MIB Viewer

NMS-EPON-ONU-PARAM

40 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3320.101.18.8NodenmsOnuPerfNotif
1.3.6.1.4.1.3320.101.18.8.1ScalarparaStatusread-writemandatoryDescription.
1.3.6.1.4.1.3320.101.18.8.2IdentitynmsOnuPerfNotifV2currentRoot node for the converted TRAP-TYPEs.
1.3.6.1.4.1.3320.101.18.8.2.2NotificationonuPerformParameterAlarmcurrentDescription.
1.3.6.1.4.1.3320.101.201NodenmsOnuPerf
1.3.6.1.4.1.3320.101.201.1NodenmsOnuPerfSet
1.3.6.1.4.1.3320.101.201.1.1TableonuPerformParameterAlarmsSetTablenot-accessiblemandatoryDescription.
1.3.6.1.4.1.3320.101.201.1.1.1RowonuPerformParameterAlarmsSetEntrynot-accessiblemandatoryDescription.
1.3.6.1.4.1.3320.101.201.1.1.1.1ColumnllidIfIndexread-onlymandatoryIndex of LLID interface.
1.3.6.1.4.1.3320.101.201.1.1.1.2ColumncpuUsageHighLimitEnableread-writemandatoryEnable or disable the alarm of CPU usage. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.201.1.1.1.3ColumncpuUsageHighLimitThresholdread-writemandatoryThe upper threshold of CPU usage alarm. The unit is 1%. The range is 1-100. Default is 100.
1.3.6.1.4.1.3320.101.201.1.1.1.4ColumncpuUsageHighLimitClearThresholdread-writemandatoryThe upper threshold of CPU usage alarm cleared. The range is 1-100. Default is 100.
1.3.6.1.4.1.3320.101.201.1.1.1.5ColumncpuUsageHighLimitRowStatusread-createmandatoryThe row status of CPU usage alarm .
1.3.6.1.4.1.3320.101.201.1.1.1.6ColumnramUsageHighLimitEnableread-writemandatoryEnable or disable the alarm of RAM usage. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.201.1.1.1.7ColumnramUsageHighLimitThresholdread-writemandatoryThe upper threshold of RAM usage alarm. The unit is 1%. The range is 1-100. Default is 100.
1.3.6.1.4.1.3320.101.201.1.1.1.8ColumnramUsageHighLimitClearThresholdread-writemandatoryThe upper threshold of RAM usage alarm cleared. The range is 1-100. Default is 100.
1.3.6.1.4.1.3320.101.201.1.1.1.9ColumnramUsageHighLimitRowStatusread-createmandatoryThe row status of RAM usage alarm .
1.3.6.1.4.1.3320.101.201.1.1.1.10ColumntemperatureAlarmUpLimitEnableread-writemandatoryEnable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.201.1.1.1.11ColumntemperatureAlarmUpLimitThresholdread-writemandatoryThe upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
1.3.6.1.4.1.3320.101.201.1.1.1.12ColumntemperatureAlarmUpLimitClearThresholdread-writemandatoryThe upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
1.3.6.1.4.1.3320.101.201.1.1.1.13ColumntemperatureAlarmUpLimitRowStatusread-createmandatoryThe row status of temperature upper alarm.
1.3.6.1.4.1.3320.101.201.1.1.1.14ColumntemperatureAlarmLowLimitEnableread-writemandatoryEnable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.201.1.1.1.15ColumntemperatureAlarmLowLimitThresholdread-writemandatoryThe low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
1.3.6.1.4.1.3320.101.201.1.1.1.16ColumntemperatureAlarmLowLimitClearThresholdread-writemandatoryThe low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
1.3.6.1.4.1.3320.101.201.1.1.1.17ColumntemperatureAlarmLowLimitRowStatusread-createmandatoryThe row status of temperature low alarm.
1.3.6.1.4.1.3320.101.201.1.1.1.18ColumnvoltageAlarmUpLimitEnableread-writemandatoryEnable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.201.1.1.1.19ColumnvoltageAlarmUpLimitThresholdread-writemandatoryThe upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65.
1.3.6.1.4.1.3320.101.201.1.1.1.20ColumnvoltageAlarmUpLimitClearThresholdread-writemandatoryThe upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65.
1.3.6.1.4.1.3320.101.201.1.1.1.21ColumnvoltageAlarmUpLimitRowStatusread-createmandatoryThe row status of voltage upper alarm.
1.3.6.1.4.1.3320.101.201.1.1.1.22ColumnvoltageAlarmLowLimitEnableread-writemandatoryEnable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable.
1.3.6.1.4.1.3320.101.201.1.1.1.23ColumnvoltageAlarmLowLimitThresholdread-writemandatoryThe low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0.
1.3.6.1.4.1.3320.101.201.1.1.1.24ColumnvoltageAlarmLowLimitClearThresholdread-writemandatoryThe low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0.
1.3.6.1.4.1.3320.101.201.1.1.1.25ColumnvoltageAlarmLowLimitRowStatusread-createmandatoryThe row status of voltage low alarm.
1.3.6.1.4.1.3320.101.201.1.2TableonuPerformParameterTablenot-accessiblemandatoryDescription.
1.3.6.1.4.1.3320.101.201.1.2.1RowonuPerformParameterEntrynot-accessiblemandatoryDescription.
1.3.6.1.4.1.3320.101.201.1.2.1.1ColumnifIndexread-writemandatoryIndex of LLID interface.
1.3.6.1.4.1.3320.101.201.1.2.1.2ColumncpuUsageread-writemandatoryCPU usage . The unit is 1%. The range is 1-100. Default is 0.
1.3.6.1.4.1.3320.101.201.1.2.1.3ColumnramUsageread-writemandatoryRAM usage. The unit is 1%. The range is 1-100. Default is 0.
1.3.6.1.4.1.3320.101.201.1.2.1.4Columntemperatureread-writemandatoryTemperature.The unit is 0.1 degree. The range is -1280-1280. Default is 0.
1.3.6.1.4.1.3320.101.201.1.2.1.5Columnvoltageread-writemandatoryVoltage.The unit is 0.1V. The range is 0-65. Default is 0.