NMS-EPON-ONU-OPTICAL-PARAM-ALARM-SET
44 objects
No module-level DESCRIPTION found.
Imported Objects
| NMS-EPON-ONU | nmsEponOnu |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | INTEGER Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | RowStatus |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3320.101.10.6 | NodeonuOpticsParameterAlarmSet | |||
| 1.3.6.1.4.1.3320.101.10.6.1 | TableonuOpticsParameterAlarmSetTable | not-accessible | mandatory | A list of epon onu Optics Parameter Alarm Set table entries. |
| 1.3.6.1.4.1.3320.101.10.6.1.1 | RowonuOpticsParameterAlarmSetEntry | not-accessible | mandatory | A collection of additional objects in the epon onu Optics Parameter AlarmSet property table. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.1 | ColumnifIndex | read-only | mandatory | The only llid of ONU device in System. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.2 | ColumntxPowerAlarmUpLimitEnable | read-write | mandatory | Enable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.3 | ColumntxPowerAlarmUpLimitThreshold | read-write | mandatory | The upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.4 | ColumntxPowerAlarmUpLimitClearThreshold | read-write | mandatory | The upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.5 | ColumntxPowerAlarmUpLimitRowStatus | read-create | mandatory | The row status of tx power upper alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.6 | ColumntxPowerAlarmLowLimitEnable | read-write | mandatory | Enable or disable the alarm of PON low TX power. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.7 | ColumntxPowerAlarmLowLimitThreshold | read-write | mandatory | The low threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.8 | ColumntxPowerAlarmLowLimitClearThreshold | read-write | mandatory | The low threshold tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.9 | ColumntxPowerAlarmLowLimitRowStatus | read-create | mandatory | The row status of tx power low alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.10 | ColumnrxPowerAlarmUpLimitEnable | read-write | mandatory | Enable or disable the alarm of PON hign RX power. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.11 | ColumnrxPowerAlarmUpLimitThreshold | read-write | mandatory | The upper threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.12 | ColumnrxPowerAlarmUpLimitClearThreshold | read-write | mandatory | The upper threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is 82. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.13 | ColumnrxPowerAlarmUpLimitRowStatus | read-create | mandatory | The row status of rx power upper alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.14 | ColumnrxPowerAlarmLowLimitEnable | read-write | mandatory | Enable or disable the alarm of PON low RX power. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.15 | ColumnrxPowerAlarmLowLimitThreshold | read-write | mandatory | The low threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.16 | ColumnrxPowerAlarmLowLimitClearThreshold | read-write | mandatory | The low threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.17 | ColumnrxPowerAlarmLowLimitRowStatus | read-create | mandatory | The row status of rx power low alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.18 | ColumntemperatureAlarmUpLimitEnable | read-write | mandatory | Enable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.19 | ColumntemperatureAlarmUpLimitThreshold | read-write | mandatory | The upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.20 | ColumntemperatureAlarmUpLimitClearThreshold | read-write | mandatory | The upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.21 | ColumntemperatureAlarmUpLimitRowStatus | read-create | mandatory | The row status of temperature upper alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.22 | ColumntemperatureAlarmLowLimitEnable | read-write | mandatory | Enable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.23 | ColumntemperatureAlarmLowLimitThreshold | read-write | mandatory | The low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.24 | ColumntemperatureAlarmLowLimitClearThreshold | read-write | mandatory | The low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.25 | ColumntemperatureAlarmLowLimitRowStatus | read-create | mandatory | The row status of temperature low alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.26 | ColumnvoltageAlarmUpLimitEnable | read-write | mandatory | Enable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.27 | ColumnvoltageAlarmUpLimitThreshold | read-write | mandatory | The upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.28 | ColumnvoltageAlarmUpLimitClearThreshold | read-write | mandatory | The upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.29 | ColumnvoltageAlarmUpLimitRowStatus | read-create | mandatory | The row status of voltage upper alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.30 | ColumnvoltageAlarmLowLimitEnable | read-write | mandatory | Enable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.31 | ColumnvoltageAlarmLowLimitThreshold | read-write | mandatory | The low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.32 | ColumnvoltageAlarmLowLimitClearThreshold | read-write | mandatory | The low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.33 | ColumnvoltageAlarmLowLimitRowStatus | read-create | mandatory | The row status of voltage low alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.34 | ColumncurrentAlarmUpLimitEnable | read-write | mandatory | Enable or disable the alarm of PON high current. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.35 | ColumncurrentAlarmUpLimitThreshold | read-write | mandatory | The upper threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 1310. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.36 | ColumncurrentAlarmUpLimitClearThreshold | read-write | mandatory | The upper threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 1310. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.37 | ColumncurrentAlarmUpLimitRowStatus | read-create | mandatory | The row status of current upper alarm. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.38 | ColumncurrentAlarmLowLimitEnable | read-write | mandatory | Enable or disable the alarm of PON low current. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.39 | ColumncurrentAlarmLowLimitThreshold | read-write | mandatory | The low threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 0. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.40 | ColumncurrentAlarmLowLimitClearThreshold | read-write | mandatory | The low threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 0. |
| 1.3.6.1.4.1.3320.101.10.6.1.1.41 | ColumncurrentAlarmLowLimitRowStatus | read-create | mandatory | The row status of current low alarm. |