MIB Viewer

POEXMIB

86 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises
RFC1213-MIBDisplayString
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.41542Nodemanufacturer
1.3.6.1.4.1.41542.3NodePOEX
1.3.6.1.4.1.41542.3.1NodePOEXGatewaySpecificInfo
1.3.6.1.4.1.41542.3.1NodePOEXNewSensorTrafficThis trap, when enabled, will generate a report corresponding to new data from any registered sensor as it is received. Included with the trap message are the …
1.3.6.1.4.1.41542.3.1.1ScalarPOEXGatewayIDread-onlymandatoryThe serial number identifier of the gateway device assigned and programmed by the manufacturer. This will ordinarily be printed on a label on the housing of th…
1.3.6.1.4.1.41542.3.1.2ScalarPOEXGatewayFirmwareVerNoread-onlymandatoryThe version number of the firmware of the gateway device. Note that this can change upon a firmware update.
1.3.6.1.4.1.41542.3.1.3ScalarPOEXGatewaySensorDeviceCountread-onlymandatoryThe number of sensors registered to the gateway, i.e. on its netlist. Note that this can change as sensors are added or removed.
1.3.6.1.4.1.41542.3.1.4ScalarPOEXGatewayTrapIPAddrread-onlymandatoryThe configured destination IP address for trap messages from this gateway.
1.3.6.1.4.1.41542.3.1.5ScalarPOEXGatewaySensorTrapPortread-onlymandatoryThe configured IP port for trap messages from this gateway.
1.3.6.1.4.1.41542.3.2NodePOEXDeviceAlarmingThis trap, when enabled, will generate a report corresponding to new data from any registered sensor as it is received, but only if that sensor is alarming and…
1.3.6.1.4.1.41542.3.2TablePOEXSensorInfoTranslatedFormatTablenot-accessiblemandatoryThe (conceptual) table containing sensor-specific information in an easy-to-use translated string format, indexed by sensor ID is reported under this hierarchy…
1.3.6.1.4.1.41542.3.2.1RowPOEXSensorInfoTranslatedFormatEntrynot-accessiblemandatoryAn entry (conceptual row) in the Translated Format Table containing the latest sensor state for a single sensor.
1.3.6.1.4.1.41542.3.2.1.1ColumnPOEXSensorInfoTranslatedFormatSensorDeviceIDread-onlymandatoryThe serial number identifier of the sensor device assigned and programmed by the manufacturer. This will ordinarily be printed on a label on the housing of the…
1.3.6.1.4.1.41542.3.2.1.2ColumnPOEXSensorInfoTranslatedFormatSensorDeviceTyperead-onlymandatoryThe textual description of the type of the sensor device.
1.3.6.1.4.1.41542.3.2.1.3ColumnPOEXSensorInfoTranslatedFormatSensorDeviceReadingValuesAllread-onlymandatoryAll of the datums for the most recent reading of the sensor device, separated by commas, in textual format. For example, a report for a temperature and humidit…
1.3.6.1.4.1.41542.3.2.1.4ColumnPOEXSensorInfoTranslatedFormatSensorDeviceReadingUnitsAllread-onlymandatoryAll of the units corresponding to the datums for the most recent reading of the sensor device, separated by commas, in textual format. For example, for a senso…
1.3.6.1.4.1.41542.3.2.1.5ColumnPOEXSensorInfoTranslatedFormatSensorDeviceRptUTread-onlymandatoryThe untranslated data block received from a sensor, in hexadecimal format. This may be used where a translating function isn't yet present, and for development…
1.3.6.1.4.1.41542.3.2.1.6ColumnPOEXSensorInfoTranslatedFormatSensorDeviceReadingTimeread-onlymandatoryThe time of the sensor report received most recently from a sensor. That time is reported as the number of seconds elapsed since the epoch of the gateway, whic…
1.3.6.1.4.1.41542.3.2.1.7ColumnPOEXSensorInfoTranslatedFormatSensorDeviceReadingAgeread-onlymandatoryThe age of the sensor report received most recently from a sensor. That time is reported as the number of seconds between the time of the sensor report and the…
1.3.6.1.4.1.41542.3.2.1.8ColumnPOEXSensorInfoTranslatedFormatSensorDeviceTypeNoread-onlymandatoryThe manufacturer's type number that identifies the kind of sensor.
1.3.6.1.4.1.41542.3.2.1.9ColumnPOEXSensorInfoTranslatedFormatSensorDeviceRFStrengthread-onlymandatoryThe signal strength, in percent, of the radio link between the gateway and the particular sensor, as measured at the time of the most recent sensor report.
1.3.6.1.4.1.41542.3.2.1.10ColumnPOEXSensorInfoTranslatedFormatSensorDeviceActiveread-onlymandatoryEither 'Active' or '' (an empty string). A sensor will be reported active if it has recently communicated with the gateway since the last reboot. If a sensor d…
1.3.6.1.4.1.41542.3.2.1.11ColumnPOEXSensorInfoTranslatedFormatSensorDeviceAlarmingread-onlymandatoryEither 'Alarming' or 'Not alarming'. A device will report an alarm if it is programmed with a threshold found to be exceeded. Examples: a temperature sensor fo…
1.3.6.1.4.1.41542.3.2.1.12ColumnPOEXSensorInfoTranslatedFormatSensorDeviceVoltageread-onlymandatoryThe value of the voltage of the supply powering a sensor device. Ordinarily this will report the voltage at the battery terminals of a sensor. It is provided m…
1.3.6.1.4.1.41542.3.2.1.13ColumnPOEXSensorInfoTranslatedFormatSensorDeviceWDIndexNoread-onlymandatoryThe index number of the sensor in the gateway's sensor registration table. This is the number used in referencing the sensor in the POEXSensorInformationBySens…
1.3.6.1.4.1.41542.3.2.2RowPOEXSensorInfoTranslatedFormatByDatumNumberEntrynot-accessiblemandatoryAn entry (conceptual row) in the Translated Format Table containing the sensor datums, indexed by a sensor ID and datum number.
1.3.6.1.4.1.41542.3.2.2.1ColumnPOEXSensorInfoTranslatedFormatByDatumNumberSensorDeviceIDread-onlymandatoryThe serial number identifier of the sensor device assigned and programmed by the manufacturer. This will ordinarily be printed on a label on the housing of the…
1.3.6.1.4.1.41542.3.2.2.2ColumnPOEXSensorInfoTranslatedFormatByDatumNumberDatumNumberread-onlymandatoryThe number of a datum in a set of datums comprising a sensor reading. For sensors reporting one datum, this will always be one. Otherwise it will be a number b…
1.3.6.1.4.1.41542.3.2.2.3ColumnPOEXSensorInfoTranslatedFormatByDatumNumberReadingValueread-onlymandatoryThe value of a sensor reading, in textual format, translated according to sensor and datum types. These formats can include integers, fixed-point, and binary v…
1.3.6.1.4.1.41542.3.2.2.4ColumnPOEXSensorInfoTranslatedFormatByDatumNumberReadingUnitsread-onlymandatoryThe units or scale of value of a sensor reading, reported in textual format. In several examples: a pulse counter might report 'Count', a current sensor might …
1.3.6.1.4.1.41542.3.3TablePOEXSensorInfoBySensorIDTablenot-accessiblemandatoryThe (conceptual) table containing sensor information in a legacy untranslated numeric format, addressed by sensor ID. This is provided for users who need a pre…
1.3.6.1.4.1.41542.3.3.1RowPOEXSensorInfoBySensorIDEntrynot-accessiblemandatoryAn entry (conceptual row) in the untranslated by-sensor-ID-order table containing the latest sensor state for a single sensor.
1.3.6.1.4.1.41542.3.3.1.1ColumnPOEXSensorInfoBySensorIDSensorDeviceIDread-onlymandatoryThe serial number identifier of the sensor device assigned and programmed by the manufacturer. This will ordinarily be printed on a label on the housing of the…
1.3.6.1.4.1.41542.3.3.1.2ColumnPOEXSensorInfoBySensorIDSensorDeviceWDIndexNoread-onlymandatoryThe index number of the sensor in the gateway's sensor registration table. This is the number used in referencing the sensor in the POEXSensorInfoBySensorRegis…
1.3.6.1.4.1.41542.3.3.1.3ColumnPOEXSensorInfoBySensorIDSensorDeviceTypeNoread-onlymandatoryThe manufacturer's type number that identifies the kind of sensor.
1.3.6.1.4.1.41542.3.3.1.4ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingAgeread-onlymandatoryThe age of the sensor report received most recently from a sensor. That time is reported as the number of seconds between the time of the sensor report and the…
1.3.6.1.4.1.41542.3.3.1.5ColumnPOEXSensorInfoBySensorIDSensorDeviceActiveread-onlymandatoryEither 1 (active) or 0 (inactive). A sensor will be reported active if it has recently communicated with the gateway since the last reboot. If a sensor device …
1.3.6.1.4.1.41542.3.3.1.6ColumnPOEXSensorInfoBySensorIDSensorDeviceAlarmingread-onlymandatoryEither 1 (alarming) or 0 (not alarming)'. A device will report an alarm if it is programmed with a threshold found to be exceeded. Examples: a temperature sens…
1.3.6.1.4.1.41542.3.3.1.7ColumnPOEXSensorInfoBySensorIDSensorDeviceVoltageread-onlymandatoryA value representing the voltage of the supply powering a sensor device. Ordinarily this will report the voltage at the battery terminals of a sensor. It is pr…
1.3.6.1.4.1.41542.3.3.1.8ColumnPOEXSensorInfoBySensorIDSensorDeviceRFStrengthread-onlymandatoryThe signal strength, in percent, of the radio link between the gateway and the particular sensor, as measured at the time of the most recent sensor report.
1.3.6.1.4.1.41542.3.3.1.9ColumnPOEXSensorInfoBySensorIDSensorDeviceRptUTread-onlymandatoryThe untranslated data block received from a sensor, in hexadecimal format. This may be used where a translating function isn't yet present, and for development…
1.3.6.1.4.1.41542.3.3.1.10ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue1read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.3.1.11ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue2read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.3.1.12ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue3read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.3.1.13ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue4read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.3.1.14ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue5read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.3.1.15ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue6read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.3.1.16ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue7read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.3.1.17ColumnPOEXSensorInfoBySensorIDSensorDeviceReadingValue8read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4TablePOEXSensorInfoBySensorRegisOrderTablenot-accessiblemandatoryThe (conceptual) table containing an untranslated numeric format, addressed by sensor registration order starting at 1 and ascending by one, in a legacy intege…
1.3.6.1.4.1.41542.3.4.1RowPOEXSensorInfoBySensorRegisOrderEntrynot-accessiblemandatoryAn entry (conceptual row) in the untranslated by-registration-order table containing the latest sensor state for a single sensor.
1.3.6.1.4.1.41542.3.4.1.1ColumnPOEXSensorInfoBySensorRegisOrderSensDevIDread-onlymandatoryThe serial number identifier of the sensor device assigned and programmed by the manufacturer. This will ordinarily be printed on a label on the housing of the…
1.3.6.1.4.1.41542.3.4.1.2ColumnPOEXSensorInfoBySensorRegisOrderSensDevWDIndexNoread-onlymandatoryThe index number of the sensor in the gateway's sensor registration table. This is the number used in referencing the sensor in the POEXSensorInfoBySensorRegis…
1.3.6.1.4.1.41542.3.4.1.3ColumnPOEXSensorInfoBySensorRegisOrderSensDevTypeNoread-onlymandatoryThe manufacturer's type number that identifies the kind of sensor.
1.3.6.1.4.1.41542.3.4.1.4ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingAgeread-onlymandatoryThe age of the sensor report received most recently from a sensor. That time is reported as the number of seconds between the time of the sensor report and the…
1.3.6.1.4.1.41542.3.4.1.5ColumnPOEXSensorInfoBySensorRegisOrderSensDevActiveread-onlymandatoryEither 1 (active) or 0 (inactive). A sensor will be reported active if it has recently communicated with the gateway since the last reboot. If a sensor device …
1.3.6.1.4.1.41542.3.4.1.6ColumnPOEXSensorInfoBySensorRegisOrderSensDevAlarmingread-onlymandatoryEither 1 (alarming) or 0 (not alarming)'. A device will report an alarm if it is programmed with a threshold found to be exceeded. Examples: a temperature sens…
1.3.6.1.4.1.41542.3.4.1.7ColumnPOEXSensorInfoBySensorRegisOrderSensDevVoltageread-onlymandatoryA value representing the voltage of the supply powering a sensor device. Ordinarily this will report the voltage at the battery terminals of a sensor. It is pr…
1.3.6.1.4.1.41542.3.4.1.8ColumnPOEXSensorInfoBySensorRegisOrderSensDevRFStrengthread-onlymandatoryThe signal strength, in percent, of the radio link between the gateway and the particular sensor, as measured at the time of the most recent sensor report.
1.3.6.1.4.1.41542.3.4.1.9ColumnPOEXSensorInfoBySensorRegisOrderSensDevRptUTread-onlymandatoryThe untranslated data block received from a sensor, in hexadecimal format. This may be used where a translating function isn't yet present, and for development…
1.3.6.1.4.1.41542.3.4.1.10ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl1read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4.1.11ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl2read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4.1.12ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl3read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4.1.13ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl4read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4.1.14ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl5read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4.1.15ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl6read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4.1.16ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl7read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
1.3.6.1.4.1.41542.3.4.1.17ColumnPOEXSensorInfoBySensorRegisOrderSensDevReadingVl8read-onlymandatoryThe value of a single sensor reading, or one half of a 64-bit reading, in integer format, not translated to human-readable form. See POEXSensorDeviceReadingU32…
Type Definitions
NameSyntaxStatusDescription
POEXDatumNoINTEGER(1..8)mandatoryThe datum number of a sequence of data readings from a sensor. The range of this type depends upon the number of datums reported by a sensor device. Thus, a 3-axis accelerometer sensor might report three datums for the …
POEXDatumNumberINTEGERmandatoryThe number of a datum in a set of datums comprising a sensor reading. For sensors reporting one datum, this will always be one. Otherwise it will be a number between 1 and the number of datums reported by the particular…
POEXSensorDeviceReadingAgeUnsigned32mandatoryThe age of the sensor report received most recently from a sensor. That time is reported as the number of seconds between the time of the sensor report and the time this information is requested.
POEXSensorDeviceReadingAlarmingOCTET STRINGmandatoryEither 'Alarming' or 'Not alarming'. A device will report an alarm if it is programmed with a threshold found to be exceeded. Examples: a temperature sensor for a refrigeration unit can be programmed to alarm if the mea…
POEXSensorDeviceReadingTranslatedUnitsOCTET STRINGmandatoryThe units or scale of value of a sensor reading, reported in textual format. In several examples: a pulse counter might report 'Count', a current sensor might report 'A', and a door sensor might report 'Closed'.
POEXSensorDeviceReadingTranslatedValueOCTET STRINGmandatoryThe value of a sensor reading, in textual format, translated according to sensor and datum types. These formats can include integers, fixed-point, and binary values. In several examples: a pulse counter might report '12…
POEXSensorDeviceReadingU32ValueUnsigned32mandatoryEither a single sensor value of up to 32 bits, or half of a 64-bit value. Thus where a sensor value is reportable in a single Unsigned32, one OID is sufficient to gather that value. Where more than 32 bits are needed, t…
POEXSensorDeviceReadingUnitsAllOCTET STRINGmandatoryAll of the units corresponding to the datums for the most recent reading of the sensor device, separated by commas, in textual format. For example, for a sensor reporting temperature and humidity this might read 'degree…
POEXSensorDeviceReadingUntranslatedOCTET STRINGmandatoryThe untranslated data block received from a sensor, in hexadecimal format. This may be used where a translating function isn't yet present, and for development purposes. Most users should use the translated values deliv…
POEXSensorDeviceReadingValuesAllOCTET STRINGmandatoryAll of the datums for the most recent reading of the sensor device, separated by commas, in textual format. For example, a report for a temperature and humidity sensor might read '20.3, 35' indicating 20.3 degrees at 35…
POEXSensorDeviceTypeOCTET STRINGmandatoryThe textual description of the type of the sensor device.
POEXSensorIDUnsigned32mandatoryThe serial number identifier of the sensor device assigned and programmed by the manufacturer. This will ordinarily be printed on a label on the housing of the device.
POEXSensorRegistrationIndexINTEGER(0..255)mandatoryThe index number of a sensor device in a gateway's sensor registration list. This is determined by the order in which a set of sensors has been registered, but will not change so long as the list remains fixed. This is …
POEXTrapAgeReportedOCTET STRINGmandatoryThe age of the sensor report received most recently from a sensor. That time is reported as the number of seconds between the time of the sensor report and the time this information is requested. POEXTrapAgeReported is …
POEXTrapAlarmingReportedOCTET STRING POEXNewSensorTraffic TRAP-TYPE ENTERPRISE POEX VARIABLES { POEXSensorInfoTranslatedFormatSensorDeviceID, POEXTrapDevIDReported, POEXSensorInfoTranslatedFormatSensorDeviceReadingValuesAll, POEXTrapAllValuesReported, POEXSensorInfoTranslatedFormatSensorDeviceReadingUnitsAll, POEXTrapAllUnitsReported, POEXSensorInfoTranslatedFormatSensorDeviceReadingAge, POEXTrapAgeReported, POEXSensorInfoTranslatedFormatSensorDeviceAlarming, POEXTrapAlarmingReported } DESCRIPTION "This trap, when enabled, will generate a report corresponding to new data from any registered sensor as it is received. Included with the trap message are the sensor ID, all values the sensor reports, units for all those values, the age, and whether the sensor is alarming." ::= 1 POEXDeviceAlarming TRAP-TYPE ENTERPRISE POEX VARIABLES { POEXSensorInfoTranslatedFormatSensorDeviceID, POEXTrapDevIDReported, POEXSensorInfoTranslatedFormatSensorDeviceReadingValuesAll, POEXTrapAllValuesReported, POEXSensorInfoTranslatedFormatSensorDeviceReadingUnitsAll, POEXTrapAllUnitsReported, POEXSensorInfoTranslatedFormatSensorDeviceReadingAge, POEXTrapAgeReported, POEXSensorInfoTranslatedFormatSensorDeviceAlarming, POEXTrapAlarmingReported } DESCRIPTION "This trap, when enabled, will generate a report corresponding to new data from any registered sensor as it is received, but only if that sensor is alarming and the POEXNewSensorTraffic trap is disabled. (That trap will generate the same message, rendering this trap redundant.) Included with the trap message are the sensor ID, all values the sensor reports, units for all those values, the age, and whether the sensor is alarming." ::= 2mandatoryEither 'Alarming' or 'Not alarming'. A device will report an alarm if it is programmed with a threshold found to be exceeded. Examples: a temperature sensor for a refrigeration unit can be programmed to alarm if the mea…
POEXTrapAllUnitsReportedOCTET STRINGmandatoryAll of the units corresponding to the datums for the most recent reading of the sensor device, separated by commas, in textual format. For example, for a sensor reporting temperature and humidity this might read 'degree…
POEXTrapAllValuesReportedOCTET STRINGmandatoryThis will make one of two reports. For the case the sensor type is known to the gateway, this will be all of the datums for the most recent reading of the sensor device, separated by commas, in textual format, using the…
POEXTrapDevIDReportedUnsigned32(1..2147483631)mandatoryThe serial number identifier of the sensor device assigned and programmed by the manufacturer. This will ordinarily be printed on a label on the housing of the device. POEXTrapDevIDReported is the same as POEXSensorID.