MIB Viewer

NMS-EPON-ONU-OPTICAL-PARAM-ALARM-SET

44 objects
No module-level DESCRIPTION found.
Imported Objects
NMS-EPON-ONUnmsEponOnu
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIINTEGER Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCRowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.3320.101.10.6NodeonuOpticsParameterAlarmSet
1.3.6.1.4.1.3320.101.10.6.1TableonuOpticsParameterAlarmSetTablenot-accessiblemandatoryA list of epon onu Optics Parameter Alarm Set table entries.
1.3.6.1.4.1.3320.101.10.6.1.1RowonuOpticsParameterAlarmSetEntrynot-accessiblemandatoryA collection of additional objects in the epon onu Optics Parameter AlarmSet property table.
1.3.6.1.4.1.3320.101.10.6.1.1.1ColumnifIndexread-onlymandatoryThe only llid of ONU device in System.
1.3.6.1.4.1.3320.101.10.6.1.1.2ColumntxPowerAlarmUpLimitEnableread-writemandatoryEnable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.3ColumntxPowerAlarmUpLimitThresholdread-writemandatoryThe upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.
1.3.6.1.4.1.3320.101.10.6.1.1.4ColumntxPowerAlarmUpLimitClearThresholdread-writemandatoryThe upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.
1.3.6.1.4.1.3320.101.10.6.1.1.5ColumntxPowerAlarmUpLimitRowStatusread-createmandatoryThe row status of tx power upper alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.6ColumntxPowerAlarmLowLimitEnableread-writemandatoryEnable or disable the alarm of PON low TX power. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.7ColumntxPowerAlarmLowLimitThresholdread-writemandatoryThe low threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400.
1.3.6.1.4.1.3320.101.10.6.1.1.8ColumntxPowerAlarmLowLimitClearThresholdread-writemandatoryThe low threshold tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400.
1.3.6.1.4.1.3320.101.10.6.1.1.9ColumntxPowerAlarmLowLimitRowStatusread-createmandatoryThe row status of tx power low alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.10ColumnrxPowerAlarmUpLimitEnableread-writemandatoryEnable or disable the alarm of PON hign RX power. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.11ColumnrxPowerAlarmUpLimitThresholdread-writemandatoryThe upper threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.
1.3.6.1.4.1.3320.101.10.6.1.1.12ColumnrxPowerAlarmUpLimitClearThresholdread-writemandatoryThe upper threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is 82.
1.3.6.1.4.1.3320.101.10.6.1.1.13ColumnrxPowerAlarmUpLimitRowStatusread-createmandatoryThe row status of rx power upper alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.14ColumnrxPowerAlarmLowLimitEnableread-writemandatoryEnable or disable the alarm of PON low RX power. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.15ColumnrxPowerAlarmLowLimitThresholdread-writemandatoryThe low threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400.
1.3.6.1.4.1.3320.101.10.6.1.1.16ColumnrxPowerAlarmLowLimitClearThresholdread-writemandatoryThe low threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400.
1.3.6.1.4.1.3320.101.10.6.1.1.17ColumnrxPowerAlarmLowLimitRowStatusread-createmandatoryThe row status of rx power low alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.18ColumntemperatureAlarmUpLimitEnableread-writemandatoryEnable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.19ColumntemperatureAlarmUpLimitThresholdread-writemandatoryThe upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
1.3.6.1.4.1.3320.101.10.6.1.1.20ColumntemperatureAlarmUpLimitClearThresholdread-writemandatoryThe upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
1.3.6.1.4.1.3320.101.10.6.1.1.21ColumntemperatureAlarmUpLimitRowStatusread-createmandatoryThe row status of temperature upper alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.22ColumntemperatureAlarmLowLimitEnableread-writemandatoryEnable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.23ColumntemperatureAlarmLowLimitThresholdread-writemandatoryThe low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
1.3.6.1.4.1.3320.101.10.6.1.1.24ColumntemperatureAlarmLowLimitClearThresholdread-writemandatoryThe low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
1.3.6.1.4.1.3320.101.10.6.1.1.25ColumntemperatureAlarmLowLimitRowStatusread-createmandatoryThe row status of temperature low alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.26ColumnvoltageAlarmUpLimitEnableread-writemandatoryEnable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.27ColumnvoltageAlarmUpLimitThresholdread-writemandatoryThe upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65.
1.3.6.1.4.1.3320.101.10.6.1.1.28ColumnvoltageAlarmUpLimitClearThresholdread-writemandatoryThe upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65.
1.3.6.1.4.1.3320.101.10.6.1.1.29ColumnvoltageAlarmUpLimitRowStatusread-createmandatoryThe row status of voltage upper alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.30ColumnvoltageAlarmLowLimitEnableread-writemandatoryEnable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.31ColumnvoltageAlarmLowLimitThresholdread-writemandatoryThe low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0.
1.3.6.1.4.1.3320.101.10.6.1.1.32ColumnvoltageAlarmLowLimitClearThresholdread-writemandatoryThe low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0.
1.3.6.1.4.1.3320.101.10.6.1.1.33ColumnvoltageAlarmLowLimitRowStatusread-createmandatoryThe row status of voltage low alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.34ColumncurrentAlarmUpLimitEnableread-writemandatoryEnable or disable the alarm of PON high current. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.35ColumncurrentAlarmUpLimitThresholdread-writemandatoryThe upper threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 1310.
1.3.6.1.4.1.3320.101.10.6.1.1.36ColumncurrentAlarmUpLimitClearThresholdread-writemandatoryThe upper threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 1310.
1.3.6.1.4.1.3320.101.10.6.1.1.37ColumncurrentAlarmUpLimitRowStatusread-createmandatoryThe row status of current upper alarm.
1.3.6.1.4.1.3320.101.10.6.1.1.38ColumncurrentAlarmLowLimitEnableread-writemandatoryEnable or disable the alarm of PON low current. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.10.6.1.1.39ColumncurrentAlarmLowLimitThresholdread-writemandatoryThe low threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 0.
1.3.6.1.4.1.3320.101.10.6.1.1.40ColumncurrentAlarmLowLimitClearThresholdread-writemandatoryThe low threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 0.
1.3.6.1.4.1.3320.101.10.6.1.1.41ColumncurrentAlarmLowLimitRowStatusread-createmandatoryThe row status of current low alarm.