OPT-IF-MIB
484 objects
The MIB module to describe pre-OTN and OTN interfaces. Copyright (C) The Internet Society (2003). This version of this MIB module is part of RFC 3591; see the RFC itself for full legal notices.
Imported Objects
| IF-MIB | ifIndex |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Gauge32 Integer32 MODULE-IDENTITY OBJECT-TYPE transmission Unsigned32 |
| SNMPv2-TC | RowPointer RowStatus TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.10.133 | IdentityoptIfMibModule | The MIB module to describe pre-OTN and OTN interfaces. Copyright (C) The Internet Society (2003). This version of this MIB module is part of RFC 3591; see the … | ||
| 1.3.6.1.2.1.10.133.1 | NodeoptIfObjects | |||
| 1.3.6.1.2.1.10.133.1.1 | NodeoptIfOTMn | |||
| 1.3.6.1.2.1.10.133.1.1.1 | TableoptIfOTMnTable | not-accessible | current | A table of OTMn structure information. |
| 1.3.6.1.2.1.10.133.1.1.1.1 | RowoptIfOTMnEntry | not-accessible | current | A conceptual row that contains the OTMn structure information of an optical interface. |
| 1.3.6.1.2.1.10.133.1.1.1.1.1 | ColumnoptIfOTMnOrder | read-only | current | This object indicates the order of the OTM, which represents the maximum number of wavelengths that can be supported at the bit rate(s) supported on the interf… |
| 1.3.6.1.2.1.10.133.1.1.1.1.2 | ColumnoptIfOTMnReduced | read-only | current | This object indicates whether a reduced or full functionality is supported at the interface. A value of true means reduced. A value of false means full. |
| 1.3.6.1.2.1.10.133.1.1.1.1.3 | ColumnoptIfOTMnBitRates | read-only | current | This attribute is a bit map representing the bit rate or set of bit rates supported on the interface. The meaning of each bit position is as follows: bitRateK1… |
| 1.3.6.1.2.1.10.133.1.1.1.1.4 | ColumnoptIfOTMnInterfaceType | read-only | current | This object identifies the type of interface. The value of this attribute will affect the behavior of the OTM with respect to presence/absence of OTM Overhead … |
| 1.3.6.1.2.1.10.133.1.1.1.1.5 | ColumnoptIfOTMnTcmMax | read-write | current | This object identifies the maximum number of TCM levels allowed for any Optical Channel contained in this OTM. A new TCM activation will be rejected if the req… |
| 1.3.6.1.2.1.10.133.1.1.1.1.6 | ColumnoptIfOTMnOpticalReach | read-only | current | This object indicates the length the optical signal may travel before requiring termination or regeneration. The meaning of the enumeration are: intraOffice(1)… |
| 1.3.6.1.2.1.10.133.1.2 | NodeoptIfPerfMon | |||
| 1.3.6.1.2.1.10.133.1.2.1 | TableoptIfPerfMonIntervalTable | not-accessible | current | A table of 15-minute performance monitoring interval information. |
| 1.3.6.1.2.1.10.133.1.2.1.1 | RowoptIfPerfMonIntervalEntry | not-accessible | current | A conceptual row that contains 15-minute performance monitoring interval information of an interface. |
| 1.3.6.1.2.1.10.133.1.2.1.1.1 | ColumnoptIfPerfMonCurrentTimeElapsed | read-only | current | Number of seconds elapsed in the current 15-minute performance monitoring interval. If, for some reason, such as an adjustment in the NE's time-of-day clock, t… |
| 1.3.6.1.2.1.10.133.1.2.1.1.2 | ColumnoptIfPerfMonCurDayTimeElapsed | read-only | current | Number of seconds elapsed in the current 24-hour interval performance monitoring period. If, for some reason, such as an adjustment in the NE's time-of-day clo… |
| 1.3.6.1.2.1.10.133.1.2.1.1.3 | ColumnoptIfPerfMonIntervalNumIntervals | read-only | current | The number of 15-minute intervals for which performance monitoring data is available. The number is the same for all the associated sub layers of the interface… |
| 1.3.6.1.2.1.10.133.1.2.1.1.4 | ColumnoptIfPerfMonIntervalNumInvalidIntervals | read-only | current | The number of intervals in the range from 0 to optIfPerfMonIntervalNumIntervals for which no performance monitoring data is available and/or the data is invali… |
| 1.3.6.1.2.1.10.133.1.3 | NodeoptIfOTSn | |||
| 1.3.6.1.2.1.10.133.1.3.1 | TableoptIfOTSnConfigTable | not-accessible | current | A table of OTSn configuration information. |
| 1.3.6.1.2.1.10.133.1.3.1.1 | RowoptIfOTSnConfigEntry | not-accessible | current | A conceptual row that contains OTSn configuration information of an interface. |
| 1.3.6.1.2.1.10.133.1.3.1.1.1 | ColumnoptIfOTSnDirectionality | read-only | current | Indicates the directionality of the entity. |
| 1.3.6.1.2.1.10.133.1.3.1.1.2 | ColumnoptIfOTSnAprStatus | read-only | current | This attribute indicates the status of the Automatic Power Reduction (APR) function of the entity. Valid values are 'on' and 'off'. |
| 1.3.6.1.2.1.10.133.1.3.1.1.3 | ColumnoptIfOTSnAprControl | read-write | current | This object is a UTF-8 encoded string that specifies Automatic Power Reduction (APR) control actions requested of this entity (when written) and that returns t… |
| 1.3.6.1.2.1.10.133.1.3.1.1.4 | ColumnoptIfOTSnTraceIdentifierTransmitted | read-write | current | The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional(3). This object does not appl… |
| 1.3.6.1.2.1.10.133.1.3.1.1.5 | ColumnoptIfOTSnDAPIExpected | read-write | current | The DAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect if optIfO… |
| 1.3.6.1.2.1.10.133.1.3.1.1.6 | ColumnoptIfOTSnSAPIExpected | read-write | current | The SAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect if optIfO… |
| 1.3.6.1.2.1.10.133.1.3.1.1.7 | ColumnoptIfOTSnTraceIdentifierAccepted | read-only | current | The actual trace identifier received. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). Its value is unspecifie… |
| 1.3.6.1.2.1.10.133.1.3.1.1.8 | ColumnoptIfOTSnTIMDetMode | read-write | current | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable when optIfOTSnDirectionality has the value sink(1) or b… |
| 1.3.6.1.2.1.10.133.1.3.1.1.9 | ColumnoptIfOTSnTIMActEnabled | read-write | current | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable when optIfOTSnDirectionality has the val… |
| 1.3.6.1.2.1.10.133.1.3.1.1.10 | ColumnoptIfOTSnCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). In redu… |
| 1.3.6.1.2.1.10.133.1.3.2 | TableoptIfOTSnSinkCurrentTable | not-accessible | current | A table of OTSn sink performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.2.1 | RowoptIfOTSnSinkCurrentEntry | not-accessible | current | A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.2.1.1 | ColumnoptIfOTSnSinkCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.2.1.2 | ColumnoptIfOTSnSinkCurrentInputPower | read-only | current | The optical power monitored at the input. |
| 1.3.6.1.2.1.10.133.1.3.2.1.3 | ColumnoptIfOTSnSinkCurrentLowInputPower | read-only | current | The lowest optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.2.1.4 | ColumnoptIfOTSnSinkCurrentHighInputPower | read-only | current | The highest optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.2.1.5 | ColumnoptIfOTSnSinkCurrentLowerInputPowerThreshold | read-write | current | The lower limit threshold on input power. If optIfOTSnSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.2.1.6 | ColumnoptIfOTSnSinkCurrentUpperInputPowerThreshold | read-write | current | The upper limit threshold on input power. If optIfOTSnSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.2.1.7 | ColumnoptIfOTSnSinkCurrentOutputPower | read-only | current | The optical power monitored at the output. |
| 1.3.6.1.2.1.10.133.1.3.2.1.8 | ColumnoptIfOTSnSinkCurrentLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.2.1.9 | ColumnoptIfOTSnSinkCurrentHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.2.1.10 | ColumnoptIfOTSnSinkCurrentLowerOutputPowerThreshold | read-write | current | The lower limit threshold on output power. If optIfOTSnSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.2.1.11 | ColumnoptIfOTSnSinkCurrentUpperOutputPowerThreshold | read-write | current | The upper limit threshold on output power. If optIfOTSnSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.3 | TableoptIfOTSnSinkIntervalTable | not-accessible | current | A table of historical OTSn sink performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.3.3.1 | RowoptIfOTSnSinkIntervalEntry | not-accessible | current | A conceptual row that contains OTSn sink performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.3.3.1.1 | ColumnoptIfOTSnSinkIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.3.3.1.2 | ColumnoptIfOTSnSinkIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.3.1.3 | ColumnoptIfOTSnSinkIntervalLastInputPower | read-only | current | The last optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.3.3.1.4 | ColumnoptIfOTSnSinkIntervalLowInputPower | read-only | current | The lowest optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.3.3.1.5 | ColumnoptIfOTSnSinkIntervalHighInputPower | read-only | current | The highest optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.3.3.1.6 | ColumnoptIfOTSnSinkIntervalLastOutputPower | read-only | current | The last optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.3.3.1.7 | ColumnoptIfOTSnSinkIntervalLowOutputPower | read-only | current | The lowest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.3.3.1.8 | ColumnoptIfOTSnSinkIntervalHighOutputPower | read-only | current | The highest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.3.4 | TableoptIfOTSnSinkCurDayTable | not-accessible | current | A table of OTSn sink performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.4.1 | RowoptIfOTSnSinkCurDayEntry | not-accessible | current | A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.4.1.1 | ColumnoptIfOTSnSinkCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.4.1.2 | ColumnoptIfOTSnSinkCurDayLowInputPower | read-only | current | The lowest optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.4.1.3 | ColumnoptIfOTSnSinkCurDayHighInputPower | read-only | current | The highest optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.4.1.4 | ColumnoptIfOTSnSinkCurDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.4.1.5 | ColumnoptIfOTSnSinkCurDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5 | TableoptIfOTSnSinkPrevDayTable | not-accessible | current | A table of OTSn sink performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5.1 | RowoptIfOTSnSinkPrevDayEntry | not-accessible | current | A conceptual row that contains OTSn sink performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5.1.1 | ColumnoptIfOTSnSinkPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.5.1.2 | ColumnoptIfOTSnSinkPrevDayLastInputPower | read-only | current | The last optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5.1.3 | ColumnoptIfOTSnSinkPrevDayLowInputPower | read-only | current | The lowest optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5.1.4 | ColumnoptIfOTSnSinkPrevDayHighInputPower | read-only | current | The highest optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5.1.5 | ColumnoptIfOTSnSinkPrevDayLastOutputPower | read-only | current | The last optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5.1.6 | ColumnoptIfOTSnSinkPrevDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.5.1.7 | ColumnoptIfOTSnSinkPrevDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.6 | TableoptIfOTSnSrcCurrentTable | not-accessible | current | A table of OTSn source performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.6.1 | RowoptIfOTSnSrcCurrentEntry | not-accessible | current | A conceptual row that contains OTSn source performance monitoring information of an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.6.1.1 | ColumnoptIfOTSnSrcCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.6.1.2 | ColumnoptIfOTSnSrcCurrentOutputPower | read-only | current | The optical power monitored at the output. |
| 1.3.6.1.2.1.10.133.1.3.6.1.3 | ColumnoptIfOTSnSrcCurrentLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.6.1.4 | ColumnoptIfOTSnSrcCurrentHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.6.1.5 | ColumnoptIfOTSnSrcCurrentLowerOutputPowerThreshold | read-write | current | The lower limit threshold on output power. If optIfOTSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.6.1.6 | ColumnoptIfOTSnSrcCurrentUpperOutputPowerThreshold | read-write | current | The upper limit threshold on output power. If optIfOTSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.6.1.7 | ColumnoptIfOTSnSrcCurrentInputPower | read-only | current | The optical power monitored at the input. |
| 1.3.6.1.2.1.10.133.1.3.6.1.8 | ColumnoptIfOTSnSrcCurrentLowInputPower | read-only | current | The lowest optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.6.1.9 | ColumnoptIfOTSnSrcCurrentHighInputPower | read-only | current | The highest optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.3.6.1.10 | ColumnoptIfOTSnSrcCurrentLowerInputPowerThreshold | read-write | current | The lower limit threshold on input power. If optIfOTSnSrcCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.6.1.11 | ColumnoptIfOTSnSrcCurrentUpperInputPowerThreshold | read-write | current | The upper limit threshold on input power. If optIfOTSnSrcCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.3.7 | TableoptIfOTSnSrcIntervalTable | not-accessible | current | A table of historical OTSn source performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.3.7.1 | RowoptIfOTSnSrcIntervalEntry | not-accessible | current | A conceptual row that contains OTSn source performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.3.7.1.1 | ColumnoptIfOTSnSrcIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.3.7.1.2 | ColumnoptIfOTSnSrcIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.7.1.3 | ColumnoptIfOTSnSrcIntervalLastOutputPower | read-only | current | The last optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.3.7.1.4 | ColumnoptIfOTSnSrcIntervalLowOutputPower | read-only | current | The lowest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.3.7.1.5 | ColumnoptIfOTSnSrcIntervalHighOutputPower | read-only | current | The highest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.3.7.1.6 | ColumnoptIfOTSnSrcIntervalLastInputPower | read-only | current | The last optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.3.7.1.7 | ColumnoptIfOTSnSrcIntervalLowInputPower | read-only | current | The lowest optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.3.7.1.8 | ColumnoptIfOTSnSrcIntervalHighInputPower | read-only | current | The highest optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.3.8 | TableoptIfOTSnSrcCurDayTable | not-accessible | current | A table of OTSn source performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.8.1 | RowoptIfOTSnSrcCurDayEntry | not-accessible | current | A conceptual row that contains OTSn source performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.8.1.1 | ColumnoptIfOTSnSrcCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.8.1.2 | ColumnoptIfOTSnSrcCurDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.8.1.3 | ColumnoptIfOTSnSrcCurDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.8.1.4 | ColumnoptIfOTSnSrcCurDayLowInputPower | read-only | current | The lowest optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.8.1.5 | ColumnoptIfOTSnSrcCurDayHighInputPower | read-only | current | The highest optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9 | TableoptIfOTSnSrcPrevDayTable | not-accessible | current | A table of OTSn source performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9.1 | RowoptIfOTSnSrcPrevDayEntry | not-accessible | current | A conceptual row that contains OTSn source performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9.1.1 | ColumnoptIfOTSnSrcPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.3.9.1.2 | ColumnoptIfOTSnSrcPrevDayLastOutputPower | read-only | current | The last optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9.1.3 | ColumnoptIfOTSnSrcPrevDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9.1.4 | ColumnoptIfOTSnSrcPrevDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9.1.5 | ColumnoptIfOTSnSrcPrevDayLastInputPower | read-only | current | The last optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9.1.6 | ColumnoptIfOTSnSrcPrevDayLowInputPower | read-only | current | The lowest optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.3.9.1.7 | ColumnoptIfOTSnSrcPrevDayHighInputPower | read-only | current | The highest optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4 | NodeoptIfOMSn | |||
| 1.3.6.1.2.1.10.133.1.4.1 | TableoptIfOMSnConfigTable | not-accessible | current | A table of OMSn configuration information. |
| 1.3.6.1.2.1.10.133.1.4.1.1 | RowoptIfOMSnConfigEntry | not-accessible | current | A conceptual row that contains OMSn configuration information of an interface. |
| 1.3.6.1.2.1.10.133.1.4.1.1.1 | ColumnoptIfOMSnDirectionality | read-only | current | Indicates the directionality of the entity. |
| 1.3.6.1.2.1.10.133.1.4.1.1.2 | ColumnoptIfOMSnCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. This object is applicable only to full capability systems whose interface type is IaDI and for which optI… |
| 1.3.6.1.2.1.10.133.1.4.2 | TableoptIfOMSnSinkCurrentTable | not-accessible | current | A table of OMSn sink performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.2.1 | RowoptIfOMSnSinkCurrentEntry | not-accessible | current | A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.2.1.1 | ColumnoptIfOMSnSinkCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.2.1.2 | ColumnoptIfOMSnSinkCurrentAggregatedInputPower | read-only | current | The aggregated optical power of all the DWDM input channels. |
| 1.3.6.1.2.1.10.133.1.4.2.1.3 | ColumnoptIfOMSnSinkCurrentLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.2.1.4 | ColumnoptIfOMSnSinkCurrentHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.2.1.5 | ColumnoptIfOMSnSinkCurrentLowerInputPowerThreshold | read-write | current | The lower limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA)… |
| 1.3.6.1.2.1.10.133.1.4.2.1.6 | ColumnoptIfOMSnSinkCurrentUpperInputPowerThreshold | read-write | current | The upper limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA… |
| 1.3.6.1.2.1.10.133.1.4.2.1.7 | ColumnoptIfOMSnSinkCurrentOutputPower | read-only | current | The optical power monitored at the output. |
| 1.3.6.1.2.1.10.133.1.4.2.1.8 | ColumnoptIfOMSnSinkCurrentLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.2.1.9 | ColumnoptIfOMSnSinkCurrentHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.2.1.10 | ColumnoptIfOMSnSinkCurrentLowerOutputPowerThreshold | read-write | current | The lower limit threshold on output power. If optIfOMSnSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.4.2.1.11 | ColumnoptIfOMSnSinkCurrentUpperOutputPowerThreshold | read-write | current | The upper limit threshold on output power. If optIfOMSnSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.4.3 | TableoptIfOMSnSinkIntervalTable | not-accessible | current | A table of historical OMSn sink performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.4.3.1 | RowoptIfOMSnSinkIntervalEntry | not-accessible | current | A conceptual row that contains OMSn sink performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.4.3.1.1 | ColumnoptIfOMSnSinkIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.4.3.1.2 | ColumnoptIfOMSnSinkIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.3.1.3 | ColumnoptIfOMSnSinkIntervalLastAggregatedInputPower | read-only | current | The last aggregated optical power of all the DWDM input channels during the interval. |
| 1.3.6.1.2.1.10.133.1.4.3.1.4 | ColumnoptIfOMSnSinkIntervalLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels during the interval. |
| 1.3.6.1.2.1.10.133.1.4.3.1.5 | ColumnoptIfOMSnSinkIntervalHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels during the interval. |
| 1.3.6.1.2.1.10.133.1.4.3.1.6 | ColumnoptIfOMSnSinkIntervalLastOutputPower | read-only | current | The last optical power at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.4.3.1.7 | ColumnoptIfOMSnSinkIntervalLowOutputPower | read-only | current | The lowest optical power at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.4.3.1.8 | ColumnoptIfOMSnSinkIntervalHighOutputPower | read-only | current | The highest optical power at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.4.4 | TableoptIfOMSnSinkCurDayTable | not-accessible | current | A table of OMSn sink performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.4.1 | RowoptIfOMSnSinkCurDayEntry | not-accessible | current | A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.4.1.1 | ColumnoptIfOMSnSinkCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.4.1.2 | ColumnoptIfOMSnSinkCurDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.4.1.3 | ColumnoptIfOMSnSinkCurDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.4.1.4 | ColumnoptIfOMSnSinkCurDayLowOutputPower | read-only | current | The lowest optical power at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.4.1.5 | ColumnoptIfOMSnSinkCurDayHighOutputPower | read-only | current | The highest optical power at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5 | TableoptIfOMSnSinkPrevDayTable | not-accessible | current | A table of OMSn sink performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5.1 | RowoptIfOMSnSinkPrevDayEntry | not-accessible | current | A conceptual row that contains OMSn sink performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5.1.1 | ColumnoptIfOMSnSinkPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.5.1.2 | ColumnoptIfOMSnSinkPrevDayLastAggregatedInputPower | read-only | current | The last aggregated optical power of all the DWDM input channels during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5.1.3 | ColumnoptIfOMSnSinkPrevDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5.1.4 | ColumnoptIfOMSnSinkPrevDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5.1.5 | ColumnoptIfOMSnSinkPrevDayLastOutputPower | read-only | current | The last optical power at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5.1.6 | ColumnoptIfOMSnSinkPrevDayLowOutputPower | read-only | current | The lowest optical power at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.5.1.7 | ColumnoptIfOMSnSinkPrevDayHighOutputPower | read-only | current | The highest optical power at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.6 | TableoptIfOMSnSrcCurrentTable | not-accessible | current | A table of OMSn source performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.6.1 | RowoptIfOMSnSrcCurrentEntry | not-accessible | current | A conceptual row that contains OMSn source performance monitoring information of an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.6.1.1 | ColumnoptIfOMSnSrcCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.6.1.2 | ColumnoptIfOMSnSrcCurrentOutputPower | read-only | current | The optical power monitored at the output. |
| 1.3.6.1.2.1.10.133.1.4.6.1.3 | ColumnoptIfOMSnSrcCurrentLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.6.1.4 | ColumnoptIfOMSnSrcCurrentHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.6.1.5 | ColumnoptIfOMSnSrcCurrentLowerOutputPowerThreshold | read-write | current | The lower limit threshold on output power. If optIfOMSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.4.6.1.6 | ColumnoptIfOMSnSrcCurrentUpperOutputPowerThreshold | read-write | current | The upper limit threshold on output power. If optIfOMSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.4.6.1.7 | ColumnoptIfOMSnSrcCurrentAggregatedInputPower | read-only | current | The aggregated optical power at the input. |
| 1.3.6.1.2.1.10.133.1.4.6.1.8 | ColumnoptIfOMSnSrcCurrentLowAggregatedInputPower | read-only | current | The lowest aggregated optical power at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.6.1.9 | ColumnoptIfOMSnSrcCurrentHighAggregatedInputPower | read-only | current | The highest aggregated optical power at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.4.6.1.10 | ColumnoptIfOMSnSrcCurrentLowerInputPowerThreshold | read-write | current | The lower limit threshold on aggregated input power. If optIfOMSnSrcCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) … |
| 1.3.6.1.2.1.10.133.1.4.6.1.11 | ColumnoptIfOMSnSrcCurrentUpperInputPowerThreshold | read-write | current | The upper limit threshold on aggregated input power. If optIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA)… |
| 1.3.6.1.2.1.10.133.1.4.7 | TableoptIfOMSnSrcIntervalTable | not-accessible | current | A table of historical OMSn source performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.4.7.1 | RowoptIfOMSnSrcIntervalEntry | not-accessible | current | A conceptual row that contains OMSn source performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.4.7.1.1 | ColumnoptIfOMSnSrcIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.4.7.1.2 | ColumnoptIfOMSnSrcIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.7.1.3 | ColumnoptIfOMSnSrcIntervalLastOutputPower | read-only | current | The last optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.4.7.1.4 | ColumnoptIfOMSnSrcIntervalLowOutputPower | read-only | current | The lowest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.4.7.1.5 | ColumnoptIfOMSnSrcIntervalHighOutputPower | read-only | current | The highest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.4.7.1.6 | ColumnoptIfOMSnSrcIntervalLastAggregatedInputPower | read-only | current | The last aggregated optical power at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.4.7.1.7 | ColumnoptIfOMSnSrcIntervalLowAggregatedInputPower | read-only | current | The lowest aggregated optical power at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.4.7.1.8 | ColumnoptIfOMSnSrcIntervalHighAggregatedInputPower | read-only | current | The highest aggregated optical power at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.4.8 | TableoptIfOMSnSrcCurDayTable | not-accessible | current | A table of OMSn source performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.8.1 | RowoptIfOMSnSrcCurDayEntry | not-accessible | current | A conceptual row that contains OMSn source performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.8.1.1 | ColumnoptIfOMSnSrcCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.8.1.2 | ColumnoptIfOMSnSrcCurDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.8.1.3 | ColumnoptIfOMSnSrcCurDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.8.1.4 | ColumnoptIfOMSnSrcCurDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.8.1.5 | ColumnoptIfOMSnSrcCurDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9 | TableoptIfOMSnSrcPrevDayTable | not-accessible | current | A table of OMSn source performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9.1 | RowoptIfOMSnSrcPrevDayEntry | not-accessible | current | A conceptual row that contains OMSn source performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9.1.1 | ColumnoptIfOMSnSrcPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.4.9.1.2 | ColumnoptIfOMSnSrcPrevDayLastOutputPower | read-only | current | The last optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9.1.3 | ColumnoptIfOMSnSrcPrevDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9.1.4 | ColumnoptIfOMSnSrcPrevDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9.1.5 | ColumnoptIfOMSnSrcPrevDayLastAggregatedInputPower | read-only | current | The last aggregated optical power at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9.1.6 | ColumnoptIfOMSnSrcPrevDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.4.9.1.7 | ColumnoptIfOMSnSrcPrevDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5 | NodeoptIfOChGroup | |||
| 1.3.6.1.2.1.10.133.1.5.1 | TableoptIfOChGroupConfigTable | not-accessible | current | A table of OChGroup configuration information. |
| 1.3.6.1.2.1.10.133.1.5.1.1 | RowoptIfOChGroupConfigEntry | not-accessible | current | A conceptual row that contains OChGroup configuration information of an interface. |
| 1.3.6.1.2.1.10.133.1.5.1.1.1 | ColumnoptIfOChGroupDirectionality | read-only | current | Indicates the directionality of the entity. |
| 1.3.6.1.2.1.10.133.1.5.2 | TableoptIfOChGroupSinkCurrentTable | not-accessible | current | A table of OChGroup sink performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.2.1 | RowoptIfOChGroupSinkCurrentEntry | not-accessible | current | A conceptual row that contains OChGroup sink performance monitoring information of an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.2.1.1 | ColumnoptIfOChGroupSinkCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.2.1.2 | ColumnoptIfOChGroupSinkCurrentAggregatedInputPower | read-only | current | The aggregated optical power of all the DWDM input channels in the OChGroup. |
| 1.3.6.1.2.1.10.133.1.5.2.1.3 | ColumnoptIfOChGroupSinkCurrentLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.2.1.4 | ColumnoptIfOChGroupSinkCurrentHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.2.1.5 | ColumnoptIfOChGroupSinkCurrentLowerInputPowerThreshold | read-write | current | The lower limit threshold on aggregated input power. If optIfOChGroupSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (… |
| 1.3.6.1.2.1.10.133.1.5.2.1.6 | ColumnoptIfOChGroupSinkCurrentUpperInputPowerThreshold | read-write | current | The upper limit threshold on aggregated input power. If optIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert … |
| 1.3.6.1.2.1.10.133.1.5.2.1.7 | ColumnoptIfOChGroupSinkCurrentOutputPower | read-only | current | The optical power monitored at the output in the OChGroup. |
| 1.3.6.1.2.1.10.133.1.5.2.1.8 | ColumnoptIfOChGroupSinkCurrentLowOutputPower | read-only | current | The lowest optical power monitored at the output in the OChGroup during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.2.1.9 | ColumnoptIfOChGroupSinkCurrentHighOutputPower | read-only | current | The highest optical power monitored at the output in the OChGroup during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.2.1.10 | ColumnoptIfOChGroupSinkCurrentLowerOutputPowerThreshold | read-write | current | The lower limit threshold on the output power. If optIfOChGroupSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be … |
| 1.3.6.1.2.1.10.133.1.5.2.1.11 | ColumnoptIfOChGroupSinkCurrentUpperOutputPowerThreshold | read-write | current | The upper limit threshold on the output power. If optIfOChGroupSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be… |
| 1.3.6.1.2.1.10.133.1.5.3 | TableoptIfOChGroupSinkIntervalTable | not-accessible | current | A table of historical OChGroup sink performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.5.3.1 | RowoptIfOChGroupSinkIntervalEntry | not-accessible | current | A conceptual row that contains OChGroup sink performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.5.3.1.1 | ColumnoptIfOChGroupSinkIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.5.3.1.2 | ColumnoptIfOChGroupSinkIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.3.1.3 | ColumnoptIfOChGroupSinkIntervalLastAggregatedInputPower | read-only | current | The last aggregated optical power of all the DWDM input channels in the OChGroup during the interval. |
| 1.3.6.1.2.1.10.133.1.5.3.1.4 | ColumnoptIfOChGroupSinkIntervalLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the interval. |
| 1.3.6.1.2.1.10.133.1.5.3.1.5 | ColumnoptIfOChGroupSinkIntervalHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the interval. |
| 1.3.6.1.2.1.10.133.1.5.3.1.6 | ColumnoptIfOChGroupSinkIntervalLastOutputPower | read-only | current | The last optical power monitored at the output in the OChGroup during the interval. |
| 1.3.6.1.2.1.10.133.1.5.3.1.7 | ColumnoptIfOChGroupSinkIntervalLowOutputPower | read-only | current | The lowest optical power monitored at the output in the OChGroup during the interval. |
| 1.3.6.1.2.1.10.133.1.5.3.1.8 | ColumnoptIfOChGroupSinkIntervalHighOutputPower | read-only | current | The highest optical power monitored at the output in the OChGroup during the interval. |
| 1.3.6.1.2.1.10.133.1.5.4 | TableoptIfOChGroupSinkCurDayTable | not-accessible | current | A table of OChGroup sink performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.4.1 | RowoptIfOChGroupSinkCurDayEntry | not-accessible | current | A conceptual row that contains OChGroup sink performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.4.1.1 | ColumnoptIfOChGroupSinkCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.4.1.2 | ColumnoptIfOChGroupSinkCurDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.4.1.3 | ColumnoptIfOChGroupSinkCurDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.4.1.4 | ColumnoptIfOChGroupSinkCurDayLowOutputPower | read-only | current | The lowest optical power monitored at the output in the OChGroup during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.4.1.5 | ColumnoptIfOChGroupSinkCurDayHighOutputPower | read-only | current | The highest optical power monitored at the output in the OChGroup during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5 | TableoptIfOChGroupSinkPrevDayTable | not-accessible | current | A table of OChGroup sink performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5.1 | RowoptIfOChGroupSinkPrevDayEntry | not-accessible | current | A conceptual row that contains OChGroup sink performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5.1.1 | ColumnoptIfOChGroupSinkPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.5.1.2 | ColumnoptIfOChGroupSinkPrevDayLastAggregatedInputPower | read-only | current | The last aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5.1.3 | ColumnoptIfOChGroupSinkPrevDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5.1.4 | ColumnoptIfOChGroupSinkPrevDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5.1.5 | ColumnoptIfOChGroupSinkPrevDayLastOutputPower | read-only | current | The last optical power monitored at the output in the OChGroup during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5.1.6 | ColumnoptIfOChGroupSinkPrevDayLowOutputPower | read-only | current | The lowest optical power monitored at the output in the OChGroup during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.5.1.7 | ColumnoptIfOChGroupSinkPrevDayHighOutputPower | read-only | current | The highest optical power monitored at the output in the OChGroup during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.6 | TableoptIfOChGroupSrcCurrentTable | not-accessible | current | A table of OChGroup source performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.6.1 | RowoptIfOChGroupSrcCurrentEntry | not-accessible | current | A conceptual row that contains OChGroup source performance monitoring information of an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.6.1.1 | ColumnoptIfOChGroupSrcCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.6.1.2 | ColumnoptIfOChGroupSrcCurrentOutputPower | read-only | current | The optical power monitored at the output. |
| 1.3.6.1.2.1.10.133.1.5.6.1.3 | ColumnoptIfOChGroupSrcCurrentLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.6.1.4 | ColumnoptIfOChGroupSrcCurrentHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.6.1.5 | ColumnoptIfOChGroupSrcCurrentLowerOutputPowerThreshold | read-write | current | The lower limit threshold on output power. If optIfOChGroupSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.5.6.1.6 | ColumnoptIfOChGroupSrcCurrentUpperOutputPowerThreshold | read-write | current | The upper limit threshold on output power. If optIfOChGroupSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.5.6.1.7 | ColumnoptIfOChGroupSrcCurrentAggregatedInputPower | read-only | current | The aggregated optical power monitored at the input. |
| 1.3.6.1.2.1.10.133.1.5.6.1.8 | ColumnoptIfOChGroupSrcCurrentLowAggregatedInputPower | read-only | current | The lowest aggregated optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.6.1.9 | ColumnoptIfOChGroupSrcCurrentHighAggregatedInputPower | read-only | current | The highest aggregated optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.5.6.1.10 | ColumnoptIfOChGroupSrcCurrentLowerInputPowerThreshold | read-write | current | The lower limit threshold on input power. If optIfOChGroupSrcCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should … |
| 1.3.6.1.2.1.10.133.1.5.6.1.11 | ColumnoptIfOChGroupSrcCurrentUpperInputPowerThreshold | read-write | current | The upper limit threshold on input power. If optIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should… |
| 1.3.6.1.2.1.10.133.1.5.7 | TableoptIfOChGroupSrcIntervalTable | not-accessible | current | A table of historical OChGroup source performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.5.7.1 | RowoptIfOChGroupSrcIntervalEntry | not-accessible | current | A conceptual row that contains OChGroup source performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.5.7.1.1 | ColumnoptIfOChGroupSrcIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.5.7.1.2 | ColumnoptIfOChGroupSrcIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.7.1.3 | ColumnoptIfOChGroupSrcIntervalLastOutputPower | read-only | current | The last optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.5.7.1.4 | ColumnoptIfOChGroupSrcIntervalLowOutputPower | read-only | current | The lowest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.5.7.1.5 | ColumnoptIfOChGroupSrcIntervalHighOutputPower | read-only | current | The highest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.5.7.1.6 | ColumnoptIfOChGroupSrcIntervalLastAggregatedInputPower | read-only | current | The last aggregated optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.5.7.1.7 | ColumnoptIfOChGroupSrcIntervalLowAggregatedInputPower | read-only | current | The lowest aggregated optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.5.7.1.8 | ColumnoptIfOChGroupSrcIntervalHighAggregatedInputPower | read-only | current | The highest aggregated optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.5.8 | TableoptIfOChGroupSrcCurDayTable | not-accessible | current | A table of OChGroup source performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.8.1 | RowoptIfOChGroupSrcCurDayEntry | not-accessible | current | A conceptual row that contains OChGroup source performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.8.1.1 | ColumnoptIfOChGroupSrcCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.8.1.2 | ColumnoptIfOChGroupSrcCurDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.8.1.3 | ColumnoptIfOChGroupSrcCurDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.8.1.4 | ColumnoptIfOChGroupSrcCurDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.8.1.5 | ColumnoptIfOChGroupSrcCurDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9 | TableoptIfOChGroupSrcPrevDayTable | not-accessible | current | A table of OChGroup source performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9.1 | RowoptIfOChGroupSrcPrevDayEntry | not-accessible | current | A conceptual row that contains OChGroup source performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9.1.1 | ColumnoptIfOChGroupSrcPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.5.9.1.2 | ColumnoptIfOChGroupSrcPrevDayLastOutputPower | read-only | current | The last optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9.1.3 | ColumnoptIfOChGroupSrcPrevDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9.1.4 | ColumnoptIfOChGroupSrcPrevDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9.1.5 | ColumnoptIfOChGroupSrcPrevDayLastAggregatedInputPower | read-only | current | The last aggregated optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9.1.6 | ColumnoptIfOChGroupSrcPrevDayLowAggregatedInputPower | read-only | current | The lowest aggregated optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.5.9.1.7 | ColumnoptIfOChGroupSrcPrevDayHighAggregatedInputPower | read-only | current | The highest aggregated optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6 | NodeoptIfOCh | |||
| 1.3.6.1.2.1.10.133.1.6.1 | TableoptIfOChConfigTable | not-accessible | current | A table of OCh configuration information. |
| 1.3.6.1.2.1.10.133.1.6.1.1 | RowoptIfOChConfigEntry | not-accessible | current | A conceptual row that contains OCh configuration information of an interface. |
| 1.3.6.1.2.1.10.133.1.6.1.1.1 | ColumnoptIfOChDirectionality | read-only | current | Indicates the directionality of the entity. |
| 1.3.6.1.2.1.10.133.1.6.1.1.2 | ColumnoptIfOChCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. This object is applicable when optIfOChDirectionality has the value sink(1) or bidirectional(3). In full-… |
| 1.3.6.1.2.1.10.133.1.6.2 | TableoptIfOChSinkCurrentTable | not-accessible | current | A table of OCh sink performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.2.1 | RowoptIfOChSinkCurrentEntry | not-accessible | current | A conceptual row that contains OCh sink performance monitoring information for an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.2.1.1 | ColumnoptIfOChSinkCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.2.1.2 | ColumnoptIfOChSinkCurrentInputPower | read-only | current | The optical power monitored at the input. |
| 1.3.6.1.2.1.10.133.1.6.2.1.3 | ColumnoptIfOChSinkCurrentLowInputPower | read-only | current | The lowest optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.2.1.4 | ColumnoptIfOChSinkCurrentHighInputPower | read-only | current | The highest optical power monitored at the input during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.2.1.5 | ColumnoptIfOChSinkCurrentLowerInputPowerThreshold | read-write | current | The lower limit threshold on input power. If optIfOChSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.6.2.1.6 | ColumnoptIfOChSinkCurrentUpperInputPowerThreshold | read-write | current | The upper limit threshold on input power. If optIfOChSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.6.3 | TableoptIfOChSinkIntervalTable | not-accessible | current | A table of historical OCh sink performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.6.3.1 | RowoptIfOChSinkIntervalEntry | not-accessible | current | A conceptual row that contains OCh sink performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.6.3.1.1 | ColumnoptIfOChSinkIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.6.3.1.2 | ColumnoptIfOChSinkIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.3.1.3 | ColumnoptIfOChSinkIntervalLastInputPower | read-only | current | The last optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.6.3.1.4 | ColumnoptIfOChSinkIntervalLowInputPower | read-only | current | The lowest optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.6.3.1.5 | ColumnoptIfOChSinkIntervalHighInputPower | read-only | current | The highest optical power monitored at the input during the interval. |
| 1.3.6.1.2.1.10.133.1.6.4 | TableoptIfOChSinkCurDayTable | not-accessible | current | A table of OCh sink performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.4.1 | RowoptIfOChSinkCurDayEntry | not-accessible | current | A conceptual row that contains OCh sink performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.4.1.1 | ColumnoptIfOChSinkCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.4.1.2 | ColumnoptIfOChSinkCurDayLowInputPower | read-only | current | The lowest optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.4.1.3 | ColumnoptIfOChSinkCurDayHighInputPower | read-only | current | The highest optical power monitored at the input during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.5 | TableoptIfOChSinkPrevDayTable | not-accessible | current | A table of OCh sink performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.5.1 | RowoptIfOChSinkPrevDayEntry | not-accessible | current | A conceptual row that contains OCh sink performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.5.1.1 | ColumnoptIfOChSinkPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.5.1.2 | ColumnoptIfOChSinkPrevDayLastInputPower | read-only | current | The last optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.5.1.3 | ColumnoptIfOChSinkPrevDayLowInputPower | read-only | current | The lowest optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.5.1.4 | ColumnoptIfOChSinkPrevDayHighInputPower | read-only | current | The highest optical power monitored at the input during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.6 | TableoptIfOChSrcCurrentTable | not-accessible | current | A table of OCh source performance monitoring information for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.6.1 | RowoptIfOChSrcCurrentEntry | not-accessible | current | A conceptual row that contains OCh source performance monitoring information of an interface for the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.6.1.1 | ColumnoptIfOChSrcCurrentSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.6.1.2 | ColumnoptIfOChSrcCurrentOutputPower | read-only | current | The optical power monitored at the output. |
| 1.3.6.1.2.1.10.133.1.6.6.1.3 | ColumnoptIfOChSrcCurrentLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.6.1.4 | ColumnoptIfOChSrcCurrentHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 15-minute interval. |
| 1.3.6.1.2.1.10.133.1.6.6.1.5 | ColumnoptIfOChSrcCurrentLowerOutputPowerThreshold | read-write | current | The lower limit threshold on output power. If optIfOChSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.6.6.1.6 | ColumnoptIfOChSrcCurrentUpperOutputPowerThreshold | read-write | current | The upper limit threshold on output power. If optIfOChSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| 1.3.6.1.2.1.10.133.1.6.7 | TableoptIfOChSrcIntervalTable | not-accessible | current | A table of historical OCh source performance monitoring information. |
| 1.3.6.1.2.1.10.133.1.6.7.1 | RowoptIfOChSrcIntervalEntry | not-accessible | current | A conceptual row that contains OCh source performance monitoring information of an interface during a particular historical interval. |
| 1.3.6.1.2.1.10.133.1.6.7.1.1 | ColumnoptIfOChSrcIntervalNumber | not-accessible | current | Uniquely identifies the interval. |
| 1.3.6.1.2.1.10.133.1.6.7.1.2 | ColumnoptIfOChSrcIntervalSuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.7.1.3 | ColumnoptIfOChSrcIntervalLastOutputPower | read-only | current | The last optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.6.7.1.4 | ColumnoptIfOChSrcIntervalLowOutputPower | read-only | current | The lowest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.6.7.1.5 | ColumnoptIfOChSrcIntervalHighOutputPower | read-only | current | The highest optical power monitored at the output during the interval. |
| 1.3.6.1.2.1.10.133.1.6.8 | TableoptIfOChSrcCurDayTable | not-accessible | current | A table of OCh source performance monitoring information for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.8.1 | RowoptIfOChSrcCurDayEntry | not-accessible | current | A conceptual row that contains OCh source performance monitoring information of an interface for the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.8.1.1 | ColumnoptIfOChSrcCurDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.8.1.2 | ColumnoptIfOChSrcCurDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.8.1.3 | ColumnoptIfOChSrcCurDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the current 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.9 | TableoptIfOChSrcPrevDayTable | not-accessible | current | A table of OCh source performance monitoring information for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.9.1 | RowoptIfOChSrcPrevDayEntry | not-accessible | current | A conceptual row that contains OCh source performance monitoring information of an interface for the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.9.1.1 | ColumnoptIfOChSrcPrevDaySuspectedFlag | read-only | current | If true, the data in this entry may be unreliable. |
| 1.3.6.1.2.1.10.133.1.6.9.1.2 | ColumnoptIfOChSrcPrevDayLastOutputPower | read-only | current | The last optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.9.1.3 | ColumnoptIfOChSrcPrevDayLowOutputPower | read-only | current | The lowest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.6.9.1.4 | ColumnoptIfOChSrcPrevDayHighOutputPower | read-only | current | The highest optical power monitored at the output during the previous 24-hour interval. |
| 1.3.6.1.2.1.10.133.1.7 | NodeoptIfOTUk | |||
| 1.3.6.1.2.1.10.133.1.7.1 | TableoptIfOTUkConfigTable | not-accessible | current | A table of OTUk configuration information. |
| 1.3.6.1.2.1.10.133.1.7.1.1 | RowoptIfOTUkConfigEntry | not-accessible | current | A conceptual row that contains OTUk configuration information of an interface. |
| 1.3.6.1.2.1.10.133.1.7.1.1.1 | ColumnoptIfOTUkDirectionality | read-only | current | Indicates the directionality of the entity. |
| 1.3.6.1.2.1.10.133.1.7.1.1.2 | ColumnoptIfOTUkBitRateK | read-only | current | Indicates the bit rate of the entity. |
| 1.3.6.1.2.1.10.133.1.7.1.1.3 | ColumnoptIfOTUkTraceIdentifierTransmitted | read-write | current | The trace identifier transmitted. This object is applicable when optIfOTUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiat… |
| 1.3.6.1.2.1.10.133.1.7.1.1.4 | ColumnoptIfOTUkDAPIExpected | read-write | current | The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidire… |
| 1.3.6.1.2.1.10.133.1.7.1.1.5 | ColumnoptIfOTUkSAPIExpected | read-write | current | The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidire… |
| 1.3.6.1.2.1.10.133.1.7.1.1.6 | ColumnoptIfOTUkTraceIdentifierAccepted | read-only | current | The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bid… |
| 1.3.6.1.2.1.10.133.1.7.1.1.7 | ColumnoptIfOTUkTIMDetMode | read-write | current | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function, i.e., only when optIfOTUkDir… |
| 1.3.6.1.2.1.10.133.1.7.1.1.8 | ColumnoptIfOTUkTIMActEnabled | read-write | current | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to the sink function, i.e., only wh… |
| 1.3.6.1.2.1.10.133.1.7.1.1.9 | ColumnoptIfOTUkDEGThr | read-write | current | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored b… |
| 1.3.6.1.2.1.10.133.1.7.1.1.10 | ColumnoptIfOTUkDEGM | read-write | current | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfOTUkDEGM consecutive bad PM Seconds are detected.… |
| 1.3.6.1.2.1.10.133.1.7.1.1.11 | ColumnoptIfOTUkSinkAdaptActive | read-write | current | Indicates whether the sink adaptation function is activated or not. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionalit… |
| 1.3.6.1.2.1.10.133.1.7.1.1.12 | ColumnoptIfOTUkSourceAdaptActive | read-write | current | Indicates whether the source adaptation function is activated or not. This object is only applicable to the source function, i.e., only when optIfOTUkDirection… |
| 1.3.6.1.2.1.10.133.1.7.1.1.13 | ColumnoptIfOTUkSinkFECEnabled | read-write | current | If Forward Error Correction (FEC) is supported, this object indicates whether FEC at the OTUk sink adaptation function is enabled or not. This object is only a… |
| 1.3.6.1.2.1.10.133.1.7.1.1.14 | ColumnoptIfOTUkCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the valu… |
| 1.3.6.1.2.1.10.133.1.7.2 | TableoptIfGCC0ConfigTable | not-accessible | current | A table of GCC0 configuration information. |
| 1.3.6.1.2.1.10.133.1.7.2.1 | RowoptIfGCC0ConfigEntry | not-accessible | current | A conceptual row that contains GCC0 configuration information of an interface. Each instance must correspond to an instance of optIfOTUkConfigEntry. Separate s… |
| 1.3.6.1.2.1.10.133.1.7.2.1.1 | ColumnoptIfGCC0Directionality | not-accessible | current | Indicates the directionality of the entity. The values source(2) and bidirectional(3) are not allowed if the corresponding instance of optIfOTUkDirectionality … |
| 1.3.6.1.2.1.10.133.1.7.2.1.2 | ColumnoptIfGCC0Application | read-create | current | Indicates the application transported by the GCC0 entity. Example applications are ECC, User data channel. The value of this object may not be changed when opt… |
| 1.3.6.1.2.1.10.133.1.7.2.1.3 | ColumnoptIfGCC0RowStatus | read-create | current | This columnar object is used for creating and deleting a conceptual row of the optIfGCC0 config table. It is used to model the addGCC0Access and removeGCC0Acce… |
| 1.3.6.1.2.1.10.133.1.8 | NodeoptIfODUk | |||
| 1.3.6.1.2.1.10.133.1.8.1 | TableoptIfODUkConfigTable | not-accessible | current | A table of ODUk configuration information. |
| 1.3.6.1.2.1.10.133.1.8.1.1 | RowoptIfODUkConfigEntry | not-accessible | current | A conceptual row that contains ODUk configuration information of an interface. |
| 1.3.6.1.2.1.10.133.1.8.1.1.1 | ColumnoptIfODUkDirectionality | read-only | current | Indicates the directionality of the entity. |
| 1.3.6.1.2.1.10.133.1.8.1.1.2 | ColumnoptIfODUkBitRateK | read-only | current | Indicates the bit rate of the entity. |
| 1.3.6.1.2.1.10.133.1.8.1.1.3 | ColumnoptIfODUkTcmFieldsInUse | read-only | current | Indicates the TCM field(s) that are currently in use. The positions of the bits correspond to the TCM fields. A bit that is set to 1 means that the correspondi… |
| 1.3.6.1.2.1.10.133.1.8.1.1.4 | ColumnoptIfODUkPositionSeqCurrentSize | read-only | current | This variable indicates the current size of the position sequence (i.e., number of TCM function and/or GCC12 access that have been created in the ODUk interfac… |
| 1.3.6.1.2.1.10.133.1.8.1.1.5 | ColumnoptIfODUkTtpPresent | read-only | current | This object has the value true(1) if the ifEntry under which it is instantiated contains an ODUk Trail Termination Point, i.e., is the endpoint of an ODUk path… |
| 1.3.6.1.2.1.10.133.1.8.2 | TableoptIfODUkTtpConfigTable | not-accessible | current | A table of ODUk TTP configuration information. |
| 1.3.6.1.2.1.10.133.1.8.2.1 | RowoptIfODUkTtpConfigEntry | not-accessible | current | A conceptual row that contains ODUk TTP configuration information of an interface. |
| 1.3.6.1.2.1.10.133.1.8.2.1.1 | ColumnoptIfODUkTtpTraceIdentifierTransmitted | read-write | current | The trace identifier transmitted. This object is applicable when optIfODUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiat… |
| 1.3.6.1.2.1.10.133.1.8.2.1.2 | ColumnoptIfODUkTtpDAPIExpected | read-write | current | The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidire… |
| 1.3.6.1.2.1.10.133.1.8.2.1.3 | ColumnoptIfODUkTtpSAPIExpected | read-write | current | The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidire… |
| 1.3.6.1.2.1.10.133.1.8.2.1.4 | ColumnoptIfODUkTtpTraceIdentifierAccepted | read-only | current | The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bid… |
| 1.3.6.1.2.1.10.133.1.8.2.1.5 | ColumnoptIfODUkTtpTIMDetMode | read-write | current | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function, i.e., only when optIfODUkDir… |
| 1.3.6.1.2.1.10.133.1.8.2.1.6 | ColumnoptIfODUkTtpTIMActEnabled | read-write | current | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to the sink function, i.e., only wh… |
| 1.3.6.1.2.1.10.133.1.8.2.1.7 | ColumnoptIfODUkTtpDEGThr | read-write | current | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored b… |
| 1.3.6.1.2.1.10.133.1.8.2.1.8 | ColumnoptIfODUkTtpDEGM | read-write | current | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkDEGM consecutive bad PM Seconds are detected.… |
| 1.3.6.1.2.1.10.133.1.8.2.1.9 | ColumnoptIfODUkTtpCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the valu… |
| 1.3.6.1.2.1.10.133.1.8.3 | TableoptIfODUkPositionSeqTable | not-accessible | current | A table of ODUk Position Sequence information. |
| 1.3.6.1.2.1.10.133.1.8.3.1 | RowoptIfODUkPositionSeqEntry | not-accessible | current | A conceptual row that contains ODUk position sequence information of an ODUk interface. The ODUk interface is identified by the ifIndex. Associated with each O… |
| 1.3.6.1.2.1.10.133.1.8.3.1.1 | ColumnoptIfODUkPositionSeqIndex | not-accessible | current | This variable identifies a row in the optIfODUkPositionSeqTable Table. Each row of the optIfODUkPositionSeqTable Table represents a TCM or GCC12 access functio… |
| 1.3.6.1.2.1.10.133.1.8.3.1.2 | ColumnoptIfODUkPositionSeqPosition | read-only | current | This variable indicates the position of the TCM or GCC12 access function within the sequence of TCMs & GCC12 access functions of the associated ODUk interface.… |
| 1.3.6.1.2.1.10.133.1.8.3.1.3 | ColumnoptIfODUkPositionSeqPointer | read-only | current | This variable identifies the TCM or GCC12 access function by pointing to the corresponding optIfODUkT or optIfGCC12 entity. |
| 1.3.6.1.2.1.10.133.1.8.4 | TableoptIfODUkNimConfigTable | not-accessible | current | A table of ODUkNim configuration information. |
| 1.3.6.1.2.1.10.133.1.8.4.1 | RowoptIfODUkNimConfigEntry | not-accessible | current | A conceptual row that contains ODUkNim configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry for whic… |
| 1.3.6.1.2.1.10.133.1.8.4.1.1 | ColumnoptIfODUkNimDirectionality | not-accessible | current | Specifies the monitor point for the ODUk Path non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of optIfODUkD… |
| 1.3.6.1.2.1.10.133.1.8.4.1.2 | ColumnoptIfODUkNimDAPIExpected | read-create | current | The DAPI expected by the receiver. This object has no effect if optIfODUkNimTIMDetMode has the value off(1) or sapi(3). |
| 1.3.6.1.2.1.10.133.1.8.4.1.3 | ColumnoptIfODUkNimSAPIExpected | read-create | current | The SAPI expected by the receiver. This object has no effect if optIfODUkNimTIMDetMode has the value off(1) or dapi(2). |
| 1.3.6.1.2.1.10.133.1.8.4.1.4 | ColumnoptIfODUkNimTraceIdentifierAccepted | read-only | current | The actual trace identifier accepted. The value of this object is unspecified if optIfODUkNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(… |
| 1.3.6.1.2.1.10.133.1.8.4.1.5 | ColumnoptIfODUkNimTIMDetMode | read-create | current | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. |
| 1.3.6.1.2.1.10.133.1.8.4.1.6 | ColumnoptIfODUkNimTIMActEnabled | read-create | current | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. |
| 1.3.6.1.2.1.10.133.1.8.4.1.7 | ColumnoptIfODUkNimDEGThr | read-create | current | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored b… |
| 1.3.6.1.2.1.10.133.1.8.4.1.8 | ColumnoptIfODUkNimDEGM | read-create | current | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkNimDEGM consecutive bad PM Seconds are detect… |
| 1.3.6.1.2.1.10.133.1.8.4.1.9 | ColumnoptIfODUkNimCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. The value of this object is unspecified if optIfODUkNimRowStatus has any value other than active(1). |
| 1.3.6.1.2.1.10.133.1.8.4.1.10 | ColumnoptIfODUkNimRowStatus | read-create | current | This columnar object is used for creating and deleting a conceptual row of the optIfODUkNim config table. It is used to model the activateNim and deactivateNim… |
| 1.3.6.1.2.1.10.133.1.8.5 | TableoptIfGCC12ConfigTable | not-accessible | current | A table of GCC12 configuration information. The GCC function processes the GCC overhead bytes passing through them but leave the remainder of the ODUk overhead… |
| 1.3.6.1.2.1.10.133.1.8.5.1 | RowoptIfGCC12ConfigEntry | not-accessible | current | A conceptual row that contains GCC12 configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry. Separate … |
| 1.3.6.1.2.1.10.133.1.8.5.1.1 | ColumnoptIfGCC12Codirectional | not-accessible | current | Indicates the directionality of the GCC12 termination with respect to the associated ODUk CTP. The value true(1) means that the sink part of the GCC12 extracts… |
| 1.3.6.1.2.1.10.133.1.8.5.1.2 | ColumnoptIfGCC12GCCAccess | not-accessible | current | Indicates the GCC access represented by the entity. |
| 1.3.6.1.2.1.10.133.1.8.5.1.3 | ColumnoptIfGCC12GCCPassThrough | read-create | current | Controls whether the selected GCC overhead bytes are passed through or modified. The value true(1) means that the selected GCC overhead bytes are passed throug… |
| 1.3.6.1.2.1.10.133.1.8.5.1.4 | ColumnoptIfGCC12Application | read-create | current | Indicates the application transported by the GCC12 entity. Example applications are ECC, User data channel. The value of this object may not be changed when op… |
| 1.3.6.1.2.1.10.133.1.8.5.1.5 | ColumnoptIfGCC12RowStatus | read-create | current | This columnar object is used for creating and deleting a conceptual row of the optIfGCC12 config table. It is used to model the addGCC12Access and removeGCC12A… |
| 1.3.6.1.2.1.10.133.1.9 | NodeoptIfODUkT | |||
| 1.3.6.1.2.1.10.133.1.9.1 | TableoptIfODUkTConfigTable | not-accessible | current | A table of ODUkT configuration information. |
| 1.3.6.1.2.1.10.133.1.9.1.1 | RowoptIfODUkTConfigEntry | not-accessible | current | A conceptual row that contains ODUkT configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry. Rows in t… |
| 1.3.6.1.2.1.10.133.1.9.1.1.1 | ColumnoptIfODUkTTcmField | not-accessible | current | Indicates the tandem connection monitoring field of the ODUk OH. Valid values are integers from 1 to 6. |
| 1.3.6.1.2.1.10.133.1.9.1.1.2 | ColumnoptIfODUkTCodirectional | not-accessible | current | Indicates the directionality of the ODUkT termination point with respect to the associated ODUk CTP. The value true(1) means that the sink part of the ODUkT TP… |
| 1.3.6.1.2.1.10.133.1.9.1.1.3 | ColumnoptIfODUkTTraceIdentifierTransmitted | read-create | current | The trace identifier transmitted. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (… |
| 1.3.6.1.2.1.10.133.1.9.1.1.4 | ColumnoptIfODUkTDAPIExpected | read-create | current | The DAPI expected by the receiver. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or … |
| 1.3.6.1.2.1.10.133.1.9.1.1.5 | ColumnoptIfODUkTSAPIExpected | read-create | current | The SAPI expected by the receiver. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or … |
| 1.3.6.1.2.1.10.133.1.9.1.1.6 | ColumnoptIfODUkTTraceIdentifierAccepted | read-only | current | The actual trace identifier accepted. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), … |
| 1.3.6.1.2.1.10.133.1.9.1.1.7 | ColumnoptIfODUkTTIMDetMode | read-create | current | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable only to the following three cases. (i) optIfODUkDirecti… |
| 1.3.6.1.2.1.10.133.1.9.1.1.8 | ColumnoptIfODUkTTIMActEnabled | read-create | current | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable only to the following three cases. (i) o… |
| 1.3.6.1.2.1.10.133.1.9.1.1.9 | ColumnoptIfODUkTDEGThr | read-create | current | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored b… |
| 1.3.6.1.2.1.10.133.1.9.1.1.10 | ColumnoptIfODUkTDEGM | read-create | current | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM consecutive bad PM Seconds are detected… |
| 1.3.6.1.2.1.10.133.1.9.1.1.11 | ColumnoptIfODUkTSinkMode | read-create | current | This variable specifies the TCM mode at the entity. The value operational(1) means that TCM Overhead (TCMOH) processes (see ITU-T G.798) shall be performed and… |
| 1.3.6.1.2.1.10.133.1.9.1.1.12 | ColumnoptIfODUkTSinkLockSignalAdminState | read-create | current | Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the ODUKT sink. When a Tandem Connection endpoint is set… |
| 1.3.6.1.2.1.10.133.1.9.1.1.13 | ColumnoptIfODUkTSourceLockSignalAdminState | read-create | current | Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem Connection endpoint is set to … |
| 1.3.6.1.2.1.10.133.1.9.1.1.14 | ColumnoptIfODUkTCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. This object is applicable only when either one of the following three cases holds: (i) optIfODUkDirection… |
| 1.3.6.1.2.1.10.133.1.9.1.1.15 | ColumnoptIfODUkTRowStatus | read-create | current | This columnar object is used for creating and deleting a conceptual row of the optIfODUkT config table. It is used to model the addTCM and removeTCM operations… |
| 1.3.6.1.2.1.10.133.1.9.2 | TableoptIfODUkTNimConfigTable | not-accessible | current | A table of ODUkTNim configuration information. |
| 1.3.6.1.2.1.10.133.1.9.2.1 | RowoptIfODUkTNimConfigEntry | not-accessible | current | A conceptual row that contains ODUkTNim configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry. Rows i… |
| 1.3.6.1.2.1.10.133.1.9.2.1.1 | ColumnoptIfODUkTNimTcmField | not-accessible | current | Indicates the tandem connection monitoring field of the ODUk OH on which non-intrusive monitoring is performed. Valid values are integers from 1 to 6. |
| 1.3.6.1.2.1.10.133.1.9.2.1.2 | ColumnoptIfODUkTNimDirectionality | not-accessible | current | Specifies the monitor point for the ODUk TCM non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of optIfODUkDi… |
| 1.3.6.1.2.1.10.133.1.9.2.1.3 | ColumnoptIfODUkTNimDAPIExpected | read-create | current | The DAPI expected by the receiver. This object has no effect if optIfODUkTNimTIMDetMode has the value off(1) or sapi(3). |
| 1.3.6.1.2.1.10.133.1.9.2.1.4 | ColumnoptIfODUkTNimSAPIExpected | read-create | current | The SAPI expected by the receiver. This object has no effect if optIfODUkTNimTIMDetMode has the value off(1) or dapi(2). |
| 1.3.6.1.2.1.10.133.1.9.2.1.5 | ColumnoptIfODUkTNimTraceIdentifierAccepted | read-only | current | The actual trace identifier accepted. The value of this object is unspecified if optIfODUkTNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf… |
| 1.3.6.1.2.1.10.133.1.9.2.1.6 | ColumnoptIfODUkTNimTIMDetMode | read-create | current | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. |
| 1.3.6.1.2.1.10.133.1.9.2.1.7 | ColumnoptIfODUkTNimTIMActEnabled | read-create | current | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. |
| 1.3.6.1.2.1.10.133.1.9.2.1.8 | ColumnoptIfODUkTNimDEGThr | read-create | current | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored b… |
| 1.3.6.1.2.1.10.133.1.9.2.1.9 | ColumnoptIfODUkTNimDEGM | read-create | current | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM consecutive bad PM Seconds are detec… |
| 1.3.6.1.2.1.10.133.1.9.2.1.10 | ColumnoptIfODUkTNimCurrentStatus | read-only | current | Indicates the defect condition of the entity, if any. The value of this object is unspecified if optIfODUkTNimRowStatus has any value other than active(1). |
| 1.3.6.1.2.1.10.133.1.9.2.1.11 | ColumnoptIfODUkTNimRowStatus | read-create | current | This columnar object is used for creating and deleting a conceptual row of the optIfODUkTNim config table. It is used to model the addTCM and removeTCM operati… |
| 1.3.6.1.2.1.10.133.2 | NodeoptIfConfs | |||
| 1.3.6.1.2.1.10.133.2.1 | NodeoptIfGroups | |||
| 1.3.6.1.2.1.10.133.2.1.1 | GroupoptIfOTMnGroup | current | A collection of OTMn structure information objects. | |
| 1.3.6.1.2.1.10.133.2.1.2 | GroupoptIfPerfMonGroup | current | A collection of performance monitoring interval objects. | |
| 1.3.6.1.2.1.10.133.2.1.3 | GroupoptIfOTSnCommonGroup | current | A collection of configuration objects applicable to all OTSn interfaces. | |
| 1.3.6.1.2.1.10.133.2.1.4 | GroupoptIfOTSnSourceGroupFull | current | A collection of configuration objects applicable to full-functionality/IaDI OTSn interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.5 | GroupoptIfOTSnAPRStatusGroup | current | A collection of objects applicable to OTSn interfaces that support Automatic Power Reduction functions. | |
| 1.3.6.1.2.1.10.133.2.1.6 | GroupoptIfOTSnAPRControlGroup | current | A collection of objects applicable to OTSn interfaces that provide Automatic Power Reduction control functions. | |
| 1.3.6.1.2.1.10.133.2.1.7 | GroupoptIfOTSnSinkGroupBasic | current | A collection of configuration objects applicable to all OTSn interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.8 | GroupoptIfOTSnSinkGroupFull | current | A collection of configuration objects applicable to full-functionality/IaDI OTSn interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.9 | GroupoptIfOTSnSinkPreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OTSn interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.10 | GroupoptIfOTSnSinkPreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OTSn interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.11 | GroupoptIfOTSnSourcePreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OTSn interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.12 | GroupoptIfOTSnSourcePreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OTSn interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.13 | GroupoptIfOMSnCommonGroup | current | A collection of configuration objects applicable to all OMSn interfaces. | |
| 1.3.6.1.2.1.10.133.2.1.14 | GroupoptIfOMSnSinkGroupBasic | current | A collection of configuration objects applicable to all OMSn interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.15 | GroupoptIfOMSnSinkPreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OMSn interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.16 | GroupoptIfOMSnSinkPreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OMSn interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.17 | GroupoptIfOMSnSourcePreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OMSn interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.18 | GroupoptIfOMSnSourcePreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OMSn interfaces that that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.19 | GroupoptIfOChGroupCommonGroup | current | A collection of configuration objects applicable to all OChGroup interfaces. | |
| 1.3.6.1.2.1.10.133.2.1.20 | GroupoptIfOChGroupSinkPreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OChGroup interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.21 | GroupoptIfOChGroupSinkPreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OChGroup interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.22 | GroupoptIfOChGroupSourcePreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OChGroup interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.23 | GroupoptIfOChGroupSourcePreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OChGroup interfaces that that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.24 | GroupoptIfOChCommonGroup | current | A collection of configuration objects applicable to all OCh interfaces. | |
| 1.3.6.1.2.1.10.133.2.1.25 | GroupoptIfOChSinkGroupBasic | current | A collection of configuration objects applicable to all OCh interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.26 | GroupoptIfOChSinkPreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OCh interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.27 | GroupoptIfOChSinkPreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OCh interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.28 | GroupoptIfOChSourcePreOtnPMGroup | current | A collection of pre-OTN performance monitoring objects applicable to OCh interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.29 | GroupoptIfOChSourcePreOtnPMThresholdGroup | current | A collection of pre-OTN performance monitoring threshold objects applicable to OCh interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.30 | GroupoptIfOTUkCommonGroup | current | A collection of configuration objects applicable to all OTUk interfaces. | |
| 1.3.6.1.2.1.10.133.2.1.31 | GroupoptIfOTUkSourceGroup | current | A collection of configuration objects applicable to OTUk interfaces that support source functions. | |
| 1.3.6.1.2.1.10.133.2.1.32 | GroupoptIfOTUkSinkGroup | current | A collection of configuration objects applicable to OTUk interfaces that support sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.33 | GroupoptIfGCC0Group | current | A collection of GCC0 configuration objects. | |
| 1.3.6.1.2.1.10.133.2.1.34 | GroupoptIfODUkGroup | current | A collection of configuration objects applicable to all ODUk interfaces. | |
| 1.3.6.1.2.1.10.133.2.1.35 | GroupoptIfODUkTtpSourceGroup | current | A collection of configuration objects applicable to all interfaces that support ODUk trail termination source functions. | |
| 1.3.6.1.2.1.10.133.2.1.36 | GroupoptIfODUkTtpSinkGroup | current | A collection of ODUk configuration objects applicable to all interfaces that support ODUk trail termination sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.37 | GroupoptIfODUkNimGroup | current | A collection of ODUk Nim configuration objects. | |
| 1.3.6.1.2.1.10.133.2.1.38 | GroupoptIfGCC12Group | current | A collection of GCC12 configuration objects. | |
| 1.3.6.1.2.1.10.133.2.1.39 | GroupoptIfODUkTCommonGroup | current | A collection of configuration objects applicable to all ODUkT instances. | |
| 1.3.6.1.2.1.10.133.2.1.40 | GroupoptIfODUkTSourceGroup | current | A collection of configuration objects applicable to all ODUkT instances that provide source functions. | |
| 1.3.6.1.2.1.10.133.2.1.41 | GroupoptIfODUkTSinkGroup | current | A collection of configuration objects applicable to all ODUkT instances that provide sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.42 | GroupoptIfODUkTSinkGroupCtp | current | A collection of configuration objects applicable to ODUkT instances not colocated with an ODUk TTP that provide sink functions. | |
| 1.3.6.1.2.1.10.133.2.1.43 | GroupoptIfODUkTNimGroup | current | A collection of ODUkT Nim configuration objects. | |
| 1.3.6.1.2.1.10.133.2.2 | NodeoptIfCompl |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| OptIfAcTI | OCTET STRING (SIZE(64)) | current | The trace identifier (TI) accepted at the receiver. |
| OptIfBitRateK | Integer32 | current | Indicates the index 'k' that is used to represent a supported bit rate and the different versions of OPUk, ODUk and OTUk. Allowed values of k are defined in ITU-T G.709. Currently allowed values in G.709 are: k=1 repres… |
| OptIfDEGM | Unsigned32 (2..10) | current | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if OptIfDEGM consecutive bad PM Seconds are detected. |
| OptIfDEGThr | Unsigned32 (1..100) | current | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to OptIfDEGThr. |
| OptIfDirectionality | INTEGER { sink(1), source(2), bidirectional(3) } | current | Indicates the directionality of an entity. |
| OptIfExDAPI | OCTET STRING (SIZE(16)) | current | The Destination Access Point Identifier (DAPI) expected by the receiver. |
| OptIfExSAPI | OCTET STRING (SIZE(16)) | current | The Source Access Point Identifier (SAPI) expected by the receiver. |
| OptIfIntervalNumber | Unsigned32 (1..96) | current | Uniquely identifies a 15-minute interval. The interval identified by 1 is the most recently completed interval, and the interval identified by n is the interval immediately preceding the one identified by n-1. |
| OptIfSinkOrSource | INTEGER { sink(1), source(2) } | current | Indicates the directionality of an entity that is allowed only to be a source or sink. |
| OptIfTIMDetMode | INTEGER { off(1), dapi(2), sapi(3), both(4) } | current | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. |
| OptIfTxTI | OCTET STRING (SIZE(64)) | current | The trace identifier (TI) transmitted. |