MIB Viewer

NORTEL-OME40G-PM-PROV-MIB

20 objects
On Optical Multiservice Edge (OME), this module is used to initialize 40G PM registers and OM Counts. It is also used to set Threshold Level and HccsReference Values, and change Profiles for 40G facilities.
Imported Objects
IF-MIBifIndex
NORTEL-OME40G-MIBnnOme40G
RFC1213-MIBDisplayString
SNMPv2-SMIMODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.562.68.11.3.4IdentitynnOme40GPmProvfromOn Optical Multiservice Edge (OME), this module is used to initialize 40G PM registers and OM Counts. It is also used to set Threshold Level and HccsReference …
1.3.6.1.4.1.562.68.11.3.4.1NodennOme40GMonConfig
1.3.6.1.4.1.562.68.11.3.4.1.1TablennMonConfigTablenot-accessiblecurrent
1.3.6.1.4.1.562.68.11.3.4.1.1.1RownnMonConfigEntrynot-accessiblecurrent
1.3.6.1.4.1.562.68.11.3.4.1.1.1.1ColumnhccsReferenceread-writecurrentHigh Correction Count Seconds. Applies for OTM2/3 only. Floating point between -1.00 and 4.00; Not supported by SMI-OM5K
1.3.6.1.4.1.562.68.11.3.4.1.1.1.2Columninit40GPmRegistersread-writecurrentInitializes the counts for all montypes on the facility, if ifIndex contains ifType. If IfIndex contains only slot info, all 40G facilities on the card get res…
1.3.6.1.4.1.562.68.11.3.4.1.1.1.3Columninit40GOmCountsread-writecurrentInitializes the counts for all montypes on the facility, if ifIndex contains ifType. If IfIndex contains only slot info, all 40G facilities on the card get res…
1.3.6.1.4.1.562.68.11.3.4.1.2TablennMonTypeInstanceTablenot-accessiblecurrent
1.3.6.1.4.1.562.68.11.3.4.1.2.1RownnMonTypeInstanceEntrynot-accessiblecurrent
1.3.6.1.4.1.562.68.11.3.4.1.2.1.1ColumnmonTypenot-accessiblecurrentMonitored parm type; group of values acceptable; should act more like a bitmask
1.3.6.1.4.1.562.68.11.3.4.1.2.1.2Columnendpointnot-accessiblecurrent
1.3.6.1.4.1.562.68.11.3.4.1.2.1.3Columndirectionnot-accessiblecurrent
1.3.6.1.4.1.562.68.11.3.4.1.2.1.4ColumnaccumTimePeriodnot-accessiblecurrentAccumulation time period, group of values acceptable
1.3.6.1.4.1.562.68.11.3.4.1.2.1.5ColumnmonValread-writecurrentZero to reset or MONTYPE
1.3.6.1.4.1.562.68.11.3.4.1.2.1.6ColumnthreshLevelread-writecurrentFew Montype require scientific notation type input. e.g.:5E-10. So, this threshLevel value must be in string to support various input.
1.3.6.1.4.1.562.68.11.3.4.1.2.1.7ColumnsrcProfileIdread-writecurrent
1.3.6.1.4.1.562.68.11.3.4.1.2.1.8ColumndstProfileIdread-writecurrent
1.3.6.1.4.1.562.68.11.3.4.1.2.1.9ColumninitRegistersread-writecurrent
1.3.6.1.4.1.562.68.11.3.4.2ScalarinitShelf40GPmRegistersread-writecurrentInitializes PM registers for 40G facilities on the shelf.
1.3.6.1.4.1.562.68.11.3.4.3ScalarinitShelfEthOmCountsread-writecurrentInitiliazes Ethernet OM Counts for 40G facilities on the shelf.