MIB Viewer

PRIVATE-FEL2Mod-SW24-MIB

215 objects
The MIB module is for xxx Tech.
Imported Objects
RFC1213-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter32 enterprises IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.5205IdentityprivatetechThe MIB module is for xxx Tech.
1.3.6.1.4.1.5205.2Nodeswitch
1.3.6.1.4.1.5205.2.19NodefeL2ModSW24ProductID
1.3.6.1.4.1.5205.2.19.1NodefeL2ModSW24Produces
1.3.6.1.4.1.5205.2.19.1.1NodefeL2ModSW24System
1.3.6.1.4.1.5205.2.19.1.1.1NodefeL2ModSW24CommonSys
1.3.6.1.4.1.5205.2.19.1.1.1.1ScalarfeL2ModSW24Rebootread-writecurrentReboot the system. Get this OID always return zero. 0 - do nothing 1 - Reboot without saving start 2 - Reboot with saving start
1.3.6.1.4.1.5205.2.19.1.1.1.2ScalarfeL2ModSW24BiosVsersionread-onlycurrentGet the BIOS version of the system.
1.3.6.1.4.1.5205.2.19.1.1.1.3ScalarfeL2ModSW24FirmwareVersionread-onlycurrentGet the firmware version of the system.
1.3.6.1.4.1.5205.2.19.1.1.1.4ScalarfeL2ModSW24HardwareVersionread-onlycurrentGet the hardware version of the system.
1.3.6.1.4.1.5205.2.19.1.1.1.5ScalarfeL2ModSW24MechanicalVersionread-onlycurrentGet the mechanical version of the system.
1.3.6.1.4.1.5205.2.19.1.1.1.6ScalarfeL2ModSW24SerialNumberread-onlycurrentGet the Serial number of the system.
1.3.6.1.4.1.5205.2.19.1.1.1.7ScalarfeL2ModSW24HostMacAddressread-onlycurrentGet the MAC address of the system.
1.3.6.1.4.1.5205.2.19.1.1.1.8ScalarfeL2ModSW24DevicePortread-onlycurrentGet the quantity of ports that this system owns now.
1.3.6.1.4.1.5205.2.19.1.1.1.9ScalarfeL2ModSW24RamSizeread-onlycurrentGet the RAM size of the system.
1.3.6.1.4.1.5205.2.19.1.1.1.10ScalarfeL2ModSW24FlashSizeread-onlycurrentGet the flash size of the system.
1.3.6.1.4.1.5205.2.19.1.1.2NodefeL2ModSW24IP
1.3.6.1.4.1.5205.2.19.1.1.2.1ScalarfeL2ModSW24DhcpSettingread-writecurrentGet/Set DHCP status of the system. 0 - DHCP disable 1 - DHCP enable
1.3.6.1.4.1.5205.2.19.1.1.2.2ScalarfeL2ModSW24IPAddressread-writecurrentGet/Set the IP address of the system. You can't set this OID if DHCP status is enabled.
1.3.6.1.4.1.5205.2.19.1.1.2.3ScalarfeL2ModSW24NetMaskread-writecurrentGet/Set the subnet mask of the system. You can't set this OID if DHCP status is enabled.
1.3.6.1.4.1.5205.2.19.1.1.2.4ScalarfeL2ModSW24DefaultGatewayread-writecurrentGet/Set the default gateway of the system. You can't set this OID if DHCP status is enabled.
1.3.6.1.4.1.5205.2.19.1.1.2.5ScalarfeL2ModSW24DnsSettingread-writecurrentGet/Set the source of DNS server. You can't set this OID if DHCP status is disabled. 0 - manual, the DNS server is from manual setting 1 - auto, the DNS server…
1.3.6.1.4.1.5205.2.19.1.1.2.6ScalarfeL2ModSW24DnsServerread-writecurrentGet/Set the DNS server of the system.
1.3.6.1.4.1.5205.2.19.1.1.3NodefeL2ModSW24Time
1.3.6.1.4.1.5205.2.19.1.1.3.1ScalarfeL2ModSW24SystemCurrentTimeread-onlycurrentGet the current time of the system.
1.3.6.1.4.1.5205.2.19.1.1.3.2ScalarfeL2ModSW24ManualTimeSettingread-writecurrentGet/Set the system time of the device. The input format is 'Year/Month/Day/Hour/Minute/Second'. ex: 2004/1/1/12/34/25 means 2004/1/1 - 12:24:25 . The value ran…
1.3.6.1.4.1.5205.2.19.1.1.3.3ScalarfeL2ModSW24NTPServerread-writecurrentGet/Set the NTP Time Server. You can use the IP address or domain name.
1.3.6.1.4.1.5205.2.19.1.1.3.4ScalarfeL2ModSW24NTPTimeZoneread-writecurrentGet/Set the NTP Time Zone. The value range is between -12 and 13 -12 - GMT -12:00, -11 - GMT -11:00, -10 - GMT -10:00, -9 - GMT -09:00, -8 - GMT -08:00, -7 - G…
1.3.6.1.4.1.5205.2.19.1.1.3.5ScalarfeL2ModSW24NTPTimeSyncread-writecurrentSync time from NTP Server. Get this OID always return zero. Set the Time Server and Time Zone before doing time sync. Notice that time server must be correct! …
1.3.6.1.4.1.5205.2.19.1.1.3.6ScalarfeL2ModSW24DaylightSavingTimeread-writecurrentGet/Set the daylight saving time. The value range is between -5 and 5. (Unit: hour)
1.3.6.1.4.1.5205.2.19.1.1.3.7ScalarfeL2ModSW24DaylightStartTimeread-writecurrentGet/Set the Start time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. example: month/day/hour 10/01…
1.3.6.1.4.1.5205.2.19.1.1.3.8ScalarfeL2ModSW24DaylightEndTimeread-writecurrentGet/Set the End time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. example: month/day/hour 04/01/0…
1.3.6.1.4.1.5205.2.19.1.1.4NodefeL2ModSW24Account
1.3.6.1.4.1.5205.2.19.1.1.4.1ScalarfeL2ModSW24AccountNumberread-onlycurrentGet the current account number(s) of the system.
1.3.6.1.4.1.5205.2.19.1.1.4.2TablefeL2ModSW24AccountTablenot-accessiblecurrentThis is a list of FEL2ModSW24AccountEntry. The numbers of entries are given by the value of feL2ModSW24AccountNumber.
1.3.6.1.4.1.5205.2.19.1.1.4.2.1RowfeL2ModSW24AccountEntrynot-accessiblecurrentThis is the Entry(s) for account information.
1.3.6.1.4.1.5205.2.19.1.1.4.2.1.1ColumnfeL2ModSW24AccountIndexread-onlycurrentThis is the index of the account entry.
1.3.6.1.4.1.5205.2.19.1.1.4.2.1.2ColumnfeL2ModSW24AccountAuthorizationread-onlycurrentThis is the authorization of the account entry.
1.3.6.1.4.1.5205.2.19.1.1.4.2.1.3ColumnfeL2ModSW24AccountNameread-writecurrentThis is the username of the account entry.
1.3.6.1.4.1.5205.2.19.1.1.4.2.1.4ColumnfeL2ModSW24AccountPasswordread-writecurrentThis is the password of the account entry. The return value is always '********'.
1.3.6.1.4.1.5205.2.19.1.1.4.3ScalarfeL2ModSW24AccountAddNameread-writecurrentThis is the account name for adding operation.
1.3.6.1.4.1.5205.2.19.1.1.4.4ScalarfeL2ModSW24AccountAddPasswordread-writecurrentThis is the account password for adding operation. The return value is always '********'.
1.3.6.1.4.1.5205.2.19.1.1.4.5ScalarfeL2ModSW24DoAccountAddread-writecurrentAdd account name. OID feL2ModSW24AccountAddName and feL2ModSW24AccountAddPassword must be filled first. Get this OID always return zero. 1 - add account. 0 - d…
1.3.6.1.4.1.5205.2.19.1.1.4.6ScalarfeL2ModSW24AccountDelread-writecurrentDelete account. The value is valid feL2ModSW24AccountIndex(Can't delete administrator).
1.3.6.1.4.1.5205.2.19.1.2NodefeL2ModSW24Snmp
1.3.6.1.4.1.5205.2.19.1.2.1ScalarfeL2ModSW24GetCommunityread-writecurrentGet/Set the get-community of the SNMP.
1.3.6.1.4.1.5205.2.19.1.2.2ScalarfeL2ModSW24SetCommunityread-writecurrentGet/Set the set-community of the SNMP.
1.3.6.1.4.1.5205.2.19.1.2.3ScalarfeL2ModSW24TrapHostNumberread-onlycurrentGet the number of trap hosts.
1.3.6.1.4.1.5205.2.19.1.2.4TablefeL2ModSW24TrapHostTablenot-accessiblecurrentA list of trap host entry. The numbers of entries are given by the value of feL2ModSW24TrapHostNumber.
1.3.6.1.4.1.5205.2.19.1.2.4.1RowfeL2ModSW24TrapHostEntrynot-accessiblecurrentThis is the entry information for trap host.
1.3.6.1.4.1.5205.2.19.1.2.4.1.1ColumnfeL2ModSW24TrapHostIndexread-onlycurrentThe index of the trap host entry.
1.3.6.1.4.1.5205.2.19.1.2.4.1.2ColumnfeL2ModSW24TrapHostIPread-writecurrentThis is the IP of the trap host.
1.3.6.1.4.1.5205.2.19.1.2.4.1.3ColumnfeL2ModSW24TrapHostPortread-writecurrentThis is the receiving-port number of the trap host.
1.3.6.1.4.1.5205.2.19.1.2.4.1.4ColumnfeL2ModSW24TrapHostCommunityread-writecurrentThe community name for the trap PDU.
1.3.6.1.4.1.5205.2.19.1.3NodefeL2ModSW24Alarm
1.3.6.1.4.1.5205.2.19.1.3.1NodefeL2ModSW24Event
1.3.6.1.4.1.5205.2.19.1.3.1.1ScalarfeL2ModSW24EventNumberread-onlycurrentGet the total number of alarm events.
1.3.6.1.4.1.5205.2.19.1.3.1.2TablefeL2ModSW24EventTablenot-accessiblecurrentA list of alarm event entry. The numbers of entries are given by the value of feL2ModSW24EventNumber.
1.3.6.1.4.1.5205.2.19.1.3.1.2.1RowfeL2ModSW24EventEntrynot-accessiblecurrentThis is the entry information for alarm event.
1.3.6.1.4.1.5205.2.19.1.3.1.2.1.1ColumnfeL2ModSW24EventIndexread-onlycurrentThis is the index of the alarm event entry.
1.3.6.1.4.1.5205.2.19.1.3.1.2.1.2ColumnfeL2ModSW24EventNameread-onlycurrentThis is the alarm event name.
1.3.6.1.4.1.5205.2.19.1.3.1.2.1.3ColumnfeL2ModSW24EventSendEmailread-writecurrentSend email when alarm event is triggered.
1.3.6.1.4.1.5205.2.19.1.3.1.2.1.4ColumnfeL2ModSW24EventSendSMSread-writecurrentSend SMS when alarm event is triggered.
1.3.6.1.4.1.5205.2.19.1.3.1.2.1.5ColumnfeL2ModSW24EventSendTrapread-writecurrentSend trap when alarm event is triggered.
1.3.6.1.4.1.5205.2.19.1.3.2NodefeL2ModSW24Email
1.3.6.1.4.1.5205.2.19.1.3.2.1ScalarfeL2ModSW24EmailServerread-writecurrentThis is the SMTP server for alarm event.
1.3.6.1.4.1.5205.2.19.1.3.2.2ScalarfeL2ModSW24EmailUsernameread-writecurrentThis is the Username of SMTP server.
1.3.6.1.4.1.5205.2.19.1.3.2.3ScalarfeL2ModSW24EmailPasswordread-writecurrentThis is the User Password of SMTP server.
1.3.6.1.4.1.5205.2.19.1.3.2.4ScalarfeL2ModSW24EmailUserNumberread-onlycurrentThe number of the email users that you want to send the alarm notification.
1.3.6.1.4.1.5205.2.19.1.3.2.5TablefeL2ModSW24EmailUserTablenot-accessiblecurrentThis is a list of email user entry. The numbers of entries are given by the value of feL2ModSW24EmailUserNumber.
1.3.6.1.4.1.5205.2.19.1.3.2.5.1RowfeL2ModSW24EmailUserEntrynot-accessiblecurrentThis is the Entry information for email user entry.
1.3.6.1.4.1.5205.2.19.1.3.2.5.1.1ColumnfeL2ModSW24EmailUserIndexread-onlycurrentThis is the index of the email user entry.
1.3.6.1.4.1.5205.2.19.1.3.2.5.1.2ColumnfeL2ModSW24EmailUserAddressread-writecurrentThis is the email address of the email user entry.
1.3.6.1.4.1.5205.2.19.1.3.3NodefeL2ModSW24SMS
1.3.6.1.4.1.5205.2.19.1.3.3.1ScalarfeL2ModSW24SMSServerread-writecurrentThis is the SMS server for alarm event.
1.3.6.1.4.1.5205.2.19.1.3.3.2ScalarfeL2ModSW24SMSUsernameread-writecurrentThis is the Username of SMS server.
1.3.6.1.4.1.5205.2.19.1.3.3.3ScalarfeL2ModSW24SMSPasswordread-writecurrentThis is the Password of SMS server.
1.3.6.1.4.1.5205.2.19.1.3.3.4ScalarfeL2ModSW24SMSUserNumberread-onlycurrentThe number of the SMS users that you want to send the alarm notification.
1.3.6.1.4.1.5205.2.19.1.3.3.5TablefeL2ModSW24SMSUserTablenot-accessiblecurrentThis is a list of SMS user entry. The numbers of entries are given by the value of feL2ModSW24SMSUserNumber.
1.3.6.1.4.1.5205.2.19.1.3.3.5.1RowfeL2ModSW24SMSUserEntrynot-accessiblecurrentThis is the Entry information for SMS user entry.
1.3.6.1.4.1.5205.2.19.1.3.3.5.1.1ColumnfeL2ModSW24SMSUserIndexread-onlycurrentThis is the index of the SMS user entry.
1.3.6.1.4.1.5205.2.19.1.3.3.5.1.2ColumnfeL2ModSW24SMSUserMobilePhoneread-writecurrentThe SMS phone number of the SMS user entry.
1.3.6.1.4.1.5205.2.19.1.4NodefeL2ModSW24Tftp
1.3.6.1.4.1.5205.2.19.1.4.1ScalarfeL2ModSW24TftpServerread-writecurrentGet/Set the tftp server.
1.3.6.1.4.1.5205.2.19.1.5NodefeL2ModSW24Configuration
1.3.6.1.4.1.5205.2.19.1.5.1NodefeL2ModSW24SaveRestore
1.3.6.1.4.1.5205.2.19.1.5.1.1ScalarfeL2ModSW24SaveStartread-writecurrentSave current configuration into flash memory (Save as Start Configuration). Get this OID always return zero. 1 - save. 0 - do nothing.
1.3.6.1.4.1.5205.2.19.1.5.1.2ScalarfeL2ModSW24SaveUserread-writecurrentSave current configuration into flash memory (Save as User Configuration). Get this OID always return zero. 1 - save. 0 - do nothing.
1.3.6.1.4.1.5205.2.19.1.5.1.3ScalarfeL2ModSW24RestoreDefaultread-writecurrentRestore factory default configuration. Get this OID always return zero. 2 - restore default included default ip address. 1 - restore default without changing c…
1.3.6.1.4.1.5205.2.19.1.5.1.4ScalarfeL2ModSW24RestoreUserread-writecurrentRestore user configuration. Get this OID always return zero. 1 - restore. 0 - do nothing.
1.3.6.1.4.1.5205.2.19.1.5.2NodefeL2ModSW24ConfigFile
1.3.6.1.4.1.5205.2.19.1.5.2.1ScalarfeL2ModSW24ExportConfigNameread-writecurrentGet/Set the export file path and name.
1.3.6.1.4.1.5205.2.19.1.5.2.2ScalarfeL2ModSW24DoExportConfigread-writecurrentDo export-config. Get this oid always return zero. 1 - export start section. 2 - export user-conf section.
1.3.6.1.4.1.5205.2.19.1.5.2.3ScalarfeL2ModSW24ImportConfigNameread-writecurrentGet/Set the import file path and name.
1.3.6.1.4.1.5205.2.19.1.5.2.4ScalarfeL2ModSW24DoImportConfigread-writecurrentDo import-config. Get this OID always return zero. 1 - import start section. 2 - import user-conf section.
1.3.6.1.4.1.5205.2.19.1.6NodefeL2ModSW24Diagnostic
1.3.6.1.4.1.5205.2.19.1.6.1ScalarfeL2ModSW24EEPROMTestread-onlycurrentEEPROM access test.
1.3.6.1.4.1.5205.2.19.1.6.2ScalarfeL2ModSW24UartTestread-onlycurrentUART access test.
1.3.6.1.4.1.5205.2.19.1.6.3ScalarfeL2ModSW24DramTestread-onlycurrentDRAM access test.
1.3.6.1.4.1.5205.2.19.1.6.4ScalarfeL2ModSW24FlashTestread-onlycurrentFlash memory access test.
1.3.6.1.4.1.5205.2.19.1.6.5ScalarfeL2ModSW24InternalLoopbackTestread-onlycurrentInternal loopback test.
1.3.6.1.4.1.5205.2.19.1.6.6ScalarfeL2ModSW24ExternalLoopbackTestread-onlycurrentExternal loopback test.
1.3.6.1.4.1.5205.2.19.1.6.7ScalarfeL2ModSW24PingTestread-writecurrentSet the host address that you want to ping and the system will return the test result.
1.3.6.1.4.1.5205.2.19.1.7NodefeL2ModSW24Log
1.3.6.1.4.1.5205.2.19.1.7.1ScalarfeL2ModSW24ClearLogread-writecurrentClear system log. Get this OID always return zero. 1 - clear log. 0 - do nothing.
1.3.6.1.4.1.5205.2.19.1.7.2ScalarfeL2ModSW24UploadLogread-writecurrentUpload current system log. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return zero.…
1.3.6.1.4.1.5205.2.19.1.7.3ScalarfeL2ModSW24AutoUploadLogStateread-writecurrentEnable auto-upload log function. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return…
1.3.6.1.4.1.5205.2.19.1.7.4ScalarfeL2ModSW24LogNumberread-onlycurrentGet the number of current system log.
1.3.6.1.4.1.5205.2.19.1.7.5TablefeL2ModSW24LogTablenot-accessiblecurrentThis is a list of log entry. The numbers of entries are given by the value of feL2ModSW24LogNumber.
1.3.6.1.4.1.5205.2.19.1.7.5.1RowfeL2ModSW24LogEntrynot-accessiblecurrentThis is the Entry information for system log.
1.3.6.1.4.1.5205.2.19.1.7.5.1.1ColumnfeL2ModSW24LogIndexread-onlycurrentThis is the index of the log entry.
1.3.6.1.4.1.5205.2.19.1.7.5.1.2ColumnfeL2ModSW24LogEventread-onlycurrentThis is the detail information of the log entry.
1.3.6.1.4.1.5205.2.19.1.8NodefeL2ModSW24Firmware
1.3.6.1.4.1.5205.2.19.1.8.1ScalarfeL2ModSW24FirmwareFileNameread-writecurrentGet/Set the path and filename for firmware upgrading.
1.3.6.1.4.1.5205.2.19.1.8.2ScalarfeL2ModSW24DoFirmwareUpgraderead-writecurrentDo firmware upgrade. Get this OID always return zero. 1 - do firmware upgrade. 0 - do nothing.
1.3.6.1.4.1.5205.2.19.1.9NodefeL2ModSW24Port
1.3.6.1.4.1.5205.2.19.1.9.1NodefeL2ModSW24PortStatus
1.3.6.1.4.1.5205.2.19.1.9.1.1ScalarfeL2ModSW24PortStatusNumberread-onlycurrentGet the number of port.
1.3.6.1.4.1.5205.2.19.1.9.1.2TablefeL2ModSW24PortStatusTablenot-accessiblecurrentThis is a list of port status entry. The numbers of entries are given by the value of feL2ModSW24PortStatusNumber.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1RowfeL2ModSW24PortStatusEntrynot-accessiblecurrentThis is the entry(s) for port status information.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.1ColumnfeL2ModSW24PortStatusIndexread-onlycurrentThis is the index of the port status entry.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.2ColumnfeL2ModSW24PortStatusMediaread-onlycurrentThe port media type of the port status entry.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.3ColumnfeL2ModSW24PortStatusLinkread-onlycurrentThis is the port link of the port status entry.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.4ColumnfeL2ModSW24PortStatusPortStateread-onlycurrentThis is the port state of the port status entry.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.5ColumnfeL2ModSW24PortStatusAutoNegoread-onlycurrentThis is the auto negotiation of the port status entry.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.6ColumnfeL2ModSW24PortStatusSpdDpxread-onlycurrentThis is the speed/duplex of the port status entry.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.7ColumnfeL2ModSW24PortStatusFlwCtrlread-onlycurrentThis is the flow control of the port status entry.
1.3.6.1.4.1.5205.2.19.1.9.1.2.1.8ColumnfeL2ModSW24PortStatuDescriptionread-onlycurrentThe description of port.
1.3.6.1.4.1.5205.2.19.1.9.2NodefeL2ModSW24PortConf
1.3.6.1.4.1.5205.2.19.1.9.2.1ScalarfeL2ModSW24PortConfNumberread-onlycurrentGet the number of port configuration.
1.3.6.1.4.1.5205.2.19.1.9.2.2TablefeL2ModSW24PortConfTablenot-accessiblecurrentThis is a list of port configuration entry. The numbers of entries are given by the value of feL2ModSW24PortConfNumber.
1.3.6.1.4.1.5205.2.19.1.9.2.2.1RowfeL2ModSW24PortConfEntrynot-accessiblecurrentThis is the Entry(s) for port configuration information.
1.3.6.1.4.1.5205.2.19.1.9.2.2.1.1ColumnfeL2ModSW24PortConfIndexread-onlycurrentThis is the index of the port configuration entry.
1.3.6.1.4.1.5205.2.19.1.9.2.2.1.2ColumnfeL2ModSW24PortConfPortStateread-writecurrentThis is the port state of the port configuration entry. 0 - disabled. 1 - enabled.
1.3.6.1.4.1.5205.2.19.1.9.2.2.1.3ColumnfeL2ModSW24PortConfSpdDpxread-writecurrentThis is the speed/duplex of the port configuration entry. 0 - auto. 1 - 10M/Half. 2 - 10M/Full. 3 - 100M/Half. 4 - 100M/Full. 5 - 1G/Full.
1.3.6.1.4.1.5205.2.19.1.9.2.2.1.4ColumnfeL2ModSW24PortConfFlwCtrlread-writecurrentThis is the flow control of the port configuration entry. 0 - disabled. 1 - enabled.
1.3.6.1.4.1.5205.2.19.1.9.2.2.1.5ColumnfeL2ModSW24PortConfDescriptionread-writecurrentThe description of port.
1.3.6.1.4.1.5205.2.19.1.10NodefeL2ModSW24Mirror
1.3.6.1.4.1.5205.2.19.1.10.1ScalarfeL2ModSW24MirrorModeread-writecurrentGet/Set the Mirror mode. 0 - disabled. 1 - rx enable.
1.3.6.1.4.1.5205.2.19.1.10.2ScalarfeL2ModSW24MirroringPortread-writecurrentGet/Set the mirroring port. The port range is from 1 to 24.
1.3.6.1.4.1.5205.2.19.1.10.3ScalarfeL2ModSW24MirroredPortsread-writecurrentGet/Set the monitored ports. The port range is from 1 to 24, and the syntax is 1,5-7.
1.3.6.1.4.1.5205.2.19.1.11NodefeL2ModSW24MaxPktLen
1.3.6.1.4.1.5205.2.19.1.11.1NodefeL2ModSW24MaxPktLen1
1.3.6.1.4.1.5205.2.19.1.11.1.1ScalarfeL2ModSW24MaxPktLenPortNumberread-onlycurrentGet the number of Max. packet length.
1.3.6.1.4.1.5205.2.19.1.11.1.2TablefeL2ModSW24MaxPktLenConfTablenot-accessiblecurrentThis is a list of Max. packet length entry. The numbers of entries are given by the value of feL2ModSW24MaxPktLenPortNumber.
1.3.6.1.4.1.5205.2.19.1.11.1.2.1RowfeL2ModSW24MaxPktLenConfEntrynot-accessiblecurrentEntry(s) for Max. packet length information.
1.3.6.1.4.1.5205.2.19.1.11.1.2.1.1ColumnfeL2ModSW24MaxPktLenConfIndexread-onlycurrentThis is the index of the Max. packet length entry.
1.3.6.1.4.1.5205.2.19.1.11.1.2.1.2ColumnfeL2ModSW24MaxPktLenConfSettingread-writecurrentGet/Set the Max. packet length. The Max. packet length is 1518,1532,or 9216.
1.3.6.1.4.1.5205.2.19.1.12NodefeL2ModSW24Bandwidth
1.3.6.1.4.1.5205.2.19.1.12.1NodefeL2ModSW24Bandwidth1
1.3.6.1.4.1.5205.2.19.1.12.1.1ScalarfeL2ModSW24BandwidthPortNumberread-onlycurrentGet the number of bandwidth management configuration.
1.3.6.1.4.1.5205.2.19.1.12.1.2TablefeL2ModSW24BandwidthConfTablenot-accessiblecurrentA list of bandwidth management configuration entry. The numbers of entries are given by the value of feL2ModSW24BandwidthPortNumber.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1RowfeL2ModSW24BandwidthConfEntrynot-accessiblecurrentThis is the Entry(s) for bandwidth management configuration information.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1.1ColumnfeL2ModSW24BandwidthConfIndexread-onlycurrentThis is the index of the bandwidth management configuration entry.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1.2ColumnfeL2ModSW24BandwidthConfIngressStateread-writecurrentThe ingress state of the bandwidth management configures entry. 0 - disabled. 1 - enabled.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1.3ColumnfeL2ModSW24BandwidthConfIngressBWread-writecurrentGet/Set the ingress rate of the bandwidth management configuration. The ingress rate is from 0 to 1000.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1.4ColumnfeL2ModSW24BandwidthConfStormStateread-writecurrentThe storm state of the bandwidth management configuration entry. 0 - disabled. 1 - enabled.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1.5ColumnfeL2ModSW24BandwidthConfStormBWread-writecurrentGet/Set the storm rate of the bandwidth management configuration. The storm rate is from 0 to 1000.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1.6ColumnfeL2ModSW24BandwidthConfEgressStateread-writecurrentThe egress state of the bandwidth management configuration entry. 0 - disabled. 1 - enabled.
1.3.6.1.4.1.5205.2.19.1.12.1.2.1.7ColumnfeL2ModSW24BandwidthConfEgressBWread-writecurrentGet/Set the egress rate of the bandwidth management configuration. The egress rate is from 0 to 1000.
1.3.6.1.4.1.5205.2.19.1.13NodefeL2ModSW24LoopDetectedConf
1.3.6.1.4.1.5205.2.19.1.13.1ScalarfeL2ModSW24LoopDetectedNumberread-onlycurrentGet the number of loop detected entry.
1.3.6.1.4.1.5205.2.19.1.13.2TablefeL2ModSW24LoopDetectedTablenot-accessiblecurrentA list of loop detected entry. The numbers of entries are given by the value of feL2ModSW24LoopDetectedNumber.
1.3.6.1.4.1.5205.2.19.1.13.2.1RowfeL2ModSW24LoopDetectedEntrynot-accessiblecurrentEntry(s) for loop detected information.
1.3.6.1.4.1.5205.2.19.1.13.2.1.1ColumnfeL2ModSW24LoopDetectedfIndexread-onlycurrentThe index of the loop detected entry.
1.3.6.1.4.1.5205.2.19.1.13.2.1.2ColumnfeL2ModSW24LoopDetectedStateEblread-writecurrentThe state of the loop detected entry. 0 - disabled. 1 - enabled.
1.3.6.1.4.1.5205.2.19.1.13.2.1.3ColumnfeL2ModSW24LoopDetectedCurrentStatusread-onlycurrentThe current status of the loop detected port. 0 - unlocked 1 - locked due to the loop condition
1.3.6.1.4.1.5205.2.19.1.13.2.1.4ColumnfeL2ModSW24LoopDetectedResumedread-writecurrentUnlock the port which is locked due to loop condition. Get this OID always return zero. 1 - unlock the port, 0 - do nothing.
1.3.6.1.4.1.5205.2.19.1.13.3ScalarfeL2ModSW24LoopDetectedActionread-writecurrentSet the corresponding action while loop is detected. 1 - lock the loop port, 0 - do nothing.
1.3.6.1.4.1.5205.2.19.1.14NodefeL2ModSW24SFPInfo
1.3.6.1.4.1.5205.2.19.1.14.1ScalarfeL2ModSW24SFPInfoNumberread-onlycurrentGet the number of sfp info entry.
1.3.6.1.4.1.5205.2.19.1.14.2TablefeL2ModSW24SFPInfoTablenot-accessiblecurrentA list of sfp info entry. The numbers of entries are given by the value of feL2ModSW24SFPInfoNumber.
1.3.6.1.4.1.5205.2.19.1.14.2.1RowfeL2ModSW24SFPInfoEntrynot-accessiblecurrentEntry(s) for SFP information.
1.3.6.1.4.1.5205.2.19.1.14.2.1.1ColumnfeL2ModSW24SFPInfoIndexread-onlycurrentThe index of the sfp info entry.
1.3.6.1.4.1.5205.2.19.1.14.2.1.2ColumnfeL2ModSW24SFPConnectorTyperead-onlycurrentGet connector type of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.3ColumnfeL2ModSW24SFPFiberTyperead-onlycurrentGet fiber type of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.4ColumnfeL2ModSW24SFPWavelengthread-onlycurrentGet tx central wavelength of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.5ColumnfeL2ModSW24SFPBaudRateread-onlycurrentGet baud rate of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.6ColumnfeL2ModSW24SFPVendorOUIread-onlycurrentGet vendor OUI of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.7ColumnfeL2ModSW24SFPVendorNameread-onlycurrentGet vendor name of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.8ColumnfeL2ModSW24SFPVendorPNread-onlycurrentGet vendor part number of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.9ColumnfeL2ModSW24SFPVendorRevread-onlycurrentGet vendor revision number of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.10ColumnfeL2ModSW24SFPVendorSNread-onlycurrentGet vendor serial number of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.11ColumnfeL2ModSW24SFPDateCoderead-onlycurrentGet data code of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.12ColumnfeL2ModSW24SFPTemperatureread-onlycurrentGet current temperature of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.13ColumnfeL2ModSW24SFPVccread-onlycurrentGet current internal supply voltage of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.14ColumnfeL2ModSW24SFPTxBiasread-onlycurrentGet current TX Bias of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.15ColumnfeL2ModSW24SFPTxPWRread-onlycurrentGet current TX output power of the sfp.
1.3.6.1.4.1.5205.2.19.1.14.2.1.16ColumnfeL2ModSW24SFPRxPWRread-onlycurrentGet current Received Power of the sfp.
1.3.6.1.4.1.5205.2.19.1.20NodefeL2ModSW24TrapEntry
1.3.6.1.4.1.5205.2.19.1.20.1NotificationfeL2ModSW24ModuleInsertedcurrentSend the trap when a module is inserted to the system. The OID value means the port number.
1.3.6.1.4.1.5205.2.19.1.20.2NotificationfeL2ModSW24ModuleRemovedcurrentSend the trap when a module is removed from the system. The OID value means the port number.
1.3.6.1.4.1.5205.2.19.1.20.5NotificationfeL2ModSW24LoopDetectedcurrentSend the trap when loop condition has been detected. The OID value means the port number.
1.3.6.1.4.1.5205.2.19.1.20.100NotificationfeL2ModSW24StpStateDisabledcurrentSend the trap when the operational state of STP is from enabled to disabled.
1.3.6.1.4.1.5205.2.19.1.20.101NotificationfeL2ModSW24StpStateEnabledcurrentSend the trap when the operational state of STP is from disabled to enabled.
1.3.6.1.4.1.5205.2.19.1.20.102NotificationfeL2ModSW24StpTopologyChangedcurrentSend the trap when RSTP determines a port should enter the FORWARDING state (a topology change occurs). The OID value is the ifIndex of the port that produces …
1.3.6.1.4.1.5205.2.19.1.20.120NotificationfeL2ModSW24LacpStateDisabledcurrentSend the trap when the operational state of LACP is from enabled to disabled. The OID value means the disabled Group ID.
1.3.6.1.4.1.5205.2.19.1.20.121NotificationfeL2ModSW24LacpStateEnabledcurrentSend the trap when the operational state of LACP is from disabled to enabled. The OID value means the disabled Group ID.
1.3.6.1.4.1.5205.2.19.1.20.123NotificationfeL2ModSW24LacpPortAddedcurrentSend the trap when the state of port is in 'trunk ready'.
1.3.6.1.4.1.5205.2.19.1.20.124NotificationfeL2ModSW24LacpPortTrunkFailurecurrentSend the trap when one port is not able to be aggregated due to duplex-mode of the port.
1.3.6.1.4.1.5205.2.19.1.20.140NotificationfeL2ModSW24GvrpStateDisabledcurrentSend the trap when the operational state of GVRP is from enabled to disabled.
1.3.6.1.4.1.5205.2.19.1.20.141NotificationfeL2ModSW24GvrpStateEnabledcurrentSend the trap when the operational state of LACP is from disabled to enabled.
1.3.6.1.4.1.5205.2.19.1.20.150NotificationfeL2ModSW24VlanStateDisabledcurrentSend the trap when the operational state of vlan is from enabled to disabled. The OID value means the enabled Group ID.
1.3.6.1.4.1.5205.2.19.1.20.151NotificationfeL2ModSW24VlanPortBaseEnabledcurrentSend the trap when the operational state of vlan is changed to port-based vlan.
1.3.6.1.4.1.5205.2.19.1.20.152NotificationfeL2ModSW24VlanTagBaseEnabledcurrentSend the trap when the operational state of vlan is changed to tag-based vlan.
1.3.6.1.4.1.5205.2.19.1.20.153NotificationfeL2ModSW24VlanMetroModeEnabledcurrentSend the trap when the operational state of vlan is changed to Metro-mode vlan. The OID value means the uplink port with this metro-mode vlan.
1.3.6.1.4.1.5205.2.19.1.20.154NotificationfeL2ModSW24VlanDoubleTagEnabledcurrentSend the trap when the operational state of vlan is changed to Double-tag vlan.
1.3.6.1.4.1.5205.2.19.1.20.200NotificationfeL2ModSW24UserLogincurrentSend the trap when one user logins the system.
1.3.6.1.4.1.5205.2.19.1.20.201NotificationfeL2ModSW24UserLogoutcurrentSend the trap when one user logouts the system.
1.3.6.1.4.1.5205.2.19.1.21NodefeL2ModSW24TrapVariable
1.3.6.1.4.1.5205.2.19.1.21.1Scalarusernameread-onlycurrentSystem account name.
1.3.6.1.4.1.5205.2.19.1.21.2ScalargroupIdread-onlycurrentThe Trunk group ID of LACP.
1.3.6.1.4.1.5205.2.19.1.21.3Scalaractorkeyread-onlycurrentThis is the actor key information for LACP.
1.3.6.1.4.1.5205.2.19.1.21.4Scalarpartnerkeyread-onlycurrentThis is the partner key information for LACP.
1.3.6.1.4.1.5205.2.19.1.21.5Scalaruplinkread-onlycurrentUplink port(s) in the metro-mode vlan.