MIB Viewer

PDN-LINK-FAULT-MGMT-MIB

20 objects
This management information module supports the objects to be used for fault management configuration on primary and secondary links.
Imported Objects
PDN-HEADER-MIBpdnLinkFaultMgmt
RFC1213-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.1795.2.24.2.40.1IdentitypdnLinkFaultMgmtMIBThis management information module supports the objects to be used for fault management configuration on primary and secondary links.
1.3.6.1.4.1.1795.2.24.2.40.1.1NodepdnLinkFaultMgmtMIBObjects
1.3.6.1.4.1.1795.2.24.2.40.1.1.1ScalarpdnLinkFaultMgmtApsSelectionread-writecurrentThis object is used to enable or disable the Automatic Protection Switching (Aps) feature on this device. This object can not be enabled if the -Switchover due…
1.3.6.1.4.1.1795.2.24.2.40.1.1.2ScalarpdnLinkFaultMgmtSwitchoverSelectionread-writecurrentThis object is used to enable or disable the Switchover Due to link failures feature on on this device. This object can not be enabled if the APS feature is en…
1.3.6.1.4.1.1795.2.24.2.40.1.1.3TablepdnLinkFailureConfigTablenot-accessiblecurrentThis table contains one row per link being monitored for link failures.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1RowpdnLinkFailureConfigEntrynot-accessiblecurrentConfiguration information about a particular interface being monitored for link failured.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.1ColumnpdnLinkFailureLOSPeriodBeforeSwitchingread-writecurrentThis object allows users to configure the amount of time a LOS condition shall exist on this uplink before initiating a switchover. Switchover due to LOS condi…
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.2ColumnpdnLinkFailureLOFPeriodBeforeSwitchingread-writecurrentThis object allows users to configure the amount of time a LOF condition shall exist on this uplink before initiating a switchover. Switchover due to LOF condi…
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.3ColumnpdnLinkFailureAISLPeriodBeforeSwitchingread-writecurrentThis object allows users to configure the amount of time a AIS-L condition shall exist on this uplink before initiating a switchover. Switchover due to AIS-L c…
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.4ColumnpdnLinkFailureSdPeriodBeforeSwitchingread-writecurrentThis object allows users to configure the amount of time a Signal Degraded (Sd) condition shall exist on this uplink before initiating a switchover. Switchover…
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.5ColumnpdnLinkFailureSfPeriodBeforeSwitchingread-writecurrentThis object allows users to configure the amount of time a Signal Failure Bit (Sf) condition shall exist on this uplink before initiating a switchover. Switcho…
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6ColumnpdnLinkFailureSdBerThresholdread-writecurrentThis object allows users to configure the threshold for the Signal Degrade Bit Error Rate (Sd). The negated value of this number is used as the exponent of 10 …
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.7ColumnpdnLinkFailureSfBerThresholdread-writecurrentThis object allows users to configure the threshold for the Signal Failure Bit Error Rate (Sf). The negated value of this number is used as the exponent of 10 …
1.3.6.1.4.1.1795.2.24.2.40.1.1.4ScalarpdnDualLinkSelectionread-writecurrentThis object is used to enable or disable the ability to split traffic among dual links.
1.3.6.1.4.1.1795.2.24.2.40.1.2NodepdnLinkFaultMgmtMIBConformance
1.3.6.1.4.1.1795.2.24.2.40.1.2.1NodepdnLinkFaultMgmtCompliances
1.3.6.1.4.1.1795.2.24.2.40.1.2.1.1CompliancepdnLinkFaultMgmtComplianceread-onlycurrentThe compliance statement for SNMP entities capable of configuring link fault conditions.
1.3.6.1.4.1.1795.2.24.2.40.1.2.2NodepdnLinkFaultMgmtGroups
1.3.6.1.4.1.1795.2.24.2.40.1.2.2.1GrouppdnLinkFaultMgmtGeneralGroupcurrentA collection of configuration objects applicable to link fault mgmt implementation.
1.3.6.1.4.1.1795.2.24.2.40.1.2.2.2GrouppdnLinkSwitchoverGroupcurrentA collection of configuration objects applicable to all redundancy implementations.