MIB for the PacketFlux Standby Power Controller
Imported Objects
PACKETFLUX-SMIpacketfluxMgmt
SNMPv2-CONFOBJECT-GROUP
SNMPv2-SMIGauge32 Integer32 MODULE-IDENTITY OBJECT-TYPE TimeTicks
SNMPv2-TCTruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.32050.2.2IdentitystandbypowerMIB for the PacketFlux Standby Power Controller
1.3.6.1.4.1.32050.2.2.1Scalarpowercontrollerstateread-onlycurrentThe status of the standby power controller.
1.3.6.1.4.1.32050.2.2.2Scalartransferswitchstateread-onlycurrentThe current state in the transfer sequence.
1.3.6.1.4.1.32050.2.2.3Scalarstandbypowerstateread-onlycurrentThe current state in the standby power sequence.
1.3.6.1.4.1.32050.2.2.4Scalarac1voltageread-onlycurrentThe voltage of the AC input AC1 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.5Scalarac1frequencyread-onlycurrentThe frequency of the AC input AC1 in 1/100ths of a Hertz.
1.3.6.1.4.1.32050.2.2.6Scalarac2voltageread-onlycurrentThe voltage of the AC input AC2 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.7Scalarac2frequencyread-onlycurrentThe frequency of the AC input AC2 in 1/100ths of a Hertz.
1.3.6.1.4.1.32050.2.2.8Scalarmtr1voltageread-onlycurrentThe voltage of the DC input Mtr1 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.9Scalarmtr2voltageread-onlycurrentThe voltage of the DC input Mtr2 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.10Scalarpwr1voltageread-onlycurrentThe voltage of the DC input Pwr3 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.11Scalarpwr2voltageread-onlycurrentThe voltage of the DC input Pwr2 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.12Scalarshuntvoltageread-onlycurrentThe voltage of the DC input Shunt in 1/10ths of a millivolt. Can be negative.
1.3.6.1.4.1.32050.2.2.13Scalartemperatureread-onlycurrentThe temperature of the onboard temperature sensor in 1/10ths of a degree centigrade.
1.3.6.1.4.1.32050.2.2.14Scalarrecentunsuccessfulstartsread-writecurrentThe number of times the standby power source was not successfully started. This counter resets upon a successful start. It can also be reset via the web interf…
1.3.6.1.4.1.32050.2.2.15Scalartotalunsuccessfulstartsread-writecurrentThe number of times the standby power source was not successfully started. This counter DOES NOT reset upon a successful start. It can be reset via the web int…
1.3.6.1.4.1.32050.2.2.16Scalarrecentstallsread-writecurrentThe number of times the standby power source has stalled. This counter resets upon a clean shutdown. It can also be reset via the web interface or by writing 0…
1.3.6.1.4.1.32050.2.2.17Scalartotalstallsread-writecurrentThe number of times the standby power source has stalled. This counter DOES NOT reset upon a clean shutdown. It can be reset via the web interface or by writin…
1.3.6.1.4.1.32050.2.2.18Scalarnumberofstartsread-writecurrentThe number of times the secondary power source has started. This counter increments when the standby sequence reaches the running state. This counter can be re…
1.3.6.1.4.1.32050.2.2.19Scalarnumberoftransfersread-writecurrentThe number of times the power has transfered from primary to standby, or back. A complete transfer cycle from primary to standby and back to primary will incre…
1.3.6.1.4.1.32050.2.2.20Scalarcurrenttimeonprimaryread-writecurrentThe amount of time the transfer switch has been in the primary state (position) since the most recent transfer to that state. This timer resets to zero when th…
1.3.6.1.4.1.32050.2.2.21Scalartotaltimeonprimaryread-writecurrentThe amount of time the transfer switch has been in the primary state (position) since power on or the last reset of this counter. This timer does not automatic…
1.3.6.1.4.1.32050.2.2.22Scalarcurrenttimeonstandbyread-writecurrentThe amount of time the transfer switch has been in the standby state (position) since the most recent transfer to that state. This timer resets to zero when th…
1.3.6.1.4.1.32050.2.2.23Scalartotaltimeonstandbyread-writecurrentThe amount of time the transfer switch has been in the standby state (position) since power on or the last reset of this counter. This timer does not automatic…
1.3.6.1.4.1.32050.2.2.24Scalarcurrentstandbyruntimeread-writecurrentThe amount of time the standby power source has been running during it's current run. This timer resets to zero when the standby power source shuts down. This …
1.3.6.1.4.1.32050.2.2.25Scalartotalstandbyruntimeread-writecurrentThe amount of time the standby power source has been running since power on or the last reset of this counter. This timer does not automatically reset. This ti…
1.3.6.1.4.1.32050.2.2.26Scalarlaststandbyrunread-writecurrentThe amount of time since the standby power source ran last. This timer resets upon start of the standby power source and starts timing upon shutdown of the sta…
1.3.6.1.4.1.32050.2.2.27Scalarlaststandbygracefulstopread-writecurrentThe amount of time since standby power source was gracefully shutdown. This timer resets and starts timing upon graceful shutdown of the standby power source. …
1.3.6.1.4.1.32050.2.2.28Scalarlaststandbyunsuccessfulstartread-writecurrentThe amount of time since the last failed start of the standby power source . This timer resets and starts timing upon a unsuccessful start of the power source.…
1.3.6.1.4.1.32050.2.2.29Scalarlaststandbyfailureread-writecurrentThe amount of time since the stall or failure while running of the standby power source . This timer resets and starts timing upon a stall/failure of the power…
1.3.6.1.4.1.32050.2.2.30Scalarswitch1closedread-onlycurrentTrue(1) if the Switch 1 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.31Scalarswitch2closedread-onlycurrentTrue(1) if the Switch 2 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.32Scalarswitch3closedread-onlycurrentTrue(1) if the Switch 3 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.33Scalarswitch4closedread-onlycurrentTrue(1) if the Switch 4 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.34Scalarswitch5closedread-onlycurrentTrue(1) if the Switch 5 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.35Scalarenabledread-onlycurrentTrue(1) if the enable input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.36Scalarrelay1onread-onlycurrentTrue(1) if the Relay 1 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.37Scalarrelay2onread-onlycurrentTrue(1) if the Relay 2 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.38Scalarrelay3onread-onlycurrentTrue(1) if the Relay 3 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.39Scalarrelay4onread-onlycurrentTrue(1) if the Relay 4 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.40Scalarrelay5onread-onlycurrentTrue(1) if the Relay 5 output is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.41Scalarrelay6onread-onlycurrentTrue(1) if the Relay 6 output is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.42Scalarrelay7onread-onlycurrentTrue(1) if the Relay 7 output is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.43Scalarruleswitchstandbyread-onlycurrentTrue(1) if the switch to standby rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.44Scalarrulereturnprimaryread-onlycurrentTrue(1) if the return to primary rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.45Scalarrulestandbygoodread-onlycurrentTrue(1) if the standby power good rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.46Scalarrulestopstandbyread-onlycurrentTrue(1) if the stop standby and consider it failed rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.47Scalarruleexercisestandbyread-onlycurrentTrue(1) if the exercise standby without transfer rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.48Scalarwebcontrol1read-writecurrentTrue(1) if the webcontrol 1 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.49Scalarwebcontrol2read-writecurrentTrue(1) if the webcontrol 2 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.50Scalarwebcontrol3read-writecurrentTrue(1) if the webcontrol 3 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.51Scalarwebcontrol4read-writecurrentTrue(1) if the webcontrol 4 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.52Scalarwebcontrol5read-writecurrentTrue(1) if the webcontrol 5 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.53Scalarwebcontrol6read-writecurrentTrue(1) if the webcontrol 6 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.54Scalarwebcontrol7read-writecurrentTrue(1) if the webcontrol 7 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.55Scalarwebcontrol8read-writecurrentTrue(1) if the webcontrol 8 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle …
1.3.6.1.4.1.32050.2.2.256NodestandbypowerConformance
1.3.6.1.4.1.32050.2.2.256.1NodestandbypowerGroups
1.3.6.1.4.1.32050.2.2.256.1.1GrouppacketfluxStandbypowerAllObjectscurrentThis automatically created object group contains all those objects that do not belong to any other OBJECT-GROUP