This mib describes the SNMP functions of the Power Distribution Unit by Aphel Ltd.
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDateAndTime DisplayString MacAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.13742IdentityaphelThis mib describes the SNMP functions of the Power Distribution Unit by Aphel Ltd.
1.3.6.1.4.1.13742.2Nodepdu
1.3.6.1.4.1.13742.2.1Nodeboard
1.3.6.1.4.1.13742.2.1.1Nodeinfo
1.3.6.1.4.1.13742.2.1.1.1ScalarfirmwareVersionread-onlycurrentThe current firmware version
1.3.6.1.4.1.13742.2.1.1.2ScalarserialNumberread-onlycurrentThe serial number.
1.3.6.1.4.1.13742.2.1.1.3ScalaripAddressread-onlycurrentThe current IP address. A value of 0.0.0.0 indicates an error or an unset option.
1.3.6.1.4.1.13742.2.1.1.4Scalarnetmaskread-onlycurrentThe current Netmask. A value of 0.0.0.0 indicates an error or an unset option.
1.3.6.1.4.1.13742.2.1.1.5Scalargatewayread-onlycurrentThe current Gateway. A value of 0.0.0.0 indicates an error or an unset option.
1.3.6.1.4.1.13742.2.1.1.6Scalarmacread-onlycurrentThe current MAC address.
1.3.6.1.4.1.13742.2.1.1.7ScalarhardwareRevread-onlycurrentThe hardware revision number.
1.3.6.1.4.1.13742.2.1.1.10ScalaruserNamenot-accessiblecurrentThe login of a user.
1.3.6.1.4.1.13742.2.1.1.12ScalarobjectNamenot-accessiblecurrentThe model type of the device
1.3.6.1.4.1.13742.2.1.1.13ScalarobjectInstancenot-accessiblecurrentThe device name
1.3.6.1.4.1.13742.2.1.1.14ScalartargetUsernot-accessiblecurrentThe user record being operated on
1.3.6.1.4.1.13742.2.1.1.15ScalargroupNamenot-accessiblecurrentThe group record being operated on
1.3.6.1.4.1.13742.2.1.1.18ScalarimageVersionnot-accessiblecurrentThe version of the Upgrade image
1.3.6.1.4.1.13742.2.1.1.19Scalarstatusnot-accessiblecurrentThe success status of an operation
1.3.6.1.4.1.13742.2.1.1.20ScalaroutletNamenot-accessiblecurrentThe power outlet being operated on
1.3.6.1.4.1.13742.2.1.1.22ScalaroutletStatenot-accessiblecurrentThe state of a power outlet
1.3.6.1.4.1.13742.2.1.1.23ScalarsensorNumbernot-accessiblecurrentThe sensor number.
1.3.6.1.4.1.13742.2.1.1.24ScalarsensorEventnot-accessiblecurrentThe sensor event.
1.3.6.1.4.1.13742.2.1.2Nodeoutlets
1.3.6.1.4.1.13742.2.1.2.1ScalaroutletCountread-onlycurrentThe number of outlets (regardless of their current state) present on this pdu.
1.3.6.1.4.1.13742.2.1.2.2TableoutletTablenot-accessiblecurrentA list of outlet entries. The number of entries is given by the value of ifNumber.
1.3.6.1.4.1.13742.2.1.2.2.1RowoutletEntrynot-accessiblecurrentAn outlet entry containing objects at the for a particular outlet.
1.3.6.1.4.1.13742.2.1.2.2.1.1ColumnoutletIndexread-onlycurrentA unique value for each outlet. Its value ranges between 1 and the value of outletNumber.
1.3.6.1.4.1.13742.2.1.2.2.1.2ColumnoutletLabelread-onlycurrentA textual string containing information about the outlet.
1.3.6.1.4.1.13742.2.1.2.2.1.3ColumnoutletOperationalStateread-writecurrentA value for each outlet which describes the operational state of the outlet. It is also used to set the operational state of the outlet
1.3.6.1.4.1.13742.2.1.2.2.1.4ColumnoutletSensorNumberRMSCurrentread-onlycurrentA unique value for the RMS current sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.5ColumnoutletSensorNumberRMSPhaseread-onlycurrentA unique value for the RMS phase sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.6ColumnoutletSensorNumberMaxRMSCurrentread-onlycurrentA unique value for the max. RMS current sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.7ColumnoutletSensorNumberTrueRMSPowerread-onlycurrentA unique value for the true RMS power sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.8ColumnoutletSensorNumberApparentRMSPowerread-onlycurrentA unique value for the apparent RMS power sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.9ColumnoutletSensorNumberMaxTrueRMSPowerread-onlycurrentA unique value for the max. true RMS power sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.10ColumnoutletSensorNumberAverageRealRMSPowerread-onlycurrentA unique value for the average real RMS power sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.11ColumnoutletSensorNumberRMSVoltageread-onlycurrentA unique value for the RMS voltage sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.2.2.1.12ColumnoutletSensorNumberFrequencyread-onlycurrentA unique value for the frequency sensor attached to the outlet. This is also an index into the sensors table sensorTable.
1.3.6.1.4.1.13742.2.1.3Nodesensors
1.3.6.1.4.1.13742.2.1.3.1ScalarsensorCountread-onlycurrentThe number of sensors (regardless of their current state) present on this pdu.
1.3.6.1.4.1.13742.2.1.3.2TablesensorTablenot-accessiblecurrentA list of sensors of the pdu. The number of entries is given by the value of sensorNumber.
1.3.6.1.4.1.13742.2.1.3.2.1RowsensorEntrynot-accessiblecurrentAn sensor entry containing objects at the for a particular sensor.
1.3.6.1.4.1.13742.2.1.3.2.1.1ColumnsensorIndexread-onlycurrentA unique value for each sensor. Its value ranges between 1 and may exceed the value of sensorNumber.
1.3.6.1.4.1.13742.2.1.3.2.1.2ColumnsensorLabelread-onlycurrentA textual string containing information about the sensor.
1.3.6.1.4.1.13742.2.1.3.2.1.3ColumnsensorTyperead-onlycurrentThe type of the sensor.
1.3.6.1.4.1.13742.2.1.3.2.1.4ColumnsensorValueread-onlycurrentThe value the sensor delivers. This value is provided as ASN_OPAQUE_FLOAT type. In case of an error or unavailability NaN is returned
1.3.6.1.4.1.13742.2.1.3.2.1.5ColumnsensorUnitread-onlycurrentA string that containes the unit of the value.
1.3.6.1.4.1.13742.2.1.3.2.1.6ColumnsensorStateread-onlycurrentTo state of the sensor.
1.3.6.1.4.1.13742.2.1.3.2.1.7ColumnsensorAssociatedOutletread-onlycurrentA unique value for the outlet the sensor is associated to, if any. This is also an index into the outlets table outletTable. An value of 0 indicates no associa…
1.3.6.1.4.1.13742.2.1.3.2.1.8ColumnsensorLowerNonCriticalThresholdread-writecurrentThe value for the lower non-critical threshold of the sensor. This value is provided as ASN_OPAQUE_FLOAT type. In case of an error or unavailability NaN is ret…
1.3.6.1.4.1.13742.2.1.3.2.1.9ColumnsensorUpperNonCriticalThresholdread-writecurrentThe value for the upper non-critical threshold of the sensor. This value is provided as ASN_OPAQUE_FLOAT type. In case of an error or unavailability NaN is ret…
1.3.6.1.4.1.13742.2.1.3.2.1.10ColumnsensorLowerCriticalThresholdread-writecurrentThe value for the lower critical threshold of the sensor. This value is provided as ASN_OPAQUE_FLOAT type. In case of an error or unavailability NaN is returne…
1.3.6.1.4.1.13742.2.1.3.2.1.11ColumnsensorUpperCriticalThresholdread-writecurrentThe value for the upper critical threshold of the sensor. This value is provided as ASN_OPAQUE_FLOAT type. In case of an error or unavailability NaN is returne…
1.3.6.1.4.1.13742.2.1.3.2.1.12ColumnsensorLowerNonRecoverableThresholdread-writecurrentThe value for the lower non-recoverable threshold of the sensor. This value is provided as ASN_OPAQUE_FLOAT type. In case of an error or unavailability NaN is …
1.3.6.1.4.1.13742.2.1.3.2.1.13ColumnsensorUpperNonRecoverableThresholdread-writecurrentThe value for the upper non-recoverable threshold of the sensor. This value is provided as ASN_OPAQUE_FLOAT type. In case of an error or unavailability NaN is …
1.3.6.1.4.1.13742.2.2Nodetraps
1.3.6.1.4.1.13742.2.2.1NotificationrebootStartedcurrentThe reboot process has started
1.3.6.1.4.1.13742.2.2.2NotificationrebootCompletedcurrentThe reboot process is complete
1.3.6.1.4.1.13742.2.2.3NotificationuserLogincurrentA user logged in
1.3.6.1.4.1.13742.2.2.4NotificationuserLogoutcurrentA user logged out
1.3.6.1.4.1.13742.2.2.5NotificationuserAuthenticationFailurecurrentA user authentication attempt failed
1.3.6.1.4.1.13742.2.2.8NotificationuserSessionTimeoutcurrentA user timed out from the device
1.3.6.1.4.1.13742.2.2.11NotificationuserAddedcurrentA user was added to the system
1.3.6.1.4.1.13742.2.2.12NotificationuserModifiedcurrentA user account was modified
1.3.6.1.4.1.13742.2.2.13NotificationuserDeletedcurrentA user was deleted from the system
1.3.6.1.4.1.13742.2.2.14NotificationgroupAddedcurrentA group was added to the system
1.3.6.1.4.1.13742.2.2.15NotificationgroupModifiedcurrentA group was modified
1.3.6.1.4.1.13742.2.2.16NotificationgroupDeletedcurrentA group was deleted from the system
1.3.6.1.4.1.13742.2.2.20NotificationdeviceUpdateStartedcurrentThe device update has started
1.3.6.1.4.1.13742.2.2.22NotificationuserBlockedcurrentA blocked user tried to log in
1.3.6.1.4.1.13742.2.2.23NotificationpowerControlcurrentAn outlet has been switched
1.3.6.1.4.1.13742.2.2.24NotificationuserPasswordChangedcurrentA user password was changed
1.3.6.1.4.1.13742.2.2.27NotificationpowerSensorscurrentAn sensor event has been triggered
1.3.6.1.4.1.13742.2.2.28NotificationpasswordSettingsChangedcurrentStrong password settings changed
1.3.6.1.4.1.13742.2.2.36NotificationfirmwareFileDiscardedcurrentA firmware file discarded
1.3.6.1.4.1.13742.2.2.38NotificationfirmwareValidationFailedcurrentA firmware validation failed
1.3.6.1.4.1.13742.2.2.39NotificationsecurityViolationcurrentSecurity violation.
1.3.6.1.4.1.13742.2.2.40NotificationdeviceUpdateFailedcurrentDevice update has failed.
1.3.6.1.4.1.13742.2.2.41NotificationlogFileClearedcurrentThe log file has been cleared.