POSEIDON-MIB

54 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.21796Nodehwgroup
1.3.6.1.4.1.21796.3NodecharonII
1.3.6.1.4.1.21796.3.3Nodeposeidon
1.3.6.1.4.1.21796.3.3.1NodeinpAlarmStateChangedInput state entered/left alarm condition. This trap always follows tsTrapAlarmStart/tsTrapAlarmEnd.
1.3.6.1.4.1.21796.3.3.1TableinpTablenot-accessiblecurrentA list of binary input entries.
1.3.6.1.4.1.21796.3.3.1.1RowinpEntrynot-accessiblecurrentAn entry containing information applicable to a particular binary input.
1.3.6.1.4.1.21796.3.3.1.1.1ColumninpIndexnot-accessiblecurrentThe binary input index.
1.3.6.1.4.1.21796.3.3.1.1.2ColumninpValueread-onlycurrentThe binary input value.
1.3.6.1.4.1.21796.3.3.1.1.3ColumninpNameread-writecurrentThe binary input name.
1.3.6.1.4.1.21796.3.3.1.1.4ColumninpAlarmSetupread-writecurrentYou can enable alarm for this binary input. Alarm can be inactive or active for On/Off state.
1.3.6.1.4.1.21796.3.3.1.1.5ColumninpAlarmStateread-onlycurrentThe binary input alarm state.
1.3.6.1.4.1.21796.3.3.2TableoutTablenot-accessiblecurrentA list of binary output entries.
1.3.6.1.4.1.21796.3.3.2NodesensAlarmStateChangedNth sensor state entered/left alarm condition. This trap always follows tsTrapAlarmStart/tsTrapAlarmEnd.
1.3.6.1.4.1.21796.3.3.2.1RowoutEntrynot-accessiblecurrentAn entry containing information applicable to a particular binary output.
1.3.6.1.4.1.21796.3.3.2.1.1ColumnoutIndexnot-accessiblecurrentThe binary output index.
1.3.6.1.4.1.21796.3.3.2.1.2ColumnoutValueread-writecurrentThe binary output value. 0 off(open), 1 on(close)
1.3.6.1.4.1.21796.3.3.2.1.3ColumnoutNameread-writecurrentThe binary output name.
1.3.6.1.4.1.21796.3.3.2.1.4ColumnoutTyperead-onlycurrentThe binary output type. 0 relay (off, on), 1 rts (-10,+10V), 2 dtr (0,10V)
1.3.6.1.4.1.21796.3.3.2.1.5ColumnoutModeread-writecurrentThe binary output mode. 0 manual, 1 autoAlarm, 2 autoTriggerEq, 3 autoTriggerHi, 4 autoTriggerLo
1.3.6.1.4.1.21796.3.3.3TablesensTablenot-accessiblecurrentA list of sensor table entries. The number of entries corresponds with number of detected sensors.
1.3.6.1.4.1.21796.3.3.3NodetsTrapAlarmStartThis trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for powerFailure.
1.3.6.1.4.1.21796.3.3.3.1RowsensEntrynot-accessiblecurrentAn entry containing information applicable to a particular sensor.
1.3.6.1.4.1.21796.3.3.3.1.1ColumnsensIndexnot-accessiblecurrentThe sensor index.
1.3.6.1.4.1.21796.3.3.3.1.2ColumnsensNameread-onlycurrentThe sensor name.
1.3.6.1.4.1.21796.3.3.3.1.4ColumnsensStateread-onlycurrentThe sensor state.
1.3.6.1.4.1.21796.3.3.3.1.5ColumnsensStringread-onlycurrentThe string representation of sensor value.
1.3.6.1.4.1.21796.3.3.3.1.6ColumnsensValueread-onlycurrentThe integer (decimal * 10) representation of sensor value.
1.3.6.1.4.1.21796.3.3.3.1.7ColumnsensValueRawread-onlycurrentThe original raw value of sensor (it differs for each sensor type, especially 1-Wire sensors have different precisions).
1.3.6.1.4.1.21796.3.3.3.1.8ColumnsensIDread-onlycurrentThe sensor ID.
1.3.6.1.4.1.21796.3.3.3.1.9ColumnsensUnitread-onlycurrentThe sensor unit.
1.3.6.1.4.1.21796.3.3.3.1.10ColumnsensUnitStringread-onlycurrentThe string representation of sensor unit.
1.3.6.1.4.1.21796.3.3.4NodetsTrapAlarmEndThis trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms.
1.3.6.1.4.1.21796.3.3.50NodetsAlarm
1.3.6.1.4.1.21796.3.3.50.1ScalartsAlarmsPresentread-onlycurrentThe present number of active alarm conditions.
1.3.6.1.4.1.21796.3.3.50.2TabletsAlarmTablenot-accessiblecurrentA list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is …
1.3.6.1.4.1.21796.3.3.50.2.1RowtsAlarmEntrynot-accessiblecurrentAn entry containing information applicable to a particular alarm.
1.3.6.1.4.1.21796.3.3.50.2.1.1ColumntsAlarmIdxnot-accessiblecurrentAn index to alarm table.
1.3.6.1.4.1.21796.3.3.50.2.1.2ColumntsAlarmIdread-onlycurrentA unique identifier for an alarm condition. This value must remain constant.
1.3.6.1.4.1.21796.3.3.50.2.1.3ColumntsAlarmDescrread-onlycurrentDescription of the alarm condition.
1.3.6.1.4.1.21796.3.3.50.2.1.4ColumntsAlarmSensNameread-onlycurrentName of sensor with alarm condition.
1.3.6.1.4.1.21796.3.3.50.2.1.5ColumntsAlarmTimeread-onlycurrentThe value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before ag…
1.3.6.1.4.1.21796.3.3.70Nodeinfo
1.3.6.1.4.1.21796.3.3.70.1ScalarinfoAddressMACread-onlycurrentMAC address in text form. It is here to distinguish devices in trap messages.
1.3.6.1.4.1.21796.3.3.99Nodesetup
1.3.6.1.4.1.21796.3.3.99.1NodesensSetup
1.3.6.1.4.1.21796.3.3.99.1.1ScalarunitTyperead-writecurrentUnits for displayed values. All setup values are fixed in Celsius
1.3.6.1.4.1.21796.3.3.99.1.2TablesensSetupTablenot-accessiblecurrentA list of sensor table setup entries. The number of entries corresponds with number of detected sensors.
1.3.6.1.4.1.21796.3.3.99.1.2.1RowsensSetupEntrynot-accessiblecurrentAn entry containing setup information for a particular sensor.
1.3.6.1.4.1.21796.3.3.99.1.2.1.1ColumnsensSetupIndexnot-accessiblecurrentThe sensor setup table index.
1.3.6.1.4.1.21796.3.3.99.1.2.1.2ColumnsensSetupNameread-writecurrentThe sensor name.
1.3.6.1.4.1.21796.3.3.99.1.2.1.5ColumnsensFlagsread-writecurrentThe behaviour of sensor - 0x01: range or level detection - 0x02: enable trap sending - 0x08: sensor enabled - 0x10: enable SMS sending - 0x20: enable email sen…
1.3.6.1.4.1.21796.3.3.99.1.2.1.6ColumnsensLimitMinread-writecurrentThe sensor low limit.
1.3.6.1.4.1.21796.3.3.99.1.2.1.7ColumnsensLimitMaxread-writecurrentThe sensor high limit.
1.3.6.1.4.1.21796.3.3.99.1.2.1.8ColumnsensHysteresisread-writecurrentThe sensor hysteresis.