1.3.6.1.4.1.1795.2.24.2.6.5Nodeent-ds1
1.3.6.1.4.1.1795.2.24.2.6.5.1NodedevDS1Test
1.3.6.1.4.1.1795.2.24.2.6.5.1.1TabledevDS1TestTablenot-accessiblemandatoryThe Paradyne DS1 Interface Test Table.
1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1RowdevDS1TestEntrynot-accessiblemandatoryAn entry in the Paradyne DS1 Interface Test Table.
1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.1ColumndevDS1TestIfIndexread-onlymandatoryThe index value which uniquely identifies the interface for which this entry contains information on interface tests. The interface identified by a particular …
1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.2ColumndevDS1TestTyperead-onlymandatoryThe index value which uniquely identifies the test for which this entry contains information.
1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.3ColumndevDS1TestControlread-writemandatoryA control variable used to start and stop operator- initiated interface tests. Writing idle(1) to the test table entry terminates the specified test for the in…
1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.4ColumndevDS1TestArgumentread-writemandatoryAny argument required by the test being executed.
1.3.6.1.4.1.1795.2.24.2.6.5.1.2TabledevDS1MonResultTablenot-accessiblemandatoryThe Paradyne Device Monitor Test Pattern Result Table.
1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1RowdevDS1MonResultEntrynot-accessiblemandatoryAn entry in the Paradyne Device Monitor Test Pattern Result Table.
1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.1ColumndevDS1MonResultIfIndexread-onlymandatoryThe index value which uniquely identifies the interface for which this entry contains information on the result of the monitor test pattern request. The interf…
1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.2ColumndevDS1MonResultTestTyperead-onlymandatoryThe index value which uniquely identifies the test for which this entry contains information.
1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.3ColumndevDS1MonResultCoderead-onlymandatoryThis object contains a code for more specific information on the test pattern monitoring result. A value of none(1) indicates that no further information is av…
1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.4ColumndevDS1MonResultErrorCountread-writemandatoryThe number of bit errors detected in the received monitoring test pattern. The error count is updated once every second. The error count does not increment dur…
1.3.6.1.4.1.1795.2.24.2.6.5.1.3TabledevDS1SendControlTablenot-accessiblemandatoryThe Paradyne Device Send Test Pattern Control Table.
1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1RowdevDS1SendControlEntrynot-accessiblemandatoryAn entry in the Paradyne Device Send Test Pattern Control Table.
1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.1ColumndevDS1SendControlIfIndexread-onlymandatoryThe index value which uniquely identifies the interface for which this entry contains information on the result of the monitor test pattern request. The interf…
1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.2ColumndevDS1SendControlInjectErrread-writemandatorySetting this object to inject(2) will inject one error in the data pattern being sent. If no pattern is being sent, the agent will return BAD VALUE. Reading th…
1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.3ColumndevDS1SendControlErrorCountread-onlymandatoryThe number of bit errors injected into the test pattern being sent. The maximum value of this object is 99,999.