NMS-EPON-ONU-PARAM
40 objects
No module-level DESCRIPTION found.
Imported Objects
| NMS-EPON-ONU-TRAP | nmsEponOnuTrap |
| NMS-SMI | nmsEPONGroup |
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| SNMPv2-TC | RowStatus |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3320.101.18.8 | NodenmsOnuPerfNotif | |||
| 1.3.6.1.4.1.3320.101.18.8.1 | ScalarparaStatus | read-write | mandatory | Description. |
| 1.3.6.1.4.1.3320.101.18.8.2 | IdentitynmsOnuPerfNotifV2 | current | Root node for the converted TRAP-TYPEs. | |
| 1.3.6.1.4.1.3320.101.18.8.2.2 | NotificationonuPerformParameterAlarm | current | Description. | |
| 1.3.6.1.4.1.3320.101.201 | NodenmsOnuPerf | |||
| 1.3.6.1.4.1.3320.101.201.1 | NodenmsOnuPerfSet | |||
| 1.3.6.1.4.1.3320.101.201.1.1 | TableonuPerformParameterAlarmsSetTable | not-accessible | mandatory | Description. |
| 1.3.6.1.4.1.3320.101.201.1.1.1 | RowonuPerformParameterAlarmsSetEntry | not-accessible | mandatory | Description. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.1 | ColumnllidIfIndex | read-only | mandatory | Index of LLID interface. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.2 | ColumncpuUsageHighLimitEnable | read-write | mandatory | Enable or disable the alarm of CPU usage. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.3 | ColumncpuUsageHighLimitThreshold | read-write | mandatory | The upper threshold of CPU usage alarm. The unit is 1%. The range is 1-100. Default is 100. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.4 | ColumncpuUsageHighLimitClearThreshold | read-write | mandatory | The upper threshold of CPU usage alarm cleared. The range is 1-100. Default is 100. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.5 | ColumncpuUsageHighLimitRowStatus | read-create | mandatory | The row status of CPU usage alarm . |
| 1.3.6.1.4.1.3320.101.201.1.1.1.6 | ColumnramUsageHighLimitEnable | read-write | mandatory | Enable or disable the alarm of RAM usage. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.7 | ColumnramUsageHighLimitThreshold | read-write | mandatory | The upper threshold of RAM usage alarm. The unit is 1%. The range is 1-100. Default is 100. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.8 | ColumnramUsageHighLimitClearThreshold | read-write | mandatory | The upper threshold of RAM usage alarm cleared. The range is 1-100. Default is 100. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.9 | ColumnramUsageHighLimitRowStatus | read-create | mandatory | The row status of RAM usage alarm . |
| 1.3.6.1.4.1.3320.101.201.1.1.1.10 | ColumntemperatureAlarmUpLimitEnable | read-write | mandatory | Enable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.11 | ColumntemperatureAlarmUpLimitThreshold | read-write | mandatory | The upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.12 | ColumntemperatureAlarmUpLimitClearThreshold | read-write | mandatory | The upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.13 | ColumntemperatureAlarmUpLimitRowStatus | read-create | mandatory | The row status of temperature upper alarm. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.14 | ColumntemperatureAlarmLowLimitEnable | read-write | mandatory | Enable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.15 | ColumntemperatureAlarmLowLimitThreshold | read-write | mandatory | The low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.16 | ColumntemperatureAlarmLowLimitClearThreshold | read-write | mandatory | The low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.17 | ColumntemperatureAlarmLowLimitRowStatus | read-create | mandatory | The row status of temperature low alarm. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.18 | ColumnvoltageAlarmUpLimitEnable | read-write | mandatory | Enable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.19 | ColumnvoltageAlarmUpLimitThreshold | read-write | mandatory | The upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.20 | ColumnvoltageAlarmUpLimitClearThreshold | read-write | mandatory | The upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.21 | ColumnvoltageAlarmUpLimitRowStatus | read-create | mandatory | The row status of voltage upper alarm. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.22 | ColumnvoltageAlarmLowLimitEnable | read-write | mandatory | Enable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.23 | ColumnvoltageAlarmLowLimitThreshold | read-write | mandatory | The low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.24 | ColumnvoltageAlarmLowLimitClearThreshold | read-write | mandatory | The low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0. |
| 1.3.6.1.4.1.3320.101.201.1.1.1.25 | ColumnvoltageAlarmLowLimitRowStatus | read-create | mandatory | The row status of voltage low alarm. |
| 1.3.6.1.4.1.3320.101.201.1.2 | TableonuPerformParameterTable | not-accessible | mandatory | Description. |
| 1.3.6.1.4.1.3320.101.201.1.2.1 | RowonuPerformParameterEntry | not-accessible | mandatory | Description. |
| 1.3.6.1.4.1.3320.101.201.1.2.1.1 | ColumnifIndex | read-write | mandatory | Index of LLID interface. |
| 1.3.6.1.4.1.3320.101.201.1.2.1.2 | ColumncpuUsage | read-write | mandatory | CPU usage . The unit is 1%. The range is 1-100. Default is 0. |
| 1.3.6.1.4.1.3320.101.201.1.2.1.3 | ColumnramUsage | read-write | mandatory | RAM usage. The unit is 1%. The range is 1-100. Default is 0. |
| 1.3.6.1.4.1.3320.101.201.1.2.1.4 | Columntemperature | read-write | mandatory | Temperature.The unit is 0.1 degree. The range is -1280-1280. Default is 0. |
| 1.3.6.1.4.1.3320.101.201.1.2.1.5 | Columnvoltage | read-write | mandatory | Voltage.The unit is 0.1V. The range is 0-65. Default is 0. |