1.3.6.1.4.1.17409NodenscrtvRoot
1.3.6.1.4.1.17409.1NodenscrtvHFCemsTree
1.3.6.1.4.1.17409.1.0NodehfcColdStartHfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after t…
1.3.6.1.4.1.17409.1.1NodehfcAlarmEventWhen detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the par…
1.3.6.1.4.1.17409.1.1NodepropertyIdent
1.3.6.1.4.1.17409.1.1.1TableanalogPropertyTablenot-accessiblemandatorySimulation parameters attribute table.
1.3.6.1.4.1.17409.1.1.1.1RowanalogPropertyEntrynot-accessiblemandatoryAttribute Table simulation parameters head.OID purpose as a table index, the coding method is 'length + OID.' OID before two members of the '130' is based on '…
1.3.6.1.4.1.17409.1.1.1.1.1ColumnanalogParameterOIDread-onlymandatoryindex
1.3.6.1.4.1.17409.1.1.1.1.2ColumnalarmEnableread-writemandatoryAlarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning Bit 0: Alarm enable low Bit 1: Alarm enable low Bit 2: Alar…
1.3.6.1.4.1.17409.1.1.1.1.3ColumnanalogAlarmStateread-onlymandatoryThe parameters of the current state of alarm.
1.3.6.1.4.1.17409.1.1.1.1.4ColumnanalogAlarmHIHIread-writemandatoryThe parameters of the current state of alarm.
1.3.6.1.4.1.17409.1.1.1.1.5ColumnanalogAlarmHIread-writemandatoryHI high alarm threshold value. This object should be stored in non-volatile memory
1.3.6.1.4.1.17409.1.1.1.1.6ColumnanalogAlarmLOread-writemandatoryLO low alarm threshold value. This object should be stored in nonvolatile memory
1.3.6.1.4.1.17409.1.1.1.1.7ColumnanalogAlarmLOLOread-writemandatoryAlarm LOLO very low threshold value. This object should be stored in nonvolatile memory.
1.3.6.1.4.1.17409.1.1.1.1.8ColumnanalogAlarmDeadbandread-writemandatoryDead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the ab…
1.3.6.1.4.1.17409.1.1.2TablediscretePropertyTablenot-accessiblemandatoryDiscrete Attribute Table
1.3.6.1.4.1.17409.1.1.2.1RowdiscretePropertyEntrynot-accessiblemandatoryAttribute Table discrete head. OID coding methods with simulation attribute table.
1.3.6.1.4.1.17409.1.1.2.1.1ColumndiscreteParameterOIDread-onlymandatoryAttribute Table discrete index 1: Parameters OID
1.3.6.1.4.1.17409.1.1.2.1.2ColumndiscreteAlarmValueread-onlymandatoryAttribute Table discrete index 2: parameter values.When the equipment value of this parameter values, and so will be dealt with a warning
1.3.6.1.4.1.17409.1.1.2.1.3ColumndiscreteAlarmEnableread-writemandatoryWhen the alarm so that it can open the (2 or 3), this parameter allows for alarm processin If the alarm so that it can shut down (1), alarm processing will be …
1.3.6.1.4.1.17409.1.1.2.1.4ColumndiscreteAlarmStateread-onlymandatoryThe parameters of the current state of alarm
1.3.6.1.4.1.17409.1.1.3TablecurrentAlarmTablenot-accessiblemandatoryThe current alarm table.
1.3.6.1.4.1.17409.1.1.3.1RowcurrentAlarmEntrynot-accessiblemandatoryThe current warning Table Head. OID coding methods with simulation attribute table
1.3.6.1.4.1.17409.1.1.3.1.1ColumncurrentAlarmOIDread-onlymandatoryNE, currently in a state of alarm parameters OID Index, and the alarm in the table attribute parameters OID counterparts.
1.3.6.1.4.1.17409.1.1.3.1.2ColumncurrentAlarmStateread-onlymandatoryWarning parameters of the current state of alarm
1.3.6.1.4.1.17409.1.1.3.1.3ColumncurrentAlarmValueread-onlymandatoryAlarm parameter values.
1.3.6.1.4.1.17409.1.2NodealarmsIdent
1.3.6.1.4.1.17409.1.2NodehfcWarmStartHfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after th…
1.3.6.1.4.1.17409.1.2.1ScalaralarmLogNumberOfEntriesread-onlymandatoryAlarm record number of records in the table
1.3.6.1.4.1.17409.1.2.2ScalaralarmLogLastIndexread-onlymandatoryRecently a warning the index of the records.
1.3.6.1.4.1.17409.1.2.3TablealarmLogTablenot-accessiblemandatoryAlarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps ne…
1.3.6.1.4.1.17409.1.2.3.1RowalarmLogEntrynot-accessiblemandatoryAlarm Sheet Head
1.3.6.1.4.1.17409.1.2.3.1.1ColumnalarmLogIndexread-onlymandatoryThe only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32767, under a record index o…
1.3.6.1.4.1.17409.1.2.3.1.2ColumnalarmLogInformationread-onlymandatoryAlarm record information, multi-byte strings, defined as follows: Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte) Byte 5: Alarm types (enum…
1.3.6.1.4.1.17409.1.2.4ScalaralarmTextnot-accessibleoptionalThis trap targets for the needs of information contained in a text field transponder information is achievable.The field contains the text of the object depend…
1.3.6.1.4.1.17409.1.3NodecommonIdent
1.3.6.1.4.1.17409.1.3.1NodecommonAdminGroup
1.3.6.1.4.1.17409.1.3.1.1ScalarcommonNELogicalIDread-writemandatoryThe logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE.This target value should be stored in non-volatile memory
1.3.6.1.4.1.17409.1.3.1.2ScalarcommonNEVendorread-onlymandatoryNE equipment manufacturers��
1.3.6.1.4.1.17409.1.3.1.3ScalarcommonNEModelNumberread-onlymandatory
1.3.6.1.4.1.17409.1.3.1.4ScalarcommonNESerialNumberread-onlymandatoryNE equipment serial numbers
1.3.6.1.4.1.17409.1.3.1.5ScalarcommonNEVendorInforead-onlyoptionalNE equipment suppliers other special designated information
1.3.6.1.4.1.17409.1.3.1.6ScalarcommonNEStatusread-onlymandatoryWith 7.5.4 STATRESP PDU in the corresponding parameters Status Bit 0: CHNLRQST Bit 1: CNTNRM Bit 2: CNTCUR Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD1…
1.3.6.1.4.1.17409.1.3.1.7ScalarcommonResetread-writemandatoryWrite'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', the equipment had no effect��
1.3.6.1.4.1.17409.1.3.1.8ScalarcommonAlarmDetectionControlread-writemandatoryThis object used to control the Alarm Detection NE.When the attribute table or discrete simulation attribute table MIB objects to a set threshold, that alarm h…
1.3.6.1.4.1.17409.1.3.1.9ScalarcommonNetworkAddressread-onlymandatoryNE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the…
1.3.6.1.4.1.17409.1.3.1.10ScalarcommonCheckCoderead-writemandatoryThis target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment…
1.3.6.1.4.1.17409.1.3.1.11ScalarcommonTrapCommunityStringread-writemandatoryDefinition of Community Trap string. The default value is' public '
1.3.6.1.4.1.17409.1.3.1.12ScalarcommonTamperStatusread-onlyoptionalThe safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in …
1.3.6.1.4.1.17409.1.3.1.13ScalarcommonInternalTemperatureread-onlyoptionalNE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table
1.3.6.1.4.1.17409.1.3.1.14ScalarcommonTimeread-writeoptionalNE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds).
1.3.6.1.4.1.17409.1.3.1.15ScalarcommonVarBindingsread-onlymandatoryThis object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number…
1.3.6.1.4.1.17409.1.3.1.16ScalarcommonResetCauseread-onlymandatoryNE said the reasons for the recent reduction.
1.3.6.1.4.1.17409.1.3.1.17ScalarcommonCraftStatusread-onlymandatoryNE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface w…
1.3.6.1.4.1.17409.1.3.1.18ScalarcommonDeviceOIDread-onlyoptionalThis OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc.).
1.3.6.1.4.1.17409.1.3.1.19ScalarcommonDeviceIdread-onlyoptionalThe contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages
1.3.6.1.4.1.17409.1.3.2NodecommonAdminUseRf
1.3.6.1.4.1.17409.1.3.2.1NodecommonMACGroup
1.3.6.1.4.1.17409.1.3.2.1.1NodecommonMacAddress
1.3.6.1.4.1.17409.1.3.2.1.1.1ScalarcommonPhysAddressread-onlymandatoryNE physical address
1.3.6.1.4.1.17409.1.3.2.1.1.2ScalarcommonMaxMulticastAddressesread-onlymandatoryNE equipment to support the greatest number of multicast addresses.
1.3.6.1.4.1.17409.1.3.2.1.1.3TablecommonMulticastAddressTablenot-accessiblemandatoryMulticast addresses Table, the value of this object should be stored in nonvolatile memory.
1.3.6.1.4.1.17409.1.3.2.1.1.3.1RowcommonMulticastAddressEntrynot-accessiblemandatoryMulticast addresses head table.
1.3.6.1.4.1.17409.1.3.2.1.1.3.1.1ColumncommonMulticastAddressIndexread-onlymandatoryMulticast addresses head table.
1.3.6.1.4.1.17409.1.3.2.1.1.3.1.2ColumncommonMulticastAddressNumberread-writemandatoryMulticast address, I / G-1 effective.
1.3.6.1.4.1.17409.1.3.2.1.2NodecommonBackoffParams
1.3.6.1.4.1.17409.1.3.2.1.2.1ScalarcommonBackoffPeriodread-writemandatoryBackoff algorithm benchmark time (ms), initialize the default value of 6 ms.The value of this object should be stored in nonvolatile memory.
1.3.6.1.4.1.17409.1.3.2.1.2.2ScalarcommonACKTimeoutWindowread-writemandatoryNE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms.The value of this object should be stored in nonvolatile memory.
1.3.6.1.4.1.17409.1.3.2.1.2.3ScalarcommonMaximumMACLayerRetriesread-writemandatoryNE data packets sent the greatest number of re-examination. Initialize the default value is 16.The value of this object should be stored in nonvolatile memory.
1.3.6.1.4.1.17409.1.3.2.1.2.4ScalarcommonMaxPayloadSizeread-onlymandatoryFrom top to bottom line channel packet supported by the largest payload (payload) the length of
1.3.6.1.4.1.17409.1.3.2.1.2.5ScalarcommonBackoffMinimumExponentread-writemandatoryThe standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6.This value may not exceed comm…
1.3.6.1.4.1.17409.1.3.2.1.2.6ScalarcommonBackoffMaximumExponentread-writemandatoryThe body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15.This value shall be not l…
1.3.6.1.4.1.17409.1.3.2.1.3NodecommonMacStats
1.3.6.1.4.1.17409.1.3.2.1.3.1ScalarcommonForwardPathLOSEventsread-writeoptionalLOS downlink channel in the number of reset to 0.
1.3.6.1.4.1.17409.1.3.2.1.3.2ScalarcommonForwardPathFramingErrorsread-writeoptionalDownlink Channel frames wrong number reset to 0.
1.3.6.1.4.1.17409.1.3.2.1.3.3ScalarcommonForwardPathCRCErrorsread-writeoptionalCRC errors down the number of reset to 0.
1.3.6.1.4.1.17409.1.3.2.1.3.4ScalarcommonInvalidMacCmdsread-writeoptionalInvalid MAC layer order wrong number reset to 0.
1.3.6.1.4.1.17409.1.3.2.1.3.5ScalarcommonBackwardPathCollisionTimesread-writeoptionalUplink Packet collision frequency, reset to 0.
1.3.6.1.4.1.17409.1.3.2.2NodecommonRfGroup
1.3.6.1.4.1.17409.1.3.2.2.1ScalarcommonReturnPathFrequencyread-onlymandatoryChannel uplink frequency units Hz.The value of this object should be stored in non-volatile memory
1.3.6.1.4.1.17409.1.3.2.2.2ScalarcommonForwardPathFrequencyread-onlymandatoryDownlink frequency channel, flat Hz.The value of this object should be stored in nonvolatile memory.
1.3.6.1.4.1.17409.1.3.2.2.3ScalarcommonProvisionedReturnPowerLevelread-writemandatoryUpstream channel power levels and units for dBuV.When the internal use of this value will be rounded to the nearest support value. Reading return to this subje…
1.3.6.1.4.1.17409.1.3.2.2.4ScalarcommonForwardPathReceiveLevelread-onlyoptionalDownlink Channel receive power levels, units dBuV.
1.3.6.1.4.1.17409.1.3.2.2.5ScalarcommonMaxReturnPowerread-writemandatoryThe largest upstream channel power levels and units for dBuV.The value of this object should be stored in nonvolatile memory.
1.3.6.1.4.1.17409.1.3.3NodecommonAdminUseEthernet
1.3.6.1.4.1.17409.1.3.3.1NodecommonAgentGroup
1.3.6.1.4.1.17409.1.3.3.1.1ScalarcommonAgentBootWayread-writemandatory
1.3.6.1.4.1.17409.1.3.3.1.2ScalarcommonAgentResetread-writemandatoryActing Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had…
1.3.6.1.4.1.17409.1.3.3.1.3ScalarcommonAgentMaxTrapsread-writemandatoryActing detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values
1.3.6.1.4.1.17409.1.3.3.1.4ScalarcommonAgentTrapMinIntervalread-writemandatoryActing TRAP send the minimum spacing units
1.3.6.1.4.1.17409.1.3.3.1.5ScalarcommonAgentTrapMaxIntervalread-writemandatoryActing TRAP send the largest spacing units for
1.3.6.1.4.1.17409.1.3.3.1.6ScalarcommonTrapAckread-writeoptionalThe variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the va…
1.3.6.1.4.1.17409.1.3.3.1.7TablecommonAgentTrapTablenot-accessiblemandatoryActing Information Table TRAP
1.3.6.1.4.1.17409.1.3.3.1.7.1RowcommonAgentTrapEntrynot-accessiblemandatoryActing Head TRAP Information Table
1.3.6.1.4.1.17409.1.3.3.1.7.1.1ColumncommonAgentTrapIndexread-onlymandatoryTRAP Table Index
1.3.6.1.4.1.17409.1.3.3.1.7.1.2ColumncommonAgentTrapIPread-writemandatoryWhen the purpose of the TRAP host's IP address
1.3.6.1.4.1.17409.1.3.3.1.7.1.3ColumncommonAgentTrapCommunityread-writemandatorySend the Community string TRAP
1.3.6.1.4.1.17409.1.3.3.1.7.1.4ColumncommonAgentTrapStatusread-writemandatoryIt said that the opening of TRAP
1.3.6.1.4.1.17409.1.3.3.2NodecommonDeviceGroup
1.3.6.1.4.1.17409.1.3.3.2.1ScalarcommonDeviceNumread-writemandatoryThe agent said that the current management is the number of devices
1.3.6.1.4.1.17409.1.3.3.2.2TablecommonDeviceInfoTablenot-accessiblemandatoryActing is currently public information management equipment list.
1.3.6.1.4.1.17409.1.3.3.2.2.1RowcommonDeviceInfoEntrynot-accessiblemandatoryActing is currently public information management equipment list Table Head.
1.3.6.1.4.1.17409.1.3.3.2.2.1.1ColumncommonDeviceSlotread-onlymandatoryActing is currently under the management of the equipment list of public information table index.
1.3.6.1.4.1.17409.1.3.3.2.2.1.2ColumncommonDevicesIDread-onlymandatoryDesignated equipment manufacturers logo
1.3.6.1.4.1.17409.1.3.3.2.2.1.3ColumncommonDeviceVendorread-onlymandatoryEquipment manufacturers
1.3.6.1.4.1.17409.1.3.3.2.2.1.4ColumncommonDeviceModelNumberread-onlymandatoryEquipment models.
1.3.6.1.4.1.17409.1.3.3.2.2.1.5ColumncommonDeviceSerialNumberread-onlymandatoryThe string of equipment.
1.3.6.1.4.1.17409.1.3.3.2.2.1.6ColumncommonDeviceVendorInforead-onlyoptionalEquipment suppliers of other special designated information
1.3.6.1.4.1.17409.1.3.3.2.2.1.7ColumncommonDeviceStatusread-onlymandatoryBit 0: RSVD0 Bit 1: RSVD1 Bit 2: RSVD2 Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD5 Bit 6: RSVD6 Bit 7: RSVD7
1.3.6.1.4.1.17409.1.3.3.2.2.1.8ColumncommonDeviceResetread-writemandatoryWrite'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', the equipment had no effect.
1.3.6.1.4.1.17409.1.3.3.2.2.1.9ColumncommonDeviceAlarmDetectionControlread-writemandatoryThis object used to control equipment alarm detection.
1.3.6.1.4.1.17409.1.3.3.2.2.1.10ColumncommonDeviceMACAddressread-onlymandatoryEquipment MAC address
1.3.6.1.4.1.17409.1.3.3.2.2.1.11ColumncommonDeviceTamperStatusread-onlyoptionalReport of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the…
1.3.6.1.4.1.17409.1.3.3.2.2.1.12ColumncommonDeviceInternalTemperatureread-onlyoptionalEquipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table
1.3.6.1.4.1.17409.1.3.3.2.2.1.13ColumncommonDeviceResetCauseread-onlymandatoryEquipment that the reasons for the recent reduction
1.3.6.1.4.1.17409.1.3.3.2.2.1.14ColumncommonDeviceCraftStatusread-onlymandatoryThis object interface that local equipment (such as RS232 or RS485 interface) state.
1.3.6.1.4.1.17409.1.3.3.2.2.1.15ColumncommonDevicesOIDread-onlymandatoryGoals identifier string, point to a concrete realization of the equipment
1.3.6.1.4.1.17409.1.3.3.2.2.1.16ColumncommonDeviceAcctread-onlyoptionalEquipment that the accumulated work time, units of s
1.3.6.1.4.1.17409.1.3.3.2.2.1.17ColumncommonDeviceNameread-onlymandatoryEquipment name
1.3.6.1.4.1.17409.1.3.3.2.2.1.18ColumncommonDeviceMFDread-onlymandatoryEquipment manufacturing date.
1.3.6.1.4.1.17409.1.3.3.2.2.1.19ColumncommonDeviceFWread-onlymandatoryEquipment firmware information
1.3.6.1.4.1.17409.1.15NodeoswIdent
1.3.6.1.4.1.17409.1.15.1ScalaroswVendorOIDread-onlyoptionalThis object provides manufacturers of optical switch MIB expansion. Without the expansion, this should be targeting at the optical switch nodes oswIdent
1.3.6.1.4.1.17409.1.15.2ScalaroswModeread-writemandatoryThe work modes of the optical switch:'1' indicates the switch choose route B��'2' indicates the switch choose route A��'3' indicates the switch choose …
1.3.6.1.4.1.17409.1.15.3ScalaroswSwitchread-writemandatoryOptical switch breaking point
1.3.6.1.4.1.17409.1.15.4TableoswChannelTablenot-accessiblemandatoryOptical Switch Information Table
1.3.6.1.4.1.17409.1.15.4.1RowoswChannelEntrynot-accessiblemandatoryOptical Switch Information Table Head
1.3.6.1.4.1.17409.1.15.4.1.1ColumnoswIndexread-onlymandatory
1.3.6.1.4.1.17409.1.15.4.1.2ColumnoswInputAread-onlymandatoryThe input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB.
1.3.6.1.4.1.17409.1.15.4.1.3ColumnoswInputBread-onlymandatoryThe input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB.
1.3.6.1.4.1.17409.1.15.4.1.4ColumnoswOutput1read-onlymandatoryThe input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB.
1.3.6.1.4.1.17409.1.15.4.1.5ColumnoswOutput2read-onlymandatoryThe input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB.
1.3.6.1.4.1.17409.1.15.5ScalaroswNumberDCPowerSupplyread-onlymandatoryThe number of internal DC power supply,'0 'indicates the transponder nonsupport this function.
1.3.6.1.4.1.17409.1.15.6ScalaroswDCPowerSupplyModeread-onlyoptionalPower supply work modes: Load and load-sharing, standby switch, or independency power supply. If the equipment has only one DC power supply, this should not be…
1.3.6.1.4.1.17409.1.15.7TableoswDCPowerTablenot-accessiblemandatoryDC Power Information Table
1.3.6.1.4.1.17409.1.15.7.1RowoswDCPowerEntrynot-accessiblemandatoryDC Power Information Table Head
1.3.6.1.4.1.17409.1.15.7.1.1ColumnoswDCPowerIndexread-onlymandatoryDC Power Index, table oswDCPowerTable index
1.3.6.1.4.1.17409.1.15.7.1.2ColumnoswDCPowerVoltageread-onlymandatoryPower supply voltage, unit in 0.1 V, this object require entry register in the attribute MIB.
1.3.6.1.4.1.17409.1.15.7.1.3ColumnoswDCPowerCurrentread-onlymandatoryPower supply current, unit in 0.1 A, this object require entry register in the attribute MIB.