MIB Viewer

NORTEL-OME40G-FAC-MIB

113 objects
Optical Multiservice Edge (ome) This Module will be used to identify the facility attributes for Nortel OME6500 40G facilities
Imported Objects
IF-MIBifIndex
NORTEL-OME40G-MIBnnOme40G
RFC1213-MIBDisplayString
SNMPv2-SMIMODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCRowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.562.68.11.3.1IdentitynnOme40GFacilitiesOptical Multiservice Edge (ome) This Module will be used to identify the facility attributes for Nortel OME6500 40G facilities
1.3.6.1.4.1.562.68.11.3.1.1NodennOCn
1.3.6.1.4.1.562.68.11.3.1.1.1TablennOCnTablenot-accessiblecurrentContains entries for OC192 and OC768 facilities
1.3.6.1.4.1.562.68.11.3.1.1.1.1RownnOCnEntrynot-accessiblecurrentThis entry shall contain all the necessary attributes for the OC768 and OC192 facilities in the 40G card
1.3.6.1.4.1.562.68.11.3.1.1.1.1.1ColumnocnRowStatusread-writecurrentThis attribute is used to manage rows in the facility entry
1.3.6.1.4.1.562.68.11.3.1.1.1.1.2ColumnstFormatread-writecurrentSection trace format
1.3.6.1.4.1.562.68.11.3.1.1.1.1.3ColumnexpSTrcread-writecurrentExpected section trace
1.3.6.1.4.1.562.68.11.3.1.1.1.1.4ColumnstfModeread-writecurrentSection trace alarming mode
1.3.6.1.4.1.562.68.11.3.1.1.1.1.5ColumneBerThread-onlycurrentExcessive Bit rate threshold
1.3.6.1.4.1.562.68.11.3.1.1.1.1.6ColumnocnPortModeread-writecurrentPort mode can eithter be SONET or SDH
1.3.6.1.4.1.562.68.11.3.1.1.1.1.7ColumnocnLaserOffFarEndFailread-writecurrentIt can either be Enabled or Disabled.
1.3.6.1.4.1.562.68.11.3.1.1.1.1.8ColumnoChTxActOcnPwrread-onlycurrentActual Optical Channel transmit power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
1.3.6.1.4.1.562.68.11.3.1.1.1.1.9ColumnoChTxMinOcnPwrread-onlycurrentMinimum Optical Channel transmit power
1.3.6.1.4.1.562.68.11.3.1.1.1.1.10ColumnoChTxMaxOcnPwrread-onlycurrentMaximum Optical Channel transmit power
1.3.6.1.4.1.562.68.11.3.1.1.1.1.11ColumnoChRxActOcnPwrread-onlycurrentActual Optical Channel receive power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
1.3.6.1.4.1.562.68.11.3.1.1.1.1.12ColumnoChRxMinOcnPwrread-onlycurrentMinimum Optical Channel receive power.
1.3.6.1.4.1.562.68.11.3.1.1.1.1.13ColumnoChRxMaxOcnPwrread-onlycurrentMaximum Optical Channel receive power.
1.3.6.1.4.1.562.68.11.3.1.1.1.1.14ColumnexpSectionTraceMsgread-onlycurrentExpected section trace message. This variable contains data during GET operations only. GET-NEXT returns No Assigned Value
1.3.6.1.4.1.562.68.11.3.1.1.1.1.15ColumnincSectionTraceMsgread-onlycurrentIncoming section trace message This variable contains data during GET operations only. GET-NEXT returns No Assigned Value
1.3.6.1.4.1.562.68.11.3.1.1.1.1.16ColumnocnLoopbackTyperead-writecurrentNothing is returned if Loopback is not active; otherwise the facility is returned.
1.3.6.1.4.1.562.68.11.3.1.1.1.1.17ColumnocnPrimaryStateread-onlycurrentPrimary State of the faciltiy. Can only be modified by changing the admin state.
1.3.6.1.4.1.562.68.11.3.1.1.1.1.18ColumnocnSecondaryStateread-onlycurrentSecondary state for the facility. A facility can have more than one secondary state as different combinations of the individual secondary state. It is represen…
1.3.6.1.4.1.562.68.11.3.1.1.1.1.19ColumnocnAdminStateread-writecurrentThis is a write-only variable. The user can restore or remove facilities using this command. You restore a facility by setting this variable to IS and remove i…
1.3.6.1.4.1.562.68.11.3.1.1.1.1.20ColumnocnAIDread-onlycurrentFacility AID as received from TL1. This should include the FAC type, shelf id, slot, and port.
1.3.6.1.4.1.562.68.11.3.1.2NodennOTMn
1.3.6.1.4.1.562.68.11.3.1.2.1TablennOTMnTablenot-accessiblecurrentContains entries for the OTM2/3 facilities
1.3.6.1.4.1.562.68.11.3.1.2.1.1RownnOTMnEntrynot-accessiblecurrentAn Entry for the OTM2/3 facilities
1.3.6.1.4.1.562.68.11.3.1.2.1.1.1ColumnotmRowStatusread-writecurrentUsed to create/delete, put in service and out of service, and edit.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.2Columnosidread-writecurrentOptical Service ID
1.3.6.1.4.1.562.68.11.3.1.2.1.1.3ColumnotuTxFecFmtread-writecurrentOTU transmit FEC format
1.3.6.1.4.1.562.68.11.3.1.2.1.1.4ColumnotuRxFecFmtread-writecurrentOTU receive FEC format
1.3.6.1.4.1.562.68.11.3.1.2.1.1.5ColumnoduTermread-onlycurrentIndicates whether or not ODU TTI is terminated on this OTMn facility. Possible values are ODUTTITERM for OTM2 or ODUTERM for OTM3.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.6ColumnotuTxTTIread-writecurrentOTU transmit trail trace identifier.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.7ColumnoduTxTTIread-writecurrentODU transmit trail trace identifier.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.8ColumnotuRxExpTTIread-writecurrentOTU receive trail trace identifier.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.9ColumnoduRxExpTTIread-writecurrentODU receive trail trace identifer.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.10ColumntxPathIdread-writecurrentTransmit path identifier
1.3.6.1.4.1.562.68.11.3.1.2.1.1.11ColumnoChTxPwrread-writecurrentProvisioned output power
1.3.6.1.4.1.562.68.11.3.1.2.1.1.12ColumnoChTxActOtmPwrread-onlycurrentActual optical channel transmit power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.13ColumnoChTxMinOtmPwrread-onlycurrentMinimum transmit power.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.14ColumnoChTxMaxOtmPwrread-onlycurrentMaximum transmit power.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.15ColumnoChRxActOtmPwrread-onlycurrentActual receive power This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.16ColumnoChRxMinOtmPwrread-onlycurrentMinimum receive power
1.3.6.1.4.1.562.68.11.3.1.2.1.1.17ColumnoChRxMaxOtmPwrread-onlycurrentMaximum receive power
1.3.6.1.4.1.562.68.11.3.1.2.1.1.18ColumnoChTxWvlngthProvread-writecurrentProvisioned transmit wavelength
1.3.6.1.4.1.562.68.11.3.1.2.1.1.19ColumnoChTxWvlngthMinread-onlycurrentMinimum transmit wavelength
1.3.6.1.4.1.562.68.11.3.1.2.1.1.20ColumnoChTxWvlngthMaxread-onlycurrentMaximum Transmit wavelength
1.3.6.1.4.1.562.68.11.3.1.2.1.1.21ColumnoChTxWvlngthSpacingread-onlycurrentTransmit wavelength spacing
1.3.6.1.4.1.562.68.11.3.1.2.1.1.22ColumnoChRxActDispread-onlycurrentActual receive dispersion. Data for this variable is only available from the subtending card. This data is retrieved from the SP with GET-NEXT. When there is n…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.23ColumnoChRxActPmdread-onlycurrentActual receive polarization mode dispersion (PMD) This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.24ColumnoChRxPmdMaxread-onlycurrentMaximum receive PMD
1.3.6.1.4.1.562.68.11.3.1.2.1.1.25ColumnoChRxEchoTraceread-onlycurrentData for this variable is only available from the subtending card. This data is retrieved from the SP with GET-NEXT. When there is no real-hardware the GET req…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.26ColumnoChTxTraceread-onlycurrentData for this variable is only available from the subtending card. This data is retrieved from the SP with GET-NEXT. When there is no real-hardware the GET req…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.27ColumnoChTxAssocFarEndRxread-onlycurrentData for this variable is only available from the subtending card. This data is retrieved from the SP with GET-NEXT. When there is no real-hardware the GET req…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.28ColumnotmPortModeread-writecurrent
1.3.6.1.4.1.562.68.11.3.1.2.1.1.29ColumntfModeread-writecurrentTrace alarm mode
1.3.6.1.4.1.562.68.11.3.1.2.1.1.30ColumnoduTfModeread-writecurrentODU trace alarm enable/disable
1.3.6.1.4.1.562.68.11.3.1.2.1.1.31ColumnotmLaserOffFarEndFailread-writecurrentAlways enabled in Release 5.1
1.3.6.1.4.1.562.68.11.3.1.2.1.1.32ColumnpreFecSigFailThreshLevelread-writecurrentPre FEC Signal Fail Threshold Level
1.3.6.1.4.1.562.68.11.3.1.2.1.1.33ColumnotuSignalDegradeThreshLevelread-onlycurrentOTU Signal Degrade Threshold Level
1.3.6.1.4.1.562.68.11.3.1.2.1.1.34ColumnoduMonitorEnabledread-onlycurrentBeware of overloading ODUMONITOR in RTRV-TTI and RTRV-OTM3
1.3.6.1.4.1.562.68.11.3.1.2.1.1.35ColumnlineRateread-createcurrentLine Rate to be specified at create time only.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.36ColumnotuExpTTIread-onlycurrentExpected incoming OTU TTI message. This variable is not available during table view, walk, or any get-next operation. It only has data on specific GET requsets…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.37ColumnotuRxIncTTIread-onlycurrentReceive OTU TTI message This variable is not available during table view, walk, or any get-next operation. It only has data on specific GET requsets to the fac…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.38ColumnoduRxIncTTIread-onlycurrentReceive ODU TTI message This variable is not available during table view, walk, or any get-next operation. It only has data on specific GET requsets to the fac…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.39ColumnoduMonitorMsgread-onlycurrentODU monitoring message This variable is not available during table view, walk, or any get-next operation. It only has data on specific GET requsets to the faci…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.40ColumnotmLoopbackTyperead-writecurrentFacility if loopback is active; otherwise, nothing is returned for this attribute
1.3.6.1.4.1.562.68.11.3.1.2.1.1.41Columnopu2reservedread-onlycurrentYES/NO to using 7 overhead bytes for payload
1.3.6.1.4.1.562.68.11.3.1.2.1.1.42ColumnexpectedPayloadTyperead-writecurrentThis is received as a HEX value from TL1. The ranges are 0..FF. Since HEX can not be represented in ASN.1, a string is used. For SET operations, the user can e…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.43ColumntransmittedPayloadTyperead-writecurrentThis is received as a HEX value from TL1. The ranges are 0..FF. Since HEX can not be represented in ASN.1, a string is used. For SET operations, the user can e…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.44ColumnreceivedPayloadTyperead-onlycurrentThis is received as a HEX value from TL1. The ranges are 0..FF. Since HEX can not be represented in ASN.1, a string is used. This variable is available upon GE…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.45ColumnotmPrimaryStateread-onlycurrentPrimary State of the faciltiy. Can only be modified by changing the admin state.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.46ColumnotmSecondaryStateread-onlycurrentSecondary state for the facility. A facility can have more than one secondary state as different combinations of the individual secondary state. It is represen…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.47ColumnotmAdminStateread-writecurrentThis is a write-only variable. The user can restore or remove facilities using this command. You restore a facility by setting this variable to IS and remove i…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.48ColumnotmAIDread-onlycurrentFacility AID as received from TL1. This should include the FAC type, shelf id, slot, and port.
1.3.6.1.4.1.562.68.11.3.1.2.1.1.49ColumnotmGCCread-writecurrentA Get operation on this variable retrieves the LLSDCC Carrier GCC value. Setting this variable to NONE removes OSPF circuit and LLSDCC carrier info. It is a NO…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.50ColumnospfCircuitread-writecurrentWith GET operations, this variable shall return the configured parameters of the OSPF circuit. In this release only the NETAREA is supported. With SET operatio…
1.3.6.1.4.1.562.68.11.3.1.2.1.1.51ColumnoChDifferentialEncodingread-writecurrent
1.3.6.1.4.1.562.68.11.3.1.3NodennEth
1.3.6.1.4.1.562.68.11.3.1.3.1TablennEthTablenot-accessiblecurrentContains entries for ethernet 10G facilities
1.3.6.1.4.1.562.68.11.3.1.3.1.1RownnEthEntrynot-accessiblecurrentThis entry shall contain all the necessary attributes for the ethernet 10G facilities in the 40G card
1.3.6.1.4.1.562.68.11.3.1.3.1.1.1ColumnethRowStatusread-writecurrentCreate, delete, put in service, out of service, and edit
1.3.6.1.4.1.562.68.11.3.1.3.1.1.2ColumnethLaserOffFarEndFailread-writecurrentTo turn off Tx laser under certain failure scenarios
1.3.6.1.4.1.562.68.11.3.1.3.1.1.3ColumnoChTxActEthPwrread-onlycurrentThe target will be of the format xx.x and dBm will be assumed for powers within design/accuracy range. Powers outside the accuracy/design range will be clamped…
1.3.6.1.4.1.562.68.11.3.1.3.1.1.4ColumnoChTxMinEthPwrread-onlycurrentThe target will be of the format xx.x and dBm will be assumed
1.3.6.1.4.1.562.68.11.3.1.3.1.1.5ColumnoChTxMaxEthPwrread-onlycurrentThe target will be of the format xx.x and dBm will be assumed
1.3.6.1.4.1.562.68.11.3.1.3.1.1.6ColumnoChRxActEthPwrread-onlycurrentThe target will be of the format xx.x and dBm will be assumed for powers within design/accuracy range. Powers outside the accuracy/design range will be clamped…
1.3.6.1.4.1.562.68.11.3.1.3.1.1.7ColumnoChRxMinEthPwrread-onlycurrentThe target will be of the format xx.x and dBm will be assumed
1.3.6.1.4.1.562.68.11.3.1.3.1.1.8ColumnoChRxMaxEthPwrread-onlycurrentThe target will be of the format xx.x and dBm will be assumed
1.3.6.1.4.1.562.68.11.3.1.3.1.1.9ColumnmaxTransUnitread-writecurrentMaximum transmission unit
1.3.6.1.4.1.562.68.11.3.1.3.1.1.10ColumnflowControlread-writecurrent
1.3.6.1.4.1.562.68.11.3.1.3.1.1.11Columnequipmentread-writecurrent
1.3.6.1.4.1.562.68.11.3.1.3.1.1.12ColumnethMappingread-createcurrentSets the non-client OTM2 OTU rate and client mapping
1.3.6.1.4.1.562.68.11.3.1.3.1.1.13ColumnethLoopbackTyperead-writecurrentFacility if loopback is active; otherwise nothing is returned for this attribute.
1.3.6.1.4.1.562.68.11.3.1.3.1.1.14ColumnethPrimaryStateread-onlycurrentPrimary State of the faciltiy. Can only be modified by changing the admin state.
1.3.6.1.4.1.562.68.11.3.1.3.1.1.15ColumnethSecondaryStateread-onlycurrentSecondary state for the facility. A facility can have more than one secondary state as different combinations of the individual secondary state. It is represen…
1.3.6.1.4.1.562.68.11.3.1.3.1.1.16ColumnethAdminStateread-writecurrentThis is a write-only variable. The user can restore or remove facilities using this command. You restore a facility by setting this variable to IS and remove i…
1.3.6.1.4.1.562.68.11.3.1.3.1.1.17ColumnethAIDread-onlycurrentFacility AID as received from TL1. This should include the FAC type, shelf id, slot, and port.
1.3.6.1.4.1.562.68.11.3.1.4NodennWAN
1.3.6.1.4.1.562.68.11.3.1.4.1TablennWanTablenot-accessiblecurrentContains entries for ethernet 10G facilities
1.3.6.1.4.1.562.68.11.3.1.4.1.1RownnWanEntrynot-accessiblecurrentThis entry shall contain all the necessary attributes for the ethernet 10G facilities in the 40G card
1.3.6.1.4.1.562.68.11.3.1.4.1.1.1ColumnframeChecksumread-writecurrentFor mapping=GFP-F, value can be 0 or 32
1.3.6.1.4.1.562.68.11.3.1.4.1.1.2ColumnwanMappingread-writecurrentGFP-F is only supported value
1.3.6.1.4.1.562.68.11.3.1.4.1.1.3ColumngfpRfiread-writecurrentEnable/Disable
1.3.6.1.4.1.562.68.11.3.1.4.1.1.4ColumngfpRtDelayread-writecurrentEnable/Disable
1.3.6.1.4.1.562.68.11.3.1.4.1.1.5ColumncondTyperead-writecurrentGFP CMF is the only supported value.
1.3.6.1.4.1.562.68.11.3.1.4.1.1.6Columnpreambleread-writecurrentKEEP/DISCARD ethernet preamble
1.3.6.1.4.1.562.68.11.3.1.4.1.1.7ColumnfcsErrFramesread-writecurrentKEEP/DISCARD FCS-errored frames end-to-end.
1.3.6.1.4.1.562.68.11.3.1.4.1.1.8ColumntransmittedUPIread-writecurrentThis is received as a HEX value from TL1. The ranges are 0..FF. Since HEX can not be represented in ASN.1, a string is used. For SET operations, the user can e…
1.3.6.1.4.1.562.68.11.3.1.4.1.1.9ColumnwanPrimaryStateread-onlycurrentPrimary State of the faciltiy. Can only be modified by changing the admin state.
1.3.6.1.4.1.562.68.11.3.1.4.1.1.10ColumnwanSecondaryStateread-onlycurrentSecondary state for the facility. A facility can have more than one secondary state as different combinations of the individual secondary state. It is represen…
1.3.6.1.4.1.562.68.11.3.1.4.1.1.11ColumnwanAdminStateread-writecurrentThis is a write-only variable. The user can restore or remove facilities using this command. You restore a facility by setting this variable to IS and remove i…
1.3.6.1.4.1.562.68.11.3.1.4.1.1.12ColumnwanAIDread-onlycurrentFacility AID as received from TL1. This should include the FAC type, shelf id, slot, and port.