Initial version. This MIB provides external-alarm management and notifications
Imported Objects
PRVT-SWITCH-MIBswitch
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks
OIDNameAccessStatusDescription
1.3.6.1.4.1.738.10.5.112IdentityprvtDryContactsMIBInitial version. This MIB provides external-alarm management and notifications
1.3.6.1.4.1.738.10.5.112.0NodedryContactsNotifications
1.3.6.1.4.1.738.10.5.112.0.1NotificationstateChangedcurrentSend notification when operational status of the input changes
1.3.6.1.4.1.738.10.5.112.1NodedryContactsObjects
1.3.6.1.4.1.738.10.5.112.1.1TablecfgTablenot-accessiblecurrentA table containing inputs configuration and statuses
1.3.6.1.4.1.738.10.5.112.1.1.1RowcfgEntrynot-accessiblecurrentcfgEntry
1.3.6.1.4.1.738.10.5.112.1.1.1.1ColumnprvtAlarmIDaccessible-for-notifycurrentExternal and internal alarm index uniquely identifies this row. T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-conta…
1.3.6.1.4.1.738.10.5.112.1.1.1.2ColumnprvtSensorTyperead-onlycurrentSensor type. An enumeration with two values: input(1), output(2). T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-con…
1.3.6.1.4.1.738.10.5.112.1.1.1.3ColumnprvtNameread-writecurrentName of alarm. An OCTET-STRING with max. 16 OCTETS. Default value null string. Read-write
1.3.6.1.4.1.738.10.5.112.1.1.1.4ColumnprvtDescriptionread-writecurrentAlarm description. An OCTET-STRING with max. 64 OCTETS. Default value null string. Read-write
1.3.6.1.4.1.738.10.5.112.1.1.1.5ColumnprvtEnableStatusread-writecurrentSenging alarms status. An enumeration with two values: enabled(1), disabled(2). Default value is disabled(2). Read-write
1.3.6.1.4.1.738.10.5.112.1.1.1.6ColumnprvtAlarmStatusread-onlycurrentAlarm status. An enumeration with two values: no-alarm(1), alarm(2). Default value is no-alarm(1). Read-only.
1.3.6.1.4.1.738.10.5.112.1.1.1.7ColumnprvtAlarmSeverityread-writecurrentConfigured alarm severity. An enumeration with 4 values: info(1), minor(2), major(3) and critical(4). Default value is info(1). Read-write
1.3.6.1.4.1.738.10.5.112.1.1.1.8ColumnprvtPolarityread-writecurrentConfigured polarity. An enumeration with 2 values: normally-opened(1), normally-closed(2). This object is only for T-Metro 200 ES platform. Default value is no…
1.3.6.1.4.1.738.10.5.112.1.1.1.9ColumnprvtLastChangeread-onlycurrentThe value of sysUpTime at the time of the last operational status change. TimeTicks. Read-only