PDN-FILTER-MIB
109 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1795.2.24.2.23.1 | NodesysDevFilterMIBObjects | |||
| 1.3.6.1.4.1.1795.2.24.2.23.1.1 | NodesysDevFilter | |||
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.1 | ScalarsysDevSNInjectionType | not-accessible | mandatory | The value of this object corresponds to the remote injection type |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.2 | ScalarsysDevSNInjectionVnid | not-accessible | mandatory | This object corresponds to the vnid id (bound to an interface) on which filter injection is not supported or has failed |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3 | TablesysDevFilterConfigTable | not-accessible | mandatory | This table allows the user to configure filtering information. Every filter is comprised of a number of rules(see SysDevRuleTable). When a filter is bound to a… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1 | RowsysDevFilterConfigTableEntry | not-accessible | mandatory | Describes a specific entry of the filter configuration table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.1 | ColumnsysDevFilterIndex | read-only | mandatory | The value of this object is an index of the filter. This object is used by sysDevFilterConfigTable to identify the row in the table. When creating new row of t… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.2 | ColumnsysDevFilterName | read-write | mandatory | The value of this object corresponds directly to the name of the filter. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.3 | ColumnsysDevFilterType | read-write | mandatory | The value of this object corresponds directly to the type of the filter. Ethernet is layer 2 filter, Ip are layer 3 filters (include layer 4 protocol filtering… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.4 | ColumnsysDevDefFilterAction | read-write | mandatory | The value of this object corresponds to the default action taken on a particular IP packet based on the filter rule. forward - the packet is forwarded discard … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.5 | ColumnsysDevFilterNumOfDynamicRules | read-only | mandatory | This object corresponds to the number of dynamic rules configured for this filter. Default is zero. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.6 | ColumnsysDevFilterNumOfStaticRules | read-only | mandatory | This object corresponds to the number of static rules configured for this filter. Default is zero |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.7 | ColumnsysDevFilterRefCount | read-only | mandatory | This object corresponds to the number of references for this filter by the various interfaces of the system For Example if filter 'abc' is bound to two of the … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.3.1.8 | ColumnsysDevFilterRowStatus | read-write | mandatory | The object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4 | TablesysDevL2FilterRuleConfigTable | not-accessible | mandatory | This table allows the user to configure the rules of each IP filter. When a filter is bound to an interface, all the rules of that particular filter apply to t… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1 | RowsysDevL2FilterRuleConfigTableEntry | not-accessible | mandatory | Describes a specific entry of the filter rule configuration table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.1 | ColumnsysDevL2FilterRuleIndex | read-only | mandatory | The value of this object is an index of the filter rule table. This object is used by sysDevFilterConfigTable to identify the row in the table. When creating n… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.2 | ColumnsysDevL2FilterRuleName | read-write | mandatory | The value of this object corresponds directly to the name of the rule. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.3 | ColumnsysDevL2FilterRuleEtherFrameType | read-write | mandatory | This value descirbes if Ethernet frame types defined that can be transmitted. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.4 | ColumnsysDevL2FilterRuleEtherType | read-write | mandatory | This value descirbes if Ethernet types defined in RFC1700 are specified as range or one single type. It is possible to create rule using a range of types and t… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.5 | ColumnsysDevL2FilterRuleEtherTypeRangeStarts | read-write | mandatory | This value corresponds to Ethernet types defined in RFC1700. It is possible to create rule using a range of types and therefore next object is added to create … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.6 | ColumnsysDevL2FilterRuleEtherTypeRangeEnds | read-write | mandatory | This value corresponds to Ethernet types defined in RFC1700. It is possible to create rule using a range of types and therefore this object is added to create … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.7 | ColumnsysDevL2FilterRuleAction | read-write | mandatory | The value of this object specify the action to be done if the rule is matched to a packet. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.4.1.8 | ColumnsysDevL2FilterRuleRowStatus | read-write | mandatory | The object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.5 | TablesysDevFilterBindingTable | not-accessible | mandatory | This table allows us to bind filters to a particular interface. As such this table is indexed by ifIndex, and by sysDevFilterBindingIndex. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.5.1 | RowsysDevFilterBindingTableEntry | not-accessible | mandatory | Describes a specific entry of the filter binding table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.5.1.1 | ColumnsysDevFilterBindingIndex | read-only | mandatory | The value of this object corresponds directly to the filter index from sysDevFilterConfigTable. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.5.1.2 | ColumnsysDevFilterBindingDirection | read-only | mandatory | The value of this object corresponds directly to the type of the filter which needs to be bound to a particular interface. inboundFilter - This indicates that … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.5.1.3 | ColumnsysDevFilterBindingAdminStatus | read-write | mandatory | The value of this is used to configure admin status of filter binding. If admin status is up(1) that means that the binding is active. If the status is down(2)… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.5.1.4 | ColumnsysDevFilterBindingOperStatus | read-write | mandatory | The value of this is used to read oper status of filter binding. If oper status is up(1) that means that the binding is active. If the status is down(2) it mea… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.5.1.5 | ColumnsysDevFilterBindingRowStatus | read-write | mandatory | This object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.6 | ScalarsysDevFilterIndexNext | read-only | mandatory | This object contains an appropriate value to be used for sysDevFilterConfigTable. The value of 0 indicates that no unassigned entries are available. To obtain … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.7 | ScalarsysDevL2FilterRuleIndexNext | read-only | mandatory | This object contains an appropriate value to be used for sysDevL2FilterRuleConfigTable. The value of 0 indicates that no unassigned entries are available. To o… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.8 | TablesysDevFilterToRuleBindingTable | not-accessible | mandatory | This table allows us to bind filters to a particular rules. As such this table is indexed by sysDevFilterToRuleBindingIndex, and by sysDevL2FilterIndex. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.8.1 | RowsysDevFilterToRuleBindingTableEntry | not-accessible | mandatory | Describes a specific entry of the filter binding table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.8.1.1 | ColumnsysDevFilterToRuleBindingIndex | read-only | mandatory | The value of this object corresponds directly to the rule index from sysDevL2FilterRuleTable. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.8.1.2 | ColumnsysDevFilterToRulePriority | read-write | mandatory | Internally the table will be sorted based on this object- in the increasing order of priority. The highest priority being 1. The table cannot be created withou… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.8.1.3 | ColumnsysDevFilterToRuleBindingRowStatus | read-write | mandatory | This object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9 | TablesysDevL3FilterRuleConfigTable | not-accessible | mandatory | This table allows the user to configure the rules for layer three filter. When a filter is bound to an interface, all the rules of that particular filter apply… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1 | RowsysDevL3FilterRuleConfigTableEntry | not-accessible | mandatory | Describes a specific entry of the filter rule configuration table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.1 | ColumnsysDevL3FilterRuleIndex | read-only | mandatory | The value of this object is an index of the filter rule table. This object is used by sysDevFilterConfigTable to identify the row in the table. When creating n… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.2 | ColumnsysDevL3FilterRuleName | read-write | mandatory | The value of this object corresponds directly to the name of the rule. It is highly recommended that the RuleName be unique user friendly name. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.3 | ColumnsysDevL3FilterRuleSrcAddress | read-write | mandatory | The value of this object corresponds directly to a source IP Address. This object could be set if IP packets need to be filtered based on where it is coming fr… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.4 | ColumnsysDevL3FilterRuleSrcAddrMask | read-write | mandatory | The value of this object corresponds directly to an source IP Address Mask. The value of this object is bitwise anded with the source address within the IP pac… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.5 | ColumnsysDevL3FilterRuleSrcAddrAction | read-write | mandatory | This object specifies action taken with the source address filtering. If the selection allows any SrcAddr (effectively ignoring this filed) than 'none' (3) is … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.6 | ColumnsysDevL3FilterRuleSrcPortNum | read-write | mandatory | The UDP or TCP port number of the source on which this filter is applied. This object is used as a start of range if the source comparison type is in-range or … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.7 | ColumnsysDevL3FilterRuleMaxSrcPortNum | read-write | mandatory | The maximum UDP or TCP port number of the source on which this filter is applied. This object is valid only if the source comparison type is in-range or out-ra… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.8 | ColumnsysDevL3FilterRuleSrcCompType | read-write | mandatory | The value of this object corresponds to the type of comparison which is to be made for source based filtering for the particular rule of the filter. none - no … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.9 | ColumnsysDevL3FilterRuleDestAddress | read-write | mandatory | The value of this object corresponds directly to an destination IP Address. This object could be set if IP packets need to be filtered based on where it is goi… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.10 | ColumnsysDevL3FilterRuleDestAddrMask | read-write | mandatory | The value of this object corresponds directly to an destination IP Address Mask. The value of this object is bitwise anded with the destination address within … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.11 | ColumnsysDevL3FilterRuleDestAddrAction | read-write | mandatory | This object specifies action taken for destination address filtering. If the selection allows any DestAddr (effectively ignoring this filed) than 'none' (3) is… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.12 | ColumnsysDevL3FilterRuleDestPortNum | read-write | mandatory | The UDP or TCP port number of the destination on which this filter is applied. This object is used as a start of range if the source comparison type is in-rang… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.13 | ColumnsysDevL3FilterRuleMaxDestPortNum | read-write | mandatory | The maximum UDP or TCP port number of the destination on which this filter is applied. This object is valid only if the destination comparison type is in-range… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.14 | ColumnsysDevL3FilterRuleDestCompType | read-write | mandatory | The value of this object corresponds to the type of comparison which is to be made for destination based filtering for the particular rule of the filter. none … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.15 | ColumnsysDevL3FilterRuleProtocolTypeUdp | read-write | mandatory | The value of this object corresponds to the action taken on a particular UDP packet based on the source/ destination port comparison rule. If the selection all… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.16 | ColumnsysDevL3FilterRuleProtocolTypeTcp | read-write | mandatory | The value of this object corresponds to the action taken on a particular TCP packet bases on the source/ destination port comparison rule. If the selection all… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.17 | ColumnsysDevL3FilterRuleProtocolTypeIcmp | read-write | mandatory | The value of this object corresponds to the action taken on a particular ICMP packet bases on the protocol type comparison rule. If the selection allows any Ic… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.9.1.18 | ColumnsysDevL3FilterRuleRowStatus | read-write | mandatory | The object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.1.10 | ScalarsysDevL3FilterRuleIndexNext | read-only | mandatory | This object contains an appropriate value to be used for sysDevL3FilterRuleConfigTable. The value of 0 indicates that no unassigned entries are available. To o… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2 | NodesysDevIpFilter | |||
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1 | TablesysDevIpFilterConfigTable | not-accessible | mandatory | This table allows the user to configure filtering information. Every filter is comprised of a number of rules(see SysDevRuleTable). When a filter is bound to a… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1 | RowsysDevIpFilterConfigTableEntry | not-accessible | mandatory | Describes a specific entry of the filter configuration table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.1 | ColumnsysDevIpFilterName | read-only | mandatory | The value of this object corresponds directly to the name of the filter. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.2 | ColumnsysDevIpDefFilterAction | read-write | mandatory | The value of this object corresponds to the default action taken on a particular IP packet based on the filter rule. forward - the packet is forwarded discard … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.3 | ColumnsysDevIpFilterNumOfDynamicRules | read-only | mandatory | This object corresponds to the number of dynamic rules configured for this filter |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.4 | ColumnsysDevIpFilterNumOfStaticRules | read-only | mandatory | This object corresponds to the number of static rules configured for this filter |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.5 | ColumnsysDevIpFilterRefCount | read-only | mandatory | This object corresponds to the number of references for this filter by the various interfaces of the system For Example if filter 'abc' is bound to two of the … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.6 | ColumnsysDevIpFilterTcpAckFilterAction | read-write | mandatory | The value of this object corresponds to the default action taken on the first TCP ACK packet of the TCP connection. This object is not supported for MCC. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.7 | ColumnsysDevIpFilterDhcpFilterAction | read-write | mandatory | The value of this object corresponds to the default action taken on the DHCP transaction messages. This object is not supported for mcc. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.1.1.8 | ColumnsysDevIpFilterRowStatus | read-write | mandatory | The object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2 | TablesysDevIpFilterRuleConfigTable | not-accessible | deprecated | This table allows the user to configure the rules of each IP filter. When a filter is bound to an interface, all the rules of that particular filter apply to t… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1 | RowsysDevIpFilterRuleConfigTableEntry | not-accessible | deprecated | Describes a specific entry of the filter rule configuration table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.1 | ColumnsysDevIpRuleFilterName | read-only | deprecated | The value of this object corresponds directly to the name of the filter. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.2 | ColumnsysDevIpFilterRuleNumber | read-only | deprecated | The value of this object corresponds directly to a rule within a particular filter. If the value of this object is 0, then the sets apply to the filter as a wh… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.3 | ColumnsysDevIpFilterRuleSrcAddress | read-write | deprecated | The value of this object corresponds directly to an source IP Address. This object could be set if IP packets need to be filtered based on where it is coming f… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.4 | ColumnsysDevIpFilterRuleSrcAddrMask | read-write | deprecated | The value of this object corresponds directly to an source IP Address Mask. The value of this object is bitwise anded with the source address within the IP pac… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.5 | ColumnsysDevIpFilterRuleSrcAddrCompEnable | read-write | deprecated | This object enables or disables the source address comparison. It is not supported for MCC. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.6 | ColumnsysDevIpFilterRuleSrcPortNum | read-write | deprecated | The UDP or TCP port number of the source on which this filter is applied. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.7 | ColumnsysDevIpFilterRuleMaxSrcPortNum | read-write | deprecated | The maximum UDP or TCP port number of the source on which this filter is applied. This object is valid only if the source comparison type is in-range or out-ra… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.8 | ColumnsysDevIpFilterRuleSrcCompType | read-write | deprecated | The value of this object corresponds to the type of comparison which is to be made for source based filtering for the particular rule of the filter. none - no … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.9 | ColumnsysDevIpFilterRuleDestAddress | read-write | deprecated | The value of this object corresponds directly to an destination IP Address. This object could be set if IP packets need to be filtered based on where it is goi… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.10 | ColumnsysDevIpFilterRuleDestAddrMask | read-write | deprecated | The value of this object corresponds directly to an destination IP Address Mask. The value of this object is bitwise anded with the destination address within … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.11 | ColumnsysDevIpFilterRuleDestAddrCompEnable | read-write | deprecated | This object enables or disables the destination address comparison. It is not supported for MCC. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.12 | ColumnsysDevIpFilterRuleDestPortNum | read-write | deprecated | The UDP or TCP port number of the destination on which this filter is applied |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.13 | ColumnsysDevIpFilterRuleMaxDestPortNum | read-write | deprecated | The maximum UDP or TCP port number of the destination on which this filter is applied. This object is valid only if the destination comparison type is in-range… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.14 | ColumnsysDevIpFilterRuleDestCompType | read-write | deprecated | The value of this object corresponds to the type of comparison which is to be made for destination based filtering for the particular rule of the filter. none … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.15 | ColumnsysDevIpFilterRuleType | read-only | deprecated | The value of this object corresponds to the type of type of rule configured static - This indicates that the rule was configured by an NMS either by SNMP, cons… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.16 | ColumnsysDevIpFilterRuleProtocolTypeUdp | read-write | deprecated | The value of this object corresponds to the action taken on a particular UDP packet based on the source/ destination port comparison rule. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.17 | ColumnsysDevIpFilterRuleProtocolTypeTcp | read-write | deprecated | The value of this object corresponds to the action taken on a particular TCP packet bases on the source/ destination port comparison rule. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.18 | ColumnsysDevIpFilterRuleProtocolTypeIcmp | read-write | deprecated | The value of this object corresponds to the action taken on a particular ICMP packet bases on the protocol type comparison rule. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.2.1.19 | ColumnsysDevIpFilterRuleRowStatus | read-write | deprecated | The object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.3 | ScalarsysDevMaxNumOfInputIpFilters | read-only | mandatory | The value of this object corresponds directly to the max number of input IP filters supported by each device. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.4 | ScalarsysDevMaxNumOfOutputIpFilters | read-only | mandatory | The value of this object corresponds directly to the max number of Output IP filters supported by each device. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.5 | TablesysDevIpFilterBindingTable | not-accessible | mandatory | This table allows us to bind filters to a particular interface. As such this table is doubly indexed by ifIndex and sysDevIpBindingFilterName. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.5.1 | RowsysDevIpFilterBindingTableEntry | not-accessible | mandatory | Describes a specific entry of the filter binding table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.5.1.1 | ColumnsysDevIpBindingFilterName | read-only | mandatory | The value of this object corresponds directly to the name of the filter. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.5.1.2 | ColumnsysDevIpBindingFilterType | read-write | mandatory | The value of this object corresponds directly to the type of the filter which needs to be bound to a particular interface. inputFilter - This indicates that th… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.5.1.3 | ColumnsysDevIpBindingFilterRowStatus | read-write | mandatory | This object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.6 | TablesysDevIpFilterSNBindingTable | not-accessible | mandatory | This table allows us to bind filters to a particular interface on portcards. This table is indexed by ifIndex, sysDevIpSNBindingVnidId and sysDevIpSNBindingFil… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.6.1 | RowsysDevIpFilterSNBindingTableEntry | not-accessible | mandatory | Describes a specific entry of the SNfilter binding table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.6.1.1 | ColumnsysDevIpSNBindingVnidId | read-only | mandatory | The VNID Id number of the virtual network to which this filter is bound. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.6.1.2 | ColumnsysDevIpSNBindingFilterName | read-only | mandatory | The value of this object corresponds directly to the name of the filter. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.6.1.3 | ColumnsysDevIpSNBindingFilterType | read-write | mandatory | The value of this object corresponds directly to the type of the filter which needs to be bound to a particular interface. inputFilter - This indicates that th… |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.6.1.4 | ColumnsysDevIpSNBindingFilterRowStatus | read-write | mandatory | This object is used to add or delete a row from this table. |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.7 | ScalarsysDevIpInputPacketsFiltered | read-only | mandatory | The number of IP packets that have been filtered on all the incoming interfaces due to not matching programmed filter entries on interfaces that are activated … |
| 1.3.6.1.4.1.1795.2.24.2.23.1.2.8 | ScalarsysDevIpOutputPacketsFiltered | read-only | mandatory | The number of IP packets that have been filtered on all the outgoing interfaces due to not matching programmed filter entries on interfaces that are activated … |
| 1.3.6.1.4.1.1795.2.24.2.23.2 | NodesysDevFilterMIBTraps | |||
| 1.3.6.1.4.1.1795.2.24.2.23.2.22 | NodesysDevSNInjectionFailureTrap | This trap signifies that the injection of filters to SN failed It is of warning class | ||
| 1.3.6.1.4.1.1795.2.24.2.23.2.23 | NodesysDevSNInjectionIncompatibleTrap | This trap signifies that the injection of filters is not supported by the SN. It is of warning class |