NSCRTV-OSW
140 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC1155-SMI | enterprises |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.17409 | NodenscrtvRoot | |||
| 1.3.6.1.4.1.17409.1 | NodenscrtvHFCemsTree | |||
| 1.3.6.1.4.1.17409.1.0 | NodehfcColdStart | HfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after t… | ||
| 1.3.6.1.4.1.17409.1.1 | NodehfcAlarmEvent | When detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the par… | ||
| 1.3.6.1.4.1.17409.1.1 | NodepropertyIdent | |||
| 1.3.6.1.4.1.17409.1.1.1 | TableanalogPropertyTable | not-accessible | mandatory | Simulation parameters attribute table. |
| 1.3.6.1.4.1.17409.1.1.1.1 | RowanalogPropertyEntry | not-accessible | mandatory | Attribute Table simulation parameters head.OID purpose as a table index, the coding method is 'length + OID.' OID before two members of the '130' is based on '… |
| 1.3.6.1.4.1.17409.1.1.1.1.1 | ColumnanalogParameterOID | read-only | mandatory | index |
| 1.3.6.1.4.1.17409.1.1.1.1.2 | ColumnalarmEnable | read-write | mandatory | Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning Bit 0: Alarm enable low Bit 1: Alarm enable low Bit 2: Alar… |
| 1.3.6.1.4.1.17409.1.1.1.1.3 | ColumnanalogAlarmState | read-only | mandatory | The parameters of the current state of alarm. |
| 1.3.6.1.4.1.17409.1.1.1.1.4 | ColumnanalogAlarmHIHI | read-write | mandatory | The parameters of the current state of alarm. |
| 1.3.6.1.4.1.17409.1.1.1.1.5 | ColumnanalogAlarmHI | read-write | mandatory | HI high alarm threshold value. This object should be stored in non-volatile memory |
| 1.3.6.1.4.1.17409.1.1.1.1.6 | ColumnanalogAlarmLO | read-write | mandatory | LO low alarm threshold value. This object should be stored in nonvolatile memory |
| 1.3.6.1.4.1.17409.1.1.1.1.7 | ColumnanalogAlarmLOLO | read-write | mandatory | Alarm LOLO very low threshold value. This object should be stored in nonvolatile memory. |
| 1.3.6.1.4.1.17409.1.1.1.1.8 | ColumnanalogAlarmDeadband | read-write | mandatory | Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the ab… |
| 1.3.6.1.4.1.17409.1.1.2 | TablediscretePropertyTable | not-accessible | mandatory | Discrete Attribute Table |
| 1.3.6.1.4.1.17409.1.1.2.1 | RowdiscretePropertyEntry | not-accessible | mandatory | Attribute Table discrete head. OID coding methods with simulation attribute table. |
| 1.3.6.1.4.1.17409.1.1.2.1.1 | ColumndiscreteParameterOID | read-only | mandatory | Attribute Table discrete index 1: Parameters OID |
| 1.3.6.1.4.1.17409.1.1.2.1.2 | ColumndiscreteAlarmValue | read-only | mandatory | Attribute Table discrete index 2: parameter values.When the equipment value of this parameter values, and so will be dealt with a warning |
| 1.3.6.1.4.1.17409.1.1.2.1.3 | ColumndiscreteAlarmEnable | read-write | mandatory | When the alarm so that it can open the (2 or 3), this parameter allows for alarm processin If the alarm so that it can shut down (1), alarm processing will be … |
| 1.3.6.1.4.1.17409.1.1.2.1.4 | ColumndiscreteAlarmState | read-only | mandatory | The parameters of the current state of alarm |
| 1.3.6.1.4.1.17409.1.1.3 | TablecurrentAlarmTable | not-accessible | mandatory | The current alarm table. |
| 1.3.6.1.4.1.17409.1.1.3.1 | RowcurrentAlarmEntry | not-accessible | mandatory | The current warning Table Head. OID coding methods with simulation attribute table |
| 1.3.6.1.4.1.17409.1.1.3.1.1 | ColumncurrentAlarmOID | read-only | mandatory | NE, currently in a state of alarm parameters OID Index, and the alarm in the table attribute parameters OID counterparts. |
| 1.3.6.1.4.1.17409.1.1.3.1.2 | ColumncurrentAlarmState | read-only | mandatory | Warning parameters of the current state of alarm |
| 1.3.6.1.4.1.17409.1.1.3.1.3 | ColumncurrentAlarmValue | read-only | mandatory | Alarm parameter values. |
| 1.3.6.1.4.1.17409.1.2 | NodealarmsIdent | |||
| 1.3.6.1.4.1.17409.1.2 | NodehfcWarmStart | HfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after th… | ||
| 1.3.6.1.4.1.17409.1.2.1 | ScalaralarmLogNumberOfEntries | read-only | mandatory | Alarm record number of records in the table |
| 1.3.6.1.4.1.17409.1.2.2 | ScalaralarmLogLastIndex | read-only | mandatory | Recently a warning the index of the records. |
| 1.3.6.1.4.1.17409.1.2.3 | TablealarmLogTable | not-accessible | mandatory | Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps ne… |
| 1.3.6.1.4.1.17409.1.2.3.1 | RowalarmLogEntry | not-accessible | mandatory | Alarm Sheet Head |
| 1.3.6.1.4.1.17409.1.2.3.1.1 | ColumnalarmLogIndex | read-only | mandatory | The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32767, under a record index o… |
| 1.3.6.1.4.1.17409.1.2.3.1.2 | ColumnalarmLogInformation | read-only | mandatory | Alarm record information, multi-byte strings, defined as follows: Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte) Byte 5: Alarm types (enum… |
| 1.3.6.1.4.1.17409.1.2.4 | ScalaralarmText | not-accessible | optional | This trap targets for the needs of information contained in a text field transponder information is achievable.The field contains the text of the object depend… |
| 1.3.6.1.4.1.17409.1.3 | NodecommonIdent | |||
| 1.3.6.1.4.1.17409.1.3.1 | NodecommonAdminGroup | |||
| 1.3.6.1.4.1.17409.1.3.1.1 | ScalarcommonNELogicalID | read-write | mandatory | The logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE.This target value should be stored in non-volatile memory |
| 1.3.6.1.4.1.17409.1.3.1.2 | ScalarcommonNEVendor | read-only | mandatory | NE equipment manufacturers�� |
| 1.3.6.1.4.1.17409.1.3.1.3 | ScalarcommonNEModelNumber | read-only | mandatory | |
| 1.3.6.1.4.1.17409.1.3.1.4 | ScalarcommonNESerialNumber | read-only | mandatory | NE equipment serial numbers |
| 1.3.6.1.4.1.17409.1.3.1.5 | ScalarcommonNEVendorInfo | read-only | optional | NE equipment suppliers other special designated information |
| 1.3.6.1.4.1.17409.1.3.1.6 | ScalarcommonNEStatus | read-only | mandatory | With 7.5.4 STATRESP PDU in the corresponding parameters Status Bit 0: CHNLRQST Bit 1: CNTNRM Bit 2: CNTCUR Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD1… |
| 1.3.6.1.4.1.17409.1.3.1.7 | ScalarcommonReset | read-write | mandatory | Write'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', the equipment had no effect�� |
| 1.3.6.1.4.1.17409.1.3.1.8 | ScalarcommonAlarmDetectionControl | read-write | mandatory | This object used to control the Alarm Detection NE.When the attribute table or discrete simulation attribute table MIB objects to a set threshold, that alarm h… |
| 1.3.6.1.4.1.17409.1.3.1.9 | ScalarcommonNetworkAddress | read-only | mandatory | NE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the… |
| 1.3.6.1.4.1.17409.1.3.1.10 | ScalarcommonCheckCode | read-write | mandatory | This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment… |
| 1.3.6.1.4.1.17409.1.3.1.11 | ScalarcommonTrapCommunityString | read-write | mandatory | Definition of Community Trap string. The default value is' public ' |
| 1.3.6.1.4.1.17409.1.3.1.12 | ScalarcommonTamperStatus | read-only | optional | The safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in … |
| 1.3.6.1.4.1.17409.1.3.1.13 | ScalarcommonInternalTemperature | read-only | optional | NE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table |
| 1.3.6.1.4.1.17409.1.3.1.14 | ScalarcommonTime | read-write | optional | NE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds). |
| 1.3.6.1.4.1.17409.1.3.1.15 | ScalarcommonVarBindings | read-only | mandatory | This object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number… |
| 1.3.6.1.4.1.17409.1.3.1.16 | ScalarcommonResetCause | read-only | mandatory | NE said the reasons for the recent reduction. |
| 1.3.6.1.4.1.17409.1.3.1.17 | ScalarcommonCraftStatus | read-only | mandatory | NE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface w… |
| 1.3.6.1.4.1.17409.1.3.1.18 | ScalarcommonDeviceOID | read-only | optional | This OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc.). |
| 1.3.6.1.4.1.17409.1.3.1.19 | ScalarcommonDeviceId | read-only | optional | The contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages |
| 1.3.6.1.4.1.17409.1.3.2 | NodecommonAdminUseRf | |||
| 1.3.6.1.4.1.17409.1.3.2.1 | NodecommonMACGroup | |||
| 1.3.6.1.4.1.17409.1.3.2.1.1 | NodecommonMacAddress | |||
| 1.3.6.1.4.1.17409.1.3.2.1.1.1 | ScalarcommonPhysAddress | read-only | mandatory | NE physical address |
| 1.3.6.1.4.1.17409.1.3.2.1.1.2 | ScalarcommonMaxMulticastAddresses | read-only | mandatory | NE equipment to support the greatest number of multicast addresses. |
| 1.3.6.1.4.1.17409.1.3.2.1.1.3 | TablecommonMulticastAddressTable | not-accessible | mandatory | Multicast addresses Table, the value of this object should be stored in nonvolatile memory. |
| 1.3.6.1.4.1.17409.1.3.2.1.1.3.1 | RowcommonMulticastAddressEntry | not-accessible | mandatory | Multicast addresses head table. |
| 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.1 | ColumncommonMulticastAddressIndex | read-only | mandatory | Multicast addresses head table. |
| 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.2 | ColumncommonMulticastAddressNumber | read-write | mandatory | Multicast address, I / G-1 effective. |
| 1.3.6.1.4.1.17409.1.3.2.1.2 | NodecommonBackoffParams | |||
| 1.3.6.1.4.1.17409.1.3.2.1.2.1 | ScalarcommonBackoffPeriod | read-write | mandatory | Backoff algorithm benchmark time (ms), initialize the default value of 6 ms.The value of this object should be stored in nonvolatile memory. |
| 1.3.6.1.4.1.17409.1.3.2.1.2.2 | ScalarcommonACKTimeoutWindow | read-write | mandatory | NE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms.The value of this object should be stored in nonvolatile memory. |
| 1.3.6.1.4.1.17409.1.3.2.1.2.3 | ScalarcommonMaximumMACLayerRetries | read-write | mandatory | NE data packets sent the greatest number of re-examination. Initialize the default value is 16.The value of this object should be stored in nonvolatile memory. |
| 1.3.6.1.4.1.17409.1.3.2.1.2.4 | ScalarcommonMaxPayloadSize | read-only | mandatory | From top to bottom line channel packet supported by the largest payload (payload) the length of |
| 1.3.6.1.4.1.17409.1.3.2.1.2.5 | ScalarcommonBackoffMinimumExponent | read-write | mandatory | The standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6.This value may not exceed comm… |
| 1.3.6.1.4.1.17409.1.3.2.1.2.6 | ScalarcommonBackoffMaximumExponent | read-write | mandatory | The body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15.This value shall be not l… |
| 1.3.6.1.4.1.17409.1.3.2.1.3 | NodecommonMacStats | |||
| 1.3.6.1.4.1.17409.1.3.2.1.3.1 | ScalarcommonForwardPathLOSEvents | read-write | optional | LOS downlink channel in the number of reset to 0. |
| 1.3.6.1.4.1.17409.1.3.2.1.3.2 | ScalarcommonForwardPathFramingErrors | read-write | optional | Downlink Channel frames wrong number reset to 0. |
| 1.3.6.1.4.1.17409.1.3.2.1.3.3 | ScalarcommonForwardPathCRCErrors | read-write | optional | CRC errors down the number of reset to 0. |
| 1.3.6.1.4.1.17409.1.3.2.1.3.4 | ScalarcommonInvalidMacCmds | read-write | optional | Invalid MAC layer order wrong number reset to 0. |
| 1.3.6.1.4.1.17409.1.3.2.1.3.5 | ScalarcommonBackwardPathCollisionTimes | read-write | optional | Uplink Packet collision frequency, reset to 0. |
| 1.3.6.1.4.1.17409.1.3.2.2 | NodecommonRfGroup | |||
| 1.3.6.1.4.1.17409.1.3.2.2.1 | ScalarcommonReturnPathFrequency | read-only | mandatory | Channel uplink frequency units Hz.The value of this object should be stored in non-volatile memory |
| 1.3.6.1.4.1.17409.1.3.2.2.2 | ScalarcommonForwardPathFrequency | read-only | mandatory | Downlink frequency channel, flat Hz.The value of this object should be stored in nonvolatile memory. |
| 1.3.6.1.4.1.17409.1.3.2.2.3 | ScalarcommonProvisionedReturnPowerLevel | read-write | mandatory | Upstream channel power levels and units for dBuV.When the internal use of this value will be rounded to the nearest support value. Reading return to this subje… |
| 1.3.6.1.4.1.17409.1.3.2.2.4 | ScalarcommonForwardPathReceiveLevel | read-only | optional | Downlink Channel receive power levels, units dBuV. |
| 1.3.6.1.4.1.17409.1.3.2.2.5 | ScalarcommonMaxReturnPower | read-write | mandatory | The largest upstream channel power levels and units for dBuV.The value of this object should be stored in nonvolatile memory. |
| 1.3.6.1.4.1.17409.1.3.3 | NodecommonAdminUseEthernet | |||
| 1.3.6.1.4.1.17409.1.3.3.1 | NodecommonAgentGroup | |||
| 1.3.6.1.4.1.17409.1.3.3.1.1 | ScalarcommonAgentBootWay | read-write | mandatory | |
| 1.3.6.1.4.1.17409.1.3.3.1.2 | ScalarcommonAgentReset | read-write | mandatory | Acting Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had… |
| 1.3.6.1.4.1.17409.1.3.3.1.3 | ScalarcommonAgentMaxTraps | read-write | mandatory | Acting detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values |
| 1.3.6.1.4.1.17409.1.3.3.1.4 | ScalarcommonAgentTrapMinInterval | read-write | mandatory | Acting TRAP send the minimum spacing units |
| 1.3.6.1.4.1.17409.1.3.3.1.5 | ScalarcommonAgentTrapMaxInterval | read-write | mandatory | Acting TRAP send the largest spacing units for |
| 1.3.6.1.4.1.17409.1.3.3.1.6 | ScalarcommonTrapAck | read-write | optional | The variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the va… |
| 1.3.6.1.4.1.17409.1.3.3.1.7 | TablecommonAgentTrapTable | not-accessible | mandatory | Acting Information Table TRAP |
| 1.3.6.1.4.1.17409.1.3.3.1.7.1 | RowcommonAgentTrapEntry | not-accessible | mandatory | Acting Head TRAP Information Table |
| 1.3.6.1.4.1.17409.1.3.3.1.7.1.1 | ColumncommonAgentTrapIndex | read-only | mandatory | TRAP Table Index |
| 1.3.6.1.4.1.17409.1.3.3.1.7.1.2 | ColumncommonAgentTrapIP | read-write | mandatory | When the purpose of the TRAP host's IP address |
| 1.3.6.1.4.1.17409.1.3.3.1.7.1.3 | ColumncommonAgentTrapCommunity | read-write | mandatory | Send the Community string TRAP |
| 1.3.6.1.4.1.17409.1.3.3.1.7.1.4 | ColumncommonAgentTrapStatus | read-write | mandatory | It said that the opening of TRAP |
| 1.3.6.1.4.1.17409.1.3.3.2 | NodecommonDeviceGroup | |||
| 1.3.6.1.4.1.17409.1.3.3.2.1 | ScalarcommonDeviceNum | read-write | mandatory | The agent said that the current management is the number of devices |
| 1.3.6.1.4.1.17409.1.3.3.2.2 | TablecommonDeviceInfoTable | not-accessible | mandatory | Acting is currently public information management equipment list. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1 | RowcommonDeviceInfoEntry | not-accessible | mandatory | Acting is currently public information management equipment list Table Head. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.1 | ColumncommonDeviceSlot | read-only | mandatory | Acting is currently under the management of the equipment list of public information table index. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.2 | ColumncommonDevicesID | read-only | mandatory | Designated equipment manufacturers logo |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.3 | ColumncommonDeviceVendor | read-only | mandatory | Equipment manufacturers |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.4 | ColumncommonDeviceModelNumber | read-only | mandatory | Equipment models. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.5 | ColumncommonDeviceSerialNumber | read-only | mandatory | The string of equipment. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.6 | ColumncommonDeviceVendorInfo | read-only | optional | Equipment suppliers of other special designated information |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.7 | ColumncommonDeviceStatus | read-only | mandatory | Bit 0: RSVD0 Bit 1: RSVD1 Bit 2: RSVD2 Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD5 Bit 6: RSVD6 Bit 7: RSVD7 |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.8 | ColumncommonDeviceReset | read-write | mandatory | Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', the equipment had no effect. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.9 | ColumncommonDeviceAlarmDetectionControl | read-write | mandatory | This object used to control equipment alarm detection. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.10 | ColumncommonDeviceMACAddress | read-only | mandatory | Equipment MAC address |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.11 | ColumncommonDeviceTamperStatus | read-only | optional | Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the… |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.12 | ColumncommonDeviceInternalTemperature | read-only | optional | Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.13 | ColumncommonDeviceResetCause | read-only | mandatory | Equipment that the reasons for the recent reduction |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.14 | ColumncommonDeviceCraftStatus | read-only | mandatory | This object interface that local equipment (such as RS232 or RS485 interface) state. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.15 | ColumncommonDevicesOID | read-only | mandatory | Goals identifier string, point to a concrete realization of the equipment |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.16 | ColumncommonDeviceAcct | read-only | optional | Equipment that the accumulated work time, units of s |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.17 | ColumncommonDeviceName | read-only | mandatory | Equipment name |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.18 | ColumncommonDeviceMFD | read-only | mandatory | Equipment manufacturing date. |
| 1.3.6.1.4.1.17409.1.3.3.2.2.1.19 | ColumncommonDeviceFW | read-only | mandatory | Equipment firmware information |
| 1.3.6.1.4.1.17409.1.15 | NodeoswIdent | |||
| 1.3.6.1.4.1.17409.1.15.1 | ScalaroswVendorOID | read-only | optional | This object provides manufacturers of optical switch MIB expansion. Without the expansion, this should be targeting at the optical switch nodes oswIdent |
| 1.3.6.1.4.1.17409.1.15.2 | ScalaroswMode | read-write | mandatory | The work modes of the optical switch:'1' indicates the switch choose route B��'2' indicates the switch choose route A��'3' indicates the switch choose … |
| 1.3.6.1.4.1.17409.1.15.3 | ScalaroswSwitch | read-write | mandatory | Optical switch breaking point |
| 1.3.6.1.4.1.17409.1.15.4 | TableoswChannelTable | not-accessible | mandatory | Optical Switch Information Table |
| 1.3.6.1.4.1.17409.1.15.4.1 | RowoswChannelEntry | not-accessible | mandatory | Optical Switch Information Table Head |
| 1.3.6.1.4.1.17409.1.15.4.1.1 | ColumnoswIndex | read-only | mandatory | |
| 1.3.6.1.4.1.17409.1.15.4.1.2 | ColumnoswInputA | read-only | mandatory | The input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| 1.3.6.1.4.1.17409.1.15.4.1.3 | ColumnoswInputB | read-only | mandatory | The input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| 1.3.6.1.4.1.17409.1.15.4.1.4 | ColumnoswOutput1 | read-only | mandatory | The input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| 1.3.6.1.4.1.17409.1.15.4.1.5 | ColumnoswOutput2 | read-only | mandatory | The input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| 1.3.6.1.4.1.17409.1.15.5 | ScalaroswNumberDCPowerSupply | read-only | mandatory | The number of internal DC power supply,'0 'indicates the transponder nonsupport this function. |
| 1.3.6.1.4.1.17409.1.15.6 | ScalaroswDCPowerSupplyMode | read-only | optional | Power supply work modes: Load and load-sharing, standby switch, or independency power supply. If the equipment has only one DC power supply, this should not be… |
| 1.3.6.1.4.1.17409.1.15.7 | TableoswDCPowerTable | not-accessible | mandatory | DC Power Information Table |
| 1.3.6.1.4.1.17409.1.15.7.1 | RowoswDCPowerEntry | not-accessible | mandatory | DC Power Information Table Head |
| 1.3.6.1.4.1.17409.1.15.7.1.1 | ColumnoswDCPowerIndex | read-only | mandatory | DC Power Index, table oswDCPowerTable index |
| 1.3.6.1.4.1.17409.1.15.7.1.2 | ColumnoswDCPowerVoltage | read-only | mandatory | Power supply voltage, unit in 0.1 V, this object require entry register in the attribute MIB. |
| 1.3.6.1.4.1.17409.1.15.7.1.3 | ColumnoswDCPowerCurrent | read-only | mandatory | Power supply current, unit in 0.1 A, this object require entry register in the attribute MIB. |
| 1.3.6.1.4.1.17409.1.15.7.1.4 | ColumnoswDCPowerName | read-only | mandatory | Mark Power supply name, for example: +5 V DC power supply. This field value regulated by the user, it should be marked with the number of the power supply volt… |