NEXANS-BM-MIB
160 objects
MIB for Nexans switches
Imported Objects
| BRIDGE-MIB | dot1dStpPortState |
| NEXANS-MIB | nexansANS |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString MacAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.266.20 | IdentitybmSwitchMIB | MIB for Nexans switches | ||
| 1.3.6.1.4.1.266.20.0 | NodebmTraps | |||
| 1.3.6.1.4.1.266.20.0.1 | NotificationswitchTemperatureFailure | current | A TemperatureFailure signifies that the switch hardware has detected under- or overtemperature condition. | |
| 1.3.6.1.4.1.266.20.0.2 | NotificationportLinkChange | current | The trap is sent whenever the link state of a port changes from link-up to link-down or from link-down to link-up | |
| 1.3.6.1.4.1.266.20.0.3 | NotificationportNewMacAddress | current | A new source MAC address has been detected on a switch port. This trap is only send for ports which have port-security enabled with the setting autoAllowOneMac… | |
| 1.3.6.1.4.1.266.20.0.4 | NotificationportSecurityFailure | current | An unauthorized source MAC address has accessed a port which has port-security enabled. | |
| 1.3.6.1.4.1.266.20.0.5 | NotificationportErrorCountFailure | current | The port error counter has incremented by 2 or more within a timewindow of two seconds. An counter increment by 1 ist not reported because single increments of… | |
| 1.3.6.1.4.1.266.20.0.6 | NotificationswitchMgmtAuthFailure | current | A station has tried to access the switch management with a wrong authentication. This includes wrong user/password for telnet, wrong community for SNMP read/wr… | |
| 1.3.6.1.4.1.266.20.0.7 | NotificationradiusMgmtAuthReject | current | A station has tried to access the switch management with radius authentication enabled and the radius server has rejected the request. | |
| 1.3.6.1.4.1.266.20.0.8 | NotificationradiusPortSecurityReject | current | A station has tried to access the switch with radius port security authentication enabled and the radius server has rejected the request. | |
| 1.3.6.1.4.1.266.20.0.9 | NotificationportLoopBcastFailure | current | The port broadcast/multicast counter has incremented by 25 packets/second for more then 10 successive seconds. Excessive multicast or broadcast packets may res… | |
| 1.3.6.1.4.1.266.20.0.10 | NotificationswitchPoeVoltageFailure | current | The switch has detected a PoE over- or undervoltage conditions. | |
| 1.3.6.1.4.1.266.20.0.11 | NotificationswitchPoeOverloadFailure | current | The switch has detected a overload for the PoE power supply. | |
| 1.3.6.1.4.1.266.20.0.12 | NotificationportPoeOverloadFailure | current | The switch has detected a PoE overload condition at the port. | |
| 1.3.6.1.4.1.266.20.0.13 | NotificationportActiveLoopDetectionFailure | current | The active loop protection has disabled the port. | |
| 1.3.6.1.4.1.266.20.0.14 | NotificationswitchIndustrialAlarmM1 | current | The alarm state of the industrial alarm output M1 has changed. | |
| 1.3.6.1.4.1.266.20.0.15 | NotificationswitchIndustrialAlarmM2 | current | The alarm state of the industrial alarm output M2 has changed. | |
| 1.3.6.1.4.1.266.20.0.16 | NotificationswitchInternalVoltageFailure | current | The switch has detected a internal over- or undervoltage conditions. | |
| 1.3.6.1.4.1.266.20.0.17 | NotificationtftpMessage | current | An successful or failed TFTP transfer has been occured. This does not include TFTP transfers executed from Nexan Manager. | |
| 1.3.6.1.4.1.266.20.0.18 | NotificationsfpEvent | current | The switch has detected one of the following SFP events: - a SFP module has been inserted - a SFP module has been removed - the optical receive power has falle… | |
| 1.3.6.1.4.1.266.20.0.19 | NotificationclientRemoved | current | The client on this port has been removed because the link down time has exceeded the configured 'Link Down Timeout'. | |
| 1.3.6.1.4.1.266.20.0.20 | NotificationinternalMgmtWarning | current | An internal management warning has been detected. Please consult Nexans for further informations regarding the reported warning code. | |
| 1.3.6.1.4.1.266.20.0.21 | NotificationswitchFunctionInputAlarm | current | The state of a function input 1...4 has changed. | |
| 1.3.6.1.4.1.266.20.0.22 | NotificationswitchConfigurationChanged | current | The configuration of the switch has been changed. | |
| 1.3.6.1.4.1.266.20.0.23 | NotificationportErrorDisabled | current | The port has been error disabled. | |
| 1.3.6.1.4.1.266.20.0.24 | NotificationportStateChanged | current | The port state has been changed from blocking to forwarding or vice versa. | |
| 1.3.6.1.4.1.266.20.1 | NodebmSwitchInfo | |||
| 1.3.6.1.4.1.266.20.1.1 | ScalarinfoDescr | read-only | current | The ordering description of the switch |
| 1.3.6.1.4.1.266.20.1.2 | ScalarinfoType | read-only | current | The infoType indentifies the product familie of this switch. Refer to NEXANS-MIB for the currently defined families |
| 1.3.6.1.4.1.266.20.1.3 | ScalarinfoProductNo | read-only | current | The product number of the switch (8830xxxx) |
| 1.3.6.1.4.1.266.20.1.4 | ScalarinfoSerie | read-only | current | The production series of the switch |
| 1.3.6.1.4.1.266.20.1.5 | ScalarinfoSeriesNo | read-only | current | The production number of the switch |
| 1.3.6.1.4.1.266.20.1.6 | ScalarinfoManufactureDate | read-only | current | The manufacturing date of the switch. The display format is dd.mm.jjjj |
| 1.3.6.1.4.1.266.20.1.7 | ScalarinfoSwitchHardwareVersion | read-only | current | The hardware version of the base switch. |
| 1.3.6.1.4.1.266.20.1.8 | ScalarinfoMgmtHardwareVersion | read-only | current | The hardware version of the plug-in management module. |
| 1.3.6.1.4.1.266.20.1.9 | ScalarinfoMgmtFirmwareVersion | read-only | current | The firmware version of the management module. |
| 1.3.6.1.4.1.266.20.1.10 | ScalarinfoNoOfPorts | read-only | current | The number of switching ports within the system. This includes all user and uplink ports. |
| 1.3.6.1.4.1.266.20.1.11 | ScalarinfoNoOfReboots | read-only | current | The number of reboots since the manufacturing date. This counter can't be cleared by any admin command. |
| 1.3.6.1.4.1.266.20.1.12 | ScalarinfoTemperature | read-only | current | The case temperature in degree Celsius of the switch. |
| 1.3.6.1.4.1.266.20.1.13 | ScalarinfoTemperatureMaxAllowed | read-only | current | The upper limit of the allowed temperature range in degree Celsius. If the current temperature indicated by infoTemperature exceeds infoTemperatureMaxAllowed, … |
| 1.3.6.1.4.1.266.20.1.14 | ScalarinfoPowerVoltage2500 | read-only | current | The 2.5 volt supply voltage in millivolts. The allowed range is 2300...2700 millivolts. |
| 1.3.6.1.4.1.266.20.1.15 | ScalarinfoPowerVoltage3300 | read-only | current | The 3.3 volt supply voltage in millivolts. The allowed range is 3100...3500 millivolts. |
| 1.3.6.1.4.1.266.20.1.16 | ScalarinfoUnauthIpAddr | read-only | current | The source IP address of the station which generated the last authentication failure. The infoUnauthAddr is also reported in the switchMgmtAuthFailure alarm tr… |
| 1.3.6.1.4.1.266.20.1.17 | ScalarinfoSecurityFailMacAddr | read-only | current | The source MAC address of the station which has generated a the last port security failure. The infoSecurityFailMacAddr is also reported in the portSecurityFai… |
| 1.3.6.1.4.1.266.20.1.18 | ScalarinfoNewMacAddr | read-only | current | The last new source MAC address seen on a port witch has portsecurity enabled. The infoNewMacAddr is also reported in the newMacAddress trap. |
| 1.3.6.1.4.1.266.20.1.19 | ScalarinfoPoeInputVoltage | read-only | current | The current PoE input voltage delivered from the power supply. |
| 1.3.6.1.4.1.266.20.1.20 | ScalarinfoPoeInputPower | read-only | current | The current PoE input power delivered from the power supply. |
| 1.3.6.1.4.1.266.20.1.21 | ScalarinfoAlarmStateM1 | read-only | current | The current state of the industrial alarm output M1. |
| 1.3.6.1.4.1.266.20.1.22 | ScalarinfoAlarmStateM2 | read-only | current | The current state of the industrial alarm output M2. |
| 1.3.6.1.4.1.266.20.1.23 | ScalarinfoLastTftpMessage | accessible-for-notify | current | The message of the last successful or failed TFTP transfer. This does not include TFTP transfers executed from Device Manager. |
| 1.3.6.1.4.1.266.20.1.24 | ScalarinfoLastSfpEventMessage | accessible-for-notify | current | The last event message from one of the available SFP modules. |
| 1.3.6.1.4.1.266.20.1.25 | ScalarinfoLastInternalMgmtWarning | accessible-for-notify | current | The last internal management warning message. |
| 1.3.6.1.4.1.266.20.1.26 | ScalarinfoFunctionInputStateF1 | read-only | current | The current state of the function input F1. |
| 1.3.6.1.4.1.266.20.1.27 | ScalarinfoTotalConfigChanges | read-only | current | The number of total configurations changes. |
| 1.3.6.1.4.1.266.20.1.28 | ScalarinfoLastConfigChangeSource | accessible-for-notify | current | The source of the last configuration change. |
| 1.3.6.1.4.1.266.20.1.29 | ScalarinfoLastPortStateChangeSource | accessible-for-notify | current | The source of the last port status change from blocking to forwarding or vice versa. |
| 1.3.6.1.4.1.266.20.1.30 | ScalarinfoFunctionInputStateF2 | read-only | current | The current state of the function input F2. |
| 1.3.6.1.4.1.266.20.1.31 | ScalarinfoFunctionInputStateF3 | read-only | current | The current state of the function input F3. |
| 1.3.6.1.4.1.266.20.1.32 | ScalarinfoFunctionInputStateF4 | read-only | current | The current state of the function input F4. |
| 1.3.6.1.4.1.266.20.1.33 | ScalarinfoLastFuncInputAlarmNumber | accessible-for-notify | current | The number (1..4) of the function input which causes the last function input alarm. This object is only used for trap switchFunctionInputAlarm(21) |
| 1.3.6.1.4.1.266.20.1.34 | ScalarinfoLastFuncInputAlarmState | accessible-for-notify | current | The state of the function input which causes the last function input alarm. This object is only used for trap switchFunctionInputAlarm(21) |
| 1.3.6.1.4.1.266.20.1.35 | ScalarinfoLastFuncInputAlarmName | accessible-for-notify | current | The administratively assigned name of the function input which causes the last function input alarm. This object is only used for trap switchFunctionInputAlarm… |
| 1.3.6.1.4.1.266.20.2 | NodebmSwitchAdmin | |||
| 1.3.6.1.4.1.266.20.2.1 | ScalaradminReset | read-write | current | Writing this object causes the switch to perform a reset operation. The following reset types are supported. Set Values: resetCounters(2) This action resets al… |
| 1.3.6.1.4.1.266.20.2.2 | ScalaradminAgentDhcp | read-write | current | If set to enable(1), the switch tries to get his IP parameter via DHCP. If set to disable(2), the switch uses the IP parameters defined with adminIpAddress, ad… |
| 1.3.6.1.4.1.266.20.2.3 | ScalaradminAgentIpAddress | read-write | current | The IP address of the switch agent's ethernet interface. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect… |
| 1.3.6.1.4.1.266.20.2.4 | ScalaradminAgentPhysAddress | read-only | current | The Ethernet MAC address of the switch agent. |
| 1.3.6.1.4.1.266.20.2.5 | ScalaradminAgentDefRouterIpAddress | read-write | current | The IP address of the default Router. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next swi… |
| 1.3.6.1.4.1.266.20.2.6 | ScalaradminAgentNetmask | read-write | current | The IP Netmask of the connected network. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next … |
| 1.3.6.1.4.1.266.20.2.7 | ScalaradminAgentDhcpServerIpAddress | read-only | current | The IP address of the last used DHCP server. |
| 1.3.6.1.4.1.266.20.2.8 | ScalaradminAgentVlanId | read-write | current | The VLAN-ID assigned to the agent. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5… |
| 1.3.6.1.4.1.266.20.2.9 | ScalaradminAgentPrioValue | read-write | current | The IEEE802.1Q priority value and queue assigned to all frames transmitted by the agent. The definition between value, service class and queue are as follows: … |
| 1.3.6.1.4.1.266.20.2.10 | ScalaradminAddrAgingTimeMinutes | read-write | current | The timeout period in minutes for aging out dynamically learned MAC addresses . The allowed range is 1 minute to 68 minutes. |
| 1.3.6.1.4.1.266.20.2.11 | ScalaradminSwitchPortMirror | read-write | current | If set to enable(1), the switch doesn't use address learning. This affects that any received packet will be forwarded to all ports of the particular VLAN. The … |
| 1.3.6.1.4.1.266.20.2.12 | ScalaradminMgmtAccessList | read-write | current | If set to enableForNexManAccess(2) or enableForAllAccess(3), the switch only accepts read or write requests from IP addresses which are listed in the managemen… |
| 1.3.6.1.4.1.266.20.2.13 | ScalaradminSwitchPoEPowerLimit | read-write | current | The limit for the POE input power from the power supply in VA. If the current power exceeds this value a overload conditions occurs and the inline power for th… |
| 1.3.6.1.4.1.266.20.2.14 | ScalaradminSwitchVlanTableMode | read-write | current | If set to staticMode(1) or staticModeVlans64(3) any existing VLAN table entry must be removed manually by management. With staticMode(1) total 16 VLAN-ID's and… |
| 1.3.6.1.4.1.266.20.2.15 | ScalaradminUnsecureVlanId | read-write | current | The VLAN-ID of the unsecure VLAN |
| 1.3.6.1.4.1.266.20.2.16 | ScalaradminDot1xAuthFailureVlanId | read-write | current | The VLAN-ID in the case of an IEEE802.1X authentication failure. Setting the VLAN-ID to 0 disables the authentication failure VLAN. |
| 1.3.6.1.4.1.266.20.2.17 | ScalaradminTftpAccess | read-write | current | If 'TFTP authentication via SNMP' is disabled, this value is allways tftpAccessDisable(1). If 'TFTP authentication via SNMP' is read/only or read/write, an thi… |
| 1.3.6.1.4.1.266.20.2.18 | ScalaradminSnmpMacTableMode | read-write | current | If set to listAllPorts(1) the BRIDGE-MIBs dot1dTpFdbTable lits MAC address of all ports. If set to listUserPortsOnly(2) the BRIDGE-MIBs dot1dTpFdbTable lits on… |
| 1.3.6.1.4.1.266.20.2.19 | ScalaradminAlarmM1 | read-write | current | The current setup of the industrial alarm output M1. |
| 1.3.6.1.4.1.266.20.2.20 | ScalaradminAlarmM2 | read-write | current | The current setup of the industrial alarm output M2. |
| 1.3.6.1.4.1.266.20.2.21 | ScalaradminMemoryCardMode | read-write | current | If set to mcDisabled(2), the memory card is disabled but may be re-enabled later by writing mcEnabled(1). If set to mcPermanentDisabled(3), the memory card is … |
| 1.3.6.1.4.1.266.20.2.22 | ScalaradminAlarmNameM1 | read-write | current | An administratively assigned name for alarm output M1. The configured name will be send as part of alarm message switchIndustrialAlarmM1. |
| 1.3.6.1.4.1.266.20.2.23 | ScalaradminAlarmNameM2 | read-write | current | An administratively assigned name for alarm output M1. The configured name will be send as part of alarm message switchIndustrialAlarmM2. |
| 1.3.6.1.4.1.266.20.2.24 | ScalaradminFunctionInputNameF1 | read-write | current | An administratively assigned name for function input F1. The configured name will be send as part of alarm message switchFunctionInputAlarm. |
| 1.3.6.1.4.1.266.20.2.25 | ScalaradminLedGlobalMode | read-write | current | Set the global mode for all front side LEDs. |
| 1.3.6.1.4.1.266.20.2.26 | ScalaradminFunctionInputNameF2 | read-write | current | An administratively assigned name for function input F2. The configured name will be send as part of alarm message switchFunctionInputAlarm. |
| 1.3.6.1.4.1.266.20.2.27 | ScalaradminFunctionInputNameF3 | read-write | current | An administratively assigned name for function input F2. The configured name will be send as part of alarm message switchFunctionInputAlarm. |
| 1.3.6.1.4.1.266.20.2.28 | ScalaradminFunctionInputNameF4 | read-write | current | An administratively assigned name for function input F2. The configured name will be send as part of alarm message switchFunctionInputAlarm. |
| 1.3.6.1.4.1.266.20.3 | NodebmSwitchPort | |||
| 1.3.6.1.4.1.266.20.3.1 | TablebmSwitchPortTable | not-accessible | current | A list of port entries for the switch. The number of entries is defined by ifNumber. |
| 1.3.6.1.4.1.266.20.3.1.1 | RowbmSwitchPortEntry | not-accessible | current | A port entry in the table containing information about a port in the switch. |
| 1.3.6.1.4.1.266.20.3.1.1.1 | ColumnportIndex | read-only | current | A unique value for each port. Its value ranges between 1 and the value of ifNumber. The port identified by a particular value of this index is the same port as… |
| 1.3.6.1.4.1.266.20.3.1.1.2 | ColumnportDescr | read-only | current | A textual string containing information about the interface. Same as ifDescr. |
| 1.3.6.1.4.1.266.20.3.1.1.3 | ColumnportName | read-write | current | An administratively assigned name for this port. |
| 1.3.6.1.4.1.266.20.3.1.1.4 | ColumnportAdminState | read-write | current | A value indicating the current state of the port. A SET to this object enables (2) or disables (3) the port. The possible values returned by GET are: allwaysEn… |
| 1.3.6.1.4.1.266.20.3.1.1.5 | ColumnportSpeedDuplexSetup | read-write | current | A value indicating the current speed and duplex link setup. Independent of portSpeedDuplexSetup the port may be disabled by portAdminState. |
| 1.3.6.1.4.1.266.20.3.1.1.6 | ColumnportLinkState | read-only | current | A value indicating the current link state. |
| 1.3.6.1.4.1.266.20.3.1.1.7 | ColumnportErrorCounter | read-only | current | Errors are usually caused by a FDX/HDX mismatch between the switch port and the connected port. If the switch detects a incrementation of this counter, he will… |
| 1.3.6.1.4.1.266.20.3.1.1.8 | ColumnportRemoteFault | read-write | current | If portRemoteFault is enabled for this port, the port transmitter will be only enabled if the port receiver has a valid link (portLinkState must not be down). |
| 1.3.6.1.4.1.266.20.3.1.1.9 | ColumnportDefaultVlanId | read-write | current | The Default-VLAN-ID assigned to this port. This Default-VLAN-ID has differnt affects depending on received or transmited frames: a) All received frames, which … |
| 1.3.6.1.4.1.266.20.3.1.1.10 | ColumnportTrunkingMode | read-write | current | If portTrunkingMode is set to dot1qTagging, all frames are transmited with a VLAN-tag, except frames which belong to portNativeVlanId. If portTrunkingMode is s… |
| 1.3.6.1.4.1.266.20.3.1.1.11 | ColumnportDot1qDefaultPrioValue | read-write | current | The default IEEE802.1Q priority and queue assigned all frames received on this port, for which no other priorisation applies (IEEE801.1q Tag or IPv4/IPv6). The… |
| 1.3.6.1.4.1.266.20.3.1.1.12 | ColumnportDefaultPrioQueue | read-only | current | The default priority queue assigned all frames received on this port, for which no other priorisation applies (IEEE801.1q Tag or IPv4/IPv6). A value of 0 means… |
| 1.3.6.1.4.1.266.20.3.1.1.13 | ColumnportLEDGreen | read-write | current | The function of the green port LED. Only supported for user ports |
| 1.3.6.1.4.1.266.20.3.1.1.14 | ColumnportLEDYellow | read-write | current | The function of the yellow port LED. Only supported for user ports |
| 1.3.6.1.4.1.266.20.3.1.1.15 | ColumnportBandwidthLimitRxd | read-write | current | The bandwidth limiter for received packets. If set to disable(2) the limiter will be disabled. |
| 1.3.6.1.4.1.266.20.3.1.1.16 | ColumnportBandwidthLimitTxd | read-write | current | The bandwidth limiter for transmitted packets. If set to disable(2) the limiter will be disabled. |
| 1.3.6.1.4.1.266.20.3.1.1.17 | ColumnportSecurityAdminState | read-write | current | Enables the port security feature for that port. A value of notSupported(1) means, that port security ist not supported or disabled for that port (i.e. uplink … |
| 1.3.6.1.4.1.266.20.3.1.1.18 | ColumnportSecurityMacAddr1 | read-write | current | The first MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(1… |
| 1.3.6.1.4.1.266.20.3.1.1.19 | ColumnportSecurityMacAddr2 | read-write | current | The second MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(… |
| 1.3.6.1.4.1.266.20.3.1.1.20 | ColumnportSecurityMacAddr3 | read-write | current | The third MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(1… |
| 1.3.6.1.4.1.266.20.3.1.1.21 | ColumnportPoeAdminState | read-write | current | If no POE adapter is installed this object is read-only and will always report notSupported(1). The possible values are: notSupported(1): No adapter installed … |
| 1.3.6.1.4.1.266.20.3.1.1.22 | ColumnportPoeVoltage | read-only | current | The current PoE output voltage at this port in volts. |
| 1.3.6.1.4.1.266.20.3.1.1.23 | ColumnportPoeCurrent | read-only | current | The current PoE output current at this port in milliampere. |
| 1.3.6.1.4.1.266.20.3.1.1.24 | ColumnportPoePower | read-only | current | The current PoE output power at this port in milliwatt. The output power is the product of portPoeVoltage and portPoeCurrent. |
| 1.3.6.1.4.1.266.20.3.1.1.25 | ColumnportSecurityForwardingState | read-only | current | The port security forwarding state of that port. See documentation for details. |
| 1.3.6.1.4.1.266.20.3.1.1.26 | ColumnportPoePowerLimit | read-write | current | The limit for the POE output power at this port in VA. If the current power exceeds this value a overload conditions occurs and the inline power for that port … |
| 1.3.6.1.4.1.266.20.3.1.1.27 | ColumnportLimiterPacketType | read-write | current | The packet type for bandwidth limiter. If set to limitAllPacktes(2) then all packets are limited. If set to limitLoppBcastPackets(3) only flooted loop- and bro… |
| 1.3.6.1.4.1.266.20.3.1.1.28 | ColumnportAcApSetup | read-write | current | If portAcApSetup is enabled, the switch will perform Autocrossover and Autopolarity for this port. This function should only be enabled if portSpeedDuplexSetup… |
| 1.3.6.1.4.1.266.20.3.1.1.29 | ColumnportLinkType | read-write | current | The link type of that port. If set to upDownlink(3) the portAdminState will be forced to enable. |
| 1.3.6.1.4.1.266.20.3.1.1.30 | ColumnportVoiceVlanId | read-write | current | The Voide-VLAN-ID assigned to this port. Packets of this Voice-VLAN are allway send with a VLAN-Tag, because IP-Phones normaly need a tagged VLAN. If portTrunk… |
| 1.3.6.1.4.1.266.20.3.1.1.31 | ColumnportPrioDot1p | read-write | current | Defines whether port prioritisation for IEEE802.1p packets is enabled. |
| 1.3.6.1.4.1.266.20.3.1.1.32 | ColumnportPrioIp | read-write | current | Defines whether port prioritisation for IPv4/IPv6 packets is enabled. |
| 1.3.6.1.4.1.266.20.3.1.1.33 | ColumnportActiveDefaultVlanId | read-only | current | The currently active Default-VLAN-ID assigned to this port. This is either the configured portDefaultVlanId or the VLAN ID assigned by RADIUS authentication |
| 1.3.6.1.4.1.266.20.3.1.1.34 | ColumnportActiveVoiceVlanId | read-only | current | The currently active Voice-VLAN-ID assigned to this port. This is either the configured portVoiceVlanId or the VLAN ID assigned by RADIUS authentication |
| 1.3.6.1.4.1.266.20.4 | NodebmSwitchVlan | |||
| 1.3.6.1.4.1.266.20.4.1 | TablebmSwitchVlanTable | not-accessible | current | A list of Virtual LAN instances. |
| 1.3.6.1.4.1.266.20.4.1.1 | RowbmSwitchVlanEntry | not-accessible | current | VLAN entry. |
| 1.3.6.1.4.1.266.20.4.1.1.1 | ColumnvlanIndex | read-only | current | A unique value for each VLAN entry. Its value ranges between 1 and 16. |
| 1.3.6.1.4.1.266.20.4.1.1.2 | ColumnvlanId | read-write | current | The VLAN-ID assigned to this entry. Only entries with a VLAN-ID greater then 0 are valid entries. Setting a valid VLAN-ID to 0 will disable that entry and also… |
| 1.3.6.1.4.1.266.20.4.1.1.3 | ColumnvlanDescr | read-write | current | A textual string containing information about the VLAN. |
| 1.3.6.1.4.1.266.20.5 | NodebmSwitchSfp | |||
| 1.3.6.1.4.1.266.20.5.1 | TablebmSwitchSfpTable | not-accessible | current | A list of SFP entries for the switch. The number of entries is defined by ifNumber. |
| 1.3.6.1.4.1.266.20.5.1.1 | RowbmSwitchSfpEntry | not-accessible | current | A SFP entry in the table containing information about a SFP in the switch. |
| 1.3.6.1.4.1.266.20.5.1.1.1 | ColumnsfpPortIndex | read-only | current | A unique value for each port. Its value ranges between 1 and the value of ifNumber. The port identified by a particular value of this index is the same port as… |
| 1.3.6.1.4.1.266.20.5.1.1.2 | ColumnsfpState | read-only | current | A value indicating the current state of the SFP module. The possible values returned are: notSupported(1) The port has no SFP slot. noSfpInserted(2) The port h… |
| 1.3.6.1.4.1.266.20.5.1.1.3 | ColumnsfpInfoVendorName | read-only | current | A textual string containing the vendor name of the SFP module. |
| 1.3.6.1.4.1.266.20.5.1.1.4 | ColumnsfpInfoPartNumber | read-only | current | A textual string containing the part number of the SFP module. |
| 1.3.6.1.4.1.266.20.5.1.1.5 | ColumnsfpInfoRevisionNumber | read-only | current | A textual string containing the revision number of the SFP module. |
| 1.3.6.1.4.1.266.20.5.1.1.6 | ColumnsfpInfoSerialNumber | read-only | current | A textual string containing the serial number of the SFP module. |
| 1.3.6.1.4.1.266.20.5.1.1.7 | ColumnsfpInfoDateCode | read-only | current | A textual string containing the date code of the SFP module. |
| 1.3.6.1.4.1.266.20.5.1.1.8 | ColumnsfpInfoBitRate | read-only | current | A textual string containing the bit rate of the SFP module. The unit is Mbit/s |
| 1.3.6.1.4.1.266.20.5.1.1.9 | ColumnsfpInfoWavelength | read-only | current | A textual string containing the wavelength of the SFP module. The unit is nm. |
| 1.3.6.1.4.1.266.20.5.1.1.10 | ColumnsfpInfoLength9um | read-only | current | A textual string containing the typically supported fiber length for 9um fiber cable. The unit is meters. |
| 1.3.6.1.4.1.266.20.5.1.1.11 | ColumnsfpInfoLength50um | read-only | current | A textual string containing the typically supported fiber length for 50um fiber cable. The unit is meters. |
| 1.3.6.1.4.1.266.20.5.1.1.12 | ColumnsfpInfoLength62um | read-only | current | A textual string containing the typically supported fiber length for 62.5um fiber cable. The unit is meters. |
| 1.3.6.1.4.1.266.20.5.1.1.13 | ColumnsfpInfoConnectorDescr | read-only | current | A textual string containing the connector description of the SFP module. |
| 1.3.6.1.4.1.266.20.5.1.1.14 | ColumnsfpDiagTemperature | read-only | current | The current temperature of the SFP module in degree celsius. |
| 1.3.6.1.4.1.266.20.5.1.1.15 | ColumnsfpDiagSupplyVoltage | read-only | current | The current supply voltage of the SFP module in millivolt. |
| 1.3.6.1.4.1.266.20.5.1.1.16 | ColumnsfpDiagTxBiasCurrent | read-only | current | The current transmitter bias current of the SFP module in milliampere. |
| 1.3.6.1.4.1.266.20.5.1.1.17 | ColumnsfpDiagTxOutputPower | read-only | current | The current transmitter output power of the SFP module in microwatt. |
| 1.3.6.1.4.1.266.20.5.1.1.18 | ColumnsfpDiagTxOutputPowerDbm | read-only | current | The current transmitter output power of the SFP module in dbm. |
| 1.3.6.1.4.1.266.20.5.1.1.19 | ColumnsfpDiagRxIntputPower | read-only | current | The current receiver input power of the SFP module in microwatt. |
| 1.3.6.1.4.1.266.20.5.1.1.20 | ColumnsfpDiagRxInputPowerDbm | read-only | current | The current receiver input power of the SFP module in dbm. |
| 1.3.6.1.4.1.266.20.5.1.1.21 | ColumnsfpAlarmTxBiasCurrentUpperLimit | read-write | current | The maximum allowed transmitter bias current in milliampere. If the current value indicated by sfpDiagTxBiasCurrent exceeds sfpAlarmTxBiasCurrentUpperLimit, th… |
| 1.3.6.1.4.1.266.20.5.1.1.22 | ColumnsfpAlarmTxOutputPowerLowerLimit | read-write | current | The minimum required transmitter output power in microwatt. If the power value indicated by sfpDiagTxOutputPower falls below sfpAlarmTxOutputPowerLowerLimit, t… |
| 1.3.6.1.4.1.266.20.5.1.1.23 | ColumnsfpAlarmRxInputPowerLowerLimit | read-write | current | The minimum required received input power in microwatt. If the power value indicated by sfpDiagRxInputPower falls below sfpAlarmRxInputPowerLowerLimit, the swi… |