PM-MIB
293 objects
This module defines the Avocent MIB extensions to PM-PDU products.
Imported Objects
| IF-MIB | InterfaceIndex InterfaceIndexOrZero |
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.10418.17 | Identitypm | This module defines the Avocent MIB extensions to PM-PDU products. | ||
| 1.3.6.1.4.1.10418.17.1 | NodepmProducts | |||
| 1.3.6.1.4.1.10418.17.1.1 | Nodepm1024 | |||
| 1.3.6.1.4.1.10418.17.1.2 | Nodepm2003 | |||
| 1.3.6.1.4.1.10418.17.1.3 | Nodepm2006 | |||
| 1.3.6.1.4.1.10418.17.1.4 | Nodepm2024 | |||
| 1.3.6.1.4.1.10418.17.1.5 | Nodepm3003 | |||
| 1.3.6.1.4.1.10418.17.1.6 | Nodepm3006 | |||
| 1.3.6.1.4.1.10418.17.1.7 | Nodepm3024 | |||
| 1.3.6.1.4.1.10418.17.1.8 | Nodepm1010 | |||
| 1.3.6.1.4.1.10418.17.1.9 | Nodepm2010 | |||
| 1.3.6.1.4.1.10418.17.1.10 | Nodepm3010 | |||
| 1.3.6.1.4.1.10418.17.1.11 | Nodepm1020 | |||
| 1.3.6.1.4.1.10418.17.1.12 | Nodepm2020 | |||
| 1.3.6.1.4.1.10418.17.1.13 | Nodepm3020 | |||
| 1.3.6.1.4.1.10418.17.2 | NodepmManagement | |||
| 1.3.6.1.4.1.10418.17.2.1 | NodepmAppliance | |||
| 1.3.6.1.4.1.10418.17.2.1.1 | ScalarpmHostName | read-only | current | The appliance name |
| 1.3.6.1.4.1.10418.17.2.1.2 | ScalarpmProductModel | read-only | current | The appliance product model |
| 1.3.6.1.4.1.10418.17.2.1.3 | ScalarpmPartNumber | read-only | current | The part number of this appliance as shown on the label attached or imprinted on the appliance. |
| 1.3.6.1.4.1.10418.17.2.1.4 | ScalarpmSerialNumber | read-only | current | The serial number of this appliance as shown on the label attached or imprinted on the appliance. |
| 1.3.6.1.4.1.10418.17.2.1.5 | ScalarpmEIDNumber | read-only | current | The electronic ID number (EID) of this appliance as shown on the label attached or imprinted on the appliance. |
| 1.3.6.1.4.1.10418.17.2.1.6 | ScalarpmBootcodeVersion | read-only | current | The version of the bootcode of this appliance. |
| 1.3.6.1.4.1.10418.17.2.1.7 | ScalarpmFirmwareVersion | read-only | current | The version of the firmware of this appliance. |
| 1.3.6.1.4.1.10418.17.2.1.9 | ScalarpmReboot | read-write | current | A set value of reboot(2) will reboot the appliance. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the appliance immediately… |
| 1.3.6.1.4.1.10418.17.2.2 | NodepmSessions | |||
| 1.3.6.1.4.1.10418.17.2.2.1 | ScalarpmActiveSessionsNumberOfSession | read-only | current | Number of active sessions. |
| 1.3.6.1.4.1.10418.17.2.2.2 | TablepmActiveSessionsTable | not-accessible | current | This table contains the list of active sessions. |
| 1.3.6.1.4.1.10418.17.2.2.2.1 | RowpmActiveSessionsTableEntry | not-accessible | current | each entry has the information about the active session |
| 1.3.6.1.4.1.10418.17.2.2.2.1.1 | ColumnpmActiveSessionsTableIndex | read-only | current | A unique index representing an entry in this table. |
| 1.3.6.1.4.1.10418.17.2.2.2.1.2 | ColumnpmActiveSessionsTableUser | read-only | current | The name of the user that opens this session. |
| 1.3.6.1.4.1.10418.17.2.2.2.1.3 | ColumnpmActiveSessionsTableGroup | read-only | current | The name of the group that the user belongs to. |
| 1.3.6.1.4.1.10418.17.2.2.2.1.4 | ColumnpmActiveSessionsTableType | read-only | current | The session type. |
| 1.3.6.1.4.1.10418.17.2.2.2.1.5 | ColumnpmActiveSessionsTableConnection | read-only | current | Connection type. |
| 1.3.6.1.4.1.10418.17.2.2.2.1.6 | ColumnpmActiveSessionsTableSessionTime | read-only | current | Time of the session |
| 1.3.6.1.4.1.10418.17.2.2.2.1.7 | ColumnpmActiveSessionsTableFrom | read-only | current | The source IP address of the session. |
| 1.3.6.1.4.1.10418.17.2.2.2.1.8 | ColumnpmActiveSessionsTableKill | read-write | current | A set value of killSession(2) will kill the session. noAction(1) = always returned in a GET. Does nothing if SET. killSession(2)= when SET the appliance immedi… |
| 1.3.6.1.4.1.10418.17.2.5 | NodepmPowerMgmt | |||
| 1.3.6.1.4.1.10418.17.2.5.1 | ScalarpmPowerMgmtNumSerialPorts | read-only | current | The number of Serial Ports that has PDU connected on the appliance. |
| 1.3.6.1.4.1.10418.17.2.5.2 | TablepmPowerMgmtSerialTable | not-accessible | current | Information about each serial port thas has PDU connect. |
| 1.3.6.1.4.1.10418.17.2.5.2.1 | RowpmPowerMgmtSerialTableEntry | not-accessible | current | Information about each serial port thas has PDU connect. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.1 | ColumnpmPowerMgmtSerialTableIndex | read-only | current | The index of the register. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.2 | ColumnpmPowerMgmtSerialTablePortNumber | read-only | current | The number of the serial port when the PDU is connected. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.3 | ColumnpmPowerMgmtSerialTableDeviceName | read-only | current | The device name of this serial port. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.4 | ColumnpmPowerMgmtSerialTableNumberPDUs | read-only | current | Total number of units connected in this serial port. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.10 | ColumnpmPowerMgmtSerialTableBuzzer | read-write | current | set/get buzzer(s) on or off for the chain. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.11 | ColumnpmPowerMgmtSerialTableSyslog | read-write | current | set/get syslog on or off for the chain. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.12 | ColumnpmPowerMgmtSerialTableOverCurrent | read-write | current | set/get over current proctection on or off for the chain. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.13 | ColumnpmPowerMgmtSerialTableCycleInterval | read-write | current | set/get cycle interval for the chain in whole seconds. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.14 | ColumnpmPowerMgmtSerialTablePollRate | read-write | current | set/get the poll rate for the chain in whole seconds. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.15 | ColumnpmPowerMgmtSerialTablePassWord | read-write | current | set the global password for admin user |
| 1.3.6.1.4.1.10418.17.2.5.2.1.20 | ColumnpmPowerMgmtSerialTableSave | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. save(2) = when SET the save command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.2.1.21 | ColumnpmPowerMgmtSerialTableRestore | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. restore(2) = when SET the restore command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3 | TablepmPowerMgmtPDUTable | not-accessible | current | This table contains the list of detected PDUs. |
| 1.3.6.1.4.1.10418.17.2.5.3.1 | RowpmPowerMgmtPDUTableEntry | not-accessible | current | each entry has the information about the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.1 | ColumnpmPowerMgmtPDUTablePortNumber | read-only | current | Number of serial port when the PDU is connected. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.2 | ColumnpmPowerMgmtPDUTablePduIndex | read-only | current | A PDU position in the chain. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.3 | ColumnpmPowerMgmtPDUTablePduId | read-write | current | PDU identification. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.4 | ColumnpmPowerMgmtPDUTablePortName | read-only | current | Name of serial port when the PDU is connected. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.5 | ColumnpmPowerMgmtPDUTableModel | read-only | current | Model of the PDU. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.6 | ColumnpmPowerMgmtPDUTableVendor | read-only | current | Vendor of the PDU. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.7 | ColumnpmPowerMgmtPDUTableFirmwareVersion | read-only | current | Version of the PDU firmware. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.8 | ColumnpmPowerMgmtPDUTableNumberOfOutlets | read-only | current | Number of outlets of the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.9 | ColumnpmPowerMgmtPDUTableCurrentNOS | read-only | obsolete | Number of current sensors in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.10 | ColumnpmPowerMgmtPDUTableCurrent1Value | read-only | obsolete | Current of the sensor 1 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : valu… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.11 | ColumnpmPowerMgmtPDUTableCurrent1Max | read-write | obsolete | Maximum current of the sensor 1 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.12 | ColumnpmPowerMgmtPDUTableCurrent2Value | read-only | obsolete | Current of the sensor 2 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : valu… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.13 | ColumnpmPowerMgmtPDUTableCurrent2Max | read-write | obsolete | Maximum current of the sensor 2 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.14 | ColumnpmPowerMgmtPDUTableCurrent3Value | read-only | obsolete | Current of the sensor 3 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : valu… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.15 | ColumnpmPowerMgmtPDUTableCurrent3Max | read-write | obsolete | Maximum current of the sensor 3 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.16 | ColumnpmPowerMgmtPDUTableTemperatureNOS | read-only | obsolete | Number of temperature sensors in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.17 | ColumnpmPowerMgmtPDUTableTemperature1Value | read-only | obsolete | Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (E… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.18 | ColumnpmPowerMgmtPDUTableTemperature1Max | read-write | obsolete | Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.19 | ColumnpmPowerMgmtPDUTableTemperature2Value | read-only | obsolete | Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (E… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.20 | ColumnpmPowerMgmtPDUTableTemperature2Max | read-write | obsolete | Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.21 | ColumnpmPowerMgmtPDUTableTemperature3Value | read-only | obsolete | Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (E… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.22 | ColumnpmPowerMgmtPDUTableTemperature3Max | read-write | obsolete | Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.23 | ColumnpmPowerMgmtPDUTableHumidityNOS | read-only | obsolete | Number of humidity sensors in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.24 | ColumnpmPowerMgmtPDUTableHumidity1Value | read-only | obsolete | Humidity of this PM unit . If the humidity measurement is not installed this value will be 0. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.25 | ColumnpmPowerMgmtPDUTableHumidity1Max | read-write | obsolete | Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.26 | ColumnpmPowerMgmtPDUTableHumidity2Value | read-only | obsolete | Humidity of this PM unit . If the humidity measurement is not installed this value will be 0. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.27 | ColumnpmPowerMgmtPDUTableHumidity2Max | read-write | obsolete | Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.28 | ColumnpmPowerMgmtPDUTableHumidity3Value | read-only | obsolete | Humidity of this PM unit . If the humidity measurement is not installed this value will be 0. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.29 | ColumnpmPowerMgmtPDUTableHumidity3Max | read-write | obsolete | Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.30 | ColumnpmPowerMgmtPDUTableVoltageNOS | read-only | obsolete | Number of voltage sensors in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.31 | ColumnpmPowerMgmtPDUTableVoltage1Value | read-only | obsolete | Voltage of this sensor in this PDU unit. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageValue, pmPowerMgmtPhasesTableVoltageV… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.32 | ColumnpmPowerMgmtPDUTableVoltage1Max | read-write | obsolete | Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. This OID is obsoleted. The value can be retrieved from pmPow… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.33 | ColumnpmPowerMgmtPDUTableVoltage2Value | read-only | obsolete | Voltage of this sensor in this PDU unit. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageValue, pmPowerMgmtPhasesTableVoltageV… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.34 | ColumnpmPowerMgmtPDUTableVoltage2Max | read-write | obsolete | Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. This OID is obsoleted. The value can be retrieved from pmPow… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.35 | ColumnpmPowerMgmtPDUTableVoltage3Value | read-only | obsolete | Voltage of this sensor in this PDU unit. This OID is obsoleted. The value can be retrieved from pmPowerMgmtPDUTableVoltageValue, pmPowerMgmtPhasesTableVoltageV… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.36 | ColumnpmPowerMgmtPDUTableVoltage3Max | read-write | obsolete | Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. This OID is obsoleted. The value can be retrieved from pmPow… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.37 | ColumnpmPowerMgmtPDUTableNumberOfPhases | read-only | current | Number of phases of the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.38 | ColumnpmPowerMgmtPDUTableNumberOfBanks | read-only | current | Number of banks in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.40 | ColumnpmPowerMgmtPDUTableNumberOfSensors | read-only | current | Number of sensors in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.41 | ColumnpmPowerMgmtPDUTableFactoryDefault | read-write | current | A set value of 2 will set the PDU to factory default settings. noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the factory def… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.42 | ColumnpmPowerMgmtPDUTableColdStartDelay | read-write | current | PDUs cold start delay in whole seconds (0-60). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.43 | ColumnpmPowerMgmtPDUTableReboot | read-write | current | A set value of power*(2) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the reboot command is sent… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.44 | ColumnpmPowerMgmtPDUTableMaxCurrent | read-only | current | Maximum value of current allowed in the PDU (A x 10). |
| 1.3.6.1.4.1.10418.17.2.5.3.1.45 | ColumnpmPowerMgmtPDUTableAlarm | read-only | current | Show the PDU alarm status. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.50 | ColumnpmPowerMgmtPDUTableCurrentValue | read-only | current | Actual value of current in the PDU (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.51 | ColumnpmPowerMgmtPDUTableCurrentMax | read-only | current | Maximum value of current in the PDU (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.52 | ColumnpmPowerMgmtPDUTableCurrentMin | read-only | current | Minimum value of current in the PDU (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.53 | ColumnpmPowerMgmtPDUTableCurrentAvg | read-only | current | Average value of current in the PDU (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.54 | ColumnpmPowerMgmtPDUTableCurrentReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.60 | ColumnpmPowerMgmtPDUTablePowerValue | read-only | current | Actual value of power in the PDU (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.61 | ColumnpmPowerMgmtPDUTablePowerMax | read-only | current | Maximum value of power in the PDU (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.62 | ColumnpmPowerMgmtPDUTablePowerMin | read-only | current | Minimum value of power in the PDU (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.63 | ColumnpmPowerMgmtPDUTablePowerAvg | read-only | current | Average value of power in the PDU (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.64 | ColumnpmPowerMgmtPDUTablePowerReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.65 | ColumnpmPowerMgmtPDUTablePowerType | read-only | current | Type of power values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.70 | ColumnpmPowerMgmtPDUTableVoltageValue | read-only | current | Actual value of voltage in the PDU (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.71 | ColumnpmPowerMgmtPDUTableVoltageMax | read-only | current | Maximum value of voltage in the PDU (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.72 | ColumnpmPowerMgmtPDUTableVoltageMin | read-only | current | Minimum value of voltage in the PDU (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.73 | ColumnpmPowerMgmtPDUTableVoltageAvg | read-only | current | Average value of voltage in the PDU (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.74 | ColumnpmPowerMgmtPDUTableVoltageReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.75 | ColumnpmPowerMgmtPDUTableVoltageType | read-only | current | Type of voltage values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.80 | ColumnpmPowerMgmtPDUTablePowerFactorValue | read-only | current | Actual value of power factor in the PDU (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.81 | ColumnpmPowerMgmtPDUTablePowerFactorMax | read-only | current | Maximum value of power factor in the PDU (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.82 | ColumnpmPowerMgmtPDUTablePowerFactorMin | read-only | current | Minimum value of power factor in the PDU (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.83 | ColumnpmPowerMgmtPDUTablePowerFactorAvg | read-only | current | Average value of power factor in the PDU (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.84 | ColumnpmPowerMgmtPDUTablePowerFactorReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.85 | ColumnpmPowerMgmtPDUTablePowerFactorType | read-only | current | Type of power values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.90 | ColumnpmPowerMgmtPDUTablePowerControl | read-write | current | A set value of power*(2-4) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.91 | ColumnpmPowerMgmtPDUTableResetOCP | read-write | current | A set value of power*(2) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent t… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.100 | ColumnpmPowerMgmtPDUTableCurrentHighCritical | read-write | current | outlet high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.101 | ColumnpmPowerMgmtPDUTableCurrentHighWarning | read-write | current | outlet high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not support… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.102 | ColumnpmPowerMgmtPDUTableCurrentLowWarning | read-write | current | outlet low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supporte… |
| 1.3.6.1.4.1.10418.17.2.5.3.1.103 | ColumnpmPowerMgmtPDUTableCurrentLowCritical | read-write | current | outlet low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.105 | ColumnpmPowerMgmtPDUTableEnergyValue | read-only | current | pdu energy value (Wh). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.106 | ColumnpmPowerMgmtPDUTableEnergyStartTime | read-only | current | time at which energy calculation commenced (ISO8601 format). Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.3.1.107 | ColumnpmPowerMgmtPDUTableEnergyReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.4 | ScalarpmPowerMgmtTotalNumberOfOutlets | read-only | current | Number of outlets managed by the appliance. |
| 1.3.6.1.4.1.10418.17.2.5.5 | TablepmPowerMgmtOutletsTable | not-accessible | current | This table contains the information about outlets. |
| 1.3.6.1.4.1.10418.17.2.5.5.1 | RowpmPowerMgmtOutletsTableEntry | not-accessible | current | each entry has the information about the outlet. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.1 | ColumnpmPowerMgmtOutletsTablePortNumber | read-only | current | Serial Port number. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.2 | ColumnpmPowerMgmtOutletsTablePduNumber | read-only | current | Index. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.3 | ColumnpmPowerMgmtOutletsTableNumber | read-only | current | Number of the outlet in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.4 | ColumnpmPowerMgmtOutletsTableName | read-write | current | Name of the outlet. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.5 | ColumnpmPowerMgmtOutletsTableStatus | read-only | current | Status of the outlet. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.6 | ColumnpmPowerMgmtOutletsTablePowerControl | read-write | current | A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is… |
| 1.3.6.1.4.1.10418.17.2.5.5.1.7 | ColumnpmPowerMgmtOutletsTablePortName | read-only | current | Serial Port Name where the PDU is connected. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.8 | ColumnpmPowerMgmtOutletsTablePduId | read-only | current | PDU identification. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.9 | ColumnpmPowerMgmtOutletsTablePostOnDelay | read-write | current | post on delay for the outlet (seconds x 10) Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.10 | ColumnpmPowerMgmtOutletsTablePostOffDelay | read-write | current | post off delay for the outlet (seconds x 10) Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.45 | ColumnpmPowerMgmtOutletsTableAlarm | read-only | current | Show the outlet alarm status. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.50 | ColumnpmPowerMgmtOutletsTableCurrentValue | read-only | current | Actual value of current in the outlet (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.51 | ColumnpmPowerMgmtOutletsTableCurrentMax | read-only | current | Maximum value of current in the outlet (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.52 | ColumnpmPowerMgmtOutletsTableCurrentMin | read-only | current | Minimum value of current in the outlet (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.53 | ColumnpmPowerMgmtOutletsTableCurrentAvg | read-only | current | Average value of current in the outlet (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.54 | ColumnpmPowerMgmtOutletsTableCurrentReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.60 | ColumnpmPowerMgmtOutletsTablePowerValue | read-only | current | Actual value of power in the outlet (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.61 | ColumnpmPowerMgmtOutletsTablePowerMax | read-only | current | Maximum value of power in the outlet (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.62 | ColumnpmPowerMgmtOutletsTablePowerMin | read-only | current | Minimum value of power in the outlet (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.63 | ColumnpmPowerMgmtOutletsTablePowerAvg | read-only | current | Average value of power in the outlet (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.64 | ColumnpmPowerMgmtOutletsTablePowerReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.65 | ColumnpmPowerMgmtOutletsTablePowerType | read-only | current | Type of power values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.70 | ColumnpmPowerMgmtOutletsTableVoltageValue | read-only | current | Actual value of voltage in the outlet (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.71 | ColumnpmPowerMgmtOutletsTableVoltageMax | read-only | current | Maximum value of voltage in the outlet (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.72 | ColumnpmPowerMgmtOutletsTableVoltageMin | read-only | current | Minimum value of voltage in the outlet (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.73 | ColumnpmPowerMgmtOutletsTableVoltageAvg | read-only | current | Average value of voltage in the outlet (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.74 | ColumnpmPowerMgmtOutletsTableVoltageReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.75 | ColumnpmPowerMgmtOutletsTableVoltageType | read-only | current | Type of voltage values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.80 | ColumnpmPowerMgmtOutletsTablePowerFactorValue | read-only | current | Actual value of power factor in the outlet (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.81 | ColumnpmPowerMgmtOutletsTablePowerFactorMax | read-only | current | Maximum value of power factor in the outlet (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.82 | ColumnpmPowerMgmtOutletsTablePowerFactorMin | read-only | current | Minimum value of power factor in the outlet (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.83 | ColumnpmPowerMgmtOutletsTablePowerFactorAvg | read-only | current | Average value of power factor in the outlet (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.84 | ColumnpmPowerMgmtOutletsTablePowerFactorReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.85 | ColumnpmPowerMgmtOutletsTablePowerFactorType | read-only | current | Type of power factor values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.100 | ColumnpmPowerMgmtOutletsTableCurrentHighCritical | read-write | current | outlet high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.101 | ColumnpmPowerMgmtOutletsTableCurrentHighWarning | read-write | current | outlet high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not support… |
| 1.3.6.1.4.1.10418.17.2.5.5.1.102 | ColumnpmPowerMgmtOutletsTableCurrentLowWarning | read-write | current | outlet low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supporte… |
| 1.3.6.1.4.1.10418.17.2.5.5.1.103 | ColumnpmPowerMgmtOutletsTableCurrentLowCritical | read-write | current | outlet low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.105 | ColumnpmPowerMgmtOutletsTableEnergyValue | read-only | current | outlet energy value (Wh). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.106 | ColumnpmPowerMgmtOutletsTableEnergyStartTime | read-only | current | time at which energy calculation commenced (ISO8601 format). Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.5.1.107 | ColumnpmPowerMgmtOutletsTableEnergyReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.6 | ScalarpmPowerMgmtNumberOfOutletGroup | read-only | current | Number of configured group of outlets. |
| 1.3.6.1.4.1.10418.17.2.5.7 | TablepmPowerMgmtGroupTable | not-accessible | current | This table contains the information about group of outlets. |
| 1.3.6.1.4.1.10418.17.2.5.7.1 | RowpmPowerMgmtGroupTableEntry | not-accessible | current | each entry has the information about group of outlets. |
| 1.3.6.1.4.1.10418.17.2.5.7.1.1 | ColumnpmPowerMgmtGroupTableIndex | read-only | current | Index of the group. |
| 1.3.6.1.4.1.10418.17.2.5.7.1.2 | ColumnpmPowerMgmtGroupTableName | read-only | current | Name of the group of outlets. |
| 1.3.6.1.4.1.10418.17.2.5.7.1.3 | ColumnpmPowerMgmtGroupTableStatus | read-only | current | Status of the group of outlet. |
| 1.3.6.1.4.1.10418.17.2.5.7.1.4 | ColumnpmPowerMgmtGroupTablePowerControl | read-write | current | A set value of power*(2-4) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is… |
| 1.3.6.1.4.1.10418.17.2.5.8 | ScalarpmPowerMgmtTotalNumberOfPhases | read-only | current | Number of phases managed by the appliance. |
| 1.3.6.1.4.1.10418.17.2.5.9 | TablepmPowerMgmtPhasesTable | not-accessible | current | This table contains the information about phases. |
| 1.3.6.1.4.1.10418.17.2.5.9.1 | RowpmPowerMgmtPhasesTableEntry | not-accessible | current | each entry has the information about the phases. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.1 | ColumnpmPowerMgmtPhasesTablePortNumber | read-only | current | Serial Port number. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.2 | ColumnpmPowerMgmtPhasesTablePduNumber | read-only | current | Index. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.3 | ColumnpmPowerMgmtPhasesTableNumber | read-only | current | Number of the phase in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.4 | ColumnpmPowerMgmtPhasesTableName | read-only | current | Name of the phase. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.5 | ColumnpmPowerMgmtPhasesTablePortName | read-only | current | Serial Port Name where the PDU is connected. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.6 | ColumnpmPowerMgmtPhasesTablePduId | read-only | current | PDU identification. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.45 | ColumnpmPowerMgmtPhasesTableAlarm | read-only | current | Show the phase alarm status. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.50 | ColumnpmPowerMgmtPhasesTableCurrentValue | read-only | current | Actual value of current in the phase (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.51 | ColumnpmPowerMgmtPhasesTableCurrentMax | read-only | current | Maximum value of current in the phase (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.52 | ColumnpmPowerMgmtPhasesTableCurrentMin | read-only | current | Minimum value of current in the phase (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.53 | ColumnpmPowerMgmtPhasesTableCurrentAvg | read-only | current | Average value of current in the phase (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.54 | ColumnpmPowerMgmtPhasesTableCurrentReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.60 | ColumnpmPowerMgmtPhasesTablePowerValue | read-only | current | Actual value of power in the phase (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.61 | ColumnpmPowerMgmtPhasesTablePowerMax | read-only | current | Maximum value of power in the phase (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.62 | ColumnpmPowerMgmtPhasesTablePowerMin | read-only | current | Minimum value of power in the phase (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.63 | ColumnpmPowerMgmtPhasesTablePowerAvg | read-only | current | Average value of power in the phase (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.64 | ColumnpmPowerMgmtPhasesTablePowerReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.65 | ColumnpmPowerMgmtPhasesTablePowerType | read-only | current | Type of power values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.70 | ColumnpmPowerMgmtPhasesTableVoltageValue | read-only | current | Actual value of voltage in the phase (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.71 | ColumnpmPowerMgmtPhasesTableVoltageMax | read-only | current | Maximum value of voltage in the phase (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.72 | ColumnpmPowerMgmtPhasesTableVoltageMin | read-only | current | Minimum value of voltage in the phase (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.73 | ColumnpmPowerMgmtPhasesTableVoltageAvg | read-only | current | Average value of voltage in the phase (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.74 | ColumnpmPowerMgmtPhasesTableVoltageReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.75 | ColumnpmPowerMgmtPhasesTableVoltageType | read-only | current | Type of voltage values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.80 | ColumnpmPowerMgmtPhasesTablePowerFactorValue | read-only | current | Actual value of power factor in the phase (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.81 | ColumnpmPowerMgmtPhasesTablePowerFactorMax | read-only | current | Maximum value of power factor in the phase (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.82 | ColumnpmPowerMgmtPhasesTablePowerFactorMin | read-only | current | Minimum value of power factor in the phase (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.83 | ColumnpmPowerMgmtPhasesTablePowerFactorAvg | read-only | current | Average value of power factor in the phase (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.84 | ColumnpmPowerMgmtPhasesTablePowerFactorReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.85 | ColumnpmPowerMgmtPhasesTablePowerFactorType | read-only | current | Type of power factor values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.100 | ColumnpmPowerMgmtPhasesTableCurrentHighCritical | read-write | current | phase high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.101 | ColumnpmPowerMgmtPhasesTableCurrentHighWarning | read-write | current | phase high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not supporte… |
| 1.3.6.1.4.1.10418.17.2.5.9.1.102 | ColumnpmPowerMgmtPhasesTableCurrentLowWarning | read-write | current | phase low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.9.1.103 | ColumnpmPowerMgmtPhasesTableCurrentLowCritical | read-write | current | phase low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.10 | ScalarpmPowerMgmtTotalNumberOfBanks | read-only | current | Number of banks managed by the appliance. |
| 1.3.6.1.4.1.10418.17.2.5.11 | TablepmPowerMgmtBanksTable | not-accessible | current | This table contains the information about banks. |
| 1.3.6.1.4.1.10418.17.2.5.11.1 | RowpmPowerMgmtBanksTableEntry | not-accessible | current | each entry has the information about the banks. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.1 | ColumnpmPowerMgmtBanksTablePortNumber | read-only | current | Serial Port number. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.2 | ColumnpmPowerMgmtBanksTablePduNumber | read-only | current | Index. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.3 | ColumnpmPowerMgmtBanksTableNumber | read-only | current | Number of the bank in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.4 | ColumnpmPowerMgmtBanksTableName | read-only | current | Name of the bank. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.5 | ColumnpmPowerMgmtBanksTablePortName | read-only | current | Serial Port Name where the PDU is connected. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.6 | ColumnpmPowerMgmtBanksTablePduId | read-only | current | PDU identification. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.45 | ColumnpmPowerMgmtBanksTableAlarm | read-only | current | Show the bank alarm status. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.50 | ColumnpmPowerMgmtBanksTableCurrentValue | read-only | current | Actual value of current in the bank (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.51 | ColumnpmPowerMgmtBanksTableCurrentMax | read-only | current | Maximum value of current in the bank (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.52 | ColumnpmPowerMgmtBanksTableCurrentMin | read-only | current | Minimum value of current in the bank (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.53 | ColumnpmPowerMgmtBanksTableCurrentAvg | read-only | current | Average value of current in the bank (A x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.54 | ColumnpmPowerMgmtBanksTableCurrentReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.60 | ColumnpmPowerMgmtBanksTablePowerValue | read-only | current | Actual value of power in the bank (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.61 | ColumnpmPowerMgmtBanksTablePowerMax | read-only | current | Maximum value of power in the bank (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.62 | ColumnpmPowerMgmtBanksTablePowerMin | read-only | current | Minimum value of power in the bank (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.63 | ColumnpmPowerMgmtBanksTablePowerAvg | read-only | current | Average value of power in the bank (W x 10). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.64 | ColumnpmPowerMgmtBanksTablePowerReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.65 | ColumnpmPowerMgmtBanksTablePowerType | read-only | current | Type of power values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.70 | ColumnpmPowerMgmtBanksTableVoltageValue | read-only | current | Actual value of voltage in the bank (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.71 | ColumnpmPowerMgmtBanksTableVoltageMax | read-only | current | Maximum value of voltage in the bank (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.72 | ColumnpmPowerMgmtBanksTableVoltageMin | read-only | current | Minimum value of voltage in the bank (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.73 | ColumnpmPowerMgmtBanksTableVoltageAvg | read-only | current | Average value of voltage in the bank (V). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.74 | ColumnpmPowerMgmtBanksTableVoltageReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.75 | ColumnpmPowerMgmtBanksTableVoltageType | read-only | current | Type of voltage values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.80 | ColumnpmPowerMgmtBanksTablePowerFactorValue | read-only | current | Actual value of power factor in the bank (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.81 | ColumnpmPowerMgmtBanksTablePowerFactorMax | read-only | current | Maximum value of power factor in the bank (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.82 | ColumnpmPowerMgmtBanksTablePowerFactorMin | read-only | current | Minimum value of power factor in the bank (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.83 | ColumnpmPowerMgmtBanksTablePowerFactorAvg | read-only | current | Average value of power factor in the bank (Pf x 100). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.84 | ColumnpmPowerMgmtBanksTablePowerFactorReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.85 | ColumnpmPowerMgmtBanksTablePowerFactorType | read-only | current | Type of power factor values. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.100 | ColumnpmPowerMgmtBanksTableCurrentHighCritical | read-write | current | bank high critical (alarm) current threshold (A x 10). Set fails if value is lower that CurrentHighWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.101 | ColumnpmPowerMgmtBanksTableCurrentHighWarning | read-write | current | bank high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.102 | ColumnpmPowerMgmtBanksTableCurrentLowWarning | read-write | current | bank low warning current threshold (A x 10). Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.103 | ColumnpmPowerMgmtBanksTableCurrentLowCritical | read-write | current | bank low critical current threshold (A x 10). Set fails if value is higher than CurrentLowWarning. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.105 | ColumnpmPowerMgmtBanksTableEnergyValue | read-only | current | bank energy value (Wh). Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.106 | ColumnpmPowerMgmtBanksTableEnergyStartTime | read-only | current | time at which energy calculation commenced (ISO8601 format). Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.11.1.107 | ColumnpmPowerMgmtBanksTableEnergyReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to PDU. |
| 1.3.6.1.4.1.10418.17.2.5.12 | ScalarpmPowerMgmtTotalNumberOfSensors | read-only | current | Number of Sensors managed by the appliance. |
| 1.3.6.1.4.1.10418.17.2.5.13 | TablepmPowerMgmtSensorsTable | not-accessible | current | This table contains the information about sensors. |
| 1.3.6.1.4.1.10418.17.2.5.13.1 | RowpmPowerMgmtSensorsTableEntry | not-accessible | current | each entry has the information about the sensors. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.1 | ColumnpmPowerMgmtSensorsTablePortNumber | read-only | current | Serial Port number. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.2 | ColumnpmPowerMgmtSensorsTablePduNumber | read-only | current | Index. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.3 | ColumnpmPowerMgmtSensorsTableNumber | read-only | current | Number of the sensor in the PDU. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.4 | ColumnpmPowerMgmtSensorsTableName | read-write | current | Name of the sensor. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.5 | ColumnpmPowerMgmtSensorsTablePortName | read-only | current | Serial Port Name where the PDU is connected. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.6 | ColumnpmPowerMgmtSensorsTablePduId | read-only | current | PDU identification. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.7 | ColumnpmPowerMgmtSensorsTableType | read-only | current | The type of environmental monitor. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.8 | ColumnpmPowerMgmtSensorsTableStatus | read-only | current | Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.20 | ColumnpmPowerMgmtSensorsTableValue | read-only | current | Actual value of the sensor. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.21 | ColumnpmPowerMgmtSensorsTableValueMax | read-only | current | Maximum value of the sensor. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.22 | ColumnpmPowerMgmtSensorsTableValueMin | read-only | current | Minimum value of the sensor. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.23 | ColumnpmPowerMgmtSensorsTableValueAvg | read-only | current | Average value of the sensor. Returns N/A if not applicable. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.25 | ColumnpmPowerMgmtSensorsTableValueInt | read-only | current | Actual value of the sensor. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.26 | ColumnpmPowerMgmtSensorsTableValueMaxInt | read-only | current | Maximum value of the sensor. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.27 | ColumnpmPowerMgmtSensorsTableValueMinInt | read-only | current | Minimum value of the sensor. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.28 | ColumnpmPowerMgmtSensorsTableValueAvgInt | read-only | current | Average value of the sensor. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.30 | ColumnpmPowerMgmtSensorsTableValueReset | read-write | current | noAction(1) = always returned in a GET. Does nothing if SET. reset(2) = when SET the reset command is sent to sensor. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.40 | ColumnpmPowerMgmtSensorsTableHighCritical | read-write | current | sensor high critical (alarm) threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is lower that CurrentHighWarning. … |
| 1.3.6.1.4.1.10418.17.2.5.13.1.41 | ColumnpmPowerMgmtSensorsTableHighWarning | read-write | current | sensor high warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is higher than HighCritical or lower than L… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.42 | ColumnpmPowerMgmtSensorsTableLowWarning | read-write | current | sensor low warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is higher than HighWarning or lower than Low… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.43 | ColumnpmPowerMgmtSensorsTableLowCritical | read-write | current | sensor low critical threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit. Set fails if value is higher than LowWarning. Returns 0 if not… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.45 | ColumnpmPowerMgmtSensorsTableUnit | read-write | current | sensor unit. Returns 0 if not supported. |
| 1.3.6.1.4.1.10418.17.2.5.13.1.50 | ColumnpmPowerMgmtSensorsTableHighCriticalC | read-only | current | sensor high critical (alarm) threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit). Returns 0… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.51 | ColumnpmPowerMgmtSensorsTableHighWarningC | read-only | current | sensor high warning threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not su… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.52 | ColumnpmPowerMgmtSensorsTableLowWarningC | read-only | current | sensor low warning threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not supp… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.53 | ColumnpmPowerMgmtSensorsTableLowCriticalC | read-only | current | sensor low critical threshold (Celcius x 10). to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not su… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.60 | ColumnpmPowerMgmtSensorsTableHighCriticalF | read-only | current | sensor high critical (alarm) threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit). Return… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.61 | ColumnpmPowerMgmtSensorsTableHighWarningF | read-only | current | sensor high warning threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.62 | ColumnpmPowerMgmtSensorsTableLowWarningF | read-only | current | sensor low warning threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not s… |
| 1.3.6.1.4.1.10418.17.2.5.13.1.63 | ColumnpmPowerMgmtSensorsTableLowCriticalF | read-only | current | sensor low critical threshold (Fahrenheit x 10). to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit). Returns 0 if not… |
| 1.3.6.1.4.1.10418.17.2.6 | NodepmTrapObject |