MIB Viewer

PBI-MGSIGNALCHARACTERISTICS-MIB

50 objects
Description
Imported Objects
PBI-MAIN-MIBmg
RFC1213-MIBDisplayString
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCRowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.1070.3.2IdentitymgSignalCharacteristicsDescription
1.3.6.1.4.1.1070.3.2.1TabletsOutTablenot-accessiblecurrent
1.3.6.1.4.1.1070.3.2.1.1RowtsOutEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.1.1.1ColumnchannelOutputread-writecurrentoutput channel number
1.3.6.1.4.1.1070.3.2.1.1.2ColumnbitRateread-writecurrentTransport stream output size, 3000EC: from 0 to 16Mpbs; 3000MX:from 0 to 100Mpbs; 3000TM: from 0 to 50Mpbs
1.3.6.1.4.1.1070.3.2.1.1.3ColumnpacketSizeread-writecurrentPacket length, option: 188 or 204
1.3.6.1.4.1.1070.3.2.1.1.4ColumntransportStreamIDread-writecurrentThe transport stream ID for this transport stream as read from the PAT, its value range: reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.1.1.5ColumnotiginalNetworkIDread-writecurrentThe original network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468
1.3.6.1.4.1.1070.3.2.1.1.6ColumnnetworkIDread-writecurrentThe network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468
1.3.6.1.4.1.1070.3.2.1.1.7ColumnbitrateThreshosdPercentread-writecurrentts overflow percent value(0 - 100)
1.3.6.1.4.1.1070.3.2.1.1.8ColumnoutValidBitRateread-onlycurrenttransport stream out valid bit rate
1.3.6.1.4.1.1070.3.2.2TablemgPATTablenot-accessiblecurrentPSI/SI information relating to the PAT, reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.2.1RowmgPATEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.2.1.1ColumnchannelInputPATread-writecurrentThe physical input on which this transport stream appears
1.3.6.1.4.1.1070.3.2.2.1.2ColumnpatSectionread-writecurrentThe transport stream Relating to the PAT seciton, reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.3TablemgPMTTablenot-accessiblecurrentPSI/SI information relating to the PMT
1.3.6.1.4.1.1070.3.2.3.1RowmgPMTEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.3.1.1ColumnchannelInputPMTread-writecurrentThe physical input on which this transport stream appears
1.3.6.1.4.1.1070.3.2.3.1.2ColumnpmtProgramNumberread-writecurrentThe PMT program number as read from PMT,reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.3.1.3ColumnpmtPIDread-writecurrentThe PMT PID as read from PMT,reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.3.1.4ColumnpmtSectionread-writecurrentThe transport stream Relating to the PMT seciton, reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.4TablemgNITTablenot-accessiblecurrentPSI/SI information relating to the NIT
1.3.6.1.4.1.1070.3.2.4.1RowmgNITEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.4.1.1ColumnchannelInputNITread-writecurrentThe physical input on which this transport stream appears
1.3.6.1.4.1.1070.3.2.4.1.2ColumnnetworkTyperead-writecurrentThe network type include two types: actual NIT and others NIT, reference DVB 300-468
1.3.6.1.4.1.1070.3.2.4.1.3ColumnnitActualSectionread-writecurrentRelating to the Actual section, its table ID is 0x40 in NIT,reference DVB 300-468
1.3.6.1.4.1.1070.3.2.4.1.4ColumnnitOhtersSectionread-writecurrentRelating to the others section , its table ID is 0x41 in NIT,reference DVB 300-468
1.3.6.1.4.1.1070.3.2.5TablemgSDTTablenot-accessiblecurrentPSI/SI information relating to the SDT, reference DVB 300-468
1.3.6.1.4.1.1070.3.2.5.1RowmgSDTEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.5.1.1ColumnchannelInputSDTread-writecurrentThe physical input on which this transport stream appears
1.3.6.1.4.1.1070.3.2.5.1.2ColumnsdtSectionread-writecurrentThe transport stream relating to SDT seciton, reference DVB 300-468
1.3.6.1.4.1.1070.3.2.6TablemgFilterTablenot-accessiblecurrentDescription
1.3.6.1.4.1.1070.3.2.6.1RowmgFilterEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.6.1.1ColumnchannelInputFilterread-writecurrentThe physical input on which this transport stream appears
1.3.6.1.4.1.1070.3.2.6.1.2ColumnoldPIDread-writecurrentThe old PID will be filtered output
1.3.6.1.4.1.1070.3.2.6.1.3ColumnnewPIDread-writecurrentThe new PID is bulit according to old PID
1.3.6.1.4.1.1070.3.2.6.1.4ColumnoldProgramNumberread-writecurrentThe old program number,they come from PAT and will be filtered output
1.3.6.1.4.1.1070.3.2.6.1.5ColumnnewProgramNumberread-writecurrentThe new program number, they are bulit and will be made a new PAT
1.3.6.1.4.1.1070.3.2.7TablemgCATTablenot-accessiblecurrentPSI/SI information relating to the CAT, reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.7.1RowmgCATEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.7.1.1ColumnchannelInputCATread-writecurrentThe physical input on which this transport stream appears
1.3.6.1.4.1.1070.3.2.7.1.2ColumncatSectionread-writecurrentThe transport stream Relating to the CAT seciton, reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.8NodetsInput
1.3.6.1.4.1.1070.3.2.8.1ScalarchannelInputread-writecurrentchannel number of input
1.3.6.1.4.1.1070.3.2.8.2ScalarstateLockread-writecurrent0xFFFF is lock, other is unlock
1.3.6.1.4.1.1070.3.2.8.3ScalartsIdPreferenceread-writecurrenttransport stream identifier
1.3.6.1.4.1.1070.3.2.9TablemgBATTablenot-accessiblecurrentPSI/SI information relating to the BAT, reference ISO/IEC 13818-1
1.3.6.1.4.1.1070.3.2.9.1RowmgBATEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.1070.3.2.9.1.1ColumnchannelBATread-writecurrentspecify channel of get BAT
1.3.6.1.4.1.1070.3.2.9.1.2ColumnbatSectionread-writecurrentThe transport stream Relating to the BAT seciton, reference ISO/IEC 13818-1