OLD-CISCO-ENV-MIB
37 objects
No module-level DESCRIPTION found.
Imported Objects
| CISCO-SMI | local |
| RFC-1212 | OBJECT-TYPE |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9.2.1 | Nodelenv | |||
| 1.3.6.1.4.1.9.2.1.77 | ScalarenvPresent | read-only | mandatory | Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support |
| 1.3.6.1.4.1.9.2.1.78 | ScalarenvTestPt1Descr | read-only | mandatory | Description of the test point 1. Typically ambient air or the temperature of air entering the router |
| 1.3.6.1.4.1.9.2.1.79 | ScalarenvTestPt1Measure | read-only | mandatory | Current value of test point 1. Typically a temperature in centigrade. |
| 1.3.6.1.4.1.9.2.1.80 | ScalarenvTestPt2Descr | read-only | mandatory | Description of the test point 2. Typically airflow or the temperature of air leaving the router |
| 1.3.6.1.4.1.9.2.1.81 | ScalarenvTestPt2Measure | read-only | mandatory | Current value of test point 2. Typically a temperature in centigrade. |
| 1.3.6.1.4.1.9.2.1.82 | ScalarenvTestPt3Descr | read-only | mandatory | Description of the test point 3. Typically +5 volt |
| 1.3.6.1.4.1.9.2.1.83 | ScalarenvTestPt3Measure | read-only | mandatory | Current value of test point 3. Typically the value in millivolts of the +5v supply |
| 1.3.6.1.4.1.9.2.1.84 | ScalarenvTestPt4Descr | read-only | mandatory | Description of the test point 4. Typically +12 volt |
| 1.3.6.1.4.1.9.2.1.85 | ScalarenvTestPt4Measure | read-only | mandatory | Current value of test point 4. Typically the value in millivolts of the +12v supply |
| 1.3.6.1.4.1.9.2.1.86 | ScalarenvTestPt5Descr | read-only | mandatory | Description of the test point 5. Typically -12 volt |
| 1.3.6.1.4.1.9.2.1.87 | ScalarenvTestPt5Measure | read-only | mandatory | Current value of test point 5. Typically the value in millivolts of the -12v supply |
| 1.3.6.1.4.1.9.2.1.88 | ScalarenvTestPt6Descr | read-only | mandatory | Description of the test point 6. Typically -5 volt |
| 1.3.6.1.4.1.9.2.1.89 | ScalarenvTestPt6Measure | read-only | mandatory | Current value of test point 6. Typically the value in millivolts of the -5v supply |
| 1.3.6.1.4.1.9.2.1.90 | ScalarenvTestPt1MarginVal | read-only | mandatory | Value at which the router will shutdown. Typically the ambient air temperature that will shut the router down. (e.g. 43) |
| 1.3.6.1.4.1.9.2.1.91 | ScalarenvTestPt2MarginVal | read-only | mandatory | Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58) |
| 1.3.6.1.4.1.9.2.1.92 | ScalarenvTestPt3MarginPercent | read-only | mandatory | +/- Percentage that will shut the router down, (e.g. 10%) typically +5 volt |
| 1.3.6.1.4.1.9.2.1.93 | ScalarenvTestPt4MarginPercent | read-only | mandatory | +/- Percentage that will shut the router down, (e.g. 15%) typically +12 volt |
| 1.3.6.1.4.1.9.2.1.94 | ScalarenvTestPt5MarginPercent | read-only | mandatory | +/- Percentage that will shut the router down, (e.g. 15%) typically -12 volt |
| 1.3.6.1.4.1.9.2.1.95 | ScalarenvTestPt6MarginPercent | read-only | mandatory | +/- Percentage that will shut the router down, (e.g. 10%) typically -5 volt |
| 1.3.6.1.4.1.9.2.1.96 | ScalarenvTestPt1last | read-only | mandatory | Value of TestPt1 when last shutdown occurred. |
| 1.3.6.1.4.1.9.2.1.97 | ScalarenvTestPt2last | read-only | mandatory | Value of TestPt2 when last shutdown occurred. |
| 1.3.6.1.4.1.9.2.1.98 | ScalarenvTestPt3last | read-only | mandatory | Value of TestPt3 when last shutdown occurred. |
| 1.3.6.1.4.1.9.2.1.99 | ScalarenvTestPt4last | read-only | mandatory | Value of TestPt4 when last shutdown occurred. |
| 1.3.6.1.4.1.9.2.1.100 | ScalarenvTestPt5last | read-only | mandatory | Value of TestPt5 when last shutdown occurred. |
| 1.3.6.1.4.1.9.2.1.101 | ScalarenvTestPt6last | read-only | mandatory | Value of TestPt6 when last shutdown occurred. |
| 1.3.6.1.4.1.9.2.1.102 | ScalarenvTestPt1warn | read-only | mandatory | Is this test point at a warning level? |
| 1.3.6.1.4.1.9.2.1.103 | ScalarenvTestPt2warn | read-only | mandatory | Is this test point at a warning level? |
| 1.3.6.1.4.1.9.2.1.104 | ScalarenvTestPt3warn | read-only | mandatory | Is this test point at a warning level? |
| 1.3.6.1.4.1.9.2.1.105 | ScalarenvTestPt4warn | read-only | mandatory | Is this test point at a warning level? |
| 1.3.6.1.4.1.9.2.1.106 | ScalarenvTestPt5warn | read-only | mandatory | Is this test point at a warning level? |
| 1.3.6.1.4.1.9.2.1.107 | ScalarenvTestPt6warn | read-only | mandatory | Is this test point at a warning level? |
| 1.3.6.1.4.1.9.2.1.108 | ScalarenvFirmVersion | read-only | mandatory | Description of Environmental Card firmware |
| 1.3.6.1.4.1.9.2.1.109 | ScalarenvTechnicianID | read-only | mandatory | Technician ID |
| 1.3.6.1.4.1.9.2.1.110 | ScalarenvType | read-only | mandatory | The type of environmental card |
| 1.3.6.1.4.1.9.2.1.111 | ScalarenvBurnDate | read-only | mandatory | The calibration / burn in date |
| 1.3.6.1.4.1.9.2.1.112 | ScalarenvSerialNumber | read-only | mandatory | Serial Number of environmental monitor card |