PRIVATE-FEL2Mod-SW24-MIB
215 objects
The MIB module is for xxx Tech.
Imported Objects
| RFC1213-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 enterprises IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5205 | Identityprivatetech | The MIB module is for xxx Tech. | ||
| 1.3.6.1.4.1.5205.2 | Nodeswitch | |||
| 1.3.6.1.4.1.5205.2.19 | NodefeL2ModSW24ProductID | |||
| 1.3.6.1.4.1.5205.2.19.1 | NodefeL2ModSW24Produces | |||
| 1.3.6.1.4.1.5205.2.19.1.1 | NodefeL2ModSW24System | |||
| 1.3.6.1.4.1.5205.2.19.1.1.1 | NodefeL2ModSW24CommonSys | |||
| 1.3.6.1.4.1.5205.2.19.1.1.1.1 | ScalarfeL2ModSW24Reboot | read-write | current | Reboot the system. Get this OID always return zero. 0 - do nothing 1 - Reboot without saving start 2 - Reboot with saving start |
| 1.3.6.1.4.1.5205.2.19.1.1.1.2 | ScalarfeL2ModSW24BiosVsersion | read-only | current | Get the BIOS version of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.3 | ScalarfeL2ModSW24FirmwareVersion | read-only | current | Get the firmware version of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.4 | ScalarfeL2ModSW24HardwareVersion | read-only | current | Get the hardware version of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.5 | ScalarfeL2ModSW24MechanicalVersion | read-only | current | Get the mechanical version of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.6 | ScalarfeL2ModSW24SerialNumber | read-only | current | Get the Serial number of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.7 | ScalarfeL2ModSW24HostMacAddress | read-only | current | Get the MAC address of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.8 | ScalarfeL2ModSW24DevicePort | read-only | current | Get the quantity of ports that this system owns now. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.9 | ScalarfeL2ModSW24RamSize | read-only | current | Get the RAM size of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.1.10 | ScalarfeL2ModSW24FlashSize | read-only | current | Get the flash size of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.2 | NodefeL2ModSW24IP | |||
| 1.3.6.1.4.1.5205.2.19.1.1.2.1 | ScalarfeL2ModSW24DhcpSetting | read-write | current | Get/Set DHCP status of the system. 0 - DHCP disable 1 - DHCP enable |
| 1.3.6.1.4.1.5205.2.19.1.1.2.2 | ScalarfeL2ModSW24IPAddress | read-write | current | Get/Set the IP address of the system. You can't set this OID if DHCP status is enabled. |
| 1.3.6.1.4.1.5205.2.19.1.1.2.3 | ScalarfeL2ModSW24NetMask | read-write | current | Get/Set the subnet mask of the system. You can't set this OID if DHCP status is enabled. |
| 1.3.6.1.4.1.5205.2.19.1.1.2.4 | ScalarfeL2ModSW24DefaultGateway | read-write | current | Get/Set the default gateway of the system. You can't set this OID if DHCP status is enabled. |
| 1.3.6.1.4.1.5205.2.19.1.1.2.5 | ScalarfeL2ModSW24DnsSetting | read-write | current | Get/Set the source of DNS server. You can't set this OID if DHCP status is disabled. 0 - manual, the DNS server is from manual setting 1 - auto, the DNS server… |
| 1.3.6.1.4.1.5205.2.19.1.1.2.6 | ScalarfeL2ModSW24DnsServer | read-write | current | Get/Set the DNS server of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.3 | NodefeL2ModSW24Time | |||
| 1.3.6.1.4.1.5205.2.19.1.1.3.1 | ScalarfeL2ModSW24SystemCurrentTime | read-only | current | Get the current time of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.3.2 | ScalarfeL2ModSW24ManualTimeSetting | read-write | current | Get/Set the system time of the device. The input format is 'Year/Month/Day/Hour/Minute/Second'. ex: 2004/1/1/12/34/25 means 2004/1/1 - 12:24:25 . The value ran… |
| 1.3.6.1.4.1.5205.2.19.1.1.3.3 | ScalarfeL2ModSW24NTPServer | read-write | current | Get/Set the NTP Time Server. You can use the IP address or domain name. |
| 1.3.6.1.4.1.5205.2.19.1.1.3.4 | ScalarfeL2ModSW24NTPTimeZone | read-write | current | Get/Set the NTP Time Zone. The value range is between -12 and 13 -12 - GMT -12:00, -11 - GMT -11:00, -10 - GMT -10:00, -9 - GMT -09:00, -8 - GMT -08:00, -7 - G… |
| 1.3.6.1.4.1.5205.2.19.1.1.3.5 | ScalarfeL2ModSW24NTPTimeSync | read-write | current | Sync time from NTP Server. Get this OID always return zero. Set the Time Server and Time Zone before doing time sync. Notice that time server must be correct! … |
| 1.3.6.1.4.1.5205.2.19.1.1.3.6 | ScalarfeL2ModSW24DaylightSavingTime | read-write | current | Get/Set the daylight saving time. The value range is between -5 and 5. (Unit: hour) |
| 1.3.6.1.4.1.5205.2.19.1.1.3.7 | ScalarfeL2ModSW24DaylightStartTime | read-write | current | Get/Set the Start time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. example: month/day/hour 10/01… |
| 1.3.6.1.4.1.5205.2.19.1.1.3.8 | ScalarfeL2ModSW24DaylightEndTime | read-write | current | Get/Set the End time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. example: month/day/hour 04/01/0… |
| 1.3.6.1.4.1.5205.2.19.1.1.4 | NodefeL2ModSW24Account | |||
| 1.3.6.1.4.1.5205.2.19.1.1.4.1 | ScalarfeL2ModSW24AccountNumber | read-only | current | Get the current account number(s) of the system. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.2 | TablefeL2ModSW24AccountTable | not-accessible | current | This is a list of FEL2ModSW24AccountEntry. The numbers of entries are given by the value of feL2ModSW24AccountNumber. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.2.1 | RowfeL2ModSW24AccountEntry | not-accessible | current | This is the Entry(s) for account information. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.2.1.1 | ColumnfeL2ModSW24AccountIndex | read-only | current | This is the index of the account entry. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.2.1.2 | ColumnfeL2ModSW24AccountAuthorization | read-only | current | This is the authorization of the account entry. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.2.1.3 | ColumnfeL2ModSW24AccountName | read-write | current | This is the username of the account entry. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.2.1.4 | ColumnfeL2ModSW24AccountPassword | read-write | current | This is the password of the account entry. The return value is always '********'. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.3 | ScalarfeL2ModSW24AccountAddName | read-write | current | This is the account name for adding operation. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.4 | ScalarfeL2ModSW24AccountAddPassword | read-write | current | This is the account password for adding operation. The return value is always '********'. |
| 1.3.6.1.4.1.5205.2.19.1.1.4.5 | ScalarfeL2ModSW24DoAccountAdd | read-write | current | Add account name. OID feL2ModSW24AccountAddName and feL2ModSW24AccountAddPassword must be filled first. Get this OID always return zero. 1 - add account. 0 - d… |
| 1.3.6.1.4.1.5205.2.19.1.1.4.6 | ScalarfeL2ModSW24AccountDel | read-write | current | Delete account. The value is valid feL2ModSW24AccountIndex(Can't delete administrator). |
| 1.3.6.1.4.1.5205.2.19.1.2 | NodefeL2ModSW24Snmp | |||
| 1.3.6.1.4.1.5205.2.19.1.2.1 | ScalarfeL2ModSW24GetCommunity | read-write | current | Get/Set the get-community of the SNMP. |
| 1.3.6.1.4.1.5205.2.19.1.2.2 | ScalarfeL2ModSW24SetCommunity | read-write | current | Get/Set the set-community of the SNMP. |
| 1.3.6.1.4.1.5205.2.19.1.2.3 | ScalarfeL2ModSW24TrapHostNumber | read-only | current | Get the number of trap hosts. |
| 1.3.6.1.4.1.5205.2.19.1.2.4 | TablefeL2ModSW24TrapHostTable | not-accessible | current | A list of trap host entry. The numbers of entries are given by the value of feL2ModSW24TrapHostNumber. |
| 1.3.6.1.4.1.5205.2.19.1.2.4.1 | RowfeL2ModSW24TrapHostEntry | not-accessible | current | This is the entry information for trap host. |
| 1.3.6.1.4.1.5205.2.19.1.2.4.1.1 | ColumnfeL2ModSW24TrapHostIndex | read-only | current | The index of the trap host entry. |
| 1.3.6.1.4.1.5205.2.19.1.2.4.1.2 | ColumnfeL2ModSW24TrapHostIP | read-write | current | This is the IP of the trap host. |
| 1.3.6.1.4.1.5205.2.19.1.2.4.1.3 | ColumnfeL2ModSW24TrapHostPort | read-write | current | This is the receiving-port number of the trap host. |
| 1.3.6.1.4.1.5205.2.19.1.2.4.1.4 | ColumnfeL2ModSW24TrapHostCommunity | read-write | current | The community name for the trap PDU. |
| 1.3.6.1.4.1.5205.2.19.1.3 | NodefeL2ModSW24Alarm | |||
| 1.3.6.1.4.1.5205.2.19.1.3.1 | NodefeL2ModSW24Event | |||
| 1.3.6.1.4.1.5205.2.19.1.3.1.1 | ScalarfeL2ModSW24EventNumber | read-only | current | Get the total number of alarm events. |
| 1.3.6.1.4.1.5205.2.19.1.3.1.2 | TablefeL2ModSW24EventTable | not-accessible | current | A list of alarm event entry. The numbers of entries are given by the value of feL2ModSW24EventNumber. |
| 1.3.6.1.4.1.5205.2.19.1.3.1.2.1 | RowfeL2ModSW24EventEntry | not-accessible | current | This is the entry information for alarm event. |
| 1.3.6.1.4.1.5205.2.19.1.3.1.2.1.1 | ColumnfeL2ModSW24EventIndex | read-only | current | This is the index of the alarm event entry. |
| 1.3.6.1.4.1.5205.2.19.1.3.1.2.1.2 | ColumnfeL2ModSW24EventName | read-only | current | This is the alarm event name. |
| 1.3.6.1.4.1.5205.2.19.1.3.1.2.1.3 | ColumnfeL2ModSW24EventSendEmail | read-write | current | Send email when alarm event is triggered. |
| 1.3.6.1.4.1.5205.2.19.1.3.1.2.1.4 | ColumnfeL2ModSW24EventSendSMS | read-write | current | Send SMS when alarm event is triggered. |
| 1.3.6.1.4.1.5205.2.19.1.3.1.2.1.5 | ColumnfeL2ModSW24EventSendTrap | read-write | current | Send trap when alarm event is triggered. |
| 1.3.6.1.4.1.5205.2.19.1.3.2 | NodefeL2ModSW24Email | |||
| 1.3.6.1.4.1.5205.2.19.1.3.2.1 | ScalarfeL2ModSW24EmailServer | read-write | current | This is the SMTP server for alarm event. |
| 1.3.6.1.4.1.5205.2.19.1.3.2.2 | ScalarfeL2ModSW24EmailUsername | read-write | current | This is the Username of SMTP server. |
| 1.3.6.1.4.1.5205.2.19.1.3.2.3 | ScalarfeL2ModSW24EmailPassword | read-write | current | This is the User Password of SMTP server. |
| 1.3.6.1.4.1.5205.2.19.1.3.2.4 | ScalarfeL2ModSW24EmailUserNumber | read-only | current | The number of the email users that you want to send the alarm notification. |
| 1.3.6.1.4.1.5205.2.19.1.3.2.5 | TablefeL2ModSW24EmailUserTable | not-accessible | current | This is a list of email user entry. The numbers of entries are given by the value of feL2ModSW24EmailUserNumber. |
| 1.3.6.1.4.1.5205.2.19.1.3.2.5.1 | RowfeL2ModSW24EmailUserEntry | not-accessible | current | This is the Entry information for email user entry. |
| 1.3.6.1.4.1.5205.2.19.1.3.2.5.1.1 | ColumnfeL2ModSW24EmailUserIndex | read-only | current | This is the index of the email user entry. |
| 1.3.6.1.4.1.5205.2.19.1.3.2.5.1.2 | ColumnfeL2ModSW24EmailUserAddress | read-write | current | This is the email address of the email user entry. |
| 1.3.6.1.4.1.5205.2.19.1.3.3 | NodefeL2ModSW24SMS | |||
| 1.3.6.1.4.1.5205.2.19.1.3.3.1 | ScalarfeL2ModSW24SMSServer | read-write | current | This is the SMS server for alarm event. |
| 1.3.6.1.4.1.5205.2.19.1.3.3.2 | ScalarfeL2ModSW24SMSUsername | read-write | current | This is the Username of SMS server. |
| 1.3.6.1.4.1.5205.2.19.1.3.3.3 | ScalarfeL2ModSW24SMSPassword | read-write | current | This is the Password of SMS server. |
| 1.3.6.1.4.1.5205.2.19.1.3.3.4 | ScalarfeL2ModSW24SMSUserNumber | read-only | current | The number of the SMS users that you want to send the alarm notification. |
| 1.3.6.1.4.1.5205.2.19.1.3.3.5 | TablefeL2ModSW24SMSUserTable | not-accessible | current | This is a list of SMS user entry. The numbers of entries are given by the value of feL2ModSW24SMSUserNumber. |
| 1.3.6.1.4.1.5205.2.19.1.3.3.5.1 | RowfeL2ModSW24SMSUserEntry | not-accessible | current | This is the Entry information for SMS user entry. |
| 1.3.6.1.4.1.5205.2.19.1.3.3.5.1.1 | ColumnfeL2ModSW24SMSUserIndex | read-only | current | This is the index of the SMS user entry. |
| 1.3.6.1.4.1.5205.2.19.1.3.3.5.1.2 | ColumnfeL2ModSW24SMSUserMobilePhone | read-write | current | The SMS phone number of the SMS user entry. |
| 1.3.6.1.4.1.5205.2.19.1.4 | NodefeL2ModSW24Tftp | |||
| 1.3.6.1.4.1.5205.2.19.1.4.1 | ScalarfeL2ModSW24TftpServer | read-write | current | Get/Set the tftp server. |
| 1.3.6.1.4.1.5205.2.19.1.5 | NodefeL2ModSW24Configuration | |||
| 1.3.6.1.4.1.5205.2.19.1.5.1 | NodefeL2ModSW24SaveRestore | |||
| 1.3.6.1.4.1.5205.2.19.1.5.1.1 | ScalarfeL2ModSW24SaveStart | read-write | current | Save current configuration into flash memory (Save as Start Configuration). Get this OID always return zero. 1 - save. 0 - do nothing. |
| 1.3.6.1.4.1.5205.2.19.1.5.1.2 | ScalarfeL2ModSW24SaveUser | read-write | current | Save current configuration into flash memory (Save as User Configuration). Get this OID always return zero. 1 - save. 0 - do nothing. |
| 1.3.6.1.4.1.5205.2.19.1.5.1.3 | ScalarfeL2ModSW24RestoreDefault | read-write | current | Restore factory default configuration. Get this OID always return zero. 2 - restore default included default ip address. 1 - restore default without changing c… |
| 1.3.6.1.4.1.5205.2.19.1.5.1.4 | ScalarfeL2ModSW24RestoreUser | read-write | current | Restore user configuration. Get this OID always return zero. 1 - restore. 0 - do nothing. |
| 1.3.6.1.4.1.5205.2.19.1.5.2 | NodefeL2ModSW24ConfigFile | |||
| 1.3.6.1.4.1.5205.2.19.1.5.2.1 | ScalarfeL2ModSW24ExportConfigName | read-write | current | Get/Set the export file path and name. |
| 1.3.6.1.4.1.5205.2.19.1.5.2.2 | ScalarfeL2ModSW24DoExportConfig | read-write | current | Do export-config. Get this oid always return zero. 1 - export start section. 2 - export user-conf section. |
| 1.3.6.1.4.1.5205.2.19.1.5.2.3 | ScalarfeL2ModSW24ImportConfigName | read-write | current | Get/Set the import file path and name. |
| 1.3.6.1.4.1.5205.2.19.1.5.2.4 | ScalarfeL2ModSW24DoImportConfig | read-write | current | Do import-config. Get this OID always return zero. 1 - import start section. 2 - import user-conf section. |
| 1.3.6.1.4.1.5205.2.19.1.6 | NodefeL2ModSW24Diagnostic | |||
| 1.3.6.1.4.1.5205.2.19.1.6.1 | ScalarfeL2ModSW24EEPROMTest | read-only | current | EEPROM access test. |
| 1.3.6.1.4.1.5205.2.19.1.6.2 | ScalarfeL2ModSW24UartTest | read-only | current | UART access test. |
| 1.3.6.1.4.1.5205.2.19.1.6.3 | ScalarfeL2ModSW24DramTest | read-only | current | DRAM access test. |
| 1.3.6.1.4.1.5205.2.19.1.6.4 | ScalarfeL2ModSW24FlashTest | read-only | current | Flash memory access test. |
| 1.3.6.1.4.1.5205.2.19.1.6.5 | ScalarfeL2ModSW24InternalLoopbackTest | read-only | current | Internal loopback test. |
| 1.3.6.1.4.1.5205.2.19.1.6.6 | ScalarfeL2ModSW24ExternalLoopbackTest | read-only | current | External loopback test. |
| 1.3.6.1.4.1.5205.2.19.1.6.7 | ScalarfeL2ModSW24PingTest | read-write | current | Set the host address that you want to ping and the system will return the test result. |
| 1.3.6.1.4.1.5205.2.19.1.7 | NodefeL2ModSW24Log | |||
| 1.3.6.1.4.1.5205.2.19.1.7.1 | ScalarfeL2ModSW24ClearLog | read-write | current | Clear system log. Get this OID always return zero. 1 - clear log. 0 - do nothing. |
| 1.3.6.1.4.1.5205.2.19.1.7.2 | ScalarfeL2ModSW24UploadLog | read-write | current | Upload current system log. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return zero.… |
| 1.3.6.1.4.1.5205.2.19.1.7.3 | ScalarfeL2ModSW24AutoUploadLogState | read-write | current | Enable auto-upload log function. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return… |
| 1.3.6.1.4.1.5205.2.19.1.7.4 | ScalarfeL2ModSW24LogNumber | read-only | current | Get the number of current system log. |
| 1.3.6.1.4.1.5205.2.19.1.7.5 | TablefeL2ModSW24LogTable | not-accessible | current | This is a list of log entry. The numbers of entries are given by the value of feL2ModSW24LogNumber. |
| 1.3.6.1.4.1.5205.2.19.1.7.5.1 | RowfeL2ModSW24LogEntry | not-accessible | current | This is the Entry information for system log. |
| 1.3.6.1.4.1.5205.2.19.1.7.5.1.1 | ColumnfeL2ModSW24LogIndex | read-only | current | This is the index of the log entry. |
| 1.3.6.1.4.1.5205.2.19.1.7.5.1.2 | ColumnfeL2ModSW24LogEvent | read-only | current | This is the detail information of the log entry. |
| 1.3.6.1.4.1.5205.2.19.1.8 | NodefeL2ModSW24Firmware | |||
| 1.3.6.1.4.1.5205.2.19.1.8.1 | ScalarfeL2ModSW24FirmwareFileName | read-write | current | Get/Set the path and filename for firmware upgrading. |
| 1.3.6.1.4.1.5205.2.19.1.8.2 | ScalarfeL2ModSW24DoFirmwareUpgrade | read-write | current | Do firmware upgrade. Get this OID always return zero. 1 - do firmware upgrade. 0 - do nothing. |
| 1.3.6.1.4.1.5205.2.19.1.9 | NodefeL2ModSW24Port | |||
| 1.3.6.1.4.1.5205.2.19.1.9.1 | NodefeL2ModSW24PortStatus | |||
| 1.3.6.1.4.1.5205.2.19.1.9.1.1 | ScalarfeL2ModSW24PortStatusNumber | read-only | current | Get the number of port. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2 | TablefeL2ModSW24PortStatusTable | not-accessible | current | This is a list of port status entry. The numbers of entries are given by the value of feL2ModSW24PortStatusNumber. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1 | RowfeL2ModSW24PortStatusEntry | not-accessible | current | This is the entry(s) for port status information. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.1 | ColumnfeL2ModSW24PortStatusIndex | read-only | current | This is the index of the port status entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.2 | ColumnfeL2ModSW24PortStatusMedia | read-only | current | The port media type of the port status entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.3 | ColumnfeL2ModSW24PortStatusLink | read-only | current | This is the port link of the port status entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.4 | ColumnfeL2ModSW24PortStatusPortState | read-only | current | This is the port state of the port status entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.5 | ColumnfeL2ModSW24PortStatusAutoNego | read-only | current | This is the auto negotiation of the port status entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.6 | ColumnfeL2ModSW24PortStatusSpdDpx | read-only | current | This is the speed/duplex of the port status entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.7 | ColumnfeL2ModSW24PortStatusFlwCtrl | read-only | current | This is the flow control of the port status entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.1.2.1.8 | ColumnfeL2ModSW24PortStatuDescription | read-only | current | The description of port. |
| 1.3.6.1.4.1.5205.2.19.1.9.2 | NodefeL2ModSW24PortConf | |||
| 1.3.6.1.4.1.5205.2.19.1.9.2.1 | ScalarfeL2ModSW24PortConfNumber | read-only | current | Get the number of port configuration. |
| 1.3.6.1.4.1.5205.2.19.1.9.2.2 | TablefeL2ModSW24PortConfTable | not-accessible | current | This is a list of port configuration entry. The numbers of entries are given by the value of feL2ModSW24PortConfNumber. |
| 1.3.6.1.4.1.5205.2.19.1.9.2.2.1 | RowfeL2ModSW24PortConfEntry | not-accessible | current | This is the Entry(s) for port configuration information. |
| 1.3.6.1.4.1.5205.2.19.1.9.2.2.1.1 | ColumnfeL2ModSW24PortConfIndex | read-only | current | This is the index of the port configuration entry. |
| 1.3.6.1.4.1.5205.2.19.1.9.2.2.1.2 | ColumnfeL2ModSW24PortConfPortState | read-write | current | This is the port state of the port configuration entry. 0 - disabled. 1 - enabled. |
| 1.3.6.1.4.1.5205.2.19.1.9.2.2.1.3 | ColumnfeL2ModSW24PortConfSpdDpx | read-write | current | This is the speed/duplex of the port configuration entry. 0 - auto. 1 - 10M/Half. 2 - 10M/Full. 3 - 100M/Half. 4 - 100M/Full. 5 - 1G/Full. |
| 1.3.6.1.4.1.5205.2.19.1.9.2.2.1.4 | ColumnfeL2ModSW24PortConfFlwCtrl | read-write | current | This is the flow control of the port configuration entry. 0 - disabled. 1 - enabled. |
| 1.3.6.1.4.1.5205.2.19.1.9.2.2.1.5 | ColumnfeL2ModSW24PortConfDescription | read-write | current | The description of port. |
| 1.3.6.1.4.1.5205.2.19.1.10 | NodefeL2ModSW24Mirror | |||
| 1.3.6.1.4.1.5205.2.19.1.10.1 | ScalarfeL2ModSW24MirrorMode | read-write | current | Get/Set the Mirror mode. 0 - disabled. 1 - rx enable. |
| 1.3.6.1.4.1.5205.2.19.1.10.2 | ScalarfeL2ModSW24MirroringPort | read-write | current | Get/Set the mirroring port. The port range is from 1 to 24. |
| 1.3.6.1.4.1.5205.2.19.1.10.3 | ScalarfeL2ModSW24MirroredPorts | read-write | current | Get/Set the monitored ports. The port range is from 1 to 24, and the syntax is 1,5-7. |
| 1.3.6.1.4.1.5205.2.19.1.11 | NodefeL2ModSW24MaxPktLen | |||
| 1.3.6.1.4.1.5205.2.19.1.11.1 | NodefeL2ModSW24MaxPktLen1 | |||
| 1.3.6.1.4.1.5205.2.19.1.11.1.1 | ScalarfeL2ModSW24MaxPktLenPortNumber | read-only | current | Get the number of Max. packet length. |
| 1.3.6.1.4.1.5205.2.19.1.11.1.2 | TablefeL2ModSW24MaxPktLenConfTable | not-accessible | current | This is a list of Max. packet length entry. The numbers of entries are given by the value of feL2ModSW24MaxPktLenPortNumber. |
| 1.3.6.1.4.1.5205.2.19.1.11.1.2.1 | RowfeL2ModSW24MaxPktLenConfEntry | not-accessible | current | Entry(s) for Max. packet length information. |
| 1.3.6.1.4.1.5205.2.19.1.11.1.2.1.1 | ColumnfeL2ModSW24MaxPktLenConfIndex | read-only | current | This is the index of the Max. packet length entry. |
| 1.3.6.1.4.1.5205.2.19.1.11.1.2.1.2 | ColumnfeL2ModSW24MaxPktLenConfSetting | read-write | current | Get/Set the Max. packet length. The Max. packet length is 1518,1532,or 9216. |
| 1.3.6.1.4.1.5205.2.19.1.12 | NodefeL2ModSW24Bandwidth | |||
| 1.3.6.1.4.1.5205.2.19.1.12.1 | NodefeL2ModSW24Bandwidth1 | |||
| 1.3.6.1.4.1.5205.2.19.1.12.1.1 | ScalarfeL2ModSW24BandwidthPortNumber | read-only | current | Get the number of bandwidth management configuration. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2 | TablefeL2ModSW24BandwidthConfTable | not-accessible | current | A list of bandwidth management configuration entry. The numbers of entries are given by the value of feL2ModSW24BandwidthPortNumber. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1 | RowfeL2ModSW24BandwidthConfEntry | not-accessible | current | This is the Entry(s) for bandwidth management configuration information. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1.1 | ColumnfeL2ModSW24BandwidthConfIndex | read-only | current | This is the index of the bandwidth management configuration entry. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1.2 | ColumnfeL2ModSW24BandwidthConfIngressState | read-write | current | The ingress state of the bandwidth management configures entry. 0 - disabled. 1 - enabled. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1.3 | ColumnfeL2ModSW24BandwidthConfIngressBW | read-write | current | Get/Set the ingress rate of the bandwidth management configuration. The ingress rate is from 0 to 1000. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1.4 | ColumnfeL2ModSW24BandwidthConfStormState | read-write | current | The storm state of the bandwidth management configuration entry. 0 - disabled. 1 - enabled. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1.5 | ColumnfeL2ModSW24BandwidthConfStormBW | read-write | current | Get/Set the storm rate of the bandwidth management configuration. The storm rate is from 0 to 1000. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1.6 | ColumnfeL2ModSW24BandwidthConfEgressState | read-write | current | The egress state of the bandwidth management configuration entry. 0 - disabled. 1 - enabled. |
| 1.3.6.1.4.1.5205.2.19.1.12.1.2.1.7 | ColumnfeL2ModSW24BandwidthConfEgressBW | read-write | current | Get/Set the egress rate of the bandwidth management configuration. The egress rate is from 0 to 1000. |
| 1.3.6.1.4.1.5205.2.19.1.13 | NodefeL2ModSW24LoopDetectedConf | |||
| 1.3.6.1.4.1.5205.2.19.1.13.1 | ScalarfeL2ModSW24LoopDetectedNumber | read-only | current | Get the number of loop detected entry. |
| 1.3.6.1.4.1.5205.2.19.1.13.2 | TablefeL2ModSW24LoopDetectedTable | not-accessible | current | A list of loop detected entry. The numbers of entries are given by the value of feL2ModSW24LoopDetectedNumber. |
| 1.3.6.1.4.1.5205.2.19.1.13.2.1 | RowfeL2ModSW24LoopDetectedEntry | not-accessible | current | Entry(s) for loop detected information. |
| 1.3.6.1.4.1.5205.2.19.1.13.2.1.1 | ColumnfeL2ModSW24LoopDetectedfIndex | read-only | current | The index of the loop detected entry. |
| 1.3.6.1.4.1.5205.2.19.1.13.2.1.2 | ColumnfeL2ModSW24LoopDetectedStateEbl | read-write | current | The state of the loop detected entry. 0 - disabled. 1 - enabled. |
| 1.3.6.1.4.1.5205.2.19.1.13.2.1.3 | ColumnfeL2ModSW24LoopDetectedCurrentStatus | read-only | current | The current status of the loop detected port. 0 - unlocked 1 - locked due to the loop condition |
| 1.3.6.1.4.1.5205.2.19.1.13.2.1.4 | ColumnfeL2ModSW24LoopDetectedResumed | read-write | current | Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - unlock the port, 0 - do nothing. |
| 1.3.6.1.4.1.5205.2.19.1.13.3 | ScalarfeL2ModSW24LoopDetectedAction | read-write | current | Set the corresponding action while loop is detected. 1 - lock the loop port, 0 - do nothing. |
| 1.3.6.1.4.1.5205.2.19.1.14 | NodefeL2ModSW24SFPInfo | |||
| 1.3.6.1.4.1.5205.2.19.1.14.1 | ScalarfeL2ModSW24SFPInfoNumber | read-only | current | Get the number of sfp info entry. |
| 1.3.6.1.4.1.5205.2.19.1.14.2 | TablefeL2ModSW24SFPInfoTable | not-accessible | current | A list of sfp info entry. The numbers of entries are given by the value of feL2ModSW24SFPInfoNumber. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1 | RowfeL2ModSW24SFPInfoEntry | not-accessible | current | Entry(s) for SFP information. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.1 | ColumnfeL2ModSW24SFPInfoIndex | read-only | current | The index of the sfp info entry. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.2 | ColumnfeL2ModSW24SFPConnectorType | read-only | current | Get connector type of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.3 | ColumnfeL2ModSW24SFPFiberType | read-only | current | Get fiber type of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.4 | ColumnfeL2ModSW24SFPWavelength | read-only | current | Get tx central wavelength of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.5 | ColumnfeL2ModSW24SFPBaudRate | read-only | current | Get baud rate of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.6 | ColumnfeL2ModSW24SFPVendorOUI | read-only | current | Get vendor OUI of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.7 | ColumnfeL2ModSW24SFPVendorName | read-only | current | Get vendor name of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.8 | ColumnfeL2ModSW24SFPVendorPN | read-only | current | Get vendor part number of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.9 | ColumnfeL2ModSW24SFPVendorRev | read-only | current | Get vendor revision number of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.10 | ColumnfeL2ModSW24SFPVendorSN | read-only | current | Get vendor serial number of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.11 | ColumnfeL2ModSW24SFPDateCode | read-only | current | Get data code of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.12 | ColumnfeL2ModSW24SFPTemperature | read-only | current | Get current temperature of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.13 | ColumnfeL2ModSW24SFPVcc | read-only | current | Get current internal supply voltage of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.14 | ColumnfeL2ModSW24SFPTxBias | read-only | current | Get current TX Bias of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.15 | ColumnfeL2ModSW24SFPTxPWR | read-only | current | Get current TX output power of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.14.2.1.16 | ColumnfeL2ModSW24SFPRxPWR | read-only | current | Get current Received Power of the sfp. |
| 1.3.6.1.4.1.5205.2.19.1.20 | NodefeL2ModSW24TrapEntry | |||
| 1.3.6.1.4.1.5205.2.19.1.20.1 | NotificationfeL2ModSW24ModuleInserted | current | Send the trap when a module is inserted to the system. The OID value means the port number. | |
| 1.3.6.1.4.1.5205.2.19.1.20.2 | NotificationfeL2ModSW24ModuleRemoved | current | Send the trap when a module is removed from the system. The OID value means the port number. | |
| 1.3.6.1.4.1.5205.2.19.1.20.5 | NotificationfeL2ModSW24LoopDetected | current | Send the trap when loop condition has been detected. The OID value means the port number. | |
| 1.3.6.1.4.1.5205.2.19.1.20.100 | NotificationfeL2ModSW24StpStateDisabled | current | Send the trap when the operational state of STP is from enabled to disabled. | |
| 1.3.6.1.4.1.5205.2.19.1.20.101 | NotificationfeL2ModSW24StpStateEnabled | current | Send the trap when the operational state of STP is from disabled to enabled. | |
| 1.3.6.1.4.1.5205.2.19.1.20.102 | NotificationfeL2ModSW24StpTopologyChanged | current | Send the trap when RSTP determines a port should enter the FORWARDING state (a topology change occurs). The OID value is the ifIndex of the port that produces … | |
| 1.3.6.1.4.1.5205.2.19.1.20.120 | NotificationfeL2ModSW24LacpStateDisabled | current | Send the trap when the operational state of LACP is from enabled to disabled. The OID value means the disabled Group ID. | |
| 1.3.6.1.4.1.5205.2.19.1.20.121 | NotificationfeL2ModSW24LacpStateEnabled | current | Send the trap when the operational state of LACP is from disabled to enabled. The OID value means the disabled Group ID. | |
| 1.3.6.1.4.1.5205.2.19.1.20.123 | NotificationfeL2ModSW24LacpPortAdded | current | Send the trap when the state of port is in 'trunk ready'. | |
| 1.3.6.1.4.1.5205.2.19.1.20.124 | NotificationfeL2ModSW24LacpPortTrunkFailure | current | Send the trap when one port is not able to be aggregated due to duplex-mode of the port. | |
| 1.3.6.1.4.1.5205.2.19.1.20.140 | NotificationfeL2ModSW24GvrpStateDisabled | current | Send the trap when the operational state of GVRP is from enabled to disabled. | |
| 1.3.6.1.4.1.5205.2.19.1.20.141 | NotificationfeL2ModSW24GvrpStateEnabled | current | Send the trap when the operational state of LACP is from disabled to enabled. | |
| 1.3.6.1.4.1.5205.2.19.1.20.150 | NotificationfeL2ModSW24VlanStateDisabled | current | Send the trap when the operational state of vlan is from enabled to disabled. The OID value means the enabled Group ID. | |
| 1.3.6.1.4.1.5205.2.19.1.20.151 | NotificationfeL2ModSW24VlanPortBaseEnabled | current | Send the trap when the operational state of vlan is changed to port-based vlan. | |
| 1.3.6.1.4.1.5205.2.19.1.20.152 | NotificationfeL2ModSW24VlanTagBaseEnabled | current | Send the trap when the operational state of vlan is changed to tag-based vlan. | |
| 1.3.6.1.4.1.5205.2.19.1.20.153 | NotificationfeL2ModSW24VlanMetroModeEnabled | current | Send the trap when the operational state of vlan is changed to Metro-mode vlan. The OID value means the uplink port with this metro-mode vlan. | |
| 1.3.6.1.4.1.5205.2.19.1.20.154 | NotificationfeL2ModSW24VlanDoubleTagEnabled | current | Send the trap when the operational state of vlan is changed to Double-tag vlan. | |
| 1.3.6.1.4.1.5205.2.19.1.20.200 | NotificationfeL2ModSW24UserLogin | current | Send the trap when one user logins the system. | |
| 1.3.6.1.4.1.5205.2.19.1.20.201 | NotificationfeL2ModSW24UserLogout | current | Send the trap when one user logouts the system. | |
| 1.3.6.1.4.1.5205.2.19.1.21 | NodefeL2ModSW24TrapVariable | |||
| 1.3.6.1.4.1.5205.2.19.1.21.1 | Scalarusername | read-only | current | System account name. |
| 1.3.6.1.4.1.5205.2.19.1.21.2 | ScalargroupId | read-only | current | The Trunk group ID of LACP. |
| 1.3.6.1.4.1.5205.2.19.1.21.3 | Scalaractorkey | read-only | current | This is the actor key information for LACP. |
| 1.3.6.1.4.1.5205.2.19.1.21.4 | Scalarpartnerkey | read-only | current | This is the partner key information for LACP. |
| 1.3.6.1.4.1.5205.2.19.1.21.5 | Scalaruplink | read-only | current | Uplink port(s) in the metro-mode vlan. |