MIB Viewer

PDN-DIAGNOSTICS-MIB

98 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1795.2.24.2.16.1NodediagTestMIBObjects
1.3.6.1.4.1.1795.2.24.2.16.1.1NodediagIfTest
1.3.6.1.4.1.1795.2.24.2.16.1.1.1TableifLoopbackTestTablenot-accessiblemandatoryThis table contains input and results of a packet loopback test. This table is indexed by ifIndex. This is a interface related test. There can be only one test…
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1RowifLoopbackTestEntrynot-accessiblemandatoryAn entry containing objects for test input and result for packet loopback test
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.1ColumnloopbackTestInputNumCyclesread-writemandatoryThis object corresponds the number of cycles the test to be run for. One cycle corresponds to a 15 second interval. The default value for this object is 40.
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.2ColumnloopbackTestResultsPktsSentread-onlymandatoryThis object corresponds to the number of packets sent
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.3ColumnloopbackTestResultsPktsRcvdOKread-onlymandatoryThis object corresponds to the number of packets which were received without any error
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.4ColumnloopbackTestResultsPktsRcvdErrread-onlymandatoryThis object corresponds to the number of packets which were received with errors
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.5ColumnloopbackTestResultsPktsNotRcvdread-onlymandatoryThis object corresponds to the number of packets which were sent but not received
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.6ColumnloopbackTestResultsPktErrorRateread-onlymandatoryReflects the error rate of the loopback test. this string will represent a floating point number of the form [ErrRate][eE][+-][ErrRateBase] where ErrRate and E…
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.7ColumnloopbackTestResultsErrSecsread-onlymandatoryThis object corresponds to the number of errored seconds
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.8ColumnloopbackTestResultsSvrErrSecsread-onlymandatoryThis object corresponds to the number of severely errored seconds
1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.9ColumnloopbackTestResultsElpTimeread-onlymandatoryThis object corresponds to the number of seconds elapsed since the start of the test.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2TableifBERTObjectsTablenot-accessiblemandatoryThis table contains the objects for Bit Error Rate Test. This table is indexed by ifIndex.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1RowifBERTObjectsEntrynot-accessiblemandatoryAn Entry containing objects of BERT.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.1ColumnifBERTTestDurationread-writemandatoryThis object represents the test duration in seconds.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.2ColumnifBERTElapsedTimeread-onlymandatoryThis object represents the elapsed time in seconds.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.3ColumnifBERTDownSyncUPread-onlymandatoryThis object indicates whether Downstream sync is enabled .
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.4ColumnifBERTUpSyncUPread-onlymandatoryThis object indicates whether upstream sync is enabled.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.5ColumnifBERTSegmentsSentread-onlymandatoryThis object represents the number of segments sent during the test
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.6ColumnifBERTDownMBitsRcvdread-onlymandatoryThis represents the number of million bits rcvd downstream.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.7ColumnifBERTUpMBitsRcvdread-onlymandatoryThis represents the number of million bits rcvd upstream.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.8ColumnifBERTDownBitErrDetectedread-onlymandatoryThis represents the number of bit errors detected downstream.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.9ColumnifBERTUpBitErrDetectedread-onlymandatoryThis represents the number of bit errors detected upstream.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.10ColumnifBERTDownBitErrRateread-onlymandatoryThis string will represent a floating point number of the form [Er rRate] [eE] [+-] [ErrRatebase] where ErrTare and errRateBase are integers.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.11ColumnifBERTUpBitErrRateread-onlymandatoryThis object reflects the error rate of BERT in Upstream direction. This string will represent a floating point number of the form [ErrRate] [eE] [+-] [ErrRateb…
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.12ColumnifBERTDownErroredSecsread-onlymandatoryThis represents number of errored seconds downstream. Errored second is a second in which there is at least 1 block error.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.13ColumnifBERTUpErroredSecsread-onlymandatoryThis represents number of errored seconds upstream. Errored second is a second in which there is at least 1 block error.
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.14ColumnifBERTDownLineRateread-onlymandatoryThis represents the downstream line rate in KBPS
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.15ColumnifBERTUpLineRateread-onlymandatoryThis represents the Upstream line rate in KBPS
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.16ColumnifBERTDownMarginread-onlymandatoryThis represents the Downstream margin in decibels (DB).
1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.17ColumnifBERTUpMarginread-onlymandatoryThis represents the upstream margin in decibels (DB).
1.3.6.1.4.1.1795.2.24.2.16.1.1.3TableifBLERTObjectsTablenot-accessiblemandatoryThis table contains the objects for Block Error Rate Test (BLERT). This table is indexed by ifIndex.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1RowifBLERTObjectsEntrynot-accessiblemandatoryAn Entry containing objects of BLERT.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.1ColumnifBLERTTestDurationread-writemandatoryThis object represents the test duration in seconds.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.2ColumnifBLERTElapsedTimeread-onlymandatoryThis object represents the elapsed time in seconds since the test started.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.3ColumnifBLERTTxSeqCountread-onlymandatoryThis object indicates the next Tx sequence.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.4ColumnifBLERTRxSeqCountread-onlymandatoryThis object indicates the next Rx sequence.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.5ColumnifBLERTRxGoodFramesread-onlymandatoryThis object indicates the number of good frames received.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.6ColumnifBLERTTxGoodFramesread-onlymandatoryThis object indicates the number of good frames transmitted.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.7ColumnifBLERTRxBadFramesread-onlymandatoryThis object indicates the number of bad frames received.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.8ColumnifBLERTTxBadFramesread-onlymandatoryThis object indicates the number of bad frames transmitted.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.9ColumnifBLERTDnLineRateread-onlymandatoryThis object indicates the downstream line rate.
1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.10ColumnifBLERTUpLineRateread-onlymandatoryThis object indicates the upstream line rate.
1.3.6.1.4.1.1795.2.24.2.16.1.2NodediagApplTest
1.3.6.1.4.1.1795.2.24.2.16.1.2.1ScalarapplMaxNumberOfTestsread-onlymandatoryThis object identifies the maximum number of application based tests that can be simultaneously instantiated on the device.
1.3.6.1.4.1.1795.2.24.2.16.1.2.2ScalarapplCurrentNumberOfTestsread-onlymandatoryThis object identifies the current number of application based tests that are running on the device.
1.3.6.1.4.1.1795.2.24.2.16.1.2.3ScalarapplStopAllTestsread-writemandatoryThe value of this object corresponds to stop all application based tests on the device. noOp stop but current test results are still available stopAndClear and…
1.3.6.1.4.1.1795.2.24.2.16.1.2.4ScalarapplNewTestIdread-onlymandatoryThis value of this object corresponds to getting a magic number to start an application based test. The magic number is used as an index to create a row for th…
1.3.6.1.4.1.1795.2.24.2.16.1.2.5TableapplTestStatusTablenot-accessiblemandatoryThis table controls all the application tests. It defines a test type, starts a test, and clears a test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1RowapplTestStatusEntrynot-accessiblemandatoryAn entry containing objects for invoking application based tests
1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.1ColumnapplTestIdread-onlymandatoryA unique ID to identify each application test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.2ColumnapplTestTyperead-writemandatoryThis object defines the application test type.
1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.3ColumnapplTestStatusread-onlymandatoryThis object shows the current status of an application test. none - indicates waiting for test parameters. inProgress - indicates the test is in process. succe…
1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.4ColumnapplTestErrorCoderead-onlymandatoryThis object shows the reason for a test failure.
1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.5ColumnapplTestOwnerread-writemandatoryThe network manager who has started the test
1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.6ColumnapplTestRowStatusread-writemandatoryThis object is used to create a new row or delete an existing row for an application test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6TableapplPingTestTablenot-accessiblemandatoryThis table contains objects which allow network manager to ping a destination.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1RowapplPingTestEntrynot-accessiblemandatoryThis table contains the input parameters for a ping test and the results of the ping test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.1ColumnapplPingTestIdread-onlymandatoryA unique ID to identify each application test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.2ColumnapplPingTestIpAddressread-writemandatoryThe IP address to be pinged.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.3ColumnapplPingTestSourceIpAddrread-writemandatoryThe Source IP address where we are pinging from. This is an optional object for some devices. See operational specification for its use.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.4ColumnapplPingTestPacketSizeread-writemandatoryThis object corresponds to the size of the packet (in bytes) which will be sent during the Ping test. The default value for this object is 64 bytes
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.5ColumnapplPingTestTimeoutread-writemandatoryThis object corresponds to a timeout value (in seconds) between Pings. The default value for this object is 5 seconds
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.6ColumnapplPingTestMaxPingsread-writemandatoryThis object corresponds to the maximum number of times the device should Ping for the destination. The default value for this object is 10
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.7ColumnapplPingTestPktsSentread-onlymandatoryThis object corresponds to the total number of packets sent.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.8ColumnapplPingTestPktsRecvread-onlymandatoryThis object corresponds to the total number of packets received without error
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.9ColumnapplPingTestMinTimeread-onlymandatoryThe minimum round trip time.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.10ColumnapplPingTestMaxTimeread-onlymandatoryThe maximum round trip time.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.11ColumnapplPingTestAvgTimeread-onlymandatoryThe average round trip time.
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.12ColumnapplPingTestDomainread-writemandatoryThis object specifies the destination ip address's domain. The Default is service domain. Not allowed if source ip address is entered. This is an optional obje…
1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.13ColumnapplPingTestIfIndexread-writemandatoryThis object specifies the interface over which the ping test will take place.
1.3.6.1.4.1.1795.2.24.2.16.1.2.7TableapplTracerouteConfigTablenot-accessiblemandatoryThis table contains objects which allow network manager to enter the parameters of a traceroute test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1RowapplTracerouteConfigEntrynot-accessiblemandatoryThis table contains the input parameters for a traceroute test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.1ColumnapplTracerouteTestIdread-onlymandatoryA unique ID to identify each application test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.2ColumnapplTracerouteIpAddressread-writemandatoryThe destination IP address of a traceroute test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.3ColumnapplTracerouteSourceIpAddrread-writemandatoryThe source IP address of where the traceroute test started. This is an optional object for some devices. See operational specification for its use.
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.4ColumnapplTraceroutePktsSizeread-writemandatoryThis object corresponds to the size of the packet (in bytes) which will be sent during the traceroute test. Please refer to product specific documentation for …
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.5ColumnapplTracerouteTimeoutread-writemandatoryThis object corresponds to a timeout value (in seconds) of a traceroute test. The default value for this object is 5 seconds
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.6ColumnapplTracerouteMaxHopsread-writemandatoryThis object corresponds to the maximum number of hops to reach the destination. The default value for this object is device specific. See Operational Specifica…
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.7ColumnapplTracerouteDomainread-writemandatoryThis object specifies the destination ip address's domain. The Default is service domain. Not allowed if source ip address is entered. This is an optional obje…
1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.8ColumnapplTracerouteIfIndexread-writemandatoryThis object specifies the interface over which the trace-route test will take place.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8TableapplTracerouteResultTablenot-accessiblemandatoryThis table contains results of traceroute test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1RowapplTracerouteResultEntrynot-accessiblemandatoryAn entry contains the objects for the traceroute test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.1ColumnapplTracerouteResultTestIdread-onlymandatoryA unique ID to identify each application test.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.2ColumnapplTracerouteHopCountread-onlymandatoryThis object contains the number of hops to reach the gateway.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.3ColumnapplTracerouteIpAddrread-onlymandatoryThis object contains the IP address of the gateway.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.4ColumnapplTraceroutePktSizeread-onlymandatoryThis object corresponds to the size of the packet (in bytes) which will be sent during the traceroute test. Please refer to product specific documentation for …
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.5ColumnapplTracerouteProbe1RTTread-onlymandatoryThis object contains the round trip time (rtt) of the first probe sent to the gateway. If the probe has a timeout the rtt is set to -1.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.6ColumnapplTracerouteProbe2RTTread-onlymandatoryThis object contains the round trip time (rtt) of the second probe sent to the gateway. If the probe has a timeout the rtt is set to -1.
1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.7ColumnapplTracerouteProbe3RTTread-onlymandatoryThis object contains the round trip time (rtt) of the third probe sent to the gateway. If the probe has a timeout the rtt is set to -1.
1.3.6.1.4.1.1795.2.24.2.16.1.3NodediagTest
1.3.6.1.4.1.1795.2.24.2.16.1.3.1ScalardiagTestTrapEnableread-writemandatoryThis object is used to disable or enable TestOver and TestStart trap for all tests. It is bit sum and possible bit positions are 1 TestStart trap 2 TestOver tr…
1.3.6.1.4.1.1795.2.24.2.16.2NodediagTestMIBTraps
1.3.6.1.4.1.1795.2.24.2.16.2.1NodediagApplTestStartThis trap signifies that an application test has been initiated.
1.3.6.1.4.1.1795.2.24.2.16.2.2NodediagIfTestStartThis trap signifies that a diagnostic test has been initiated.
1.3.6.1.4.1.1795.2.24.2.16.2.101NodediagApplTestStopThis trap signifies that an application test has completed. This trap compliments the diagApplTestStart trap.
1.3.6.1.4.1.1795.2.24.2.16.2.102NodediagIfTestOverThis trap signifies that a diagnostic test has completed. This trap compliments the diagIfTestStart trap