlmLo1SynthOutOfLockread-onlycurrentThis alarm is raised when the synthesizer of the first Local Oscillator is out of lock. It indicates a malfunction of the synthesizer hardware which generates …
1.3.6.1.4.1.5835.5.2.1000.1.19.11ScalarntcDvbModAlmLo2SynthOutOfLockread-onlycurrentThis alarm is raised when the synthesizer of the second Local Oscillator is out of lock. It indicates a malfunction of the synthesizer hardware which generates…
1.3.6.1.4.1.5835.5.2.1000.1.19.12ScalarntcDvbModAlmNoCalibrationDataread-onlycurrentThis alarm is raised when there is no Calibration data available for the modulator. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.13ScalarntcDvbModAlmDacFailureread-onlycurrentThis alarm is raised when there is a general DAC Failure. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.14ScalarntcDvbModAlmBucPowerMinCurrentread-onlycurrentThis alarm is raised when measured current for block up converter power is below specified minimal value. This variable indicates the current status of the ala…
1.3.6.1.4.1.5835.5.2.1000.1.19.15ScalarntcDvbModAlmBucPowerOverloadread-onlycurrentThis alarm is raised when overload is detected. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.16ScalarntcDvbModAlmBucPowerSupplyread-onlycurrentThis alarm is raised when 24V/48V supply is not operational This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.17ScalarntcDvbModAlmBucPowerCapread-onlycurrentThis alarm is raised when there is too much output capacitance connected. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.18ScalarntcDvbModAlmBucPowerShortCircuitread-onlycurrentThis alarm is raised when short circuit is detected. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.19.19ScalarntcDvbModAlmBucPowerHardwareread-onlycurrentThis alarm is raised when communication with block up converter power unit is lost. This variable indicates the current status of the alarm.
1.3.6.1.4.1.5835.5.2.1000.1.20ScalarntcDvbModInputTyperead-writecurrentThe type of input packets or frames for the modulator.
1.3.6.1.4.1.5835.5.2.1000.1.21IdentityntcDvbModRfCidcurrentContainer holding ntcDvbModRfCid definitions.
1.3.6.1.4.1.5835.5.2.1000.1.21.1ScalarntcDvbModRfCidEnableread-writecurrentEnable or disable the RF Carrier ID insertion.
1.3.6.1.4.1.5835.5.2.1000.1.21.2ScalarntcDvbModRfCidIdread-onlycurrentThe 64-bit DVB CID Global Unique Identifier is based on the IEEE EUI-64 derived from a 48 bit MAC address of the management interface.
1.3.6.1.4.1.5835.5.2.1000.1.21.3ScalarntcDvbModRfCidFormatread-onlycurrentRevision code anticipating possible changes in the number and possible content of the fields.
1.3.6.1.4.1.5835.5.2.1000.1.21.4ScalarntcDvbModRfCidSendGeoCordread-writecurrentEnable or disable sending geo coordinates (longitude/latitude) in a DVB-CID message.
1.3.6.1.4.1.5835.5.2.1000.1.21.5ScalarntcDvbModRfCidLatituderead-writecurrentGeo coordinates of modulator in degrees (latitude from +00.0000 to +/-90.0000)
1.3.6.1.4.1.5835.5.2.1000.1.21.6ScalarntcDvbModRfCidLongituderead-writecurrentGeo coordinates of modulator in degrees (longitude from +000.0000 to +/-180.0000)
1.3.6.1.4.1.5835.5.2.1000.1.21.7ScalarntcDvbModRfCidPhoneread-writecurrentOperators telephone number (for example +323 780 65 00 ext. 0) Regular expression : (?-mix:(\+?[ \d]+(ext\.)?[ \d]*)?)
1.3.6.1.4.1.5835.5.2.1000.1.21.8ScalarntcDvbModRfCidDataread-writecurrentCustom user data (up to 24 ASCII chars)
1.3.6.1.4.1.5835.5.2.1000.1.21.9ScalarntcDvbModRfCidLatitudeStringread-writecurrentGeo coordinates of modulator in degrees (latitude from +00.0000 to +/-90.0000)
1.3.6.1.4.1.5835.5.2.1000.1.21.10ScalarntcDvbModRfCidLongitudeStringread-writecurrentGeo coordinates of modulator in degrees (longitude from +000.0000 to +/-180.0000)
1.3.6.1.4.1.5835.5.2.1000.1.22IdentityntcDvbModDcBuccurrentContainer holding ntcDvbModDcBuc definitions.
1.3.6.1.4.1.5835.5.2.1000.1.22.1ScalarntcDvbModDcBucEnableread-writecurrentEnable or disable block up converter power.
1.3.6.1.4.1.5835.5.2.1000.1.22.2ScalarntcDvbModDcBucVoltageread-writecurrentSelect block up converter power voltage.
1.3.6.1.4.1.5835.5.2.1000.1.22.3ScalarntcDvbModDcBucOutVoltageread-onlycurrentBlock up converter power measured output voltage.
1.3.6.1.4.1.5835.5.2.1000.1.22.4ScalarntcDvbModDcBucOutCurrentread-onlycurrentBlock up converter power measured output current.
1.3.6.1.4.1.5835.5.2.1000.1.22.5ScalarntcDvbModDcBucMinCurrentread-writecurrentMinimal value for operational block up converter power current. If measured value drops below this value alarm will be raised.
1.3.6.1.4.1.5835.5.2.1000.1.23ScalarntcDvbModRatePriorityread-writecurrentSelect the rate mode (symbol rate or bit rate). The selected rate will be kept constant when other parameters have impact a the modulator rate. Only the select…
1.3.6.1.4.1.5835.5.2.1000.1.24ScalarntcDvbModSymbolRateread-writecurrentDefine the required symbol rate in baud.
1.3.6.1.4.1.5835.5.2.1000.1.25ScalarntcDvbModBitRateread-writecurrentDefine the required bit rate of the modulator. Current devices support a range of 50000 to 250000000 bps.
1.3.6.1.4.1.5835.5.2.1000.1.26ScalarntcDvbModMeasuredPktCountread-onlycurrentMeasured TS packet count of the modulator.
1.3.6.1.4.1.5835.5.2.1000.1.27ScalarntcDvbModMeasuredBitRateread-onlycurrentMeasured bitrate of the modulator.
1.3.6.1.4.1.5835.5.2.1000.1.28ScalarntcDvbModResetread-writecurrentReset the modulator monitoring counters.
1.3.6.1.4.1.5835.5.2.1000.1.29IdentityntcDvbModS2ExtcurrentContainer holding ntcDvbModS2Ext definitions.
1.3.6.1.4.1.5835.5.2.1000.1.29.1ScalarntcDvbModS2ExtModCodread-writecurrentThe list of S2 Extensions MODCODs is an extension to the standard DVB-S2 MODCODs. The new MODCODs offer improved efficiency if transmission conditions allow it.
1.3.6.1.4.1.5835.5.2.1000.1.29.2ScalarntcDvbModS2ExtPhyLayerEfficiencyread-onlycurrentThe measured physical layer efficiency, equal to the percentage of non-dummy physical layer frames. Float represented as integer is scaled by a factor of 100. …
1.3.6.1.4.1.5835.5.2.1000.1.29.3ScalarntcDvbModS2ExtBbLayerEfficiencyread-onlycurrentThe measured baseband layer efficiency, equal to the percentage user data in tbe baseband frames. Float represented as integer is scaled by a factor of 100. i.…
1.3.6.1.4.1.5835.5.2.1000.1.29.4ScalarntcDvbModS2ExtDumPlScramblModeread-writecurrentThe dummy physical layer scrambler mode can be set to continuous, to achieve more randomness in the carrier data as required for bandwidth cancellation.
1.3.6.1.4.1.5835.5.2.1000.1.29.5ScalarntcDvbModS2ExtPlScrambSigread-writecurrentThe physical layer scrambler signature.
1.3.6.1.4.1.5835.5.2.1000.1.29.6ScalarntcDvbModS2ExtRollOffSignallingread-writecurrentWhen a Roll-off <20% is configured, this setting is used to put the Roll-off bits in the baseband header to reserved (11) or to a standardized value. Some rece…
1.3.6.1.4.1.5835.5.2.1000.1.30IdentityntcDvbModTurbocurrentContainer holding ntcDvbModTurbo definitions.
1.3.6.1.4.1.5835.5.2.1000.1.30.1ScalarntcDvbModTurboModCodread-writecurrentThe selection of the FEC code-rate and modulation scheme supported by TURBO
1.3.6.1.4.1.5835.5.2.1000.1.30.2ScalarntcDvbModTurboDeleteSyncread-writecurrentEnable or disable deletion of the sync byte
1.3.6.1.4.1.5835.5.2.1000.1.31IdentityntcDvbModAmcDvbscurrentContainer holding ntcDvbModAmcDvbs definitions.
1.3.6.1.4.1.5835.5.2.1000.1.31.1ScalarntcDvbModAmcDvbsModCodread-writecurrentThe selection of the FEC code-rate and modulation scheme supported by AMC-S
1.3.6.1.4.1.5835.5.2.1000.1.32IdentityntcDvbModAmcNbccurrentContainer holding ntcDvbModAmcNbc definitions.
1.3.6.1.4.1.5835.5.2.1000.1.32.1ScalarntcDvbModAmcNbcFrameTyperead-writecurrentDvb-S2 defines 2 FEC-frame types : - normal: FECframes of 64800 bits or 8100 bytes - short: FECframes of 16200 bits or 2025 bytes Short frames are used when wo…
1.3.6.1.4.1.5835.5.2.1000.1.32.2ScalarntcDvbModAmcNbcModCodread-writecurrentThe selection of modulation type and the FEC rate.
1.3.6.1.4.1.5835.5.2.1000.1.32.3ScalarntcDvbModAmcNbcPilotsread-writecurrentDvb-S2 Physical Layer Pilot insertion. When enabled, every 16 slots (of 90 symbols) the modulator will insert 36 unmodulated symbols to aid in receiver synchro…
1.3.6.1.4.1.5835.5.2.1000.1.32.4ScalarntcDvbModAmcNbcPLEfficiencyread-onlycurrentThe measured physical layer efficiency, equal to the percentage of non-dummy physical layer frames. Float represented as integer is scaled by a factor of 100. …
1.3.6.1.4.1.5835.5.2.1000.1.32.5ScalarntcDvbModAmcNbcBbLayerEfficiencyread-onlycurrentThe measured baseband layer efficiency, equal to the percentage user data in tbe baseband frames. Float represented as integer is scaled by a factor of 100. i.…
1.3.6.1.4.1.5835.5.2.1000.1.32.6ScalarntcDvbModAmcNbcPlHdrScrmSeqread-writecurrentPhysical layer scrambling sequence key
1.3.6.1.4.1.5835.5.2.1000.1.32.7ScalarntcDvbModAmcNbcRollOffSignallingread-writecurrentWhen a Roll-off <20% is configured, this setting is used to put the Roll-off bits in the baseband header to reserved (11) or to a standardized value. Some rece…
1.3.6.1.4.1.5835.5.2.1000.1.33ScalarntcDvbModActualOutputLevelread-onlycurrentModulator output level setting in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '…
1.3.6.1.4.1.5835.5.2.1000.1.34ScalarntcDvbModTransmitStateReasonread-onlycurrentReason for current Transmit State
1.3.6.1.4.1.5835.5.2.1000.1.35IdentityntcDvbModLinkOptcurrentContainer holding ntcDvbModLinkOpt definitions.
1.3.6.1.4.1.5835.5.2.1000.1.35.1ScalarntcDvbModLinkOptTransModeread-writecurrentTransponder Operation Mode selection.
1.3.6.1.4.1.5835.5.2.1000.1.35.2ScalarntcDvbModMaxModulationread-writecurrentThe maximum modulation order to which the outbound carrier is optimized.
1.3.6.1.4.1.5835.5.2.1000.1.36ScalarntcDvbModAllowChangesWhileTxOnread-writecurrentThis field allows you to choose if the main modulation parameters can be altered while the transmit is on.
1.3.6.1.4.1.5835.5.2.1000.1.37ScalarntcDvbModStandbyRedundancyStateread-writecurrentDefault connector redundancy state when the Device Redundancy is in standby mode.
1.3.6.1.4.1.5835.5.2.1000.1.38IdentityntcDvbModDSNGProfilescurrentContainer holding ntcDvbModDSNGProfiles definitions.
1.3.6.1.4.1.5835.5.2.1000.1.38.38ScalarntcDvbModDSNGProfilesProfileread-writecurrentDSNG profile is named after its occupied bandwidth
1.3.6.1.4.1.5835.5.2.1000.1.38.39ScalarntcDvbModDSNGProfilesLevelread-writecurrentDSNG profile level that defines the proposed application
1.3.6.1.4.1.5835.5.2.1000.1.39ScalarntcDvbModStreamModeread-writecurrentSpecify if more than one input stream is multiplexed into the modulator or not. This sometimes impacts receiver compatibility.
1.3.6.1.4.1.5835.5.2.1000.1.40IdentityntcDvbModAmcDlcurrentContainer holding ntcDvbModAmcDl definitions.
1.3.6.1.4.1.5835.5.2.1000.1.40.1ScalarntcDvbModAmcDlModCodread-writecurrentThe selection of the FEC code-rate and modulation scheme supported by AMC-DL
1.3.6.1.4.1.5835.5.2.1000.1.41ScalarntcDvbModIfOutputLevelread-writecurrentModulator output level setting in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '…
1.3.6.1.4.1.5835.5.2.1000.1.42ScalarntcDvbModLbandOutputLevelread-writecurrentModulator output level setting in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '…
1.3.6.1.4.1.5835.5.2.1000.1.43ScalarntcDvbModIfOutputFrequencyread-writecurrentWhen the IF to L-Band converter is inside the device, then both IF and L-Band is available at the same time at the output of the device. This means that 2 inde…
1.3.6.1.4.1.5835.5.2.1000.1.44ScalarntcDvbModLbandOutputFrequencyread-writecurrentWhen the IF to L-Band converter is inside the device, then both IF and L-Band is available at the same time at the output of the device. This means that 2 inde…
1.3.6.1.4.1.5835.5.2.1000.1.45ScalarntcDvbModLbandTxread-writecurrentEnable or disable the modulator L-Band output transmit signal. When it is enabled the actual output can still be switched-off upon detection of e.g. general de…
1.3.6.1.4.1.5835.5.2.1000.1.46ScalarntcDvbModLbandTxStateread-onlycurrentCurrent L-Band transmit status of the modulator (on or off). The actual transmit status is determined by the transmit configuration parameter and by other even…
1.3.6.1.4.1.5835.5.2.1000.1.47ScalarntcDvbModLbandTxStateReasonread-onlycurrentReason for current L-Band Transmit State
1.3.6.1.4.1.5835.5.2.1000.1.48IdentityntcDvbModExtConvcurrentContainer holding ntcDvbModExtConv definitions.
1.3.6.1.4.1.5835.5.2.1000.1.48.1ScalarntcDvbModExtConvEnableread-writecurrentEnable or disable the external convertor frequency specification
1.3.6.1.4.1.5835.5.2.1000.1.48.2ScalarntcDvbModExtConvRfFrequencyread-writecurrentRF frequency
1.3.6.1.4.1.5835.5.2.1000.1.48.3ScalarntcDvbModExtConvLoFrequencyread-writecurrentLO frequency
1.3.6.1.4.1.5835.5.2.1000.1.48.4ScalarntcDvbModExtConvSpectrumInvread-writecurrentSpecifies in the external LO converter inverts the spectrum or not.
1.3.6.1.4.1.5835.5.2.1000.1.49IdentityntcDvbModConvcurrentContainer holding ntcDvbModConv definitions.
1.3.6.1.4.1.5835.5.2.1000.1.49.1ScalarntcDvbModConvRfFrequencyread-writecurrentRF frequency
1.3.6.1.4.1.5835.5.2.1000.1.49.2ScalarntcDvbModConvExtLbandTxread-writecurrentEnables or disables block upconverter output of the external L-band input signal.
1.3.6.1.4.1.5835.5.2.1000.1.49.3ScalarntcDvbModConvLoFrequencyread-onlycurrentConverter module LO frequency
1.3.6.1.4.1.5835.5.2.1000.1.49.4ScalarntcDvbModConvRfGainread-onlycurrentGain of the installed converter module.
1.3.6.1.4.1.5835.5.2.1000.1.49.5ScalarntcDvbModConvOutputLevelread-writecurrentConverter output level setting in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '…
1.3.6.1.4.1.5835.5.2.1000.1.50ScalarntcDvbModExtCableLossread-writecurrentModulator external cable loss in dBm. Adjustable in steps of 0.1 dBm. Float represented as integer is scaled by a factor of 10. i.e. a value of '-103' means '-…
1.3.6.1.4.1.5835.5.2.1000.2IdentityntcDvbModConformancecurrentConformance requirements.
1.3.6.1.4.1.5835.5.2.1000.2.1IdentityntcDvbModConfCompliancecurrentDevice compliance statements.
1.3.6.1.4.1.5835.5.2.1000.2.1.1CompliancentcDvbModConfCompV1StandardcurrentCompliance statement for Newtec device MIB implementations.
1.3.6.1.4.1.5835.5.2.1000.2.2IdentityntcDvbModConfGroupcurrentGroups used by device compliance statements.
1.3.6.1.4.1.5835.5.2.1000.2.2.1GroupntcDvbModConfGrpV1StandardcurrentManaged objects that constitute version 1 of a system device with standard capabilities.
1.3.6.1.4.1.5835.5.2.1000.2.2.2GroupntcDvbModConfGrpObsoleteobsoleteManaged objects which are deprecated or obsolete