ONS15501-MIB
108 objects
The MIB definitions for ONS-15501 Optical Amplifier.
Imported Objects
| ENTITY-MIB | PhysicalIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | enterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime DisplayString TEXTUAL-CONVENTION TimeStamp |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1869 | Nodesynchronous | |||
| 1.3.6.1.4.1.1869.11 | NodesynEmbLx | |||
| 1.3.6.1.4.1.1869.11.11 | Identityons15501MIB | The MIB definitions for ONS-15501 Optical Amplifier. | ||
| 1.3.6.1.4.1.1869.11.11.1 | Nodeons15501Sys | |||
| 1.3.6.1.4.1.1869.11.11.1.1 | Scalarons15501SysDevFlash1Image | read-only | current | Gives the name of the software programmed on flash bank one. |
| 1.3.6.1.4.1.1869.11.11.1.2 | Scalarons15501SysDevFlash2Image | read-only | current | Gives the name of the software programmed on flash bank two. |
| 1.3.6.1.4.1.1869.11.11.1.3 | Scalarons15501SysDevFlash3Image | read-only | current | Gives the name of the software programmed on flash bank three. |
| 1.3.6.1.4.1.1869.11.11.1.4 | Scalarons15501SysSwDownload | read-write | current | Used to control the image download to the flash banks. NOTE: Read on this attribute returns the last t/ftp command, without login/password. For s/w release 4.0… |
| 1.3.6.1.4.1.1869.11.11.1.5 | Scalarons15501SysDevActiveImage | read-only | current | Show currently active image's bank number. This may be different from ons15501SysConfiguredActiveImage, if a. The image on ons15501SysConfiguredActiveImage did… |
| 1.3.6.1.4.1.1869.11.11.1.6 | Scalarons15501SysDeviceManagerList | read-only | current | A ',' separated list of managers that will receive the Traps. If a specific host should receive the traps sent from this unit, it should be added to the list u… |
| 1.3.6.1.4.1.1869.11.11.1.7 | Scalarons15501SysSwDownloadStatus | read-only | current | Denotes the FTP/TFTP status. Please refer to the description of Ons15501ImageDnLoadStatus for a list of supported values |
| 1.3.6.1.4.1.1869.11.11.1.8 | Scalarons15501SysConfiguredImage | read-write | current | Set/Show configured value for flash-bank number to be used on reboot. A set on this attribute will result in a reboot of the system. To restart the system, wri… |
| 1.3.6.1.4.1.1869.11.11.1.9 | Scalarons15501CLEICode | read-only | current | This attribute represents the CLEI (Common Language Equipment Identifier) code for the ONS15501. |
| 1.3.6.1.4.1.1869.11.11.1.10 | Scalarons15501PrimaryNTP | read-write | current | The IP address for the primary NTP server. |
| 1.3.6.1.4.1.1869.11.11.1.11 | Scalarons15501SecondaryNTP | read-write | current | The IP address for the secondary NTP server. |
| 1.3.6.1.4.1.1869.11.11.1.12 | Scalarons15501NTPAdminStatus | read-write | current | The configured administrative status for NTP. |
| 1.3.6.1.4.1.1869.11.11.1.13 | Scalarons15501NTPOperationalStatus | read-only | current | The operational status for NTP. |
| 1.3.6.1.4.1.1869.11.11.1.14 | Scalarons15501ActiveSoftwareVer | read-only | current | This attribute provides the active software version. This will be same as the entPhysicalSoftwareRev for the entry corresponding to the chassis. |
| 1.3.6.1.4.1.1869.11.11.1.15 | Scalarons15501LastConfigChangeTime | read-only | current | The value of sysUpTime when last configuration change was done. NMS may use this information to synchronize if some configuration has changed on the unit. |
| 1.3.6.1.4.1.1869.11.11.1.16 | Scalarons15501InRemoteInfoUpdateTime | read-only | current | This attribute gives the time-stamp when one or more of ons15501InRemoteChassisName, ons15501InRemotePortName, or ons15501InRemoteAgentIpAddr was changed. NMS … |
| 1.3.6.1.4.1.1869.11.11.1.17 | Scalarons15501InRemoteChassisName | read-write | current | Manager initialized string value to identify the chassis associated with remote connection for optical input. ons15501InRemoteChassisName would be a ZERO lengt… |
| 1.3.6.1.4.1.1869.11.11.1.18 | Scalarons15501InRemotePortName | read-write | current | Manager initialized string value to identify the the port (on remote chassis) associated with remote connection for optical input. ons15501InRemotePortName wou… |
| 1.3.6.1.4.1.1869.11.11.1.19 | Scalarons15501InRemoteAgentIpAddr | read-write | current | Manager initialized string value to identify the network address to be used to reach the SNMP agent entity containing information about the port and chassis pr… |
| 1.3.6.1.4.1.1869.11.11.1.20 | Scalarons15501OutRemoteInfoUpdateTime | read-only | current | This attribute gives the time-stamp when one or more of ons15501OutRemoteChassisName, ons15501OutRemotePortName, or ons15501OutRemoteAgentIpAddr was changed. N… |
| 1.3.6.1.4.1.1869.11.11.1.21 | Scalarons15501OutRemoteChassisName | read-write | current | Manager initialized string value to identify the chassis associated with remote connection for optical output. ons15501OutRemoteChassisName would be a ZERO len… |
| 1.3.6.1.4.1.1869.11.11.1.22 | Scalarons15501OutRemotePortName | read-write | current | Manager initialized string value to identify the the port (on remote chassis) associated with remote connection for optical output. ons15501OutRemotePortName w… |
| 1.3.6.1.4.1.1869.11.11.1.23 | Scalarons15501OutRemoteAgentIpAddr | read-write | current | Manager initialized string value to identify the network address to be used to reach the SNMP agent entity containing information about the port and chassis us… |
| 1.3.6.1.4.1.1869.11.11.1.24 | Scalarons15501SysAlarmStatus | read-only | current | Provides the highest severity alarm currently active. |
| 1.3.6.1.4.1.1869.11.11.1.25 | Scalarons15501SysDateAndTime | read-write | current | The date and time of the System. The write will not succeed if the administrative state for NTP (ons15501NTPAdminStatus) is 'enabled'. Setting this attribute w… |
| 1.3.6.1.4.1.1869.11.11.2 | Nodeons15501Attr | |||
| 1.3.6.1.4.1.1869.11.11.2.1 | Scalarons15501InputOpticalPower | read-only | current | The optical power being fed into the Amplifier. |
| 1.3.6.1.4.1.1869.11.11.2.2 | Scalarons15501InputOpticalPowerMean | read-write | current | Mean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputOpticalPowerTrigger) an alarm … |
| 1.3.6.1.4.1.1869.11.11.2.3 | Scalarons15501InputOpticalPowerTrigger | read-write | current | Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the input optica… |
| 1.3.6.1.4.1.1869.11.11.2.4 | Scalarons15501OutputOpticalPower | read-only | current | The measured value for raw optical power being generated at the output of the Amplifier. |
| 1.3.6.1.4.1.1869.11.11.2.5 | Scalarons15501OutputSignalPower | read-only | current | The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501… |
| 1.3.6.1.4.1.1869.11.11.2.6 | Scalarons15501OutputSignalPowerMean | read-write | current | Mean value for output optical power. If the output signal power falls below (or goes above) the mean value by more than trigger (see ons15501OutputSignalPowerT… |
| 1.3.6.1.4.1.1869.11.11.2.7 | Scalarons15501OutputSignalPowerTrigger | read-write | current | Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the output signa… |
| 1.3.6.1.4.1.1869.11.11.2.8 | Scalarons15501ConfigOpticalGain | read-write | current | The configured value for power gain. |
| 1.3.6.1.4.1.1869.11.11.2.9 | Scalarons15501OpticalPowerGain | read-only | current | The measured value for power gain. This value does not include the amplification noise that is significant for low input signals. |
| 1.3.6.1.4.1.1869.11.11.2.10 | Scalarons15501GainTrigger | read-write | current | The gain deviation allowed from the configured gain before an alarm is asserted. The alarm is not cleared, until measured gain(ons15501OpticalPowerGain) is bac… |
| 1.3.6.1.4.1.1869.11.11.2.11 | Scalarons15501PowerSupply1Level | read-only | current | The voltage fed through power supply 1. The value of the attribute is 10 times the the value in volts. |
| 1.3.6.1.4.1.1869.11.11.2.12 | Scalarons15501PowerSupply2Level | read-only | current | The voltage fed through power supply 2. The value of the attribute is 10 times the the value in volts. |
| 1.3.6.1.4.1.1869.11.11.2.13 | Scalarons15501LaserStatus | read-only | current | Gives the status of the laser pumps. |
| 1.3.6.1.4.1.1869.11.11.2.14 | Scalarons15501DevAmbTemp | read-only | current | The ambient temperature for the device. |
| 1.3.6.1.4.1.1869.11.11.2.15 | Scalarons15501DevAmbTempMean | read-write | current | Mean value for temperature. If the temperature falls below (or goes above) the mean value by more than trigger level (see ons15501DevAmbTempTrigger) an alarm i… |
| 1.3.6.1.4.1.1869.11.11.2.16 | Scalarons15501DevAmbTempTrigger | read-write | current | Please refer to ons15501DevAmbTempMean above. Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is gener… |
| 1.3.6.1.4.1.1869.11.11.2.17 | Scalarons15501PowerSupply1Status | read-only | current | Gives the status of power supply one. |
| 1.3.6.1.4.1.1869.11.11.2.18 | Scalarons15501PowerSupply2Status | read-only | current | Gives the status of power supply two. |
| 1.3.6.1.4.1.1869.11.11.3 | Nodeons15501Alarms | |||
| 1.3.6.1.4.1.1869.11.11.3.1 | Scalarons15501LastTrapIndex | read-only | current | The value of ons15501TrapLogEntryIndex, used while logging the most recent trap. Goes back to 1, after reaching the max value. The trap log table is a circular… |
| 1.3.6.1.4.1.1869.11.11.3.2 | Tableons15501TrapLogTable | not-accessible | current | Table for last N traps (N = 100 in most cases). Please refer to ons15501LastTrapIndex for details on how this table is organized. |
| 1.3.6.1.4.1.1869.11.11.3.2.1 | Rowons15501TrapLogEntry | not-accessible | current | Entry for a trap |
| 1.3.6.1.4.1.1869.11.11.3.2.1.1 | Columnons15501TrapLogEntryIndex | not-accessible | current | index field for this entry. Actual range at run time is ons15501TrapCounter to ons15501TrapCounter - N + 1 or 1 (whichever is higher) |
| 1.3.6.1.4.1.1869.11.11.3.2.1.2 | Columnons15501TrapLogEntryTrapType | read-only | current | The type of trap. See the definition of Ons15501TrapTypeEnumeration for possible values. |
| 1.3.6.1.4.1.1869.11.11.3.2.1.3 | Columnons15501TrapLogEntryDirection | read-only | current | Whether the trap is being asserted or cleared. Please note that some traps don't have a direction. (e.g. configuration changed). |
| 1.3.6.1.4.1.1869.11.11.3.2.1.4 | Columnons15501TrapLogEntryTimeStamp | read-only | current | The value of sysUpTime when the entry was placed in the log. |
| 1.3.6.1.4.1.1869.11.11.3.2.1.5 | Columnons15501TrapLogEntryDateAndTime | read-only | current | The local date and time at which the entry was placed in the log. |
| 1.3.6.1.4.1.1869.11.11.3.2.1.6 | Columnons15501TrapLogEntryPhyIndex | read-only | current | Provides entPhysicalIndex value for the physical entity corresponding to the trap entry. |
| 1.3.6.1.4.1.1869.11.11.3.2.1.7 | Columnons15501TrapLogEntrySeverity | read-only | current | Provides the severity level corresponding to this trap entry. |
| 1.3.6.1.4.1.1869.11.11.3.3 | Tableons15501ActiveAlarmTable | not-accessible | current | Table for currently active alarm conditions. This table is effectively the list of traps that have been asserted but not cleared. |
| 1.3.6.1.4.1.1869.11.11.3.3.1 | Rowons15501ActiveAlarmEntry | not-accessible | current | Entry for an active alarm condition. For each alarm condition present on the equipment, there would be an entry in the table. |
| 1.3.6.1.4.1.1869.11.11.3.3.1.1 | Columnons15501ActAlarmType | not-accessible | current | Index field for ons15501ActiveAlarmTable. Presence of an entry implies that the specific alarm type is active on the unit. |
| 1.3.6.1.4.1.1869.11.11.3.3.1.2 | Columnons15501ActAlarmTimeStamp | read-only | current | The time since when the alarm is active. |
| 1.3.6.1.4.1.1869.11.11.3.3.1.3 | Columnons15501ActAlarmDateAndTime | read-only | current | The local date and time since when the alarm is active |
| 1.3.6.1.4.1.1869.11.11.3.3.1.4 | Columnons15501ActAlarmPhyIndex | read-only | current | Provides entPhysicalIndex value for the physical entity corresponding to the alarm entry. |
| 1.3.6.1.4.1.1869.11.11.3.3.1.5 | Columnons15501ActAlarmSeverity | read-only | current | Provides the severity level corresponding to this alarm entry. |
| 1.3.6.1.4.1.1869.11.11.3.4 | Tableons15501TrapDescriptionTable | not-accessible | current | Table for mapping the Ons15501TrapTypeEnumeration values to their textual information. |
| 1.3.6.1.4.1.1869.11.11.3.4.1 | Rowons15501TrapDescriptionEntry | not-accessible | current | Entry for textual information about traps. |
| 1.3.6.1.4.1.1869.11.11.3.4.1.1 | Columnons15501TrapTypeValue | not-accessible | current | Index field for this entry. |
| 1.3.6.1.4.1.1869.11.11.3.4.1.2 | Columnons15501TrapDescription | read-only | current | The textual information corresponding to the ons15501TrapTypeValue. |
| 1.3.6.1.4.1.1869.11.11.3.4.1.3 | Columnons15501TrapSeverity | read-only | current | Provides the default severity level corresponding to the ons15501TrapTypeValue. |
| 1.3.6.1.4.1.1869.11.11.4 | Nodeons15501Notification | |||
| 1.3.6.1.4.1.1869.11.11.4.0 | Nodeons15501NotificationPrefix | |||
| 1.3.6.1.4.1.1869.11.11.4.0.1 | Notificationons15501GenericNotificationTrap | current | This notification is generated whenever a bitmap change is observed on any of the monitored equipment, or when a change has to be notified. | |
| 1.3.6.1.4.1.1869.11.11.5 | Nodeons15501OIDs | |||
| 1.3.6.1.4.1.1869.11.11.5.1 | Nodeons15501OIDSystem | |||
| 1.3.6.1.4.1.1869.11.11.5.2 | Nodeons15501OIDEntity | |||
| 1.3.6.1.4.1.1869.11.11.5.2.1 | Nodeons15501OIDChasiss | |||
| 1.3.6.1.4.1.1869.11.11.5.2.2 | Nodeons15501OIDInPort | |||
| 1.3.6.1.4.1.1869.11.11.5.2.3 | Nodeons15501OIDOutPort | |||
| 1.3.6.1.4.1.1869.11.11.5.2.4 | Nodeons15501OIDPowerSupply | |||
| 1.3.6.1.4.1.1869.11.11.5.2.5 | Nodeons15501OIDChassisAC | |||
| 1.3.6.1.4.1.1869.11.11.5.2.6 | Nodeons15501OIDPowerSupplyAC | |||
| 1.3.6.1.4.1.1869.11.11.5.3 | Nodeons15501OIDSystemAC | |||
| 1.3.6.1.4.1.1869.11.11.6 | Nodeons15501MIBConformance | |||
| 1.3.6.1.4.1.1869.11.11.6.1 | Nodeons15501MIBCompliances | |||
| 1.3.6.1.4.1.1869.11.11.6.1.1 | Complianceons15501FinalCompliance | deprecated | The compliance statement for final release ONS15501. | |
| 1.3.6.1.4.1.1869.11.11.6.1.2 | Complianceons15501Rel4Compliance | current | The compliance statement for 4.0 release ONS15501. | |
| 1.3.6.1.4.1.1869.11.11.6.2 | Nodeons15501MIBGroups | |||
| 1.3.6.1.4.1.1869.11.11.6.2.1 | Groupons15501SysInfoGroup | deprecated | The basic group defines objects which are common to all Embedded Linux product series of Synchronous equipment. | |
| 1.3.6.1.4.1.1869.11.11.6.2.2 | Groupons15501TrapLogGroup | current | The trap attribute group provides the trap logs. These attributes are also used in trap notifications. | |
| 1.3.6.1.4.1.1869.11.11.6.2.3 | Groupons15501ActiveAlarmGroup | current | The alarm attribute group provides the list of active alarms | |
| 1.3.6.1.4.1.1869.11.11.6.2.4 | Groupons15501TrapDescriptionGroup | current | The trap description attribute group provides the mapping from trap type to textual information about the trap. | |
| 1.3.6.1.4.1.1869.11.11.6.2.5 | Groupons15501FinalAttrGroup | deprecated | The ons15501 group of attributes models the parameters in the EDFA. | |
| 1.3.6.1.4.1.1869.11.11.6.2.6 | Groupons15501FinalNotificationsGroup | current | The notification that carries all the exception information. | |
| 1.3.6.1.4.1.1869.11.11.6.2.7 | Groupons15501CoreAttrGroup | current | The ons15501 group of attributes models the parameters in the EDFA. The power supply related attributes are not part of this group. | |
| 1.3.6.1.4.1.1869.11.11.6.2.8 | Groupons15501PowerSupplyStatusGroup | current | The ons15501 group of attributes models the status of power supplies. The support for status was introduced in version 4.0. | |
| 1.3.6.1.4.1.1869.11.11.6.2.9 | Groupons15501PowerSupplyLevelGroup | current | The ons15501 group of attributes provides the voltage level of power supplies. It is available only for DC series of ONS15501. | |
| 1.3.6.1.4.1.1869.11.11.6.2.10 | Groupons15501SysInfoGroup2 | current | The basic group defines objects which are common to all Embedded Linux product series of Synchronous equipment. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Ons15501AdminStatus | INTEGER { disabled(1), enabled(2) } | current | The Administrative state for a configured object. |
| Ons15501AlarmStatus | INTEGER { critical(1), major(2), minor(3), info(4), noAlarm(5) } | current | Represents a alarm level |
| Ons15501ImageDnLoadStatus | INTEGER { notInitiated(1), inProgress(2), failedUnknownErr(3), failedFileNotFound(4), failedAccessDenied(5), failedTimedOut(6), completedSuccessfully(7), failedInDownload(8), failedTimeoutInDownload(9), failedToConnectToServer(10), failedWhileWritingToFlash(11), failedIllegalOperation(12), failedFileExists(13), failedUnknownTransferId(14), failedUnknownUser(15) } | current | The operational states for software image download. This enumerates all possible failure conditions. |
| Ons15501NTPStatus | INTEGER { disabled(1), bothServersBad(2), usingPrimary(3), usingSecondary(4), unknown(5) } | current | The operational state for NTP client. It may be 'unknown' if the NTP client has just started. |
| Ons15501TenthCentigrade | Integer32(-500..1000) | current | This data type represents temperature values that are normally expressed in Centigrade. Units are in tenths of a Centigrade; for example, -5.1 Centigrade will be represented as -51. |
| Ons15501TenthdB | Integer32(-1000..500) | current | This data type represents power levels (or power gain) that are normally expressed in dBm (dB). Units are in tenths of a dBm (db); for example, -5.1 dB will be represented as -51 |
| Ons15501TenthVolt | Integer32(-1000..0) | current | This data type represents voltage levels that are normally expressed in volts. Units are in tenths of a volt; for example, -48.1 volts will be represented as -481. |
| Ons15501TrapDirectionEnumeration | INTEGER { dontCare(1), asserted(2), cleared(3) } | current | Represents a alarm level |
| Ons15501TrapTypeEnumeration | INTEGER { unacceptableAmbientTemperature(1), unacceptableElectricalPower(2), inputSignalPowerTooLow(3), unacceptableOutputSignalPower(4), embeddedControllerCommFailure(5), softwareUpgradeInitiated(6), softwareUpgradeFailed(7), softwareUpgradeCompleted(8), softwareRebootInitiated(9), softwareRolledBack(10), configurationChanged(11), unacceptableGain(12), laserPumpBad(13), eEPROMBad(14), unknown(32767) } | current | This provides the details on type of alarm none - No exception unacceptableAmbientTemperature, - the temperature measured by thermal sensor shows value outside the operational limits. unacceptableElectricalPower, - the … |