MIB Viewer

PROTECTION-MIB

98 objects
This MIB describe protection mechanisms used by SDH equipment
Imported Objects
EQUIPMENT-MIBSagemBoolean Severity
SAGEM-DR-MIBIMPORTS sagemDr
SNMPv2-SMIMODULE-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.1038.130IdentityprotectionThis MIB describe protection mechanisms used by SDH equipment
1.3.6.1.4.1.1038.130.10Nodemsp
1.3.6.1.4.1.1038.130.10.1ScalarmspNumberread-onlycurrentNumber of multiplex section protection in equipment.
1.3.6.1.4.1.1038.130.10.2TablemspTablenot-accessiblecurrentList of multiplex section protection in equipment.
1.3.6.1.4.1.1038.130.10.2.1RowmspEntrynot-accessiblecurrentA particular multiplex section protection of the equipment. Each entry is created in using the msTTPTable of the Sdh-Ets MIB.
1.3.6.1.4.1.1038.130.10.2.1.1ColumnmspIndexread-onlycurrentA unique value which identify a particular multiplex section protection. This index is equal to an msTTPIndex(=spiIndex) which gives the interface involved . T…
1.3.6.1.4.1.1038.130.10.2.1.2ColumnmspWorkingPointerread-onlycurrentA reference to the object which sends the data flow to this function on working synchronous port interface side. In most equipments, this value cannot be chang…
1.3.6.1.4.1.1038.130.10.2.1.3ColumnmspProtectionPointerread-writecurrentA reference to the object which sends the data flow to this function on protection synchronous port interface side. In most equipments, this value cannot be ch…
1.3.6.1.4.1.1038.130.10.2.1.4ColumnmspTyperead-writecurrentIndication of the protection type.
1.3.6.1.4.1.1038.130.10.2.1.5ColumnmspDirread-writecurrentIndication of the direction.
1.3.6.1.4.1.1038.130.10.2.1.6ColumnmspTrafficread-onlycurrentThe value of this field indicates the protection switch position.
1.3.6.1.4.1.1038.130.10.2.1.7ColumnmspRevertiveread-writecurrentIf the value is true the msp function is allowed to spontaneously switch back to working chanel when it is available. If not, the msp can switch back to workin…
1.3.6.1.4.1.1038.130.10.2.1.8ColumnmspWtrread-writecurrentThe time (in seconds) the msp function waits before considering a chanel as good after a fail.
1.3.6.1.4.1.1038.130.10.2.1.9ColumnmspSfSdPriorityread-writecurrentSignal Fail and Signal Degrade can be treated according to two set of priority. The equipement will send SF and SD events according to the value of this field.
1.3.6.1.4.1.1038.130.10.2.1.10ColumnmspSfSdHoldOffTimeread-writecurrentThe period (in tenth of seconds) during which a sf or a Signal Degrade is ignored by the MSP switch.
1.3.6.1.4.1.1038.130.10.2.1.11ColumnmspCommandread-writecurrentManual or forced commands can be apply to the protection switch. The forced and manual switch can be refused or cleared by equipment if a higher priority APS c…
1.3.6.1.4.1.1038.130.10.2.1.12ColumnmspInitiatorread-onlycurrentIndicates the initiator equipment.
1.3.6.1.4.1.1038.130.10.2.1.13ColumnmspStatusread-onlycurrentIndicates the initiator equipment status : lockoutProtection(15), forcedSwitch(14), highSF(13), lowSF(12), highSD(11), lowSD(10), manualSwitch(8), waitToRestor…
1.3.6.1.4.1.1038.130.10.2.1.14ColumnmspMonitorread-writecurrentWhen the value of this field is set to false, the failure detection is stopped for this multiplex section protection.
1.3.6.1.4.1.1038.130.10.2.1.15ColumnmspFailureread-onlycurrentActive failures on multiplex section protection.
1.3.6.1.4.1.1038.130.10.2.1.16ColumnmspSeverityread-onlycurrentA reference to failure severity for multiplex section protection.
1.3.6.1.4.1.1038.130.10.2.1.20ColumnmspPamread-writecurrentSeverity associed with Protection Architecture Mismatch failure for multiplex section protection.
1.3.6.1.4.1.1038.130.10.2.1.21ColumnmspScmread-writecurrentSeverity associed with Selector Control Mismatch failure for multiplex section protection.
1.3.6.1.4.1.1038.130.10.2.1.22ColumnmspOtmread-writecurrentSeverity associed with Operation Type Mismatch failure for multiplex section protection.
1.3.6.1.4.1.1038.130.20NodemsSPRing
1.3.6.1.4.1.1038.130.20.1ScalarmsSPRingNumberread-onlycurrentNumber of multiplex section protection in equipment.
1.3.6.1.4.1.1038.130.20.6TablemsSPRingTablenot-accessiblecurrentList of multiplex section protection in equipment.
1.3.6.1.4.1.1038.130.20.6.1RowmsSPRingEntrynot-accessiblecurrentA particular multiplex section protection of the equipment. Each entry is created in using the msTTPTable of the Sdh-Ets MIB. spiIndex gives the interface invo…
1.3.6.1.4.1.1038.130.20.6.1.1ColumnmsSPRingIndexread-onlycurrentA unique value which identify a particular SPRing = West STM index.
1.3.6.1.4.1.1038.130.20.6.1.2ColumnmsSPRingWestPointerread-onlycurrentA reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and p…
1.3.6.1.4.1.1038.130.20.6.1.3ColumnmsSPRingEastPointerread-writecurrentA reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and p…
1.3.6.1.4.1.1038.130.20.6.1.5ColumnmsSPRingWtrread-writecurrentThe time (in seconds) the spring function waits before considering a chanel as good after a fail.
1.3.6.1.4.1.1038.130.20.6.1.6ColumnmsSPRingSfSdHoldOffTimeread-writecurrentThe period (in tenth of seconds) during which a sf or a Signal Degrade is ignored by the SPRing switch.
1.3.6.1.4.1.1038.130.20.6.1.7ColumnmsSPRingCommandSideread-writecurrentSide of the command
1.3.6.1.4.1.1038.130.20.6.1.8ColumnmsSPRingCommandread-writecurrentManual or forced commands can be apply to the protection switch.
1.3.6.1.4.1.1038.130.20.6.1.10ColumnmsSPRingInitiator1read-onlycurrentA reference(ID) to the equipment that initiate the SWITCH; this is mainly the Master when the equipment is in SWITCH state; in some case like bidirectional SF …
1.3.6.1.4.1.1038.130.20.6.1.11ColumnmsSPRingInitiator2read-onlycurrentA reference(ID) to the equipment that respond to the SWITCH; this is mainly the Slave when the equipment is in SWITCH state; in some case like bidirectional SF…
1.3.6.1.4.1.1038.130.20.6.1.12ColumnmsSPRingMonitorread-writecurrentWhen the value of this field is set to false, the failure detection is stopped for this multiplex section protection.
1.3.6.1.4.1.1038.130.20.6.1.13ColumnmsSPRingFailureread-onlycurrentActive failures on multiplex section protection
1.3.6.1.4.1.1038.130.20.6.1.14ColumnmsSPRingSeverityread-onlycurrentA reference to failure severity for multiplex section protection.
1.3.6.1.4.1.1038.130.20.6.1.21ColumnmsSPRingAtoread-writecurrentSeverity associed with APS Time Out failure failure for MS-SPRing.
1.3.6.1.4.1.1038.130.20.6.1.22ColumnmsSPRingArvread-writecurrentSeverity associed with APS Rules Violation failure failure for MS-SPRing.
1.3.6.1.4.1.1038.130.20.6.1.23ColumnmsSPRingAunread-writecurrentSeverity associed with APS Unknown Node failure failure for MS-SPRing.
1.3.6.1.4.1.1038.130.20.6.1.24ColumnmsSPRingPtmread-writecurrentSeverity associed with Potential Traffic Misconnection failure for MS-SPRing.
1.3.6.1.4.1.1038.130.20.6.1.25ColumnmsSPRingMmsread-writecurrentSeverity associed with Mutiple Multiplex Section Fail failure for MS-SPRing.
1.3.6.1.4.1.1038.130.20.6.1.26ColumnmsSPRingExrread-writecurrentSeverity associed with EXeRcise failure for MS-SPRing.
1.3.6.1.4.1.1038.130.20.6.1.27ColumnmsSPRingSimpleFailureread-writecurrentIndicate if simple or multi ring failure must be considerated
1.3.6.1.4.1.1038.130.20.6.1.28ColumnmsSPRingIdread-writecurrentRing Identifier of the equipement
1.3.6.1.4.1.1038.130.20.6.1.29ColumnmsSPRingNodeStateread-onlycurrent
1.3.6.1.4.1.1038.130.20.6.1.30ColumnmsSPRingSwitchingSideread-onlycurrentSwitching SideSide
1.3.6.1.4.1.1038.130.20.6.1.31ColumnmsSPRingWestTrafficread-onlycurrentThe value of this field indicates the protection switch position.
1.3.6.1.4.1.1038.130.20.6.1.32ColumnmsSPRingEastTrafficread-onlycurrentThe value of this field indicates the protection switch position.
1.3.6.1.4.1.1038.130.20.6.1.33ColumnmsSPRingWestStatusread-onlycurrentIndicates the local status: OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8), manualSwitch-R(6), waitToRestore(5),exer-R(3),noRequest(0)
1.3.6.1.4.1.1038.130.20.6.1.34ColumnmsSPRingEastStatusread-onlycurrentIndicates the local status: OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8), manualSwitch-R(6), waitToRestore(5),exer-R(3),noRequest(0)
1.3.6.1.4.1.1038.130.20.11TablemsSPRingTopoMapTablenot-accessiblecurrentTopology Map of the ring = West STM index + Val (1<=Val<=16).
1.3.6.1.4.1.1038.130.20.11.1RowmsSPRingTopoMapEntrynot-accessiblecurrentA particular entry of the ring topology map.
1.3.6.1.4.1.1038.130.20.11.1.1ColumnmsSPRingTopoMapIndexread-onlycurrentindex
1.3.6.1.4.1.1038.130.20.11.1.2ColumnmsSPRingTopoMapIDread-writecurrentidentifier of the node
1.3.6.1.4.1.1038.130.20.21TablemsSPRingMisconMapTablenot-accessiblecurrentConnectivity (misconnection) Map of the ring.
1.3.6.1.4.1.1038.130.20.21.1RowmsSPRingMisconMapEntrynot-accessiblecurrentA particular entry of the ring connectivity (misconnection) map. All entries are created after setting the msSPRingWestPointer.
1.3.6.1.4.1.1038.130.20.21.1.1ColumnmsSPRingMisconMapIndexread-onlycurrentIndex = West STM index + Val (1<=Val<=16) ADR2500c : val = 1 to 8 for West and 9 to 16 for East
1.3.6.1.4.1.1038.130.20.21.1.2ColumnmsSPRingMisconMapSideread-onlycurrentSide (WestPointer/msSPRingEast) of the interface that supports the AU4
1.3.6.1.4.1.1038.130.20.21.1.3ColumnmsSPRingMisconMapInread-writecurrentNode of the ring where the Au4 traffic enters the ring
1.3.6.1.4.1.1038.130.20.21.1.4ColumnmsSPRingMisconMapOutread-writecurrentNode of the ring where the Au4 traffic exits the ring
1.3.6.1.4.1.1038.130.20.21.1.5ColumnmsSPRingMisconMapTimeSlotread-writecurrentTime Slot assignment for the AU4
1.3.6.1.4.1.1038.130.20.21.1.6ColumnmsSPRingMisconMapTyperead-writecurrentIf the value is equal to terminated, the traffic in the ring is inserted or extracted at this node. If the value is equal to passedThrough the traffic only cro…
1.3.6.1.4.1.1038.130.20.21.1.7ColumnmsSPRingMisconMapLOAccessread-writecurrentTrue if the AU4 is accessed at LO layers somewhere in the ring
1.3.6.1.4.1.1038.130.20.31TablemsSPRingNUTTablenot-accessiblecurrentTopology Map of the ring.
1.3.6.1.4.1.1038.130.20.31.1RowmsSPRingNUTEntrynot-accessiblecurrentA particular entry of the ring topology map.
1.3.6.1.4.1.1038.130.20.31.1.1ColumnmsSPRingNUTIndexread-onlycurrentAU4 index = West STM index + Val (Val = working timeSlot; 1<=Val<=8)
1.3.6.1.4.1.1038.130.20.31.1.2ColumnmsSPRingNUTisNutread-writecurrentDefine if the traffic is used for NUT Traffic
1.3.6.1.4.1.1038.130.30Nodesncp
1.3.6.1.4.1.1038.130.30.1ScalarsncNumberread-onlycurrentNumber of snc in equipment.
1.3.6.1.4.1.1038.130.30.2TablesncTablenot-accessiblecurrentList of snc protection in equipment.
1.3.6.1.4.1.1038.130.30.2.1RowsncEntrynot-accessiblecurrentA particular SNC protection which is created in using the linkTable of the Xconnection MIB.
1.3.6.1.4.1.1038.130.30.2.1.1ColumnsncIndexread-onlycurrentsncIndex = 1000*sncType + sncTTPSink = linkIndex
1.3.6.1.4.1.1038.130.30.2.1.2ColumnsncCTPSinkread-onlycurrentThe value of this field is the index of the Output Connection to which an snc function is applied.
1.3.6.1.4.1.1038.130.30.2.1.3ColumnsncLinkTyperead-onlycurrentTrail level of the connection
1.3.6.1.4.1.1038.130.30.2.1.4ColumnsncCTPSourceWread-onlycurrentThe value of this field indicates the Working Input Connection Point which composes the protection link of the Output Connection Point (sncIndex).
1.3.6.1.4.1.1038.130.30.2.1.5ColumnsncCTPSourcePread-writecurrentThe value of this field indicates the Protected Input Connection Point which composes the protection link of the Output Connection Point (sncIndex). When this …
1.3.6.1.4.1.1038.130.30.2.1.6ColumnsncTrafficStatusread-onlycurrentThis field indicates the Protection unit switch position.
1.3.6.1.4.1.1038.130.30.2.1.8ColumnsncWorkingTriggerTyperead-writecurrentThe value of this field is the criterion to trigger a switch for the Working Input Connection Point.SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC…
1.3.6.1.4.1.1038.130.30.2.1.9ColumnsncProtectionTriggerTyperead-writecurrentThe value of this field is the criterion to trigger a switch for the Protection Input Connection Point. SNC/I uses SF criterion for switching: TU-AIS/TU-LOP fo…
1.3.6.1.4.1.1038.130.30.2.1.20ColumnsncRevertiveread-writecurrentIf the value is true the Protection unit function is allowed to spontaneously switch back to working chanel when it is available. If not, the snc can switch ba…
1.3.6.1.4.1.1038.130.30.2.1.21ColumnsncWtrread-writecurrentThe time (in seconds) the Protection unit function waits before considering a chanel as good after a fail.
1.3.6.1.4.1.1038.130.30.2.1.22ColumnsncStateProcessread-onlycurrentThe value of this field indicates the state of the snc protection process.
1.3.6.1.4.1.1038.130.30.2.1.23ColumnsncHoldOffTimeread-writecurrentThe time in tenth of seconds during which a protection trigger criterion is ignored.
1.3.6.1.4.1.1038.130.30.2.1.24ColumnsncCommandread-writecurrentManual or forced commands can be apply to the protection unit. The forced and manual switch can be refused or cleared by equipment if a higher priority eveneme…
1.3.6.1.4.1.1038.130.40Nodecardp
1.3.6.1.4.1.1038.130.40.1ScalarcardpNumberread-onlycurrentNumber of card protections in equipment.
1.3.6.1.4.1.1038.130.40.2TablecardpTablenot-accessiblecurrentList of card protections in equipment.
1.3.6.1.4.1.1038.130.40.2.1RowcardpEntrynot-accessiblecurrentA particular card protection which is created in using the boardTable of the Shelf MIB.
1.3.6.1.4.1.1038.130.40.2.1.1ColumncardpIndexread-onlycurrentcardpIndex = boardIndex in the Shelf Mib. This index points to the working board.
1.3.6.1.4.1.1038.130.40.2.1.2ColumncardpBoardFamilyread-onlycurrentThis field indicates the family of board concerned by the protection.
1.3.6.1.4.1.1038.130.40.2.1.3ColumncardpReliefIndexread-writecurrentA reference to the relief card. It must be an existing index in the boardTable of Shelf Mib. The relief card and the protected Card must below to the same fami…
1.3.6.1.4.1.1038.130.40.2.1.4ColumncardpTrafficStatusread-onlycurrentIndication of the protection switch position.
1.3.6.1.4.1.1038.130.40.2.1.5ColumncardpCommandread-writecurrentManual commands can be apply to the protection unit. The manual switch can be refused or cleared by equipment if a higher priority evenement is received or if …
1.3.6.1.4.1.1038.130.40.2.1.6ColumncardpStatusread-onlycurrentIndication of the current protection status